Home

TestStand Release Notes

image

Contents

1. Distributing TestStand 0 cece eseeteeeeeeeeees 10 GOSSALY secede Sa ETETEN EERIE PEENE ETE EE E EEEE EOT 11 Additional Changes esseseeeseseeeessesrerssrsrrersseesssrssrrrsreersreseerrereeesrs 12 LabVIEW natinst com National Instruments and TestStand are trademarks of National Instruments Corporation Product and company names mentioned herein are trademarks or trade names of their respective companies 322519B 01 Copyright 1999 2000 National Instruments Corp All rights reserved February 2000 TestStand Installation The TestStand setup program installs TestStand on your computer in approximately 10 minutes Minimum System Requirements To run TestStand for Windows 2000 NT 98 95 you must have the following Installing TestStand Windows 2000 NT 4 0 or later or Windows 98 95 For Windows NT National Instruments recommends Service Pack 3 or later At least a 133 MHz Pentium class or higher microprocessor SVGA resolution or higher video adapter with a minimum 800 x 600 video resolution Minimum of 64 MB of memory 70 MB free hard disk space Microsoft compatible mouse 3 Note National Instruments recommends that you close other applications before you install TestStand TestStand Release Notes Follow these instructions to install TestStand 1 5 Make sure that your computer and monitor are powered on and that you have installed Windows 2000 NT 4 0 or later or Windows 9
2. appropriate users so that they can access the local client machine For Windows 95 or Windows 98 you must complete the following steps to configure the security permissions for the local client 1 You must configure your Windows network options in the system control panel to use User level access control to use distributed COM 2 Run dcomenfg from the command line which displays the Distributed COM Configuration Properties application window 3 On the Default Properties tab make sure that the Enable Distributed COM on this Computer option is checked 4 On the Default Security tab make sure that the Enable Remote Connection option is checked 8 www natinst com 5 On the Default Security tab of the Distributed COM Configuration Properties application window edit the default access permissions You must give access permission to the appropriate users so that they can access the local client machine Configuring the ActiveX Automation Adapter The following options were added to the ActiveX Adapter Configuration dialog box e Run Time ActiveX Reference Type Checking During execution the Automation Adapter can attempt to verify that the ActiveX Reference you specified in an Automation Call is a reference to the correct type of object A run time error is generated when this option is enabled and you pass an ActiveX Reference to an incorrect type of object Disable this option to improve execution speed e Unload Unused Ac
3. sNew txt file for a complete list of changes in TestStand 1 0 2 which address changes in the Windows 2000 operating system Changes to the TestStand 1 0 Database Components This section describes the changes to the database components between TestStand 1 0 and TestStand 1 0 1 Custom Data Type Changes The following changes have been made to the DatabaseOptions data type The data type contains a new subproperty ConnectionString ConnectionString defines the data link that the process model uses The data type no longer contains the following properties DataSourceName Database UserID Password DatabaseSpecificAttributes IsolationLevel AccessMode ConnectionTimeout CommandTimeout CursorLocation and TransactionAttributes The following changes have been made to the DatabaseColumnValueList data type National Instruments Corporation The data type has been renamed to DatabaseColumnValue The data type has changed from a custom data type to a standard data type The data type contains two new properties WriteNull and Status 3 TestStand Release Notes B Note The sequence editor automatically converts sequence files that use the above types You must manually edit any expression that references the renamed or deleted properties Step Type Changes The dynamic link library has been renamed from Database_32 d11 to TSDBComponents dll The following changes have been made to the database component step type
4. start of a new execution National Instruments Corporation 7 TestStand Release Notes Chapter 10 Built In Step Types Update the introductory text as follows This chapter describes the predefined step types that TestStand includes except for the database step types Refer to the TestStand User Manual Addendum for more information on the built in database step types You can find the addendum at TestStand Doc TestStandDatabaseComponents pdf Chapter 12 Module Adapters TestStand Release Notes This section describes the changes to the module adapters Sequence Adapter Add the following paragraphs to the Sequence Adapter section You cannot pass an ActiveX Reference as a parameter to a remote sequence unless you configure the local client machine to give access permission to the user that is logged into the remote server machine For Windows 2000 NT you must complete the following steps to configure the security permissions for the local client 1 Login using a userid that has administrator privileges 2 Run dcomcnfg from the command line which displays the Distributed COM Configuration Properties application window 3 On the Default Properties tab make sure that the Enable Distributed COM on this computer option is checked 4 On the Default Security tab of the Distributed COM Configuration Properties application window edit the default access permissions You must give access permission to the
5. 8 95 Insert your TestStand Installation CD into your CD ROM drive Choose Run from the Start menu Type x tssetup exe in the input box where x is your CD ROM drive Click on OK Follow the instructions that appear in the dialog boxes National Instruments recommends that you install the complete TestStand program to take full advantage of all the TestStand capabilities If you choose to install with options select the options you want and follow the directions on the screen If necessary you can run the setup program again later and install additional files Refer to the Test Stand Doc Readme txt file for any additional issues that are too recent to be included in the printed TestStand documentation 2 www natinst com What Is New and Different in TestStand 1 0 1 and 1 0 2 New Features TestStand 1 0 1 contains the following new features Multibyte character string support for the localized versions of Windows for example Japanese Database Components which were included in beta form on the TestStand 1 0 CD are now part of the TestStand installation See the Changes to the TestStand 1 0 Database Components section below for more information and a list of database component changes between TestStand 1 0 and 1 0 1 Refer to the Test Stand Doc What sNew txt file for a complete list of changes and enhancements in TestStand 1 0 1 TestStand 1 0 2 contains the following new features Refer to the Test Stand Doc What
6. RELEASE NOTES Yd TESTSTAND RELEASE NOTES Version 1 0 2 Contents lt 7 NATIONAL INSTRUMENTS These release notes contain system requirements installation instructions new features and updated information to help you begin using TestStand 1 0 2 TestS tand Installation ninsisti ii i i erari ede te 2 Minimum System Requirements 0 eee ceesee ese ceeeeeceeeeeeeees 2 Installing TestStand oo eee ceeeeeceeeeeeeeseeseecaeesaecaecaeeaecseeseens 2 What Is New and Different in TestStand 1 0 1 and 1 0 2 we 3 New Features menneen A nigga niece 3 Changes to the TestStand 1 0 Database Components 3 Additional Support Information 0 cee ee eee eeeeeeeeeeeeseeseecaeenaeeeesaees 5 Changes to the Getting Started with TestStand Manual 5 Chapter 10 Using ActiveX in Code Modules 0 ee eee 3 Changes to the TestStand User Manual eseeeseeeeeeeeesrrerrererrrreeeerseres 6 Run Mod seene a in eee eee ee eee a 6 Chapter 3 Configuring and Customizing TestStand o oo 6 Chapter 4 Sequence Editor Menu Baro ee eee eeeeeeeeeneeeeee 6 Chapter 8 Sequence Context and Expressions ce eeeeeeeeeeee 7 Chapter 10 Built In Step Types 0 eee eeeeeeeeeeeeeeeeeaes 8 Chapter 12 Module Adapters 20 0 0 ccc ee eeeeseseececseeesecnseeeeeeees 8 Chapter 13 Process Models 0 ce cecceeceeeeseeeseeseecsecseeesecnseeseeneens 10 Chapter 15 Run Time Operator Interfaces eee 10 Chapter 16
7. TestStand Create Test Data Cluster vi Foran Action Step type TestStand uses only the Report Text terminal Do not pass the error status to the Pass Fail flag for any step type e Replace step 22h on page 10 11 with the following paragraph Add a Waveform Graph indicator and a Dialog button to the VI front panel as shown in Figure10 9 3 Note Figures 10 9 and 10 10 should display Waveform Graphs rather than XY Graphs National Instruments Corporation 5 TestStand Release Notes e Add the following paragraph to step 22i on page 10 12 Do not wire any inputs to the TestStand Create Test Data Cluster vi For an Action step type TestStand uses only the Report Text Terminal Do not pass the error status to the Pass Fail flag for any step type Changes to the TestStand User Manual Run Mode This section contains information on several changes and additions to the TestStand User Manual Throughout the manual it is stated that run mode changes made to a step in an execution window apply only to that execution In fact these changes apply to all current and new executions until you modify the run mode again in an execution window or a sequence file or until you reload the sequence file Chapter 3 Configuring and Customizing TestStand Add the following paragraph to the end of the Modifying the Process Model section Refer to the TestStand User Manual Addendum for more information on customizing the information that Tes
8. The Distributing the TestStand LabVIEW Run Time Server section on page 16 14 states the following If you want to manually register the ActiveX server in a LabVIEW run time application you can launch the executable with the Register keyword on the command line For LabVIEW 5 1 this server registration command line argument has changed to RegServer Glossary Add the following glossary terms e ADO ActiveX Data Objects e data link Connection information for opening a data source such as a database A data link typically specifies the server on which the data resides the database or file that contains the data the user ID and permissions to use when connecting to the data source e DBMS Database Management Systems e _ODBC Open Database Connectivity e OLE DB Object linking and Embedding Database Additional Changes Any instance of Login Name within a dialog box has been renamed and will now be referred to as User Name This affects the Edit User New User and Login dialog boxes Refer to the TestStand User Manual Addendum for more information on the database components included in TestStand 1 0 1 You can find the addendum at TestStand Doc TestStandDatabaseComponents pdf National Instruments Corporation 11 TestStand Release Notes
9. n TestStand Release Notes 4 www natinst com Converting Sequences that Use Beta Database Components TestStand 1 0 1 and TestStand 1 0 2 automatically convert any sequence that uses a beta database component step type or custom data type If an expression within a sequence references an obsolete property from a TestStand 1 0 database component you must manually correct the expression Additional Support Information For additional information on TestStand refer to the National Instruments Web site at www natinst com support teststand The Web site contains many electronic support services such as a KnowledgeBase database example programs and software libraries These resources can help you in your development National Instruments also offers an e mail based TestStand technical discussion forum You can join the forum by sending an e mail to listserv listserv tamu edu with the following text in the body of the note SUBSCRIBE TESTEXEC lt first name gt lt last name gt You will receive an e mail response with further instructions on sending messages to the forum and unsubscribing from the forum Changes to the Getting Started with TestStand Manual Chapter 10 Using ActiveX in Code Modules This section describes the changes made to the code module exercises Using ActiveX in LabVIEW Test Virtual Instruments e Add the following paragraph to step 18b on page 10 9 Do not wire any inputs to the
10. nfigure data source names in the ODBC Administrator When you install TestStand on a target system you must ensure that these database components are configured properly on the target system Customizing and Distributing a LabVIEW Run Time Server This section contains a description for LabVIEW 5 0 and earlier The Application Builder has changed for LabVIEW 5 1 For LabVIEW 5 1 or later replace steps 2 6 on page 16 13 with the following Select Project Build Application Press Load and select TestStand Components User RuntimeServers LabVIEW Test StandLVRTS bl1d Press Build to build an executable For your information the Test StandLVRTS b1d file contains the following settings e Under the Target tab the Application name is TestStandLVRTS exe e Under the Source Files tab Test Stand Runtime Server viin Server 11b is enabled as the top level VI e Under the VI Settings tab no changes were made e Under the App Settings tab the Enable ActiveX Server is checked and the Server Name is Test StandLVRTS e Under the Installer tab you have the option to make an installer If you use the installer to distribute your ActiveX Server you need to manually copy the t 1b file and place it in the same directory as TestStandLVRTS exe The LabVIEW 5 1 installer does not copy this particular file This will be corrected in a future version of LabVIEW 10 www natinst com Distributing the TestStand LabVIEW Run Time Server
11. s OpenDatabase This step type contains a new subproperty ConnectionString ConnectionString defines the data link that the step uses The following step properties no longer exist DataSourceName Database UserID Password DatabaseSpecificAttributes IsolationLevel AccessMode ConnectionTimeout CommandTimeout CursorLocation and TransactionAttributes SQLAction The descriptive name for the step type has been renamed from SQLAction to DataOperation The ColumnValuesExpression property has been renamed ColumnListSource The ColumnValues property has been renamed ColumnList The property CacheColumnNumbers no longer exists The property SOLStatement has been added 3 Note The sequence editor automatically converts sequence files that use the above types You must manually edit any expression that references the renamed or deleted properties Database Schema Changes The following fields in the STEP_RESULT default table schema have changed INTERACTIVE_EXECUTION_NUMBER has been renamed INTERACTIVE_EXENUM OMPARISON_OPERATOR has been renamed COMP_OPERATOR G SERVER has been removed R EPORT_TEXT has been added 3 Note You must manually convert the default table schema from TestStand 1 0 to TestStand 1 0 1 Oracle does not allow you to rename fields so you must create a new column and copy any existing data from the old column to the new colum
12. tStand logs to a database You can find the addendum at TestStand Doc TestStandDatabaseComponents pdf Chapter 4 Sequence Editor Menu Bar TestStand Release Notes This section describes the changes to the sequence editor menu bar Database Options Add the following section below and at the same level as the Report Options section The Database Options command displays a dialog box in which you can customize the logging of step results and UUT results to a database The command calls an entry point in the default TestStand process model file The options you set apply to all sequences you run on the station Refer to the TestStand User Manual Addendum for more information on logging data to a database You can find the addendum at TestStand Doc TestStandDatabaseComponents pdf 6 www natinst com Preferences The following option was added to the Preferences Tab on the Station Options dialog box Prompt to Change System SetForeground Window Behavior On Windows 2000 98 you can configure the operating system so that a test module you run in a process separate from TestStand cannot bring a window to the front when TestStand is active When your test attempts to bring a window to the front the window taskbar button blinks to notify the user that another application is attempting to bring a window to the front During engine initialization TestStand can detect this system configuration and prompt you for permission to change
13. the system settings to allow your tests to bring their panels to the front Notice that this is a system setting Changes to this setting affect the behavior of any application attempting to bring its window to the front when another application window is active Disable this option if you do not want TestStand to detect this system configuration When you disable this option TestStand does not prompt you and TestStand does not change your system settings National Instruments recommends that you enable this checkbox and allow TestStand to change your system settings when you execute test modules in external processes This system configuration setting is a DWORD value stored in the registry The value is HKEY_CURRENT_USER Control Panel Desktop ForegroundLockTimeout This value is the amount of time in milliseconds that a foreground application must be idle not receiving user input before the operating system allows a background application to bring its window to the front The typical value for this setting is 0x7D0 2 000 ms TestStand sets the value to zero Chapter 8 Sequence Context and Expressions Add the following property to Table 8 6 The InitialSelection Subproperty in the Sequence Context SelectedExecution Specifies the execution object for the active execution window file when the execution started This property exists only in the root sequence context and only when an execution window is active at the
14. tiveX Servers After Execution When this option is enabled the Automation Adapter requests that the operating system unload in process DLL servers after every execution The operating system unloads only servers that are no longer being used Disable this option to improve execution speed Chapter 13 Process Models Add the following entry to Table 13 3 Default Process Model Files Database seq Subsequences that log UUT results to a database Chapter 15 Run Time Operator Interfaces In the LabVIEW Run Time Operator Interface section steps 9 and 10 on page 15 5 are incorrect Do not make a new testexec 11b for these steps Refer to the updated LabVIEW 5 1 instructions in the following locations to create run time operator interfaces and a LabVIEW run time server using LabVIEW 5 1 OperatorInterfaces NI Lv readme doc Examples OperatorInterfaces Simple LV readme txt Components NI RuntimeServers LabVIEW readme txt National Instruments Corporation 9 TestStand Release Notes Chapter 16 Distributing TestStand TestStand Release Notes This section describes the changes to the distribution of TestStand Distributing OLE DB Providers and ODBC Database Drivers Add the following section below and at the same level as the Using a Custom TestStand Engine Installation section The TestStand engine installer does not have the capability to distribute OLE DB providers or ODBC database drivers or to co

Download Pdf Manuals

image