1. As energy export increases and decreases the E R S is continually reacting to this change by varying the amount of power supplied to the heating load This is indicated by the Power Bar which moves from left to right according to how much power the E R S is diverting The display is updated every 2 seconds As the Power Bar steps increase the live export reading on the top line decreases depicting the movement of recovered energy from the grid to the heating load Each step represents 5 of the total heating load e g 5 of 3kw load 150w steps When E R S is recovering energy during the day it will always leave a small amount of export to ensure inadvertent import does not occur During the night E R S will display the live imported energy of the building in kW The power bar will be empty indicating that E R S is not powering the heating load CONTROL ELEMENTS Boost OFF Button Home Screen Boost ON Button Home Screen Menu Button Home Screen Enter Menu Start Manual Boost Stop Manual Boost Menu Screen Menu Screen Menu Screen Exit Menu Up change setting Down change setting Enter Backlight Button Home Screen backlight OFF Turn on backlight Home Screen backlight ON Display kWh Meter Navigation Overview Button Functions when on the Home Screen Use the Enter Button to scroll through the menu options and the arrows to change the option settings Enter Backlight pu
2. POWERFLOW Made in England technology Energy Recovery very Sys stem Energy Recovery System E R S 4 0 Silver Edition User Guide D KD Thank you for supporting us by purchasing a PowerFlow Energy Recovery System You now own the fastest reacting most advanced export energy controller on the market today The PowerFlow E R S is a fully automated intelligent device that manages the recovery of exported energy from a solar or wind renewable generation system No user input is required for ERS operation other than the manual override should you wish to boost your heating device The main purpose of this guide is to explain how the user interface operates Please pay particular attention to the Legionella advice on the back page For your peace of mind PowerFlow E R S and F POINT technology have been independently tested in association with the University of Gloucestershire to ensure regulatory compliance Please read this user manual carefully before commencing operation Further information can be found at www powerflowenergy com PRODUCT OVERVIEW F POWERFLOW ERS 4 0 ERS4XXXXXXX Device Identification Plate Main Power Switch 3 positions E R S ON forward position E R S OFF centre position E R S BYPASS back position Model Number Serial Number ie Data Port Mains Power Power Flow E R S 4 I Connector PUE EEr aoe L Ltt l Output Voltage 240V Maximum Curent 208 e P
3. OWERFLOW Auxiliary Single Pha PS ation Only Connection MENU Device Fuse Ss LA C 208 Max Site g aenn NL 20A Max aS ENT WMA Sis esl Current Clamp Connection Manual Boost ON Manual Boost OFF Enter amp Backlight LCD Display Menu button button LCD DISPLAY ICONS Home Screen Energy Flow Direction Arrow House Icon National Grid Icon Live Import Export Power Reading Load Power Icon Output Power Bar Manual Timer Icon LCD Display Updates Every 2 Seconds IMPORT EXPORT DISPLAY OPERATION National Grid Icon Energy Flow Direction Arrow House Icon Live Import Export Power Reading The top line of the LCD display shows live information about changes in the amount of power being imported from or exported to the National Grid The energy flow direction arrow changes pointing from the grid icon to the house icon when the building is importing energy and from the house icon to the grid icon when the solar generator is exporting energy The numerical value of the live energy import or export dependent on the direction of energy flow in kilo Watts kW is displayed opposite In the example above the building is exporting 2 254 kW to the national grid The import export power reading is accurate to 3 decimal places POWER OUTPUT DISPLAY OPERATION Load Power Icon Manual Timer Icon Power Bar s we LS The bottom line of the LCD display shows live information about the power output to the heating load L
4. peating until the temperature is lowered If the message remains please contact your installer in the first instance ERS does not switch ON Ensure ERS is switched off at the main switch before commencing Check the fuse The fuse is located on the left hand end of the device Push in the fuse cap and twist anticlockwise to remove How can an external timer be The Aux connector on the right hand panel of ERS is used for the external timer connection Accessory connected product AUXCONN is required for this feature How can the smart relay The Aux connector on the right hand panel of ERS is used for the smart replay connection Accessory function be used product AUXCONN is required for this feature How does the manual boost Pressing BOOST ON will override ERS at any time and switch the heating device on to full A countdown function work timer will appear After the timed period has completed ERS will revert to normal operation The timed period can be adjusted in the menu under boost time from 10 120 minutes How is the display Hold the back light button down for 1 second the display will illuminate for 5 minutes illuminate How can the total savings be Whilst on the home screen with the back light illuminated see above press the Back Light Enter button viewed again The display will show the total savings counted in kWh s Press the Back Light Button again to return to the home screen Where can I find more information if my ques
5. sh once Enter Backlight push Twice Menu N a Manual Boost ON gt Manual Boost OFF gt Menu Screen Next screen Button Operation Push and hold buttons for 0 5 seconds before release Boost Time 10 120 minutes default 90 minutes Smart Boost Function Enable Disable default Disable Enabled Export time 1 8 hours External Timer Enable Disable default Disable default 4 hours Smart Relay Function Enable Disable default Disable ACTION Start Manual Boost Override E R S control count down timer displayed ACTION Stop Manual Boost Revert to E R S control ACTION Turn backlight on 2 minute time out ACTION When back light is lit Displays total savings kWh meter total recovered energy What does LOAD OFF mean When LOAD OFF is displayed the connected electrical device ERS is powering has switched off This may indicate for example that the water is hot and the thermostat on the device has opened What does ERS has an internal temperature sensor for safety which is triggered at 60 C If this message is displayed INTERNAL TEMP TOO HIGH firstly check the ventilation of the unit to ensure there is adequate space around all sides If the over mean temperature message is displayed ERS will automatically reset its self after 2 minutes If the over temperature condition continues the reset process will keep re
6. t this risk is controlled Adequate water exchange and or additional heating must be supplied in order to raise the water temperature above 60 C on a minimum of a weekly basis This can be achieved in all electric homes by using the external timer function to override the ERS system once per week Further advice on Legionella can be found at www hse gov uk legionnaires If you have technical problems please contact your installer in the first instance The following information will be required in order to provide you with the necessary assistance e ERS Model Number e ERS Serial Number e Type and number of heating elements connected e Location of ERS unit within the building PowerFlow Energy Ltd Barrs Court Netherwood Road For Support please email us CN Rotherwas Industrial Estate Herefordshire Email info powerflowenergy co uk HR2 6JU United Kingdom www powerflowenergy com Pr ERS eT
7. tion Please visit www powerflowenergy com for more service information is not listed here IMPORTANT SAFETY INFORMATION Caution Please take note of the following 1 Risk of burns due to hot enclosure During operation the ERS enclosure may become hot to touch Always use caution when touching the enclosure after long periods of operation 2 DO NOT place objects over the enclosure PowerFlow ERS uses the metal enclosure to dissipate heat Covering the enclosure may cause product failure Please ensure adequate ventilation is provided For further information refer to the installation guide 3 DO NOT disassemble the ERS unit at any time PowerFlow ERS contains live parts inside never disassemble the system Important Legionella Advice Legionella is a bacteria that can grow in water below 60 C It is common practice for hot water and heating systems to raise the water temperature on a weekly basis over 60 C in order to kill any bacteria growth Due to the very nature of ERS it is possible during periods of low energy export to partially heat the water In systems without a second heating source such as a boiler to top up the water temperature it is possible that unused warm water could remain in a temperature range where bacteria can grow Because the particulars of each installation are different PowerFlow Energy cannot take responsibility for controlling the risk of legionella It is the installers responsibility to ensure tha

Download Pdf Manuals

image

Related Search

Related Contents

  Verriegelungseinheit „SuperLock“ für HSK-Spannsysteme  Black Box LWE100A-KIT-W1 User's Manual  Lenovo IdeaPad G40-30  MELSEC-L Analog-Digital Converter Module User`s Manual  AA 300 AA 400 AA 300 FC AA 400 FC AA 300 B AA 400 B  Section 230900 - Instrumentation and Controls    Integral IN2T4GEXBFXK2 memory module  Firefriend BQ-6850 barbecue  