Home
USER`S MANUAL - MARUSON Technology
Contents
1. SmartNet 750 1000 1500 2000 LCD 1 Inspection The following items are inside the box Users Manual UPS Power Cord RJ11 Cable USB Cable Software CD Warranty Card Equipment Protection Policy Remove SmartNet UPS from its package and inspect it for damage If any damage is discovered re pack the unit and return it to the place of purchase 2 Placement of UPS Provide 7 8 inch clearance on sides for adequate airflow around the unit when placing beside a monitor Avoid direct sunlight Avoid excessive heat Avoid excessive humidity or liquids Avoid excessive dust pa UPS Indicators and Controls Power Switch dy Power Switch Press and release the button to supply power to the Battery Power Supplied Outlets Press and release the button again to switch off power to the Battery Power Supplied Outlets LCD panel Ay AC MODE lo OVER LOAD f _ Load Level Input voltage Output voltage AC mode indicator Load level Overload indicator USER S MANUAL 3 Connect UPS to Utility Use the power cord that came with your UPS to connect the UPS directly to the wall outlet Do not power the UPS using a surge Suppressor or power strip Battery Charging The UPS battery charges whenever the UPS is connected to utility power and typically requires less than 6 hours to charge fully Operating runtim
2. d Overload Protection AC Surge i 7 Full time 750 joules Protection Phone fax DSL RJ11 RJ45 One In One Out PROTECTION Network Surge Dimension 13 8 x 5 7 x6 3 in 15 6 x 5 7 x8 1 in PHYSICAL DxW xH Net Weight 18 31 lbs 19 8 lbs 25 6 lbs 27 lbs Operatin p g 0 40 C 0 90 Relative Humidity non condensing ENVIRONMENT Environment Noise Level Less than 45dB Less than 55dB Windows 2000 2003 XP Vista 2008 Windows 7 Linux INTERFACE USB amp RS 232 Unix and MAC Specification may change without notice Product Warranty and Service Information For U S customers please register your product at www MarusonUSA com For international customers please contact your local authorized distributor or e mail CustSrv MarusonUSA com for assistance Maruson Technology Corporation MARUSON 18557 E GALE AVE CITY OF INDUSTRY CA 91748 P O Box 1986 Walnut CA 91788 USA Toll Free 1 888 MARUSON TEL 1 626 912 8388 FAX 1 626 912 8680 E mail Custsrv MarusonUSA com Web Site www MarusonUSA com
3. e is reduced until the battery is fully charged 6 hours 4 Connecting Equipment to UPS Connect the equipment to Battery Power Supplied outlets Battery Power Supplied Outlets 8 Connect computer monitor and external drive to the Battery Power Supplied outlets These outlets provide battery backup EMI filtering line conditioning and surge protection Battery power is automatically provided in case of power failure Beware of the Power Switch It must be kept in the ON position otherwise the UPS will be disabled and your equipment will not be protected during a power failure ce 3 G3 oT N g G amp A s i o m S ZZE Batt Level if Battery mode indicator Battery level Low battery indicator Fault indicator u E 5 Connect Modem Phone Line Network SmartNet UPS protects a single line 1 in 10ut phone modem or fax machine from surges when connected through the UPS Plug in connecting internet line into the IN socket Use one more internet line cable in the OUT socket and plug one other end to the modem input socket 6 Connect UPS to Computer Connect one end of the USB RS 232 cable to the PC and the other to the USB RS 232 port at the rear of the UPS Insert ViewPower software CD or download the latest version of ViewPower software from http Awww power software download com to your hard drive Foll
4. l codes In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit This unit is intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes and may be toxic A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hands 2 Use tools with insulated handles 3 Wear rubber glove
5. ow on screen instructions to complete the software installation Once PC is restarted ViewPower is geared and presents as an orange plug icon located in the system tray at the bottom right corner 7 Turn On Off To turn onthe UPS unit press the power On Off Switch once To turn off the UPS unit press the Power On Off Switch again 8 Storage To store the UPS for an extended period cover it and store with battery fully charged While in storage recharge the battery every 3 months to secure battery life Panel Information RS 232 USB Port Circuit Breaker Network Modem Phone Line Surge Protection Battery Power Supplied Outlets RS 232 USB Port Network Modem Phone Line Surge Protection Battery Power Supplied Outlets Circuit Breaker USER S SmartNet 750 1000 1500 2000 LCD Safety Caution SAVE THESE INSTRUCTIONS This manual contains important instructions for the SmartNet Series that should be followed during installation and maintenance of the UPS and batteries This UPS utilizes voltage that may be hazardous Do not attempt to disassemble the unit The unit contains no user replaceable parts Only factory service personnel may perform repairs Internal battery voltage is 12Vdc Sealed lead acid 6 cells battery Connection to any other type of receptacle other than a two pole three wire grounded receptacle may result in shock hazard as well as violate local electrica
6. s and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminal Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same number and type of sealed lead acid battery The maximum ambient temperature rating is 40 C During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible Battery Recycling Information UPS contains non spillable sealed lead acid batteries On the battery you will find the battery name Please refer to the chart below for recycling information or contact your local distributor for assistance Ba
7. ttery Name Recycling inside the USA Recycling outside the USA RITAR Batter 800 273 8599 N A a MARUSON UPS SYSTEMS Trouble Shooting Possible Cause Solution No words display Low battery Charge battery up to 6 hours panel type of battery on turn on the UPS Alarm The UPS is overload Remove some loads first Before continuously reconnecting equipment please sounds when the verify that the load matches the mains is normal UPS capability specified in the specs When power fails The UPS is overload Remove some critical load back up time is Battery voltage is too Charge the UPS at least 6 hours shorten low Battery defect It might Replace the battery with the same be due to high type of battery temperature operation environment or improper operation to battery The mains is Power cord is loose Reconnect the power cord properly normal but the unit is on battery mode f any abnormal situations occur that are not listed above please call for service immediately Specification 750LCD 1000LCD 1500LCD 2000LCD 480 W 700 W 1050 W 1400 W Voltage INPUT Voltage Range 81 145VAC or 162 290VAC Frequency 50 60Hz Auto Sensing Frequency Regulation 50Hz or 60Hz 1 Hz Waveform x2 x2 BATTERY Backup time A to 40 p to 60 ep to 85 minutes minutes minutes minutes Recharge Time TRANSFER TIME Protection EMI RFI Filter Full time AC Input Circuit breaker Full Protection Overcharge an
Download Pdf Manuals
Related Search
Related Contents
Samsung Micro-ondes Solo, 28L, Blanc - MS28F301EAW Anleitung des M027 - als PDF - KC-Club PR-200NE取扱説明書(PDFファイル) Fiche Technique Tour de surveillance mobile avec pare Breville BTS200 Slow Cooker User Manual Lovibond® Water Testing Samsung SGH-F488I User Manual Quattro 4.0 LITE User Guide Sikafloor Copyright © All rights reserved.
Failed to retrieve file