Home

Copreci Remote Control User Manual

image

Contents

1. comfort in your hands Installation amp user manual Hon BB B2 Tw Set Flame Pilot f 5 COPRECI Contents INSTALLER MANUAL Important information General 1 Technical data 2 Description Installation 1 Positioning the unit 2 Connection 3 Parts description 4 Gas connection 4 1 Pilot and magnetic group 4 2 Touch control buttons 4 3 ODS 4 4 Electronic parts 4 5 Battery connections 5 Pairing 6 Initial configuration USER MANUAL 1 Working with the touch control 1 1 Switching on 1 2 Regulating the flame level 1 3 Switching off 2 Remote control 2 1 Description 2 1 1 LCD display 2 1 2 Four buttons 2 1 1 LCD display 2 1 2 OFF button 2 1 2 Left middle and right button 2 2 Menu system 2 3 Switching on 2 4 Adjust Menu 2 9 Setting the control mode Consult the instructions before using this system The installation of this system must fulfil all the certifications in force Place this label on the appliance Contains FCC ID XO5RXR9400 6000E This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The user is cautioned that any changes or modifications not expressly approved by Copreci could void the users authori
2. Leak testing Brush soapy solution onto the valve and pipe connection areas If expanding bubbles appear there is a leak Close gas source immediately and retighten the connections O copreci r_emotion 4 4 Touch control buttons Connect the touch control to the touch cable Ensure that the triangles on each connector are lined up and facing each other as shown in the illustration Connect the other end of the touch cable to the control unit in the socket marked as TOUCH LED 4 5 ODS Insert the two cables of the ODS in the holes marked as CHASSIS and Insert the thick black cable into the spark plug on the ODS Fix the other cable in place to by inserting the cable terminal underneath the screw on the ODS and then tightening the screw 4 6 Electronic parts Insert the end of the battery box cable into the battery connector on the control unit Connect the valve cable to the control unit Do not forget to connect the chassis wire to the fixation screw A nut is needed to tighten the connector Maximum torque to tighten is 4Nem 2 9LbFt r_emotion gas control system Installer and user manual 4 2 copreci r_emotion 4 7 Battery connections 9 Pairing Once all connections are done supply install batteries the control unit After a while the valve motor will start moving if not wait one minute from the time of supplying the circuit Unlock the remote control in case that is o blocked Once
3. flame will increase instantly To decrease the flame level press the down button v A beep and a flash of the LED indicate that the system has accepted the order and the flame will decrease instantly r_emotion gas control system Installer and user manual 7 O correc r_emotion 1 3 Switching off To switch off the fire the ON OFF button should be pressed After the system has emitted a beep the fire switches off 2 Remote control 2 1 Description The remote control contains 2 1 1 LCD display 2 1 2 Four buttons LCD screen OFF button Left button Middle button Right button i Middle button Left button Right button 2 1 3 Battery case on the back OFF button Batteries__ back side 2 1 1 LCD display The LCD screen shows information about the instructions given by the user desired status and the current situation of the device actual status It also helps us select our choices A Day of the week B Time C Signal strength D Selected working mode E Selected setting F Current flame status G Current fan status H Current room temperature Child lock status J Button labels explained below r_emotion gas control system Installer and user manual 8 Q correc r_emotion Advice The bottom row of the screen is indicating buttons functionality In this case e A V button decreases the flame level e B N
4. the valve has finished moving press the OFF button on the remote control for 40 seconds During this time the screen may go blank it is normal After 40 seconds the setup menu appears All the operation must be done on channel A go to the last option in the setup menu by pressing V and select channel A Configuration fT T h Pairing After that go to pairing option again and press the select button middle button and when off is highlighted press the change button left button off becomes on Gap tenrerature 1 C Programming Yes Thernostatic Yes Once the pairing is on there are 20 seconds to push press and release the button S1 yellow in the control unit Change Back Once this operation is done you hear a beep in the control unit and in the control unit will appear Full The indication on the pairing will become off The pairing is over To return to the home screen press the back button until you get to main screen PS If the pairing has been attempted previously and has not been achieved do the following Prepare the command by pressing the key OFF for 40 seconds Set the channel on channel A Select On in the pairing setting Remove the batteries from the control unit wait 10 seconds and put the batteries back Once the valve has finished moving repeatedly push press and release the S1 button yellow button on the control unit until you hear the beep that confirms that learning has take
5. 9C e lf the Gap Temp is 0 5 C Flame level will go to maximum level because the difference is 2 C e lf the Gap Temp is 19C Flame level will go to medium level as difference of 29C is two times the gap setting The flame level increases two levels Pilot gt Low Medium e lf the Gap Temp is 29C Flame level will go to minimum level as the difference of 2 C is equal to the gap setting The flame level increases one level Pilot Low e Programming this option enables or disables the program mode To enable it select Yes To disable it select No e Fan System this option enables or disables the fan system To enable it select Yes To disable it select No e Soft start this option causes the thermostat mode to work incrementally When the change of flame level reguired by the thermostat involves more than one level this option makes the change step by step with a delay of 10 seconds between each change of flame level To enable this option select Yes To disable it select No e Ember bed This option enables or disables the ember bed output To enable it select Yes To disable it select No e Sounder This option enables or disables the sounder option To enable it select Yes To disable it select No e Safety temp this temperature is the maximum permitted room temperature If the remote detects that the temperature is higher than the Safety temp the appliance is switched off This temperature can never be set hi
6. Adjust Menu Before using the remote there are various settings which should be made such as the date the language the autolock option and the comfort temperature For doing this go to Menu gt Adjust Menu There the options shown below can be set To change any of these settings just press Select and Change Adjust Menu LANGUAGE English Espanol AUTOLOCK COMFORT 0 37 C 32 99 F NIGHT 00 370C 32 998F CHANGE PROGRAM Parameters reguired for program mode r_emotion gas control system Installer and user manual 10 y 2 5 Setting the control mode There are three different modes for controlling the appliance gt Manual gt Automatic gt Program Manual mode lf Manual is pressed Pilot appears as the selected setting In the bottom row V and appear indicating that the flame level can by changed by just pressing the left or middle button Pressing Back right button returns to the initial screen Note that a Safety temperature can be previously set in the configuration menu This specifies the maximum the maximum permitted room temperature This temperature can never be set higher than 40 C 104 F Auto mode If Auto is pressed in the initial screen 25 C 77 F appears as the desired temperature in the selected setting In the bottom row Vv and appear indicating that we can change the desired temperature value by just pressi
7. an one level this option makes the change step by step with a delay of 10 seconds between each change of flame level To enable this option select Yes To disable it select No e Ember bed This option enables or disables the ember bed output To enable it select Yes To disable it select No e Sounder This option enables or disables the sounder option To enable it select Yes To disable it select No e Safety temp this temperature is the maximum permitted room temperature If the remote detects that the temperature is higher than the Safety temp the appliance is switched off This temperature can never be set higher than 40 C 1049F The possible range of values is 25 40 C 77 1049F e Channel There are three different channels available A B and C A change of channel should be done if communication is no good and only after pairing has been done Never try to do channel change and a pairing at the same time To change the channel just press Select choose one of the channels and then reset the control unit by disconnecting the power supply for a short period Afterwards the connection between the remote and the control unit will be re established This process can take 10 seconds r_emotion gas control system Installer and user manual 6 O correc r_emotion User manual The r_emotion system contains The system controls a gas fire with the following functions e A motorized valve e Automatic switch on e An ODS with a s
8. button increases the flame level e C Back button goes back to the previous screen 1 Bottom row The screen changes depending on the input from the buttons but the bottom row always displays the button function labels The function of each button depends on the options available on the current screen except for the OFF button which has always the same function 2 1 2 OFF button This button switches off the appliance If it is pressed for more than 40 seconds the configuration menu is accessed 2 1 2 Left middle and right button These buttons change their function as shown by the on screen labels For some screens a button may have no function and is inactive The active buttons for a particular screen are initially lit for 5 seconds to indicate that they are active 2 2 Menu system The remote is organized by means of a menu system When first powered the remote starts at the OFF screen it is possible that the remote is locked in the OFF screen to unlock it just press the button below Unlock and then OK And then gt r_emotion gas control system Installer and user manual 9 cornea r_ emotion 2 3 Switching on Once the remote is unlocked press On left button and OK middle button A beep from the control unit will be heard and the ignition process starts Note that while in operation the RF signal strength indicator disappears Wait until the current flame status displays Pilot 2 4
9. e heat and should not be placed on a hot surface 4 Connection 4 1 Parts description 1 Valve 4 ODS pilot 7 Touch control r_emotion gas control system Installer and user manual 2 Control unit 5 ODS cable 8 Touch control cable r emotion Suggested positioning of the valve control unit and batteries o 9 Assembly parts O COPRECI 4 2 Gas connection As can be seen in the illustration the gas valve has one inlet 1 and two outlets the pilot outlet 2 and the main burner outlet 3 Maximum torque to tighten inlet and outlet nuts is 8 Nem 5 9Lbft The gas comes through the inlet 1 and when the valve is turned on the gas will start flowing to the pilot outlet 2 After the ignition cycle which lasts approximately 10 seconds has finished different flame levels can be selected allowing gas through the main burner outlet 3 All the necessary parts for carrying out the installation can be found in the box 4 3 Pilot and magnetic group Insert the thread of the ODS pilot 4 in the top of the valve 1 and turn tight Maximum torque to tighten is 4Nem 2 9LbFt Insert the smaller connector of the ODS in the TH OUT male connector on control unit Insert the larger connector of the ODS in the TH IN male connector on the control unit r_emotion gas control system Installer and user manual r emotion
10. eps ERROR Connect supply cable to valve or broken Spark cable disconnected or broken Connect spark cable Stove does not A Program mode does not work if soft ignite in Active soft start start is deactivated program mode Sparks but no pilot Valve cable disconnected or broken ignition ODS cable disconnected or broken Pilot ignites but doesn t Stay on ODS cable disconnected or broken Connect ODS cable Ignites Touch control cable disconnected or CUT a ouch ele commanding broken p from remote Defective touch control buttons Change touch control handset but e Change batteries in the handset not from keyboard Ignites commanding from keyboard but not from remote handset Check reception of signal from a shorter Bad communication with handset GI e Try making the pairing again Try changing the channel in the configuration menu Stove switches off after 6 5 beeps BUTTON ERROR Change touch control wiring Shortcut in touch control seconds batteries in Low Battery Change batteries in the remote the remote 2 cycles of 3 beeps 2 cycles of 3 beeps Try making the pairing again EEPRON ERROR Change control unit The remote is too far from the appliance e The remote has no batteries If this occurs more than once call the technical EMP ERROR service Over Temperature Check correct configuration of safety temperature CONFIG ERROR Change contr
11. gher than 40 C 1049F The possible range of values is 25 40 C 77 104 F e Channel There are three different channels available A B and C These different channels make it possible to have more than one appliance each with its own remote To change the channel just press Select choose one of the channels and then reset the control unit by disconnecting the power supply for a short period Afterwards the connection between the remote and the control unit will be re established Change channel only if necessary r_emotion gas control system Installer and user manual 13 2 correct r_emotion 2 Troubleshooting display BATTERY NO nal OA RAEE 10 beeps ERROR Place new batteries in control unit control unit ROM ERROR ROM Error 2 cycles of 3 beeps Change control unit SUPPORT Support test error 2 cycles of 5 beeps ERROR Connect earth cable from battery box to valve e Change batteries in the remote handset Check reception of signal from a shorter Stove does Bad reception of remote handset distance not ignite signal Try making the pairing again Try changing the channel in the configuration menu No response to touch control If LED is continuously buttons on the cable is Cable loose or broken or connected connected the wrong Ensure the touch control cable is correctly connected see installation manual Change touch control SUPPORT Supply cable to valve disconnected 2 cycles of 5 be
12. king pressure 90 mbar e Inlet connection M12x1 VA e Main burner connection M13x1 1A e Pilot outlet connection M8x1 1 8 e Power supply 4 5V 2 Description r emotion e Power supply current 1 3A e Protection IP20 with cover e Working position Multipoise e Power range 8000 40000 BTU h e Electronics equipped with RUCMB 22600 micro processor e Classification AMVVXK e System type Permanent r_emotion is Copreci s new control system for gas heaters A system than includes a remote control handset for significantly improving the user s communication with the device r_emotion consists of a gas valve with an inlet and two outlets pilot and main outlet a motor that provides step by step sequence adjustment and a control unit that offers a wide range of possibilities POUCH COATROe REMOTE LEL My o 3 Ppa o ben ru wr Y Z l Exstlary Ber 4 Figure 1 Connection scheme C correc Installation 3 Positioning the unit The valve the control unit and the batteries must be installed in a position which avoids excessive heat humidity dust fat and oil The maximum working temperature for these parts is 70 C 158 F Attention should be paid to the specified maximum temperature for the alkaline batteries used to power the system The control unit should not be covered by metal casing so that RF communication is not impeded The touch control can also be damaged by excessiv
13. n place 6 Initial configuration In the configuration menu it is also possible to configure the appliance with the following options e Thermostat this option enables or disables the auto thermostat mode To enable it select Yes To disable it select No e Gap Temp this option refers to the tolerance between the desired temperature and the current one If the difference is greater than this gap temperature setting the flame level increases For example the desired temperature is set at 20 C and the current temperature is 18 C o If the Gap Temp is 0 59C Flame level will go to maximum level because the difference is 29C o lf the Gap Temp is 19C Flame level will go to medium level as difference of 2 C is two times the gap setting The flame level increases two levels Pilot gt Low Medium o lf the Gap Temp is 29C Flame level will go to minimum level as the difference of 2 C is equal to the gap setting The flame level increases one level Pilot Low r_emotion gas control system Installer and user manual 5 2 copreci r_emotion e Programming this option enables or disables the program mode To enable it select Yes To disable it select No e Fan System this option enables or disables the fan system To enable it select Yes To disable it select No e Soft start this option causes the thermostat mode to work incrementally When the change of flame level required by the thermostat involves more th
14. ncluding Daily The selected day can be changed by pressing Change middle button B Day schedule graphic This bar displays the program for the whole day by showing the temperature setting for each hour of the day To access the day schedule graphic press left button To change the desired temperature go to the hour you want to change by pressing gt left button and then press change middle button There are 3 temperature settings OTF no temperature control the appliance is in pilot mode Comfort Tem P afii 4 Fi Ni ght Temp the night temperature is set as the desired Change bac temperature and the appliance will heat until this temperature is reached Comfort Temp the comfort temperature is set as the desired temperature and the appliance will heat until this temperature is reached Finally to launch the program mode in the main menu set Program to On and select the desired Program Type Daily or weekly 2 7 Other features How to change fan speed In the main screen press Menu button Select Fan and press or Wto go to the desired speed How to locking and unlock the remote child lock To unlock the remote press the Unlock button and then OK To lock the remote in the main screen press Menu go to the Lock option press Select and then Change The remote will immediately go into locked mode Automatic lock can be selected This means that if no button is pressed for while the rem
15. ng the left or middle button In auto mode the appliance heats until this temperature is reached Limits are 0 379C 32 99 F Pressing Back right button returns to the initial screen The Auto mode feature is optional and can be enabled or disabled in the configuration menu In this mode the main burner can be switched on and off Program mode There are two types of program mode a Daily mode and a Weekly mode In the daily mode every day uses the same program In the weekly mode every day has its own program so it is possible have a different program for each day of the week In this mode the main burner can be switched on and off r_emotion gas control system Installer and user manual r emotion Automatic mode allows you to set a temperature while in manual mode the flame level may be set to HIGH MEDIUM or LOW Program mode offers automatic temperature control for specific times of the day In the initial screen when the remote is turned on three options are available AUTO MANUAL and MENU Auto and Manual are two of the three different modes for controlling the appliance with the remote cornea r_emotion 2 6 Day programming menu Menu gt Adjust Menu gt Change Program There are 8 menus like this One for Daily and the others for each day Monday Tuesday Wednesday Thursday Friday Saturday and Sunday This day programming screen consists of Title Daily program A Selected i
16. ol unit Appliance Loss of communication between appliance and remote for 18 min 20 beeps switches off High temperature on the control unit 1 long beep Ambient temperature higher than configured r_emotion gas control system Installer and user manual 14
17. ote automatically goes into locked mode How to activate or deactivate the sounder In the main screen press Menu button Select Sounder and press Change to activate or deactivate the sounder How to activate or deactivate the ember bed In the main screen press Menu button Select Ember Bed and press Change to activate or deactivate the sounder How to select the temperature unit C F In the main screen press Menu button Select Adjust Menu and then select Unit To change the temperature unit press Change button r_emotion gas control system Installer and user manual 12 copa r_emotion 2 9 Configuration menu The remote may be used in easy mode by disabling options in the configuration menu If all options are disabled the remote works in manual mode only Furthermore the only on screen option are Manual and Menu Within the menu only Adjust Menu and Lock are accessible This is a list of the settings that can be changed in the configuration menu e Thermostat this option enables or disables the auto thermostat mode To enable it select Yes To disable it select No e Gap Temp this option refers to the tolerance between the desired temperature and the current one If the difference is greater than this gap temperature setting the flame level increases For example the desired temperature is set at 209C and the current temperature is 189C For example set temperature is 209C and current temperature is 18
18. park plug for the sparking e Automatic switch off e A control unit e 4 different flame levels pilot minimum medium e A battery box or power supply maximum e A remote control The flame level can be controlled in 3 different ways e A touch control optional e Manually via touch control or remote control e A touch control cable optional e Automatically only via remote control e An ODS cable e By timed program only via remote control e Assembly parts The r_emotion system can be used with two different controls touch control and remote control Both methods can be used at the same time to control the system 1 Working with the touch control This touch control has only 3 buttons for controlling manually the flame of the appliance The touch has 1 Led display a 2 ON OFF button A 3 UP button 4 4 DOWN button v With this control it is possible to turn on the fire turn off the fire and control the flame level 1 1 Switching on To turn the system on just press the ON OFF button The system will emit a beep and begin the ignition process which can take about 20 seconds Once the start up process is complete the pilot flame is lit if the system does not have a pilot mode the main burner is switched on at the lowest level 1 2 Regulating the flame level To increase the flame level press the up button 4 A beep and a flash of the LED indicate that the system has accepted the order and the
19. ty to operate the eguipment 2 6 Day programming menu Menu gt Adjust Menu gt Change Program 2 6 Other features 3 Troubleshooting Revision history Date Changes Final 15 06 2009 Preliminary document 23 06 2009 Corrections to English Important information e All cables must be connected as described in the installation manual The gas installation must be carried out by a professional installer Electronics components must be installed in a cool area below the fire If temperature rises above 70 C 158 F the appliance switches off The control unit should be positioned as shown in the illustration Use only alkaline batteries and insert batteries with the polarity correctly aligned No maintenance is reguired Cleaning the valve with soapy water can damage it No component should ever be repaired if a part malfunctions it should always be replaced by a qualified technician Any change to the type of gas must be carried by a professional installer Do not pour liquids on any of the components e Once the installation process is completed the installer should ensure that the appliance is working properly RF range is dependent on the appliance characteristics Manufacturers must check that the communication distance of their appliance is adequate C correc General 1 Technical data e Max flow rate 480 I hr air 1mbar e Temperature range 0 70 C 32 158 F e Maximum wor