USER GUIDE - Acandia AB
Contents
1. 1 3 6 1 4 1 22626 1 2 1 1 3 6 1 4 1 22626 1 2 1 1 Actual measured temperature String 1 3 6 1 4 1 22626 1 2 1 2 Actual measured relative humidity String 1 3 6 1 4 1 22626 1 2 1 3 Actual measured computed quantity String 1 3 6 1 4 1 22626 1 2 1 4 Actual measured atmospheric pressure String 1 3 6 1 4 1 22626 1 2 1 5 Temperature alarm state none high low String 1 3 6 1 4 1 22626 1 2 1 6 Relative humidity alarm state String 1 3 6 1 4 1 22626 1 2 1 7 Computed quantity alarm state String 1 3 6 1 4 1 22626 1 2 1 8 Atmospheric pressure alarm state String 1 3 6 1 4 1 22626 1 2 1 9 Temperature unit String 1 3 6 1 4 1 22626 1 2 1 10 Relative humidity unit String 1 3 6 1 4 1 22626 1 2 1 11 Computed quantity unit String 1 3 6 1 4 1 22626 1 2 1 12 Atmospheric pressure unit String 1 3 6 1 4 1 22626 1 2 2 1 3 6 1 4 1 22626 1 2 2 1 Device name String 1 3 6 1 4 1 22626 1 2 2 2 Device setial number String 1 3 6 1 4 1 22626 1 2 2 3 Device type String 1 3 6 1 4 1 22626 1 2 3 1 3 6 1 4 1 22626 1 2 3 1 Actual measured temperature Int 10 1 3 6 1 4 1 22626 1 2 3 2 Actual measured relative humidity Int 10 1 3 6 1 4 1 22626 1 2 3 3 Actual measured computed quantity Int 10 1 3 6 1 4 1 22626 1 2 3 4 Actual measured atmospheric pressure Int X 1 3 6 1 4 1 22626 1 2 3 5 Temperature alarm 0 none 1 high 2 low Integer 1 3 6 1 4 1 22626 1 2 3 6 R
2. 36 Computed quantities ene e 36 Operating RON HR DRE EU ARG ERREUR 38 Of operatio wsze 39 Technical support Service se osocza OWOC ELA 39 Pr ventiye MAINTENANCE zeza YYY 39 Optional aCcESSONESt cones 40 IE SNC Tx5xx 24 Introduction This chapter provides basic information about device Before starting please read this manual carefully The Web Sensor devices are designed for measurement of temperature relative humidity and atmospheric pressure in air without aggressive substances Measured quantities are according device type Devices with relative humidity measurement can show one of computed quantities dew point temperature absolute humidity mixing ration and specific enthalpy Temperature units are C or F Pressure units are hPa PSI inHg mBat oz in mmHg inH O and kPa Communication interface of Web Sensors is Ethernet Device types Temperature Relative humidity Pressure Computed quantity lt lt lt v Y Web Sensor Tx5xxP devices ate designed fot measurement in compressed air up to 25 bars The removable probe is integral part of the device It is not possible to interchange probe betw
3. C Serial R5232 C Serial R5485 X taca the window shows all available devices on your network Find device MAC address EM gt a Search Help My device wasn t found Cancel 3 Change IP click to Change IP to set new address according to network administrator instructions If your device is not listed then click Help My device wasn t found Then follow the instructions MAC address is on product label The device is factory set to IP 192 168 1 213 Change Device IP Address Old device IP address Device MAC address estado zu d X gateway may not be entered if you want to use the device only in local netwotk If you set the same IP address which is already used the device will not work correctly and there will be collisions on the network If the device detects a collision of IP address then reboot is performed automatically after changing IP address device is restarted and new IP address is assigned Restart of the device takes about 10 seconds connect to device using TSensor software and check the measured values Set the other parameters alarm limits SMTP server etc Settings are saved after click on button Save changes IE SNC Tx5xx 24 Checking functions The last step is to check measured values on the device website In the address bar of the web browser enter the device IP address If the default IP address was not cha
4. 17510 155 T3511 1m probe 210g T3511 2m probe 250g T3511 4m probe 330g T13511P 1m probe 260g T3511P 2m probe 300g T3511P 4m probe 380g T7511 1m probe 210g T7511 2m probe 250g T7511 4m probe 330g Mounting the device With two holes at the bottom of the unit Communication port RJ45 connector 10Base T 100Base TX Ethernet Auto Sensing Recommended Connector Cable for industrial use is recommended Cat5e STP cable in less demanding applications can be replaced by Cat5 cable maximum cable length 100m Supported protocols TCP IP UDP IP ARP ICMP DHCP TFTP DNS HTTP SMTP SNMPv1 ModbusTCP SNTP SOAPv1 1 Syslog Supported web browsers Internet Explorer 9 Mozilla Firefox 12 and later Google Chrome 18 and later Opera 11 and later Safari 5 and later Device should be also compatible with other browsers Functionality wasn t tested with other web browsers Recommended minimum screen resolution 1024 x 768 Memory 1000 values for each channel inside non backup RAM memory EMC emission EN 55022 Class B EMC resistance EN 61000 4 2 levels 4 8kV Class A EN 61000 4 3 intensity of electromagnetic filed 3V m Class A EN 61000 4 4 levels 1 0 5kV Class A EN 61000 4 6 intensity of electromagnetic filed 3V m Class A 34 IE SNC Tx5xx 24 Measured values Relative humidity Pressure Computed quantity Temperature measurement Temperatur
5. Error value 9999 or 9999 lt pressute gt Contains the value of atmospheric pressure Error value 9999 lt alarms gt State of alarm on temperature relative humidity computed quantity and pressure channel Format tm rh cq pr where tm temperature alarm rh relative humidity alarm cq computed quantity alarm pr atmospheric pressure alarm and alarm values no no alarm or value is not supported hi high alarm lo low R alarm lt compType gt Computed quantity type Absolute humidity Specific humidity Mixing proportion Specific enthalpy Dew point or n a lt tempU gt Temperature and dew point unit Values C temperature in C F temperature in F lt pressureU gt Atmospheric pressure unit Values hPa PSI inHg mBar oz in 2 mmHg inH20O and kPa timer SOAP sending interval sec 25 IE SNC Tx5xx 24 Example of the web service for incoming SOAP messages from Web Sensor Tx5xx Example uses Apache 2 2 10 web server and PHP 5 2 6 It is required to install and enable SOAP extension for PHP This example store incoming messages to the hard drive lt function InsertTx5xxSample passKey device temp relHum compQuant pressure alarms compType tempU pressureU timer data Time StrFTime y m d H M S Time Temp temp RH relHum CQ compQuant Pressure press
6. Internal memory CRC error In this state device doesn t work This is a critical error contact the distributor Error 1 Err1 Measured or computed quantity is over the upper limit Error code 9999 This state appears in case of Measured temperature is higher than approximately 600 C i e high non measurable resistance of temperature sensor probably open circuit Relative humidity is higher than 100 RH i e damaged humidity sensor or humidity calculation is not possible due to temperature error Unable to calculate computed quantity temperature or humidity measurement error Error 2 Err2 Measured or computed quantity is under lower limit or is error in pressure measuring Error code 9999 This state appears in case of Measured temperature is lower than approximately 210 C ie resistance is too small probably short circuit Relative humidity is lover than 0 RH ie damaged humidity sensor or humidity calculation is not possible due to temperature error Measured atmospheric pressure with offset is over range 300hPa to 1350hPa or the pressure sensor is damaged Unable to calculate computed quantity temperature or humidity measurement error Error 3 Err3 Internal A D converter error Error code 9999 In this state device doesn t wotk Contact the distributor Error 4 Err4 Internal pressure sensor error Error code 9999 In this state device not measure pressure Co
7. relative humidit relativni vihkos 30 20 10 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 temperature teplota C Atmospheric pressure measurement Accuracy 23 0 lt lt 40 C hPa 600 to 1100 t1 3 1 5 2 0 mBar 600 to 1100 1 3 1 5 2 0 PSI 8 70 to 15 95 0 02 0 02 0 03 mmHg 450 0 to 825 1 1 0 1 1 1 5 inHg 17 72 to 32 48 0 04 0 04 0 06 inH2O 240 9 to 441 6 0 5 0 6 0 8 toz in 139 2 to 255 3 0 3 0 3 0 5 kPa 60 00 to 110 00 0 13 0 15 0 20 Atmospheric pressure response time t90 lt 44s Response time is selectable More detail you find in calibration manual which is included with TSensor software installation Computed quantities Dew point temperature Range 60 to 80 C 20 to 176 F Accuracy 1 5 C 2 7 F at ambient temperature T lt 25 C 77 F and RH gt 30 for more details see graphs 36 IE SNC Tx5xx 24 100 100 T 80 gt 80 BN 1 5 e z 50 2 S 60 5 40 o c 8 20 1 5 o 40 0 2 5 20 20 5 0 40 ZA 0 60 20 0 20 40 60 80 100 120 20 0 20 40 60 80 100 120 process temperature T C process temperature T C Specific humidity This value depends on atmospheric pressure
8. Subnet mask Gateway DNS are left without changes Settings relating to measurement are not restored by factory defaults EMS mim Settings General General device settings Network Basic settings of the network interface Alarm limits Configuration of the alarm limits Measurin Units display settings etc SOAP protocol Setup SOAP protocol for database system Email Alarm emails configuration Protocols Syslog and ModbusTCP protocol settings SNMP SNMPv1 protocol and SNMP Traps Time Synchronization with NTP server WWW and Securit y Web server and Security configuration RSA Factory defaults info etc Maintenance Info Basic informations about device Find more detailed information on the diagnostic page Please send the diagnostic file together with request to support Device type Serial number MAC address Firmware version Build firmware notice Device uptime Diagnostic file Restart T7511 11963408 00 20 4A A6 E7 BD 1 5 5 0 0978 1 00 RTM 4h 29 min 28 sec 192 168 1 41 diag log Device will be restarted after dialog confirmation All history values are cleared after restart Restarting of the device will take a few second Factory defaults s Restart device Factory defaults button restores device to factory settings Network parameters like a IP address subnet mask and gateway IP will not be changed Factory defaults Netwotk parameters ate changed while you close
9. fot it Unsupported firmware can damage your device Device does not support powering over Ethernet cable PoE PoE splitter must be used Compatible PoE splitter can be purchased as optional accessories Splitter must have 12V output with approximately 1W Reliability of warning messages delivering e mail trap syslog depends on actual availability of necessary network services The device should not be used for critical applications where malfunction could cause to injury or loss of human life For highly reliable systems redundancy is essential For more information please see standard IEC 61508 Never connect the device directly to the Internet If it is necessary connect the device to the Internet properly configured firewall must be used Firewall can be partially replaced by the NAT IE SNC Tx5xx 24 Getting started Here you can find informations necessary to put newly purchased equipment to operation This procedure is only informative What is needed for operation To install the unit you need to the following equipment Before installation check if it s available Web Sensor Tx5xx device power supply adapter 9 30V 200mA RJ45 LAN connection with appropriate cable free IP address in your network for Web Sensor T4511 is required temperature probe Pt1000 3850ppm connected by shielded cable with maximum length 10m Mounting the device check if the equipments from previous chapter are available instal
10. network interface Alarm limits Configuration of the alarm limits Measurin Units display settings etc SOAP protocol Setup SOAP protocol for database system Email Alarm emails configuration Protocols Syslog and ModbusTCP protocol settings SNMP SNMPv1 protocol and SNMP Traps Time Synchronization with NTP server WWW and Securi Web server and A Maintenance Factory defaults info etc Network General General device settings Device name can be changed to user specified name History graphs and tables will be cleared after changing history storage interval Device name History storage interval Web Sensor 1 Min v Apply settings Cancel changes Network parameters can be obtain automatically from DHCP server using option Obtain an IP address automatically Static IP address is configurable via field IP address It is not necessary setup Default gateway while you use device inside one subnet only DNS server IP is required to set for proper function of DNS Option Standard subnet mask sets network mask automatically according A B or C netwotk class Subnet mask field must be set manually when network with non standard range is used Periodic restart interval enables to restart device after selected time since device start Back Exit to main menu Settings General General device settings Basic settings of the network interface Alarm limits Configuration
11. of the alarm limits Measuring Units display etc SOAP protocol Setup SOAP protocol for database system Email Alarm emails configuration Protocols Syslog and ModbusTCP protocol settings SNMP SNMPv1 protocol and SNMP Traps Time Synchronization with NTP server WWW and Securi Web server and Security configuration Maintenance Factory defaults info etc Measuring Display Display can be configured to show required values It is recommended to switch off display when device is used in temperature over 70 C LCD enabled Show Temperature v Show Relative humidity Show Computed value Show Atmospheric pressure Units Device measures values according selected physical units History graphs and tables will be cleared after changing units Temperature Unit Computed value Dew point Atmospheric pressure Unit kPa Other settings Compensation of measured values and other settings For more information read the user guide carefully Pressure value for computed values 1013 hPa Atmospheric pressure offset 0 0 hPa Apply settings Cancel changes 14 IE SNC Tx5xx 24 SOAP protocol SOAP protocol can be enabled by option SOAP protocol enabled IP addtess of the destination http server is configurable via SOAP server IP address filed For setup of destination server port can be used option SOAP server port Target place of the http setver c
12. of the alarm limits Measuring Units display settings etc SOAP protocol Setup SOAP protocol for database system Email U Alarm emails configuration Protocols Syslog and ModbusTCP protocol settings SNMP SNMPv1 protocol and SNMP Traps Time Synchronization with NTP server WWW and Security Web server and Security configuration Maintenance Factory defaults info etc Network Basic settings of the network interface IP address can be set as either static or obtained automatically by the DHCP server After saving the setting device will be rebooted automatically Before changing IP address please contact your network administrator Obtain an IP address automatically IP address Default gateway DNS server IP Standard subnet mask Subnet mask Periodic restart interval 192 168 1 213 192 168 1 1 192 168 1 1 255 255 2550 of e Apply settings Cancel changes 12 IE SNC Tx5xx 24 Alarm limits Fot each measurement channel is possible to set upper and lower limits time delay for alarm activation and hysteresis for alarm clearing Settings Alarm limits Configuration of the alarm limits The safe range is between high and low limit Alarm condition occurs General while measured value is out of the safe range for selected time delay Alarm is cleared if measured value General device settings returns to safe range with hysteresis Temperature limits Networ
13. synchronization it is necessary set IP 26 IE SNC Tx5xx 24 address to the SNTP server It is also possible set GMT offset for correct time zone Time is used in graphs and history CSV files Maximum jitter between two time synchronization is 90sec at 24 hours interval 27 IE SNC Tx5xx 24 Troubleshooting The chapter describes the common problems with devices Web Sensor Tx5xx and methods how to fix these problems Please read this chapter before you will call technical support I forgot the device IP address IP address is factory set to 192 168 1 213 If you had changed it and forgot new IP address run the TSensor software and press Find device In the window are displayed all available devices 1 can not connect to the device In search window is only IP and MAC address displayed Other details are marked N A This problem occurs if IP address of the device is set to another network Select the window Find device in TSensor software and press Change IP address Follow the software instructions To assign IP address automatically using DHCP server set the device IP address to 0 0 0 0 Device IP address is not displayed in window Find device In TSensor software menu press Help My device was not found in window Find device Follow the software instructions MAC addtess of the device can be found on product label The device is not found even after manually setting MAC address This problem occurs especially in case
14. COMET SYSTEM www cometsystem cz Web Sensor T0510 Web Sensor T4511 Web Sensor T3510 Web Sensor T3511 Web Sensor T3511P Web Sensor T7510 Web Sensor T7511 Web Sensor T2514 USER GUIDE IE SNC Tx5xx 24 O Copyright COMET System s r o Is prohibited to copy and make any changes in this manual without explicit agreement of company COMET System s r o All rights reserved COMET System s r o makes constant development and improvement of all its products Manufacturer reserves the right to make technical changes without previous notice Misptints reserved Manufacturer is not responsible for damages caused by using the device in conflict with this manual To damages caused by using the device in conflict with this manual can not be provided free repairs during the warranty period This user manual describes devices with firmware version 1 5 5 x For devices with older firmware versions 1 5 2 x and 1 5 3 x please read manual IE SNC Tx5xx 22 IE SNC Tx5xx 24 Table of contents I Fog cepa kite ERZE 4 Ge eral safety rules T P 4 Device description and important notle6s eee rte OO awa 5 Getinge Statted eM Wii 7 What ismeeded for Operation Gz X 7 Motinting the device RI 7 eee tete rien etenim tei OOOO ines 8 CHECKING D 10 ID6v
15. Pressure for quantities calculation is stored in device memoty Default value is 1013hPa and can be changed by software Range 0 to 550g kg Accuracy 2 1g kg at ambient temperature T 35 C 95 F Mixing ratio This value depends on atmospheric pressure Pressure for quantities calculation is stored in device memoty Default value is 1013hPa and can be changed by software Range 0 to 995g kg Accuracy 2 2g kg at ambient temperature T 35 C 95 F Specific enthalpy This value depends on atmospheric pressure Pressure for quantities calculation is stored in device memoty Default value is 1013hPa and can be changed by software Range 0 to 995kJ kg Accuracy 4kJ kg at ambient temperature T lt 25 C 77 F 37 IE SNC Tx5xx 24 Absolute humidity Range 0 to 400g m Accuracy t3g m at ambient temperature lt 40 C 104 F for more details see graph accuracy g m 20 0 20 40 60 80 100 process temperature T C Operating terms Temperature and humidity range in case with electronic 30 C to 80 C 0 to 100 RH no condensation It is recommended to switch off in temperature over 70 C Temperature and humidity range of external probe cable including T3511 P T7511 30 to 105 C 0 to 100 RH no condensation limited by graph Temperature of Pt1000 probe 14511 depends on probe model Protectio
16. Time synchronization enabled Network Basic settings of the network interface SNTP server IP address 192 168 1 2 Alarm limits GMT offset min 0 Configuration of the alarm limits NTP synchronization every hour Measuring Units display settings etc ly settings Cancel changes SOAP protocol i 2 Setup SOAP protocol for database system Emai I Alarm emails configuration Protocols Syslog and ModbusTCP protocol settings SNMP SNMPv1 protocol and SNMP Traps Time Synchronization with NTP server WWW and Securi Web server and Security configuration Maintenance Factory defaults info etc 17 IE SNC Tx5xx 24 WWW and security Security features can be enabled by the Security enabled option When security is enabled it is necessary to set administrator password This password will be required for device settings When secured access is required even to actual values reading it is possible to enable User account only for viewing enabled Port of the www server can be changed from the default value 80 using filed WWW port Web pages with actual values are refreshed according to Web refresh interval field mess Settings WWW and Security Security General 2 Configuration of the secure access to the device Administrator password must be inserted if security is General device settings enabled Administrator password is used for device configuration User password is used only for measured values vie
17. an be set via SOAP server target place Device send SOAP message according selected Sending interval Option Send SOAP message when alarm occurs sends message when an alarm on channel occurs or alarm is cleared These SOAP messages are sent asynchronously to selected interval Pittman Settings SOAP Setup SOAP protocol for database system Actual measured values are sent as XML files For more General information please read the user guide for database system General device settings SOAP protocol enabled Network Basic settings of the network interface SOAP server IP address 192 168 1 20 Alarm limits SOAP server port 80 Configuration of the alarm limits SOAP server target place http 192 168 1 20 soap Measuring Units display settings etc Sending interval 1 Min SOAP pO Send SOAP message when alarm occurs Email Alarm emails configuration Apply settings Cancel changes Protocols Syslog and ModbusTCP protocol settings SNMP SNMPv1 protocol and SNMP Traps Time Synchronization with NTP server WWW and Security curi Web server and Security configuration Maintenance Factory defaults info etc Email sending enabled option allows email features It is necessaty set address of the SMTP server into SMTP server address field Domain name for SMTP server can be used Default pott of the SMTP setver can be changed using item SMTP server port SMTP authentication can be enabled u
18. be read using SNMP General protocol When alarm on channel occurs a warning message Trap can be sent to selected IP addresses General device settings SNMP read community public Network Basic settings of the network interface Trap enabled 7 Alarm limits P n f the Trap recipien Alm IP address of the Trap recipient 1 192 168 1 20 IP address of the Trap recipient 2 192 168 0 15 Measurin Units tti etc pius a eri pic IP address of the Trap recipient 3 0 0 00 SOAP protocol Setup SOAP protocol for database system Apply settings Cancel changes Email Alarm emails configuration Protocols Syslog and ModbusTCP protocol settings SNMP SNMPv1 protocol and SNMP Traps ime Synchronization with NTP server WWW and Securi ity Web server and Security configuration Maintenance Factory defaults info etc Time Time synchronization with SNTP server can be enabled by Time synchronization enabled option IP address of the SNTP is necessaty to set into SNTP server IP address item SNTP time is synchronized at UTC format and due to be necessaty set corresponding time offset GSM offset min Time is synchronized every 24 hours by default Option NTP synchronization every hour decrease this synchronization interval to one hour Settings Time Time can be synchronized according the SNTP server To correct time is necessary set GMT offset of your General time zone General device settings
19. e and humidity measuring range is limited see graph below Operating temperature Accuracy Range Resolution of electronic m 0 6 C 30 to 80 C 0 1 C ni o o x o R 1 1 C22 to 176 F 0 2 F T4511 30 to 80 C 0 2 200 to 600 C22 to 176 F 0 4 F 225 to 999 F _ 02 13511 P 0 49C 30 to 105 C 0 1 C m 0 7 F C22 to 221 R 0 2 F Temperature response time with stainless steel sensor cover F5200 in air flow 1m s 13510 T3511 T7510 T7511 t90 lt 6min temperature step 20 C 36 F T3511P t90 lt 16min temperature step 20 C 36 F Temperature probe for Web Sensor T4511 Pt1000 3850ppm connected by shielded cable max length 10m Relative humidity measurement Temperature and humidity measuring range is limited see graph below Operating humidity of Accuracy Resolution electronic T3510 50 T7510 0 to 100 RH 29 a 0 to 100 RH i in range 5 to 95 RH 0 1 RH 13511 P without condensation 2 temperature compensated T7511 in 23 C 73 4 C Humidity response time with stainless steel sensor cover F5200 in air flow 1m s t90 lt 30s humidity step 65 RH constant temperature 35 IE SNC Tx5xx 24 Relative humidity and temperature restrictions 100 4 continuous use 50 oblast trval ho pou iti 40
20. een devices Probe has connector with protection IP67 Models marked TxxxxZ are custom specified devices Description of these devices is not included in this manual General safety rules The following summary is used to reduce the risk of injury or damage the device To prevent injury please follow instructions serviceable parts inside i The device can be services only by a qualified person The device contains no Don t use the device if it doesn t work correctly If you think that the device is not working correctly let check it by qualified service person IE SNC Tx5xx 24 It s forbidden to use the device without the cover Inside the device can be a dangerous voltage and may be risk of electric shock Use only the appropriate power supply adapter according to manufacturer specifications and approved according to relevant standards Make sure that the adapter does not have damaged cables or covers Connect the device only to network parts approved according to relevant standards Connect and disconnect the device properly Don t connect or disconnect Ethernet cable or probes if the device is powered The device may be installed only in prescribed areas Never expose the device to higher or lower temperatures than is allowed The device has not improved resistance to moisture Protect it from dripping or splashing water and do not use at areas with condensation Devices are not designed for locations with chemical
21. elative humidity alarm state Integer 1 3 6 1 4 1 22626 1 2 3 7 Computed quantity alarm state Integer 1 3 6 1 4 1 22626 1 2 3 8 Atmospheric pressure alarm state Integer 1 3 6 1 4 1 22626 1 2 4 1 3 6 1 4 1 22626 1 2 4 1 Temperature low limit Int 10 1 3 6 1 4 1 22626 1 2 4 2 Temperature high limit Int 10 1 3 6 1 4 1 22626 1 2 4 3 Relative humidity low limit Int 10 1 3 6 1 4 1 22626 1 2 4 4 Relative humidity high limit Int 10 1 3 6 1 4 1 22626 1 2 4 5 Computed quantity low limit Int 10 1 3 6 1 4 1 22626 1 2 4 6 Computed quantity high limit Int 10 1 3 6 1 4 1 22626 1 2 4 7 Temperature time delay Integer 1 3 6 1 4 1 22626 1 2 4 8 Relative humidity time delay Integer 1 3 6 1 4 1 22626 1 2 4 9 Computed quantity time delay Integer 1 3 6 1 4 1 22626 1 2 4 10 Temperature hysteresis Int 10 1 3 6 1 4 1 22626 1 2 4 11 Relative humidity hysteresis Int 10 1 3 6 1 4 1 22626 1 2 4 12 Computed quantity hysteresis Int 10 1 3 6 1 4 1 22626 1 2 4 13 Atmospheric pressure low limit Int X 1 3 6 1 4 1 22626 1 2 4 14 Atmospheric pressure high limit Int X 1 3 6 1 4 1 22626 1 2 4 15 Atmospheric pressure time delay Integer 1 3 6 1 4 1 22626 1 2 4 16 Atmospheric pressure hysteresis Int X 1 3 6 1 4 1 22626 1 5 5 1 0 SNMP Trap String 1 3 6 1 4 1 22626 1 5 6 1 1 1 nr Temperature history values Int 10 22 IE SNC Tx5xx 24 1 3 6 1 4 1 22626 1 5 6 1 1 2 nt Relative humidity history values Int 10 1 3 6 1 4 1 22626 1 5 6 1 1 3 nr Computed quant
22. f the Syslog server field Syslog server IP address Ue Settings Protocols ModbusTCP protocol General Configuration of the ModbusTCP protocol Actual measured values can be read using ModbusTCP protocol General device settings Modbus registers are described inside the user manual Network Modbus server enabled Basic settings of the network interface Modbus port 1502 Alarm limits Configuration of the alarm limits Syslog protocol Configuration of the Syslog protocol Alarm messages can be sent to the Syslog server using UDP Measuring protocol Units display settings etc Syslog enabled a SOAP protocol Setup SOAP protocol for database system Syslog server IP address 192 168 1 20 Email Alarm emails configuration Apply settings Cancel changes Protocols Syslog and ModbusTCP protocol settings SNMP SNMPv1 protocol and SNMP Traps Time Synchronization with NTP server WWW and Security Web server and Security configuration Maintenance Factory defaults info etc 16 IE SNC Tx5xx 24 SNMP For reading values via SNMP it is necessary to know passwotd SNMP read community SNMP Trap can be delivered up to three IP address IP address of the Trap recipient SNMP Traps ate sent at alarm or error state on the channel Trap feature can be enabled by option Trap enabled Settings SNMP Configuration of the SNMPv1 protocol and SNMP Traps Actual measured values can
23. f web pages For detailed informations please contact your distributor SMTP sending e mails When measured values are over the set limits the device allows send e mail to a maximum of 3 addresses E mail is send when alarm condition on the channel is cleared or a measuring error occurs It is possible to set repeat interval for email sending For correct sending of e mails it is necessary to set address of SMTP server Domain address can be used as SMTP server address too For proper function of DNS is required to set DNS server IP address SMTP authentication is supported but SSL STARTTLS not Standard SMTP port 25 is used by default SMTP port can be changed Contact your network administrator to obtain configuration parameters of your SMTP server E mail sent by the device can not be answered 21 IE SNC Tx5xx 24 SNMP Using SNMP protocol you can read actual measured values alarm status and alarm parameters Via SNMP protocol is also possible to get last 1000 measured values from history table Writing via SNMP protocol is not supported It is supported SNMPv1 protocol version only SNMP used UDP port 161 OID keys description can be found in the MIB table which can be obtained from device website or from your distributor The password for reading is factory set to public The changes can be made using TSensor softwate ot web interface OID keys Description
24. he XSD schema can be downloaded from http cometsystem cz schemas soapTx5xx_v2 xsd SOAP message example lt xml version 1 0 encoding utf 8 Xsoap Envelope xmlns soap http schemas xmlsoap org soap envelope xmlns xsi http www w3 org 2001 XMLSchema instance xmlns xsd http www w3 org 2001 XMLSchema gt lt soap Body gt lt InsertTx5xxSample xmlns http cometsystem cz schemas soapTx5xx v2 xsd gt lt passKey gt 13960932 lt passKey gt lt device gt 4145 lt device gt lt temp gt 1 4 lt temp gt lt relHum gt 91 9 lt relHum gt lt compQuant gt 0 3 lt compQuant gt lt pressure gt 9999 lt pressure gt lt alarms gt hi no no no lt alarms gt lt compType gt Dew point lt compType gt lt tempU gt C lt tempU gt lt pressureU gt n a lt pressureU gt lt timer gt 60 lt timer gt lt InsertTx5xxSample gt lt soap Body gt lt soap Envelope gt Element pem lt passKey gt Contains the device serial number an eight digit number lt device gt Device type identification number code Device Code DEC T3511 4107 T4511 4106 T7511 4129 4 4 4 T2514 12 T0510 144 T3510 145 T7510 4146 lt temp gt Contains the value of temperature a decimal part of number is separated by a dot Error on channel is signaled by 9999 or 9999 lt relHum gt Contains the value of relative humidity Error value 9999 or 9999 lt compQuant gt Contains the value of computed quantity
25. ice SEQUI conten tete reete eoe ae 11 Setup sing web rera Tree ME v ERN e 11 Setup usine TSensot SOWAT O O W 18 Factory 19 COMMUNICATION protocols 21 M R MN 21 SMTP sending e malls ette rr eer e rip e GO 21 dum E dd 22 hin nrMESi 23 SOAP 24 SYSLOG 26 S HM 26 Troubleshooting e MM HA 28 I fofgot the device IP address O AE 28 I can not connect to the device wsad awokado wdw 28 I forgot the password Bro dioi M 29 Pactory usa adu tatu So kin dn ksiadz utente Ue LT LIP HL TO TE ates 29 Display 18 ze 29 DEVICE CFTOE STAES 30 Technical le Seit s eria ona REM 77 31 DimMENSIO Se 31 General parameters w 33 Measured Values eO GR d 35 Temperature MEAs urs cesses KOSOWO R Ria 35 Relative hiimidity measurement a ai zak RABA GAR AiR ORA aa G aan RE 35 Atmospheric pressure meas retment
26. in Point 4 caused alarm At this moment were sent e mails traps and set alarm flag on website SNMP and Modbus The alarm lasted up to Point 5 when the temperature dropped below the set hysteresis temperature limit hysteresis At this moment was active alarm cleared and e mail sent When alarm occurs alarm messages will be sent In case of power failure or device reset e g changing the configuration will new alarm state evaluated and new alarm messages will be sent 13 IE SNC Tx5xx 24 Measuring Page contains settings of the measuring part of the device Settings can be saved only if jumper inside device is closed Fields in this page are shown according device type It is possible set visibility of measured values on device LCD Display can be switched off Units of measured and computed quantities are selectable by fields Temperature unit Computed value and Atmospheric pressure unit Devices without atmospheric pressure measurement have field Pressure value for computed values Here is required to set pressure for calculation of computed quantities Pressure compensation for altitude above sea level is possible via Atmospheric pressure offset This offset depends on current altitude This value is added to measured atmospheric pressure final value must be in range 300hPa to 1350hPa Settings Gener al General device settings Network Basic settings of the network interface Alarm limits Configuration
27. ity alarm state String 20496 0x5010 Atmospheric pressure low limit Int X 20497 0x5011 Atmospheric pressure high limit Int X 20498 0x5012 Atmospheric pressure hysteresis Int X 20499 0x5013 Atmospheric pressure alarm state String 20500 0x5014 Atmospheric pressure time delay DEC Type DEC BCD HEX String Int 10 Int X SOAP The device allows you to send currently measured values via SOAP v1 1 protocol The device sends values in XML format to the web server The advantage of this protocol is that communication is initialized by the device side Due to it is not necessary use port forwarding If the SOAP message can not be delivered warning message via SNMP Trap register is in range 0 4500 16bit register is in BCD format 16bit number in HEX format 16bit two characters in one 16bit register no no alatm hi value is lower than set limit lo value is higher than set limit register is in format integer 10 16 bits 125 12 5 C error 9999 ot 9999 register format depends on value type error 9999 hPa integer 10 9760 976 0hPa PSI integer 1000 14156 14 156PSI inHg integer 100 2882 28 82inHg mBar integer 10 9761 976 1mBar oz in integer 10 2265 226 50z in mmHg integer 10 7321 732 1mmHg inH O integer 10 3919 391 9inH O kPa integer 100 9761 97 61kPa 24 IE SNC Tx5xx 24 ot Syslog protocol is sent The file with t
28. ity history values Int 10 1 3 6 1 4 1 22626 1 5 6 1 1 4 nr Atmospheric pressure history values Int X When alatm occurred a warning messages trap can be sent to selected IP addresses Addresses can be set using TSensor software or web interface Traps are sent via UDP protocol on port 162 The device can send following traps Trap Description 0 0 Reset of the device 1 0 Settings was changed 6 0 Testing Trap 6 1 NTP synchronization error 6 2 SMTP server login error 6 3 SMTP authentication error 6 4 E mail sending error Some error occurred during SMTP communication 6 5 TCP connection to server cannot be opened 6 6 DNS error 6 7 SOAP file not found inside web memory 6 8 SOAP message MAC address can t be obtained from IP address 6 9 sending error TCP connection to server cannot be opened 6 10 Wrong response code from the SOAP server 6 11 6 14 Upper alarm on channel 6 21 6 24 Lower alarm on channel 6 31 6 34 Clearing alarm on channel 6 41 6 44 Measuring error Modbus TCP Device supports Modbus protocol fot communication with SCADA systems Device use Modbus TCP protocol TCP port is set to 502 by default Port can be changed using TSensor software ot web interface Only two Modbus clients can be connected to device at one moment Modbus device addtess Unit Identifier can be arbitrary Modbus write command is not suppor
29. jumper and push button inside device during connecting power supply Factory parametets settings Parameter pes value SMTP setver address example com SMTP server port 25 Alarm email repeat sending interval off Info email repeat sending interval off Alarm and Into emails attachment off E mail recipients addresses cleared E mail sender sensor IP SMTP authentication off SMTP user SM TP password cleared E mail sending enabled off IP addresses SNMP traps recipients 0 0 0 0 Password for SNMP reading public Sending SNMP Trap off Website refresh interval sec 10 Website enabled yes Website port 80 Security off Administrator password cleared User password cleared Modbus port 502 Modbus server enabled yes History storage interval sec 60 SOAP server IP address 0 0 0 0 SOAP server port 80 SOAP server target place cleared 19 IE SNC Tx5xx 24 SOAP sending interval sec 60 SOAP message when alarm occurs yes SOAP protocol enabled off Syslog server IP address 0 0 0 0 Syslog protocol enabled off SNTP server IP address 217 31 205 226 GMT offset min 0 NTP synchronization every hour off SNTP synchronization enabled off MTU 1400 Periodic restart interval off Demo mode off Temperature High limit 50 Low limit Hysteresis 1 Time delay sec 30 Relative humidity High
30. k Actual value 21 8 C Basic settings of the network interface High limit Low limit C Hysteresis C Time delay sec Alarm limits Configuration of the alarm limits 50 0 0 0 1 0 30 Measurin A p Units display settings etc Relative humidity limits Actual value 66 3 RH SOAP a High limit RH Low limit RH Hysteresis RH Time delay sec 80 0 20 0 1 0 30 Email Alarm emails configuration Dew point limits Actual value 15 3 C Protocols Syslog and ModbusTCP protocol settings High limit Low limit C Hysteresis C Time delay sec SNMP 50 0 0 0 1 0 30 SNMPv1 protocol and SNMP Traps Time Atmospheric pressure limits Synchronization with NTP server Actual value 96 09kPa WWW and Securi High limit kPa Low limit kPa Hysteresis kPa Time delay sec Web server and Security configuration 100 00 70 00 1 00 30 Maintenance Factory defaults info etc Apply settings Cancel changes Example of setting the limit to the upper alarm limit temp limit high hysteresis gt temp Time delay time In Point 1 the temperature exceeded the limit From this time the time delay is counting Because at point 2 the temperature dropped below the limit value before the time delay expired alarm was not set In Point 3 the temperature has risen over limit again During the time delay the value does not drop below the set limit and therefore was
31. l the latest version of TSensor software This software is used to all device settings TSensor software can be free downloaded from the manufacturer s website Software can be also supplied on CD Device configuration can be made using web interface For web configuration is not TSesnor software necessary contact your network administrator to obtain following informations for the connection to the network IP address Default gateway DNS serer IP Subnet mask IE SNC Tx5xx 24 e check if there is no IP address conflict when you connect the device into network for the first time The device has from factory set the IP address to 192 168 1 213 This address must be changed according to informations from the previous point When you installing several new devices connect them to the network one after another e connect probe Pt1000 to Web Sensor T4511 e connect the Ethernet connector e connect the power adapter 9 30V e g 12V 200mA e LEDs on LAN connector should blink after connecting the power and LCD start showing measured values Web Sensor 10510 T3510 T7510 T2514 T3511 D T7511 B Ethernet v Device settings e run configuration software TSensor on your PC e switch to an Ethernet communication interface e press button Find device IE SNC Tx5xx 24 Communication Settings X Communication interface Device settings a Service cable SPO03 IP address 21681213 1581 21 21681213
32. limit 80 Low limit 20 Hysteresis 1 Time delay sec 30 Computed quantity High limit 50 Low limit Hysteresis 1 Time delay sec 30 Atmospheric pressure High limit 1000 Low limit 700 Hysteresis 12 Time delay sec 30 Device name Web Sensor 20 IE SNC Tx5xx 24 Communication protocols Short introduction to communication protocols of the device To use some communication protocols is necessary software which can use the protocol This software is not included For detailed description of protocols and application notes please contact your distributor Website The device supports displaying of measured values history graphs and configuration using web browser History graphs are based on HTML5 canvas Web browser must support this feature for proper function of graphs Firefox Opera Chrome or Internet Explorer 9 can be used If the device has IP address 192 168 1 213 type into your browser http 192 168 1 213 Using TSensor software or web interface can be set automatic webpages refresh in interval The default value is 10sec Actual measured values can be obtained using XML file values xml Values from history can be exported in CSV format History storage interval can be set using TSensor software or web interface History is erased after every reboot of the device Reboot of the device is performed when the power supply is disconnected and also after configuration change The device allows you to customize the design o
33. ly aggressive environment Temperature and humidity sensors must not be exposed to direct contact with water or other liquids It is not allowed to remove the sensor cover to avoid any mechanical damage of the sensors Before you removing probe of the Web Sensor Tx5xxP make sure that pressure in a pressure chamber and ambient pressure are equal Don t use device in explosive environments Don t stress the device mechanically Device description and important notices This chapter contains informations about basic features Also there are important notices concerning to functional safety Measured values can be displayed on LCD display or can be read using an Ethernet connection The following formats are supported e Web pages with user changeable look and XML files e Modbus TCP protocol e SNMPv1 protocol e SOAP protocol The device can also be used to check measured values and if the limit is exceeded device sends warning messages Possible ways to sending warning messages e Sending e mails up to 3 e mail addresses e Sending SNMP traps up to 3 configurable IP addresses e Displaying the alarm status on web page e Sending messages to Syslog server The device setup be made by the TSensor software or web interface TSensor software can be free downloaded from the manufacturer s website Also you will find there latest IE SNC Tx5xx 24 firmware for yout device Do not upload to your device firmware which is not designed
34. n IP30 case with electronic IP40 temperature humidity probe T3511 T3511P T7511 Operating pressure range of probe T3511P up to 25bar Air flow velocity around T3511P probe up to 25m s at pressure of 1bar 1m s at a pressure of 25bar Other environmental conditions external influences according to HD 60364 5 51 normal 38 IE SNC Tx5xx 24 Working position T2514 T3511 P T4511 T7511 arbitrary Working position T0510 T3510 T7510 with sensor cover downwards When mounting in RACK 19 with universal holder MP046 optional accessories then sensor cover can be placed horizontally End of operation Disconnect the device and dispose it according to current legislation for dealing with electronic equipment Electronic devices must be professionally destroyed in accordance with EU Directive 2002 96 ES of 27th January 2003 Technical support and service Technical support and service is provided by distributor Contact is included in warranty certificate Preventive maintenance Make sure the cables are not damaged periodically We recommend you periodic calibration for measurement accuracy validation Recommended calibration interval Calibration interval T0510 2 yeats T3510 1 year 17510 1 year T2514 1 year 13511 P 1 year T4511 2 years T7511 1 year 39 IE SNC Tx5xx 24 Optional accessories This chapter contains list of optional accessories which can be ordered by e
35. needed For information about SMTP server settings please contact your network Configuration of the alarm limits administrator or ISP Measuring SMTP server address smtp example Units display settings etc SMTP server port 25 SOAP protocol E Setup SOAP protocol for database system SMTP authentication Username sensor example com Alarm emails configuration Password Protocols Syslog and ModbusTCP protocol settings Email configuration Setup up to three address for email recipients Sender address is usually the same as the username of SNMP the SMTP authentication SNMPv1 protocol and SNMP Traps Email sender address sensor example com Rime re Synchronization with NIP server Recipient 1 admin company com WWW and Securi Recipient 2 il Web server and ext Ete i Recipient 3 Maintenance Factory defaults info etc Short email Alarm email repeat sending interval 1 Hour Info email sending interval 1 Hour iv Alarm and Info emails attachment Export comma csv v Apply settings Apply and test Cancel changes Modbus a Syslog protocols ModbusTCP and Syslog protocol settings are configurable via menu Protocols Modbus is enabled by default Deactivation is possible via Modbus server enabled option Modbus port can be changed via Modbus port field Syslog protocol can be enabled using item Syslog enabled Syslog messages are sent to IP address o
36. nged then insert http 192 168 1 213 Displayed web page lists actual measured values If the web pages are disabled you can see text Access denied In the case of measurement error a text Error is shown instead value 10 IE SNC Tx5xx 24 Device setup This chapter describes basic device configuration There is a description of settings using web interface Setup using web interface Device can be setup using web interface or TSensor software Web interface can be managed by the web browser Main page will be shown when you insert device address into address bar of your web browser There you find actual measured values Page with history graphs is shown when you click to tile with actual values Access to device setup is possible via tile Settings Cj Web Sensor x W 192 168 1 213 Web Sensor Time 11 55 10 2013 04 02 s n 11963408 Temperature Relative humidity 24 6 C 65 2 RH alarm none alarm none Dew point Atmospheric pressure Refresh 17 6 C 96 30kPa page alarm none alarm none Copyright 2013 Comet system s r o All rights reserved 11 IE SNC Tx5xx 24 General Device name can be changed using item Device name Measured values ate stored into memory according History storage interval field After changing of this interval all history values will be cleared Changes must be confirmed by Apply settings button EMS min meu Settings General device settings Network Basic settings of the
37. ntact the distributor 30 IE SNC Tx5xx 24 Technical specifications Informations about technical specifications of the device Dimensions Web Sensor T0510 39 5 mm 73 mm 15mm y Web Sensor T2514 40 mm 73 mm IE SNC Tx5xx 24 Web Sensor T3510 T7510 89 mm 76 5 mm 148 mm Web Sensor T3511 P T7511 32 73 mm IE SNC Tx5xx 24 Web Sensor T4511 40 mm 73 mm 04 3 mm General parameters Supply voltage DC voltage from 9V to 30V coaxial connectot 5x2 1mm diameter positive pole in the middle Consumption 1W depending on the operating mode Measuring interval 2sec Display switching interval 4sec when more than two values are displayed Not allowed manipulations It is not allowed to operate the device under conditions other than specified in technical parameters Devices are not designed for locations with chemically aggressive environment Temperature and humidity sensors must not be exposed to direct contact with water or other liquids It is not allowed to remove the sensor cover to avoid any mechanical damage of the sensors Case material ABS Material of T3511P probe duralumin with the black eloxal surface finish Mechanical connection of probe T3511P G1 2 with O ring Weight 33 IE SNC Tx5xx 24 12514 130g T0510 145 T4511 145g 13510 155g
38. s when the IP address of the device belongs to another network and also Subnet mask or Gateway are incorrect In this case is DHCP server in the network necessary In TSensor software menu press Help My device was not found in window Find device As new IP address set 0 0 0 0 28 IE SNC Tx5xx 24 Follow the softwate instructions An alternative is to teset device to factoty defaults using factoty defaults button I forgot the password for setup Please reset device to factory defaults Procedure is described at following point Factory defaults This procedure restore device to factory settings including network parameters IP address Subnet mask etc Settings relating to measurement are not restored by factory defaults For factory defaults follow these steps disconnect the power supply unsctew uppet cover of the device case close the jumper inside device press button inside device and power on device at same time keep the button pressed for 10 sec button em jumper close the device Display is off Check if power supply is connected Disconnect power connector and connect connector again watch the display at the moment of connecting the power If all LCD segments light for 1 second and go out again the display is turned off by software 29 IE SNC Tx5xx 24 Device error states Device still make self tests If error occurred LCD shows error codes LCD display Description Error 0 Erro
39. sing SMTP authentication option When authentication is enabled Username and Password must be set For successfully email sending it is necessary insert Email sender address This address is usually same as username of the SMTP authentication Into fields Recipient 1 to Recipient 3 it is possible set address of email recipients Option Short email enable sending emails in short format This format is usable when you need to forward emails into SMS messages When option Alarm email repeat sending interval is enabled and there is active alarm on channel then emails with actual values ate sent repeatedly Info email sending interval option enables sending emails at selected time interval CSV history file can be sent together with the repeat info emails This feature can be enabled by Alarm and Info emails attachment option It is possible to test email function using button Apply and test This button save a new settings and send a testing email immediately 15 IE SNC Tx5xx 24 Sus Settings Email Configuration of the alarm emails Device can send warning email when alarm on measured channel General occurs Email is also sent when alarm condition is cleared General device settings Email sending enabled Network Basic settings of the network interface SMTP server configuration For proper email sending it is necessary to setup connection to your SMTP server SMTP authentication Alarm limits can be used if
40. ted Specification and description of the Modbus protocol is free to download on www modbus org Supported Modbus commands functions Command Code Description Read Holding Register s 0x03 Read 16b register s Modbus device registers Address could be by 1 higher depending on type used communication library Address DEC Address HEX 49 0x0031 Measured temperature Int 10 50 0x0032 Measured relative humidity Int 10 51 0x0033 Measured computed quantity Int 10 52 0x0034 Measured atmospheric pressure Int X 4149 0x1035 Serial number high BCD 4150 0x1036 Serial number low BCD 4151 0x1007 Device type HEX 20481 0x5001 Temperature low limit Int 10 20482 0x5002 Temperature high limit Int 10 20483 0x5003 Relative humidity low limit Int 10 23 IE SNC Tx5xx 24 20484 0x5004 Relative humidity high limit Int 10 20485 0x5005 Computed quantity low limit Int 10 20486 0x5006 Computed quantity high limit Int 10 20487 0x5007 Temperature hysteresis Int 10 20488 0x5008 Temperature time delay DEC 20489 0x5009 Relative humidity hysteresis Int 10 20490 0x500A Relative humidity time delay DEC 20491 0x500B Computed quantity hysteresis Int 10 20492 0x500C Computed quantity time delay DEC 20493 0x500D Temperature alarm state String 20494 0x500E Relative humidity alarm state String 20495 0x500F Computed quant
41. ure n file write FOpen soap log a FWrite file write data FClose file write server new SoapServer null array uri gt http test uri server gt addFunction InsertTx5xxSample server gt handle gt Syslog The device allows sending text message to selected Syslog server Events are send using UDP protocol on port 514 Syslog protocol implantation is according to RFC5424 and RFC5426 Events when Syslog messages ate send Sensor fw 1 5 5 x Reset of the device Settings changed Settings was changed NTP synchronization error N IP synchronization error Testing message Test Syslog message Email login error E mail sending error Email auth error Email some error Email socket error Email dns error SOAP file not found SOAP message sending error SOAP host error SOAP sock error SOAP delivery error Text XXXX is set according channel type Temperature Relative humidity Specific humidity Mixing proportion Specific enthalpy Atmospheric pressute High alarm XXXX Upper alarm on channel Low alarm XXXX Lower alarm on channel Clearing XXXX alarm Clearing alarm on channel Error XXXX Measuring error SNTP The device allows time synchronization with NTP SNTP server SNMP protocol version 3 0 is supported RFC1305 Time synchronization is made every 24 hours Time synchronization every hour can be enabled For time
42. wing Network Basic settings of the network interface Security enabled Alarm Administrator username admin Configuration of the alarm limits Administrator password nae Measuring Units display settings etc Confirm Administrator password eesse SOAP protocol User account only for viewing enabled v Setup SOAP protocol for database system User username user Email Alarm emails configuration User password Protocols Syslog and ModbusTCP protocol settings Confirm User password SNMP web server SNMPv1 protocol and SNMP Traps Configuration of the embedded web server After web port changing device will be rebooted with new port Time Web server enabled Synchronization with NTP server WWW port 80 WWW and Security Web server and Security configuration Web refresh interval 10 Sec Maintenance Factory defaults info etc E Apply settings Cancel changes Setup using TSensor software TSensor software is an alternative to web configuration Some less important parameters are configurable only by the TSensor software TSesnor software allows user adjustment of measuted values Parameter MTU size can reduce size of the Ethernet frame Lowering of this size can solve some communication problems mainly with Cisco network infrastructure 18 IE SNC Tx5xx 24 Factory defaults Factory defaults field set the device into factory configuration Network parameters IP address
43. xtra cost Manufacturer recommends using only original accessories Temperature probe Pt1000 for Web Sensor T4511 Wide ranges of Pt1000 3850ppm probes are available as optional accessories Please contact your local distributor to help you with choice of correct probe according your application Power supply Adapter A1515 Power supply adapter with CEE 7 plug 100 240V 50 60Hz 12V DC 0 5A for Web Sensot devices Device case holder for RACK 19 MP046 MP046 is a universal holdet for mounting of Web Sensor devices into RACK 19 Probes holder for RACK 19 MP047 Universal holder for easy mounting probes in RACK 19 Flow chamber SH PP for Web Sensor T3511P Flow chamber for compressed air measurement up to 25 bars Made from stainless steel DIN 1 4301 inlet and outlet connection G1 8 thread for humidity probe connection G1 2 40 www cometsystem cz