1. Note with factory settings enabled See digital I O states chapter 6 3 Temperature sensor querying Querying of the temperature sensor is only possible via SMS and querying is not possible via voice commands DTMF tones ure reading is available with 1 C resolution If no sensor is connected to the TEMP terminals querying of the temperature will produce a reply SMS with the message TEMP NOT VALID The temperat Querying of the temperature sensor during an active alarm condition produces a reply SMS with the message TEMP xx C ALARM SMS text SMS reply Action Example of reply TEMP TEMP xx C reading temp sensor Ni1000 TEMP 22 C TEMP TEMP xx C ALARM reading temp sensor Ni1000 with alarm threshold exceeded _ TEMP 02 C ALARM TEMP TEMP NOT VALID sensor Ni 1000 not connected or interrupted Building Technologies ATE TEL50 GSM 7 Extended configuration Using the basic configuration already present the user can customize device parametrization by changing some of the system parameters via SMS Carefully note any changes made and keep them with these instructions in order to ensure that the device is correctly controlled even after a long period of time or by other qualified users 7 1 Creation of a qualified user list All the telephone numbers of users both fixed and mobile up to a maximum of 20 that have access to the different features of the device are entered in
2. USER command examples SMS command SMS reply Action USER USER01 3351234567 1 USER01 3351234567 1 User USERO1 set as Administrator USER USER02 3471234567 2 USER02 3471234567 2 User USER02 set as User USER USER03 3291234567 3 USER03 3291234567 3 User USERO3 set as Notify USER USER20 3201234567 USER20 3201234567 User 20 set as Notify USER USERO1 USER01 3351234567 1 queries USER01 position USER USER05 USER05 deleted queries USERO5 position no number present USER USERO1 USERO1 deleted cancels USER01 position USER 3351234567 USERxx deleted cancels the User number 3351234567 from position xx The USER numbers entered without extension assume the Notify User extension 3 default value There is no limit to the In this section there is a SECURITY parameters that enables control of the incoming call numbers When this parameter is enabled SECURITY 1 only the users in the USER list can interact with the device number of users for each profile according to their profile adminis not receive a reply The SMS number must be exactly the same as the configured SMS or it will not be recognized When the list is empty in case of activation SECURITY 1 the ni list wi rator user notify A voice cal administrator even in case it has been inserted as user or notify or an SMS message from a number that is not on the USER umber used to send this SMS will
3. automatically be inserted as USER SMS command SMS reply Action USER SECURITY 0 SECURITY 0 Incoming calls filter disabled USER SECURITY 1 SECURITY 1 Incoming calls filter enabled USER SECURITY SECURITY 0 or SECURITY 1 queries status of SECURITY variable Building Technologies 19 TEL50 GSM 7 2 Modification of Input Output identification string In this section the User can modify the identification string ALIAS for the device inputs outputs New identification strings will support the factory s ones that remain active Queries or commands can be sent using either factory s strings or ALIAS set by he user If no changes are made the factory settings are maintained The defined alias will have a maximum length of 10 alphanumeric characters 0 9 A Z Observe the syntax indicated below Note that the characters space blank _ etc are not included and consequently are not recognized by the device Inputs Outputs Factory setting Any modification Example Incorrect example Alarm input IN1 max 10 characters 0 9 A Z ALARM ALARM 1 Relay output 1 OUT1 max 10 characters 0 9 A Z BOILER PUMP 1 Relay output 2 OUT2 max 10 characters 0 9 A Z LIGHTS HOME LIGHTS Temp sensor input TEMP max 10 characters 0 9 A Z TEMPEXT TEMPERATURE Some examples of correct syntax or modifying the identification strings are shown below ALIAS
4. to electromedical equipment without checking that this is permitted Hearing aids or pacemakers or other personal medical devices may be subjected to interference when the device is in operation Consult your doctor for further information The device must not be tampered with Only replacement of the SIM card is permitted Any other modification will render the warranty void Contact the authorised service centres if necessary During operating the product may cause interference to transceiver equipment such as televisions radios PCs Move the product so that there is no more interference Dispose of the product and accessories at the end of their service life in accordance with regulations The device must not be used in the proximity of filling stations or where there is a risk of explosion It must not be used in places where chemical agents are in use and special attention must be paid to the safety regulations for environments that are saturated or potentially saturated with volatile gases or exhalations The product is fully compliant with the safety standards with regard to exposure to radiofrequency energy Building Technologies TEL50 GSM 2 2 Operating instructions i The SIM Card must always be inserted and removed when there is no power supply If not the SIM Card read interface inside the GSM module could be damaged 2 Always disable the PIN code of the SIM card If not the TEL50 GSM cannot operate D
5. Connection of stilo antenna The TEL50 GSM is supplied with its own dual band stilo antenna with the following characteristics PARAMETER CHARACTERISTICS Profile Dual Band GSM 900MHz band 890 960MHz 1 800MHz band 1710 1 880MHz Impedance 50 ohm WSVR lt 1 1 5 Type Omnidirectional Radiation diagram on horizontal plane Circular 0 5dB Radiation diagram on vertical plane 35 3dB Connector SMA male 4 4 Connection of external antenna optional In the top part of the TEL50 GSM there is an RF female SMA connector that is normally connected to the specially supplied stilo antenna Ensure that the antenna connector is securely fastened In some operating conditions the stilo antenna does not permit optimum reception of the RF signal and for this reason the TEL50 GSM can also be used with a high gain directive or omnidirectional external antenna optional If this is necessary remove the stilo antenna connector and connect the external antenna one Building Technologies a TEL50 GSM Recommendations for use of fixed or external antenna You are advised to observe the following recommendations The antenna must be placed at least 2m from any electronic equipment at least 15cm from any obstacles and in a position where there is good reception is lf malfunctioning or interference to the local electrical equipment occurs during use of the TEL50 GSM reposition the device antenna Do not use the stilo antenna if the TEL50 G
6. SM is used in enclosed or particularly shielding environments Use external antennas with characteristics that operate in the GSM Dual Band frequency band 890 960 MHz and 1710 1880 MHz with nominal impedance of 50 ohm Do not hold the antenna when the device is in use This affects the quality of the connection and requires an increase in transmission power in the TEL50 GSM Do not use the TEL50 GSM if the antenna is damaged Use of antennas prescribed by SIEMENS SpA is recommended 4 5 Insertion of SIM card The SIM reader is located in the top of the device and can only be accessed by first removing the plastic cover When correctly inserted the SIM card should be positioned as shown in the figure below IMPORTANT The SIM Card must always be inserted and removed ee when there is no power supply Only reconnect the power supply when you have finished The TEL50 GSM only works with latest generation 3 volt SIM cards If ee you possess an old SIM card contact your provider who will replace it with a latest generation one We recommend using SIM Cards that are enabled for data traffic Building Technologies 12 TEL50 GSM 4 6 Checking of indicator lamps The TEL50 GSM has 5 LED indicator lamps Three of these can be seen on the front of the device and the other two are located in the lower part and can be seen through the plastic grid LEDs On Off OUT1 conta
7. SMS command SMS reply Action ALIAS INI ALARM INI ALARM identification input 1 with ALARM ALIAS OUT1 BOILER OUT1 BOILER identification relay output 1 with BOILER ALIAS OUT2 LIGHTS OUT2 LIGHTS identification relay output 2 with LIGHTS ALIAS ANALOG TEMPEXT ANALOG TEMPEXT identification analogue input with TEMPEXT factory preset ANALOG TEMP Building Technologies 20 TEL50 GSM ALIAS SMS command SMS reply Action ALIAS IN1 INI ALARM querying of IN1 input identification string ALIAS OUT1 OUT1 BOILER querying of OUT1 output identification string ALIAS IN1 INI deleted cancels IN1 input identification string IN1 string remains active ALIAS OUT1 OUT1 deleted cancels OUT1 output identification string OUT1 string remains active strings e g OUT1 or the newly set strings e g BOILER Note After modifications are made the SMS commands for enabling querying the inputs outputs can include either factory s SMS command SMS reply Action BOILER 1 BOILER closes contact relay 1 BOILER 0 BOILER 0 opens contact relay 1 OUT1 1 OQUT1 1 closes contact relay 1 OUT1 0 OUT1 0 opens contact relay 1 LIGHTS 1 LIGHTS closes contact relay 2 LIGHTS 0 LIGHTS 0 opens contact relay 2 BOILER BOILER 0 queries the status of contact relay 1 OUT1 0 contact open BOILER OUT1 1 contact
8. TEL50 GSM S General Instructions Building Technologies G5434 TEL50 GSM en 1 AeA 1 2 1 3 1 4 1 5 2 241 2 2 3 4 4 1 4 2 4 3 4 4 4 5 4 6 5 6 6 1 6 2 6 3 7 7 1 English INTRODUCTION Copyright Trademarks Declaration of conformity Walranty cccccccees Contents of sales pack INSTRUCTIONS Safety instructions Operating instructions GENERAL INFORMATION INSTALLATION Wall mounting Electrical connections Connection of stilo antenna Connection of external antenna optional Insertion of SIM card Checking of indicator lamps TECHNICAL DATA BASIC CONFIGURATION Commands via DTMF tones Commands via SMS Temperature sensor querying EXTENDED CONFIGURATION i Creation of a qualified user list ANON FWNHHHDODA NDA HWWNHHHK 7 2 Modification of Input Output identification string 20 7 3 Alarm notification enabling 22 7 3 1 IN1 closed alarm 22 7 3 2 Temperature alarm 22 7 4 Digital I O status 24 8 ENVIRONMENTAL COMPATIBILITY AND DISPOSAL 25 9 SIGNALLING ERROR 25 Building Technologies TEL50 GSM EAL English 1 Introduction Thank you for choosing this product Please read this manual carefully to optimize use of the TEL50 GSM 1 1 Copyright Siemens S p A All rights reserved The reproduction modification or transcription of this document without prior written authorizatio
9. VDC On stand by 6 0mA 12VDC Power supply present GSM field present Status of alarm input Status of relay outputs 2 Potential free and normally open factory setting or normally closed selectable LG Ni1000 30 C 60 C 50 m max with 1 5 mm cable Potential free contact relay 250V AC 3A IP42 when correctly installed 0 50 C 20 90 R H without condensation 139 mm x 98 mm x 40 mm EN60950 2000 EN 301489 7 v1 1 1 09 2000 3 2000 EN 301419 1 v4 1 1 incl EN 301511 v7 0 1 12 2000 Building Technologies 14 TEL50 GSM 6 Basic configuration With the factory configuration the TEL50 GSM can already handle the following voice DTMF tones and SMS commands In order to operate safely and correctly the device must be correctly connected to the GSM network see par 4 6 Carefully check that this is the case during installation and before leaving the device s final location 6 1 Commands via DTMF tones Ensure that the calling telephone is enabled to send DTMF tones multifrequency Almost all phones currently on sale both for fixed network and mobiles have this option Make sure that the keypad has y read the instructions or contact the telephone manufacturer The DTMF commands sent to the TEL50 GSM will consist of an ID number for the device receiving the 7 command input or output a command number ON OFF or status request plus a control signal been set correctly To do this care
10. closed OUT1 OUT1 0 queries the status of contact relay 1 OUT1 0 contact open OUT1 1 OUT1 1 contact closed LIGHTS LIGHTS 0 queries the status of contact relay 2 OUT2 0 contact open LIGHTS OUT2 1 contact closed ALARM ALARM 0 queries the status of alarm input IN1 0 contact open ALARM IN1 1 contact closed Building Technologies 21 TEL50 GSM 7 3 Alarm notification enabling The TEL50 GSM can handle the following alarms Contact IN1 closed alarm Temperature threshold exceeded alarm 7 3 1 IN1 closed alarm This alarm may come from any device whose status needs to be monitored eg home alarm system boiler burner block etc A potential free contact must be used When the contact is closed an SMS is sent to all the users on the USER list both fixed and mobile numbers The text of the message will contain ALARM IN1 or ALARM followed by a new identification string for the IN1 input if it has been changed 7 3 2 Temperature alarm This alarm can only be generated if the temperature sensor LG Ni1000 is correctly connected to the respective input The alarm and reset values must be set according to a hysteresis cycle The values themselves will define the alarm activation logic If the ALARM value is greater than the RESET value the alarm will be triggered if the current value is higher than the alarm value Consequently the alarm will stop if the current value is lower than the reset value If the ALARM value is lo
11. ct contact Button for local activation red T closed open of relay outputs OUT2 Ol contact contact A A red rA closed open Wi IN1 alarm IE contact contact Y red O closed open Status LEDs for power Relay output 1 supply Os power supply no power Relay output 2 green T present supply Alarm input p a LEDs On Flashing 3s Flashing 1s Presence LEDs for Tel50 gsm GSM field i GSM field device field field Power supply red T transmitting present absent When first switched on the TEL50 GSM will require a few seconds to connect to the GSM network During this initial stage the front LEDs may flash on and off and the GSM field LED flash quickly one pulse every second Connection to the GSM network will be confirmed by the slow flashing of the red LED located in the bottom part of the device one flash every 3 seconds approx Check that this occurs before going on to use the TEL50 GSM Building Technologies 13 TEL50 GSM 5 Technical data Power supply Average consumption LED indicator lamps Alarm input Temperature sensor input Measuring range Length of temp sensor connections Control outputs 2 Protection rating Operating temperature Operating humidity Dimensions CE compliant Health and Safety Art 3 1 a EMC Art 3 1 b RF spectrum efficiency Art 3 2 10 30 VDC stabilized 230VAC 10 15 50 60Hz with supplied power supply In operation 700mA 12
12. elete from SIM card all lists of SMS inbox outbox sent items and disable all additional services answering service call forwarding etc Do this using a normal mobile phone SIM card non included could be for voice traffic only However we recommend using SIM cards that are also enabled for data traffic 3 Check that the area of use has adequate GSM coverage for the selected operator Check that the GSM signal is present using the special LED on the device see par 4 6 or a normal mobile phone Place the device in an area where there is good signal reception eg near a window or door If there is no signal or the signal is weak you can install an external antenna in a more favourable place using the optional lead 4 Do not power the TEL50 GSM without first connecting the stilo antenna supplied otherwise the power section of the radio transmitter in the GSM unit could be seriously damaged 5 There is no guarantee of SMS message forwarding times from and to the device commands querying or alarm reception SMS management is the exclusive responsibility of the mobile telephone network companies 6 It is advisable to set SECURITY 1 incoming call filter see par 7 1 This will limit device s answer only to user list numbers e g no answer to promotional SMS Building Technologies 6 TEL50 GSM 3 9 4oo gos General information outputs can be enabled complete separately You can enable and or disable the o
13. ful confirm or cancel ABC DEF 2 3 JKL MNO 5 6 TUV WXYZ 8 9 0 Device ID Command Control signal TEL50 GSM reply number 3 IN1 0 OFF ENTER Confirmation of dialled command ON Beep beep 4 OUT1 1 ON al CANCEL Cancellation of dialled command OFF Beep 5 OUT2 2 STATUS ERROR Beep Beep Beep Beep 6 TEMP Example OUT1 output enabled 41 OUTI Itt ENTER gt Beep Beep ON Building Technologies lt 15 TEL50 GSM When the tone is received if the command is effected the sequence of corresponding beeps ON or OFF is generated If he command is not recognized or is not applicable for example if an ON command is sent to an input 31 the ERROR one is generated If the tone is received the OFF tone is generated as confirmation of the command Call the telephone number for the TEL50 GSM and wait for the device to answer a beep after the first ring Dial the command you require from those available see table Command Reply Action 41 beep beep closes contact relay 1 eg boiler start up 51 beep beep closes contact relay 2 eg irrigation enabled 40 beep opens contact relay 1 eg boiler shut down 50 beep opens contact relay 2 eg irrigation stopped 42 beep beep contact closed beep contact open queries the status of contact relay 1 52 beep beep contact closed beep contac
14. ion etc Observe the max current rating of the electrical contacts indicated in the technical data B IN 1 P TEIE TEMP Analog input for connection of an LG Ni1000 temperature sensor Terminals 1 e 4 not used Terminals 2 and 3 connect LG Ni1000 sensor Terminal 5 connect shielding of sensor cable earth A termination resistor is connected on analog input terminals 2 and 3 It must be disconnected only if a LG Ni1000 sensor will be installed on these terminals Termination resistor gt IN1 general alarm input with potential free contact contact closed alarm present factory setting Building Technologies 9 TEL50 GSM 230 V AC L 2 3 4 5 TEMP aisis IN 1 OUT 2 OUT 1 1 2 1 2 1 2 Legend Alim Stabilized power supply 230 12VDC 1A Cl TEL50 GSM telephone remote control N1 REV Room thermostat or other electric equipment B1 LG Ni1000 temperature sensor or termination resistor S1 Potential free generic alarm contact L1 Electrical device to be activated E1 Boiler M1 Circulation pump V1 Zone valve Power supply input 12VDC 1A Button for local activation of relay outputs SIM card holder ouz oU NT TEMP 42 12 121 345 Relay Relay Alarm output output input 2 1 lt Ni1000 Building Technologies W TEL50 GSM 4 3
15. n is forbidden except as allowed under the copyright laws Copyright 2005 1 2 Trademarks TEL50 GSM is a Siemens S p A registered trademark Building Technologies sie TEL50 GSM 1 3 Declaration of conformity Siemens S p A Building Technologies Viale Piero ed Alberto Pirelli 10 20126 Milano Ml Italy declares on its sole responsibility that the following product TEL50 GSM complies with the regulations in force with reference to the R amp TTE 99 5 EC directive and above all with the following standards Health and Safety Art 3 1 a EN 60950 2000 EMC Art 3 1 b EN 301489 7 v1 1 1 09 2000 RF spectrum efficiency Art 3 2 EN 301419 1 v4 1 1 03 2000 incl EN 301511 v7 0 1 12 2000 QE Building Technologies 2 TEL50 GSM 1 4 Warranty This product is guaranteed against any material and manufacture defects SIEMENS reserves the right at its own discretion to repair or replace faulty products The warranty is deemed null and void if the fault is caused by improper use or by an operating procedure that is not included in this manual The warranty will not cover faults caused by improper and careless use damage caused by atmospheric agents acts of vandalism material that is subject to wear and tear 1 5 Contents of sales pack User Manual this manual TEL50 GSM device 230VAC 12VDC 1A power supply GSM stilo antenna Building Technologies 3 TEL50 GSM 2 Instructi
16. ons In order to use the product safely and efficiently please read the following instructions carefully before use The product may only be employed for the use for which it has been conceived and manufactured Any other use shall be considered the user s sole responsibility 2 1 Safety instructions Installation programming and commissioning should only be carried out by qualified operators these operators must be physically and mentally capable of performing the task Commissioning may only occur after the product has been correctly installed For this reason users must carefully perform all the operations described in the manual supplied SIEMENS will disclaim all responsibility for any failure breakage accident etc due to the lack of knowledge of or failure to observe given instructions The same shall apply to any unauthorized changes SIEMENS reserves the right to change the product for constructive or commercial reasons without being obliged to update reference manuals promptly The TEL50 GSM uses the GSM standard for mobile telephony As a result it cannot be used in areas that are outside the system coverage area Since the GSM system is a radiofrequency RF technology it may interfere with other telephones or create problems with electronic devices that are not adequately protected from RF energy Building Technologies 4 TEL50 GSM Precautions H Do not install and use the product in close proximity
17. puts OUT1 and OUT2 can be redefined The factory setting has the following conditions The alarm input IN1 is active high ie the alarm is sent with the input IN1 closed The control outputs OUT1 and OUT2 are normally open For input IN1 the alarm status active low or high for sending notification to all the users is defined whereas for the outputs the idle state is defined normally open or closed These settings can be modified as shown in the table below SMS command SMS reply Action DIGITAL IN1I ALARM 0 IN1 ALARM 0 input IN1 active open DIGITAL INI ALARM 1 IN1 ALARM 1 active input IN1 closed factory setting DIGITAL OUTI CONTACT 0 OUTI1 CONTACT 0 control output 1 normally open factory setting DIGITAL OUT1 CONTACT 1 OUTI CONTACT 1 control output 1 normally closed DIGITAL OUT2 CONTACT 0 OUT2 CONTACT 0 control output 2 normally open factory setting DIGITAL OUT2 CONTACT 1 OUT2 CONTACT 1 control output 2 normally closed Building Technologies 24 TEL50 GSM 8 Environmental compatibility and disposal This product has been developed and constructed using materials and processes that take account of environmental issues Refer to the following notes for disposal of the product at the end of its service life or if it needs to be replaced For disposal purposes this product is classified as an electrical and electronic device do not dispose of it as household waste especiall
18. t open queries the status of contact relay 2 32 beep beep contact closed beep contact open queries the status of alarm input 62 beep beep temp alarm active beep temp alarm not active queries the status of temperature alarm 6 2 Commands via SMS Commands and queries via SMS must be sent to the TEL50 GSM with the following syntax all letters must be uppercase no spaces at top or bottom of message Observe spacing as indicated An unexpected command for example IN1 1 an input cannot be enabled or with incorrect syntax for example use of lowercase characters or in any case not recognized by the apparatus produces a reply SMS with message ERROR xx see par 9 Error signalling Make sure that the source number is in the USER list see par 7 1 or if it is not that the incoming call control is not enabled SECURITY 0 factory disabled Building Technologies 16 TEL50 GSM SMS text SMS reply Action OUT1 1 OUT1 1 closes contact relay 1 OUT1 0 OUT1 0 opens contact relay 1 OUT2 1 OUT2 1 closes contact relay 2 OUT2 0 OUT2 0 opens contact relay 2 OUT1 OUT1 0 or OUT1 1 _ queries the status of contact relay 1 OUT1 0 contact open OUT1 1 contact closed OUT2 OUT2 0 or OUT2 1 _ queries the status of contact relay 2 OUT2 0 contact open OUT2 1 contact closed IN1 IN1 0 or IN1 1 queries the status of alarm input IN1 0 contact open _IN1 1 contact closed
19. this section The numbers entered must have a minimum length of 6 numbers to be considered valid If the security parameter is enabled SECURITY 1 the calls coming from numbers not included in the list will not be accepted If there are no configured users or the security parameter is disabled SECURITY 0 the caller s number will not be checked The telephone number and type of user see below configuration valid only for commands sent by SMS must be entered for each user All the users in the list will receive notification of temperature alarms if a remote temperature sensor is present and alarms generated by closure of input IN1 Users can be entered with three different profiles Administrator extension 1 This type of user has full control of the device and can therefore insert and remove functional parameters control and check states of inputs and outputs and receive notification of alarms and temperature readings User extension 2 This type of user has partial control of the device and can therefore only control and check states of inputs and outputs receive notification of alarms and receive temperature readings He she cannot change or query functional parameters Notify extension 3 This type of user has no control of the device and can therefore only receive notification of alarms TEL50 GSM will not accept and therefore will not answer to call or SMS coming from this type of user Building Technologies 18 TEL50 GSM
20. utput locally using the button on the device according to the ollowing binary sequence O lt Cycle OUT1 OUT2 1 OFF OFF 2 ON OFF 3 OFF ON 4 ON ON The device is suitab emperature controllers REV16 REV23 REV33 e for use with the Chronogyr room REV100 REV200 and new REV13 REV17 REV24 REV34 he TEL50 GSM phone remote control has been designed for remote operation of electrical or electro hydraulic equipment uch as room thermostats boilers burners heaters zone valves circulation pumps irrigation systems etc It is particularly uitable for holiday home installations where there is no fixed telephone network he remote control can only be used through the GSM mobile network Commands can be sent via the fixed telephone etwork DTMF tones or GSM mobile network DTMF tones and SMS messages with preset syntax The TEL50 GSM also lows connection of an LG Ni1000 temperature sensor optional and forwarding via SMS subject to special querying of the temperature value measured at that time The device can handle both a temperature threshold exceeded alarm adjustable and a general alarm to be connected to the respective input on the terminal box In both cases activation of the alarm generates a specific SMS that is sent to a predefined user list The 2 control Building Technologies TEL50 GSM 4 Installation Comply with the permitted temperature and humidit
21. wer than the RESET value operating will be reversed The factory settings are ALARM 5 C and RESET 6 C frost protection The user can modify the alarm and reset thresholds as shown in the examples below When an alarm is triggered an SMS is sent to all the users on the USER list both fixed and mobile numbers The text of the message will contain ALARM TEMP or ALARM followed by a new identification string for the ANALOG TEMP analogue input if it has been changed Building Technologies 22 TEL50 GSM Example SMS command SMS reply Action A allarme ON TEMP ALARM 5 ALARM 5 alarm threshold set to 5 C impostazione TEMP RESET 6 RESET 6 reset threshold set to 6 C di fabbrica OFF So 5 6 temp SMS command SMS reply Action A allarme ON TEMP ALARM 20 ALARM 20 alarm threshold set to 20 C TEMP RESET 19 RESET 19 reset threshold set to 19 C OFF 19 20 temp Alarm notification is au omatically enabled when the ALARM and RESET thresholds are set The identification string of the analogue input can be modified if necessary SMS command SMS reply Action ALIAS ANALOG TEMPEXT ANALOG TEMPEXT identification TEMP input with TEMPEXT Note if there is no ALIAS the ANALOG factory identification is used Building Technologies 23 TEL50 GSM 7 4 Digital V O status In this section the idle and or operating condition of the digital input IN1 and relay out
22. y as far as the printed circuit is concerned Comply with all local laws that are in force Reuse raw materials as much as possible in order to minimize environmental impact Use local tips and waste recycling companies or contact suppliers or manufacturers to return used products or obtain additional information on environmental compatibility and waste disposal The TEL50 GSM packaging is reusable Keep it for future use or if the product needs to be returned to the supplier 9 Signalling error TEL50 GSM signals via SMS the following errors Error 01 Sintax error or unknow command Error 04 Non active Error 02 __ Number length shorter than 6 characters Error 05 Non active Error 03 Position or User number not correct Error 06 Alias not correct or unknow Building Technologies 25 TEL50 GSM Siemens A E Electrotechnical Projects amp Products Infrastructure amp Cities Sector Building Technologies Division Control Products and Systems Agisilaou Str 6 8 GR 151 23 Athens Greece Building Technologies Greece internet http www siemens gr buildingtechnologies Product information on internet http www siemens com hit ar
23. y conditions see Technical Data 4 1 Wall mounting Mount the device on the wall or 3 module flush mounted box 503 type using the special holes in the rear part of the container During installation be careful not to damage the internal components 4 2 Electrical connections To make the electrical connections remove the plastic cover of the TEL50 GSM when you have finished remember to put the cover back into position Make the electrical connections as shown in the enclosed diagrams The device must be powered with direct current with nominal stabilized voltage between 10 and 30 V by a source that can supply at least a 1A current Only use the included standard mains supply 230Vac 50Hz and connect it to the respective terminals in the device using the correct polarity The power supply input is protected against polarity reversal PE Ne sae e a s a l Building Technologies 8 TEL50 GSM Connecting terminals _ Power supply input Only use the supplied power supply Use of incompatible power supplies may cause irreversible damage to the device Check the correct polarity B QUT1 Relay output 1 our Qut Potential free relay contact for control of special devices boiler zone valve heater etc Observe the max current rating of the electrical contacts indicated in the technical data ga OUT2 Relay output 2 Potential free relay contact for control of other devices lights irrigat

Download Pdf Manuals

image

Related Search

Related Contents

Trevi DPH 2203  Sim2 Multimedia HT300 PLUS Projector User Manual    Philips 2800 series Steam iron GC2821/02  www.pce-iberica.es  Mode d`emploi original C-KLR  Vulcan-Hart ML-114950 User's Manual  AIDE M 864 HO NB - Impact Distribution  Keysight U1117A IR  manuale utente italiano user manual english manuel  