1. Place the enclosure on the pad The holes on the Coar Gouin enclosure must be aligned with the anchor hooks on the pad hardware not included This is a general representation of an enclosure mounted on a pad Configurations may vary Enclosure Wiring Grounding 1 Install and interconnect ground rods appropriate for proper grounding according to local electrical code requirements 2 Route ground wires from the ground system into the bus bar located on the enclosure Connecting Utility Power to the Enclosure CTEP G3 CTEP G6 amp CTEP GS8 have additional battery tray Site for Power Supply Tamper Switch optional Status Monitoring Lamp Present on all Models h P FAQadpaas NS A CEEE BBBBB ONO Myers Power Products CTEP G Manual Page 5 Electrical Input Output Box EIO o Ground Lug Euroblock Output Connection to Coax Duplex AC Utility Outlet Maintenance Bypass Switch Auxiliary Power Supply Connection To Power Supply AC Output Unlock and open the door of the enclosure Ensure that the utility power switch is OFF Install a high magnetic circuit breaker box a fe oe Using appropriate conduit connectors run wires from the utility breaker box to the receptacle box inside the enclosure Connect the wires to the receptacle and install it in the enclosure Turn breaker ON and verify the presence of incoming
2. Products CTEP G Manual Page 11 Battery Enclosures Power Supply Shelf Locate the power supply on the power supply shelf and connect the battery cable to the EM Power Supply on CTSP Battery Connection Black Red Connectorized Cables from battery tray s Myers Power Products CTEP G Manual Page 12 Chapter 3 Service and Contact Information Myers Power Products makes every effort to ensure parts and equipment arrive in working condition Occasionally it may be necessary to return parts or equipment that are not in working condition If the unit requires service please follow these steps 1 Contact Myers Technical Customer Service by telephone at 610 868 5400 Monday Friday 8AM to 5PM U S Eastern time Sales and Accounting issues use 610 868 3500 Note the product model number the serial number and the date purchased if known If you call Myers Customer Service a technician may ask you to describe the problem and try to solve it over the phone If this is not possible the technician will issue a Returned Material Authorization Number RMA If the product is under warranty repairs are free If not there is a repair charge Procedures for servicing or returning products may vary internationally Contact Myers Power Products for country specific instructions 2 If possible pack the product in its original packaging If the original packaging does not exist pack the product carefully with suffic
3. AC at the Duplex AC Utility Outlet Route the hardline coax to the rear of the enclosure near the coax bushing Install a pin connector onto the coax hardline SS St a aa Insert the pin of the pin connector into the rear of the coax bushing and secure the connecter per the manufacturer s instructions 10 Inside the enclosure trim the pin connector so that it is about a 1 2 inch long 11 Slide the open side of the Euroblock connector over the pin and tighten the Euroblock screw securely onto the stub of the pin connector 12 Refer to the CTSP EM User Manual for detailed installation instructions regarding the Interface Harness to connect the Status LED Tamper Switch if present and the Battery Thermal Sensor Myers Power Products CTEP G Manual Page 6 Optional Fan Kit CTE FAN KIT An optional enclosure exhaust fan can be added to provide additional enclosure ventilation The power supply output is used to power the fan Note Although the fan is marked rated for 120VAC it will work fine in this application from 60 to 87 VAC Installing the fan kit is straightforward 1 Remove the existing vent baffle 1f present Keep all hardware Remove screws holding vent baffle in place Coax Bushing Elo with bypass switch Vent Baffle Grp 27 or 31 Grp 27 or 31 Grp 27 or 31 Top Terminal Top Terminal Top Terminal Battery Battery Battery Battery Drawer w slides 2 Replace ve
4. Power Products Broadband CTEP G Series Three Six Battery Pole Ground Mount Enclosures Four Eight Battery Pole Mount Enclosures 120 V 240V User Manual oD OODDDBODBBS PPPD amp AS Power Products DODDD BoSsos gt Myers Power Products CTEP G Manual 6 2009 Chapter 1 General Information The Myers Pwer Products Myers CTEP G Series Power Supply Enclosures provide protection for power supplies UPS and for batteries for broadband cable operations Safety This Safety Guide contains important instructions that should be followed during installation and maintenance of the Myers equipment and batteries It is intended for Myers customers who setup install relocate or maintain this type of equipment Only trained service personnel should install and maintain the power supply enclosure Changes and modifications to this unit not expressly approved by Myers Power Products could void the warranty Failure to observe these warnings may result in serious injury death or damage to the equipment Electrical Do not work alone under hazardous conditions Warnings Do not handle any metallic connector before the power has been disconnected Servicing this equipment may require working with protective covers removed and utility power connected Use extreme caution during these procedures High current through conductive materials could cause severe burns When groun
5. TEP G8 Six 15 black battery jumpers One long black jumper One long red jumper One long connectorized red and black cable Myers Power Products CTEP G Manual Page 3 Installing the Enclosure Models may vary in appearance from those depicted below Install the Mounting Bracket on a Pole The pole side portion of the Mounting Bracket can be either bolted or banded to the pole CTEP4 models CTEP3 CTEP6 CTEP8 models Note the slots to band mount the bracket Install the Enclosure on the pole side Mounting Bracket Attach but do not tighten the bolts nuts and washers on the pole side mounted bracket prior to installing the enclosure Leave enough bolt space exposed so the enclosure side portion of the mounting bracket can hang on the bolts Enclosure side portion of Mounting Bracket is permanently attached to the enclosure Carefully lift the enclosure onto the pole side of the Mounting Bracket Ensure that all the bolts are engaged by the bracket Once the enclosure is properly hung securely tighten all the bracket bolts Myers Power Products CTEP G Manual Page 4 Ground Mount Installation 1 Installation on a Myers approved concrete pre cast pad is recommended A variety of pads are available Contact Myers for additional information 2 Secure the enclosure to the pad Refer to the diagrams below Service Entrance Load Center For all ground mount enclosures Coax Housing
6. ding cannot be verified disconnect the equipment from the utility power outlet before installing or connecting to other equipment Reconnect the power cord only after all connections are made Check that the power cord s plug s and sockets are in good condition Replacement of fuses or other parts must be with identical types and ratings Substitution of nonidentical parts may cause safety and fire hazards Battery Always replace batteries with same or equivalent type recommended by the Warnings manufacturer Danger of explosion if battery is incorrectly connected or replaced Batteries present a risk of electrical shock and burns from high current in the event of a short circuit Observe proper safety precautions Dry Batteries must be recycled Deliver the battery to an appropriate recycling GY facility or ship it to the supplier in the new battery packing material Overhead Never stand underneath a unit while it is hoisted Always wear a hard hat Warnings Lifting Warnings Modules are heavy Use proper lifting techniques and equipment to avoid injury Myers Power Products CTEP G Manual Page 1 Chapter 2 Installation Prior to installing the power supply enclosure a utility breaker box must be installed on the pole Utility line voltage must be routed to the enclosure Local state federal and or National Electric Code NEC regulations regarding location permits and electrical wiring must be adhered to Do not operate the po
7. ient padding Pack the unit properly to avoid damage in transit Never use Styrofoam beads for packaging as the static electricity that is generated may damage electronics Damage sustained in transit is not covered under warranty Mark the RMA on the outside of the package Return the unit by insured prepaid carrier to the address given to you by Customer Service manufacturer in the replacement battery packing material aS A Be sure to deliver spent batteries to a recycling facility or ship to the Myers Power Products contact information Technical 610 868 5400 Myers Power Products Inc Sales Accounts 610 868 3500 2000 Highland Ave Monday Friday Bethlehem PA 18020 SAM to 5PM US Eastern Myers Power Products CTEP G Manual Page 13 Limited Warranty Myers Power Products Inc Myers warrants this product to be free from defects in materials and workmanship for a period of two 2 years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products To obtain service under warranty you must obtain a Returned Material Authorization RMA number from customer support Products must be returned with transportation charges prepaid accompanied by a brief description of the problem encountered This warranty does not apply to equipment that has been damaged by accident negligence misapplication or has been altered or modified i
8. n any way This warranty applies only to the original purchaser EXCEPT AS PROVIDED HEREIN MYERS MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL MYERS BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically Myers is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise Entire contents copyright 2009 by Myers Power Products Inc All rights reserved Reproduction in whole or in part without permission is prohibited Myers Power Products CTEP G Manual Page 14
9. nd battery string is wired per the diagram below Route wires between the battery Connect Long Red Jumper drawers in space behind drawers to of Battery 4 on top battery shelf AAA Connect Long Black Jumper to of Battery 1 on top battery shelf Black Battery Jumpers Battery Drawer Bottom Battery Tray Enclosure Front Myers Power Products CTEP G Manual Page 10 4 Battery Enclosures Alternate Positioning Battery Shelves Note Following the SCTE HMS standards the battery with the main output power supply lead connected to the negative terminal is always Battery 1 Black Battery Jumpers Connectorized Red Battery Drawer wire to Power Supply Upper or Power Supply Shelf Route wires thru hole in Upper Shelf Connectorized Black wire to Power Supply Enclosure Front 8 Battery Enclosures Alternate Positioning Battery Shelves Wire the top battery tray to the upper power supply shelf as the 4 battery enclosure The bottom battery tray that is holding the second battery string is wired per the diagram below Route wires between the battery drawers in space behind drawers Connect Long Black Jumper to of Battery 1 on top battery shelf Connect Long Red Jumper to of Battery 3 on top battery shelf Battery Drawer Black Battery Jumpers Bottom Battery Tray Enclosure Front Myers Power
10. nt baffle with the fan assembly Secure the fan assembly with screws Route the wire from the fan to the rear of the enclosure towards the enclosure ground lug and coax bushing Use the provided wire ties to secure the wire to the rear of the enclosure Route fan wire to rear of enclosure place end near coax bushing Install fan assembly and replace screws Coax Bushing EIO with bypass switch N Fan Assembly Myers Power Products Grp 27 or 31 Top Terminal Battery Grp 27 or 31 Top Terminal Battery Grp 27 or 31 Top Terminal Battery Battery Drawer w slides CTEP G Manual Page 7 3 The fan must be connected to the power supply output to operate NOTE If the power supply in this enclosure is already powering the network this step requires that the network be temporarily powered down Before proceeding ensure that the power supply is OFF by unplugging it from AC utility power and by switching the battery breaker on the EM to OFF Remove the Euroblock connector from the EIO output wire Ensure that the fan wire has about a 2 inch of insulation removed from the end of the wire Pair the bare wire end of the fan wire with the bare EIO wire and reinsert both into the Euroblock and securely tighten the screw onto both wires Attach the other fan wire to the enclosure ground lug The fan will now operate once the power supply has been installed To enclosure fan assembly Thermostat c
11. ontrol for fan Factory set for fan turn on at 120F Adjust if desired Remove EIO output wire from connector Reinsert both EIO wire with fan wire Tighten the Euroblock screw onto both wires Ensure Euroblock screw is tight 4 The thermostat is located to the left of the fan on the fan assembly The fan is thermostat controlled and should be pre set to turn the fan on at approximately 120 degrees F 50C If desired the thermostat can be adjusted to change the fan turn on temperature Other Options An optional External AC Generator Interface is available for the following models CTEP3 120GI CTEP4 120 240GI CTEP G6 120GI CTEP8 120 240GI Additional options are available For a list of these options please contact Myers Power Products Myers Power Products CTEP G Manual Page 8 Connecting the Batteries Remove the battery connection from the EM prior to battery installation Use normal precautionary measures when wiring and connecting the batteries Placement of batteries is for suggestion purposes only The battery placement and hookup may be different for your system Please consult with your management Tape one end of each jumper cable prior to installation Qa Attach the bare end first then carefully untape and attach the other end 3 Battery Enclosures Battery Shelves Note Following the SCTE HMS standards the battery with the main output power supply lead connected to the negative terminal is al
12. ways Battery 1 Black Battery Jumpers Battery Drawer Connectorized Red wire to Power Supply Upper or Power Supply Shelf Route wires thru hole Connectorized Black in Upper Shelf wire to Power Supply Enclosure Front 6 Battery Enclosures Battery Shelves Wire the top battery tray to the upper power supply shelf as the 3 battery enclosure The bottom battery tray that is holding the second battery string is wired per the diagram below Route wires between the battery drawers in space behind drawers a Connect Long Black Jumper to of Battery 1 on top battery shelf Connect Long Red Jumper to of Battery 3 on top battery shelf Black Battery Jumpers Battery Drawer Bottom Battery Tray Enclosure Front Myers Power Products CTEP G Manual Page 9 4 Battery Enclosures Battery Shelves Note Following the SCTE HMS standards the battery with the main output power supply lead connected to the negative terminal is always Battery 1 Black Battery Jumpers Battery Drawer Connectorized Red wire to Power Supply Upper or Power Supply Shelf Route wires thru hole in Upper Shelf Connectorized Black wire to Power Supply Enclosure Front 8 Battery Enclosures Battery Shelves Wire the top battery tray to the upper power supply shelf as the 4 battery enclosure The bottom battery tray that is holding the seco
13. wer supply where the temperature and humidity are outside the specified limits See Specifications in this manual Base Models Supported this list is not exhaustive please contact Myers for a complete listing Myers Power Products CTEP G Manual Page 2 Specifications Environmental Specifications Physical Specifications Characteristic Specification Height X Width X Depth CTEP3 30 x 24 x 16 76 x 61 x 41 cm CTEP4 27 x 29 x 18 67 x 72 x 45 cm CTEP6 39 x 24 x 16 99 x 61 x 41 cm CTEP8 39 x 29 x 18 99 x 72 x 45 cm Height X Width X Depth CTEG3 38 x 24 x 16 97 x 61 x 41 cm CTEG6 47 x 24 x 16 119 x 61 x 41 cm CTEG8 47 x 29 x 18 119 x 72 x 45 cm Weight CTEP G3 50 Ibs 23 kg CTEP4 78 Ibs 34 5 kg CTEP G6 77 lbs 35 kg CTEP8 140 Ibs 63 6 kg Unpacking Inspect the unit upon receipt Notify the carrier if there is damage The packaging is recyclable save it for reuse or dispose of it properly Check the package contents The package contains the enclosure battery cables connectors and associated hardware and product documentation CTEP G3 Two 15 black battery jumpers One long connectorized red and black cable CTEP G6 Four 15 black battery jumpers One long black jumper One long red jumper One long connectorized red and black cable CTEP4 Three 15 black battery jumpers One long connectorized red and black cable C