Home

PRESSURE TRANSMITTERS

image

Contents

1. Analytical Instruments and Systems PRESSURE 80 TRANSMITTERS f D2 AS be Stainless Steel Pressure Transmitters wi KAI N D gt Oo e 73 Pressure Transmitter with NEMA 4X Junction Box Features Model Selection Guide 4 20 mA output with internal test i Pressure Maximum Burst Catalog circuit connection f Range Pressure Pressure Number n Junction box cover unscrews for a Anoa M Ea g access to internal terminal block a ka gt ies gt i i p 2 z All stainless steel design meets NEMA 4X 0 10 PSI 72 PSI 87 PSI 12127507 S5 standard for washdown and corrosion ae i ae ie iv 2 oo 2 i 3 resistance IP67 Ingress protection 0 30 PSI 75 PSI Bail ioe a i 0 60 PSI 240 PSI 290 PSI 12127566 D WIKA s F 2X pressure transmitters are designed 0 100 PSI 240 PSI 290 PS 12128873 for use in difficult corrosive environments The 0 160 PSI 500 PSI 500 PSI 600 PSI 600 PSI 12127574 12127582 0 300 PSI 500 PSI 600 PSI 12127591 0 500 PSI 1160 PSI 5800 PSI 12127639 F 21 Flush Diaphragm Connection 0 50 WC 30 PSI 30 PSI 12126331 0 5 PSI 72 PSI 87 PSI 12127728 0 10 PSI 72 PSI 87 PSI 12127736 0 100 PSI 240 PSI 290 PSI 12127744 smooth surface reduces areas where contaminants may collect and makes it ideal for use in food and pharmaceutical industries 0 200 PSI The F 20 features an all welded stainless steel measuring cell for im proved media compatibility There are no
2. PROGRAMMING TOOLS 95 MC Toolkit Handheld Configurator e Configures any Honeywell DE device ST3000 pressure and STT3000 temperature transmitters and configures any HART device with a published HART Device Descriptions DD regardless of device manufacturer e Comes fully loaded with complete set of HART device descriptions Download new device descriptions from the HART website or get the latest DD releases from the manufacture s website e Intuitive user interface provides simple navigation with detailed explanations e Fully supports all HART 5 X commands and universal commands for HART 6 Uses DD IDE SDC 625 technology and Open Tools standard Specifications Pocket PC i roc 627 HP iPAQ hx2490 or equivalent with Intel PXA270 520 MHz processor 128 MB ROM and 64 MB SDRAM 1GB flash memory MS Windows Mobile 5 0 OS 3 5 TFT color touchscreen LED backlight Operating Conditions Temperature 14 to 122 F Humidity 10 to 90 rH Power Rechargeable Lithium lon battery AC power options accept 90 264 VAC inputs Memory Requirements Approx 51MB includes all HART registered DDs MC Toolkit software including SDC 625 and HART DD files are loaded on flash memory card Flash memory card in the MCT202 is not removable Approvals European EMC Standards EEC Directive 89 336 EMC CE Mark FM C US Intrinsically Safe Class Div 1 Group A D Non incendive Class Div 2 Group A D ATEX Intrinsically Saf
3. 379 25 379 25 379 25 379 25 379 25 0 10000 PSI 52376834 251 52375471 379 25 Attachable Loop Powered Indicator 7082534 295 74 Intrinsically Safe Hazardous Area Transmitters Features e FM CSA approved intrinsically safe for Class I Il and Ill Div 1 Groups A G dust class Il Ill Div 1 Groups E G Class I Zone 0 ATx ia II C e ATEX approvals for gases vapors and mists in Zone 0 1 and 2 For dust ap Par i g0 l VU D N 7a VU OW APPROVED Model Selection Guide Catalog Range Number IS 20 S Intrinsically Safe Transmitter N Zone 20 21 and 22 and mining categories M1 and M2 0 5 12127851 n O p 0 10 12127877 516 T e Suitable for SIL2 per IEC 61508 IEC 61511 0 15 PSI 12127885 516 03 p 2 e Rugged NEMA 6 stainless steel case all stainless wetted parts with all ae 2 S hie aa vE i T JIE welded measuring cell for improved media compatibility 6 20 6S o 516 03 B S e Accuracy to lt 0 25 span BFSL non linearity one year stability to lt 0 2 0 100 PSI 12127922 516 03 rian span non repeatability to lt 0 1 span 0 160 PSI 12127940 16 03 EE l i 0 200 PSI 12127966 516 03 For ambient and media temperatures of 4 to 176 F 0 1000 PSI 12128040 516 03 F e Call for flush diaphragm mount or models with integral junction boxes O OAU ieee 1 eee E e e e e N Pressure Transmitters for 3A Sanitary Applications sE e WIKA Type S 10 3A sanitary transmitters
4. II 1 G Ex ia IIC T4 Non Incendive II 3 G Ex nA IIC T4 Enclosure P66 IP67 SIL 2 3 Certification 1EC 61508 SIL 2 for non redun dant use and SIL 3 for redundant use according to EXIDA and TUV Nord Sys GAUGE PRESSURE 93 U i e Y Ho neywell Ordering Instructions T N Make one selection from each table section below Follow the availability column down and check NS any restriction letters or notes to be sure the unit is available A finished catalog number looks like this S Dimensions a EE E E w s i gt TARE AAA Model Selection Guide 2 46 2 49 2x0 57 a Catalog Avail erin Description Number TT AFTAN al Dual Head 5 to 500 PSI 0 35 to 35 bar STG740 1374 00 RE 30 to 3000 PSI 2 1 to 210 bar STG770 1456 00 In Line 5 to 500 PSI 0 35 to 35 bar STG74L 1250 00 w 30 to 3000 PSI 2 1 to 210 bar STG77L FL Meter Plated CS Head 316L SS Diaphragm 5 Body 316 SS Head 316L SS Diaphragm Fill Fluid Silicone Oil DC 200 n Fluorinated Oil CTFE S O Le Process 9 16 Aminco Connection 1 2 NPT Female Bolt Nut Carbon Steel Materials 316 SS Grade 660 NACE A286 NACE 304 SS Nuts Head Type Single Ended Vent Drain Single Ended Side Drain and Vent Position Single Ended Side Drain Center SS Vent Dual Ended End Drain and Vent Dual Ended End Drain Center SS Vent Dual Ended Gasket Teflon or PTFE Glass Filled Viton or Fluorocarbon Elastomer Graphite Hea
5. number includes transmitter and flange and looks like this 7MF4633 ZB11 with 7MF4812 Model Selection Guide Catalog Number 7MF4633 1677 22 Description 1 SITRANS P DS III Level Transmitter 10 to 100 H20 10 to 240 H20 20 to 640 H20 64 to 2000 H20 Pressure M20 x 1 5 Not Available with FM CSA 1 2 14 NPT Select with Approval 1N Hidden Digital Display Digital LCD Set to mA Digital LCD Set per Option Y21 Built in Indicator O Ring PTFE Teflon Approved for Food Sealing Screw 1 2 18 NPT with Vent Valve English Rating Plate Rating Plate Pressure Units in H20 to PSI ISO 8402 Test Calibration Certificate ISO 8402 Calibrated Measuring Range Please Specify Tag Number 16 Characters Maximum Measuring Point Description 27 Characters Max Set LCD Specify Units PSI InH2O FtH20 A40 B11 B21 C11 YO Y15 Y16 Y21 units 2 Mounting Flange for SITRANS P Level Transmitter 7MF4812 904 00 3 Class 150 3Q _ 84 00 4 Class 150 3T_ Call Material 316L Stainless Steel A Hastelloy C276 a a 232 00 ___01 11 Size No Tube Silicone System Fill DC200 10 2 Tube Silicone System Fill DC200 10 6 Tube Silicone System Fill DC200 10 Tube HART Handheld Communicator Fast startup long battery life on standard batteries Holds hundreds of de vice files and configurations Download new DOF and firmware updates from www Meriam co
6. steel 2300 psi stainles steel and Elgiloy Case Stainless steel Internal transmission fluid Synthetic oil only for pressure E 10 Series With 6 Ft Cable With 6 Ft Leads 3 D ranges up to 300 psi or flush diaphragm units 4 20 mA Pressure Samar price Namir erie y Power supply Us 10 to 30 VDC Transmitter Range Number Number 2 5 Response time 10 to 90 lt 1 lt 10 ms for media temperatures lt 22 F 0 O NIVAE 22131723 2430 47 On o 0 15 PSI 50989333 482 01 5 30 C for pressure ranges up to 300 psi or with flush diaphragm 0 60 PSI 4363082 417 72 50989341 482 01 2 Accuracy lt 0 25 BFSL of span lt 0 5 limit point calibration span 1 4 NPT 0 100 PSI 4363090 417 72 4363189 482 01 K a Stability lt 0 2 at reference conditions span one year Male 0 200 PSI 4364844 417 72 50139061 482 01 SWa sKs pue SJUaWUNAYSU Je21 jeuy Temperature limits Ambient 22 to 212 F 30 to 100 C Approval FM CSA explosion proof Class Div 1 Groups A D Dust ignition proof Class II IIl Div 1 Groups E G FM Standards according to class number 3600 3615 and 3810 Ingress protection NEMA 4X IP 67 Process Connection 1 2 NPT Male Process Connection 0 300 PSI 0 500 PSI 0 1000 PSI 0 3000 PSI 0 5000 PSI 30 0 HgVac 0 15 PSI 0 60 PSI 0 100 PSI 0 200 PSI 0 300 PSI 0 500 PSI 0 1000 PSI 0 3000 PSI 0 5000 PSI 4363103 4363111 4363129 4202506 4363155 437113
7. IEC 801 Loop Powered Digital Indicator 0 4 high LCD programmable display range 1999 to 9999 e Accuracy 0 2 span e Scaling points are individually adjustable using push buttons inside the case 4 20 mA output can be assigned any value within measuring range e ABS plastic case polycarbonate window PRESSURE TRANSMITTERS 7 E ap 7 2 e e 2ce WIKA Industrial Pressure Transmitters ae e e e e a High Performance Pressure Transmitters for General Service Applications VU l Features Model Selection Guide e All stainless steel construction 0 5 Non Linearity 0 25 Non Linearity e Measuring ranges from 0 10 PSI to UE l A alabildi v 0 20 000 PSI plus compound ranges S 20 General Service Transmitter u gt 30 HgVac 0 PSI 52377199 322 88 52375595 451 00 3 Non linearity up to 0 125 BFSL 0 10 PSI 52377563 251 13 52376460 379 25 5 0 60 PSI 52376567 251 52375293 379 25 lt DIN remote cable and M12 connections 0 100 PSI 52374319 251 52374301 379 25 LL e Service life rated to 100 million load cycles For use in ambient temperatures to 257 F media temperatures to 392 F 0 200 PSI 0 300 PSI 0 500 PSI 0 1000 PSI 0 3000 PSI 0 5000 PSI 52376591 52376613 52376648 52376672 52376770 52376800 251 251 251 251 251 251 52375323 52375340 52375366 52375391 52375421 52375455 379 25
8. Range Transmitter 0 100 PSI 0 250 PSI 0 500 PSI 0 1000 PSI 0 2000 PSI 0 2500 PSI 0 3000 PSI 0 5000 PSI 4 20 mA 1 5 VDC Was Option M204 0 10 VDC T D P Call for Autoclave pressure connection and other options 0 00 0 00 0 00 Level Measurement Instruments Flow Measurement Instruments _ ep 7a 49 ep 7a 7a ep pau ae Temperature Sensors and Transmitters Communications Wireless Sensing and Analytical Instruments and Systems SJUSWNJSU jUaWaINseayl 2427 sJUdUUNI SU jUaWaINSea MO 0 5 D wa V D g V t D s1 IUSULI pue SIOSUSS Inzes dw SUOI eEDIUNWIWO gt pue Bulsuas ssajadi SWa sKs pue SJUaWUNAYSU edIA EUY 82 PRESSURE TRANSMITTERS Tired of the need for a HART communicator every time you want to do something on a transmitter a Has a tech ever gone out into the field and been unable to do anything because he forgot his handheld or had the wrong one b How many HART communicators do you have What happens when you want to configure or reconfigure a transmitter and a HART communicator isn t readily available c Wouldn t it be nice if you could configure a transmitter or change the configuration without carrying a HART communicator Thecost ofanewHARThandheldis 5 000 to 7 000 Siemens has Simatic PDM software 495 that does everything a handheld does including allow you t
9. SIL 2 3 Certification IEC 61508 SIL 2 for non redundant use and SIL 3 for redundant use according to EXIDA and TUV Nord Sys PRESSURE 89 TRANSMITTERS U z 2 Ho neywell Ordering Instructions gt Make a selection from each table section below Check any restriction letters or notes to be sure the unit is available A finished catalog number looks like this STD8__ ____ _ _ ___ ___ _ ____ __ 0000 T gt S Model Selection Guide Catalog Avail Description Number Tn Model 10 to 10 H20 0 1 to 10 H20 STD810 2019 00 Range Limits 400 to 400 H20 1 0 to 400 H20 STD820 1954 00 amp Span 100 to 100 PSI 1 to 100 PSI STD830 2061 00 100 to 3000 PSI 30 to 3000 PSI STD870 2121 00 w Meter Body Plated CS Head 316L SS Diaphragm 7 316 SS Head 316L SS Diaphragm A Displays provide PV Fill Fluid Silicone Oil DC 200 bargraphs trend lines Fluorinated Oil CTFE z and text messages Process None i for diagnostics and A l maintenance Connection 1 2 NPT Female Bolt Nut Carbon Steel Materials 316 SS Grade 660 NACE A286 NACE 304 SS Nuts r Head Type Single Ended Dimensions Vent Drain Single Ended Side Drain and Vent Position Single Ended Side Drain Center SS Vent Dual Ended End Drain and Vent Dual Ended End Drain Center SS Vent Dual Ended Gasket Teflon or PTFE Glass Filled Viton or Fluorocarbon Elastomer Graphite Head High Side Left Low S
10. Z A02 Z B21 Z M42 81 Need a different range Hastelloy diaphragm Larger ASME flange or TriClamp Call for pricing Stainless Steel Pressure Transmitter for Hazardous Areas Features e 0 25 accuracy e 5 1 turndown sure welded stainless steel wetted materials Zone 1 Dust Zone 21 reliability and durability and adjustability isn t required e Compact 316 stainless steel hermetically sealed enclo e UL approved explosion proof for hazardous locations Class l Div 1 Groups A D Class Il Div 1 Groups E G Class Ill ATEX certified for Equipment Category 2 Gas Enclosure United Electric s TX200 is a rugged pressure transmitter that s ideal for petrochemical applications All welded stainless steel construction provides airtight and watertight protection in the harshest environments A bonded foil strain gage sensor provides TX200A is field adjustable for zero and span using external 316 stainless steel control buttons It doesn t require a calibrated Outputs pressure source and can be calibrated in place TX200B is a cost effective solution for applications where the process is consistent Ordering Instructions Make one choice from each table section below A finished catalog number looks like this TX200 A 09 S 1 Designation Model Selection Guide Catalog Description Number Hazardous Area Transmitter 1 4 NPTF Conn 0 00 600 00 300 00 Field Adjustable Transmitter Fixed
11. field device manufacturers ean oe arse S L Description Number OQ Device Integration SIMATIC PDM v8 1 Software for Configuration Commissioning and ns SIMATIC PDM is the most efficient process device manager on the Diagnostics of Intelligent Field Devices Supports Profibus and HART world market With SIMATIC PDM you can assign parameters to more SIMATIC PDM with 1 Tag TGX PDM 3HA18 0YA5 77 00 than 1 000 different field devices by over 150 manufactures worldwide SIMATIC PDM with 4 Tags TGX PDM 3AB18 0YA5 689 00 and new field devices are constantly being added to the list 10 Additional SIMATIC PDM Tags TGX PDM 3XC18 2YB5 157 00 The electronic device descriptions EDD are either onthe supplied CD 100 Additional SIMATIC PDM Tags TGX PDM 3XD18 2YB5 1454 00 of SIMATIC PDM or can be obtained from the field device manufacturer on a diskette or via the Internet Using import functions you can eas ily integrate new field device descriptions or corrections into SIMATIC PDM anytime Connection Devices User Interface Catalog The SIMATIC PDM user interface offers menu structures and toolbars Description Number as well as an Explorer view that makes navigation between parameter HART Siemens RS 232 Hart Modem SME4997 1DA 5449 65 groups easier You can easily navigate in highly complex stations such Modems Siemens USB Hart Modem 7MF4997 1DB 591 10 as Remote I Os up to connected field devices i SWa sKs pue SJUBWUNAYSU Je21
12. highest level of compatibility assurance and integration capabilities The ST800 modular features a basic alphanumeric LCD display that can be added or removed in the field For easier access and visibility the display can be mounted and adjusted to 0 90 180 and 270 degree posi tions The two line 16 character LCD can display any one of 16 standard engineering units plus square root output indication Suitable for all electrical and environmental requirements SmartLine offers the ability to zero and span the transmitter from three externally accessible buttons With the display option these buttons also let you configure the transmitter and display Using a handheld Honeywell MCT202 configurator and Smartline transmitter two way communications you can field configure DE and HART devices If you prefer you can use Honeywell s SCT3000 configu ration toolkit and a PC to configure Honeywell Digitally Enhanced DE instruments Field Device Manager FDM software and FDM Express are available for managing HART and Fieldbus device configurations ST800 transmitters integrate with Honeywell s Experion PKS control software platform for tamper reporting FDM plant area views and health summaries To help control maintenance and inventory costs Honeywell ST800 transmitters are modular giving you the ability to replace meter bodies add indicators or change electronics modules without affecting overall per formance or approval certifica
13. meet 3A stan Model Selection Guide a e dards for pressure and level measurement A 316 stainless Me steel flush diaphragm minimizes product buildup The food 1 5 Tri clamp 2 Tri Clamp ne grade liquid filled sealed sensing system is designed for Description Catalog Price Catalog Price Ge Clean In Place and Sterilize In Place maintenance a 0 15 PSI 9748202 755 22 9748210 755 22 S 10 3A transmitters are temperature compensated to ensure long term stability under extreme temperature changes The gel potted circuit board is protected against vibration shock and moisture Condensed Specifications Accuracy 0 5 span Hysteresis 0 1 span Repeatability 0 05 span One Year Stability 0 2 span Zero Span Adjustment Approx 0 5 full scale Temperature Compensated 32 to 175 F Media 14 to 248 F Ambient 14 to 175 F Temperature Error Percent of span per 18 F Construction Body 304SS Diaphragm 316SS Connection DIN 43560 solderless screw terminal 316SS IP65 NEMA 5 Transmitting Liquid Vegetable oil Pressure Range 0 30 PSI 0 60 PSI 0 100 PSI 0 160 PSI 0 200 PSI 0 250 PSI 0 500 PSI 0 1000 PSI 9748075 9744703 9748237 9748245 9749408 9776227 50961667 8993470 755 22 755 22 755 22 755 22 755 22 755 22 755 22 755 22 4225007 9748199 9747931 9748253 4213246 4268831 9745828 4281737 755 22 755 22 755 22 755 22 755 22 755 22 755 22 755 22
14. pointers from min max values for input pressure sensor temperature and electronic temperature The record provides information on the status of the transmitter on the process and on the ambient temperature Simulation functions Enabling the transmitter electronics and the entire loop to be checked directly after the sensor e g for system startup This provides important information on whetherthetransmit ter electronics are in proper order at what pressure the limits respond and whether the controller loop is working properly and all displays are functioning e Easy exchange of defective parts If the device signals an error in the electronics or measuring cell no recalibration is required Just a matter of adjustment a high contrast LCD are all you need to set parameters on site and they ll yield the high level of accuracy you desire Leave the screwdriver in your toolbox Three pushbuttons and re You can set minimum and maximum measurement range adjust the damping of the output and the failsafe direction high or low all without having to open the cover on the transmitter maintaining the hazardous area rating You can also change from linear to square root or adjust the measurement range up to a ratio of 100 1 at the push of a button Electronic damping of up to 100 seconds can be selected as are up to 17 different pressure engineering units And if you re looking for the most convenient way to
15. 0 to 257 F LCD 4 to 158 F Humidity 0 to 100 RH Vacuum Region Pressure 1 WC min absolute 2 hours at 158 F Maximum Allowable Working Pressure MAWP 4500 PSI for tempera tures 40 to 257 F Static Pressure Limit is derated to 3000 PSI for 15 to 40 F for all models Use of graphite o rings derates transmitter to 3625 PSI Use of 1 2 process adaptors with graphite o rings derates transmit ter to 3000 PSI Analog Output Two wire 4 to 20 mA HART amp DE Transmitters only Digital Communications Honeywell DE HART 7 protocol or FOUNDATION Fieldbus ITK 6 0 1 compliant Output Failure Normal Limits 3 8 to 20 8 mA Honeywell standard or 3 8 to 20 5 mA NAMUR NE 43 Compliant Failure Mode lt 3 6 mA and 221 0 mA Supply Voltage 10 8 to 42 4 VDC at terminals IS versions limited to 30 VDC Voltage Effect 0 005 span per volt Transmitter Turn On Time HART or DE 2 5 seconds Foundation Fieldbus Host dependent Includes power up and test algorithms Response Time Delay Time Constant HART or DE 90 mS Foundation Fieldbus 150 mS host dependent Damping Time Constant HART Adjustable from 0 to 32 seconds in 0 1 increments Default 0 50 seconds DE Discrete values 0 0 16 0 32 0 48 1 2 4 8 16 32 seconds Default 0 48 seconds Vibration Effect Less than 0 1 URL without damping Per IEC60770 1 field or pipeline high vibration level Electromagnetic Compatibility IEC 61326 3 1 Lightning
16. 0 4365034 4365042 4365050 4369633 4365068 4365076 4365085 4365106 4365115 417 72 417 72 417 72 417 72 417 72 4363197 4363200 4363218 4363244 4363252 4365157 4365166 4365174 50033948 4365182 4365190 4365204 4365220 4365238 482 01 482 01 482 01 482 01 482 01 i 3 rhe eer ATENI Fa pope j i I J i Fi Tim Features e Reliable under extreme chemical and mechanical loads e High measuring accuracy with minimum conformity error and small long term drift lt 0 25 over 5 years e Programmable with local control keys and LCD display or by HART communication tools e Diagnosis and simulation functions Specifications Accuracy Linear characteristic curve span ratio lt 10 Gage pressure lt 0 0029 span ratio 0 071 Absolute pressure lt 0 1 Span ratio between 10 and 30 Gage pressure lt 0 0045 span ratio 0 071 Absolute pressure lt 0 2 Span ratio between 30 and 100 Gage pressure lt 0 005 span ratio 0 05 Temperature for measuring cell with silicone oil Ambient Temperature 40 to 185 F Digital display 22 to 185 F Process Media 40 to 212 F Wetted Materials 316L stainless steel or Hastelloy C Measuring cell filling Silicone oil or inert filling liquid Degree of Protection to EN 60529 IP65 IP68 NEMA X enclosure cleaning resistant to lyes steam to 302 F 150 C Electromagnetic Compatibility Emitted interference and noise immunity to EN
17. 0 transmitters integrate with Honeywell s Experion PKS control software platform for tamper reporting FDM plant area views and health summaries To help control maintenance and inventory costs Honeywell ST700 transmitters are modular giving you the ability to replace meter bodies add indicators or change electronics modules without affecting overall performance or approval certification Each meter body is uniquely char acterized to provide in tolerance performance over a range of varying temperatures and pressures Due to the Honeywell advanced interface electronic modules may be swapped with any electronics module without losing in tolerance performance characteristics Speed of response Stability 0 02 URL year for 5 yrs 0 01 URL per year Specifications Reference Accuracy 0 05 span Stability YURL year for five years STD720 0 020 STD730 0 040 STD770 0 030 Temperature Ambient 40 to 185 F Meter Body 40 to 257 F LCD 4 to 158 F Humidity 0 to 100 RH Vacuum Region Pressure 1 WC min absolute 2 hours at 158 F Maximum Allowable Working Pressure MAWP 4500 PSI for tempera tures 40 to 257 F Static Pressure Limit derated to 3000 PSI for 15 to 40 F Using graphite o rings derates transmitter to 3625 PSI Using 1 2 process adaptors and graphite o rings derates transmitter to 3000 PSI Analog Output Two wire 4 to 20 mA HART amp DE Transmitters only Output Fail
18. 1 C11 YO Y15 Y16 Y21 units Approvals Conduit Built in Indicator Transmitter with Carbon Steel Mounting Bracket Transmitter with Stainless Steel Mounting Bracket Rating Plate Pressure Units in H2O Respective to PSI Manufacturer s Test Calibration Certificate ISO 8402 Calibrated Measuring Range Please Specify Tag Number 16 Characters Maximum Measuring Point Description 27 Characters Max Set LCD Specify Units PSI InH2O FtH2O DIFFERENTIAL PRESSURE 85 Load Without HART Rg UH 10 5 V 0 023 A in Q UH power supply in V With HART Rg 230 to 500Q modem 230 to 1100Q communicator Communication Cable 2 wire 3 0 km Multi core 1 5 km PC Laptop Requirements IBM compatible RAM gt 32 MB file space gt 70 MB RS232 interface VGA graphics Windows OS and SIMATIC PDM lt gt APPROVED FM Approval Intrinsic safety and explosion proof 3008490 3610 3615 Explosion proof Class Div 1 Groups A D Dust ignition proof Class ll Div 1 Groups E G indoor and outdoor NEMA 4X hazardous classified locations ntrinsically safe With entity for use in Class I Div 1 Group A G indoor and outdoor NEMA 4X hazardous classified locations CSA Approval No 1153651 LR104225 Class 2258 02 Class 2258 03 CENELEC DIN EN 50 014 1997 EN 50 020 1994 and EN 50 284 1999 Level Transmitters Ordering Instructions Select one option from each table section below A complete catalog
19. 26 char line Conduit None Plugs 1 2 NPTM to 3 4 NPTF 316 SS Conduit Adapter Adapters 1 2 NPT 316 SS Certified Conduit Plug Minifast 4 Pin 1 2 NPT not for X Proof use Certificates Calibration Test amp Cert of Conformance F3399 Certificate of Origin FO195 FMEDA SIL 2 3 Certification FC33337 Documen Printed English User Manual 34 ST 25 44 Restrictions tation HART DE Communications Manual 34 ST 25 47 Safety Manual 34 ST 25 37 4 96 WY DISPLAY 2 45 OPTIONAL UISPLAY gt i LU j Available only with HART digital output Requires write protection enabled Function Block Manual 34 ST 25 49 Level Measurement Instruments Instruments Flow Measurement Pressure Transmitter Temperature Sensors and Transmitters Communications Wireless Sensing and Analytical Instruments and Systems SJUSWINJSU JUaWaINseayy 2427 SJUSWINAISU jUaWaINseayy MO o D wa 7 D g N at D s1 IUSULI pue s4osu JINJeJodWwa SUOI EDIUNWUWO gt pue Bulsuas Ssajadi SWa sKs pue SJUaWNAYsU Je217 jeuy PRESSURE 88 TRANSMITTERS STD800 SmartLine Differential Pressure Transmitter Features D e Accuracies to 0 0375 of span Ap e Stability up to 0 01 URL per year for ten years e Automatic static pressure amp tem perature compensation e Maximum turndown ratio to 400 1 e Response times as fast as
20. 61326 and NAMUR NE 21 Power Supply 10 5 42 VDC terminal voltage on transmitter 10 5 30 VDC for intrinsically safe operation Certificate and Approvals Intrinsic Safety to PTB 05 ATEX 2048 Ex Il 1 2 G EEx ia ib IIB IIC T4 T5 T6 PRESSURE TRANSMITTERS _SITRANS P300 All Stainless Pressure Transmitters SIEMENS Ordering Instructions Make one choice from each section below Follow the availability column down to be sure the unit you need is available A finished catalog number looks like this 7MF8023 1DB24 1AB6 ZA02 Model Selection Guide Description Catalog Avail Number ability P300 for Gage Absolute Pressure Threaded Conn 7MF8023 J 893 55 P300 for Gage Absolute Pressure Flanged Conn 7MF8123 893 55 Fill Silicone Oil Fill Standard Cleaning 0 14 5 PSIG 0 58 PSIG 0 232 PSIG 0 914 PSIG 0 72 5 PSIA Wetted Stainless Steel Seal Diaphragm and Cell Parts Diaphragm Seal Add 141 Process Conn Ca 1 2 14 NPT Select with Y above Ca Flange Version Add a Z _ Option 14 74 i 1M Approval None Rating ATEX Intrinsic Safety EEx ia FM CSA Intrinsic Safety 1 2 14 NPT Stainless Steel Display No Display With Keys Closed Lid Display and Keys Closed Lid Display and Keys Lid Plastic Pane 4 20 mA Display Keys Lid Glass Pane Specified Display Keys Lid Glass Pane Options Stainless Steel A2 70 Mounting Bracket Pressure Rating Plate English ASME Class 150 2 Flange
21. 7 jeuy
22. 90ms Alphanumeric display can be added or removed in the field e External zero span and configura tion capability e On board diagnostic capabilities e World class overpressure protection e Polarity insensitive electrical connections e Integral dual seal design for highest safety based on ANSI NFPA 70 202 and ANSI ISA 12 27 0 Replaces Retired e Compliant to SIL 2 3 requirements STD110 STD120 Honeywell DE HART v7 0 and Foundation bet Fieldbus communications options Honeywell s new SmartLine STD800 differential pressure transmitters feature piezoresistive sensor technology combining pressure sensing with on chip temperature compensation for high accuracy stability and performance overa wide range of application pressures and temperatures The SmartLine family is also fully tested and compliant with Experion PKS automation and control software platform providing the highest level of compatibility assurance and integration capabilities The ST800 modular features a basic alphanumeric LCD display that can be added or removed in the field For easier access and visibility the display can be mounted and adjusted to 0 90 180 and 270 degree posi tions The two line 16 character LCD can display any one of 16 standard engineering units plus square root output indication Suitable for all electrical and environmental requirements SmartLine offers the ability to zero and span the transmitter from three externally
23. PRESSURE TRANSMITTERS contents 77 ap ia 1 gt i gt ie cu Prices See Z 5 Startat Page a E o gt o Absolute Pressure SS Siemens SITRANS P300 Sanitary Pressure Transmitters 893 55 81 LL Honeywell STA800 SmartLine Absolute Pressure Smart Transmitters 2363 00 90 Differential Pressure 5 Honeywell STD700 SmartLine Differential Pressure Smart Transmitters 1384 00 86 i Honeywell STD800 SmartLine Differential Pressure Smart Transmitters 1954 00 88 Honeywell i 2 Siemens SITRANS P DS III Differential Pressure Transmitter 1589 19 84 i ra 7 Z n o V Gauge Pressure 2 Honeywell STG700 SmartLine Gauge Pressure Smart Transmitters 1250 00 92 Siemens SITRANS P DS IIl Gauge Pressure Transmitter 1174 38 82 UE TX200 Stainless Steel Pressure Transmitter for Harsh Environments 300 00 81 WIKA A 10 Stainless Steel Pressure Transmitters for OEM Service 156 73 78 s WIKA C 10 Pressure Transmitter for OEM Service 275 71 78 a T WIKA F 20 Stainless Steel Transmitter with Integral Junction Box 586 68 80 ne WIKA IS 20 Intrinsically Safe Gauge Pressure Transmitter 516 03 79 3 z WIKA S 20 General Service Gauge Pressure Transmitters 251 13 79 SE Q O e B Sanitary Pressure Transmitters WIKA S10 3A Gauge Pressure Sanitary Transmitters 755 22 80 Siemens SITRANS P300 Sanitary Pressure Transmitters 893 55 81 2a Accessories xs Honeywell SCT3000 SmartLine Configuration Toolkit 3237 00 95 5 t Honeywell MC Toolkit Pock
24. Protection Option Leakage Current 10uA max 42 4 VDC 93C Materials Barrier Diaphragms 316L SS Hastelloy C 276 Monel 400 Tanta lum Process Head 316 SS Carbon Steel Zinc plated Hastelloy C 276 Vent DrainValves andPlugs 316SS Hastelloy C 276 Head Gaskets Glass filled PTFE standard Viton graphite optional Meter Body Bolting Zinc Plated Carbon Steel standard 316 SS NACE A286 SS bolts Monel K500 Super Duplex and B7M optional Mounting Bracket 2 Pipe Carbon Steel Zinc plated or 304 Stainless Steel Fill Fluid Silicone DC 200 oil or CTFE Electronic Housing Pure polyester powder coated low copper aluminum Meets NEMA 4X P66 IP67 All stainless steel housing is optional Mounting Can be mountedin virtually any position using a standard mount ing bracket Bracket is designed to mount on 2 vertical or horizontal pipe Process Connections 1 4 NPT or 1 2 NPT with DIN adapter Wiring Accepts up to 16 AWG 1 5 mm diameter Enclosure Type 4X IP66 IP67 Communication Diagnostics HART 7 Foundation I Fieldbus Honeywell DE na e a AT tit Agency Approvals FM CSA Explosion Proof Class Div 1 Groups A D Dust Ignition Proof Class Il III Div 1 Groups E G T4 Intrinsically Safe Class II Ill Div 1 Groups A G T4 Non Incendive Class Div 2 Groups A D ATEX Flameproof Il 1 2 G Ex d IIC T4 Intrinsically Safe II 1 G Ex ia IIC T4 Non Incendive II 3 G Ex nA IIC T4 Enclosure P66 IP67
25. Vibration Effect Less than 0 1 URL without damping Per IEC60770 1 field or pipeline high vibration level Electromagnetic Compatibility IEC 61326 3 1 Lightning Protection Option Leakage Current 10uA max 42 4 VDC 93C Materials Barrier Diaphragms 316L SS Hastelloy C 276 Monel 400 Tanta lum Process Head 316 SS Carbon Steel Zinc plated Hastelloy C 276 Vent Drain Valves and Plugs 316 SS Hastelloy C 276 Head Gaskets Glass filled PTFE standard Viton graphite optional Meter Body Bolting Zinc Plated Carbon Steel standard 316SS NACE A286SS bolts Mounting Bracket 2 Pipe Carbon Steel Zinc plated or 304 Stainless Steel Fill Fluid Silicone DC 200 oil or CTFE Electronic Housing Pure polyester powder coated low copper aluminum Meets NEMA 4X P66 IP67 All stainless steel housing is optional Mounting Can be mounted in virtually any position using a standard mount ing bracket Bracket is designed to mount on 2 vertical or horizontal pipe Process Connections 1 2 NPT with DIN adapter Wiring Accepts up to 16 AWG 1 5 mm diameter Enclosure Type 4X IP66 IP67 Communication Diagnostics HART 7 Foundation tid Commas ANom PERTO pont L Fieldbus Honeywell DE TUY Y Agency Approvals FM CSA Explosion Proof Class Div 1 Groups A D Dust Ignition Proof Class Il III Div 1 Groups E G T4 Intrinsically Safe Class II Ill Div 1 Groups A G T4 Non Incendive Class Div 2 Groups A D ATEX Flame
26. accessible buttons With the display option these buttons also let you configure the transmitter and display Using a handheld Honeywell MCT202 configurator and Smartline transmitter two way communications you can field configure DE and HART devices Or if you prefer you can use Honeywell s SCT3000 con figuration toolkit and a PC to configure Honeywell Digitally Enhanced DE instruments Field Device Manager FDM software and FDM Express are available for managing HART and Fieldbus device configurations ST800 transmitters integrate with Honeywell s Experion PKS control software platform for tamper reporting FDM plant area views and health summaries To help control maintenance and inventory costs Honeywell ST800 transmitters are modular giving you the ability to replace meter bodies add indicators or change electronics modules without affecting overall performance or approval certification Each meter body is uniquely char acterized to provide in tolerance performance over a range of varying temperatures and pressures Due to the Honeywell advanced interface electronic modules may be swapped with any electronics module without losing in tolerance performance characteristics Specifications Reference Accuracy 7D810 0 0750 span STD820 0 0375 span STD830 870 0 05 span Stability YURL year for ten years S7D820 0 010 STD830 0 040 STD870 0 030 Temperature Ambient 40 to 185 F Meter Body 4
27. aded to the new electronics 4 isolated Electronics and Electrical Connections The electronics and their connections are isolated from one an other Moisture in the conduit will not get into the electronics 5 Five Year 5 Powered Up Warranty Time without power is not counted in the warranty No other manu facturer offers a run time warranty Siemens transmitters available for gauge pressure differential pressure and level Protect your transmitters Welded metal seals welded diaphragms for low pressure saddle flange welded diaphragms all these and more Call 800 953 7626 Orderyour transmitter with a chemical seal or diaphragm any material or configura tion you need we ll build it See pages 434 and 435 for chemical seals fill fluids and calibration services Call Inside Sales in our Bensenville office for full details 800 953 7626 Features e Micro machined silicon sensor technology means no span shift and zero stability better than 0 25 for up to 5 years e Nine field selectable parameter values can be accessed via magnetically coupled reed switches for field con figuration without a handheld programmer e Diagnostics include operating hours meter two indepen dent elapsed time counters for monitoring calibration and maintenance internals and six registers store values for ambient temperature electronics capsule tempera ture process and capsule pressure data Program wit
28. an be added or removed in the field For easier access and visibility the display can be mounted and adjusted to 0 90 180 and 270 degree posi tions The two line 16 character LCD can display any one of 16 standard engineering units plus square root output indication Suitable for all electrical and environmental requirements SmartLine offers the ability to zero and span the transmitter from three externally accessible buttons With the display option these buttons also let you configure the transmitter and display Using a handheld Honeywell MCT202 configurator and Smartline transmitter two way communications you can field configure DE and HART devices Or if you prefer you can use Honeywell s SCT3000 con figuration toolkit and a PC to configure Honeywell Digitally Enhanced DE instruments Field Device Manager FDM software and FDM Express are available for managing HART and Fieldbus device configurations ST700 transmitters integrate with Honeywell s Experion PKS control software platform for tamper reporting FDM plant area views and health summaries To help control maintenance and inventory costs Honeywell ST700 transmitters are modular giving you the ability to replace meter bodies add indicators or change electronics modules without affecting overall performance or approval certification Each meter body is uniquely characterized to provide in tolerance performance over arange of varying temperatures and pressures Due t
29. check a current loop the SITRANS P can i ce be put into a current source mode to make loop checkout easy e Variety of remote seals for special appli cations such as measurement of highly No hard work with HART If you prefer you can also use the HART protocol to set all the trans mitter parameters using a HART communicator laptop PC or any HART compatible process control system Using HART all parameters and diagnostic information can be viewed at any point in the signal loop Siemens SIMATIC PDM software makes this even easier for the user Convenient replacements Since sensor specific data is stored in the SITRANS P s measuring cell the potted electronics module can be replaced without any problems And in the event of any trouble the 100 1 turndown allows a single transmitter to serve as a backup to many different ranges reducing your inventory quantity and the cost of spares Sound and certified durability Extreme pressures and temperatures and generally aggressive ambient conditions the SITRANS P can take it all It s certified and approved by organizations all over the world CENELEC FM CSA and more Safety standards with a single device The SITRANS P DS III features a special safety standard for pressure differential pressure absolute pressure and level Advanced diagnostic functions and software were developed in compliance with IEC standards Safety related functions include a
30. d High Side Left Low Side Right Connect Low Side Left High Side Right Pressure Transmitter FORO FOSNOF Orientation High Side Left Low Side Right 90 Head Rotation 7 F Fa i EF Si Approvals No Approvals Required 3 C O Im E FM Approved a E H CSA Approved or H H F OVO LOW z ATEX Approved E Electronic 1 2 NPT Aluminum E C Housing 1 2 NPT Aluminum with Lightning Protection Z Outputs 4 20mA DC and HART 67 00 aU 4 20mA DC and Honeywell DE 181 00 7 Indicator No Indicator or Buttons k and No Indicator External Zero Span Buttons Interface Indicator Indicator External Zero Span Config Buttons Failsafe Fail Mode High N Write Fail Mode Low Cc Protect Fail Mode High Write Protect Enabled 22 Fail Mode Low Write Protect Enabled E Y Mounting None n Bracket Angle Bracket Carbon Steel ne Angle Bracket 304SS oO Flat Bracket Carbon Steel V amp Displays provide PV Flat Bracket 304SS bargraphs trend lines Tagging None and text messages One Wired SS Tag 4 lines x 26 char line for diagnostics and Two Wired SS Tag 4 lines x 26 char line maintenance Conduit None 2 Plugs 1 2 NPTM to 3 4 NPTF 316 SS Conduit Adapter F Adapters 1 2 NPT 316 SS Certified Conduit Plug Eu Minifast 4 Pin 1 2 NPT not for X Proof use 7 Certificates Calibration Test amp Cert of Conformance F3399 e D Certificate of Origin F0195 WY FMEDA SIL 2 3 Certification FC33337
31. d CS Head 316L SS Diaphragm 316 SS Head 316L SS Diaphragm Fill Fluid Silicone Oil DC 200 Fluorinated Oil CTFE Process None Connection 1 2 NPT Female Bolt Nut Carbon Steel Materials 316 SS Grade 660 NACE A286 NACE 304 SS Nuts Head Type Single Ended Vent Drain Single Ended Side Drain and Vent Position Single Ended Side Drain Center SS Vent Dual Ended End Drain and Vent Dual Ended End Drain Center SS Vent Dual Ended Gasket Teflon or PTFE Glass Filled Viton or Fluorocarbon Elastomer r 7 Graphite Dimensions Head High Side Left Low Side Right Connect Low Side Left High Side Right Orientation High Side Left Low Side Right 90 Head Rotation e 2X 0 57 Approvals No Approvals Required 1 R FM Approved CEK J a T CSA Approved NS e LY 0795 ATEX Approved al Electronic 1 2 NPT Aluminum Housing 1 2 NPT Aluminum with Lightning Protection C_ Outputs 4 20mA DC and HART 67 00 4 20mA DC and Honeywell DE 181 00 Indicator No Indicator or Buttons and No Indicator External Zero Span Buttons Interface Indicator Indicator External Zero Span Config Buttons Failsafe Fail Mode High Write Protect Fail Mode Low Fail Mode High Write Protect Enabled Fail Mode Low Write Protect Enabled Mounting None Bracket Angle Bracket Carbon Steel Angle Bracket 304SS Flat Bracket Carbon Steel Flat Bracket 304SS Tagging None One Wired SS Tag 4 lines x 26 char line Two Wired SS Tag 4 lines x
32. do the calibration or service 1 Do you have transmitters that you deem so important that they must be serviced or calibrated on a routine basis How do you keep track of that requirement c Data Storage The transmitter has six registers that store high low input pressures and high low sensor and electronics temperatures Values can be recalled with the HART communicator 1 During troubleshooting these values can help determine if the unit has been exposed to pressure spikes or temperatures outside of spec 2 These values can diagnose if the transmitter failure is an ap plication problem or a hardware problem 3 How do you sort out application problems from hardware problems now d Output Current Saturation Alarms Timers can drive the output to alarm status if the output saturates or stays at 3 8 or 20 5 mA fora preset time 1 What alarm functions are available on the product you are currently using 2 If there are no alarms available on your transmitter how are alarms accomplished 3 Do you use pressure switches or additional transmitters What Makes Siemens Transmitters Different 1 Local Setup Without Handheld or Screwdriver 3 Electronics and Pressure Capsule Are Independent Siemens electronics are encapsulated and are a modular unit Process media can t get into the electronics The electronics can be replaced easily because the transmitter data is stored in the mea suring capsule and automatically uplo
33. dules for instrument adjustment are called DTMs This configuration makes modern and user friendly adjustment concepts possible because the interface for instrument adjustment is optimally adapted to each instrument Furthermore you can communicate with PACTware not only via HART but also via any standard field bus system To this end different so called communication DTMs are available In PACTware these instrument and communication DTMs are assembled individually according to the given requirements PACTware enables open comprehensive adjustment of different field instruments via any bus system For which fieldbusses is PACTware suitable PACTware can beimplemented in process as wellas plant automation The prerequisite is a bus system that can transmit apart from actual values process data also parameter adjustment data communication DTMsare already available for the following fieldbusses and communication types e HART e Modbus standard communication RS232 e Ethernet e PROFIBUS PA e Foundation Fieldbus e ControlINET e DeviceNET CIP e AS Interface e Interbus e Various proprietary networks HART communications without busting the budget The HART communication protocol has been firmly established as the standard means of configuring field instruments for some years But talking to a field instrument needs a communicator There are the handheld communicators Rose mount s x75s and the budget p
34. e Ex Il 2G EEx ia IICT4 Type n Ex II 3G EEx nL IIC T4 Dust ignition proof Ex Il 2D T990C IP65 Ex Il 3D T550C IP65 Kit includes Pocket PC hardware two stylus pens LGx10 charger integrated HART DE modem USB interface kit with charger cable 4 foot transmitter connector cable clips and user manual CD ROM Model Selection Guide Catalog Description Number MC Toolkit Rugged Communications Configurator MCT202 ZZ Approvals None FM Class 1 Div 1 Intrinsically Safe FM Class 1 Div 2 Non Incendive ATEX Zone 1 Div 1 IS Dust lgnition Proof ATEX Zone 2 Div 2 Type N Universal Power Adapter Printed User Manual 00 UM 22 00 Note Not suitable for programming the Honeywell SMV3000 smart multivariable mass flowmeter Please see SCT3000 smart configuration toolkit Level Measurement Instruments Flow Measurement Instruments ap b Y E 40 U ep N 7a ap pas Q Temperature Sensors and Transmitters Communications Wireless Sensing and Analytical Instruments and Systems PROGRAMMING 96 a TOOLS P SIMATIC PDM Configuration and Diagnostic Software 3 SIEMENS 2 E paree T isine ae al rad TS i x ive air RAGE PANNE dae fr ATE SR RUAT FRM FN i d Faja rh ans SSSA HT ahd piabaridexk Re Deks ti s ding Hai i SS dh SS SIMATIC PDM Process Device Manager is a uni
35. e diagnostics calibra tion displaying device parameters selecting ppmmmmmmm communications mode Build and store f configurations offline even before the transmitter arrives at your plant Kit includes DE HART modem RS 232 cable 50032086 001 specified cable length instal lation guide and software Model Selection Guide Catalog Number 5 Configuration Toolkit 6 Ft Cable CT101 002 44 XXXX 3237 00 i i SCT101 012 44 XXXX 3273 00 Configuration Toolkit 20 Ft Cable SCT3000 Cable Kit Installation Guide 50033453 501 151 00 A meriam fam MFC 5150 HART Handheld Communicator Full QWERTY keyboard e Just 15 seconds from power up to use e General purpose and intrinsically safe models available No annual subscription required for firmware or DDF updates e 8GB SD card holds DD files for more than 1200 compatible field instruments e Replaces retired MFC 4150 e Rechargeable Lithium lon batteries Average 10 hour continuous use e Document and store clone upload and download Offline mode for editing and reviewing configurations e Update firmware and device files for free for HART devices from Meriam s website Model Selection Guide Description catalog Number Price Intrinsically Safe HART Communicator MFC5150X 5500 00 All communicator kits include Handheld communicator charger USB dock PC utility software USB cable HART leads carrying case and wrist strap
36. ecast Aluminum Housing Stainless Steel Approvals None FM CSA Intrinsic Safety Explosion Proof Conduit M20 x 1 5 Not Available with FM CSA 1 2 14 NPT Select with approval 1N Built in Indicator None Digital LCD Set to mA Digital LCD Set per Option Y21 Accessories For all accessories add Z and accessory code to model number Transmitter with Carbon Steel Mounting Bracket A01 Transmitter with Stainless Steel Mounting Bracket A02 Rating Plate Pressure Units in H20 Respective to PSI B21 Manufacturer s Test Calibration Certificate ISO 8402 C11 Acceptance Test Material Certificate EN 10204 C12 Test Report EN 10204 2 2 C14 Calibrated Measuring Range Please Specify YO Tag Number 16 Characters Maximum Y15 Measuring Point Description 27 Characters Max Y16 Set LCD Specify Units PSI InH2O FtH2O Y21 units Level Measurement Instruments Flow Measurement Instruments en VU Par i g0 VU D N a VU ae Temperature Sensors Communications and Transmitters Wireless Sensing and Analytical Instruments and Systems SJUSWINJSU jUaWaINseayy 2427 SJUdUWUNIISU jUaWaINseay MO p gt gt nn n a gt pe 3 nn ot gt s1 USULI pue SIOSUSS Inzes dw SUOI EDIUNLWUWO gt pue BHulsuas ssajadi SWa sKs pue SJUaWUNAYSU Je217 jeuy DIFFERENTIAL PRESSURE SITRANS P DS III Differential Pressure Transmitt
37. eing di rectly connected to the instrument It works fine connected at the marshalling panel control panel or wherever wiring terminations for loop can be found The power of PC offers two key advantages over a handheld e The configuration parameters are listed in an overview form e Ona PC the graphics can offer more than a handheld like echo profiles for non contact radar or ultrasonic level instruments So if you think a HART handheld is a budget buster in your world consider Pactware and a HART modem as your HART communica tions tool How is PACTware different from other engineering tools A lean efficient tool for parameter adjustment of field instruments e Intuitive adjustment diagnostics andasset managementfunctionality e Can be equipped with additional functionality via so called add ins e Supports the full range of functions of all field instruments e Offers diagnostics and asset management functionality e Simplifies setup in automation e Software is free of charge all you need is a HART modem 449 65 591 10 Connection Devices Catalog Number HART Siemens RS 232 HART Modem 7MF4997 1DA Modems Siemens USB HART Modem 7MF4997 1DB Honeywell Programming Tools for Smart Transmitters SCT3000 Smart Configuration Toolkit For Honeywell smart pressure and smart temperature transmitters SMV3000 multivariable transmitters and MagneW flowmeters Use on line mode for field configuration devic
38. erent connector Large quantity requirement Call for pricing and availability 0 15 PSI 0 25 PSI 0 50 PSI 0 100 PSI 0 200 PSI 0 300 PSI 0 500 PSI 0 1000 PSI 0 1500 PSI 0 2000 PSI 0 3000 PSI 0 5000 PSI 0 10000 PSI 50426397 50426401 50426427 50372475 50398083 50426460 50426478 50426486 50426494 50426508 50426516 50372483 50426532 50426770 50426788 50426800 50426818 50426834 50426842 50426851 50426869 50426877 50426885 50426893 50426907 50426915 Pressure Transmitters for OEM Applications Features e 0 5 accuracy e Two wire 4 20 mA output standard e CE Mark option available Model Selection Guide Pressure Maximum Burst Catalog Range Pressure Pressure Number C 10 Transmitter 316 SS Wetted Parts Piezo Resistive Sensing Element and 1 4 NPT Male Pressure Connection Two Wire 4 20 mA Output These OEM application pressure transmitters feature a highly stable temperature compen sated conditioned output signal With a stainless steel case and compact design they provide a high performance sensor package with excellent vibration resistance and long service life Specifications Accuracy 0 5 full span Linearity lt 0 5 Hys teresis lt 0 1 span Repeatability lt 0 05 span One Year Stability lt 0 2 span Operating Temperature 14 to 176 F ambient 22 to 212 F media Power Supply 12 30 VDC Output 2 wire 4 20 mA DC 3 wire 0 20 mA 0 5V or 0 10V output opt
39. ers as r Features e Capsule stability is ensured because micro machined SI E M E N S silicon sensor technology means no span shift and zero stability better than 0 25 for up to 5 years 9 field selectable parameter values can be accessed via magnetically coupled reed switches for field configuration without a handheld programmer 84 E 4 ht 4 e Diagnostics include operating hours meter 2 independent elapsed time counters for monitoring calibration and maintenance intervals and 6 registers store values for ambient temperature electronics capsule temperature process and capsule pressure data Program with three local input keys or with external HART communications link viscous substances Reliability for the process reduced downtime for your plant higher quality for the produced goods Can a transmitter make a big differ ence Yes once it makes the step from a simple value indicator to a value analyzer like the SITRANS P It s the first transmitter with inte grated diagnostic functions so it can monitor itself and other process conditions at regular intervals Advanced transmitter diagnostics with SITRANS P means e Dual elapsed time registers These can be set up to signal when preventative maintenance or calibration is required e Three freely adjustable limits So you can implement pre alarms or monitor temperature e Record of limit violations Based on maximum
40. es dw SUOI EDIUNWIWO gt pue Bulsuas ssajadi SWa sKs pue SJUaWUNAYSU Je217 jeuy GAUGE 92 PRESSURE STG700 SmartLine Gauge Pressure Transmitter Features e Accuracies to 0 065 of span e Stability up to 0 02 URL per year for 5 years e Maximum turndown ratio to 100 1 e Response times as fast as 100ms e Alphanumeric display capabilities e External zero span and configura tion capability e On board diagnostic capabilities e World class overpressure protection e Compliant to SIL 2 3 requirements ay ad 3 e Polarity insensitive electrical connections e Automatic temperature compensation STG90L STG94L Integral dual seal design for highest 516974 and STGS7L safety based on ANSI NFPA 70 202 and ANSI ISA 12 27 0 e Honeywell DE HART v7 0 and Foundation Fieldbus commu nications options Honeywell s new SmartLine STG700 and STG670L are suitable for monitoring control and data acquisition STG7OX products feature piezoresistive sensor technology combining pressure sensing with on chip temperature compensation capabilities providing high accuracy stability and performance over a wide range of application pressures and temperatures The SmartLine family is also fully tested and compliant with Experion PKS automation and control software platform providing the highest level of compatibility assurance and integration capabilities The ST700 modular features a basic alphanumeric LCD display that c
41. et PC Based DE HART Configurator 7423 00 95 g Meriam MFC5150 HART Handheld Communicator 5200 00 96 4 z PACTware Configuration Software FREE 94 we Siemens Simatic PDM Configuration Diagnostics Software 77 00 96 WIKA Loop Powered Digital Indicator 295 74 79 Need for a submersible transmitter for liquid level See pages 16 and 17 Looking for Honeywell s smart multivariable transmitter for flow See page 63 Analytical Instruments and Systems S u UNIJSU jUaWaINSea y 2497 s u UNISU jUaWaINsea MO o D wa V D g 7 at D lt SJayjiuusuel pue SIOSUSS Inzes dw SUOI EDIUNWUWO gt pue BHulsuas ssajadi SWa sKs pue SJUaWUNAYSU Je21 jeuy 78 PRESSURE TRANSMITTERS Low Cost All Stainless Pressure Transmitters Model Selection Guide 4 20 mA 2 Wire Price Features e Ranges from 0 15 to 0 10000 PSIG 0 15 to 0 300 PSIA e lt 0 5 span accuracy e 4 20 mA or 0 10 V output 0 10V 3 Wire Model Model Price A 10 Pressure Transmitter 1 4 NPTM Process Connection 0 15 PSIA 50426354 194 28 50426737 194 28 0 100 PSIA 50426389 194 28 50426761 194 28 e 316L stainless body silicone oil internal fill pressures to 0 100 PSIG 0 300 PSIA e 10 30 VDC power supply e Pressure connections 1 4 NPT standard 1 2 NPT SAE 4 e Operating range 32 to 176 F e UL CSA and GOST approved ROHS and CE conformity Need a diff
42. h three local input keys or with external HART communications link e Remote seals available for special applications like measure ment of highly viscous substances Specifications Output Signal 4 to 20 mA Lower Limit 3 55 mA factory set to 3 84 mA Upper Limit 23 0 mA factory set to 20 5 mA or optional 22 0 mA Ripple without HART pp 0 5 of max output current Electric Damping Adjustable time constant T63 0 to 100 s in steps of 0 1 s factory set to 0 1 s Current Transmitter Signal on Alarm Adjustable from 3 55 to 23 mA Load Without HART Rg UH 10 5 V 0 023 A in Q UH power supply in V With HART Rg 230 to 500Q modem 230 to 1100Q communicator Temperature Measuring cell with silicone oil filling 40 to 185 F 30 bar measuring cell 4 to 185 F Digital display 22 to 185 F Measuring cell with inert filling liquid 4 to 185 F Displays and Controls nput keys 3 for local programming directly on transmitter Digital display Built in cover with window option Power Supply Terminal voltage on transmitter DC 10 5 to 45 V and DC 10 5 to 30 V in intrinsically safe mode Ripple Upp 0 2 V 47 to 125 Hz Noise U rms 1 2 mV 0 5 to 10 kHz Communication HART Communicator 230 to 11000 Modem 230 to 500Q Cable 2 wire screened 3 0 km Multi core screened 1 5 km PC Laptop Requirements IBM compatible main memory gt 32 MB hard disk gt 70 MB RS232 interface VGA graphics Operati
43. ide Right Connect Low Side Left High Side Right Orientation High Side Left Low Side Right 90 Head Rotation Pressure Transmitter N Approvals No Approvals Required Ou FM Approved CoO CSA Approved g E ATEX Approved u Electronic 1 2 NPT Aluminum A__ 2 Housing 1 2 NPT Aluminum with Lightning Protection C_ is U Outputs 4 20mA DC and HART 67 00 eu 4 20mA DC and Honeywell DE 181 00 E Indicator No Indicator or Buttons im and No Indicator External Zero Span Buttons Interface Indicator Indicator External Zero Span Config Buttons Failsafe Fail Mode High g p Write Protect Fail Mode Low c Fail Mode High Write Protect Enabled 22 Fail Mode Low Write Protect Enabled a hy ew Mounting None g a Va Bracket Angle Bracket Carbon Steel A E FOSNO Angle Bracket 304SS U T im me jli Flat Bracket Carbon Steel v O a Flat Bracket 304SS E A OYO Tagging None One Wired SS Tag 4 lines x 26 char line Two Wired SS Tag 4 lines x 26 char line None 1 2 NPTM to 3 4 NPTF 316 SS Conduit Adapter 1 2 NPT 316 SS Certified Conduit Plug Minifast 4 Pin 1 2 NPT not for X Proof use Certificates Calibration Test amp Cert of Conformance F3399 Certificate of Origin FO195 FMEDA SIL 2 3 Certification FC33337 Documen Printed English User Manual 34 ST 25 35 tation HART DE Communications Manual 34 ST 25 38 Safety Manual 34 ST 25 37 Function Block Manual 34 ST 25 42 Instrument
44. internal soft sealing materials that can react with the media or deteriorate over time F 21 s flat sensing surface is designed for measuring viscous fluids or media containing solids that may clog the NPT process connection 5 gt nn n a gt a pe n ot 9 FM Approved Explosion Proof Transmitters for Hazardous Areas WIKA E 10 explosion proof pressure transmitters are specifically de signed to meet the durability and performance requirements of oil and Features gt FM approved explosion proof for Class Division 1 ae maa a gas pressure monitoring applications 23 hazardous locations an These pressure transmitters feature an industry standard 4 20 mA S Available with 4 20 mA two wire or 1 5 V three two wire or 1 5V three wire low power signal output and NEMA 4X 3 wire low power output signals IP67 ingress protection They are extremely resistant to pressure spikes 3 Engineered to withstand harsh environments vibration and moister intrusion m D NACE MR0175 compliant wetted parts NACE MR 01 75 compliant wetted parts provides extra resistance aS o o against sulfide stress cracking when exposed to media containing sulphur a Retrofits many existing oil and gas applications Both are available with a factory sealed epoxy flying lead assembly for Specifications easier installation Materials Wetted parts NACE compliant Model E 10 Stainless Model Selection Guide
45. ional Process Connection Size 1 4 NPTM standard Materials Body 304 Stainless steel Wetted Parts 316 or 17 4PH and 316 Stainless steel Transmitting Liquid Silicone oil Electrical Connection Mini DIN plug NEMA 5 IP65 Electrical Protection Protected against reverse polarity short circuit output 0 100 WC 0 5 PSIG 0 15 PSIG 0 25 PSIG 0 50 PSIG 0 60 PSIG 0 100 PSIG 0 150 PSIG 0 200 PSIG 0 300 PSIG 0 500 PSI 0 600 PSI 0 1000 PSI 0 1500 PSI 0 2000 PSI 0 3000 PSI 0 5000 PSI 0 7500 PSI 0 10 000 PSI 0 15 000 PSI 30 PSI 30 PSI 70 PSI 145 PSI 245 PSI 245 PSI 500 PSI 500 PSI 500 PSI 725 PSI 1160 PSI 1160 PSI 1740 PSI 2900 PSI 2900 PSI 7250 PSI 11 600 PSI 17 400 PSI 17 400 PSI 21 750 PSI 30 PSI 30 PSI 70 PSI 145 PSI 245 PSI 245 PSI 500 PSI 500 PSI 500 PSI 3625 PSI 5800 PSI 5800 PSI 7975 PSI 11 600 PSI 11 600 PSI 17 400 PSI 24 650 PSI 34 800 PSI 34 800 PSI 43 500 PSI 4204883 8363434 8363442 8363450 8363468 8363476 8363515 8363485 8363493 8363506 9697688 8357247 8357255 8357264 8357272 8354753 M 8347390 8357280 8357298 8359576 275 71 275 71 275 71 275 71 275 71 275 71 275 71 275 71 275 71 C 10 Transmitter 316 and 17 4pH SS Wetted Parts Thin Film Sensing Element and 1 4 NPT Male Pressure Connection Two Wire 4 20 mA Output and suppressor diode for high voltage protection 3 wire voltage and cur rent outputs are EMI protected per
46. ithout damping Per IEC60770 1 field or pipeline high vibration level Electromagnetic Compatibility IEC 61326 3 1 Lightning Protection Option Leakage Current 10uA max 42 4 VDC 93C Materials Barrier Diaphragms 316L SS Hastelloy C 276 Monel 400 Tanta lum Process Head 316 SS Carbon Steel Zinc plated Hastelloy C 276 Vent Drain Valves and Plugs 316 SS Hastelloy C 276 Head Gaskets Glass filled PTFE standard Viton graphite optional Meter Body Bolting Zinc Plated Carbon Steel standard 316 SS NACE A286 SS bolts Mounting Bracket 2 Pipe Carbon Steel Zinc plated or 304 Stainless Steel Fill Fluid Silicone DC 200 oil or CTFE Electronic Housing Pure polyester powder coated low copper aluminum Meets NEMA 4X IP66 IP67 and NEMA 7 All stainless steel housing is optional Mounting Can be mounted in virtually any position using a standard mount ing bracket Bracket is designed to mount on 2 vertical or horizontal pipe Process Connections 1 2 NPT or 1 2 NPT with DIN adapter Wiring Accepts up to 16 AWG 1 5 mm diameter Enclosure Type 4X IP66 IP67 Communication Diagnostics HART 7 Foundation Fieldbus Honeywell DE Agency Approvals FM CSA Explosion Proof Class Div 1 Groups A D Dust Ignition Proof Class Il III Div 1 Groups E G T4 Intrinsically Safe Class II Ill Div 1 Groups A G T4 Non Incendive Class Div 2 Groups A D ATEX Flameproof Il 1 2 G Ex d IIC T4 Intrinsically Safe
47. m See page 95 Level Measurement Instruments Temperature Sensors Pressure Transmitter Flow Measurement Communications and Transmitters Instruments Wireless Sensing and Analytical Instruments and Systems SJUSWINJSU JUaWaINseayy 2427 SJUDUNIYSU JUDWOINSPO A MO 5 D wa 7 D g 2 N t D s1 IUSULI pue s4osu JINJeJodWwa SUOI EDIUNWUWO gt pue Bulsuas Ssajadi SWa sKs pue SJUaWUNAYsU Je217 jeuy PRESSURE 86 TRANSMITTERS STD700 SmartLine Differential Pressure Transmitter How does the STD700 stack up Model SmartLine ST700 ST3000 Series 900 Accuracy 0 05 0 0625 digital mode 0 075 analog Features e Accuracies to 0 05 of span e Stability up to 0 02 URL per year for 5 years e Automatic static pressure amp tem perature compensation e Maximum turndown ratio to 100 1 e Response times as fast as 100ms Alphanumeric display can be added or removed in the field e External zero span and configura tion capability e On board diagnostic capabilities e World class overpressure protection e Polarity insensitive electrical connections e Integral dual seal design for highest safety based on ANSI NFPA 70 202 and ANSI ISA 12 27 0 i Replaces ST3000 e Compliant to SIL 2 3 requirements models STD904 STD924 STD930 Honeywell DE HART v7 0 and Foundation and STD974 Fieldbus communications options Honeywell s new SmartLi
48. ne STD700 differential pressure transmitters feature piezoresistive sensor technology combining pressure sensing with on chip temperature compensation for high accuracy stability and performance overa wide range of application pressures and temperatures The SmartLine family is also fully tested and compliant with Experion PKS automation and control software platform providing the highest level of compatibility assurance and integration capabilities The ST700 modular features a basic alphanumeric LCD display that can be added or removed in the field For easier access and visibility the display can be mounted and adjusted to 0 90 180 and 270 degree posi tions The two line 16 character LCD can display any one of 16 standard engineering units plus square root output indication Suitable for all electrical and environmental requirements SmartLine offers the ability to zero and span the transmitter from three externally accessible buttons With the display option these buttons also let you configure the transmitter and display Using a handheld Honeywell MCT202 configurator and Smartline transmitter two way communications you can field configure DE and HART devices Or if you prefer you can use Honeywell s SCT3000 con figuration toolkit and a PC to configure Honeywell Digitally Enhanced DE instruments Field Device Manager FDM software and FDM Express are available for managing HART and Fieldbus device configurations ST70
49. ng system Windows 95 98 NT 4 0 and SIMATIC PDM Approvals CENELEC DIN EN 50 014 1997 EN 50 020 1994 and EN 50 284 1999 FM Intrinsic safety and explosion proof 3008490 3610 3615 Explosion proof Class Div 1 Groups A D Dust ignition proof Class Il Div 1 Groups E G indoor and outdoor NEMA 4X hazardous classified locations Intrinsically safe With entity for use in Class l Div 1 Group A G indoor and outdoor NEMA APPROVED 4X hazardous classified locations CSA No 1153651 LR104225 Class 2258 02 Class 2258 03 Looking for differential pressure transmitters See page 84 Need a level transmitter Turn to page 16 GAUGE PRESSURE 83 SITRANS P DS III Gauge Pressure Transmitters Ordering Instructions Select one option from each table section below A complete catalog number looks like this 7MF4033 Model Selection Guide Catalog Number 1174 38 0 00 113 22 Description SITRANS P DS III Programmable Smart Pressure Transmitter with HART 7MF4033 Fill Silicon Oil 1 Fluid Fluorolube Grease Free span Overload Limit 0 15 to 15 14 5 to 87 0 6 to 60 14 5 to 145 2 3 to 232 14 5 to 465 9 1 to 924 14 5 to 1450 2 3 to 2320 14 5 to 3625 58 0 to 5800 14 5 to 8700 Stainless Steel Stainless Steel Hastelloy Stainless Steel Hastelloy Hastelloy Pressure PSI Model with Remote Seal 1 2 14 NPTF Process Connection for Manifold Electronics Di
50. ntrinsically safe mode Ripple Upp 0 2 V 47 to 125 Hz Noise U rms 1 2 mV 0 5 to 10 kHz Ripple without HART pp 0 5 of max output current HART Communicator 230 to 11000 Modem 230 to 500Q Differential Pressure Ordering Instructions Select one option from each table section below A complete catalog number looks like this 7MF4433 Model Selection Guide Number SITRANS P DS III Differential Pressure Transmitter 7MF4433 Fill Silicon Oil 1 Fluid Inert Fill Static Pressure 465 PSI 2320 PSI 2320 PSI 2320 PSI 2320 PSI 2320 PSI 2320 PSI Meas Cell Stainless Steel Stainless Steel Hastelloy Tantalum Monel Monel Gold Gold 1 4 18 NPT Process 7 16 20 UNF Manifold 1 4 18 NPT Side Drain Vent 7 16 20 UNF Electronics Housing Catalog 1589 19 0 00 113 22 0 4 to 8 H20 0 4 to 24 H20 1 0 to 100 H20 2 4 to 241 H20 6 4 to 643 H20 20 0 to 2000 H20 4 3 to 435 PSI Diaphragm Pressure Stainless Steel Hastelloy Hastelloy Tantalum Diecast Aluminum SS Flange Bolts Stainless Steel SS Flange Bolts proses erea oo ii None FM CSA Intrinsic Safety Explosion Proof M20 x 1 5 Not Available with FM CSA 1 2 14 NPT Select with Approval 1N None Hidden Digital Display Digital LCD Set to mA Digital LCD Set as Specified Accessories For all accessories add Z and accessory code to model number A01 A02 B2
51. o Indicator External Zero Span Buttons Interface Indicator F Indicator External Zero Span Config Buttons Dimensions Failsafe Fail Mode High 4 96 W DISPLAY Write Protect Fail Mode Low Fail Mode High Write Protect Enabled Fail Mode Low Write Protect Enabled Mounting None 1 79 Bracket Angle Bracket Carbon Steel Angle Bracket 304SS Flat Bracket Carbon Steel Flat Bracket 304SS Tagging None One Wired SS Tag 4 lines x 26 char line Two Wired SS Tag 4 lines x 26 char line Conduit None Plugs 1 2 NPTM to 3 4 NPTF 316 SS Conduit Adapter Adapters 1 2 NPT 316 SS Certified Conduit Plug Minifast 4 Pin 1 2 NPT not for X Proof use Certificates Calibration Test amp Cert of Conformance F3399 Certificate of Origin FO195 FMEDA SIL 2 3 Certification FC33337 EXTERMAL 4 59 GROUND j a Documen Printed English User Manual 34 ST 25 35 Restrictions tation HART DE Communications Manual 34 ST 25 38 j Available only with HART digital output Requires Safety Manual 34 ST 25 37 write protection enabled Function Block Manual 34 ST 25 42 Level Measurement Instruments Temperature Sensors Pressure Transmitter Flow Measurement Communications and Transmitters Instruments Wireless Sensing and Analytical Instruments and Systems SJUSWINASU JUaWaINsSeayl 2427 SJUSWNIISU jUaWaINseayy MO o D wa V D j g V at D SJajiuusuel pue SIOSUSS Inz
52. o store transmitter configurations on your PC Here are the big deal things you can do without a handheld a Set up Zero and Span without applying pressure b Loop Function Check Use the transmitter as a current source so the tech doesn t need another device to check out a loop We don t know of any other transmitters that can do this c Zero Adjustment Transmitters mounted in non vertical positions have zero shift This can be corrected using the pushbuttons All other manufacturers require a HART communicator to make this correction d Failure Current Set the transmitter to send a failure current 3 6 or 22 8 mA in the event that hardware or firmware fails It works like thermocouple burnout The failure current drives the valve to a user selected safe open or closed position 1 Have you ever hada transmitter fail and cause an unsafe condi tion in your plant 2 What does the transmitter you are currently using do if it has a hardware or firmware failure 2 Advanced Diagnostics with a HART Communicator You can activate and evaluate a number of diagnostics functions a Operating Hours Meter Logs the number of hours the unit has been powered to track the 5 year on power warranty b Dual Elapsed Timers The first timer stage can be set to make the indicator flash and advise that it s time to calibrate the transmitter A second timer stage can send a fault current 3 6 or 22 8 mA to remind you to
53. o the Honeywell advanced interface electronic modules may be swapped with any electronics module without losing in tolerance performance characteristics Replaces retired models Specifications Reference Accuracy 0 065 span Stability YURL year for five years 0 020 Temperature Ambient 40 to 185 F Meter Body 40 to 257 F LCD 4 to 158 F Humidity 0 to 100 RH Vacuum Region Pressure 1 WC min absolute 2 hours at 158 F Maximum Allowable Working Pressure MAWP Units can withstand overpressure of 1 5 x MAWP without damage Analog Output Two wire 4 to 20 mA HART amp DE Transmitters only Digital Communications Honeywell DE HART 7 protocol or FOUNDATION Fieldbus ITK 6 0 1 compliant Output Failure Normal Limits 3 8 to 20 8 mA Honeywell standard or 3 8 to 20 5 MA NAMUR NE 43 Compliant Failure Mode lt 3 6 mA and 221 0 mA Supply Voltage 10 8 to 42 4 VDC at terminals IS versions limited to 30 VDC Voltage Effect 0 005 span per volt Transmitter Turn On Time HART or DE 2 5 seconds Foundation Fieldbus Host dependent Includes power up and test algorithms Response Time Delay Time Constant HART or DE 100 mS Foundation Fieldbus 150 mS host dependent Damping Time Constant HART Adjustable from O to 32 seconds in 0 1 increments Default 0 50 seconds DE Discrete values 0 0 16 0 32 0 48 1 2 4 8 16 32 seconds Default 0 48 seconds Vibration Effect Less than 0 1 URL w
54. oe Documen Printed English User Manual 34 ST 25 44 S i Restrictions tation HART DE Communications Manual 34 ST 25 47 j Available only with HART digital output Requires Safety Manual 34 S1 25 37 write protection enabled Function Block Manual 34 ST 25 49 SJUSWINJSU JUaWaINsSeayy 2427 SJUSWINAISU jUaWaINsSeayy MO 0 5 D wa 7 D g V t D SJajiuusuel pue SIOSUSS Inzes dw SUOI EDIUNLWUWO gt pue Dulsuas ss JdM SWa sKs pue SJUaWUNAYSU Je217 jeuy PROGRAMMING TOOLS 94 PACTware Configuration Software for Field Instruments fh I a PLO tls ellen 8 eptoet OCS Centralised engineering m ELA r i te Segment coupler 1 SE Ramote S eet 2il Linking device vo 4 mii vo Communication capable field instruments Local control in the field What is PACTware PACTware is a manufacturer and fieldbus independent software for operating field instruments Up to nowitwas often necessary to use several different manufacturer specific programs to operate different field instruments to the full extent This is no longer necessary because PACTware enables adjustment of any and all field instruments with only one software tool PACTware uses a Standardised interface between the frame program and the individual software modules for instrument operation This inter face is known as FDT the software mo
55. opper aluminum Meets NEMA 4X P66 IP67 All stainless steel housing is optional Mounting Can be mountedin virtually any position using a standard mount ing bracket Bracket is designed to mount on 2 vertical or horizontal pipe Process Connections 1 4 NPT or 1 2 NPT with DIN adapter Wiring Accepts up to 16 AWG 1 5 mm diameter Enclosure Type 4X IP66 IP67 Digital Communications Diagnostics Honeywell DE HART 7 protocol or FOUNDATION Fieldbus ITK 6 0 1 compliant iy ou Agency Approvals FM CSA Explosion Proof Class Div 1 Groups A D Dust Ignition Proof Class Il III Div 1 Groups E G T4 Intrinsically Safe Class II Ill Div 1 Groups A G T4 Non Incendive Class Div 2 Groups A D ATEX Flameproof Il 1 2 G Ex d IIC T4 Intrinsically Safe II 1 G Ex ia IIC T4 Non Incendive II 3 G Ex nA IIC T4 Enclosure P66 IP67 SIL 2 3 Certification IEC 61508 SIL 2 for non redundant use and SIL 3 for redundant use according to EXIDA and TUV Nord Sys PRESSURE 87 TRANSMITTERS Ho neywell Ordering Instructions Make one selection from each table section below Follow the availability column down and check any restriction letters or notes to be sure the unit is available A finished catalog number looks like this Model 400 to 400 H20 4 0 to 400 H20 STD720 1384 00 Range Limits 100 to 100 PSI 1 to 100 PSI STD730 1558 00 Span 100 to 3000 PSI 30 to 3000 PSI STD770 1590 00 Meter Body Plate
56. proof Il 1 2 G Ex d IIC T4 Intrinsically Safe II 1 G Ex ia IIC T4 Non Incendive II 3 G Ex nA IIC T4 Enclosure P66 IP67 SIL 2 3 Certification IEC 61508 SIL 2 for non redundant use and SIL 3 for redundant use according to EXIDA and TUV Nord Sys PRESSURE 91 TRANSMITTERS Honeywell Ordering Instructions Critical Diag ENTI TN reg a DIFFERENTIAL Make one selection from each table section below Follow the availability column down and check Meterbody l any restriction letters or notes to be sure the unit is available A finished catalog number looks like this fault a os 0000 Good Ink 20 Model Selection Guide 400 Good nti ae ol 772 Description Number ability ig eae deg F Absolute 0 to 780 mm HgA 50 mm HgA STA822 ly 2363 00 ihe a g 248 200 Dual Head 0 to 500 PSI 5 PSIA STA840 J 2363 00 Clockwise f left Di c faul Meter Body Plated CS Head 316L SS Diaphragm A 0 00 ocKWISE OTOP tert rag Cote Aut MESsagesS targe 316 SS Head 316L SS Diaphragm 78 00 PV display for easy visibility bar graph view critical Fill Fluid Silicone Oil DC 200 0 00 Fluorinated Oil CTFE 57 00 SmartLine transmitter modular display is more Connection DIN 19213 1 4 NPT Female 0 00 0 00 47 00 diagnostics indicators Unique Indication Display Options than your typical standard LCD You get critical and Bolt Nut Carbon Steel non critical diagnostic
57. riced Meriam MFC 4150 but at a cost that s more a capital appropria tion than an MRO expense Even the Meriam with a 3 year field device description subscription starts at more than 4000 People ask if there isn t a more budget conscious approach to HART configuration rk f T Dan Weise Product Specialist There is Pactware a Windows application software that can talk HART to field instruments It s a free download with NO licensing fee Before you get started here s what you need to make it work Software use the Krohne version It runs in both XP and Windows 7 32 bit http www pactware com en products pactware html A HART modem to connect your PC to the field device use the Viator USB HART modem from MACTek It runs about 500 Download two files The first is a basic HART driver called a DTM that enables and manages HART communications througha HART modem http www codewrights biz A driver DTM for each model field instrument Instrument manufacturers are responsible for providing DTMs Ask the manu facturer whether a DTM is available and where to download it HART needs at least 230 ohms of loop resistance to operate when trying to connect with an instrument on the shop bench be sure to put a resistor in the loop it won t communicate with just an instru ment and a power supply A laptop with a HART modem is not usable in hazardous areas but the nature of HART allows communication without b
58. s Instruments Analytical Instruments and Systems SJUSWNJSU JUaWaINsSeayl 2427 SJUSWNIISU jUaWaINsSeayy MO 0 5 D WN V D j g V t D s1 USULI pue SIOSUSS JINJeJodWa SUOI EDIUNLWUWO gt pue BHulsuas ssajadi SWa sKs pue SJUaWUNAYSU Je217 jeuy PRESSURE 90 TRANSMITTERS STA800 SmartLine Absolute Pressure Transmitter Features e Accuracies to 0 055 of span e Automatic temperature compensation e Maximum turndown ratio to 100 1 e Response times as fast as 80ms Alphanumeric display can be added or removed in the field e External zero span and configura tion capability e On board diagnostic capabilities e World class overpressure protection e Integral dual seal design for highest safety based on ANSI NFPA 70 202 and ANSI ISA 12 27 0 e Polarity insensitive electrical connections e Compliant to SIL 2 3 requirements ra Replaces ST3000 e Honeywell DE HART v7 0 and Foundation i models STA122 Fieldbus communications options and STA140 Honeywell s new SmartLine STA800 absolute pressure transmitters feature piezoresistive sensor technology combining pressure sensing with on chip temperature compensation for high accuracy stability and performance overa wide range of application pressures and temperatures The SmartLine family is also fully tested and compliant with Experion PKS automation and control software platform providing the
59. s custom messages and up Materials 316 SS to eight screens for process variable formats Plus it Head Type Single Ended can be added removed and replaced easily in the Vent Drain Single Ended Side Drain and Vent field without removing the transmitter from service Position Single Ended Side Drain Center SS Vent Dual Ended End Drain and Vent Basic Alphanumeric LCD Display Features Dual Ended End Drain Center SS Vent Dual Ended e 0 90 180 and 270 degree position adjustments 16 standard measurement engineering units Gasket o or PTFE Glass Filled e 2 Lines 16 Characters 4 13 H x 1 83 W mm Graphite Square root output indication Head High Side Left Low Side Right r Connect Low Side Left High Side Right Advanced Gr aphics LCD D ISp lay Features Orientation High Side Left Low Side Right 90 Head Rotation e 0 90 180 and 270 degree position adjustments Approvals No Approvals Required Standard or custom measurement units FM Approved e Uptoeight display screens with three formats are CSA sida possible large display bargraph trend lines RIEA APDTOVE ni Electronic 1 2 NPT Aluminum A__ a A Housing 1 2 NPT Aluminum with Lightning Protection apa Savare Roos eapabimiescan pe setseba Outputs 20mADC and HART Ko ately tro urpu 7 Eaa 4 20mA DC and Honeywell DE D e Honeywell s unique Health Watch indication Indicator No indicator or Bunton provides instant visibility of diagnostics and N
60. tion Each meter body is uniquely characterized to provide in tolerance performance over a range of varying temperatures and pressures Because of Honeywell s advanced interface electronic modules can be swapped without losing in tolerance perfor mance characteristics Specifications Reference Accuracy 0 055 span Temperature Ambient 40 to 185 F Meter Body 40 to 257 F LCD 4 to 158 F Humidity 0 to 100 RH Vacuum Region Pressure 1 WC min absolute 2 hours at 158 F Maximum Allowable Working Pressure MAWP Units can withstand overpressure of 1 5 x MAWP without damage Analog Output Two wire 4 to 20 mA HART amp DE Transmitters only Digital Communications Honeywell DE HART 7 protocol or FOUNDATION Fieldbus ITK 6 0 1 compliant Output Failure Normal Limits 3 8 to 20 8 mA Honeywell standard or 3 8 to 20 5 mA NAMUR NE 43 Compliant Failure Mode lt 3 6 mA and 21 0 mA Supply Voltage 10 8 to 42 4 VDC at terminals IS versions limited to 30 VDC Voltage Effect 0 005 span per volt Transmitter Turn On Time HART or DE 2 5 seconds Foundation Fieldbus Host dependent Includes power up and test algorithms Response Time Delay Time Constant HART or DE 80 mS Foundation Fieldbus 150 mS host dependent Damping Time Constant HART Adjustable from O to 32 seconds in 0 1 increments Default 0 50 seconds DE Discrete values 0 0 16 0 32 0 48 1 2 4 8 16 32 seconds Default 0 48 seconds
61. ure Normal Limits 3 8 to 20 8 mA Honeywell standard or 3 8 to 20 5 mA NAMUR NE 43 Compliant Failure Mode lt 3 6 mA and 221 0 mA Supply Voltage 10 8 to 42 4 VDC at terminals IS versions limited to 30 VDC Voltage Effect 0 005 span per volt Transmitter Turn On Time HART or DE 2 5 seconds Foundation Fieldbus Host dependent Includes power up and test algorithms Response Time Delay Time Constant HART or DE 100 mS Foundation Fieldbus 150 mS host dependent Damping Time Constant HART Adjustable from O to 32 seconds in 0 1 increments Default 0 50 seconds DE Discrete values 0 0 16 0 32 0 48 1 2 4 8 16 32 seconds Default 0 48 seconds Vibration Effect Less than 0 1 URL without damping Per IEC60770 1 field or pipeline high vibration level Electromagnetic Compatibility IEC 61326 3 1 Lightning Protection Option Leakage Current 10uA max 42 4 VDC 93C Materials Barrier Diaphragms 316LSS Hastelloy C 276 Monel 400 Tanta lum Process Head 316 SS Carbon Steel Zinc plated Hastelloy C 276 Vent Drain Valves andPlugs 316SS Hastelloy C 276 Head Gaskets Glass filled PTFE standard Viton graphite optional Meter Body Bolting Zinc Plated Carbon Steel standard 316 SS NACE A286 SS bolts Monel K500 Super Duplex and B7M optional Mounting Bracket 2 Pipe Carbon Steel Zinc plated or 304 Stainless Steel Fill Fluid Silicone DC 200 oil or CTFE Electronic Housing Pure polyester powder coated low c
62. utomatic error diagnostics defined error handling and calculation of error rates You only need one SITRANS P DS III to set up the same oan i o safety level that you d normally get with two conventional i transmitters Thatmeansyousavethecostofanadditionaltransmitter includinginstallation and maintenance costs extra wiring and extra isolating power supplies Not to mention the cabinet space you safe Field tests in a number of applications has proven how well the DS III is suited for real life practice If you want a high level of safety and reliability put the SITRANS P DS IIl at the top of your list For HART communicators and SIMATIC PDM software see pages 95 and 96 Specifications Output Signal 4 to 20 mA Lower Limit 3 55 mA factory set to 3 84 mA Upper Limit 23 0 mA factory set to 20 5 mA or optional 22 0 mA Electric Damping Adjustable time constant T63 0 to 100 s in steps of 0 1 s factory set to 0 1 s Current Transmitter Signal on Alarm Adjustable from 3 55 to 23 mA Temperature Measuring cell with silicone oil filling 40 to 185 F 30 bar measuring cell 4 to 185 F Digital display 22 to 185 F Measuring cell with inert filling liquid 4 to 185 F Displays and Controls nput keys 3 for local programming directly on transmitter Digital display Built in cover with window option Power Supply Terminal voltage on transmitter DC 10 5 to 45 V and DC 10 5 to 30 V in i
63. versal tool for configura tp es Operon a eee oe eg APS tion parameterassignmentcommissioning diagnostics and maintenance Piacente of intelligent process devices and automation components i arpapi With SIMATIC PDM you can use one software program to configure a number of field devices by different manufacturers using a single user interface Process device data can be easily set changed checked for plausibility managed and simulated In addition you can monitor selected process values alarms and status signals of devices online S x M NN 7a D fe gt 7a e ar D D z S Major Advantages at a Glance 20 Simple operating system independent integration of field devices 32 based on device descriptions e g HART DD T A e Similar visualization of all field devices a e Provides basic functions e g export data comparison printing for 0 gt all feld devices Q e Communication with PROFIBUS DP PA HART or Modbus e No configuration knowledge required for parameter assignment and diagnostics of field devices via the LifeList Type independent and cross manufacturer field device parameter assignment and diagnostics A Supportofcomprehensive field device specificfunctions simulation 30 measuring circuit test characteristics curve definitions calibration s 3 functions documentation etc which can form the overall Model Selection Guide 2 characteristics of