Home

User`s Manual for

image

Contents

1. Blank check before programming Disable Verity after reading Enable Verify Twice v V enfy options 4 20 5 50 Programming parameters C User program memory and ID locations Data EEPROM memory C Configuration bits Set desired operations for the device and then click on OK button 8 customize device use menu Alt S 20 dos 4E NEG ELNEC s r o ViewEdit Contiz bits and ID locations ID14D4 105108 Oscillator Watchdog T imer 1 Enable Fower up Timer 1 Disable gt Brown out Reset 1 Enable v OSCSENS 1 Disable Stack Overflow Reset gt 2 1 2 multiplexed with v Watchdog Postscaler BOR 11 Ybor set to 2 04 e LVF 1 Enable Background debugger 1 Disable 1111 CPD CPB 11 WRT3 WRTO 1111 WRTD WRTB WRTC 111 EBTRB 1 Set desired settings for the device and then click on OK button Note Menu Device operation options and lt Alt S gt depend on the selected device 9 Save project click on esl icon and select destination folder write a description of project etc You can make a project on other ELNEC programmers BeeProg2 too For more details see Help for PG4uw single site driver and User manual for all ELNEC programmers The latest manual may be found at www elnec com part download Production mode
2. Buffer operations e view edit find replace e fill copy move byte swap word dword split e checksum byte word e print File load save e no download time because programmer is PC controlled e automatic file type identification recognition 15 ELNEC s r o Supported file formats e unformatted raw binary e HEX Intel Intel EXT Motorola S record MOS Exormax Tektronix ASCII SPACE HEX ASCII HEX e Altera POF JEDEC ver 3 0 A e g from ABEL CUPL PALASM TANGO PLD OrCAD PLD PLD Designer ISDATA etc e JAM JEDEC STAPL Format JBC Jam STAPL Byte Code STAPL STAPL File JEDEC standard JESD 71 e VME ispVME file VME2 0 VME3 0 GENERAL e operating voltage AC 90 264V 47 63Hz e power consumption max 300W active e dimensions 625x465x115 mm 24 6x18 3x4 5 inch e weight programmer 14 9kg 32 85 Ibs e temperature 5 C 35 C 41 F 95 F e humidity 20 80 non condensing Package included Standard accessories e BeeHive208S programmer e diagnostic POD for ZIF socket selftest of the programmer 1x e diagnostic POD for ISP connector selftest of the programmer 1x e 48 Pins Calibration test POD Type e ISP cable 8x e anti dust cover for ZIF socket 8x e user manual both on CD and printed form e software e registration card e calibration test report e transport case Bonus pack e ESD wrist strap with cord and banana plug e Vacuum pen e Gift Surprise Additional
3. User s Manual for BeeHive208S Extremely fast universal 8x 48 pindrive Stand Alone concurrent multiprogramming system 44 ELNEC s r o Presov Slovakia December 2010 ELNEC s r o This document is copyrighted by ELNEC s r o Presov Slovakia All rights reserved This document or any part of it may not be copied reproduced or translated in any form or in any way without the prior written permission of ELNEC s r o The control program is copyright ELNEC s r o Presov Slovakia The control program or any part of it may not be analyzed disassembled or modified in any form on any medium for any purpose Information provided in this manual is intended to be accurate at the moment of release but we continuously improve all our products Please consult manual on www elnec com ELNEC s r o assumes no responsibility for misuse of this manual ELNEC s r o reserves the right to make changes or improvements to the product described in this manual at any time without notice This manual contains names of companies software products etc which may be trademarks of their respective owners ELNEC s r o respects those trademarks COPYRIGHT 1997 2010 ELNEC s r o ZLI 0316A ELNEC s r o Table of contents 0 4 2085 elements ccccccssscecceseecse
4. Copy button Change dir button is used to change current directory to directory selected in Directory list on the left side of dialog When folder is selected Change dir button jumps from current directory one level one folder up Note The drive combo box is automatically refreshed each time it is dropped down It is useful for loading project files from USB key which can be plugged temporarily to USB port of standalone programmer and consequently the new drive letter assigned with USB key will appear in list of available drives When option 2 is selected the dialog with a list of project files present in Projects folder will appear User can select desired project and delete selected project by clicking on Delete button The dialog can be closed by Cancel button Also basic information about selected project file can be displayed by clicking File info button File Make Job Report Job Report Samsung K9GBGOBUOM TSO Elnec Job Report created at 2007 07 03 year month day 03 23 08 Project Name E Programmerik9g8g08u0m epr Project Date 2007 06 27 15 47 44 Protected Mode Disabled Software Revision PgduwlMC ver 2 39 06 2007 Programmer BeeHiwe8S s n 586 0000 1 Job Start Time 2007 07 03 07 17 02 Job End Time 2007 07 03 09 23 08 Job Elapsed Time 2 Hours 126 Minutes amp Seconds Device Name Samsung K9G8G08Ll M TSOP4 Device Size 100CE813Ch When this menu command is selecte
5. ELNE ELNEC s r o Remote control Administering of BeeHive208S Stand Alone multiprogramming system is performed through Microsoft Remote Desktop Connection Remote desktop offers fast and comfortable way to update software control software and system distribute project files Find and run Remote Desktop Connection program on your computer In Computer field enter IP address from Welcome screen of standalone programmer w Remote Desktop Connection Remote Desktop Connection Computer 182 158 0 145 When communication is established enter administrator credentials Remote Desktop Connection Enter your credentials For 192 168 0 145 These credentials Will be used when you connect to the remote computer User name Q5 admin v Remember my password Because Windows allows only one user connected at a time next message may be showed Logon Message The user OEM ESP49TO3Z5LYoperator is currently logged on to this computer If you continue this user s Windows Session will end and any un saved data will be lost Do you want to continue 41 SRE s r o Warning Connecting to programmer time when programming devices is running programming will be immediately terminated your devices may not be fully programmed Restart computer after you finish remote administering Because work with remote desktop is similar to working on local station please continu
6. There are two modes Mode A without external display keyboard and mouse connected to BeeHive208S Programming control is only via build in display with touch screen Mode B with external display keyboard and mouse connected to BeeHive208S Programming control is via Pg4uwMC displayed on external display 21 ELNEC s r o Warning External display keyboard and mouse not needed in this mode This part of the software is focused on the easy monitoring of high volume production operations via graphical control unit with touch screen The user can control the following basic operations load project file connect disconnect programmer sites select desired device master operation blank check verify program erase start stop device operation on connected programmer sites set some advanced options to customize available settings for example Automatic YES Function create Job report create Problem report copy project file s from external drive for example from network drive USB key etc to the standalone s local Projects folder see the progress of device operation including statistics information serialization Step by step instruction Starting Stand Alone multiprogramming system 1 2 6 Check if the power switch placed at back side of programmer near power supply connector is on position 0 Plug the power cord in to the programmer power supply connector and turn on the programmer by the pow
7. be inserted in the socket properly independently of the status of other programming modules This results in seven programming modules working while you replace the programmed chip in the eighth Graphical control unit with touch screen provides basic control and easy monitoring of the programming flow Modular construction of hardware the programming modules work independently allows for continuing operation when a part of the circuit becomes inoperable It also makes service quick and easy Hands free operation asynchronous and concurrent operation allows a chip to begin programming immediately upon insertion of a chip The operator merely removes the finished chip and inserts a new chip Operator training is therefore minimized BeeHive208S supports all kinds and types of silicon technology found in today s and tomorrows programmable devices without family specific modules You can be sure that new device support requires the software to be updated and if necessary simple mE Rng 4 ELNEC s r o package converter programming adapter therefore the ownership costs are minimized Using built in in circuit serial programming ISP connector the programmer is able to program ISP capable chips in circuit BeeHive208S provides very competit
8. loading of file It is possible to use Jam files JEDEC standard JESD 71 and VME files The rich featured auto increment function enables one to assign individual serial numbers to each programmed device or simply increments a serial number or the function enables one to read serial numbers or any programmed device identification signatures from a user created file The software also provides a lot of information about programmed device As an example the drawings of all available packages explanation of chip labeling the meaning of prefixes and suffixes on the chips 17 lH o Load Save Load prj Save prj e lt a mi Log window Addresses Device start Device end 00 Buffer start Split None Insertion test Insertion test Device ID chec Command executi Blank check be Verify after r Verify Twice Verify options End of optio Selected device Buffer checksum i gt gt Log file creat Log file name C Log file mode Ap Microc hip Microchip Microchip Microchip Microchip Microchip Microchip Addresses hex Or Size Device x8 _ 18888 Buffer x8 _ 18888 Fie x8 an Serialization None Filename Microchip 88 Common information Package details DIP 28 300mil FERIER 2 54 0 100 Part number description ELNEC s r o ad Search pic18f242 FFFF FFFF Split Non
9. settings Three modes of Automatic YES function are available 31 ELNEC s r o Automatic YES Is always On Automatic YES Is always Off e Use Project settings Automatic YES setting depends on relevant settings stored in project file When Automatic YES mode is On programmer sites are scanning their device sockets after device operation is completed The control program can detect removing of programmed device and insertion of new device and afterwards automatically start repeat recent operation on new device So operator does not need to press any key or button to program next device When Automatic YES mode is Off operation on next device can be started manually by pressing the YES button near each programmer site socket Each programmer site has its own YES button Status of the active Automatic YES function is displayed on the bottom left side of LCD main screen with label Automatic YES Is On by following File Device Programmer Options Help ite ET Please insert new device into sock 1 Please insert a new device into sock Next serial value Statistics None Good Total 0 Ctdn Disabled Device Macroniz MEZBFEAOC3BB TSOP48 Project m 28f640c3bb epr Checksum 7FS00000h Automatic YEST ie On If the Automatic YES function is Off no label about Automatic YES is displayed Serialization E 2 EE ETT ESI ET mm mp mA For more details about Automatic YES
10. 023 SITE 1 b lt gt Command displays content of current Log window At top right corner is the button x which is used for closing the Log window and displaying of main screen Options Protected mode Protected mode is special mode of the program When the program is in Protected mode there are disabled certain program operations and commands Protected mode is used to prevent the operator from modifying program or device settings due to insignificance Protected mode is suitable especially for the programming of a large amount of the same type of devices Protected mode can be activated by this menu option or by loading project file that has activated Protected mode Protected mode settings are saved to configuration ini file of Pg4uwMC During next start of program Pg4uwMC the Protected mode settings from ini file are used When Protected mode menu command is used password dialog will appear User has to enter password twice to confirm the password is correct After successful password confirmation program switches to Protected mode 37 ELNEC s r o File Device Programmer Options Help Site Status Serialization Set password for Protected mode Password Pk Canfirm password C Keep Load project operation allowed Checksum There is also available one special option Keep Load project operation allowed The option is set to disabled at default it means the Load
11. 11 series HC908 series both 5 wire All wire HCS08 HCS12 e Microcontrollers NEC uPD7xxx series e Microcontrollers Philips LPC2xxx series LPC series 89xxx series e Microcontrollers Scenix Ubicom SXxxx series e Microcontrollers Tl MSP430 both JTAG and BSL series MSC12xxx series e PLD Lattice ispGAL22xV10x ispLSI1xxxEA ispLSI2xxxE ispLSI2xxxV ispLSI2xxxVE ispLSI2xxxVL M4 xx xx M4LV xx xx M4A3 xx xx M4A5 xx xx LC4xxxB C V ZC e Various PLD also by JAM player JTAG support e Altera MAX 3000A MAX 7000A MAX 7000B MAX 7000S MAX 9000 MAX II e Xilinx XC9500 XC9500XL XC9500XV CoolRunner XPLA3 CoolRunner l Notes For all supported devices see actual Device list at www elnec com Package support e support all devices in DIP with default socket e package support includes DIP SDIP PLCC JLCC SOIC SOP PSOP SSOP TSOP TSOPII TSSOP QFP PQFP TQFP VQFP QFN MLF SON BGA EBGA FBGA VFBGA UBGA FTBGA LAP CSP SCSP etc e support devices in non DIP packages up to 48 pins with universal adapters e programmer is compatible with third party adapters for non DIP support Programming speed Device Size bits Operation Time PIC32MX360F512L microcontroller Conditions PG4uw version 2 64 Notes e t is important to know we always use random number patterns for programming speed tests Some of our competitors use a sparse pattern where only some non blank data is progra
12. B2 10k 9 AX ELNEC s r o CC1 1n RC1 1k3 RC2 22k RD1 22k CE1 1n RE1 1k3 C Connection of pins 15 and 16 when are configured as logical signal needed for ISP programming D E when pins 15 and 16 are configured as status of LED OK and LED ERROR D before first action with desired ISP device E after first action with desired ISP device Notes When LED OK or LED ERROR ON shine this status is presented as logical H level of H is 1 8V 5V depend on H level of desired ISP device When LED OK or LED ERROR OFF not shine this status is presented as logical L level of L is OV 0 4V The above mentioned values are provided to understand and also to exactly calculate the value of resistors which isolate separate the programmed chip and target system Specification of ISP connector pins depends on the device which you want to work with You can find it in the control SW for programmer Pg4uw menu Device Device Info Ctri F1 Note the ISP programming ISP option of respective device must be selected It is indicated by ISP suffix after the name of selected device These specifications correspond with application notes published by device manufacturers Application notes can be found on www elnec com section Support Application Notes Note Pin no 1 is signed by triangle mark on ISP cable connectors BeeHive208S ISP cable Warnings e Use only ISP cable from delivery package When you use oth
13. ELAN EM78Pxxx e Microcontrollers MDT 1xxx and 2xxx series e Microcontrollers Microchip PlCmicro PIC10xxx PIC12xxx PIC16xxx PIC17Cxxx PIC18xxx PIC24xxx dsPIC series e Microcontrollers Motorola Freescale 68HC05 68HC08 68HC11 HCS08 HCS12 series e Microcontrollers Myson MTV2xx 3xx 4xx and 5xx series e Microcontrollers National COP8xxx series e Microcontrollers NEC uPD78xxx series e Microcontrollers Novatek NT68xxx series e Microcontrollers Scenix Ubicom SXxxx series e Microcontrollers SGS Thomson ST6xx ST7xx ST10xx STR7xx series e Microcontrollers Tl MSP430 and MSC121x series e Microcontrollers ZILOG Z86 Z89xxx and Z8xxx series 13 ELNEC s r o eMicrocontrollers other EM Microelectronic Fujitsu Goal Semiconductor Hitachi Holtek Princeton Macronix Winbond Infineon Siemens NEC Samsung Toshiba Notes e For all supported devices see actual Device list at www elnec com Programmer through ISP connector e Serial E E PROM IIC series MW series SPI series KEELOQ series serial data Flash PLD configuration memories e Microcontrollers Atmel AT89Sxxx 905 ATtiny ATmega series e Microcontrollers Cypress CY8C2xxxx e Microcontrollers Elan EM78Pxxx EM6xxx series e Microcontrollers EM Microelectronic 4 and 8 bit series e Microcontrollers Microchip PlCmicro PIC10xxx PIC12xxx PIC16xxx PIC17xxx PIC18xxx PIC24xxx dsPIC series e Microcontrollers Motorola Freescale HC
14. Hive208S Stand Alone multiprogramming system is powerful programmer equipped with Windows XP Embedded operating system OS There are two major kinds of administration of the OS network and local OS is configured with two users accounts e admin e operator Credentials for BeeHive208S Stand Alone multiprogramming system users are Login Password Administrator admin saadmin Operator operator saoperator Network administration Connecting to network OS in programmer is configured for operating with TCP IP network To obtain correct IP address the configured DHCP server must run in your local network when programmer is starting After programmer is started it will show Welcome About screen On bottom part of screen in line IP address is the address obtained from DHCP server When IP address is equal to 127 0 0 1 then no network cable is connected DHCP server is not running when device start or other kinds of error occur refer to troubleshooting chapter 4 5 Pg4uwMC zi wer 2 B4 11 2008 Universal stand alone multiprogramming system c 1992 2009 by ELNEC s r o web http www elnec com Programmer type BeeHrvez2085 Number of Sites available 8 Operating system Windows 24 v5 1 Build 2600 Service Pack 2 Processor Intel 5 15 56 Frequency 2400 2400 06 MHz Physical RAM memory 1000 MB Computer name OEM USELHTPPFFA IP address 192 168 0 146 Date amp Time 11 3 2008 3 33 40 AM 40
15. OS CMOS 28xxx 28Cxxx 27 EExxx series with 8 16 bit data width eFlash EPROM 28Fxxx 29Cxxx 29Fxxx 29BVxxx 29LVxxx 29Wxxx 49F xxx series from 256Kbit to 32Mbit with 8 16 bit data width full support for LV series e Serial E E PROM 24Cxxx 24F xxx 25Cxxx 45Dxxx 59Cxxx 25Fxxx 25Pxxx 85xxx 93Cxxx NVM3060 MDAxxx series full support for LV series e Configuration EE PROM XCF xxx XC17xxxx XC18Vxxx EPCxxx AT17xxx 37LVxx 1 Wire E E PROM DS1xxx DS2xxx e PROM AMD Harris National Philips Signetics Tesla eNV RAM Dallas DSxxx SGS Inmos MKxxx SIMTEK STKxxx XICOR 2xxx ZMD U63x series e PLD Altera MAX 3000A MAX 7000A MAX 7000B MAX 7000S MAX7000AE MAX II ePLD Lattice ispGAL22V10x ispLSI1xxx ispLSI1xxxEA ispLSI2xxx ispLSI2xxxA ispLSI2xxxE ispLSI2xxxV ispLSI2xxxVE ispLSI2xxxVL LC4xxxB C V ZC M4 xx xx M4A3 xx xx M4A5 xx xx M4LV xx xx e PLD Xilinx XC9500 XC9500XL XC9500XV CoolRunner XPLA3 CoolRunner ll eother PLD SPLD CPLD series AMI Atmel AMD Vantis Gould Cypress ICT Lattice NS Philips STM VLSI TI e Microcontrollers 48 series 87x41 87x42 87x48 87x49 87x50 series e Microcontrollers 51 series 87xx 87Cxxx 87LVxx 89Cxxx 89Sxxx 89LVxxx all manufacturers Philips LPC series e Microcontrollers Intel 196 series 87C196 KB KC KD KT KR e Microcontrollers Atmel AVR AT90Sxxxx ATtiny ATmega series e Microcontrollers Cypress CY7Cxxxxx CY8Cxxxxx e Microcontrollers
16. Use Log file test truncating when file size limit iz reached M asimum Log file size 4000 kB 200 kB 200000 kB Amount of truncated text Log file is text file containing information about Pg4uwMC control program operation flow which means information about loading project files device operation types and device operation results ELNEC s r o Main Log file name in Stand Alone programmer can not be modified by user it has defined value E Logs reportmc log where drive E is placed on built in disk of Stand Alone programmer Multiprogramming system generates a few Log files One main Log file for program Pg4uwMC and Log files for each of the running Programmer Sites Each site has its own Log file The name of the site s Log file has the same prefix as the name of the Log file specified in the edit box Log file The file name prefix is followed by the number of the site in the form of _ lt Snum gt All Log files are placed into the folder E Logs reportmc log where drive E is placed on built in disk of standalone programmer The Log file names used are reportmc log Pg4uwMC main Log file reportmc_ 1 log Site s 1 Log file reportmc_ 2 log Site s 2 Log file reportmc_ 3 log Site s 3 Log file and so on Following options can be set for Log file creation e option Append Log file sets usage of Log file Log file will be created after the first restart of Pg4uwMC For all following executions of Pg4uwMC the existing Log
17. ccepted by pressing touching Accept If no complete programmer was found then No Programmers found message will be displayed in table Search results and button Accept will be disabled 22 ELNEC s r o 9 If search result is No Programmers found please try to turn off Stand Alone programmer by menu File Shut down computer turn off the power button on the back Side of programmer wait for 15 seconds or more and start programmer again If the search result is still No Programmers found please refer to troubleshooting documentation Starting programmer sites 10 Each programmer site is uses its own hidden control application Pg4uw 11 To start the hidden applications of control programmer sites use menu Programmer Connect Sites 12 The Connecting sites indicator is displayed during connection of sites Additional information about site connection progress is displayed for each site in panel Status on main screen 13 Programmer sites are numbered from 1 to 8 in direction of physical placement of programmer sites from left to right 14 When connection process of programmer sites is complete indicator Connecting Sites will be hidden Panel Status will contain information about each site Loading project file 15 When site status after connection is Ready or No project file is loaded user can begin the Load project operation accessible from menu File Load project The project fil
18. ct e other text describes current status of Site s for example Loading data from disk to buffer Programming device 85 Programming device OK Please insert a new device into socket 25 ELNEC s r o Next serial value When serialization is active the panel displays current serialization mode and serialization number or label that will be used for next device programmed Recent serial numbers used for each device are displayed in table Site and serialization status in column Serialization Statistics Panel contains information about the number of device operations processed and actual count down status For more details see Statistics dialog menu Options Statistics Recently selected Device name Manufacturer and name of recently selected devices Recent Project name Currently loaded project file name Checksum of data stored in data buffer for currently selected device Button Run can be operation name for example Program Verify Erase Click on button Run will start selected device operation for all connected programmer sites Button can be used when no device operation is running on any programmer site Button Stop Click on button Stop will stop executing of currently running device operation on all connected programmer sites Menu File File Load project This menu command opens dialog Load project where user can choose from which location the project file has to be loaded an
19. current directory one level one folder up Note The drive combo box is automatically refreshed each time it is dropped down It is useful for loading project files from USB key which can be plugged temporarily into USB port of standalone programmer and consequently new drive letter assigned with USB key will appear in list of available drives File Manage projects Manage project dialog offers two options Manage projects Please select one of following actions Copy project file from another location il to Projects folder Delete project file from Projects folder 1 Copy project file from another location to Projects folder 2 Delete project file from Projects folder ELNEC s r o Copy project file to Projects folder Delete project file from Projects folder Look in fo Data vw Select project file M k3fig Bu m with ecc epri me28t640c3bb eprj Directory qi Praq k3rta 8u m epri kS3rta Su m with kSig amp g Sulm epr EU E AE without it and idi emx2ofb40c3bb epr 2 3 Director E Projects Drive g Data 71 171 MB of 74 651 MB free Dine etal L io eee ome ies When option 1 is selected the dialog with list of project files at specified drive and folder will appear User can select desired drive folder and project file and copy the selected project to the Projects folder by clicking
20. d a Job Report will be created and displayed in the Job Report window Before displaying the Job Report the information message is displayed The information message also contains information about the file name to which the Job Report will be saved 28 ELNEC s r o File Switch to Engineering mode Device Programmer Options Help Load project haar Manage projects Make Job Report Switch to Engineering mode Shut down computer d Fait TotatD an Disabled Device Samsung EKIGSG08U0M TSOP48 Project k388g908u m epr Checksum Command is used to start Pg4uw control program in Engineering mode In this mode user can use Pg4uw software to select any device from the list of supported devices set options for the device load data files for device test the device operations on any programmer site and create a project file which can be used in production mode More information about Engineering mode is available in chapter Engineering mode To switch back to production mode just close Pg4uw control program and run program Pg4uwMC by double clicking on Pg4uwMC icon on the Desktop Note Engineering mode requires connection of external VGA monitor keyboard and mouse Do not use this menu option without these peripherals connected and working File Shut down computer Command is used to close control program and to shut down built in computer It is similar to command Shut down in Microsoft Windows operat
21. d load selected project Load Project Please select one of following actions E Load project from Projects folder Load project from another location Two options are available 1 Load project from Projects folder 2 Load project from another location 26 ELNEC s r o Load project from Projects folder Load project Select project file Look in NEMPE Directory E Projects B files 3 k8fig Bu m with ecc epri g gu m epri maz8r amp 4 c3bb epri KSA g0ulm_with_ecc epr kSg8g08u0m pr kSg8g08u0m_with_itd epr mwa28FB4Uc3bb em epr mwa28F54Uc3bb it epry Director E Projects Drive Data 71 171 MB of 74 651 MB free Drive e 71 443 MB af 74 651 MB free When option 1 is selected dialog with list of project files present in Projects folder will appear User can select desired project and load the project by clicking on Load button Dialog can be closed by Cancel button Also basic information about selected project file can be displayed by clicking File info button When option 2 is selected a dialog with list of project files at specified drive and folder will appear User can select desired drive folder and project file and load the project by clicking on Load button Change dir button is used to change current directory to directory selected in Directory list on the left side of dialog When folder is selected Change dir button jump up from
22. e socket accepts both 300 600 mil devices up to 48 pin e pindrivers 48 universal e VCCP VPP1 VPP2 can be connected to each pin e perfect ground for each pin e FPGA based TTL driver provides H L CLK pull up pull down on all pindriver pins e analog pindriver output level selectable from 1 8 V up to 26V e current limitation overcurrent shutdown power failure shutdown e ESD protection on each pin of socket IEC1000 4 2 15kV air 8kV contact e continuity test each pin is tested before every programming operation ISP connector e 20 pin male type with miss insertion lock e 6 TTL pindrivers provides H L CLK pull up pull down level H selectable from 1 8V up to 5V to handle all low voltage including devices e 1 voltage range 2V 7V 100mA can be applied to two pins ma vv rO 12 ELNEC s r o e programmed chip voltage with both source sink capability and voltage sense e 1x VPP voltage range 2V 25V 50mA e target system supply voltage range 2V 6V 250mA e ESD protection on each pin of ISP connector IEC1000 4 2 15kV air 8kV contact e two output signals which indicate state of work result LED OK and LED Error active level min 1 8V e input signal switch YES equivalent active level max 0 8V DEVICE SUPPORT valid for each programming module Programmer eEPROM NMOS CMOS 2708 27xxx and 27Cxxx series with 8 16 bit data width full support for LV series e EEPROM NM
23. e CheckSum OOFFOOO0h See also Device info lt Ctrl F1 gt P LUYULS UN IL S Microcnip KEE Make a project 1 Connect external display keyboard and mouse to PC connectors on back side of programmer Turn on programmer Se Iu Programmer Run the control program double click on Find BeeHive208S Site programmer Ctrl F or right click on panel File Buffer Device Programmer ELNEC s r o P L Load Save aja A Log window I t gt gt IDIR Find programmer Programmer BeeHive2085 Site BeeHivedS Site BeePrag2 O SmattPrag2 O 51 2 O MEMprog2 MEMprogL BeeHive204 Site 4 Site PlKprog2 MEMprog SEEprog BeeProg JetProg lt LabProg 48LV PREPROM 02aLV PIKprog 514VRprog Device BeeHived Site LabProg SmartProg 51 PlKprog Buffer File O Search all CheckSum 007F800 Serialization None Split None Port USB LPT1 378h Special LPT All ports for special port 200 Force SPP mode for LPT Establish communication Automatic Manual of eload Count down Automatic Connect Cancel Filename Select BeeHive208S Site and then click on Connect button 4 Select site PG4UW v2 64 11 2009 universal control program for programm
24. e can be loaded from default directory Projects or from any other location for example from USB key For more details about Load project refer to the chapter Menu File and Load project When Load project operation is successfully done for all Sites the Ready status must be displayed in panel Status on touch screen for all connected Sites If there are some Sites with different status use troubleshooting documentation to resolve the problem Selection of predefined device operation 16 Use menu Device Predefined operation to select device Master operation Following Master operations are available Blank check Verify Program Erase For more details about predefined device operations see chapter Menu Device Predefined operation Insertion of devices in programmer sockets and start device operations 17 Insert devices into programmer sockets and press Run operation button on touch screen operation means predefined operation for example when predefined operation is Program device the caption of button Run will be Run Program 18 Selected device operation including suboperations that are part of predefined device operation will start Progress of operations is displayed in panel status for each programmer site You can use some special features of Stand Alone multiprogramming system for example Count down or Statistics 23 0 MENEG ELNEC s r o Software Detailed description of Graphics user in
25. e to read chapter Local administration Local administration For local administration of Stand Alone programmer you must have connected standard PS 2 keyboard PS 2 mouse and standard analog display with resolution 1024x768 and 32bit color supported Operating disk is divided to three volumes First volume named as Recovery C contains software for OS recovery of programmer to state as shipped from factory Standard start time of programmer is about 2 minutes When device doesn t start in 10 minutes then it may be necessary to perform OS recovery Before operating system recovery connect monitor to programmer and kindly report what you see to programmer manufacturer For next steps refer to Operating system recovery chapter Second volume is System D and contains Windows XP Embedded operating system Warning Do not delete change files or perform any writes on Recovery or System disk volumes Third volume is named as Data E This volume contains Programmer Projects Logs Updates and Temp directories Programmer is directory where main control software is installed In directory Logs are saved log files from operations with devices When OS update files are available they should be saved to Updates directory Your project files should be in Projects directory Exact update steps will be distributed with operating system updates For programmer reliability operating system is configured with write filte
26. eeccececsuseecsaeeessuseeseuseeseueesseeessueeeseuseesausessaesessaes 7 Manipulation with the programmed device a 8 In system serial programming by BeeHive2089S 8 Selftest and calibration check PME 10 Technical 5 u uu RE uuu T T T TT 12 Programming suu u u n aduana a 17 Engineering MOUS RETE TTE TET UT 17 Producton ModE PEE 21 clo U wae 24 Detailed description of Graphics user interface with touch screen 24 Adirni istra on of build uuu uuu 40 Troubleshooting and warranty U u u u u 44 TOUDE SHOO M uu u u LETTURE 44 If you have an unsupported target 45 VANS Chace EE OE 45 NATIT ITE Te PIS o E E ED BOR 46 Please download actual version of manual from ELNEC WEB site www elnec com if current one Will be out of date Conventions used in the manual References to the control program functions are
27. er AES ELNEC s r o 8 9 10 8 11 12 8 12 connectors e g for display keyboard mouse 13 power switch 14 power supply connector 15 Soft power ON OFF button Manipulation with the programmed device After the selection of desired device for your work you can insert it into the open ZIF socket lever is up and close socket lever is down The correct orientation of the device in ZIF socket is shown on the picture near the ZIF socket on the programmer cover The programmed device must be removed from the socket when the BUSY LED is off Note Programmer protection electronics protect the target device and the programmer itself against either short or long term power failures and partly against a PC failure However it is not possible to guarantee the integrity of the target device due to incorrect user selected programming parameters Target device may not be destroyed by forced interruption of the contro program turn off programmer but the content of programmed cells may remains undefined Don t unplug the target device from the ZIF socket during work with device BUSY LED on In system serial programming by BeeHive208S Optimized advanced pindrivers deliver programming performance without overshoot or ground bounce for all device technologies Pin drivers operate down to 1 8V so you ll be ready to program the full range of today s advanced low voltage devices The ISP programming solution
28. er ISP cable other material length programming may become unreliable e BeeHive208S can supply power to the programmed device pin 1 of ISP connector and the target system pin 19 and 20 of ISP connector with some limitations see Technical specification ISP connector e BeeHive208S applies programming voltage to target device and checks its value target system can modify programming voltage If the programming voltage is different from expected no action with target device will be executed Selftest and calibration check Warning Selftest and calibration check can be run in engineering mode only 10 ELNEC s r o This mode is available only when external display keyboard and mouse are connected to BeeHive208S If you feel that your programmer does not react according to your expectation please run the programmer ISP connector s selftest using Diagnostic POD Diagnostic POD for ISP connectors 2 enclosed in the standard delivery package Selftest of programmer e Insert 48 pin diagnostic POD type l into ZIF socket of the programmer Take care about orientation of 48 pin diagnostic POD type I see top side of POD e Run selftest of programmer in PG4uw Programmer Selftest plus Selftest of ISP connector e Insert Diagnostic POD for ISP connectors 2 into ZIF socket of the programmer Take care about orientation of Diagnostic POD for ISP connectors 2 e Interconnect the 20 pins connector of Diagnos
29. er switch placed at back side of programmer If programmer not starts cooling fans not start please push the Soft power ON OFF button on back side bellow banana jacks When the built in computer is turned on the operating system will start booting up cooling fans should start to work and Wait please screen should be displayed on graphical control unit Starting of the operating system can take some time normally this time is shorter than 1 minute After the operating system has successfully started the Pg4uwMC control program will start automatically When the Pg4uwMC is ready to work the Welcome screen is displayed on graphical control unit Click the OK button on Welcome screen to continue The main screen with menus and Status panel should appear on graphical control unit Checking if the sites are ready to be connected 7 When first starting Stand Alone multiprogramming system or when error message Programmer Sites not found is displayed then programmer software must be reinitialized by action Search for Programmers available in menu Programmer Search for Programmers In dialog Search for Programmers use button Search to search for present programmer sites The result of search will be displayed in table Search results in Search dialog When programmer sites are successfully found then programmer type and its serial number is show in the table Search result Detected programmer can be a
30. ers Buffer Device Programmer File Option s Help P Load Save Load prj Save prj Edit Log window 10 11 2009 09 40 12 Select site Select def Bj amp ami e m 0 4 Verify Program Select Blank Read crase Buffer checksum type set to Exclude buffer data for checks gt gt Log file created at 10 11 20 Log file name C Documents and Log file mode Append Addresses hex Org Device 8 Size 8888 Buffer x8 9 BeeHive2085 Site 1 BeeHive2085 Site 2 BeeHive2085 Site 3 BeeHive2085 Site 4 BeeHive2085 Site 5 BeeHive2085 Site 6 BeeHive2085 Site 7 BeeHive2085 Site 8 DataiElnec G File x8 Device CheckSum 007F8000h Serialization None Split None Atmel AT27C256 Note See also Device info lt Ctrl F1 gt Statistics Count down Disabled Remains 0 of 0 Reload Count down Port YES Automatic Filename Select desired BeeHive208S Site and then click on OK button AR ELNEC s r o P s 5b Select device click on icon and select desired device 6 Load data into buffer from file click on icon 7T Set Device operation options Device operation options Insertion Fest Insertion test Enable Device ID check Enable Command execution Erase before programming Disable
31. ers So there is a limited warranty of one year on all computer parts such as touch screen motherboard CPU HD If the product is diagnosed as defective ELNEC s r o or the authorized repair centre will repair or replace defective parts at no charge Parts used for replacement and or whole programmer are warranted only for the reminder of the original warranty period For repair within the warranty period the customer must prove the date of purchase 46 ELNEC s r o These warranty terms are valid for customers who purchase a programmer directly from Elnec The warranty conditions of Elnec sellers may differ depending on the target country law system or Elnec seller s warranty policy The warranty does not apply to products that are of wear and tear or mechanically damaged The warranty does not apply to any damage of programmer or its part caused by dust or dirt Equally the warranty does not apply to products opened and or repaired and or altered by personnel not authorized by ELNEC or to products that have been misused abused accidentally damaged or that were improperly installed For unwarrantable repairs you will be billed according to the costs of replacement materials service time and carriage ELNEC or its distributors will determine whether the defective product should be repaired or replaced and judge whether or not the warranty applies Manufacturer gt ELNEC s o Jana Bottu 5 SK 08001 Presov Slova
32. feature see documentation chapter Programmer Automatic YES Programmer Select Enabled Sites Command displays dialog Select Enabled Sites Select Enabled Sites Enabled Sites Site 1 Site 2 Site Site 4 Site 5 Site 6 Site 7 Site 8 This dialog is used to select sites that have to be used Each site is represented by one check box If the check box n is checked it means the site n is selected and device 32 SRE s r o operations will run it If the check box n is unchecked the site n is unselected so no device operations will run on the Site The sites can be set as selected or unselected anytime needed except during running device operation Menu Options File Device Programmer Help Settings Statistics View Log Protected mode ext serial value Sla Good 0 Total Ctdr Disabled Device Samsung KIGSE08U0M TSOP48 Project k398g08u m epr Checksum Options Settings Command displays dialog Settings with list of options user can choose from and set their properties and or settings gt Display settings gt TouchPad calibration gt Sounds Log file Log file settings screen looks as following Log file Log file settings e Rewrite Log file C3 Append Log file Log file name E ALogs reportmc lag C Add date information to Log file name Log file size limit
33. file will be preserved and new data will be appended to the existing Log file e option Rewrite Log file sets usage of Log file on Log file will be created after the first restart of Pg4uwMC For all other following executions of Pg4uwMC the existing Log file will be rewritten and new Log file will be created Data from previous Log file will be deleted e Checkbox Add date information to Log file name allows user to choose additional date information into Log file name When the checkbox is checked the program automatically adds current date string into Log file name through the following rules If log file name has format lt log_file_name gt lt log_file_extension gt The name with added date will be lt log file name yyyy mmm dd log file extension The new part representing the date consists of yyyy year mmm month and dd day Example Log file name is E Logs reportmc log The final log file name with added date will look like this July 7th 2007 E Logs reportmc 2007 jul 07 log Advanced options about Log file size limit e option Use Log file text truncating when file size limit is reached when checked the Log file size limit is on It means that when Log file size reaches specified value the part of text included in Log file will be truncated When the option is unchecked the size of Log file is unlimited respectively is limited by free disk space only e option Maximum Log file size specifies the max
34. h programmers which is used to reinitialize software configuration and to re find available programmer sites There is no need to use this menu command in normal operation Situations when the command is useful are 1 when first starting BeeHive208S Stand Alone multiprogramming system 2 when error message Programmer Sites not found is displayed In the dialog Search Programmers use button Search to search for attached programmers The result of search will be displayed in table Search results in Search dialog When programmer sites are successfully found the result shows the programmer type and allows you to accept new settings by button Accept Otherwise No Programmers found message will be displayed in table Search results and button Accept is disabled 30 ELNEC s r o If search result is No Programmers found please try to turn off Stand Alone programmer by menu File Shut down computer turn off the power button on the back side of programmer wait for 15 seconds or more and start programmer again If the search result is still No Programmers found please refer to troubleshooting documentation Programmer Connect Sites Menu command starts control applications for all available programmer sites The Connecting Sites indicator is displayed during connecting of sites Additional information about site connection progress is displayed for each site in the Status panel on the main
35. he completed form by e mail to your local dealer or to ELNEC nospam version elnec at elnec dot com Phone Copy DEVICE PROBLEM REPORT form and fill it in following the instructions at the end of the form Write everything down that you consider being relevant about the programmer software and the target device Send the completed form by mail or fax to ELNEC fax number in the control program menu Help About or to your local dealer If you send the form by fax please use black ink a good pen and large letters easily to read Then call your local dealer or ELNEC s customer support center phone number in the control program menu Help About Please keep your manual the programmer and the completed DEVICE PROBLEM REPORT form just faxed available so that you can respond quickly to our questions If your programmer is diagnosed as defective consult your local dealer or ELNEC about the pertinent repair center in your country Please carefully include the following items in the package defective product e completed DEVICE PROBLEM REPORT form e photocopy of a dated proof of purchase 44 SRE s r o Without all these items we cannot admit your programmer for repair Note You may find the DEVICE PROBLEM REPORT form at our Internet site www elnec com section Support Warning Class A ITE notice Devices described at this manual are class A products In domestic environment t
36. his products may cause radio interference in which case the user may be required to take adequate measures Because BeeHive208S have internal power supply follow these special precautions e Circuit breakers overcurrent protection must be a part of building electrical installation e Pull out power cord plug from outlet to disconnect programmer from mains If you have an unsupported target device If you need to operate on a target device not supported by the control program for programmer please do not despair and follow these next steps Look in the device list of the latest version of the control program on our Internet site section Download file corresponded to your programmer Your new target device might already be included in this version If yes download the file PG4uwARC exe and install the new version of the control program e Contact ELNEC direct filling up a Device Problem Report form following the instructions at the end of this form We may need detailed data sheets of your target device and if possible samples The samples will be returned to you after we include your target device in a new version of control software Note See also AlgOR service at our Internet site www elnec com section Support Maintenance We recommend following the instructions and precautions herein to achieve high reliability of the programmer for a long period of time The programmer maintenance depends on character and amount of
37. imum size of Log file in kBytes e option Amount of truncated text specifies the percentage of Log file text which will be truncated after Maximum Log file size is reached The higher value means more text will be truncated removed from Log file 34 SRE s r o Display settings L Use invert display mode Display settings dialog contains check box Use invert display mode When the checkbox is checked LCD screen will be displayed in inverted mode Otherwise it will be displayed in normal mode Touchpad calibration Command is used for calibration of built in touch pad part of built in LCD touch screen TouchPad calibration This will run touchpad calibration procedure where you can calibrate touchpad if you encounter not exact reactions fram touchpad Calibration procedure will show blank screen with point displayed User has to click on the point with included stylus There will be sequentially displayed few points at different positions Each of the point has to be clicked by user After clicking required number of points touchpad calibration iz complete which will be announced by message displayed Do vou wih to start touchpad calibration now The calibration of touchpad is recommended if you encounter unexpected reactions from touchpad If user confirms dialog about touchpad calibration with Yes button calibration procedure will start Calibration procedure will show blank sc
38. in bold e g Load File Device etc References to control keys are written in brackets lt gt e g F1 Terminology used in the manual Device any kind of programmable integrated circuits or programmable devices ZIF socket Zero Insertion Force socket used for insertion of target device Buffer part of memory or disk used for temporary data storage USB port type of PC port HEX data format format of data file which may be read with standard text viewers e g byte 5AH is stored as characters 5 and A which mean bytes 35H and 41H One line of this HEX file one record contains start address and data bytes All records are secured with checksum 3 ELNEC s r o Introduction BeeHive208S is extremely fast universal 8x 48 pindrive Stand Alone concurrent multiprogramming system designed for high volume production programming with minimal operator effort The chips are programmed at near theoretical maximum programming speed Block scheme of BeeHive208S external display Windows XP Embedded keyboard driven mouse high performance PC graphics control unit with touch screen optional lt 853 9 BeeHive208S consists of eight independent isolated universal programming modules based on the BeeProg2 programmer hardware Therefore BeeHive208S sockets can run asynchronously concurrent programming mode Each programming module starts programming at the moment the chip is detected to
39. ing systems Menu Device File Programmer Options Help Next serial value Statistics Good 0 Fail Disabled Device Samsung EKIGSG08U0M TSOP48 Project k388g908u m epr Checksum Device Predefined operation This menu allows user to select device Master operation Following Master operation are available Blank check Verify Program Erase 29 ELNEC s r o Each Master operation can consist of a sequence of one or more partial operations for example Program device operation can consist of the following sub operations 1 Erase 2 Program 3 Verify Selection of sub operations is stored in Project file For details about project file creation and usage refer to Engineering mode chapter Preselected device operation can be started by button Run operation name gt displayed on main screen Menu Programmer File Device Options Help Search for Programmers aen Connect Sites Disconnect Sites Automatic YES t serial val ext seria va select Enabled Sites Device Samsung KIGSE08U0M TSOP48 Project k388g908u m epr Checksum Programmer Search for programmers Search programmers Please select multiprogramming system from list bellow and click on button Search to start search for Programmers Multiprogramming system nx BeeHivegs Search results Programmer 1 Programmer found 1 BeeHiveBS s n Menu command displays the dialog Searc
40. it longer with one additional restart 43 ELNEC s r o Troubleshooting and warranty Troubleshooting We really want you to enjoy our product Nevertheless problems can occur In such cases please follow the instructions below It might be your mistake in not properly operating the programmer or its control program Please read carefully all the enclosed documentation again Probably you will find the answer right away e Ask your in house guru every office has one Askthe person who already installed the programmer If the problem persists please call the local dealer from whom you purchased the programmer or call ELNEC direct Most problems can be solved by phone e mail or fax If you want to contact us by Mail fax Copy the DEVICE PROBLEM REPORT form and fill it in following the instructions at the end of the form Write everything down that you consider being relevant about the programmer software and the target device Send the completed form by mail or fax to ELNEC fax number in the control program menu Help About or to your local dealer If you send the form by fax please use black ink a good pen and large letters E mail Use DEVICE PROBLEM REPORT form on the CD or from our Internet site and fill it in following the instructions at the end of the form Use standard ASCII editor Write everything down that you consider being relevant about the programmer software and the target device Send t
41. ite and serialization status Panel Next serial value Panel Statistics Recently selected device name Recent project name Checksum of data stored in data buffer for currently selected device Run button can be operation name for example Program Verify Erase Stop button Menu File Device Programmer Options Help Each menu item represents one menu command For detailed information about menu commands refer to menu commands description chapter Table with information about programmer sites site and serialization status Table contains key information about current status of programmer sites and serialization information for each Site If serialization is not used the Serialization column remains empty Sites that are not connected have displayed in the Status column Connected Sites have their Status displayed Following are typical values e Ready means the programmer site is connected and ready to start any operation e Present special status of connected Site means the site is connected but it is also not selected checked in dialog Select Sites User selected device or project operations will not run on unselected Sites User can set Site selection in dialog Select Sites accessible by menu command Programmer Select Enabled Sites e No project file is loaded means the Site is successfully connected but no project file is loaded It also means that no device is selected The recommended action is Load proje
42. its use Regardless the following recommendations are generally accepted e Do not use and store the programmer in dusty places e Humidity accelerates sedimentation of debris and dust in ZIF socket e After end the job cover the ZIF socket of the programmer with enclosed dust cover e Do not expose the programmer to direct sunlight or position near a source of heat 45 ELNEC s r o Daily maintenance Check the ZIF sockets of the programmer and the socket converters for their condition and wear Remove debris dust and grime from the ZIF sockets with clean dry and compressed air Clean the ZIF sockets both in closed and opened position Weekly maintenance Perform the Selftest plus for every programming module Quarterly maintenance Gently clean the surface of the programmer with isopropyl alcohol or technical alcohol on a soft cloth The LCD clean with a soft cloth moisten in water only Isopropyl alcohol may damage surface of the LCD Perform the calibration test using 48 Pins Calibration test POD Type l Biannual maintenance Check amount of dust or dirty in programmer If you feel that a lot of dust or dirty is in programmer clear it by vacuum cleaner The warranty does not apply to any damage of programmer or its part caused by dust or dirt Contact Elnec if you prefer to order this service by manufacturer Warning The ZIF socket of the programmer and the socket converters are considered as consumables The life cyc
43. ive price coupled with excellent hardware design for reliable programming It has probably best value for money programmer in this class BeeHive208S provides very fast programming due to high speed FPGA driven hardware and execution of time critical routines inside of the programmer At least programming speed is faster than competitors in this category for many chips it is much faster than most competitors As a result when used in production this programmer waits for an operator and not the other way round BeeHive208S provides the two banana jacks one for ESD wrist strap connection for easy to implement ESD protection and the second one for connection to ground FPGA based totally reconfigurable 48 powerful TTL pindrivers provide H L pull up pull down and read capability for each pin Advanced pindrivers incorporate high quality high speed circuitry to deliver signals without overshoot or ground bounce for all supported devices Pin drivers operate down to 1 8V so you ll be ready to program the full range of today s advanced low voltage devices BeeHive208S performs on each programming module device insertion test wrong or backward position and contact check poor contact pin to socket before it programs each device These capabilities supported by overcurrent protection and signature byte check help prevent chip damage due to operator error BeeHive208S has the selftest capability which allows the diagnostic part of software to
44. kia T 42151 77 34 328 77 31 007 fax 77 32 797 www elnec com e mail nospam version elnec at elnec dot com ELNEC has used its best efforts to develop hardware and software that is stable and reliable ELNEC does not guarantee that the hardware and software are free of bugs errors or defects ELNEC s liability is always limited to contract s net value paid by a buyer ELNEC is not liable for e Damage caused by inappropriate use or handling of products e Damage caused by users or third parties modifying or trying to modify products e Any further damage or consequent damage caused by hardware errors or software bugs e Damage caused by viruses root kits and so on For example ost profits lost savings damages arised from claims of third parties against a client damage or loss of recorded data or files renown loss caused by impossibility to use etc 47
45. laying in main window of control program in Statistics panel 36 ELNEC s r o Statistics panel contains three statistics values Good Fail Total two Count down information values Ctdn status and value Meaning of the values is Good number of operations which where successfully completed Fail number of operations which where not successfully completed Total number of all operations Ctdn informs about Count down activity En enabled or Disabled Remains informs about remaining number of device operations to do Notes When project file is loaded all statistics values are set to zero and Ctdn is set to Disabled For multiprogramming Pg4uwMC software the statistics information is also saved to Job Summary report Options View Log Log file X LOOOS Welcome to Elnec PaduwMc Multiprogramming Control Panel A 10006 Version 2 33 06 2007 10007 Today is 03 07 2007 06 03 45 10009 Processor Intel 6 15 6 Frequency 2400 2400 04 MHz 10010 Operating system Windows v5 1 Build 2600 Service Pack 10011 Physical RAM memory 1000 MB 10013 gt gt MC Log file created at 03 07 2007 06 03 46 10014 Log file name E Logs peportme log 10015 Log file mode New rewrite 0017 gt MC 03 07 2007 07 14 13 10018 Searching for connected programmers 10019 Programmers successfuly detected on USB 10020 Connecting Programmer Sites 0021 SITE 41 10022 07 14 31 Quick Selftest L0
46. le of the ZIF socket of the programmer is about 25 000 mechanical cycles The life cycle of ZIF sockets of the socket converters is in generally from 5 000 to 10 000 mechanical cycles even if the life cycle of some specialized BGA ZIF sockets can be about 500 000 mechanical cycles Programmed devices environment and ZIF maintenance have direct influence to actual electrical lifetime of ZIF socket it means that ZIF socket does not cause programming failures yet Keep fingers away from contacts of ZIF socket because contacts of the ZIF socket fouled by smear and grime from fingers may cause the programming failures Change the ZIF socket or the socket converter if you noticed increased number of programming failures The warranty does not apply to the ZIF sockets that are wear or grimy and which cause large amount of failures during working with programmer Warranty terms The manufacturer ELNEC s r o Presov Slovakia gives a guarantee on failure free operating of the BeeHive208S Stand Alone multiprogramming system including protective circuits original brand components and careful manufacturing and hours long burning in allows us to provide a three year warranty on parts and labor for the programmer limited 25 000 cycle warranty on ZIF sockets or 10 000 cycles on other ZIF sockets Although we take as much care as possible to integrate high quality components in the build in computer we can t provide higher warranty as we get from suppli
47. mmed or are they use data with only a few 0 bits FE EF etc ELNEC s r o This deceptive approach can decrease programming times considerably If you plan to compare ask always which pattern they use e The programming speed depends on the PC speed only slightly SOFTWARE e Algorithms only manufacturer approved or certified algorithms are used e Algorithm updates software updates are available regularly approx every 4 weeks free of charge Internet download OnDemand version of software is available for highly priority chip support and or bugs fixes Available nearly same day e Main features revision history session logging on line help device and algorithm information Device operations e standard intelligent device selection by device type manufacturer or fragment of part name e automatic ID based selection of EPROM Flash EPROM e blank check read verify e program e erase e configuration and security bit program e illegal bit test e checksum e interpret the Jam Standard Test and Programming Language STAPL JEDEC standard JESD 71 interpret the VME files compressed binary variation of SVF files e security e insertion test reverse insertion check e contact check e ID byte check e special e production mode automatic start immediately after device insertion e lots of serialization modes more types of incremental modes from file data custom generator mode e Statistics e count down mode
48. moments during installation Also restart of system will be performed automatically Press OF button to start installation Cancel During update process control program of Stand Alone programmer is closed LCD panel can be blank for some moments and after installation is complete automatic restart of standalone programmer will be performed Whole process should not exceed time of 1 2 minutes Help About Pg4uwMC z wer 2 54 11 2009 Universal stand alone multiprogramming system c 1992 2009 by ELNEE sro web http www elnec com Programmer type BeeHrvez2 085 Number of Sites available 8 Operating system Windows P v5 1 Build 2600 Service Pack 2 Processor Intel 6715 6 Frequency 2400 2400 06 MHz Physical RAM memory 1000 MB Computer name OEM USELHTPPFFA IP address 192 168 0 146 Date amp Time 11 3 2008 9 33 40 Welcome screen is displayed on standalone s build in LCD screen after successful starting of standalone control software The screen can be also displayed by using menu command Help About Welcome screen contains following basic information e version of control software 39 ELNEC s r o programmer type number of Sites available operating system information about processor and size of installed RAM memory computer name and IP address system date and time Welcome screen can be closed by clicking on button OK Administration of build in PC Introduction e Bee
49. one year on all computer parts such as touch screen motherboard CPU HD etc This warranty terms are valid for customers who purchase a programmer directly from Elnec company The warranty conditions of Elnec sellers may differ depending on the target country law system or Elnec seller s warranty policy Free additional services e free lifetime software update via Web site Free software updates are available from our Internet address www elnec com e Online technical support is available within promised 24 hours time limit or you may call us during business hours from Monday through Friday 8 30 to 17 30 CET e Keep Current is a service by which ELNEC ships to you the latest version of the control program for programmer and the updated user documentation A Keep Current service is your hassle free guarantee that you always have access to the latest software and documentation at minimal cost e AIgOR Algorithm On Request service allows you to receive from ELNEC software support for programming devices not yet available in the current device list SE EL NEC ELNEC s r o BeeHive208S elements 1 48 pin ZIF socket 2 work result LEDs 3 power sleep LED of site 4 YES Button 5 ISP connector 6 graphical control unit with touch screen 7 fan s grid 8 temperature controlled fans 9 banana jack for connection to ground 10 banana jack for ESD wrist straps connection 11 Windows XP Embedded serial number stick
50. performs programming verification at the marginal level of supply voltage which obviously improves programming yield and guarantees long data retention The ISP programming solution provides also the power supply for the target system This ISP programming solution provides very competitive price but excellent hardware design for reliable programming The software provides full information for ISP implementation Description of ISP connector pins for currently selected chip recommended target design around in circuit programmed chip and other relevant information SRE s r o For general definition recommendation and direction about ISP see section notes ISP please Description of ISP connector 2 4 6 8 10 12 14 16 18 20 B NH NH NH B NH NH NH NH B 1 3 5 7 9 11 13 15 17 19 E NH NH NH NH NH NH 8 NM B Front view at ISP connector H L read driver pins 3 5 7 9 11 13 of ISP connector pin 14 of ISP connector x A B i drivers in programmer ial i drivers in programmer Vec iic H L Float RB2 Read RB1 Pull up YES Pull down T GND pu re E 2 pins 15 16 of ISP connector D drivers in programmer CC1 pin of ISP pin of ISP connector connector n RD1 ri Float GND Read E pin of ISP CE1 connector wm RE1 RA1 180R RA2 1k3 RA3 22k RB1 10k R
51. project operation button and menu will be disabled when Protected mode is active If the option is enabled checked the Load project operation button and menu will be allowed in Protected mode To switch program from Protected mode back to Normal mode use the menu command Options Normal mode The Password required dialog appears User has to enter the same password as the password entered during switch to Protected mode When Protected mode is active the label Protected mode is visible near the top of Status table of main LCD screen Notes Sometimes when Protected mode is switched from active state to inactive state Normal mode some commands for example command Load project may remain disabled This can be resolved by clicking on button Stop When user forgot the password to turn off Protected mode then protected mode can be turned off by administrator by entering Administrator password Administrator login is not necessary Menu Help Help Index Menu command displays short help on built in touch screen The short help contains brief information about menu commands and basic operations with usage of touch screen Help Problem report Menu command Create problem report is used for writing more particular diagnostic information to Log window and consequently copy Log window content to problem report file Problem report is useful when an error occurs in the control program or programmer and that the user can not
52. reen with point displayed User has to click on the point with stylus There will be sequentially displayed few points at different positions Each of the point has to be clicked by user After clicking required number of points touchpad calibration is complete which will be announced by information message displayed Sounds Sound settings 6 M5 Windows sound C sound Use beep sound on touchscreen press 35 ELNEC s r o Dialog Sounds settings allows user to select the sound mode of program Program generates sounds after some activities e g activities on device programming verifying reading etc Program generates sound also when warning or error message is displayed User can now select sound from MS Windows system sound requires installed sound card PC speaker or No sound The check box Use beep sound on touch screen press allows to switch beep sound on or off When the checkbox is checked beep sound will be generated on each touch screen press that software detects Otherwise no beep sound will be generated Options Statistics Statistics Current statistic Apply statistics increment on Success 0 Device Program Failure 0 Device Verify Total 0 Device Blank check Device Erase Clear statistics Count dow L Enable Count down x E Command displays dialog Statistics Statistics gives the information about actual count of device operations which were proceeded on selec
53. resolve and he must contact programmer manufacturer In this case when customer send message to manufacturer about his problem it is good to send also problem report Problem report can help manufacturer to localize the reason of error and resolve it sooner Help Update software This important menu command allows users to make software updates After selecting this item program will display question Are you If user confirms the question with answer Yes dialog Select installation package will be displayed 38 SRE s r o Select installation package 1 files Directory e UobRepors a a Logs Frogrammer Projects Drive Data 71 170 MB of 74 551 MB free In this dialog user can browse for the pg4uwarc installation package he wishes to install The installation package can be copied before to shared Stand Alone folder via network or it can be stored on a USB key which can be plugged into USB port of Stand Alone programmer When USB key is plugged to USB port of programmer new drive letter assigned with USB key will appear in list of available drives in dialog Select installation package User can than select this drive and run installation package from the USB key When user confirms another confirmation dialog update process will start Pg uwtAC Install software System iz ready to install software Pgduwl C v2 38 amp The LCD can be blank for some
54. rs on Recovery and System disk As a side effect of these filters any configuration changes in entire operating system will be wasted after restart or shutdown programmer Operating system recovery Recovery OS performs refreshing of programmer operating system to state as it was shipped from factory Before operating system recovery connect monitor to programmer and kindly report what you see to programmer manufacturer To perform operating system recovery you must have connected keyboard mouse and display Turn on programmer After starting BIOS screen Windows show this screen Choose an operating system to start Use the arrow keys to highlight your choice then press ENTER Windows XP Embedded indows Recovery 42 ELNEC s r o With arrow keys up or down select Windows Recovery and press Enter Recovery system will be started Please be patient This can take about four minutes Then EULA license will show Please read carefully this license agreement close window press if you accept this agreement Accepting agreement starts formatting of disk D and installation of control program recovery deletes Programmer directory on disk E and creates new one Also directories Updates and Temp has been erased and recreated When recovery is completed you should see System recovery completed Then press any key and system will restart First start of the operating system after recovery may be a b
55. screen Programmer sites are numbered from 1 to 8 in direction of physical placing of sites from left to right When connection process of is complete indicator Connecting Sites will be hidden The Status panel will contain information about each site Following status information are most common e Ready means the programmer site is connected and ready to start any operation e Present special status of connected site means the site is connected but it is also not selected checked in dialog Select sites User selected device or project operations will not run on Present unselected sites User can set site selection in dialog Select sites accessible by menu command Programmer Select Enabled sites e No project file is loaded means the site is successfully connected but no project file is loaded It also means that no device is selected The recommended action is Load project e other text describes current status of site s Programmer Disconnect Sites Menu command is used to disconnect all programmer sites and close Programmer sites control applications The command will apply only if no device operation is currently running on any of connected sites The command does not close main control program Also Stand Alone programmer computer remains running Programmer Automatic YES Command displays dialog Site settings with Automatic YES options site settings Automatic YES Q e OFF C Use Project
56. services e Keep Current e AlgOR e free technical support phone fax e mail e free lifetime software update via Web site 16 ELNEC s r o Programming a device BeeHive208S can operate in two modes Engineering mode for creating a project Production mode for mass production Engineering mode Warning This mode is available only when external display keyboard and mouse are connected to BeeHive208S To switch to Engineering mode use File Switch to Engineering mode This part of the software is focused on the quick and easy preparation of the project file for use in the production mode of the control software Each programming module is driven by an easy to use control program with pull down menu hot keys and on line help Selecting of the device is performed by its class by manufacturer or simply by typing a fragment of vendor name and or part number It is the same time proven software as is used for all other Elnec single site programmers Engineers can use all properties of this software and can make a project for mass production Standard device related commands read blank check program verify erase are boosted by some test functions insertion test connection check signature byte check and some special functions autoincrement production mode start immediately after insertion of chip into socket All known data formats are supported Automatic file format detection and conversion are done during
57. ted type device If one device is corresponding to one device operation e g programming the number of device operations will be equal to the number of programmed devices Statistics dialog contains following options Check boxes Program Verify Blank and Erase which define operations after which statistics values increment Any selected and performed device operation will increment the Total counter and one of the Success or Failure counters depending on device operation result success or failure A combination of partial operations is counted as one operation only For example a Read operation including Verify after Read is one operation A Program operation including Erase and or Verify operations is counted as one operation The next function of statistics is Count down Count down allows checking of the number of device operations and then the number of devices on which device operations have to be done After each successful device operation the value of count down counter is decremented Count down has user defined start number for devices to do When count down value reach zero it means the specified number of devices is complete and a user message about complete count down will be displayed Check box Enable Count down sets Count down activity enable or disable Edit box following the Enable Count down check box defines initial number of count down counter from which count down starts Actual statistics values are disp
58. terface with touch screen Wait please screen ELNEC c5 2667 Ps4uuMC is startin wait Please Wait please screen is displayed on standalone s built in LCD screen as the first screen after turning on power The screen is shown during booting up of operating system and starting of standalone control software Pg4uwMC Welcome screen About screen 4 5 Pq4uwMC zi ver 2 64 11 2009 Universal stand alone multiprogramming system c 1992 2009 by ELNEE sro web http www elnec com Programmer type BeeHrve2085 Number of Sites available 8 Operating system Windows 54 v5 1 Build 2600 Service Pack 2 Processor Intel 6715 6 Frequency 2400 2400 06 MHz Physical RAM memory 1000 MB Computer name IP address 132 158 0 145 Date Time 11 3 2008 9 33 40 v OK Welcome screen is displayed on Stand Alone build in LCD screen after successful starting of standalone control software The screen can also be displayed by using menu command Help About more information see Help About Welcome screen can be closed by clicking on button OK 24 ELNEC s r o File Device Programmer Options Help Hext serial value Statistics Mone Total Ctdn Disabled Device Samsung ESIGSGOSUOM TSOP48 Project k9g8g08ulm epri Check DF0T9FS5h Main screen consists of following parts Menu File Device Programmer Options Help Table with information about programmer sites s
59. thoroughly check the health of the each programming module BeeHive208S has a built in protection circuit for eliminating the damage of programmer and or programmed device due to environment or operator failure All ZIF socket pins of BeeHive208S programmer are protected against ESD up to 15kV BeeHive208S performs programming verification at the marginal level of supply voltage which obviously improves programming yield and guarantees long data retention Various socket converters are available to handle devices in PLCC SOIC PSOP SSOP TSOP TSSOP TQFP QFN MLF SDIP BGA and other packages It is important to remember that in most cases new devices require only a software update because the BeeHive208S is based on the truly universal BeeProg2 programmer With our prompt service you can have new device added to the list of supported devices within hours See AIgOR Algorithm On Request service for details Advanced design of the BeeHive208S Stand Alone multiprogramming system including protective circuits original brand components and careful manufacturing and long burning in periods allows us to provide a three year warranty on parts and labor for the 5 ELNEC s r o programmer limited 25 000 cycle warranty on ZIF sockets Although we take as much care as possible to integrate high quality components in the build in computer we can t provide higher warranty as we get from suppliers So there is a limited warranty of
60. tic POD for ISP connectors 2 with the ISP connector of the programmer with the ISP cable included in delivery with the programmer package Be sure that the pins are interconnected properly i e 1 1 2 2 20 20 e Run selftest of ISP connector in PG4uw Programmer Selftest ISP connector Calibration test e Insert 48 Pins Calibration test POD Type I into ZIF socket of the programmer e Run calibration test of programmer in PG4uw Programmer Calibration test 11 ELNEC s r o Technical specification Specification BeeHive208S multiprogramming system e 8x universal programming module 8x 48 pin DIL ZIF sockets and 8x ISP connector e operation result LEDs LED power e line power input 100 240VAC 60W max e banana jack for ESD wrist straps connection e banana jack for connection to ground Specification PC system inside of programmer e Microsoft Windows XP Embedded operation system e PC Intel Core 2 Quad 2 66 GHz e 2 GB RAM e 320 GB HDD SPECIFICATION valid for each programming module HARDWARE Base unit DACs e USB 2 0 high speed compatible port up to 480 Mbit s transfer rate e on board intelligence powerful microprocessor and FPGA based state machine e three D A converters for VCCP VPP1 and VPP2 controllable rise and fall time e VCCP range 0 8V 1A e VPP1 VPP2 range 0 26V 1A e autocalibration selftest e Selftest capability Socket pindriver e 48 pin DIL ZIF Zero Insertion Forc