Home

102MC-FL Manual 8-2-07

image

Contents

1. LED Cole Description GREEN Powers Applied OFF Power is OFF GREEN 10 Mb Link between ports LNK OFF No Link between ports GREEN Datais active between ports ACT OFF Data is inactive between ports 8 2 2007 7 APPLYING POWER Top View Uns Install the DC Power Cables into the Plug observing polarity Plug the Voltage Input Plug back into the Power Input Header Tightening torque for the terminal block power plug is 0 22 Nm 0 162 Pound Foot Verify the Power LED stays ON GREEN Note Only 1 power supply must be connected to power for minimal operation For redundant power ation Vi and Vi inputs must be connected to separate DC Voltage sources This device will draw current from both sources simultaneously Use 16 28 gauge wire when connecting to the power supply Recommended 24V DC Power Supplies similar to 100VAC 240VAC N Tron s NTPS 24 1 3 DC 24V 1 3A 8 2 2007 N TRON SWITCH GROUNDING TECHNIQUES The grounding philosophy of any control system is an integral part of the design N Tron switches are designed to be grounded but the user has been given the flexibility to float the switch when required The best noise immunity and emissions i e CE are obtained when the N Tron switch chassis is connected to earth ground via a drain wire Some N Tron switches have metal din rail brackets that can ground the switch if the din rail is grounded In some cases N Tron switch
2. straight through cable for a PC Any N Tron switch will automatically determine what MDIX the 102MC is using and will connect it to the network Note The 102MC is a transparent media converter Both the fiber port and the copper port must be linked in order for the unit to display any link status on the link LEDs At least one of the two ports must be hard set to 10Base if the fiber device is 10Base FL then it is automatically set to 10Base TROUBLESHOOTING i 2 Make sure the Power LED is ON Make sure you are supplying sufficient current for the version chosen Note The Inrush current will exceed the steady state current by 2X Verify that Link LED s are ON for both ports Verify cabling used between stations Verify that cabling is Category 3 or greater for 10Mbit Operation The 102MC is a transparent media converter if one side isn t linked properly both ports will not indicate a valid link 8 2 2007 ll SUPPORT Contact N TRON Corp at TEL 251 342 2164 FAX 251 342 6353 www n tron com support n tron com FCC STATEMENT This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful Interference 2 This device must accept any interference received including interference that may cause undesired operation 8 2 2007 12 KEY SPECIFICATIONS Physical Height 349 Width 201 Depth 4 00 W
3. DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSONS MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO OPEN REPAIR OR MODIFY THE PRODUCT OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING POWER CUTS OR OUTAGES OTHER HAZARDS OR ACTS OF GOD LIMITATION OF LIABILITY TO THE FULL EXTENT ALLOWED BY LAW N TRON ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE OR PROFITS LOSS OF BUSINESS LOSS OF INFORMATION OR DATA OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF N TRON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND LIMITS ITS LIABILITY TO REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE DISCLAIMER Some countries states or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental or consequential damages for certain products supplied to consumers or the limitation of liability for personal i
4. PTION Upon registration this product qualifies for advance replacement A replacement product will be shipped within three 3 days after verification by N TRON that the product is considered defective The shipment of advance replacement products is subject to local legal requirements and may not be available in all locations When an advance replacement is provided and customer fails to return the original product to N TRON within fifteen 15 days after shipment of the replacement N TRON will charge customer for the replacement product at list price WARRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRONS OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH DESCRIPTION AND NON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED N TRON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS N TRON SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION
5. THE INDUSTRIAL NETWORK COMPANY 102MC Industrial Media Converter User Manual amp Installation Guide 8 2 2007 N IRON THE INDUSTRIAL NETWORK COMPANY Industrial Media Converter Installation Guide 102MC The 102MC is a 2 port unmanaged transparent media converter that converts 10Base T copper to 10Base FL half duplex fiber 8 2 2007 Copyright N TRON Corp 2005 820 S University Blvd Suite 4E Mobile AL USA 36609 All rights reserved Reproduction adaptation or translation without prior written permission from N TRON Corp is prohibited except as allowed under copyright laws Ethernet is a registered trademark of Xerox Corporation All other product names company names logos or other designations mentioned herein are trademarks of their respective owners The information contained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein Warning Do not perform any services on the unit unles the unit qualified to do so Do not substitute unauthorized parts or make unauthorized modific
6. ations to Do not operate the unit with the top cover removed as this could create a shock or fire hazard Do not block the air vents on the sides or the top of the unit Do not operate the equipment in the presence of flammable gasses or fumes Operating electrical equipment in such an environment constitutes a definite safety hazard Do not operate the equipment in a manner not specified by this manual Safety Warnings GENERAL SAFETY WARNING If the equipment is used in the manner not specified by N TRON Corp the protection provided by the equipment may be impaired Contact Information N TRON Corp 820 South University Blvd Suite 4E Mobile AL 36609 TEL 251 342 2164 FAX 251 342 6353 Website www n tron com Email support n tron com 8 2 2007 ENVIRONMENTAL SAFETY WARNING Disconnect the power and allow to cool 5 minutes before touching ELECTRICAL SAFETY A A isconnect the power cable before removing the enclosure top WARNIN WARNING o not operate the unit with the top cover removed WARNING Do not work on equipment or cables during periods of lightning activity WARNING o not perform any services on the unit unless qualified to do so WARNING Do not block the air vents WARNING Observe proper DC Voltage polarity when installing power input cables Reversing voltage polarity can cause permanent damage to the unit and void the warranty 8 2 2007 PACKAGE CONTENTS Please mak
7. e sure the Serial over Ethernet package contains the following items 1 102MC Media Converter 2 Product CD Contact your carrier if any items are damaged INSTALLATION Read the following warning before beginning the installation WARNING Never install or work on electrical equipment or c when hazardous gasses are present ling during periods of lightning activity Never connect or disconnect power Disconnect the power cable before removing the enclosure top Do not operate the unit with the top cover removed UNPACKING Remove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth SERVICING Jumper J3 can be changed on the board to change the RJAS copper port s MDIX setting See Connecting the Unit on page 8 for more details 8 2 2007 DIN Rail Mounting Install the unit on a standard 35mm DIN Rail Recess the unit to allow at least 5 of horizontal clearance for the fiber optic cable J bend radius WEA To install the unit to 35mm industrial DIN Rail place the top edge of the included mounting bracket on the back of the unit against the DIN Rail at a 15 angle as shown Rotate the bottom of the unit to the back away from you until it snaps into place 300 PM 900 PM 900 RM 8 2 2007 To remove the unit from the 35mm industrial DIN Rail place a flat head screwdriver into the ora
8. eight 0 75 Ibs DIN Rail 35mm Electrical Redundant Input Voltage 10 30 VDC Regulated Input Current 80 mA 24VDC Steady State Inrush Current 7 3Amp 1 0ms 24VDC Input Ripple Less than 100 mV Input Wire Size 16 28 AWG Environmental Operating Temp 200C to 70 C Storage Temp 400C to 85 C Operating Humidity 10 to 90 Non Condensing Operating Altitude Oto 10 000 ft Shock and Vibration Shock 2009 10ms Vibration Seismic 50g 5 200Hz Triaxial Note Unit must be Bulkhead mounted to achieve these levels Reliability MTBF gt 2Million Hours Network Media 10BaseT gt Cat3 Cable 10BaseFL 50 125 um Fiber 850nm 62 5 125 um Fiber 850nm 100 140 um and 200 um Fiber 850nm Connectors 10BaseT One 1 RJ 45 Copper Port 10BaseFL SC or ST Duplex Port Recommended Wiring Clearance Front 2 5 08 cm Top 3 7 62 cm Emissions and Safety Approvals FCC Part 15 Class A 8 2 2007 TRON Limited Warranty N TRON Corp warrants to the end user that this hardware product will be free from defects in workmanship and materials under normal use and service for the applicable warranty period from the date of purchase from N TRON or its authorized reseller If a product does not operate as warranted during the applicable warranty period N TRON shall at its option and expense repair the defective product or part deliver to customer an equivalent product or part to replace the defective item or re
9. es with metal brackets can be supplied with optional plastic brackets if isolation is required voqmerauconnn Both V legs of the power input connector are connected to chassis internally on the PCB Connecting a drain wire to earth ground from one of the V terminal plugs as shown here will ground the switch and the chassis The power leads from the power source should be limited to 3 meters or less in length DRAIN WIRE WITH LUG CONNECTING KNOWN GROUNDING POINT As an alternate users can run a drain wire amp lug from any of the Din Rail screws or empty PEM nuts on the enclosure When using an unused PEM nut to connect a ground lug via a machine screw care should be taken to limit the penetration of the outer skin by less than 1 4 in Failure to do so may cause irreversible damage to the internal components of the switch HM Note Before applying power to the grounded switch you must use a volt ORAIN WIRE WITH LUGS d iffere CONNECTING SWITCH meter to verify there is no voltage difference between the power supply s CONNECTING swoi negative output terminal and the switch chassis grounding point GROUNDING POINT A METALLIC DIN RAIL MOUNT The use of shielded cables between devices is not required for most N Tron devices please consult the user manuals for specific details If the use of shielded cables is required it is generally recommended to only connect the shield at one end to prevent ground loops and
10. fund to customer the purchase price paid for the defective product All products that are replaced will become the property of N TRON Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the remainder of the initial warranty period whichever is longer N TRON shall not be responsible for any custom software or firmware configuration information or memory data of customer contained in stored on or integrated with any products returned to N TRON pursuant to any warranty OBTAINING WARRANTY SERVICE Customer must contact N TRON within the applicable warranty period to obtain warranty service authorization Dated proof of purchase from N TRON or its authorized reseller may be required Products returned to N TRON must be pre authorized by N TRON with a Return Material Authorization RMA number marked on the outside of the package and sent prepaid and packaged appropriately for safe shipment Responsibility for loss or damage does not transfer to N TRON until the returned item is received by N TRON The repaired or replaced item will be shipped to the customer at N TRON s expense not later than thirty 30 days after N TRON receives the product N TRON shall not be responsible for any software firmware information or memory data of customer contained in stored on or integrated with any products returned to N TRON for repair whether under warranty or not ADVANCE REPLACEMENT O
11. interfere with low level signals i e thermocouple RTD etc CatSe cables manufactured to EIA 568A or 568B specifications are required for use with N Tron Switches METALLIC NONMETALLIC i SHIELDED PATCH CABLE Note Strain relief boots not shown for clarity purposes In the event all CatSe patch cable distances are small i e All Ethernet devices are located the same local cabinet and or referenced to the same earth ground it is permissible to use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals 8 2 2007 9 RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications masa T AT5e CAB Caran me A EIA 568B Loi 8 2 2007 10 CONNECTING THE UNIT For the 10Base FL Fiber Optic port remove both of the dust caps from the fiber optic connectors and connect the fiber optic cables The TX port on the local unit should be connected to the RX port of the far end device and the RX port should be connected to the TX port of the far end device For 10Base T port plug a Category 3 or better twisted pair cable into the RJ45 connector Connect the other end to the far end device Verify that the LNK LED s are ON once both the fiber and the copper are linked The MDIX mode of the 102MC can be changed using jumper J3 on the board By factory default the device is set up to use a
12. nge release clip found at the bottom of the unit and apply downward force on the clip until it disengages from the bottom of the unit from the DIN Rail Rotate the bottom of the unit towards you and up at an approximate 15 upward angle to completely remove the unit With the exception of the S24TX and 526FX2 all N Tron products are designed to be mounted on industry standard 35mm DIN Rail However DIN Rail mounting may not be suitable for all applications We offer three alternative mounting solutions Our 300 Panel Mount Assembly P N 300 PM may be used to mount a single 100 or 300 Series unit to a panel or other flat surface Our 900 Panel Mount Assembly P N 900 PM may be used to securely mount our 100 200 300 400 500 or 900 Series products to a panel or other flat surface Our Rack Mount Assembly P N 900 RM may be used to mount our products to standard 19 racks FRONT PANEL 102MC O N TRON RX TX From Top to Bottom o Green LED lights when Power is connected RJAS Port 10Base T Connection ACT Activity LED for Fiber Optic Port LNK Link LED for Fiber Optic Port RX Fiber Optic Receiver Port TX Fiber Optic Transmitter Port NOTE The RJ45 data port has two LED s located at the left side of the connector The top LED indicates Activity ACT and the lower LED indicates Link LNK status LED s The table below describes the operating modes
13. njury so the above limitations and exclusions may be limited in their application to you When the implied warranties are not allowed to be excluded in their entirety they will be limited to the duration of the applicable written warranty This warranty gives you specific legal rights which may vary depending on local law GOVERNING LAW This Limited Warranty shall be governed by the laws of the State of Alabama U S A 8 2 2007 14

Download Pdf Manuals

image

Related Search

Related Contents

  SRT−G060 取扱説明書 - 株式会社 旭エンジニアリング  Olympus 36R Digital Camera User Manual  ダウンロード    HTR4901 - Makita  HMC703LP4E - Analog Devices  Métamorphoses d`Arachné  

Copyright © All rights reserved.
Failed to retrieve file