1. Never touch bulb with bare fingers as it is very hot after using Hot lamp explosion hazard Do not open the unit within five minutes after switching off Do not start on the unit without bulb enclosure or housing is damaged The housing the lenses must be replaced if they are visibly damaged Do not look directly at the light while the bulb is on Caution There are no user serviceable parts inside the unit Do not open the housing or attempt any repairs by yourself Rigging the fixtures The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture 5A Description O ON OO fF W N Optical lens with manual focus adjustment Hanging bracket with one knob to fasten the unit Power cord comet only to a matching power outlet Build in fuse Lamp accessory door Internal microphone Cooling fan Reflector mirror Selector switch to select between auto sound activation or static function 6A Operation and Technical Specification Plugging into the mains power and it will start running The unit runs in automatic sound activated or static mode
2. The cleaning of internal and external optical lenses or mirror must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics e Clean with soft cloth using normal glass cleaning fluid e Always dry the parts carefully e Clean external optics at least every 20 days and internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 amp Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements 14A
3. e Focus adjustable by manual Specification e Voltage AC 120V 60Hz US AG 230V 240V 250V 50Hz 60Hz EU e Fuse 20 mm glass 120V T5A US 20 mm glass 250V T3 15A EU e Lamp EFP 12V 100W e Dimension 266 X 142 X 144 mm Weight 1 7 kgs Installation The unit could be mounted on the wall or under ceiling If the buyer installs the unit under ceiling please use a clamp optional to fix the unit under ceiling Always ensures that the unit is firmly fixed to avoid vibration and slipping while operating Always ensures that the structure to which you are attaching the unit is secure Place on the ground Clamp on the truss Hang on the wall 7A Exchange Lamp DANGER In case of replacement of the lamp do not open the lamp accessory door within 15 minutes until the unit cools down after switching off LAMP EFP 12V 100W 1 Always switch off the main supply and never handle the lamp or luminaries when is hot 2 Do not touch the bulb with bare hands If this happens clean the lamp with denatured alcohol and wipe it with a lint free cloth before installation 3 Never operate the lamp without appropriate shielding 4 Make sure the lamp is located in the center for the best spot 1 Unscrew the screw from the lamp accessory door 2 Remove the cover 8A 3 Take off the lamp with carefully 4 Replace the new lamp 5 Push gently with thumb and make sure the lamp was located on the central zone with
4. tight for best light effects 6 Reverse step 2 to step 1 9A Exchanging Rotating Gobos Warning the function for Junior Fascination only DANGER Install the gobo when the power is off for 15 minutes only If you wish to use other patterns as the standard gobo please follow the below steps with carefully 1 Unscrew the screw from the lamp accessory door 2 Remove the cover and unscrew from the gobo plate 3 Remove the gobo wheel 10A 4 Notice the front and reverse side 5 Remove steel ring from front side then take off the gobo 6 Exchange to new gobo and fasten with steel ring 7 CAUTION Please make sure the gear wheel is correct 8 Reverse step 2 to step 1 11A Exchange Fuse DANGER In case of replacement of fuse please awaiting 15 minutes until the unit cools down after switching off 1 Push and rotate with arrow by thumb 2 Remove the protect tube of fuse 3 Exchange new fuse with same model 4 Plug in the protect tube 5 Push and rotate with arrow by thumb 6 Finished 12A Troubleshooting No power to the fixture Check power connections please check and replace fuse if Fuse power is on Burned out of lamp Install new lamp Allow to cool down and improve air No light Fixture too hot l flow around the unit Sound sensitivity Increase volume No action Electrical malfunction Refer to service technician 13A Fixture Cleaning
5. nnnnnnnnnnnnnn aes eeseeeeeeee cence 14 3A Safety Instruction N Please read carefully the instruction which includes important information WARNING about the installation usage and maintenance Please keep this User Manual for future consultation Unpack and check carefully there is no transportation damage before using the unit Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit The unit is for indoor use only and only in a dry location Disconnect mains power before fuse lamp replacement or servicing Replace fuse lamp only with the same type Make sure there are no flammable materials close to the unit while operating as it is fire hazard Maximum ambient temperature is TA 40 C Don t operate it where the temperature is higher than this Turn off the power and allow about 15 minutes for the unit to cool down before replacing bulb or serving In the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Do not touch any wire during operation as high voltage might be causing electric shock 4A Warning To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture
6. u Serie User manual ACME Version 1 0 Introduction Thank you for purchasing Junior Series the unit is a powerful 100W effect lights Plug amp play and easy to use any where enjoys the pleasurable light show Selector switch for 3 sets of auto sound activation or static function mode to dynamic emotion applications Junior series without any duty cycle equip with super cooling fan built up a fantastic light show to dancing all night Safety with thermo switch ensures auto power disconnection when errors or defects happen This fixture is perfect for clubs pubs bars parties and mobile DJs Junior Series for Hallucination Fascination and Orbiter 2A TABLE OF CONTENTS Introduction Prrrrrrrrrrrrr rrr rrr rrr rrr rrr rrr rrr rrr rrr rrr rrr rrr rrr rrr rrr rrr rrr rrr rrr ere ere ET ere ee ee eee AAA 2 LE TE EE nes ad BEEN ccc 5 Operation and Technical Specification KN EN EE RA EE EIN er metalation TE EE EE ee E re ee ee JG EREIE DE cnn non nnnnnn oran nnn nn nan nnnnnn nn non nnnnnnnnnnnnnnnnnnnnnannnnnnnnnos 8 Exchanging Rotating GODOS sesse see EE ee EE Ee EE OE EE coo EE ooo EE cronos cocos oro EE occ nenne nenne 10 Exchange Fuse see ss ee EES ER EE GEE Re EER EER SEE ER EE Gee Gee ER EER Gee ee EE Gee Gee ER EER Gee see es sence x Troubleshooting tttttrsrrtrrnnnannennannnnnnnnenennnannnnnenenennnnnnnennnnnnanennensnnnnnnesennnnnnene 2 18 Fixture Cleaning eerrrerrterrrnoonnnnnnnnnnnnnn
Download Pdf Manuals
Related Search
Untitled untitled boxing game codes untitled document untitled goose game untitled notepad untitled spreadsheet untitled paint untitled app untitled presentation untitled 1 untitled entertainment untitled boxing codes untitled boxing game untitled attack on titan codes untitled tag game codes untitled stream untitled ui untitled 2 untitled paint 3d untitled design untitled diagram untitled boxing game wiki untitled mod menu untitled goose untitled form untitled music app
Related Contents
Manual de Instalação e Operação Myoguide Operator`s Manual - Intronix Technology Corporation Sw itch To To tal Freed o m CLÉ DE SÉCURITÉ OTP Manuel d`utilisation Utiliser Alcatel 2004C 2.4" 89g Black Mounting and Operating Instructions EB 3009 EN User Manual TC(R)110 - Leica Geosystems 取扱説明書はこちら 取 扱 説 明 書 - Acuvance Copyright © All rights reserved.