Home

CBI-485220WA

image

Contents

1. E Approximately 10 cm computer 15 Interface Corporation CBI 485220WA Chapter 8 Troubleshooting 8 1 Checkpoints Data cannot be transferred Double check all cable connections correctly To use the multiple CardBus cards configure the CardBus ID number by using the CardBus ID utility program In case multiple Interface CardBus cards of the same type are installed in the same system the ID number on each Interface CardBus card is used to uniquely identify each card If the power requirements exceed the system power budget the circuits on the card or connected external circuits cannot be powered properly Prepare an external power supply for your CardBus card sure that there are no incorrect connections If the communications parameters for transmitter and receiver are not the same values the data cannot be correctly transmitted Configure them to be the same Communications are not Check whether the selected terminating resistor is suitable for your system reliable A transmit receive Refer to 3 4 External Input Output Circuit page7 error occurs The computer does not Use the PCI device viewer BPF 0801 to examine the CardBus card on your recognize this card computer Please send the result to our Technical Support Center by fax or e mail The PCI device viewer may be downloaded from our Web site free of charge The computer does not Set the System standby setting to Never
2. USER S MANUAL CBI 485220WA Two Channel High Speed CAN Interface Card FIFO with Termination nigh Pecan SJA1000 compatible communications rate 60 kbps to 1 Mbps CAN controller A AA A AAA PETSERRFEEEFENEERREEEEENFEFEEEEERERFERREFERR 64message TT transmit receive e I O transfer mode FIFO de Interface www interface co jp Notes to Users The specifications of the product are under continuous improvement and while every effort is made to keep this manual up to date we reserve the right to update the contents of this user s manual without prior notice Therefore you should thoroughly read this user s manual even if you have often purchased this product before Using this product requires technical knowledge of hardware and software Use this product only under the specified conditions such as power supply voltage temperature and humidity range Interface Corporation s products are not designed with components intended to ensure a level of reliability suitable for use under conditions that might cause serious injury or death Please consult our Technical Support Center if you intend to use our products for special purpose such as use for moving vehicles medical treatment aerospace engineering controlling nuclear power submerged translators and so on This product is made under strict quality management however when using this product for the purposes that may result in any damages lost profits or any other incidental
3. respond after Standby mode Input and output are disabled Interface Corporation 16 CBI 485220WA Index 1218 c 3 B I Basic CAN Mode nie 8 ISOTTI890832 a cotes eec tai 3 5 19 C P G w M 13 CAN DUS THO HOT a te elite 3 PEXSZ2EZOO ltda 8 CAN controller aa a ia a 5 8 POAC O TTE 3 5 CADNDIODOC OL ii uenit i tiec 3 5 PCIe vice iewer ua een 16 CAIN TRANS K airar E SN 5 Peli CAN a ars 8 Card installation enc ien 11 Pseude messase E AER 3 9 Card uninstallation eee 11 R D l A a LEA HE ATE 6 13 DOMINANT aaa 6 13 Driver software uninstallation 11 S E Signal description sss sese eee 4 SITE rM TT 3 3 Electric characteristics esses 6 Environmental specifications 14 I F Terminating resistor 13 17 Interface Corporation r For Assistance If you would like to inquire our products please contact below support interface co jp www interface co jp support Repair and Maintenance We provide repair and maintenance service for your damaged product If you need this service please refer to Repair and Maintenance of a user s manual of Japanese version and follow the procedures for repair and maintenance applications PLEASE NOTE We do not accept the repair for the product which is not used in Japan If you use our pr
4. o EIER 9 Chapter 4 External Connections eee eee e ee e 10 c Example GOnnechon ee ee 10 Chapter o Installation PR iaa 11 e Gard Installation ERI Ut 11 5 2 Driver Software Installation wz s week tc les ltda boc denned ated Ebrei ede erben ibd oret 11 So Gard UninstallatiOria se 25 fe tse cs pee ceased eH Batis A seed a cde 11 5 4 Multiple CardBus Cada 12 Chapter Cea asides lid 13 BFW EISE OF DETINIMOMNS RR Cc 13 Chapter Notes TOM USCIS nes 14 7 1 Caution Periodic Inspections and Storage occccocccccccncoccncononononnncnnnncnnnnonnnnononnncnnnncnncnnnos 14 Chapter 8 Troubleshooting sss esec 16 RO aeei M A AI SUMMAM E DE UE sie 16 Interface Corporation 2 CBI 485220WA Chapter 1 Introduction RE AM ME E 1 1 Summary The CBI 485220WA is a CAN Controller Area Network Interface card for CardBus based computers Two high speed communications channels compliant with ISO11898 2 are achieved with the SJA1000 CAN controller Royal Philips Electronics or equivalent and PCA82C250 CAN transceiver Royal Philips Electronics or equivalent The maximum bit rate is 1 Mbps Each channel provides independent communications at individually set bit rates With the large capacity FIFO buffer this card can transmit receive messages at high speed Simple operation checks of CAN bus can be performed By using the JKC 4851A the terminating resistors can be connected Packing List Part Number O CardBus Card CBI 485220W A O Ca
5. or consequential damages resulting from breakdown of this product the user is required to take adequate and appropriate measures such as installing safety devices to avoid possible serious accidents Conventions Used in This Manual A This icon denotes a warning which advises you of precautions to take to avoid injury data loss or system crash dU This icon denotes a note caution or warning Indemnification Interface Corporation makes no warranties regarding damages resulting from installation or use of this product whether hardware or software and the user assumes all risk Interface Corporation shall not be liable for any incidental or consequential damages including damages or other costs resulting from defects which might be contained in the product product supply delay or product failure even if advised of the possibility thereof Customer s right to recover damages caused by fault or negligence on the part of Interface Corporation shall be limited to the amount paid by the customer for that product This product including its software may be used only in Japan Interface Corporation cannot be responsible for the use of this product outside Japan Interface Corporation does not provide technical support service outside Japan Warranty Interface Corporation products are warranted for a period of either one year or two years from the date of shipment as evidenced by receipts or other documentation T
6. Rating CAN H CAN L input voltage Input potential difference between CAN H and CAN L 3 2 2 Recommended Operating Environment tm Mi Ma Input potential difference 3 2 3 DC Specifications CAN H output voltage 2 75 V CAN L output voltage 225 V Dominant load 45 Q Input potential difference between CAN H and CAN L S00 mV CAN H output current CAN H external voltage 5 V 105mA CAN L output current CAN H external voltage 18 V 160 mA between CAN H and CAN_L Voltage for CAN L lt 7 V i Recessive 7 V lt Voltage for CAN H LOV 40 4 V Voltage for CAN L 12 V m Input potential difference 2 V Voltage for CAN H between CAN H and CAN L Voltage for CAN L 47 V TOTUM 5 0 V Dominant 7 V Voltage for CAN H 1 0V 5 0 V Voltage for CAN L lt 12 V l Interface Corporation 6 CBI 485220WA 3 3 Circuit Diagram FPGA M M Channell a CAN controller arbitration circuit We PTT o Error status FIFO d 2 Y CAN 5 K Receive message FIFO c Sits c instan ee pu u M s op is Pseudo message transmit control O 3 T v go 3
7. ach system Please read the manual of your system 1 Do not remove this product when accessing to the external equipment Your system may not operate correctly 11 Interface Corporation CBI 485220WA 5 4 Multiple CardBus Cards When using multiple cards in one system it is required to write the CardBus ID number to the ROM in the card The CardBus ID configuration utility program in the software can configure the number Refer to Help files for more details Notes e Write the configured CardBus ID number on the back side of each card to easily confirm the number e Please download and use the newest version about software The following example shows the CardBus ID number is 0 Color seal at b Caution huela OT Pt 8 ie bere CP E HE b adoa T B pe Beira Back side of the card Interface Corporation 12 CBI 485220WA Chapter 6 Glossary A A A 6 1 List of Definitions The list below explains a selection of technical terms used in this manual perm BDefmitin CAN is an acronym for Controller Area Network standardized by ISO as a serial communications protocol CAN was developed by the German electrical equipment manufacturer BOSCH for use in automotive networks After being regulated by ISO CAN soon became the de facto standard in the automobile industry CAN technology is now used in various other fields such as factory automation agriculture medical equipment nautical c
8. ag o E O z E Transmit message FIFO gt 3 So 32 E 2 ES Z 2 S e c S O EAS 3 D niempt 4 e OSC 24 MHz S O A ERSERENR AS 2 C1 Y Same as channel 1 gt 3 een Channel 2 3 4 External Input Output Circuit The figure below shows the external input output circuit of the CBI 485220WA CBI 485220WA ae Channel 1 I 3 CAN HI Ez CAN 0 2 Transceiver EE E Z PCA82C250 y S CAN LI E a E pem Channel2 Y 3 S 8 CAN H2 CAN 0 be 25 ia Transceiver 1200 3 Z R So O PCAS2C250 6 ES H o CANI2 32 NP TEE NEE E SE E Interface Corporation CBI 485220WA 3 5 CAN Controller Access 3 5 1 Basic Mode The CBI 485220WA can directly access all registers of the SJA1000 CAN controller Moreover an interrupt request is issued for CardBus by the controller interrupt signal Basic CAN mode and Peli CAN mode are selectable e Basic CAN mode It is the mode which is compatible with the conventional PCA82C200 CAN controller Royal Philips Electronics or equivalent The contents and arrangement of a register are the same e Peli CAN mode It is the mode which added the extended function to the conventional CAN controller It has such function as 64 byte receive FIFO More advanced comm
9. ble JKC 4851A 1 1 1 Features 1 CAN protocol The CBI 485220WA can perform high speed CAN communications compliant with the CAN 2 0B protocol and ISO11898 2 This product uses the SJA1000 CAN controller Royal Philips Electronics or equivalent and PCA82C250 CAN transceiver Royal Philips Electronics or equivalent The maximum bit rate is 1 Mbps 2 One CAN controller for each channel The CBI 485220W A incorporates one CAN controller per channel Each channel provides independent communications at individually set bit rates The system clock frequency is 24 MHz 3 High performance CAN controller By adopting the SJA 1000 CAN controller the following functions are provided error code capture error count two receiver message filters and so on 4 Large capacity FIFO buffer The CBI 485220WA incorporates 64 messages for transmit FIFO and 64 messages for receive FIFO per channel This feature reduces CPU load It also allows you to transmit receive data at high speed without data loss 5 Pseudo message Pseudo messages can be transmitted By using this function a specified pseudo message can be transmitted in a fixed cycle Simple operation checks of CAN bus can be performed 6 CAN bus monitor The CBI 485220W A can monitor messages and error status which were transmitted to the CAN bus It can also confirm those timings to monitor by 10 us Moreover it can configure response messages not to output This feature helps you to monitor w
10. his warranty does not apply to the software products and expendable supplies such as batteries Note You can determine the warranty period at our Web site by the serial number of your product Those without Internet access should contact the Sales Information Center During the warranty period Interface Corporation will as a general rule replace or recondition the defective product without charge in which case the user will be required to pay the shipping costs except as set forth below The Warranty provided herein does not cover expendable supplies such as batteries and damages defects malfunctions or failures caused by impact during transportation while under owner s responsibility owner s failure to follow the instructions and the precautions contained in this manual modification and or repair of the product by other than Interface Corporation trouble caused by use with peripherals not specified by Interface Corporation power failure or surges fire earthquake tidal wave and or flood This warranty applies only when the product is used in Japan Interface Corporation warrants its repairs for six months and will again repair the same defective part without additional charge provide the product is economically repairable In that case the user should attach a copy of the most recent repair report to the repair request form If no repair report is attached it will be considered as a new repair request Before You Export Interface Pr
11. ithout loading to network 3 Interface Corporation CBI 485220WA Chapter 2 Signal Definitions 2 1 Cable Connector Pin Assignments e CNI CN2 NC Not connected Comnector catalog number 17JE 23090 02 DC2C Screw 4 40UNC 2 1 1 Signals Signal Description Signal Pin Number Direction Description CAN L 2 Input Output CAN Low tw 3 E Note Connect the cable only with the CBI 485220WA 2 1 2 Acceptable Cable Connector 9 pin D sub female connector Connector catalog number GM 9LFU Honda Tsushin Kogyo Co Ltd or equivalent Interface Corporation 4 CBI 485220WA Chapter 3 Specifications 3 1 Hardware Specifications Number of channels 2 PCA82C250 Royal Philips Electronics or equivalent CAN controller system clock frequency Transmit receive buffer 64 messages for transmit each channel memory 64 messages for receive each channel 64 records for error status each channel Maximum cable length Number of connection units 30 max 333 Vde 0 3 V 0 3 A typ Bus requirements PC Card Standards Based CardBus Environmental conditions Operating temperature 0 C to 50 C Relative humidity 20 to 90 non condensing CNI CN2 9 pin D sub male connector attached cable connection 5 Interface Corporation CBI 485220WA 3 2 Electric Characteristics This chapter shows the electric characteristics of the CBI 485220WA 3 2 1 Absolute Maximum
12. oducts The foreign exchange and foreign trade law of Japan controls the export of this product due to its possible use as a STRATEGIC MATERIAL Therefore before you export this product you must secure an export permit from the Ministry of Economy Trade and Industry of Japan CBI 485220WA Revision History March 2005 User s manual MCA E485220WA published Due to constant product improvements the information in this user s manual is subject to change without prior notice 1 Interface Corporation CBI 485220WA Contents Chapter 1 INTO nci c ER PES M MEDI Eb EU ERES CRM AIMER S ORE 3 PN Bec istant p AMONT CELERE 3 A E NU PENNE EOD RUNE 3 Chapter 2 Signal DefinitiONS cooccconcconcconoccnoocncanocanecanonanoncnnncnnos 4 2 1 Cable Connector Pin Assignments sse eee eee 4 e SIGQIIGNS pu IH A 4 2 1 2 Acceptable Cable Connector cerebro tero acid E ER e ebd ah 4 Chapter 3 SPECNCANON SE 5 3 1 Hardware Speciticationsen cata iii 5 9 2 El amp etrie GharaGlenlSliCS Goose aou ea Der ane DEM DA de 6 3 2 1 Absolute Maximum Rating ninia 6 3 2 2 Recommended Operating Environment sees eee eee eee D 92 3 DG SBOCIIICIIDEIS TTT 6 ce an 7 3 4 External Input QUIputGIrCU ei a Dedede dn Devas tia Pedes 7 3 5 CAN Controller Access cccccccccecccseeeeceeeeceececeeeeeseeeeseeessaeessaeeeseeeessucessaeesseeeseueessueessaeees 8 30 1 Basle MOJE A 8 9 5 AFIFOMOdE sh se Seas
13. oducts in other countries please contact the store where you purchased them You can download a user s manual of Japanese version from our Web site below URL www interface co jp Visit our Web site www interface co jp for Various services listed below are provided on our Web site l Product Information The latest information about our products specifications product selection guides etc Technical Support Online questions and answers rental service frequently asked questions and glossary Mail order distributors list Downloads Service User s manual software and tutorial The design and contents of the Web site are under constant review Therefore there might be some changes in its design and contents PO Ea is a trademark of Interface Corporation under application Lasa CB 1s a collective mark of Japan Electronics and Information Technology Industries Association JEITA Other product and company names are trademarks registered trademarks or servicemarks of their respective Owners O 2005 Interface Corporation All rights reserved No part of this publication may be reproduced or altered in any form or by any means without the written permission of Interface Corporation MCA E485220WA Ver 1 0 Vol 1 1
14. raft and also DeviceNet ISO11898 2 The high speed CAN communications standard The bit rate range is between 125 kbps and 1 Mbps It may not be connected to a fault tolerant CAN bus Terminating resistor The resistor used in order to minimize reflection of an electric signal also called a terminator Dominant A logical 0 is represented by the dominant bit When a dominant bit and recessive bit are output simultaneously by two different drivers on the same bus only the dominant bit is observed on the bus signal line Recessive A logical 1 is represented by the recessive bit When the bus is in the idle state a recessive bit is observed on the bus signal line 13 Interface Corporation CBI 485220WA Chapter 7 Notes for Users For your safety follow all warnings and instructions described in this manual 7 1 Caution Periodic Inspections and Storage Failure to follow this warning may result in electric shock burns serious injury and in some cases even cause death O Keep this product away from flammable gases Use this product only under the conditions as shown below Environmental Specifications Specification Temperature Range 0 C to 50 C Relative Humidity Range 20 to 90 non condensing Typical office environment Far from power source and its wiring Voltage Requirements CardBus specification 3 3 Vdc 0 3 V The following inspections should be carried out on this card periodicall
15. rminating resistor CANT CANA Note To avoid an error connect a CAN Interface with terminating resistor to the both ends of the network Interface Corporation 10 CBI 485220WA Chapter 5 Installation SS BE SURE TO ELIMINATE STATIC ELECTRICITY OF YOUR BODY BEFORE YOU INSTALL OR REMOVE THIS PRODUCT 5 1 Card Installation When you install this product in your system read the manual of your system which refers to the PC card slot 1 Make sure that the system is turned off and the power cable is unplugged This card corresponds to Hot Swap You can insert this card when the system turns on 2 Insert the card into the PC card slot in your system 2 V xu 2 Z FEL DA DS I L AS 3 Plug in the power cord and turn on the system 1 Be careful of the insert direction when you insert this product into your system to avoid system damage 1 The attached cable may interfere with the card cable connector for the adjacent slot or computer because of the connector form of the attached cable The figure below shows an example Attached cable connector PC card 2 n on A Another cable connector Computer 5 2 Driver Software Installation Refer to our Web site for the Help of each optional software when you install and use it 5 3 Card Uninstallation The method of removing PC card from your system differs depending on e
16. unications control can be performed by using the extended function Register access CardBus Interrupt CAN controller CardBus bridge circuit Control circuit Interface Corporation 8 CBI 485220WA 3 5 2 FIFO Mode In FIFO mode the following functions are provided e Transmit message FIFO or pseudo message transmit for transmit e Reseive message FIFO for receive e Error status FIFO for error control These modes require accesses to the CAN controller in the internal control Therefore direct accesses to some part of registers of the CAN controller are forbidden Register access FIFO Register access control CardBus Interrupt Interrupt circuit CAN controller CardBus bridge circuit Control circuit Notes e When using our driver software this card can be used regardless of CAN controller modes Moreover driver software cannot control CAN controller directly e When controlling this card directly without using our driver software refer to the data sheet of the SJA1000 CAN controller or I O map 9 Interface Corporation CBI 485220WA Chapter 4 External Connections 4 1 Example Connection The figure below shows example connection of the CBI 485220WA CBI 485220WA Other CAN interfaces Other CAN interfaces with terminating resistor without terminating resistor with te
17. y Periodic Inspections Cable Connections Be sure that all connectors and cables are installed correctly Connector Contacts Check for dirt or corrosion Interface Corporation 14 CBI 485220WA TO AVOID DAMAGE TO THE CARD AND POSSIBLE INJURY TAKE APPROPRIATE PRECAUTIONS AS DESCRIBED BELOW WHEN HANDLING IT Caution 1 This card should be stored exactly the same way as when it was received Proceed as follows l 2 3 4 5 Put the card back in its PC card case Wrap the PC card case with the original packing material Avoid excessive humidity Do not expose the card to the direct rays of the sun Store the card at room temperature 1 Do not modify the card Interface Corporation assumes no liability for any malfunctions resulting from users unauthorized modification of the card 1 Take measures to avoid and minimize shock vibration magnetic fields and static electricity in the storage or operating environment of this card 1 Make sure that the card 1s disconnected from the cable before inserting or removing any cards El Please keep the attached cable in a horizontal position for approximately 10 cm from the card connection part as below and fix it not to move even if stress starts The connector may be damaged if the 10N approximately 1 kgf or more loads are added its connection part Fixed CBI 485220WA Attached cable

Download Pdf Manuals

image

Related Search

CBI 485220WA

Related Contents

Toastmaster 3348/3348MEX User's Manual  Lincoln Electric 405M User's Manual  Samsung Galaxy Grand Neo GT-I9060 8GB White  13500A, Troubleshooting Flowchart  Manual de usuario Robot empujador JOR con cinta de  Samsung SGH-F310 Керівництво користувача  Mode d`emploi base de données : finaliser les propositions de  ガイドボール GP  User guide  