Home
Voice GSM Alarm System 说明书
Contents
1. EJSystem Use and Set A Connect to power initially 1 Open back cover put SIM card into SIM seats See Picture 4 Insert adapter into power hole back up battery on off button switch to ON status See picture 3 You will hear voice prompt Welcome to use voice gsm alarm system start to searching GSM signal blink every second until turn into blink every 3 seconds means GSM signal and SIM card both normal successfully If zone 6 light keep flashing and host restart every 20 seconds shows SIM card not installed or didn t work If you don t want to install SIM card or can t search signal well but you still want it used as alarm panel please shutter down GSM module host won t restart again How to Close GSM module In the disarm status press SET key for 3 seconds release it when the recording light on 2 seconds later press SET again GSM module closed when voice prompt di di di be heard Disconnect host power supply After a while restart the host Host announce di di di three times shows host switch to shutter down GSM module status How to open GSM module In the disarm status press SET for 3 seconds release it when the recording light on Wait 2seconds press SET 3 seconds once again the panel will respond with di di twice shows the GSM module is opening Disconnec host power supply then restart the host After hear welcome voice will come out di once shows host switch
2. Shenzhen ERAYELECTRONIC CO LTD Address 5th F 2 Building An le industrial Park XingHua RD Bao an zone43 Shenzhen China ERAY is registered trademark of Shenzhen ERAY ELECTRONIC CO LTD All rightreserved The first editionin 2014 General Description This Voice GSM alarm system is a multi functional smart alarm system Adopting advanced GSM digital signal process technology the system support various function of digital voice SMS self learning wireless coding remote appliance control and message recognition On site voice or SMS alert can be sent automatically to inform you with alert situation and places meanwhile six LED lights on panel show you direction too System Is reliable stable safe and easy operated It has been widely used in homes factories schools shops convenience stores financial and banking workplace cottages and residential area to protect your valuable assets Some description is illustrated with some photos for your reference but which may not consistent with the real goods Our company accepts no compensation liability for any Q technical editorial or omission errors in this guide and any accident or consequential damages arising from using this manual All information provided as is without any warranty and may change at any time without prior notice Table of Content gt 1 Features 2 System construction and usage How to use remote controller eC WS Door Sensor Installatio
3. and Coding The newly bought door sensors should be enrolled to the control panel before use For specified operation please refer to the manual of alarm system Installation finished To confirm it works properly by open your door or window with a red indicator light flashing For more information please refer to Door Windows Gap Detector User Manual Minfrared detector installation and test PIR Sensor Open detector case choose work mode When the power is on indicator bright blue light 2 seconds blue light send out wireless alarm signal Red light battery low vol replacebattery Or press code button to pair with host then put case back Choose install position adjust install angle direction walk test the protection area make sure in three steps trigger alarm Install at 2 2 2 4 meters from ground using screws to fix bracket put the detector on it Notice Indoor use only Avoid sunshine direct strong light heat stoves air condition and moving objects Don t straight at door window or vents Detect direction must be tangential with body moving direction vertical 90 degrees is the best With pets at home please adjust the detector to higher view above 0 30cm from ground in case little pet false alarm Take care of fresnel lens avoid dirty scratching falling down crashing In case damage inside components For more information please refer to Door Windows Gap Detector User Manual
4. 1 In remote phone call setting status input 56 140101 09 00 00 Method 2 Send SMS message 1234 56 14 01 01 09 00 00 to the panel Set 1 and 2 group timely arm disarm time and week Example 4 Set the first group timely arm disarm at 22 00 pm 07 00 am valid from Monday to Friday of each week Method 1 In remote phone setting status press 572200070012345 Method 2 Send SMS message 1234572200070012345 to panel Remark Disable timely arm disarm set both time to 24 00 Set 6 wireless zone type 01 06 represents 1 6 zone number iS ieDiesenrs zone lee 1 NORMAL lt STAY ARM lt lt UIN TE ENGTEIN EMERGENCY CLOSED Un Js S 0 1 represents alarming siren sound on off 0 disable 1 enable Example Set defense zone 2 as STAY arm without siren sound Method 1 In remote phone setting status input 600220 Method 2 Send SMS message 1234600220 to the panel Set 4 wired defense zone type 7 10 represents 1 4 wired alarm zone l 5 represent Zone yne 1 NORMAL STAY ARM INTELLIGENT EMERGENCY 5 CLOSED The first 0 1 represents the alarming zone siren sound on off 0 disable 1 enable The second 0 1 0 means NO short circuit to alarm 1 means NC open circuit to alarm Default NO short circuit to alarm for 07 10 defense zone JS OY SO Siren volume varies from 00 smallest to 99 largest system default 99 Note Too low volume may lead to abnormal report voice Be Cautious Al
5. anel backside Pic 2 Z9 Z10 GND COM N 12V V V C NC Spg Wire infrared detector MSupplements E How to use remote controller A short beep Confirm signal received LED Indicator s esseesae ena o PE an Exit or successfully learned Stay Home ARM 1 cial dau two short tones PENECNS ELIS SESE NE NO rr etme Disarm Built in speaker i Emergency hel Ae RE Error indication j three short tones The prompt voice of all the Voice prompt P P function and status ED OUT ARM LED Power light ARM LED Recording Lamp Defense Zone LED GSM signal LED On On Flashing quickly Flashing slowly Off Light on Light off Light on LED Light in One zone flashing LED Lightin six zones flashing Blinking every second Blinking every 3 second Panel power is normal Panel external power is disconnected using battery Alarm panel at ALL ARM state Alarm panel in STAY ARM state Changing to the DELAY ARM Alarm panel in DISARM state In recording status Exit recording Corresponding zone will alarm Delayed alarming SIM card uninstalled or without GSM signal Poor GSM signal or SIM card not installed GSM module and SIM card is working properly f Two panel installation way wall mounted and desktop Put panel on the centre of the alarm area for a best reception to the detector Keep far away from large metal objects and high frequency interference ap
6. arm panel internal speaker voice prompt on off lis on Ois off default is on Send SMS message or not lis on 0 is off Default is on Remark Back to factory setting like clear all numbers operation password 1234 but remote control and detectors code message won t lose Disconnect power turn off panel battery switch press SET while power on panel respond with beep long ringing after 5 seconds release SET button Notice Now back to factory set password 1234 Delete all remote controls and detectors coding message Syntax table 2 Only apply for SMS remote control setting and inquiry Syntax Description O Send SMS messages 12340 to panel 1 Send SMS messages 12341 to panel 2 Send SMS messages 12342 to panel 3 Send SMS messages 12343 to panel 4 Send SMS messages 12344 to panel 6 Send SMS messages 12346 to panel to query the AC power ON OFF Query phone number from Ist to 9th group 1 6 group voice alarm numbers 7 9 group 21 SMS number Note 1 voice alarm number can be SMS numbers Send SMS to 7 9 group first while alarm thencall 1 6 group numbers Query system time year month day time and Sol timely arm disarm time Query wireless wired zone status zone type ee siren on off open or short circuit alarm 80 Query customized SMS message content Note Message content default is defense zone defense alarm Modify message content from zone 1 to 9 within six words Mod
7. ify zone 10 message content 90 zone 10 message content QO in above table represent initial password If you changed password please input new one Alarm reception amp Remote Control 1 what to do when get alarm call When alarm dial the preset telephone numbers from 1 to 6 group send SMS to 1 3 group siren on off accord to your setting If one line is busy or can t get through auto dial next number every number call 3 times Get alarm call auto play 10 seconds recording without input password press cell phone telephone digital number can control following functions 1 key arm 2 key disarm 3 key listen in 4 key stop listening 5 key talk 6 key stop talking 7 key siren on 8 key siren off 9 key relay on 0 key relay off key hang up and exit won t dial next number on the list Q If you don t press or 2 continue to dial next number 2 Remote control Dial the host Ring for once and system is connected automatically Le Voice prompt please enter the password Enter your password 1234 factory default input wrong remind you input again wrong for three times hang up automatically Input right voice prompt correct password press cell phone telephone digital number can control following functions 1 key arm 2 key disarm 3 key listen in 4 key stop listening 5 key talk 6 key stop talking 8 key siren off 0 key relay off 7 key siren on 9
8. key relay on key exit and hang up key Enter Remote control make general setting refer to Sheet 1 commands Without any operation after 20 seconds auto hang up and exit 1 Listen in time is 20 seconds and for more monitoring time press 3 within 20 seconds 2 when monitoring press key 5 you can start to talk 3 while talk press 5 within 20 ontime to talk J Defense zone type and the panel parameter There are 6 wireless defense zone and 4 wired defense zones Total 10 zones Every zone with five different types 1 NORMAL Defense Zone Panel only works on ARM status No response while Disarm 2 STAY Defense zone AT HOME Defense zone While Stay Arm detectors in stay zone won t alarm even triggered for example some user install two components one is door magnet in the zone land another is infrared detector in zone 2 stay defense zone refer to Command table 1 When stay Arm people moving at home the motion sensor detected it but won t alarm if you open the door in normal zone 1 will alarm immediately 3 INTELLIGENT Defense zone if the detector in the zone triggered only once won t alarm But if triggered again within 30 seconds it will alarm immediately 4 EMERGENCY Defense zone no matter you arm disarm it will alarm immediately once detector triggered Usually pair with Smoke Detectors Gas Detectors and emergency button etc 5 CLOSED Defense zone In this zone no matter you arm disarm it
9. l Open SMS text function SIM card not read by panel SI or GSM can t call and SMS 5 902 of GSM SIM card copper chip scratched forget to preset alarm call number forget to preset SMS number balance of SIM card not enough or the validity passed Close SMS text function Can t remote control Password input wrong No record indication when alarm Coding unmatched with panel Battery low power Poor contact of Battery pieces or corroded Unmatched with panel Remote control not work Infrared detector not work Low power circuit or broken Plug line cut off Siren closed Siren no sound EACE A nearby emitter is sensor door sensor transmiting A A EA oe receiver failure Standby battery of the shortened host insufficient functions Input password or change new one or Reset Mandatory Alarm voice not recordedrecord again refer to manual book Re code Change battery Polish elastic plate of battery Contact local dealer find a matching one change battery Siren plug socket in short Repair or change plug socket Change plug line Set siren ringing time Find the interfering source and take it away Delivery back to factory Check power supply whether connected well No voice prompt from panel Closed the voice prompt Open voice prompt functions
10. mind you start to learn zone 1 Take out detector make it send out signal to panel with voice prompt coding successful If come out di sound means the detector repeat coded change another one Then press SET once again the second zone light on remind you start to learn zone 2 Take out detector make it send out signal to panel with voice prompt coding successful If come out di sound means the detector repeat coded change another one Press SET key once again to enter learn zone 3 4 5 6 status respectively Operations same as above Exit when enter learn zone 6 status press SET once again panel with di di sound and all zones lights off exit learning mode Q If some zone light on shows the zone is still under learn status 6 wireless zones can learn up to 50 different coding detectors Delete detector Delete defense zone 1 detector Press SET key twice continuously zone 1 light on press the SET 3 seconds panel with di di sound means zone 1 detector delete successfully Delete defense zone 2 detector Press SET for 3 times continuously zone 2 light one press the SET for 3 seconds again panel with di di sound means zone 2 detector delete successfully LO By analogy when you want to deleted zone 6 detector press SET for 7 times continuously zone 6 light on press SET for 3 seconds Panel with di di sound means zone 6 detectordelete successfully fJ Other function settings The sys
11. n and Test Infrared detector installation and test 3 System Use and Set 4 SMS control panel remotely 5 Alarm reception amp Remote Control 6 Defense zone type and the panel parameter 7 FQA 15 16 17 19 Features Adopt brand new quad band GSM GPRS industrial module and voice prompt easy operation mw 6 Wireless and 4 wired zones every defense zone with 5 different type closeable M2 groups timely ARM Disarm every timely ARM Disarm group can choose week 6 groups voice phone call numbers 3 groups SMS phone numbers w Embedded with multi intelligent voice prompt exactly know incidents place and defense zone while alarm m Support 10 seconds auto recording can playback on the alarm panel mw Support remote setting via your cell phone or SMS E Support remote monitoring announce functions Remote control via your cell phone or SMS to Arm Disarm etc operations E 1 group relay output realize remote home appliance control E Wireless coding compatible with 2262 amp 1527 can pair with 50 remote control and 50 detectors mw Built in NI HI rechargeable battery auto switch to back up battery and SMS alert while power cut off BSystem construction and usage Knowledge about our panel 1 6 ZONE LED _ ARM LED Panel Face picl Wire interface sise p Mi cectnestenses Back up battery switch Built in loudspeaker 4 388833338 Wire interface connection diagram P
12. oup number delete successfully Command sheet 1 all the below command valid for the two methods Preset 1 6 group voice alarm phone numbers 1 6 indicates the 1st group to the 6th group alarm numbers Please refer to Example 1 for the specific instruction Remark 1 If alarm number with extensions please input phone number extension number Press one will wait for 1 second and two for 2seconds When power cut off or power on again system will dial 6 group alarm number send SMS to 3 sms numbers panel prompt defense zone 0 alarm Delete 1 6 groups alarm phone numbers Please refer to Example 2 for the specific instruction For 1 3 groups SMS alarm numbers Specific instruction refer to Example 1 When alarm send SMS to the 3 groups numbers Delete 1 3 group SMS alarm numbers refer to Example 2 To modify the user password the default user password is 1234 Change it before using Set the delay time for out arm 0 99 seconds can be set system default 00 seconds panel ready to alarm time 0 99 seconds can be set system default 00 seconds Set siren alarm time 0 20 mins can be set system default 1 min Enable or disable alarm relay output linkage 1 is enabled and 0 is disabled the system default is 1 Set remote control voice prompt from siren on off lis on 0 is off default is 1 Set system date and time Includesyear month day hour min second Example 3 itis January 1 of 2014 9 00 00 am Method
13. pliances avoiding reinforced concrete walls and fire doors and other barriers Put it ARM when Nobody at home Press the arm key all the detectors start to work Once detector motion infrared door magnet smoke and gas etc triggered panel will alarm immediately press jbutton panel ARM led keep bright STAY HOME ARM When you are at home if you still want outdoor door window balcony detectors working but indoor sensors stop working You can press HOME ARM to sure some detectors working some not Press ip button panel ARM led keep flashing Disarm Press DISARM to stop alarm all the detectors won t trigger alarm except 24 hour emergency zone Press button ARM or STAY lights will be off Emergency call When emergency comes press SOS and it will alarm regardless of working pattern MDoor Sensor Installation and Test pic2 a Open the case install the battery properly by tear down insulation material b Clean the installation place c Install the transmitter A on the door frame and the magnet B on the door Transmitter and magnet should be on the same level and distance between them should be within 10 mm d Double sided tape or screw can be used for a firmly attachment e Make sure panel can receive wireless signal sent by detector inthe installation place A large quantity of metal and antenna should be avoided in the area of detector Testing
14. tem support make phone call send SMS for remote setting Users can realize the function via make remote phone call or sending SMS Enter phone call remote setting Use your cell phone or telephone to dial panel voice prompt enter password press 1234 initial password is 1234 Voice prompt correct password then press panel remind you Start to set Exit phone call remote setting Press first then press hang up During remote setting every number pressed will be read out by panel If you pressed once but not read or read it two times means wrong setting Please Press to exit SMS remote Settings please follow the instruction in table 1 by directly sent related massage to panel Example Set the first voice alarm number 13788889999 Method 1 In remote phone setting status input 31 13788889999 the panel with voice prompt to tell you it is succeeded And you can use following instructions in the sheet to set many features Method 2 Edit a text message 1234 31 13788889999 to the SIM card number in panel Succeed if you get panel s reply as 1 13788889999 2 3 4 5 6 7 8 9 1234 is panel password Default 1234 31 is the first group number command 13788889999 is the first alarm number Ly Example 2 If user want to delete the first alarm number Method 1 Input 31 in remote phone setting status Method 2 Text 1234314 to panel Panel will reply 1 2 3 4 5 6 7 8 9 The first gr
15. to open GSM module status General Settings Alarm message recording While alarm dial preset phone number and play already recorded message Press SET for 3 seconds panel prompt di for once record light on remind you start to record towards MIC hole on the panel Audio content should be concise such as this is XXX home residential illegal invasion here please offer help 10 seconds later the system will exit automatically For an early end you can press SET again when the recording indicator is on Add Remote Control Enter Press SET for 1 second the panel di once 6 zones lights all bright remind you start to learn remote control Then press any key of the remote control to send signal to the panel the panel respond with coding right means successfully Sounds di once means the remote control repeat coded change another remote control Exit Press SET once every 1 second total six times when all zones lights disappear exit code status Note Alarm panel can learn at most 50 different addressing remote controls Delete the remote control In learn remote control mode Press SET 3 seconds with di di sound 6 zones lights disappear same time delete all remote controls successfully Add the wireless detector Enter Press SET 1 second with di sound 6 zones lights on same time enter learn remote control mode Press SET 1 second again the first zone light on re
16. won t alarm even Detectors triggered System default Lint sero ee ee Ded a Se cee eee ei ee ee eee ee oe Sided See ene eee ic EET Integrated Alarming 1 10 defense l Linkage alarm PRaDIe l zones properties GSM Module open Siren Sound time 1 minute Audible confirmation open Delay ARM 0 for remote operation Delay alarming 0 7 10 wired zones Short circuit alarmNO 1 10 Zone alarm Siren alarm SMS Message Enable 1 10 Zone message service Panel parameters Input voltage DC9V 12V Standby currents lt 25 m A Alarm current lt 450 mA Wireless frequency 315 433 868 915MHz 2262 1 5 4 7M EV1527 300K GSM Format Support GSM850 900 1800 1900MHz option Backup battery NI HI AAA 6 DC7 2V Alarm loudness 110dB Detailed parameters The alarm is compatible with PT2262 PT2240 and EV1527 Encoding with PT2262 the 1 5M 4 7M resistance Is recommended Encoding with PT2262 300K for the resistance for data 1010 is recommended Troubleshooting Reasons Methods Not arm Put it Arm forget to preset alarm Re set numbers according call numbers i i to manual Can not dial for alarm component improperly n readjust the position installed distance too long recode again Coding not compatible SIM card unloaded Install SIM card M requires PIN code poor Cancel PIN code take to strong signal place Change another SIM card preset 1 group voice number preset 1 group SMS number pay your phone bil