Home
Manual - Catering Equipment Supplier
Contents
1. 185435 ECN3461 11 SERVICE INFORMATION For help with the installation maintenance and use of your Lincat equipment please contact our service department T UK 01522 875520 All service work other than routine cleaning should be carried out by one of our authorised service agents We cannot accept responsibility for work carried out by other persons To ensure your service enquiry is handled as efficiently as possible please tell us Brief details of the problem Product code Type number From serial plate beside dispensing tap Serial number Lincat reserve the right to carry out any work under warranty during normal working hours Monday to Friday 08 30 am to 17 00 pm GUARANTEE This unit carries a comprehensive UK twelve month warranty The guarantee is in addition to and does not diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the instructions in these instructions Consumable items Damage due to incorrect installation modification unauthorised service work or damage due to scale The manufacturer disclaims any liability for incidental or consequential damages IS435 ECN3461 12 IS435 ECN3461 This page intentionally left blank
2. Lincat User and Installation Instructions Wall Mounted Water Boiler WMB3F B and WMB3F W Please make a note of your product details for future use Date Purchased Model Number Serial Number Dealer 1S435 ECN3461 AOI MI RK L L A ear Customer hank you for purchasing this Lincat product ith correct use and careful maintenance as described in these instructions your Lincat roduct will give years of trouble free use We produce over 450 different items of catering equipment and our range is constantly being extended and improved Find out more about Lincat products from your local distributor or CONTENTS CONTENTS enron yaaa aee E AT e e re EARTE E aE E a ESk 2 SAFETY INFORMATION panie atiina aia e a cele ll 3 DELIVERY CHECKS Deich ionene a E a EEEE a 4 TECHNICAL SPECIFICATION ssossssesieseeeieseereseinressrnsterrnsrerrnsserrnsternnsteeneenne 4 ACCESSORIES erani ea E E EE hee AEE T 4 INSTALLATION tee eta les aie ea E E AT eyes 4 OPERATION sl nce 8h er adler eat a A a a a a e taal e a 5 C FANN G ac SNR a a A O 8 MAINTENANCE zaii att E e EE SET AE EAS 9 DIAGNOSTIC MESSAGES ensien a E a ARE REE 11 SERVICE INFORMATION sick sateen ea ee ene a a 11 GUARANTEE Eemonienarun araga a A a a a a 12 185435 ECN3461 A FA 4 AN SAFETY INFORMATION To prevent injury to yourself or your staff and to avoid damaging the product please read and fo
3. 3 Fit the outer cover and turn on the boiler 185435 ECN3461 10 DIAGNOSTIC MESSAGES The control panel displays messages and information that can help with fault diagnosis Before calling for service draw off a litre of water clear the fault code by pressing the Fn button and turn the boiler off and on again at the mains supply If the fault persists call the service department for advice Message Displayed Possible cause Corrective action FILTER DESCALE Scale on level sensors e Descale Boiler overfilling e Check water inlet I CAUTION valve SEE MANUAL STADE CLEAR FILTER HO WATER Water turned off e Check water Inlet hose bent or blocked aad and drain FAULT Water pressure too high i eiia SEE MAHUAL or low e Call service if fault Drain valv n PeiPieis STANDBY CLEAR Se ees Boil dry overheat e Isolate the unit FILTER HOT HEAT IHG protector tripped wait for 30 Temperature sensor fault minutes then turn FAULT Element failed i ne POB Taul connections STANDBY CLEAR Faulty loose connection Call service if fault persists Temperature set too high e Reduce Dee OWER TEMP Temperature sensor fault temperature Boiler not fillin Setllaganestly FAULT SL again Excessive scale in tank e ed SEE MANUAL e Call service if fault PCB fault persists STADE CLEAR FILTER TMERMISTOR Temperature sensor fault e Call service cc i FAULT m SEE MANUAL STAHDE
4. een contrast can be adjusted as required The boiler is designed to be left permanently switched on it is only necessary to turn it off for descaling or maintenance Changing water temperature screen backlight and contrast 1 2 Turn power off at the wall for 5 seconds and then turn on again When the Filter Flow screen is displayed press and hold the power button until the software version is displayed Press Fn and the temperature will be displayed Press the power button to cycle through the values 70 to 96 deg C Press the Fn button to select the required value The backlight adjustment screen is displayed next Press the power button to cycle through the values 1 to 25 Press the Fn button to select the required value The contrast adjustment screen is displayed next Press the power button to cycle through the values 35 to 60 Press the Fn button to select the required value Press the power button to exit Standby If the boiler is to be left unused for a long period the element can be turned off by pressing the power button 1S435 ECN3461 Filter replacement The FILTER display shows the estimated remaining life in the current filter cartridge When the filter needs replacing a reminder message is displayed This is followed by the change filter screen FILTER READ CHANGE FILTER STAMOBY CLEAR The boiler can be used without a filter but scale may build up m
5. llow the safety precautions below before setting up and using the unit Remove all plastic coatings and clean the unit before use Always isolate the unit from the electricity supply before servicing This unit must be earthed Do not try to modify this unit Never clean the unit with a water jet or steam cleaner This unit is not suitable for outdoor use Inform staff that the outer surfaces will become hot Keep these instructions in a safe place near the unit for future reference 185435 ECN3461 DELIVERY CHECKLIST If an item is missing please contact your dealer immediately e Electric water boiler e User instructions e Guarantee card e 44mm diameter rubber grommet Note No supply cable or connection hose is supplied with this unit TECHNICAL SPECIFICATION Model WMB3F Width mm 300 Depth mm 185 Exc tap Height mm 415 Power Rating kW 3 0 Net weight empty kg 8 5 Net weight full kg 14 5 Ambient temperature C 5 to 30 Water inlet pressure Bar 1 to 8 OPTIONAL ACCESSORIES Replacement filter cartridge FCO2 Drip tray DR72 MECHANICAL INSTALLATION The boiler must be installed on a vertical surface with the base in a horizontal position ina location where it can be supervised by trained personnel Ensure that the location it is fitted in is frost free WARNING The unit must be installed on a solid concrete brick wall by a qualified fitter Lincat does n
6. ore quickly and water taste may be affected Replace the filter as follows 1 Twist the base of the filter 90 degrees to the left and carefully lower the filter cartridge out of the unit It will contain a small amount of water 2 Remove the black cap and place on the new filter 3 Insert the filter fully into its recess and twist to the right to lock in place 4 Press and hold the Fn button for 10 seconds to reset the filter life monitor 5 Drain off approximately 3 litres of water to remove any loose carbon particles from the filter CLEANING Clean the external surfaces of the unit regularly to maintain hygiene Wipe the dispensing tap daily to remove any limescale deposits and check that the water outlet is clear Wipe the unit down with a damp soft cloth Do not allow excess water to run into the unit Do not use abrasive creams or scourers 1S435 ECN3461 8 MAINTENANCE Filter Twist to the left and remove See section on filter replacement Descaling The descaling procedure must be performed by trained personnel as it requires the removal of panels from the boiler and access to live electrical components The boiler should be descaled regularly to maintain efficient operation and water quality The frequency depends on the hardness of the local water and the timely replacement of the filter The boiler is best descaled at the end of the working day to allow the descaling agent several hours to wo
7. ot accept any responsibility for the safety of any unit not installed this way Use the template provided S436 to mark the position of the 3 mounting holes Drill the wall and insert suitable wall plugs Remove the glass front outer body of the boiler Loosen the screw holding the lower centre trim slide the trim forward re tighten the screw Remove the screw in the top of the boiler Lock open the drain tap Carefully slide the the glass front and metal sides upwards and away from the unit Secure the boiler to the wall using 5mm 10g screws IS435 ECN3461 4 ELECTRICAL INSTALLATION For safety regulations the plug or means of disconnection must always be accessible This boiler must be earthed Check that the voltage of your electricity supply corresponds to the voltage shown on the serial plate The boiler is supplied with a terminal block suitable for flexible wires upto 6mm Connection wires may either be threaded through the cutout in the back panel or via a suitable 20mm diameter glanded bush in the unit base After removing the smaller of the two knock out panels marked B Connection sequence is as detailed below E Earth Green Yellow Right terminal N Neutral Blue Centre terminal L Live Brown Left terminal WATER INSTALLATION Connection hoses may either be fed through the cutout in the back panel or via the larger of the two knock out panels in the unit base marked A A blank rubber grommet is su
8. pplied and should be cut to fit around the feed pipe and fitted into the unit base to seal it The inlet connection point on the inlet solenoid valve is 4 BSP and should be connected to the mains water supply via an accessible isolating tap Connect the condesate overflow pipe to a suitable drain considering any applicable local water regulations If required the internal pipe may be disconnected from the external connector and the pipe extended to pass through the cutout in the back panel and connected to a suitable drain Turn on the water supply to check that there are no leaks Refit the outer cover 1S435 ECN3461 5 OPERATION Layout of components a 2 Key a 1 Power Button 3 2 Fn Button AN 3 Filter A 4 Knock out for water Jax 5 Knock out for power ok 6 Grommet for tank drain 7 Overflow pipe 1S435 ECN3461 First use Switch on the mains water supply and the electricity supply Leave the boiler for 15 minutes to allow it to fill completely Drain off approximately 3 litres of water to remove any loose carbon particles dislodged from the filter Regular operation The boiler starts automatically when the mains electrical supply is turned on After a short delay the unit fills with water and heats During the heating cycle small quantities of water are added to ensure that hot water is always available at the tap The water temperature screen backlight and scr
9. rk Lincat recommends its own descaling agent available from Lincat spares department part code MS19 on A OUO N 11 185435 ECN3461 Wear protective clothing Isolate the boiler from the electricity supply Turn off the power and let the water cool to approximately 60 C to avoid injury Remove the screw on the top of the boiler and slide off the body Remove the insulation on top of the tank then unscrew and remove the tank lid Add the descaling agent a little at a time as some types can cause hot water to erupt Always follow the manufacturer s instructions Replace the tank lid and outer body and attach an Out of Use notice to the boiler to prevent use during descaling Turn on the electricity and allow the boiler to heat and run normally for approximately 30 minutes Isolate the boiler and allow the water to cool Remove the outer body and tank lid and inspect the tank and level sensor housings for scale deposits If necessary repeat the descaling process Drain and flush all descaling agent from the tank completely as follows i Unscrew the drain plug Use a 24mm spanner to hold the plug and a 21mm socket on a ratchet to remove it from the bottom of the tank to drain all the water out DETAILA ji Flush out the tank with clean water iii When empty replace the drain plug and replace the cover 12 Replace the tank lid ensuring that the gasket is sealing the top of the tank correctly 1
Download Pdf Manuals
Related Search
Related Contents
Manuel GreenBox 8000E ABRIL de 2011 取付説明書 テグランネオ タイル編(現場張り仕様) SECO-LARM USA E-920A User's Manual United Digital Technologies NDC-455V09-22P surveillance camera RedBeam Check In/Check Out™ User Manual MANUAL DE INSTRUÇÕES - Pfaff Industrial Machinery Humidity Control2.indd - Hoch-Rep Tarots & cartes Copyright © All rights reserved.