Home
elektralite RGBA Dazer IP65 Manual V2
Contents
1. to the Slave dmx in Second using the Master fixture Go through the Root Menu until Set Press Enter and then use the or buttons to get to UPLD Press Enter The display will have 4 dots across the bottom The password needs to be entered The password is the following sequence using the 1 and buttons 1 press Enter once complete The upload with start immediately The upload average time for transmission is about 30 seconds While the upload is in progress the display will be flashing in YELLOW Once upload is complete and successful the word END will appear in green If there is a problem red will be the color noted Several fixtures maybe linked together in the master slave scenario and programmed simultaneously 2 REST This resets all values to their default Go through the Root Menu until Set Press Enter and then use the or buttons to get to REST Press Enter The display will have 4 dots across the bottom The password needs to be entered The password is the following sequence using the 1 and buttons 1 press Enter once complete The display will read OK followed by a return to the REST sub menu The Menu button will need pressing to return to the Root Menu Only once at the Root Menu will the dmx control function Please note the Reset also takes the dmx address back to 001 3 ID ID must be turned ON for it to work from the lighting controller So if in STAG mode you want dmx channel 11 the
2. ID to work it must be turned on in this submenu Go through the Root Menu until ID Press Enter and then use the 7 or buttons to get to either OFF or ON Once chosen press Enter to save the setting and then Menu to exit out back to the Root Menu 4 DIM The Dim function allows different Dimmer curves to be chosen There are 5 choices Choice 1 this is Dim off The Dimmer curve is 0 which means any change in dimmer level is instantaneous Choice 2 Dim 1 The dimmer curve has the shortest fade in and fade out time Choice 3 Dim 2 The dimmer curve has the 2 shortest fade in and fade out time Choice 4 Dim 3 The dimmer curve has the 3 shortest fade in and fade out time Choice 5 Dim 4 The dimmer curve has the longest fade in and the fade out time To access the DIM function go through the Root Menu until DIM is found Press Enter and then use the or buttons to get to the DIM choice required Please note the DIM function under the Set menu in the fixture does not work when in the STAG mode When is STAG mode you can operate access the DIM function directly through channel 10 on your lighting controller 5 RGBA The RGBA setting allows the ability to calibrate the white achieved when mixing RGBA When RGBA is set to OFF the output when Red Green and Blue is at maximum is 255 for all three colors By definition this combination produces a white with a blue tinge which affects all other colors if cameras and other video
3. by a qualified person and it is absolutely essential that the elektraLite RGBA Dazer IP65 be grounded So under no circumstances break off the ground pin on the Edison plug or use the fixture where a ground is not present A ground pin like the fuse for the elektraLite RGBA Dazer IP65 is there for safety Always disconnect the elektraLite RGBA Dazer IP65 from the power source when the fixture is not in use or before cleaning it ElektraLite RGBA Dazer IP65 Never pull out the Edison plug out by just pulling on the power cord itself Please keep the elektraLite RGBA Dazer IP65 away from children and the general public Please be intelligent and use common sense when operating the elektraLite RGBA Dazer IP65 3 General Guidelines ElektraLite RGBA Dazer IP65 is a lighting fixture for professional use ElektraLite RGBA Dazer IP65 should only be operated at between 120 to 240 volts ElektraLite RGBA Dazer IP65 should not be operated 24 7 24 hours a day 7 days a week elektraLite RGBA Dazer IP65 needs operation breaks to ensure that it will work for a long time without problems Please do not shake the elektraLite Dazer IP65 and avoid using brute force when installing or operating it When choosing the location to install the elektraLite RGBA Dazer IP65 please make sure that it is not exposed to extreme heat Make sure that the fixture has a good amount of free space around it for air flow Do not install it in a confined space or have insu
4. ed 2 DIM2 151 200 Nonlinear speed 3 DIM3 201 255 Nonlinear speed 4 DIM4 ARC2 S 1 0 255 MASTER DIMMER 2 0 255 RED 3 0 255 GREEN 4 0 255 BLUE 5 0 255 AMBER 6 0 255 STROBE 0 50 Linear dimmer speed DIM OFF 51 100 nonlinear speed 1 DIM1 7 101 150 nonlinear speed 2 DIM2 151 200 nonlinear speed 3 DIM3 201 255 nonlinear speed 4 DIM4 HSV 1 0 255 H hue 2 0 255 S saturation level 3 0 255 V brightness 0 50 Linear dimmer speed DIM OFF 51 100 nonlinear speed 1 DIM1 4 101 150 nonlinear speed 2 DIM2 151 200 nonlinear speed 3 DIM3 201 255 nonlinear speed 4 DIM4 17 DMX Channel Assignments 1 Grand Master for RGBA 0 255 2 RED Leds or chase speed when anyone of PRO1 thru PR10 in 8 is operational 0 255 3 GREEN Leds or cross fade time when anyone of PRO1 thru PR10 in Ch08 is operational 0 255 4 Blue Leds 0 255 5 Amber Leds 0 255 6 No effect 0 010 Snap to Red 255 011 Crossfade Red 255 000 Green 000 255 012 050 Crossfade Green 255 000 Blue 000 255 051 090 Crossfade Red 000 255 Blue 255 000 091 130 Crossfade Red 255 000 Amber 000 255 131 150 Crossfade Blue 000 255 Amber 255 000 151 170 Snap to Red 255 Green 255 Blue 255 Amber 255 171 200 Snap to White 1 approximately 3200 201 205 Snap to White 2 approximately 34009K 206 210 Snap to White 3 appro
5. equipment are keyed to this When RGBA is set to ON the output can be white balanced to whatever looks good on camera for example It also serves to balance the white into a warm white which makes people look a lot better when they are in the light See Cal 2 for how to calibrate the white when the RGBA is turned ON To turn RGBA either OFF or ON go through the Root Menu until RGBA Press Enter and then use the 7 or buttons to get to either OFF or ON Once chosen press Enter to save the setting and then Menu to exit out back to the Root Menu 6 DV The DV setting allows the ability of the leds to not flicker when using video camera The choices are NTSC or PAL NTSC is the USA system To set the DV setting go through the Root Menu until DV Press Enter and then use the 7 or buttons to get to either NTSC or PAL Once chosen press Enter to save the setting and the Menu to exit back to the Root Menu 15 KEY The Key function is an access password for the fixture The KEY can be turned OFF or ON which then deactivates or activates the password To set the KEY go through the Root Menu until KEY press Enter and use the 1 or to set the KEY to either OFF or ON If the Key is turned ON then a password is required to go into sensitive Menus and to change functions The passwordist 1 Down Up Down 16 The Personalities of the RGBA Dazer IP65 for the personality STAG please refer to the DMX channel assignments on pa
6. ersonality not defined in the tables is STAG STAG is short for STAGE and it is the full dmx number of channels as detailed in the DMX Channel Assignments shown on pages 12 and 13 The full dmx number of channels is 11 12 ID Address An elektraLite RGBA Dazer IP65 can be addressed controlled through the dmx or instead it can have its own unique ID address There are a total of 255 different ID addresses from 1 to 255 To set up the address for a fixture use the Menu button in the root menu go to ID Press Enter and then using the 1 or buttons to select the ID address Press Enter to save the address For the ID address to work you must chose a personality that uses the ID For example STAG or AR1d This allows you to access the ID address system on channel 4 Set the DMX address to d 001 for the fixture So if ID address 123 is chosen then go to channel 4 on the lighting board and set the level at 123 You will then be controlling only fixture s with ID address 123 13 Edit The Edit function allows the 10 of the inbuilt programs to be edited and customized The programs that can be edited are PRO1 through PR10 Each of the programs can have up to 99 scenes SC01 SC99 Each scene has 5 components that can be edited on the fixture They are the Red leds the Green leds the Blue leds the time the scene is played and whether the scene has a crossfade or just snaps in In the edit menu the following is the flow diagram for programmi
7. ges 12 amp 13 STAG uses all 11 channels as shown in the dmx channel assignment table ARC1 1 0 255 RED 2 0 255 GREEN 3 0 255 BLUE 0 50 Linear dimmer speed DIM OFF 51 100 nonlinear speed1 DIM1 4 101 150 nonlinear speed 2 DIM2 151 200 nonlinear speed 3 DIM3 201 255 nonlinear speed 4 DIM4 AR1D 1 0 255 MASTER DIMMER 2 0 255 RED 3 0 255 GREEN 4 0 255 BLUE 0 50 Linear dimmer speed DIM OFF 51 100 nonlinear speed 1 DIM1 5 101 150 nonlinear speed 2 DIM2 151 200 nonlinear speed 3 DIM3 201 255 nonlinear speed 4 DIM4 AR1S 1 0 255 MASTER DIMMER 2 0 255 RED 3 0 255 GREEN 4 0 255 BLUE 5 0 255 STROBE 0 50 Linear dimmer speed DIM OFF 51 100 nonlinear speed 1 DIM1 6 101 150 nonlinear speed 2 DIM2 151 200 nonlinear speed 3 DIM3 201 255 nonlinear speed 4 DIM4 ARC2 1 0 255 RED 2 0 255 GREEN 3 0 255 BLUE 4 0 255 AMBER 0 50 Linear dimmer speed DIM OFF 51 100 nonlinear speed 1 DIM 1 5 101 150 nonlinear speed 2 DIM 2 151 200 nonlinear speed 3 DIM 3 201 255 Nonlinear speed 4 DIM 4 ARC2 D 1 0 255 MASTER DIMMER 2 0 255 RED 3 0 255 GREEN 4 0 255 BLUE 5 0 255 AMBER 0 50 Linear dimmer speed DIM OFF 51 100 Nonlinear speed 1 DIM1 6 101 150 Nonlinear spe
8. immer curve 1 Shortest fade time 010 069 Dim 02 dimmer curve 2 2 Shortest fade time 070 129 Dim 03 dimmer curve 3 3 Shortest fade time 130 189 Dim 04 dimmer curve 4 Longest fade time 190 255 10 All fixtures are address 000 ID 01 through 255 correspond to dmx addresses 001 through 255 respectively 001 255 19 Cleaning and maintenance Now ignoring maintenance and cleaning is very good way of creating problems down the road and many companies and installations do just that However the net result is no matter what the fixture premature failure Changing the oil in a car most people do on a regular basis So with the fixtures regular maintenance is an excellent practice if you want the fixtures to last So what is the maintenance for the elektraLite RGBA Dazer IP65 The front glass cover for the lenses should be cleaned so the light output is maintained Use only a moist lint free cloth Never use alcohol or solvents to clean the fixture Clean the heat sink fins at the back of the fixture Finally inspect all cable REGULARLY to make sure they have no cracks in the outer sheathing 20 Technical Specification Operating voltage 100 250v Frequency 50 60 Hertz 54x high powered leds 200 VI ElektraLite is a division of Group One Group One and its divisions are constantly improving their product range and we reserve the right to make changes without prior notice Other Products Elekt
9. is attached 5 DMX 512 Control Connection and Power Connection POWER The 1018 IP65 comes with an Edison 120V connector to an outdoor water resistant connector cable Extension cables water resistant connector to water resistant connector are available as accessories DMX 512 CONTROL The 1018 IP65 come with a spin XLR connector to an outdoor waterproof 3 pin connector cable Extension cables water resistant connector to water resistant connector are available as accessories 6 Menus in the fixture Root Menu Sub Menu 1 Sub Menu 2 STAT STATIC LOOK R ED 0 255 G REEN 0 255 B LUE 0 255 A MBER 0 255 S STROBE 0 255 AUTO AUTOMATIC AT 01 THROUGH TO AT10 PR 01 THROUGH TO PR10 RUN DMX SLAV E DMX ASSIGN DMX CHANNEL 1 512 PERS PERSONALITY STAG E ARC1 AR1 D AR1S HSV ID ID 01 THROUGH 255 EDIT PRO1 SC01 THROUGH TO SC99 MAKING OWN AUTO PRO2 SC01 THROUGH TO SC99 SCENES PRO3 SC01 THROUGH TO SC99 PRO4 SC01 THROUGH TO SC99 PROS SC01 THROUGH TO SC99 PRO6 SC01 THROUGH TO SC99 PRO7 SC01 THROUGH TO SC99 PRO8 SC01 THROUGH TO SC99 PRO9 SC01 THROUGH TO SC99 PR10 SC01 THROUGH TO SC99 SET UPLD Password required See 15 KEY DV RGBA DIM ID REST RESET CAL1 WT01 THROUGH TO WT11 CAL2 RGBA KEY OFF ON 7 Static Look The elektraLite RGBA Dazer IP65 can be set to a single static look quickly Use the Menu b
10. lation around the fixture The minimum distance between the elektraLite RGBA Dazer IP65 and the illuminated surface must be more than 3 feet Always mount the elektraLite RGBA Dazer IP65 with an appropriate safety cable Operate the elektraLite RGBA Dazer IP65 only when you are familiar with the features on the fixture Do not permit operation by persons not qualified All modifications to the elektraLite RGBA Dazer IP65 will invalidate the warranty There are absolutely no exceptions If elektraLite Dazer IP65 is operated in any way different to the one described in this manual elektraLite RGBA Dazer IP65 maybe damaged and the guarantee will be void 4 Installation Please ensure that the elektraLite RGBA Dazer IP65 is hung using the appropriate C clamp or half cheeseboro A safety chain or cable should also be used as a secondary point of holding the fixture in case the clamp comes loose Never hang the fixture without a safety chain or cable If you are not qualified or have any doubts about hanging the elektraLite RGBA Dazer IP65 then do NOT hang it Do not clamp the safety cable to the U bracket or clamp That is not a secondary safety point A secondary safety point is any point that will adequately hold the elektraLite RGBA Dazer IP65 if the clamp or half cheesboro fails Then the safety cable would be the backup and stop the fixture from falling to the ground So do NOT fix the safety cable to the same place that the C clamp
11. ng EDIT PRO1 SC01 R001 R255 Red G000 G255 Green B000 B255 Blue A000 A255 Amber T000 T255 Time the scene is active 001 1 second 255 255 seconds F000 F255 Fade time for the scene 001 1 second 255 255 seconds Enter and Enter in the flow diagram above When a component is chosen for example the Red the display will automatically show the current dmx value The fixture will output the color that the RGBA is set to for that scene Use the or buttons to change the value of the output for that color Once the correct value is found for the Red for example R165 pressing Enter automatically advances to the next component which is G Green Press enter if the Green dmx value is to remain the same or use the or buttons to change This process is repeated for Blue Amber Time and Fade Pressing Menu at any time will exit out of the Edit function So if the Program is just 4 scenes long how do you stop the fixture from going ad nauseam through all 99 scenes Once the last scene is programmed then the scene following must be adjusted so all components are at 0 So R must be at ROOO G at G000 B at B000 T at T000 and finally F at F000 14 SET Set has several Sub Menus which allow functions to be used 1 UPLD Custom programs can be uploaded from a master fixture into a slave fixture First connect the fixtures to power and have a dmx cable going from the Master dmx out
12. raLED has other great products that are manufactured under the elektraLite product line Go check out the website at www myelektraLite com A preview of the products include ElektraLite ML602 ElektraLite LightStream ElektraLite DazerlP65 in white
13. raLite RGBA Dazer IP65 AT 01 to AT10 are fully pre programmed and cannot be altered PRO1 to PR10 are pre programmed and can be edited To run a program use the Menu button to get to AUTO Press ENTER Use the 1 or key to get to the program Press Enter The program will start running 9 Run Mode Run allows the fixture to operate in either DMX or Slave operation Using the Menu button in the root menu go to RUN Press Enter to get to DMX mode To get to SLAV mode use the 1 or And press enter to save this setting 10 DMX 512 Setting address Sets up the address for the dmx Using the Menu button in the root menu go to DMX Press Enter to get into DMX menu and the display will read the current dmx channel The display will read for example d 001 This means the fixture s current address is 001 To change it use the or buttons to get to the correct address Press Enter to save the dmx address The display will momentarily display the word OK and then go back to the DMX menu To exit out to the root directory use the menu button 11 Fixture Personality There are several different choices on how the fixture will operate What these Personalities do in terms of their channel assignments is detailed in the tables on pages 12 and 13 To change a Personality use the Menu button to get to PERS Press Enter then using the 1 or buttons go to the personality required Press Enter to save the Personality The one P
14. utton to get to STAT Press Enter The next screen will read ROOO This is addressing the RED leds If Red is to be in the static look then use the 1 or to increase the value of the red Numbers are expressed in DMX values so 0 is no output and 255 is highest output Press Enter to save the value The screen will automatically advance to the next color Green If Green is to be in the static look then use the 7 to crease the value of green Press Enter to save the value The screen will automatically advance to the next color Blue If Blue is to be the static look then use the 7 to crease the value of blue Press Enter to save the value The screen will automatically advance to the next color Amber If Blue is to be in the static look then use the 1 to crease the value of blue Press Enter to save the value The screen will automatically advance to the strobe function If the strobe function is to be in the static look then use the 1 to crease the value of strobes flash rate Press Enter to save the value This is the last entry and the static look is complete Pressing the Enter key just continues around if you need to make fine adjustments to the color of the static look Do not press MENU as this will get you out to the Root directory and out of the static look 8 Auto Programs The elektraLite RGBA Dazer IP65 can be set to run some inbuilt programs There are two types of programs in the elekt
15. ww 3 gt eleirrrcevitre MF ElektraLite RGBA Dazer IP65 Version 2 USER MANUAL ElektraLite a division of Group One 70 Sea Lane Farmingdale NY11735 U S A 1 631 396 0184 1 631 396 0190 WWW MYELEKTRALITE COM 1 Unpacking Thank you for choosing the elektraLite RGBA Dazer IP65 fixture For your own safety please read this manual before installing the fixture This manual covers important information on installation and applications Please keep this manual for future reference To keep this simple we are going to refer to the fixture as the elektraLite RGBA Dazer IP65 throughout the manual The elektraLite RGBA Dazer IP65 fixture uses 54 high powered leds in a balanced arrangement giving incredible output Please unpack it carefully and check whether it was damaged in shipping The following items should be in the box with the fixture Color Gel frame 2 Safety Instructions This device has left the factory in perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual The elektraLite RGBA Dazer IP65 is a high voltage fixture Be careful when dealing with high voltages Please read this manual If you do not read this manual and damages occur to the elektraLite RGBA Dazer IP65 then it could void the warranty The electric connection must carry out
16. ximately 4200 K 211 215 Snap to White 4 approximately 49009K 216 220 Snap to White 5 approximately 56009K 221 225 Snap to White 6 approximately 59009K 226 230 Snap to White 7 approximately 6500 K 231 235 Snap to White 8 approximately 72009K 236 240 Snap to White 9 approximately 8000 K 241 245 Snap to White 10 approximately 85009K 246 250 Snap to White 11 approximately 10000 K 251 255 7 Strobe effect 000 255 8 No effect function 000 040 AT 01 Automatic program 01 041 070 AT 02 Automatic program 02 071 080 AT 03 Automatic program 03 081 090 AT 04 Automatic program 04 091 100 AT 05 Automatic program 05 101 110 AT 06 Automatic program 06 111 120 AT 07 Automatic program 07 121 130 AT 08 Automatic program 08 131 140 AT 09 Automatic program 09 141 150 AT 10 Automatic program 10 151 160 PRO1 programmable Automatic program 01 161 170 PRO2 programmable Automatic program 02 171 180 PRO3 programmable Automatic program 03 181 190 18 DMX Channel Assignments Cont 8 cont PRO4 Programmable Automatic program 04 191 200 PRO5 Programmable Automatic program 05 201 210 PRO6 Programmable Automatic program 06 211 220 PRO7 Programmable Automatic program 07 221 230 PRO8 Programmable Automatic program 08 231 240 PRO9 Programmable Automatic program 09 241 250 PR10 Programmable Automatic program 09 251 255 9 Dim 00 straight line dimmer 000 009 Dim 01 d
Download Pdf Manuals
Related Search
Related Contents
ZTE R54 HSDPA Dual Band 3G Mobile Phone User Manual Kicker S10X Owner's Manual EG1150 H_2v1_it GDB-03 Demo Module User Manual Shurlube H K2 Storage System Instruction Manual Copyright © All rights reserved.