Home

NITGEN® EvTools User Manual

image

Contents

1. 22 z 22 2222022 2000nan0000nnn0nnnnnunnnnnunnnnnnnnnnnunnnnnnnnnnn 40 NITGEN Products 5 EvTools User Manual In NITGEN NITGEN EvTools System environment System requirements Windows 98 Windows NT Windows 2000 Windows XP Target Device FDA12 FIM10 HV FIM10 LV FIMO1 Communication COM port The specification of serial cable Target Board Type of Cable Sin F T9 pin M direct pe FIM10 9 pin F 9 pin F cross type FIMO1 9 pin F 9 pin F cross type NITGEN Products 6 EvTools User Manual NITGEN EvTools fse MIGEN 1 How to Connect 1 1 About the Evaluation Program NITGEN FOAFIM EvTools File View Jools Help a TI SE Menu CHANGE DELETE Basic YERIFT Operation IBENTIET Button GET MINUTIAE INSTANT MATER INSTANT SERTE INSTANT IDENTIKE CAPTURE Continuous Capture STATUS Target Devi SUCCESS Fall CANCEL arget Device Inforhation i z Information of Devise Type FIMOL Serial Port COM1 Firmware Version 0 00 Baud Rate 115200bps User Count O Protochl General FDA12 FIM10 FINAN1 Status Window Fingerprint Image Continuous Display Window Capture Figure 1 Main window of the Evaluation Program The evaluation program EvTools which is shown above is mainly designed to test and evaluate functions of FDA12 FIM10 and FIMO1 The initial display is composed of an image window for fingerprint
2. ll Eine Figure 3 The messages window for establishing the connection of serial communication 1 3 Serial Communication Set Up In the EvTools you can change baud rate you want Firstly select File gt Serial Comm to display the configuration window shown in Figure 4 Then change baud rate to the new value and click SET BAUD RATE button The default baud rate of device is 9 600 bps serial Communication x Setup Information Baud Rate 57600 E Port com SET COM PORT Figure 4 Serial communication configuration window If all procedures are successfully done the message window shown in Figure 5 is displayed Figure 5 Success message window for changing baud rate For a communication with a new baud rate try to connect again by clicking the CONNECT button In FDA12 and FIM10 both device and EvTools s baud rate are changed by this function But NITGEN Products 9 EvTools User Manual NITGEN EvTools In NITGEN in FIMO1 Only EvTools s baud rate is changed The baud rate of FIMO1 can be changed in the system configuration window Refer to Appendix A NITGEN Products 10 EvTools User Manual NITGEN EvTools he deal 2 Operation of Basic Functions 2 1 Master Mode e NITGEN FDA FIM EvToo s AE File View Tools Help ENTER MASTER EMF LIL CHANGE CELETE VERIFY IDENTIFY GET MINUTIAE INSTANT MATCHING INSTANT VERIFY INSTAN
3. NITGEN FOAFIM EvTools ES File View Tools Help CHANGE DELETE VERIFY IDENTIFY GET MINUTIAE INSTANT MATCHING INSTANT VERIFY INSTANT IDENTIFY Continuous Capture START STATUS Success Fail CANCEL Information Device Type FIMOL Serial Port COM Firmware Version 0 48 Baud Rate 115200bps User Count 3 Protocol General EE A Figure 10 Message for FP registration After the first FP registration is done successfully the below message window Figure 11 shows up At this moment take your finger off sensor and then put the same finger on the sensor again for the second FP registration Lift your fingertip Figure 11 Message window for the success of the first FP registration NITGEN Products 14 EvTools User Manual f ITGEN NITGEN EvTools 66 wv G If the second FP is identical to the first FP enrollment procedure is done successfully and the message window Figure 12 shows up However if the enrollment is failed the message window Figure 13 shows up Figure 13 Failure message window of enrollment 2 3 Deletion This paragraph explains the procedure of deleting a user record After clicking the DELETE button in master mode the window what requests fingerprint ID shows up Type ID to be deleted and then clicks OK After the procedure of deletion is done successfully the message window Figure 14 shows up On the other hand if there e
4. Initial packet trace window The packet trace window displays received transmitted packets according to every command and acknowledge NITGEN Products 35 EvTools User Manual In NITGEN NITGEN EvTools Packet Trace Figure 52 Packet trace window to display packets 3 11 Power On Off By using a power down function FDA12 can be powered off Click the Power Off button and then EvToolsTM powers off FDA12 via RTS signal line of RS232 The appearance of this button is changed according to power status of FDA12 When FDA12 is powered on the appearance of the button is Power Off When powered off the appearance of the button is changed to Power On This function is only supported in FDA12 3 12 Upgrade Firmware Programs stored in the flash memory of device can be quickly and easily upgraded using this function From windows menu bar select Tools gt Upgrade Firmware and then dialog window for opening firmware file pops up Select a firmware file for upgrade and then the upgrade is proceeding with processing bar window Figure 53 Firmware file format of FDA12 is Intel hex hex and firmware file format of FIM10 and FIMO1 is binary bin WARNING DONT STOP THIS PROCESS Figure 53 Processing bar window NITGEN Products 36 EvTools User Manual f NITGEN NITGEN EvTools d G When firmware upgrading completes success message window Figure 54 pops up Figure 54 Success
5. NITGEN EvTools In NITGEN checked and save it as a file If you select To get full records and then click OK button in the window all user records registered are downloaded as files Each file name is same as user ID The structure of DB is described in NITGEN CommProtocol document This function is only supported in FIMO1 3 2 9 OPEN This function is used to update user records extracted through DOWNLOAD function and display its information in EvTools Click the OPEN button and then dialog window like Figure 37 is displayed in host tab window of database manager as shown in Figure 36 DB Manager E BS E EN Device Host Select All ee E Pp e STATUS CHECK CANCEL 4 D CLOSE Figure 36 Host tab window of database manager NITGEN Products 27 EvTools User Manual NITGEN EvTools h MIGEN Files of type Record Files rec Cancel Open as read only E Figure 37 Dialog window for opening user record Choose user record files you want to update and user records are updated and then the update information is displayed as shown in Figure 38 DE Manager NES xx Device Host FP Select All ID AUTHORITY TIME O 1111 USER 2004 01 01 02 mee O 0003 USER 2004 01 01 02 7 g 0004 USER 2004 01 01 02 CLEAR O 0005 USER 2004 01 01 O2 O 0007 USER 2004 01 01 O2 O 0008 USER 2004 01 01 02 O 0009 USER 2004 01 01 O2 O
6. amp SAVE LOG DATA Firstly select View gt Log Data and then the log data window Figure 40 pops up Click the READ amp SAVE LOG DATA button and then click OK button in the window Figure 41 Input file name in the dialog window shown in Figure 29 Ey Tools 4 x 2 save the log data as file Noth Figure 41 Message window to confirm saving log data 3 3 2 DELETE ALL LOG DATA This function is used to delete all log data in FIMO1 After clicking the DELETE ALL LOG DATA button Click OK button in the message window shown in Figure 42 EvToals E E xl AN Are you sure to delete all log data Figure 42 Message window to confirm deleting all log data NITGEN Products 30 EvTools User Manual In NITGEN NITGEN EvTools This function is only supported in FIMO1 3 4 User Data FDA12 FIM10 and FIMO1 have pre allocated non volatile memory for user application specific purpose It is possible to write read application specific data at this memory It s so called user data You can write one byte by one byte and read several bytes at one time User Data x Read User Data Address Size Data hex Write User Data Address lo WRITE USER CATA SIZE o Data hex ERASE USER DATA BLOCK CLOSE Figure 43 User data window User data size is different according to devices FDA12 FIM10 LV FIM10 HV FIMOT etc 3 5 Device Pa
7. EvTools User Manual f ITGEN NITGEN EvTools Mn G message window shown in Figure 21 is displayed If both first minutiae and second minutiae are extracted from other fingerprint or first minutiae and second minutiae are identical warning message box shown in Figure 13 is displayed Open TE Look in E Test Minutiae e pr EZ Files of type MIN files min Cancel Open as read only Figure 22 Success message window for changing fingerprint minutiae 2 4 4 Change Minutiae from Sensor After selecting the Change Minutiae from Sensor and clicking the OK button the request window for FP ID shown in Figure 8 is displayed Next procedure is the same as enrollment in FDA12 2 5 1 1 Matching Verification This paragraph explains the procedure of verification using FP ID The VERIFY button is used to compare minutiae extracted from the captured FP with enrolled minutiae that have the same ID After clicking the VERIFY button the request window for FP ID NITGEN Products 18 EvTools User Manual f ITGEN NITGEN EvTools in G pops up Types ID to be matched and then place finger on the sensor If the 1 1 matching called Verification is done successfully the success message window Figure 23 pops up Otherwise the failure message window Figure 24 pops up xi Verification succeeded Figure 24 Failure message for the 1 1 matching If the wrong ID is incid
8. HY IV Using Latent SET _ E SAWE SYSINFO Using Adaptive Capture SET GET SYSTEM INFORMATION CLOSE FDA12 amp FIM10 FIMO1 Figure 32 System configuration window In master mode select View gt System Information menu The sub window shown in Figure 32 is displayed After changing each parameter value click each SET button to make changed parameter effective You can see current parameter values with GET SYSTEM INFORMATION or GET SYSINFO button SAVE SYSINFO button is only included in system configuration window for FIMO1 This button is used to save current system configuration of RAM in flash memory FIMO1 need this function because of difference in option setup method In FDA12 or FIM10 Set functions make change parameter in not only RAM but also flash memory But Set functions make change parameter only in RAM in FIMO1 Consequently FIMO1 is reset then changed information is disappeared So this button is needed System option is different according to devices FDA12 FIM10 LV FIM10 HV FIMO1 etc NITGEN EvTools User Manual Products 24 In NITGEN NITGEN EvTools 3 2 Database Manager The manipulation of DB is possible through DB Manager window in master mode DB Manager s x DB Manager Device Host IT Select All AUTHORITY ID AUTHORITY GET FINGERPRINT LIST DOWNLOAD DELETE RECORD DELETE ALL RECORD DELETE ALL USER DE
9. 0010 USER 2004 01 01 02 O 0002 USER 2004 01 01 02 STATUS CHECK CANCEL 4 D CLOSE Figure 38 Window after updating user data This function is only supported in FIMO1 NITGEN Products 28 EvTools User Manual In NITGEN NITGEN EvTools 3 2 10 UPLOAD This function is used to add user records are updated in EvTools to FIMO1 After checking check box of ID for uploading to FIMO1 click this button and then user records are added to FIMO1 within affordable limit EvToals Figure 39 Success message for uploading data This function is only supported in FIMO1 3 2 11 CLEAR This function is used to delete data of user records updated in EvTools EvTools Click this button then all data updated are deleted and list box of host tab is initialized This function is only supported in FIMO1 3 3 Saving Log Data This paragraph explains how to save log date as a log file Prior to saving log data it should be master mode and Log Enable of system configuration should be chosen NITGEN Products 29 EvTools User Manual In NITGEN NITGEN EvTools Log Data e Nth previous log M fo Oldest unread log Last written log Call log C From oldest unread to last DELETE ALL LOG DATA STATUS CANCEL CLOSE Figure 40 The window to save log data Log structure is different according to devices FDA12 FIM10 LV FIM10 HV FIMO1 etc 3 3 1 READ
10. ENTIFY CAPTURE STATUS CANCEL DISCONNECT Figure 31 Continuous capture During continuous capture Success value indicates how many images are captured successfully And Fail indicates how many errors occur Click the STOP button to stop capture NITGEN EvTools User Manual Products 23 In NITGEN NITGEN EvTools 3 Operation of Additional Functions 3 1 System Configuration You can change the device configuration such as image sensor security level capture latent relay wiegand and log option in master mode system Information FIMO1 System Information x m Image Option Image Sensor Option Wiegand Option Gain f2 Gain 2 SH Protocol Format 26bit SET Brightness Jao f ja Brightness 40 tT Site Code jo SET Contrast 20 Contrast 20 tT Relay Option z i SET m Security Level m Security Level Bere ser Verification E SET SECURITY LEVEL Verification E SCH Unit 100msec SET Identification la Identification E SCH Serial Option Capture Option Using Channeli EA Capture Period E SET CAPTURE PERIOD e Register Quality 40 SET ChannelO 115200 y SET IV Latent Option SET LATENT OPTION Verify Quality 30 SET Channeli 9600 DI SEN Log Enable SET LOG OPTION Capture Period Bo SET E Using Log SET Set Default Option Unit 100msec i SET DEFAULT OPTION ee Device Type FIM1O
11. FP display information box for system information and a few buttons for NITGEN 0 Products 7 EvTools User Manual NITGEN EvTools h MIGEN a specific function And it is possible to set get hardware configuration like baud rate of serial communication RS232 and manage FP database DB in the EvTools 1 2 Initial Connection After executing FIM _EvTools exe you can communicate with the target device NITGEN FOA FIM EyTools E 10 x File View Tools Help Open Image serial Comm EMR GLL FO 412 Select Protocol Crow CHASE sn FMIN ae ate FIMATU LY e FIMO IDENTIFY GET MINUTIAE INSTANT MATNZHLNG INSTANT SERTE INSTANT IDENTIE CAPTURE Continuous Capture START STATUS SUCCESS Fail Information Device Type FIMOL Serial Port COMI Firmware Version 0 00 Baud Rate 115200bps CANEEL User Count 0 Protocol General MMM Figure 2 The selection of target device For connection you should select target device type by selecting File gt Select Board gt FDA12 FIM10 FIMO1 after checking a serial cable and power line are correctly connected And then click CONNECT button If the connection is successfully made a success message shown in NITGEN Products 8 EvTools User Manual f NITGEN NITGEN EvTools d G Figure 3 pops up Otherwise a failure message pops up The Initial baud of serial communication is set to 9 600 bps by default
12. ITGEN EvTools 2 11 Fingerprint Capture 2 11 1 Capture The image captured through the sensor can be seen by this function After clicking the CAPTURE button place FP on the sensor The captured FP is displayed at FP image display window inside main window If you want to save captured FP select File gt Save Image As Then the dialog window Figure 30 pops up Type the name of the image file to save Ev Tools currently supports only raw image data The stored FP image can be seen again at FP image display window by selecting File gt Open Image Saveas a Savein Y Test e Ae ES Save az type Raw Dez raw Cancel Figure 30 Dialog window for saving FP image as a file E 2 11 2 Continuous Capture This function is used to continuously capture FP through the sensor and display it After checking the Continuous Capture box and clicking the START button place FP on the sensor The following Figure 31 shows the main window doing continuous capture NITGEN Products 22 EvTools User Manual NITGEN EvTools MITGEN FOA FIM EvTools In NITGEN File View Tools Help W Continuous Capture Success 0 Fail Information Device Type FIMOL Firmware Version 0 48 User Count 4000 Capture 6 packet Serial Port COM1 Baud Rate 1152D0bps Protocol General CHANGE MELTE VERIFY IDENTIFY GET MINUTIAE INSTANT MATCHING INSTANT VERIFY INSTANT ID
13. In NITGEN NITGEN EvTools NITGEN EvTools Evaluation Program for Stand Alone Fingerprint Recognition Device User Manual For FDA12 FIM10 and FIMO1 Version 1 05 NAC Rroducte 1 EvTools User Manual NITGEN EvTools Copyright 1998 2004 NITGEN Co Ltd ALL RIGHTS RESERVED Serial Number Specifications can be changed without notice NITGEN EvTools User Manual In NITGEN Products 2 In NITGEN NITGEN EvTools Revision History zo vesn Gees une 2008 o9 Priminayverson L L_ February 3 2004 Minor misprint fixed June 28 2004 Functions of FIMO1 are added NITGEN Products 3 EvTools User Manual In NITGEN NITGEN EvTools Contents HOW TO CONNEC f nee es ee einen 7 1 1 ABOUT THE EVALUATION PROGRAM snssssnnnssserrrinssrerrrnnnssrrrnnnesrrrnnnssrrrnnnesrerrrnnnessrrrrrnrererrnn 7 1 2 INITIAL CONNECTION Eau nina 8 1 3 SERIAL COMMUNICATION GET Up REENEN EEN En 9 2 OPERATION OF BASIC FUNCTIONS 22 22220202220000n000nnn00nnnnnunnnnnunnnnnunnnnnunnnnnnnnnnnnnnnnn 11 DI RST ICD be santa irc 11 22 ENROLMEN eee 12 23 DEE TON ee ae Reese 15 A e O A 15 2 4 1 Change Master Privilege amp Gave 16 2 4 2 Change Password amp SAQVC oooononncccnnccccocconooonncnonnonononononncnnnnnnnnnonnononannnnnnnnnnnnnonnnnnnazennos 17 2 4 3 Change Minutiae from Host 17 2 4 4 Change Minutiae from Sensor ccoccccccccccocconococononononononoconnnnnnnnnnnonnannnnnnnnnnnn
14. LETE ALL MASTER SET MASTER RESET MASTER STATUS CHECK CANCEL CLOSE DOWNLOAD DELETE RECORD DELETE ALL RECORD DELETE ALL USER DELETE ALL MASTER SET MASTER RESET MASTER STATUS CHECK CANCEL CLOSE FDA12 amp FIM10 FIMO1 Figure 33 Database Manager Window 3 2 1 GET FINGERPRINT LIST All enrolled user IDs and master IDs are displayed like Figure 34 The one column is user ID and the other column is authority field for a master indication Normal user ID doesn t have any mark in authority field By clicking GET FINGERPIRNT LIST user lists are displayed DB Manager y E em E Device Host Device Host F Select All I Select All AUTHORITY MASTER AUTHORITY GET FINGERPRINT LIST O 0001 MASTER DOWNLOAD 0002 0003 0004 DELETE RECORD 0005 DELETE ALL RECORD cone ao DELETE ALL USER 0007 0008 DELETE ALL MASTER 0009 0010 SET MASTER RESET MASTER STATUS CHECK CANCEL CLOSE 0002 0003 MASTER 0004 Docs DELETE RECORD 0006 DELETE ALL RECORD 0007 0008 DELETE ALL USER 0009 0010 DELETE ALL MASTER SET MASTER RESET MASTER STATUS CHECK CANCEL CLOSE oom0000000 FDA12 amp FIM10 FIMO1 Figure 34 The DB manager window after getting fingerprint lists 3 2 2 DELETE RECORD In FDA12 or FIM10 a user can be deleted by clicking DELETE RECORD button after selecting an ID to be deleted NITGEN Pr
15. T IDENTIFY CAPTURE Continuous Capture START STATUS SUCCESS Fail CANCEL Information Device Type FIMOL Serial Port COM Firmware Version 0 48 Baud Rate 115200bps User Count 3 Protocol General DISCONNECT Figure 6 Main window after connection The Main window configuration is different between device types After connecting most of all buttons get activated as shown in Figure 6 But several buttons like ENROLL still are not enabled by the reason that these functions should be done by masters The device doesn t have any registered user initially So first of all you should register the first master FP after changing to master mode by clicking the ENTER MASTER MODE button NITGEN Products 11 EvTools User Manual NITGEN EvTools be MIGEN In the master mode it is possible to add delete user convert user privilege normal master and create delete password for user and device In FIMO1 it is possible to change user FP and password too If masters or device password were registered in device the device asks master authentication with FP password or device password to change into master mode lt will be explained later at section 3 2 4 and 3 5 e NITGEN FDA FIM EvTools oj xj File View Tools Help ENROLL CHANGE DELETE VERIFY IDENTIFY GET MINUTIAE INSTANT MATCHING INSTANT VERIFY INSTANT IDENTIFY Continuous Capture START STATUS SUCCESS Fai
16. ant Verify The Instant Verify is used to compare the minutiae stored outside the device with the minutiae stored inside the device NITGEN Products 20 EvTools User Manual f NITGEN NITGEN EvTools dh G After clicking the INSTANT VERIFY button request window for FP ID is displayed and then type ID to be compared Subsequently dialog window for opening minutiae file pops up and then you choose it Next procedure is same as verification This function is only supported in FIMO1 2 9 Instant Identify The Instant Identify is used to compare the minutiae stored outside the device with the minutiae in DB of the device After clicking the INSTANT IDENTIFY button dialog window for opening minutiae file pops up and then you choose it Next procedure is same as identification This function is only supported in FIMO1 2 10 Get Minutiae The Get Minutiae is used to save minutiae data as a file from the captured FP After clicking the GET MINUTIAE button place finger on the sensor The dialog window for saving minutiae as a file Figure 29 pops up Type the name of the minutiae file to save This function is available at the FDA12 firmware V1 1 or later FIM10 series and FIMO1 EA a Save in y Test Minutiae e Ee a D001 min Save as type MIN files min Cancel E Figure 29 Dialog window for saving minutiae as a file NITGEN Products 21 EvTools User Manual In NITGEN N
17. e is changed successfully message window shown in Figure 17 pops up EvTools x To change privilege succeeded Figure 17 Success message window for changing privilege NITGEN Products 16 EvTools User Manual In NITGEN NITGEN EvTools Ev Tools Figure 18 Warning message window for wrong ID 2 4 2 Change Password amp Save After selecting the Change Password amp Save and clicking the OK button the request window for FP ID and password shown in Figure 19 is displayed Type ID to be changed password and a new password and then click the OK button If the password is changed successfully message window shown in Figure 20 pops up Input Fingerprint ID amp Passware x Fingerprint ID Kee ID Password Figure 20 Success message window for changing password 2 4 3 Change Minutiae from Host After selecting the Change Minutiae from Host and clicking the OK button the request window for FP ID shown in Figure 19 is displayed Type ID to be changed minutiae and click the OK button and then dialog window for opening minutiae file pops up like the following Figure 21 First of all you should choose minutiae file yon want to change and the dialog window pops up again and then you choose other minutiae file that was extracted from same FP If both first minutiae and second minutiae are extracted from same fingerprint success NITGEN Products 17
18. entally entered click the CANCEL button to terminate the procedure of verification In this case the cancel message window Figure 25 pops up x AN Verification canceled Figure 25 Cancel message for the 1 1 matching 2 6 1 N Matching Identification This paragraph explains the procedure of identification without using FP ID The IDENTIFY button is used to compare minutiae extracted from the captured FP with all FP minutiae in DB of the device After clicking the IDENTIFY button place finger on the sensor If the identical FP is founded through the 1 N matching called Identification the success message window Figure 26 pops up On the other hand if the identical FP is not founded the failure message window Figure 27 pops up NITGEN Products 19 EvTools User Manual In NITGEN NITGEN EvTools Figure 27 Failure message for the 1 N matching Also identification procedure can be canceled by clicking the CANCEL button and then the cancel message window Figure 28 pops up Figure 28 Failure message for 1 N recognition 2 7 Instant Matching The Instant Matching is used to compare the minutiae stored outside the device with minutiae extracted from the captured FP After clicking the INSTANT MATCHING button dialog window for opening minutiae file as shown in Figure 21 pops up Choose minutiae file you want to match then place finger on the sensor 2 8 Inst
19. l CANCEL Information Device Type FIMOL Serial Port COM Firmware Version 0 48 Baud Rate 115200bps User Count 3 Protocol General SISNET Enter master mode is succeeded Figure 7 Main window in master mode 2 2 Enrollment This paragraph explains the procedure of enrolling a new user After clicking the ENROLL button in master mode the request window for FP ID and password shown in Figure 8 is NITGEN Products 12 EvTools User Manual In NITGEN NITGEN EvTools displayed for each device Register Fingerprint q xl Fingerprint ID 123456789 Password Input Fingerprint ID q X TT Fingerprint ID Ge User Master Cancel m FDA12 FIM10 amp FIMO1 Figure 8 Request window for fingerprint ID and password The FP ID is possible up to 9 digits in FDA12 and FIM10 and is possible up to 10 digits in FIMO1 Optionally the password is possible up to 15 digits and the selection of master privilege is possible in FIM10 and FIMO1 EvTools Figure 9 Warning message window for existence of the same ID The new ID should be unique and different from all enrolled IDs If the same ID exists warning message window shown in Figure 9 is displayed and the enrollment procedure gets terminated If new ID is enrolled successfully success message is displayed as shown in Figure 10 and then goes to the next step NITGEN Products 13 EvTools User Manual NITGEN EvTools be MIGEN
20. message window for upgrading firmware NITGEN e Rroducte 37 EvTools User Manual NITGEN EvTools he delta Appendix A Serial Communication Set Up in FIMO1 In this chapter how to change baud rate of FIMO1 and EvTools is explained 1 The Change of Baud rate of FIMO1 In master mode select View gt System Information menu to display system configuration window Then change baud rate of channel you want to the new value and click SET button If all procedures are successfully done the message window shown in Figure 55 is displayed Figure 55 Success message window for changing baud rate of FIMO1 GET SYSINFO and SAVE SYSINFO button are inactivated FIMO System Information Image Sensor Option Gain Brightness Contrast Security Level Verification Identification Capture Option Register Quality 40 SET verify Quality Capture Period Unit 100msec MW Using Latent Using Adaptive Capture Wiegand Option Protocol Format 26bit Site Code fo SET MEA SET MEA Relay Option Using Relay Relay Time Unit pose RR Serial Option Using Channeli SE ChannelD EE Channel aen wt Using Log SS jer User Capacity 4000 GET sr sinha SARE ST INF CLOSE Figure 56 System configuration window after changing baud rate of FIMO1 In this status only the baud
21. nonnnnnnanonnos 18 RER A Lelleg Ter le OR 18 2 6 1 N MATCHING IDENTIFICATION ans 19 2 7 INSTANT MATCHING aa 20 EA TT VER a E A E E ee 20 2 9 INSTANT IDENTIFY ee ae ae een 21 2 TOGET HEEN 21 2 TT PINGERPRING CAPTURE cacao 22 2 11 1 Capture 22 2 11 2 COMMAUOUS CADUTE iaa 22 3 OPERATION OF ADDITIONAL FUNCTIONS 222 422222022020000002nnn00nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 24 3 1 SYSTEM CONFIGURATION eege 24 EEGENEN 25 Oe te GEIL PINGERPRAINT LIST an a i 25 BE DELETE RECON O ratios ee een seem 25 NITGEN Products 4 EvTools User Manual In NITGEN NITGEN EvTools 32 3 DELE TE ALL RECORD anne einen ee 26 E ETA EE 26 320 RAEE MASTER EE 26 326 DEEETE ALE USE ee 26 32 7 DELETE ALE MASTER 2 iaa 26 928 I VIN OF a eos 26 TEILEN ee 27 Se 10 UPLOAD rent o 29 TEEN anal 29 2I SAVING LOG DATA nn A 29 KE REAUS SAVE LOG DATA o ee 30 3 32 DELETE ALL LOG DATA standard 30 EE 31 3 9 DEVICE PASSWORD enee ee 31 A EL E 32 DOLL OP EE ene ete Pe ee ene eee am ee E ene ene eae eee 32 702 90 NE eee eee eee ne as 33 EE 33 3 8 CHECK EOW VOLTAGE nadal 34 SS OP ey TES RE 34 FOPA KETTA E tocas 35 3 III POWER ON OFE alla ee 36 3 URGRADE FIRMWARE ee nee nee 36 APPENDIX A SERIAL COMMUNICATION SET UP IN FIMO1 222 222002220000 20000nnn0000n 38 1 THE CHANGE OF BAUD RATE OF FIMO T irocsreriarsissiirica a a o 38 2 THE CHANGE OF BAUD RATE OF EvfoosH 39 PE CONNECTION sedan een 39 APPENDIX B SUPPORT INFORMATION
22. oducts 25 EvTools User Manual NITGEN EvTools In NITGEN In FIMO1 users can be deleted by clicking DELETE RECORD button after checking check boxes of ID to be deleted 3 2 3 DELETE ALL RECORD All DB are deleted by clicking the DELETE ALL RECORD button 3 2 4 SET MASTER Normal user can be changed to master by clicking SET MASTER button after selecting an ID to be master In FDA12 only 5 master IDs are supported 3 2 5 RESET MASTER Master can be changed to normal user by clicking RESET MASTER button after selecting an ID to be normal user 3 2 6 DELETE ALL USER All normal user are deleted by clicking DELETE ALL USER 3 2 7 DELETE ALL MASTER All master are deleted by clicking DELETE ALL MASTER 3 2 8 DOWNLOAD This function is used to get user record composed of registered user ID password encrypted fingerprint minutiae privilege and registered time from FIMO1 and save it as a file If you want to get several user records of DB of FIMO1 you check check box of ID to be downloaded And click the DOWNLOAD button then window shown in Figure 35 pops up Select Type Ge To get checked records To get full records Cancel Figure 35 Window to select method for download If you select To get checked records and then click OK you are able to get user records NITGEN Products 26 EvTools User Manual
23. rate of FIMO1 is changed So serial communication is impossible NITGEN EvTools User Manual Products 38 In NITGEN NITGEN EvTools between FIMO1 and EvTools Close system configuration window 2 The Change of Baud rate of EvTools Select File gt Serial Comm to display the serial communication configuration window then change baud rate as the same as it of FIMO1 3 Reconnection If the baud rate of EvTools is changed successfully try to connect again by clicking the CONNECT button in main window If the baud rate of EvTools and FIMO1 is different EvTools try to connect FIMO1 by changing it automatically NITGEN Products 39 EvTools User Manual In NITGEN NITGEN EvTools Appendix B Support Information NITGEN Co Ltd Sanhak Foundation Bldg 5F 1337 31 Seocho dong Seocho gu Seoul Korea Tel 82 2 3415 1800 Fax 82 2 3415 1801 E mail Customer nigten com NITGEN roducts 40 EvTools Us
24. ssword The device FDA12 FIM10 FIMO1 supports device password that can be used for master authentication without master FP or password Device password should be created only in master mode To create a device password select Tools gt Device Password and then the related window Figure 44 pops up NAC Products 31 EvTools User Manual In NITGEN NITGEN EvTools Device Password SET PASSWORD DELETE PASSWORD Figure 44 Device password window Type the new password up to 15 digits and then click SET PASSWORD button to complete creation On the other hand if you want to delete a master password click the DELETE PASSWORD button 3 6 Set Time This function is used to read date and time from FIMO1 or write date and time to FIMO1 After setting RTC in power on RTC value can be increased FIMO Date amp Time setting E The date amp time set on the FIMOL is Get Time 0000 04 01 00 00 00 The date amp time set on your system PC ts 2004 06 16 16 37 56 Ill type in the date amp time Figure 45 Initial window for date and time This function is only supported in FIMO1 3 6 1 Get Time This is used to read date and time from FIMO1 After click this button date and time set up in FIMO1 displayed as shown in Figure 46 NAC y Products 32 EvTools User Manual In NITGEN NITGEN EvTools FIMO Date amp Time Setting The date amp time set on
25. the FIMO1 is 2004 06 16 16 39 01 The date amp time set on your system PC is 2004 06 15 16 39 04 Set Time ll type in the date amp time Figure 46 Window after clicking Get Time 3 6 2 Set Time Two procedures are used for set up date and time in FIMO1 One is to use date and time set up in PC installed EvTools Only click the Set Time button without check I ll type in the date amp time The other procedure is to input date and time directly Check I ll type in the date amp time and then edit box is displayed as shown in Figure 47 After typing date and time for set up in FIMO1 click the Set Time button FIMO Date Time Setting xj The date amp time set on the FIMOL is Ser TIE 004 06 18 16 39 01 Set Time The date amp time set on your system PC is 2004 06 16 16 40 45 Year Month Day Hour Min Sec bk fe fe fo fe oe Figure 47 Widow for inputting date and time 3 7 VO Control This function is used to turn on off sensor LED of FIMO1 or control relay port Select the menu Tools gt l 0 Control and then control window Figure 48 pops up After selecting control item Sensor LED or Relay proceed test wanted NITGEN Products 33 EvTools User Manual In NITGEN NITGEN EvTools FO Control Relay ChannelO HIGH Loni O Relay Channeli HIGH Lara SUSE Figure 48 I O control window This f
26. unction is only supported in FIMO1 3 8 Check Low Voltage This function is used to check if power level is under low voltage level DC2 1V or not Select the menu Tools gt Check Low Voltage When power is insufficient change batteries Figure 49 Message window indicating sufficient power This function is only supported in FDA12 3 9 Battery Life Test This function is used to check how many times recognition process can be done under battery operation Supply power to FDA12 with battery and then select Tools gt Q A Test gt Battery Life Test The battery life test window Figure 50 pops up and then test starts automatically NITGEN Products 34 EvTools User Manual In NITGEN Battery Life Test E j Count High Voltage 0 a Count Low Voltage 0 NITGEN EvTools Figure 50 The window of battery life test Count High Voltage indicates iteration number of recognition until battery is Low voltage and Count Low Voltage indicates iteration number after battery is Low voltage Sum of two counts becomes usable total count This function is only supported in FDA12 3 10 Packet Trace This function is used to observe transmitted packets between device FDA12 FIM10 FIMO1 and EvTools Select View gt Packet Trace and then packet trace window Figure 51 shows up Packet Trace DIR COMMAND PARAMI PARAM2 DATA SIZE ERR CODE Figure 51
27. xists the same ID the message window such as Invalid ID shows up EvTools x Deletion is succeeded Figure 14 Success message for deletion 2 4 Change This paragraph explains the procedure of changing user record After clicking the CHANGE button in master mode the window to select change mode shown NITGEN Products 15 EvTools User Manual In NITGEN NITGEN EvTools in Figure 15 is displayed Change Fingerprint Database Change Master Privilege amp Save Change Password amp Save Cancel C Change Minutiae from Host Change Minutiae from Sensor Figure 15 The window to select change mode User record structure refers to developer s guide This function is only supported in FIMO1 2 4 1 Change Master Privilege amp Save After selecting the Change Master Privilege amp Save and clicking the OK button the request window for FP ID and privilege shown in Figure 16 is displayed Type ID to be changed privilege and a new privilege and then click the OK button Input Fingerprint ID amp Privilege gt Fingerprint ID me Privilege Ge User C Master Ok Figure 16 Request window for FP ID and privilege The new privilege should be different from enrolled privilege If the new privilege is the same as old it warning message window shown in Figure 18 is displayed and the change procedure gets terminated If the privileg

Download Pdf Manuals

image

Related Search

Related Contents

Ethernet Powerline Adaptor User Manual  安全にお使いいただくために  SMSC USB4640i User's Manual  Magellan Motion Processor Programmer`s Command Reference  Cómo configurar el proyector - Epson America, Inc.  Trust Bulano  NV−S10 取扱説明書    Samsung 900X3K-K02 User Manual(Windows 10)  Guida all`installazione  

Copyright © All rights reserved.
Failed to retrieve file