Home

FX3S-5DM INSTALLATION MANUAL

image

Contents

1. if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN
2. JY997D51601C B MITSUBISHI ELECTRIC PROGRAMMABLE CONTROLLERS MELSEC F JAPANESE ENGLISH FX3s 5DM INSTALLATION MANUAL F X 3s This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions Store this manual in a safe place so that it can be taken out and read whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Manual Number JY997D51601 Effective April 2015 Specifications are subject to change without notice 2014 MITSUBISHI ELECTRIC CORPORATION Safety Precaution Read these precautions before use This manual classifies the safety precautions into two categories AAWARNING and CAUTION Indicates that incorrect handling may cause hazardous Z WARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on the circumstances procedures indicated by CAUTION may also cause severe injury It is important to follow all precautions for personal safety Associate
3. N e Please contact a certified electronic waste disposal environmentally safe recycling and disposal of your device company for the TRANSPORTATOION AND STORAGE PRECAUTIONS CAUTION e The product is a precision instrument During transportation avoid impacts larger than those specified in the general specifications by using dedicated packaging boxes and shock absorbing palettes Failure to do so may cause failures in the product After transportation verify operation of the product and check for damage of the mounting part etc 3 1 Applicable PLC Model name Applicability FX3S Series PLC e Only one display module can be used per main unit Ver 1 20 or later For details on the system configuration refer to the following manual FX3s Series User s Manual Hardware Edition 3 2 General Specifications The general specifications are equivalent to the PLC main unit For general specifications refer to the following manuals FX3S Series User s Manual Hardware Edition 3 3 Display Specifications Item Specifications Display device TN monochrome liquid crystal display Display character Backlight Button Seven segment display icon display Green LED backlight 4 operation buttons ESC and OK 4 Function List The functions of a display module are listed as follows For details on the functions refer to the following manuals FX3s Series User s Manual Hardware Edition e Monitor T
4. d Manuals Manual name Description Explains the FX3S Series PLC specifications for I O wiring installation and maintenance FX3S Series JY997D48601 User s Manual Hardware Edition MODEL CODE O09R535 How to obtain manuals For product manuals or documents consult with the Mitsubishi Electric dealer from who you purchased your product Applicable standards FX3S 5DM comply with the EC Directive EMC Directive Further information can be found in the following manual FX3S Series User s Manual Hardware Edition Attention e This product is designed for use in industrial applications Note e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany 1 Outline The FX3S 5DM display module hereinafter called display module is installed to the FX3S Series main unit or expansion board to monitor change device states and values 1 1 Incorporated Items Product FX3S 5DM display module Included items _ Installation Manual This manual 1 2 External Dimensions and Part Names 5 Unit mm inches ELECTRIC i FX3s 5DM MITSUBISHI Cut off this part when 1 lt using an expansion board at the same time e 9 6 0 38 MASS Weight Approx 20 g 0 05 Ibs No 1 OK button 2 button 3 button 4 ESC button 5 Display Description Use to choose the item set the va
5. est e Clock display and setting e Operation button ON OFF information e Display screen protect function e Specified device monitor function e Back light off function e Error display valid invalid e Decimal hexadecimal current value display setting This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur
6. lue etc Use to move cursor or set the value Use to move cursor or set the value Use to cancel operation or return to previous screen Displays current time and monitored status of device Connector for 6 Used to connect display module to PLC Display module fixing hook Used to fix display module to PLC When used together with an expansion board 7 2 Installation INSTALLATION PRECAUTIONS WARNING e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product INSTALLATION PRECAUTIONS CAUTION Use the product within the generic environment specifications described in PLC main unit manual Hardware Edition Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it high to temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur Do not touch the conductive parts of the product directly Doing so may cause device failures or malfunctions Connect the display module securely to the appropriate connector Loose connections may cause malfunctions The following section describes the installation method for the FX3S Series PLC FX3S 30ML In this example Tu
7. rn off the power to the PLC before installation For more details on removal and installation refer to the PLC main unit manual FX3S Series User s Manual Hardware Edition A 2 1 When Installing the Display Module Directly to the Main Unit 1 Remove the top cover A in the figure on the right 2 Make sure the display module B in the figure on the right is in parallel with the main unit and attach it to the optional equipment connector 2 2 When Using the Display Module Together with an Expansion Board Assuming that the expansion board is attached to the main unit The connector cover for the expansion board is removed To attachment of the expansion board refer to the following manual FX3S Series User s Manual Hardware Edition 1 Cut off part A shown in the right figure display module Caution When part A is cut off the display module can not be installed to the main unit directly 2 Make sure the display module is in parallel with the main unit and attach it to the optional equipment connector B in the figure on the right 3 Specifications STARTUP AND MAINTENANCE PRECAUTIONS CAUTION e Do not disassemble or modify the PLC Doing so may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric representative e Do not drop the product or exert strong impact to it Doing so may cause damage DISPOSAL PRECAUTIONS CAUTIO

Download Pdf Manuals

image

Related Search

Related Contents

販売名:鼓膜センサーTM400  Phoenix Audio Quattro3  Global Water User`s Manual - Global Water Instrumentation, Inc.  Projector 8420 / 8421 User Manual  Full HD Speed Dome IP Camera User Manual  10F01 BIJSLUITER: INFORMATIE VOOR DE  drp-1 digital rackmount recorder  SAVINGDA 取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file