1. Press the ON button and the unit will beep once The WAIT indicator flashes and the unit begins to warm up displaying a countdown from 14 to zero You must wait until the countdown is complete after which the unit will beep twice and the BLOW indicator will flash Take a deep breath then gently and steadily blow into the breath intake at the top of the unit until the unit beeps 3 times in succession Blow from a distance of about 3cm as if you are trying to cool soup on a spoon As you are blowing Err appears in the display until the sampling process is completed If you do not blow a sufficient sample Err will continue to be displayed Once sampling is complete the unit displays the results in BAC see how to analyse the results below and the reading will remain displayed for 5 seconds after which it will flash for 3 seconds before the unit automatically switches off To retest simply repeat the above process Error Messages Flowcheck if the unit does not sense that a sufficient sample has been provided E rr will appear on the display In this case turn off the unit and try again e Low Battery If the battery power is too low to enable accurate testing the indicator to the left of WAIT will illuminate Do not test replace the batteries prior to further use o Saturation If the unit detects very high levels ie Alcohol in the mouth the unit will beep three times in short successi
2. Warranty The manufacturer warrants this Breathalyser to be free from defects in workmanship or material excluding calibration under normal use for one year from the date of purchase Manufacturer s obligations under this limited warranty are limited to replacing adjusting or repairing the unit if returned along with the proof of purchase This warranty is void if the unit has been tampered with maliciously damaged or physically abused The enforceability of this warranty is limited to the original consumer purchaser and is not transferable to or enforceable by any subsequent owner In the event of a defect malfunction or other failure to conform to this warranty UKBreathalysers will at its sole discretion repair or replace the unit You are responsible for all shipping cost in connection with warranty service This warranty commences on the date of purchase and shall be effective for a period of one year and does not affect your statutory rights Should you need to return your unit or obtain service during the warranty period please call 0870 321 4661 or email to sevice UKBreathalysers com to obtain a RMA number and shipping instructions Remember to return your detector postage paid insured and in suitable packaging DO NOT return your unit without contacting us first Disclaimer UKBreathalysers makes no warranties expressed or implied as to the ability of this device to determine whether a person is intoxicated and expressly discl
3. aim any liability for incidental special or consequential damages of any nature The user undertakes not to make any decisions and or carry out any actions based upon the reading of this device UKBreathalysers assume no responsibility for consequences of subjects who test negative when using this device and later show that they are under the influence of alcohol or their judgment has been impaired by alcohol This device should only be used as a screening device and may only give an indication of the possible presence of alcohol in the blood of the test subject Correlation between breath alcohol content and blood alcohol concentration depends on many variables including temperature and health conditions A safe or low reading on a breath alcohol screener does not mean that the driver s reaction times can respond to any emergency encountered The exact concentration of alcohol in the blood of the test subject cannot be exactly determined by using a breath alcohol screening device THIS BREATHALYSER IS A SCREENING DEVICE ONLY NOT ADMISSIBLE IN THE COURT OF LAW DO NOT DRINK ALCOHOL AND DRIVE ALWAYS USE A DESIGNATED DRIVER AFTER DRINKING ALCOHOL BE SAFE AND DRINK RESPONSIBLY Customer Care If you have questions about UKBreathalysers products or services please contact us via phone e mail or mail Our customer service agents will gladly assist you in any way they can Please contact us via email at the following address mail UKBreathalyser
4. h as diabetes and low caloric intake may cause a false positive test 7 DO NOT DRINK AND DRIVE Always have a designated driver if you are drinking Alcohol How does it work When you drink alcohol it passes through the lining of the stomach into the blood supply As the blood moves around your body it is filtered by the liver which extracts the alcohol over a period of time but also passes through the lungs At the same time as the oxygen in your breath passes through the alveoli into your blood a certain amount of the alcohol that is carried by the blood passes back the other way It is therefore important to measure deep lung air as this is where the blood has been in contact with the air in the lungs A breath from any other part of the lungs will have a lower alcohol concentration and can give a lower reading than should be the case To achieve a consistent reading a consistent sample of deep lung air is therefore required Law Enforcement devices measure an absolute quantity of air usually 1 7ltr each time they are used and employ a chemical fuel cell to measure alcohol concentration This however makes such devices significantly more expensive to manufacture than personal detectors like this that use a timed blow amp semi conductor sensor but with practice the user can achieve a reasonable level of accuracy by ensuring that as far as possible the same blow pressure is used each time a sample is taken How to get the mos
5. on and display 1 2 DO NOT RETEST for at least 20 minutes How to Analyze the Results The UK Drink Drive limit is 0 08 BAC shown on the unitas 0 08 e Do not Drink and Drive The AlcAlert BT5500 is sold for advisory purposes only and cannot be solely relied upon to determine the users level of intoxication e If you consume very little alcohol ie insufficient to read more than 0 02 the device may not be activated and the display will read 000 The unit is designed to operate most efficiently between 0 04 and0 10 readings will be less accurate at very high or very low levels Precautions 1 Always wait at least 20 minutes after your last drink before testing This is because it can take up to 20 minutes for any residual alcohol in the mouth to dissipate and for alcohol to be fully absorbed in the blood 2 Avoid testing in strong winds in a closed room with a heavy smoke or where a lot of alcohol is being consumed 3 Do not blow cigarette smoke food or liquid into the instrument 4 The AlcAlert is designed for use in a temperature range of 10 40 C or 50 104 F Operation of the unit in extreme temperature ranges above or below this range may affect the accuracy of results 5 Avoid testing in the presence of any substances that contain methyl alcohol isopropyl alcohol or acetone These substances may interfere with the results of the test 6 Conditions that increase the amount of ketenes on the breath suc
6. s com UKBreathalysers Limited Fosters Yard Forge Lane Broadbridge Heath West Sussex RH12 3JA United Kingdom Breath Alcohol Detector Be Smart Be Safe Overview The AlcAlert is a breath alcohol screening device designed to test for the presence of alcohol in the blood This device is intended to be used in all populations with lung capacity capable of producing at least 1 5 litres of exhaled air The AlcAlert is powered by 2 x AAA Batteries that generally lasts be tween 200 300 tests Preparing For Use Install the included AAA Batteries Apply a small amount of pressure on the indentation of the battery compartment cover and then push down and away from the unit simultaneously in order to release the cover Install the batteries and replace the battery compartment cover See the following diagram Observe the correct polarity on the inside of the case as incorrect insertion may damage the unit Always leave at least 20 minutes between drinking and testing If you do not wait 20 minutes before testing the reading will measure the alcohol in your mouth which is many times that related to your blood alcohol level The detector contains a highly sensitive semi conductor sensor and not waiting the required time could damage saturate this sensor and can cause all future readings to be inaccurate Please also ensure you do not blow any smoke or liquid into the unit or the same damage can result and de calibrate the detector
7. t from your Breathalyser When first using the device 20 minutes after your last drink try testing yourself three times approximately two minutes apart in order to bracket the readings An average reading can then be assessed as can the consistency of the blow level required Note the reading and then test again 30 minutes later and so on until the unit reads zero Try the unit on others you are likely to find considerable variance in the way in which individuals metabolise alcohol depending upon body mass when they last ate time of day etc After a while you will start to develop a reasonable idea of the way in which you personally react to Alcohol and you can then modify your drinking appropriately to ensure that you always leave a more than adequate period after drinking and before driving UKBreathalysers would always recommend you do not drive with ANY alcohol in your system and that you leave a substantial safety margin between the time you believe you have reached a zero level and the point where you may consider driving Never rely solely upon the readings of this detector in determining your fitness to drive Cleaning Although it may seem logical to clean the alcohol detector with alcohol or other cleaning agents in reality this is very harmful to the semiconductor sensor in detector All semiconductor sensors are intolerant to high doses saturation of alcohol and other cleaning or anti bacterial agents Simply wipe the
8. unit over with a damp not wet cloth and dry thoroughly