Home

5` E - Micronix

image

Contents

1. 200 100 70 MHz DIGITAL STORAGE OSCILLOSCOPE OO labview page CE jrs232 usa jan cig Summary of Features Wide selections of bandwidth 200 100 70MHz Achannels suitable for major applications in laboratories production lines or field services 1GSa s real time high sampling rate and 25k points deep memory give much detailed view into the target waveforms and maintain a high sampling rate USB host and device connection allow data storage and recalling screen image printout and remote control TFT color LCD display with wide viewing angle eliminates obscurity in any situation Signal Detection The GBS 1000 series with 1GSa s real time 25GSa s equivalent time sampling rate and 3 types of acquisition modes including normal peak detect and average picks up signals even in the most extreme cases 25k points deep memory collects more information of a given waveform providing users with further signal details 3 types of flexible triggers including edge video NTSC PAL SECAM with line selection and pulse width augment the signal capturing flexibility Complete Vertical and Horizontal Expansion Function Users via the GBS 1000 Series can either select GND or the center of the signal to execute vertical expansion Either the center of the signal or the vertical trigger point can be selected to carry out horizontal expansion A sound signal expansion selection facilitates users to expand required signals for
2. inspection Data Transfer and Printout USB host connector transfers data quickly and easily between USB flash drive and the oscilloscope which greatly expands memory via a USB The internal storage includes 4 sets of reference waveform and 20 sets of general use memory area The GBS 1000 Series handles three types of data display image bmp for viewing waveform shape and pasting into documents and presentations panel setting for saving and restoring system setup and waveform configuration csv for further analysis of signal information Printout of display Image color or grayscale is available through the PictBridge compatible Printer connected to the USB host port You can set the printout or data saving preference to allow a single press on Hardcopy during the consecutive works Setup Recovery and Transfer The last panel setting is internally stored in nonvolatile memory ready to be recovered on the next power up If the measurement environment has been frequently changed or users want to transfer the setup to another GBS 1000 Series switching between multiple system settings can be done by saving and recalling setup files using a USB flash drive When the setup gets complicated you can always recover the default system setting in a simple two step operation GBS 1000 Series FEATURES e 200 100 70 MHz Bandwidth e 4 Input Channels e 1GSa s Real Time and 25GS s Equivalent Time Sampling e 25k Points Record
3. a detailed observation of signal trigger points Measurement Functions A variety of measurement shortcuts reduce repetitive manual operations and save your precious time Autoset automatically configures the horizontal scale the vertical scale and the trigger giving an instant view of almost any signal 27 automatic measurements include voltage frequency time and delay Once the cursor function is on the measurement target will be the signal within the cursor Users can measure any desired signal based upon the application requirements The GBS 1000 Series runs and updates results of all the relevant measurements in real time You can view the results independently or together in a single display view Add subtract and multiple math operation and with 4 types of FFT FFTrms including flattop blackman hanning and rectangular are also provided DATA Log Data logger can continue monitoring input signals and storing their waveform data or image in a USB flash drive when trigger conditions are met This functionality will save users effort in tracking signals manually and allowing them to analyze and observe waveform data afterwards Go NoGo Test Function Go NoGo test function detects an user defined incoming waveform shape and can also send a signal to external devices for monitoring Program and play feature automatically runs predefined sequence and setup boosting productivity in routine measurements like production line
4. 0ms div 10s div Modes Main Window Window Zoom Roll Scan X Y Accuracy 0 01 Pre Trigger 20 div maximum Post Trigger 1000 div X Y MODE X Axis Input Channel 1 Y Axis Input Channel 2 Channel 3 Channel 4 Phase Shift 3 at 100kHz SIGNAL Real Time Sample Rate 1GSa s maximum ACQUISITION Equivalent Sample Rate 25GSa s maximum Vertical Resolution 8 Bits Record Length 25K Dots maximum Acquisition Mode Normal Peak Detect Average Peak Detection 10ns Average 2 4 8 16 32 64 128 256 CURSORS AND Voltage Measurement Vpp gt Vamp gt Vavg gt Vrms gt Vhi Vio Vmax Vmin Rise Preshoot Overshoot Fall Preshoot Overshoot MEASUREMENT Time Measurement Freq Period Rise Time Fall Time Positive Width Negative Width Duty Cycle CONTROL PANEL FUNCTION DISPLAY INTERFACE POWER SOURCE MISCELLANEOUS DIMENSIONS amp WEIGHT Delay Measurement Cursors Measurement Auto Counter Autoset Save Setup Save TFT LCD Type Display Resolution Display Graticule Display Brightness Go NoGo Output RS 232 Interface USB Line Voltage Range Multi Language Menu Online Help Data Log Time Clock 310 W x142 H x310 D mm Approx 4 3kg Eight different delay measurement Voltage difference between cursors AV Time difference between cursors AT Resolution 6 digits Accuracy 2 Signal Source All available trigger source except the Video trigger mode Automatically Adjust Vertical VOLT DIV Horizontal TIME DIV and
5. Length Maximum e 5 7 in TFT Color Display e 27 Automatic Measurements e Math Functions Including x FFT FFTrms e Multi Language Support e USB Host Support Flash Drive Storage and PictBridge compatible Printer e USB Device PC Remote Control e Data Logger Rear Panel APPLICATIONS Education Lab and Training Institution e Production Test and Quality Inspection e Repair and After Service e Circuit Design and Debugging GW INSTEK Simply Reliable SPECIFICATIONS GBS 1074 GBS 1104 GBS 1204 VERTICAL Channels 4 4 4 Bandwidth DC 70MHz 3dB DC 100MHz 3dB DC 200MHz 3dB Rise Time 5ns Approx 3 5ns Approx 1 75ns Approx Sensitivity 2mV div 5V div 1 2 5 increments Accuracy 3 x Readout 0 05 div x Volts div 0 8mV Input Coupling AC DC amp Ground Input IMQ 2 16pF Polarity Normal amp Invert Maximum Input 300V DC AC peak CATII Waveform Signal Process x FFT FFTrms Offset Range 2mV div 20mV div 0 5V 50mV div 200mV div 5V 500mV div 2V div 50V 5V div 300V Bandwidth 20MHz 3dB TRIGGER Sources CH1 CH2 CH3 CH4 Line Type Edge Video Pulse Modes Auto level Auto Normal Single Video Trigger Standard SECAM PAL NTSC Coupling AC DC LF rej HF rej Noise rej Sensitivity DC 25MHz Approx 0 5div or 5mV 25MHz 70 100 200MHz Approx 1div or 10mV HORIZONTAL Range Ins div 10s div 1 2 5 5 increments ROLL 25
6. Trigger level Up to 20 sets of measurement conditions 24 sets of waveform 5 7 inch 234 Vertically x 320 Horizontally Dots 8 x 10 divisions 8 x 12 divisions menu off Adjustable 5V Maximum 10mA TTL Open Collector Output DB 9 pin male DTE RS 232 interface USB Host Device 2 0 full speed supported AC 100V 240V 48Hz 63Hz Auto selection Available Available Available Time and Date Provide the Date Time for saved data ORDERING INFORMATION GBS 1074 70MHz 4 channel Digital Storage Oscilloscope GBS 1104 100MHz 4 channel Digital Storage Oscilloscope GBS 1204 200MHz 4 channel Digital Storage Oscilloscope Quick start guide User manual CD x 1 Power cord x 1 Probe GTP 070A 4 7OMHz 10 1 1 1 Switchable Passive Probe for GBS 1074 one per channel one per channel one per channel Probe GTP 100A 4 1OOMHz 10 1 1 1 Switchable Passive Probe for GBS 1104 Probe GTP 250A 2 250MHz 10 1 1 1 Switchable Passive Probe for GBS 1204 Specifications subject to change without notice BS 1000GD1DH GRA 405 Rack Mounting 19 4U Type GSC 005 Soft Carrying Case GTC 001 Instrument Cart 450 W x 430 D mm 120V Input Socket GTC 002 Instrument Cart 330 W x 430 D mm 120V Input Socket GTL 110 Test Lead BNC BNC Heads GTL 232 RS 232C Cable 9 pin Female to 9 pin Female Null Modem for Computer GTL 246 USB Cable USB 2 0 A B TYPE CABLE 4P FREE DOWNLOAD PC Software FreeWave software Driver USB d
7. river LabView Driver Global Headquarters GOOD WILL INSTRUMENT CO LTD No 7 1 Jhongsing Road Tucheng Dist New Taipei City 236 Taiwan T 886 2 2268 0389 F 886 2 2268 0639 E mail marketing goodwill com tw China Subsidiary GOOD WILL INSTRUMENT SUZHOU CO LTD No 521 Zhujiang Road Snd Suzhou Jiangsu 215011 China T 86 512 6661 7177 F 86 512 6661 7277 E mail marketing instek com cn Malaysia Subsidiary GOOD WILL INSTRUMENT M SDN BHD 27 Persiaran Mahsuri 1 1 Sunway Tunas 11900 Bayan Lepas Penang Malaysia T 604 6309988 F 604 6309989 E mail sales goodwill com my U S A Subsidiary INSTEK AMERICA CORP 3661 Walnut Avenue Chino CA 91710 U S A T 1 909 5918358 F 1 909 5912280 E mail sales instekamerica com Japan Subsidiary TEXIO TECHNOLOGY CORPORATION 7F Towa Fudosan Shin Yokohama Bldg 2 18 13 Shin Yokohama Kohoku ku Yokohama Kanagawa 222 0033 Japan T 81 45 620 2303 F 81 45 534 7181 E mail info texio co jp GW INSTEK Simply Reliable Korea Subsidiary GOOD WILL INSTRUMENT KOREA CO LTD 1406 Ace Hightech City B D 1Dong Mullae Dong 3Ga 55 20 Yeongduengpo Gu Seoul Korea T 82 2 3439 2205 F 82 2 3439 2207 E mail gwinstek gwinstek co kr www gwinstek com

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`utilisation Dongle Bluetooth©  BASIC mit dem Z1013  DRM User Manual  Pfister R890200 Installation Guide  安全衛生部計画課  管理運営の基準(PDF:680KB)  INSTRUCTION MANUAL (ATEX / IECEx)  

Copyright © All rights reserved.