1. g Carry out a skin evaluation after treatment Course of treatment One course of treatments includes 5 treatments at an interval of every 10 days 1l5days Curative effect After one treatment the heated subcutaneous fiber shrinks instantly therefore skin becomes smooth compact and elastic After one course of treatment Skin be comes compact and flabby skin is improved 4 2 3 Back of hand Operation procedure About 60 90 minutes for topical area a Carry out a skin evaluation before treatment b Clean skin c Smear gel on skin and apply treatment with hand piece d Clean skin e Moisturize skin with cosmetics f Carry out a skin evaluation after treatment Course of treatment One course of treatments includes 5 treatments at an interval of every 10 days 1l5days Curative effect After one treatment the wrinkles on the hand are improved and skin becomes tender After one course of treatment Skin becomes tender and smooth and the wrinkles on hand are improved Cautions a And the principle for treatment is that the patient should feel hot but not very or burned b Replacing treatment head When you want to replace the treatment head during treatment XTL 11 5 Settings interface Click the system settings enter the system settings interface picture 8 T tmp T DEHEo noono0OO The accessories of this machine include e Protective glasses e Eyepatch e Power cable e Funnel e Pipe e User s
2. 8 inch touch screen Power supply 220V 50Hz 110v 60Hz Main machine size 60 42 38cm3 Net weight 21 KG 22kg with additional RF head Gross weight 35 kg 36 kg with additional RF head Package size 68 54 54 1 2 Parts and control Machine box Controlling panel The treatment head E light Bi polar The microprocessor inside inside the machine can keep on supervising and controling the working of the system Control panel E light treatment head There are two sockets on the back of the machine as follows A Caution A E light 1M Bi polar RF When you plug the wrong hand piece the following hint will appear Installation Error 1 2 1 Machine box Machine box is the heart of E LIGHT system It includes the following parts Power supply module Supply power to other mo dule and cut off power when the system has malfunction The control module Control and assort with the whole module of system The display controller Display various information of the system and accept the instruction of users High voltage power supply Supply electricity to capacitor Capacitor Store energy that intense pulse light needs The Simmer power light the lamp and keep it in preignition state Cooling system Cool the treatment head AN Caution Please don t open the back cover board without the engineers guide and maintain each internal module of this machine 1 2 2 Control panel The operator controls the
3. gel on the face get drier please add some water and go on with the treatment 4 2 1 Face Including cheek eye forehead lip neck and acne scars Operation procedure About 60 minutes for whole face 30 45 minutes for neck a Carry out a skin evaluation before treatment b Clean skin c Tone skin d Massage with cosmetics e Clean skin f Smear gel on skin and apply treatment with hand piece g Apply anti aging distillate h Wear face mask for 15 20minutes i Clean skin k Moisturize skin with cosmetics k Carry out a skin evaluation after treatment Course of treatment One course of treatments includes 5 treatments at an interval of every 10 days 15days Curative effect After one treatment the heated subcutaneous fiber shrinks instantly therefore fine wrinkles are improved and skin becomes tender smooth and compact After one course of treatment The collagen protein is regenerated for a long term skin becomes tender and smooth wrinkles are reduced and skin is tightened and compact Note Apply face mask twice a week at home 4 2 1 Body Including shoulder back waist abdomen leg arm and buttocks Operation procedure About 60 90minutes for topical area a Carry out a skin evaluation before treatment b Clean skin c Massage with body slimming distillate d Smear body slimming distillate on ski n and apply treatment with hand piece e Clean skin f Moisturize skin with cosmetics
4. it has already been marked the local rated voltage according to the customers request It corres ponds to the electricity requirement as follows AC220V 10 16A 50Hz or AC110V 10 20A 60Hz Input electric current can t have momentary change electric voltage or electric current peak and sinking We suggest that the E LIGHT system use separate wire and air switches The main safety device in the machine is the 10 A chopper 2 3 Installation Take out the machine from the box and place it carefully in the appointed room where the indoor temperature is at 10 C 28C and the humidity is not over 80 Keep the operation room and treatment bed clean all the time Infuse distilled water from the water infusion hole until the water line reaches the 2 3 place of the water level observation Install the treatment head Requirement keep the connection part dry and install it correctly Link the power supply Switch on After completing the above installation insert the key and turn it left the machine is switched on at once at this time water begin to circulate and the cooling system starts automatically Check Observe instrument to make sure that no water leaks If it is leaks shut off the power supply and contact the dealer Add water When the water in the machine begins circulating the water level inside will drop so y ou should add some water to the 2 3 place of water level observation
5. should be in the direction of the arrow of the filter The instructions for installing the big spot filters for the E light treatment head are as follows Attain Maybe it is caused by incomplete connection between the filter and the head if the cooling effect of the filter is not good You can improve it as the instructions of the following pictures The big spot filters should be kept clean to avoid burn You can do the cleaning with alcohol as following instructions This chapter describes the operation steps of the E LIGHT system i Warning There is high voltage in the E LIGHT please make sure all front panels are well covered When the E LIGHT starts please place the treatment head in its holder All personnel need to wear protection glasses or eye patch in the treatment room Even wearing the protective glasses do not look straight at the intense light emitted from the treatment head The treatment head shall not point to any other place besides the target Evnrnaccrira anaraw tnaward tha araa tn ho troaatad maw hirt cbin 3 1 Software operation explanation After Installing the e light or RF hand piece please switch on the machine Choose the language Espa ol English As shown in Picture Into the interface select the appropriate language English Spanish Click the appropriate language and Click Enter The software system will identify the hand pieces RF or E light
6. the lower energy density emitting a test light spot to evaluate the patient s reaction 2 After entering the working interface the capacitance starts refresh Press the button on the head at this time then can carry on the treatment After a shot the number of counter will add one the system starts recharged automatically repeating the above mentioned process 3 To check the cleanness of the filter If it looks unclear please wipe with wet soft cloth 4 Spread gel of 2 3mm on the treatment area The intense pulse light will be conducted into the skin through gel which should be spread before treating 5 Hold the treatment head vertically on the skin press lightly the treatment head should get in touch with gel well 6 Press the button to shoot an intense pulse light the systemwill refresh again automatically it takes about 2 seconds 7 Wipe off the gel check the treated skin to evaluate patient s instant reaction Treat the next skin area and allow Imm between the next area and the treated one 9 Record the treatment parameters to provide information and reference for next treatment Caution After the treatment please put back head in the holder let the system return the FMeny 4 1 Application Facial skin tightening Fine wrinkle removal The mandible and the neck skin tightening Improve the conditions of sagging skin Forehead wrinkle removal Breast lifting Renew back contours Renew belly contours S
7. 2 4 Replace the water Replace the water inside every 2 to 3 weeks and please do it according to the following steps Strictly Drain water in the machine Screw off drain plug lift up the front of the device to drain water completely Infuse water again following the above mentioned steps Link the power supply according to the above mentioned steps Attention 1 In order to guarantee the safety of operation please increase the distilled water up to 2 3 place of the water level observation 2 Please use the distilled water not pure waters only 3 if the machine has been in the room with its inside temperature below 0 C for a long time there may be frost inside the machine and t he machine may be damaged Method place the machine in a room with a temperature at 20C for 24 hours then you can carry on operation ra Caution 1 In order to guarantee the machine operated safely please increase the distilled water to the cooling system in time It is not our responsibility if the treat ment head is damaged because of the shortage of cooling water 2 While adding the distilled water for the first time please carry on according to the above steps then start the system 3 Use the distilled water or purified water only The water temperature can not be lower 2 5 Installing the filter Please install the filter as following pictures pay attention to the direction of the filter the direction of the arrow on the head
8. E light Treatment System User s Manual 1 1 Specifications 1 2 Parts and control 1 2 1 Machine box 1 2 2 Control panel 1 2 3 The E LIGHT treatment head 1 3 System program 1 4 The environment requirements 2 2 1 Space requirements 2 2 2 Electrical requirements 2 3 Installation 2 4 Replace the water Chapter 3 Operation 3 1 Software operation explanation 3 2 Treatment 4 2 Taboos 10 13 13 19 21 21 21 4 4 1 Preparation 4 4 2 Operation Examples 4 5 RF Parameters Chapter 5 Accessory 5 2 The Gel Pyare taal e tne ad EO a ET alates Gad ides Cadet 21 24 24 24 26 30 30 30 TaN Warning Before operating and maintaining the E LIGHT treatment Instrument please read user s This chapter introduces main parts of E LIGHT the control system and parameters 1 1 Specifications Light source Intense pulsed light Spectrum range 420 1200nm 510 1200nm 560 1200nm 585 1200nm 610 1200nm 640 1200nm 690 1200nm IPL energy density 10 50J cm2 Pulse method Intense pulsed technology can adjust Pulse sequence 1 5pulse Pulse Intermission 1 20ms Pulse width 1 20ms Repeat frequency 0 3 1Hz E light Spot size 15X 50mm2 Optional bi polar treatment head 20mm 30mm 35mm RF energy level 1 30J cm2 Frequency OMHz Cooling system Water cooling forced air cooling and semiconductor cooling Cooling temperature 4 4 C Operation interface
9. automatically and one of the following interfaces will appear When the system is equipped with Two socket the two options E light and RF will appear on the main treatment interface Choose E light Click Enter into the treatment mode selection interface Select Therapy Program Skin Rejuvenation Photol i polysis Choose the Function Click Enter Click the appropriate treatment modalities as shown in Picture into the treatment of interface setting the treatment according to customer s specific circumstances Click Professional enter the corresponding treatment operation interface Replace Lamp AN The key for RF RF Time E eanna RF Energy J cm Nd Pulse Tai K4 IPL Energy al J cm time The key for RF Energy adjustment Pulse Interval The Total Count Jz i Fst The key for IPL tota Energy Th k e ey indicates that the capacitor is HID did not shine Notice When use the E light function please first adjust the IPL energy into 10 J cm2 then cooling the water temperature is water level beyond the setted value is low adjust the RF energy to a proper energy level When the patients feel the bearable hot feeling then adjust the IPL energy to the proper energy level you need For other adjustment please reference the IPL parameters 3 2 Treatment 1 We suggest starting the treatment by using
10. cess of the system in order to prevent unexpected trouble Examine the system energy Choose the treatment ranges 1 4 The environment requirements Working temperature scope l10C 30C Relative humidity scope lt 80 Atmospheric pressure barometric 86kpa 106kpa The store environment temperature 0 C 55C Power supply AC220V 22V AC110V 11V 50Hz 60Hz 1 Hz The E LIGHT treatment system can be used in the hospitals and the beauty salon Before installation the preparation is very simple The installation process includes Dismantle the packing and place the E LIGHT system in the pre chosen location Check the whole system and its parts Infuse distilled water into the water tank Connect the power supply Test all functions of the E LIGHT Install and use 2 1 Detailed list of the equipments The following is the detailed list of equipments of this machine Host The hand pieces Protective glasses Gel The plastics cover of filters Funnel Pipe Power wire Manual 2 2 Installation requirements Before tearing down the packing of the E LIGHT system please check whether the position conform to the requirement of this chapter 2 2 1 Space requirements The E LIGHT system should be kept away from the hot place with a draught and should be kept a distance over 60 cm from other objects It s good for avoiding radiation and collision 2 2 2 Electrical requirements Before the E LIGHT leaves the factory
11. ee at eS a Renew buttocks and legs contours Hand care Improving the channel between the lip and the nose 12 Weight losing of the arms and legs 4 2 Taboos To avoid using the machine on the abdomen of the pregnant women or women in menses To avoid using the machine on the special parts such as the ear the nose the eye ball and the larynx etc To avoid using the machine on around the parts under which metal plastic or silicon were buried To avoid using the machine on around the medical and electronic instrument such as the hearing aid heart starter mechanical heart etc To avoid using the machine on the children under the age of 12 To avoid using the machine on the epileptic and those in bad health To avoid using the machine on the wound around the treatment area and the areas with metals inside of the body for those with the loop shaped metallic intrauterine device it is not allowed either To avoid using the machine on those with over expect on the result To avoid using the machine on people who has high blood pressure or diabetes or serious skin diseases or heart diseases or who is sensitive to electric current or who is receiving hormone treatment 4 3 The RF treatment head The RF treatment head contains electronic components emitting RF It connects the system through a set of cable The instructions for installing the big spot filters for the RF treatment head are as follows B
12. ipolar treatment heads in two sizes as following a Smaller part such as the eye the neck etc the abdomen back chest waist abdomen buttocks two thigh etc Pressing the key on the RF treatment head can emit RF which is delivered to the area to be treated through the head Inside the RF treatment head there is the thermoelectricity type semi conductor refrigeration a 30 The medium sized parts such as the face upper arm o system to be used to cool down the treatment head So the temperature of the skin surface can be lowered down so as to reduce the patient s discomfort 4 4 Operation procedure 4 1 Preparation 1 Turn on the machine by the Key Switch 2 Press the RF and enter the interfaces picture Select Function Treatment modes Cont inuous Total Count Energy m3 J cm The Total counter Ce F The a lt Energy The key for cooling A By adjusting the cooling system you can make the treatment head to reach the right temperature B Select the treatment modes Continuous or Pulse C Set the RF energy Level according to the parameters table Operation technique Let the treatment head touch the target area and move or slide from the inner to the outer and round and round and from the lower place to the higher do it in this way again and again when you do the treatment on the upper lid please move a bit more quickly when the
13. manual
14. system through the control panel which includes the following parts Key switch To be used to turn on and off the power supply Emergency Switch pressing this switch will shut off the whole power supply of system immediately It has priority over the system performance compared with the key switch Follow the arrowhead direction turn the emergency switch clockwise and loosen it at once otherwise the machine will be kept off The LCD The operator exchanges information by the LCD The system state operation interface hints and instructions are all on the LCD 1 2 3 The E LIGHT treatment head The E LIGHT treatment head contains electronics components emitting intense pulse It connects the system through a set of cable there is a filter with filmed at the end of treatment head The E LIGHT treatment head can emit intense light by pressing the red key on it which is delivered to the area to be treated through the 8X40 mm filter in the head It is very important to keep the filter clean Inside the E LIGHT treatment head there is the thermoelectricity type semi conductor refrigeration system used to cool down the filter Then the temperature of the skin surface can be lowered down so as to reduce the patient s discomfort 1 3 System program The program of the E LIGHT mainly has four functions Allow the doctor to choose the best characteristic parameters for the patients according to the concrete diagnosis Control the working pro
Download Pdf Manuals
Related Search
Related Contents
Husqvarna 327HDA65x series Lawn Mower User Manual White Star Sky II DMX V5 JVC AV-27D503 User's Manual CCAP - Maintenance réseau & armoires Customer activation system PSG Commercial Workstation Datasheet updated NJTA TMD5 Specs 17 - Division 26 Electric File PBCC: PicoBlaze C Compiler User Manual 簡易版(日本語) Copyright © All rights reserved.