Home
        QUICK START GUIDE - The Imaging Systems Group Inc.
         Contents
1.    Manual Pen Media Cord    Shipments are checked for completeness  Please confirm receipt of the following items     GUIDE    Power Cord     110 120 volt AC  Warranty Statement   Media Spindles   Sample Media Roll   Print Head Cleaning Pen    User Manual    NOTE     NOTE     NOTE     CAUTION     CAUTION     CAUTION     V24 USERS GUIDE    Confirm the receipt of options specified in your order     Inspect the shipment for any concealed damage that may have occurred during shipment   Report any damage to the carrier of the shipment and the iSys Technical Support team  immediately  While iSys assumes no liability for  in transit  damage  we will assist in  damage claims with carriers     Save the original packaging materials  Any future shipment should be made in the  original packaging  iSys is not responsible for damage caused in any future shipping due  to improper packaging     During shipment  storage or long idle periods  place a length of thermal media between  the print head and platen roller to prevent possible damage to the print head     If plotter is idle for more than 8 hours  release head pressure to prevent platen roller  flat spotting     The electronic components of the V24 plotter can be damaged by electrostatic discharge   ESD   To avoid ESD  maintain contact with a ground source  A grounded wrist strap or  similar should be used     Properly locating the V24 will help to enhance its performance and extend its useful life   The plotter has a wide operating ran
2.    QUICK START GUIDE       Thank you for selecting the V24 plotter  The employees and management at iSys will  make every effort to assist you with operation of your new plotter  It is our sincere desire  that your ownership experience meets your expectations     This guide is provided to help you easily install and operate your new plotter  It contains  important information on the features and functions of the V24     NEED HELP     If you require additional assistance or information  please contact the iSys Technical  Support team at     THE IMAGING SYSTEMS GROUP INC     911 28th Street N E   Calgary  AB T2A 7X1  Canada    Phone   403  204 5212   Toll Free  1 866 415 ISYS  4797   Fax   403  204 1971   E mail  support isys group com    THE INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE    EXCEPT AS PROVIDED BY LOCAL LAW  THE IMAGING SYSTEMS GROUP INC   ISYS  MAKES NO WARRANTY  OF ANY KIND WITH REGARD TO THIS MATERIAL  INCLUDING  BUT NOT LIMITED TO THE IMPLIED  WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE  ISYS SHALL NOT BE  LIABLE FOR ERRORS CONTAINED HEREIN OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN  CONNECTION WITH THE FURNISHING  PERFORMANCE OR USE OF THIS MATERIAL     Trademarks  Centronics is a trademark of Centronics Data Corp  Veratec is a Trademark of Xerox Corp     V24 USERS GUIDE 2    WARNING     CAUTION     NOTE     V24 USERS    EEU elc RR  2  LOCATION  OF THE  24    iniit aaa esed n da itn ti vo eae exe Ee ia  
3.  FIGURE    Ae To  ily no    RU AI A   C 4 E M od       Interface Versatec Interface Shortline Longline  Ribbon Cable Jumper  J9  Header Header    4  Unplug interface ribbon cable   5  Move interface jumper J9 to select  S  shortline  or    L     longline    6  Plug interface ribbon cable into the header to match the interface jumper J9 setting     NOTE  Figure above shows the interface jumper J9  set to shortline     V24 USERS GUIDE Ii    CAUTION  Do not touch the thermal print head  Natural body oils can damage it  Scratches in the  print head will affect image quality  Print head damage caused by users is not covered by  warranty     Your plotter comes with a sample roll of media properly installed  To replace or change  media  refer to the following procedure     FIGURE 13    FIGURE 12       1  Pull up on both lid latches and lift lid up until lid support is locked  figure 12    2  Insert spindles in the core ends of the new media roll     3  Carefully position the new roll in the media housing and seat the spindles in the  spindle blocks  Press down firmly to seat the roll in the blocks  Ensure the roll is  seated squarely in the blocks  figure 13      V24 USERS GUIDE 12    FIGURE 14 TORTHCS DUET        4  The media unwinds from the bottom of the installed roll     5  The media is threaded as shown in Figure 14  Allow an extra few inches of media  through the exit path  past the cutter assembly     6  Once the media is through the exit path  hold the opposite sides of the
4.  ON OFFLINE    2  Press MENU until you reach the  Test PIt  screen    3  Press either UP or DOWN arrow to select  Yes     4  Press MENU to generate the test plot    The checker board plot will begin after about 4 seconds  After the plot is complete the    setting will go back to  No      FUNCTIONS AND SETTINGS    Control panel settings are saved as presets for either USER M1 or USER M2  Presets are  initially set to defaults for all menu functions     Changes to function settings are stored upon pressing MENU or ONLINE  Setting changes  are retained even while the main power is off     V24 USERS GUIDE 18    NOTE     NOTE     USER MODE    Selects between two user defined settings  Default  User 1   To access functions in  either user mode     e select ON OFFLINE  e press MENU button once  User Mode  is displayed  e then  User 1  will be displayed    e press UP Arrow to change setting    SPEED    Adjust the speed of the plot output  The default is ST  Change the speed by selecting the  speed option in the appropriate menu  Move up or down the scale by pressing the up and  down arrows  Speed is in inches per second  ips      Speeds  2  ips   1 1 2  ips   1  ips   1 2  ips     ST single trace mode     If the plot speed is erratic  or if output quality is unacceptable  lower the plot speed   Such problems may arise when data enters the plotter at a slower rate than the plotter is  set for  This is most likely to occur at 2    sec  setting  Lowering the speed enables the  plotter t
5.  if  contrast levels and media settings are acceptable     To change from the default TEST PLOT setting of  No   press the UP arrow button in the   Test PIt  submenu to display  Yes   then press the MENU button to enable the test     Plot creation takes about 4 seconds before plotting  Once plot is complete the display    will go back to  No      EF EEN     Adjust the length of media moved  in inches  if a manual form feed  remote form feed  or  an end of transmission  EOT  is detected  The maximum adjustment is 250 in     The default setting is  5      V24 USERS GUIDE 21    NOTE     NOTE     NOTE     TOF ADJ     Adjust the distance from the perforation to the  I  mark  This setting is used for  perforated roll or fanfold papers only  This adjustment allows the user to select where the  image will start plotting from the perforation     Default  O      Adjustments are in 1 16 of an inch increments     HYST     Used to adjust image quality at higher speeds  This setting looks at the history of each  dot and decides  through an algorithm  the amount of energy needed     Default  Off    Range  Off  1     5  darkest     This setting can make the fill patterns look lighter or darker     EOT CUT    Automatically cuts the media when an EOT command is received from the host  This  setting will advance the media past the cutter then cut the media off     Default  No      Setting  Yes or No    PRE BUFF    Helps hosts with slower data transfer rates to plot using a faster speed without 
6.  media and  tug forward to squarely align and remove wrinkles     7  Clean the print head with the Print Head Cleaning Pen shown in Figure 15     CAUTION  The thermal print head should only be cleaned with the Print Head Cleaning Pen or with  a solution of 99 926 Isopropyl alcohol on a lint free wipe  Water and other solvents can  damage the print head  Print head damage caused by users is not covered by warranty     V24 USERS GUIDE 13    NOTE     NOTE     CAUTION     V24 USERS    FIGURE 16       8  Ensure the lid latches are in the  open  position   9  Lift up on lid and pull up on lid support to release  slowly lower the lid     10  Close and seat the lid latches by pressing down on one corner and pushing the latch  lever down and in  Repeat this process on the opposite side of the lid assembly   figure 16      If the lid latches are not properly seated  the red error light will display on the Control  Panel and  Latches Open  will appear in the LED display     11  Set Control Panel to  ON LINE   see Section 8 for information      Ensure the media type shown in the Control Panel Menu corresponds with the actual  installed media   Refer to Section 8 if changes to settings are required      The imaging characteristics of approved media are matched to the thermal output of the  print head  Operating at incorrect media settings or with unapproved media may damage  the print head  Print head damage caused by such use is not covered by warranty     GUIDE 14    The iSys QuickDraw 
7. 5      4  Slide cable into the exit slot on the bottom back corner and close side panel   figure 6      5  To lock side panel  press the black button     V24 USERS GUIDE 8    INSTALLING THE AC POWER CORD     WARNING  Electric shock warning     FIGURE 7  ne 5          FIGURE 8    S T UV       AC Receptable    1  The AC Powercord is located under the right side panel  It opens in a similar  fashion to the left side panel    2  Push the black button on the right side panel    3  With the black button sticking out  pull on the button to open the side panel  exposing the AC receptacle    4  Plug the supplied AC power cord into the receptacle  figure 7     5  Slide the cord into the slot on the bottom back corner and close the side  panel  figure 8     6  To lock the side panel  press the black button    NOTE  Avoid sharing a power outlet with noise generating equipment     V24 USERS GUIDE    CAUTION  The electronic components of the V24 plotter can be damaged by electrostatic discharge   ESD   To avoid ESD  maintain contact with a ground source  A grounded wrist strap or  similar should be used     WARNING  Electric shock warning     FIGURE 9       Top Lid Top Lid Power Main Control  Screw  1  Screws  2  Board Board    1  Pull on lid latches and lift lid slightly  see figure 12    2  Remove 3 screws on each of the left and right side arms of the lid  see figure 9      3  Lift up on the lid cover to expose the main control board electronics  see figure 10      V24 USERS GUIDE 10   
8. RANTY    The iSys written warranty is included with your shipment  Please take the time to read  the warranty so you fully understand your coverage under its provisions     MAINTENANCE    The V24 requires little routine or preventative maintenance  Recommended maintenance  will enhance performance  extend useful life and can be performed quickly and easily at  the installed location     Use 99 9  isopropyl alcohol to clean the print head     Check that support shock on the lid assembly is functioning correctly     SERVICE CALL    Phone   403  204 5212   Toll Free  1 866 415 ISYS  4797   Fax   403  204 1971   Email  support isys group com    V24 USERS GUIDE 24    
9. Si   OVERVIEW   2 eiectus esee ed NE N E A banesid e outs A Suas cub lu uc Reb USE UNES    4  CABLE CONNECTIONS criminos sncteaeacatbudacatessazds oet ena adu oes aa Gets a A A E EAER  Installing the  Data Cable  e dedos ede eveniet sche araa eta ar ni ea Dar A EEE    Installing the AC  POWER COFG uuo reso ee aote aee ae ture gu xau de Ra x S a eoa Vu pneu  5  VERSATEC INTERFACE SETUP       ue iae a onte rennen rane E Euh e Rea PES e Pea De VE FERE EE PES TOR OE  6   QUICKDRAW MEDIA INSTALL 5 eire rte seta hoe sae voa eau ae rene E ka ead ok Care d eaa cte v edad    Praese qp eV Mb                                   PREMIUM  PAPET T                     Report Pa oigo c S    Gleanings Pers  toco tete ebbe a n rachel nee qe bx aset ape ua DOR QU Nae E ase DOR R UU   UR    8  STARTING THE V24 iine orae eo toco epe perpe is uot senane deb us enero E E  Using the Control Panel sericis e plu nna unu nera d re Deo DU tata dun  VIESTRIUEST  Iso Po E    La Ie de E ESI                                                          M                 9   WARRANTY  MAINTENANCE  amp  SERVICE       nacta rro des nn denota e e nee a aa    A WARNING indicates the potential for personal injury   A CAUTION indicates the potential for damage to the V24     A NOTE indicates special attention is required     GUIDE    WARNING     V24    USERS    The V24 plotter weighs approximately 60 Ibs  Use appropriate care when unpacking   lifting or moving the unit       gt        User Cleaning Sample Power Spindles 
10. button will scroll through the setup menus   When menu to change is selected  use the UP Arrow  FF ADV   button to scroll up  and  the DOWN Arrow  CANCEL CUT  button to scroll down to move through the settings in  each submenu  Once the menu changes are complete press ONLINE button to save your  changes        Setting changes can only be performed in the    OFF LINE    mode     1  Take the plotter OFFLINE by pressing the ON OFFLINE key  The green ONLINE  indicator light will turn off     2  Find the desired menu item by pressing the MENU button until that menu appears in  the LED display  Holding the MENU button will scroll through the menu items faster  and will not display the item setting until button is released     3  Use the UP   DOWN Arrows to change the displayed setting     4  To save the changes  put the plotter back ONLINE by pressing the ON OFFLINE  button  The green ONLINE indicator light will turn on and the display will read     Idle        V24 USERS GUIDE 17    ARROW UP    ARROW DOWN    NOTE     ENU       A     ONES    v    MENU SELECTIONS    Accesses user modes and function menus  Scrolling is from first to last only     Moves the arrow up or down to the item you wish to change  When an item is selected   pressing up down arrow button changes the selection     Holding down the up or down arrow key while a menu item is selected will scroll through  the item options until a menu limit has been reached or the arrow key released     To run a test plot    1  Press
11. e  appropriate menu  Move up or down the scale by pressing the up and down arrows     Default  1184    Range  1184           594     400 dpi resolution   592 stesse  64     200 dpi resolution     The selected bytes per scan on the plotter must match the bytes per scan in the  application software that is running on the attached computer host  If the two settings  don t match the data will look scrambled     V24 USERS GUIDE 20    NOTE     NOTE     NOTE     VERT DPI   To change the vertical resolution  dots per inch  select the  Vert DPI  option in the  appropriate menu  Move up or down the scale by pressing the up and down arrows   Default    200 400       Emulations  200 400 and 203 406 DPI    Image must be rastered to the correct resolution or the image scaling will not be correct     SCALING    Use scaling to compensate plot length measurement for tolerances in media thickness   roller diameter and head pressure  Use scaling to compensate for plot length differences   which are caused by variances in media thickness  Scaling can stretch or shrink a plot up  to one inch     Default setting is  O    Range   40     O      40    Change the scaling setting by pressing the up or down buttons in the  Scaling  submenu   The UP arrow button accesses the positive  stretch  increments of 1 40 inch     TEST PLT    Generates a test plot  Five inches of plot are produced in a checkerboard pattern so you  can see if the plotter is creating a plot image and feeding the paper correctly  and
12. ge and functions well under various conditions  For  best performance  we recommend the following conditions     e Place in a well ventilated  stable environment free from abrupt temperature or  humidity changes         Temperature     10 to 40 deg  Celsius  50 to 104 deg  Full       Relative Humidity 40  and 70   non condensing    e Place on a firm  flat surface    e Avoid sources of direct heat and sunlight     e Allow a minimum of 20 cm  9 in   side clearance for proper airflow     WARNING  The V24 plotter weighs approximately 28 kg   60 Ib    Use appropriate care when lifting  or moving the unit    CAUTION  Do not touch the thermal print head  Natural body oils can damage it  Scratches in the  print head will affect image quality  Print head damage caused by users is not covered by  warranty    CAUTION  Do not block the air vents  Proper airflow helps maintain operating temperature     V24 USERS GUIDE 6    3  Overview    FIGURE 1 me  wwe    wm  eed  WI   Li EIER       Ieft Serial Control ON OFF Right  Latch Number Panel Switch Latch  Plate    FIGURE 2   Ww BER           yellow  Spindle Roller Head Spindle  Block Block    V24 USERS GUIDE E       INSTALLING THE DATA CABLE     FIGURE 3 FIGURE 4       1  Push the black button on the left side panel  figure 3      2  With the black button sticking out  pull on the button to open the side panel  exposing the data bulkhead  figure 4      FIGURE 5 T OC       3  Install data cable into the bulkhead and secure thumb screws  figure 
13. ill appear in the LED display  the plotter is not  operational until this message is replace by  Idle      NOTE  The V24 while plotting  will move the media back and forth when the plotter stops or the  data transfer rate from the host is slow     USING THE CONTROL PANEL    The control panel of the V24 consists of an eight segment LED display  three indicator  lights and four buttons  as illustrated in Figure 17  It allows users to check the plotter  operating status and operating settings  It also provides warning error messages and  feedback to the operator  Plotter settings and operating conditions can be changed  through the control panel menus     EDQGURE  17       DMLDR BSR  DATA    my    ee         TIGE REM py I          The indicator lights show status as follows   1  ON LINE   Green when the plotter is on line and ready   2  ERROR   Red when an error condition stops the plotter     3  DATA   Yellow when plotter is receiving data from the host     V24 USERS GUIDE 16    Button functions are identified as follows        uud Toggles between ONLINE and OFFLINE modes   A FF With plotter OFFLINE  pressing this button once will cause the plotter to formfeed up to  ADV  250 inches  pressing and holding the button will feed media until button is released     CANCEL With plotter ONLINE  and receiving data pressing this button will cancel the current job  CWT plotting  When plotter is OFFLINE  pressing this button will cut the media        When plotter is OFFLINE  pressing this 
14. line of direct image media is matched to the performance  characteristics of our plotters to give you consistent  high quality results at an economical  price  Qualified QuickDraw papers are an essential part of the imaging system that help  to assure peak performance and long  trouble free imager life     PREMIUM PAPER    A premium  heavyweight paper that has the look and feel of bond paper  The high   sensitivity imaging layer and bright white background produce sharp  crisp  fine line  detail and dense solids  It features a protective topcoat that resists water  scratching   scuffing and marring  It is ideally suited for plots requiring frequent handling     REPORT PAPER    This medium weight  high sensitivity paper has a bright white background to produce  high contrast output with crisp fine line detail and dense solid fills  Report paper is an  economical choice for your high volume  general purpose output needs     CLEANING PENS    The convenient cleaning pen assures proper print head maintenance  helps enhance print  quality and prolongs print head life     NOTE  For pricing and delivery on qualified QuickDraw media  please contact your iSys sales  representative or authorized dealer     V24 USERS GUIDE 15    To start the plotter  press the main Power  ON OFF  Switch shown in Figure 1  The plotter  will go through its start up sequence  beginning with the warm up phase  which brings  the unit to its operating temperature     NOTE  During the warming phase   Warming  w
15. o match the input rate of data and produces a smoother  better quality output     CONTRAST    Change the contrast by selecting the   Contrast    option in the appropriate menu  Move  up or down the scale by pressing the up and down arrows     Default    O      Range   4     O      4    If the plot is light  be sure the correct media type is selected  Increase the contrast level  by one and test  repeat if needed     V24 USERS GUIDE 19    NOTE     NOTE     CAUTION     NOTE     PLOT TYPE    Change the plot type by selecting the  Plot Type  option in the appropriate menu  Move  up or down the scale by pressing the up and down arrows     Default  Normal    Types  Normal     Mirror    Setting to mirror the plotter will mirror image the data received     MEDIA    Selects supported media types  The default setting is non top coat  displayed as  Non  T C    Note that if you use other media  you must change the media setting  If unsure of  the media specifications  start at the Non T C  setting and then increase the setting to  Top Coat if necessary     Types  Non T C  and Top Coat    Change the media setting by pressing the up or down arrows in the MEDIA submenu   Select NO T C  P  light paper   TC PAPER  heavy paper      Thermal plotting technology involves high temperatures  Incorrect media settings can    damage the print head or other components  damage the media and void the warranty     BPS    Change the number of bytes per scan  image width  by selecting the  BPS  option in th
16. the stop  and start gaps  This setting uses the onboard memory to buffer the incoming data before  plotting the image     Default  Off    Setting  On or Off    Memory can be expanded up to 32 Meg     V24 USERS GUIDE 22    NOTE     NOTE     NIB SAVE  Helps nib life on vertical boarders that are always turned on     Default  Auto      Settings  Auto  automatically shifts plot left and right   Lock 1  will lock image at that position   Lock 2  Lock 3  Lock 4  Lock 5    Center  will center the image     Auto setting is recommended to help improve nib life  If the print head is missing a nib  the plot can be shifted and locked in place using the Lock  setting     BEEPER    Controls the audible signal for error messages such as media out warning  This sound can  be changed     Default    Off      Settings  Off  turn beeper off on errors   Solid  beeper on continuous until error cleared   Fast P  beeper will pulse at a fast rate   1 Min P  beeper will pulse every minute   3 Sec P  beeper will pulse every 3 seconds   5 Times  beeper will pulse 5 times then turn off     Error condition must be cleared in order to continue plotting     OFFL ERR    When set to    Yes     with an error condition the plotter interface will go offline to the host   Default    Yes        Settings  Yes or No    BUSY OFFL    When set to    Yes     the plotter interface will assert the busy line to the host when the  plotter goes offline     Default    No        Settings  Yes or No    V24 USERS GUIDE 23    WAR
    
Download Pdf Manuals
 
 
    