Home
VITO® X1
Contents
1. Contents h Introduction General Notes Legal information Safety guidelines symbol explanation VITO X1 delivery contents VITO X1 Overview VITO X1 utilization Preparation before use CO O N O G Bb W N Filtration process k O Storage mh mh Maintenance and Service N Filtration process Go Accessories mb N Waste disposal Ol Storage recommendations for filters k O Troubleshooting VITO X1 technical data Declaration of conformity h O CO N Your notes tastes 3 if O O Ga Oo A AK A A II 1 44 mk nk d i O 01 A W W ND ND gt Serbosel durable 1 Introduction Dear VITO customer thank you for choosing this product by SYS Systemfiltration GmbH Please read the manual carefully to familiarize yourself with the handling of your VITO filtration system to ensure proper use Your local dealer and the customer service are available to answer your guestions and provide support We are grateful for comments and suggestions concerning the VITO filtration system and or the manual Please see contact information contained in this manual We hope that you enjoy your VITO oil filter system for a long time and increase the efficiency in your establishment With VITO you own a high quality oil filter system from which you can expect a long life and efficient suppor
2. N 6 2 Product description Lancetube quick connector Lancetube quick connector opened Connecting Piece Tank Seal Filterbasket inflow bottom Filter basket inflow top Filter basket handles Filter basket Particle filter Turbine intake Oil level sensor 13 VITO oil filter system 14 15 16 17 18 19 20 21 22 23 24 25 E Gullood AWARDS WINNER g VITO X1 User Manual 7 VITO X1 utilization 7 1 Designated use e VITO is designed for commercial use Follow the safety instructions Filtration is only possible if the oil is liquid VITO should only be used by suitably trained staff o VITO oil filter system is designed for intermittent duty 7 2 NON designated use The nonobservance of the contents described in the manual can lead to damage or malfunction of VITO or can lead to severe human injuries e VITO is NOT approved for cleaning filtering of liquids other than frying oil shortening Do NOT use or store VITO outside It will be damaged by rain humidity or cold e VITO is NOT designed for continuous duty Risk of overheating fire hazard Do NOT cover vent slots Do NOT touch the power plug with wet hands Do NOT jam or bend the power cord e The use of VITO is strictly prohibited for children VITO must not be operated on a connection other than protection class grounded No liability will be accep
3. tel AWARDS durable WINNER
4. Preparation Make sure that VITO is cooled down Open the top cover 10 Dispose particle filter 23 See 14 2 Manual or machine cleaning of the filter basket 22 and top cover 10 Clean the remaining parts of the unit Make sure that you clean the VITO considering the HACCP rules or your own country regulations H MG N 11 3 Manual Cleaning 1 Clean the control panel lever switch ect with a damp cloth DO NOT use running water because this will harm the electrical system of the device 2 Clean remaining parts with soapy water 3 Dry VITO with a towel 11 4 Machine cleaning 1 1 Put filter basket 22 and cover 10 into the dishwasher 2 2 Start cleaning program 3 3 Clean the control panel with a cloth te ones hos OK 3 saa ON ER seele o ce eco PTT LETY 8 TTL Seer gt seseesesee 04 TT ILI SE 1155595 EM 202004006 LELET VELEL E T Lasteg 12 12 Particle Filter Change Change the particle filter 23 only if necessary The time of change is based on usage of VITO and the degree of pollution of the frying oil e The filter has to be changed when there is no performance or the filter is full Don t leave gaps between the filter and Filter full the edges of the filter basket Filter empty 13 Accessories Additional accessories for your VITO are available Spare filters for VITO X1 VITO Oiltester bundle size 1 Box 50 Pcs Checks TPM of y
5. lance 12 in the lance tube 6 Plug out VITO 9 5 Starting the pumping back process 1 Place VITO securely next to the fryer 2 Make sure that the switch Q5 is on position OFF 3 Put the lance 12 into the fryer and hold it tight or ensure a secure hold 4 Plugin VITO Power indicator red LED 02 is active 5 First turn the switch lever 01 and then turn the switch 05 to position Return 6 Indicator Return green LED 04 is lit during the pumping back process 9 6 Finishing the pumping back process prematurely 1 Take the lance 42 out of the oil 2 Let the pump process continue for 10 second and switch the lever 01 once to Extract and back to Return Caution At the end of the back pumping process air escapes out of the lance which may lead to bubbles and the resultant splashing Turn the switch 05 to position OFF Clean the lance 12 with a cloth Insert the lance 42 in the lance tube 08 for storage Plug out VITO 9 a E So e 10 Storage DO NOT put VITO into a cold storage room Condensation will destroy the electric parts 11 Maintenance and Service 11 1 Important Notes e Clean the tank 17 the sensor 25 and filter basket 22 carefully every time you change the particle filter 23 e Clean VITO only when the machine is cold DO NOT use abrasive cleaners DO NOT use a wire brush or similar e Unscrew the power cord only in case of service 11 2 Cleaning
6. or as a whole without the written permission of SYS Systemfiltration GmbH is prohibited 4 Safety guidelines symbol explanation Wrong treatment of the VITO can lead to dangers and injuries The following should be observed Potential dangers are marked with these signs Warning Danger of injury if this is not observed Danger of slipping Caution A if oil is spilled to the floor Important security tip Risk of electric shock by incorrect use or case opening Danger of burnings Operating instruction for the user of VITO by incorrect application Information about the handling of VITO oil filter system Danger of hearing disorder for the user of VITO X1 Protection class 1 Use the VITO X1 only in grounded conditions 5 VITO X1 delivery contents e VITO X1 e Power cord e Lance with tube and quick release fastener Cover e Filter basket Manual Warranty card Short instruction e Particle filter 1 piece e Inbus key e Wrench ely Serbobal 1 B if tastes 3 aur ble Page 6 01 02 03 04 05 06 07 08 09 10 11 12 VITO X1 Overview 6 1 Product description Switch lever Return Extract Power indicator red LED Extract blue LED Return green LED Rotary switch Return Off Extract Power Chord Con nector Heat Vents Lancetube removable Side handles Top Cover with handle Front Handle Lance with handles A 4
7. f VITO brand ed products that are sold in the EU You can return these products to local collection points 15 Storage recommendations for filters During storage do not expose the particle filters to extreme temperature or humidity for example near a heat source air conditioning or direct sunlight Heat cold and humidity have a negative effect on the properties of the parti cle filter especially after removing or opening the bag packaging In any case the particle filter must not be exposed to frost as this can cause damage to the microstructure of the filter which impairs the functionality of the particle filter Store dry at 60 65 relative humidity Room temperature 24 C 59C 78 F 40 F Do NOT put weight on pallets and filter parcels ely Serbobal 1 B if tastes 3 dura ble Avoid sudden temperature changes Store in the cardboard packaging in sealed bag Maximum height of the filter stack 185cm 6 ft on pallet Under observance of the above conditions the storage period will be 3 years 16 Troubleshooting Power indicator red LED Mains plug not Plug in VITO stays inactive plugged in Mains cable is defec Please contact service tive fuse is defective Please contact service VITO makes loud noises e Pump or turbine e Please contact service during filtration defective One of the lights is not lit but LED defective e Please contact service device can still be s
8. here is no vacuum created Til 9 2 Operation Notes apron gt The filtration process and the back pumping process can be interrupted anytime by turning the switch 05 to OFF Do NOT move VITO while filtration is in progress Only use VITO in a straight position Do not operate VITO without the filter basket Device may be damaged s The Power indicator red LED 02 is depending on what is chosen Re turn green LED 4 04 Extract blue LED 03 are lit during filtration process Starting the suctioning process Place VITO securely next to the fryer Make sure that the switch Q5is on position OFF Put the lance 12 into the fryer and hold it tight or ensure a secure hold Plug in VITO Power indicator red LED Q2 is active First turn the switch lever 01 and then turn the switch 05 to position Extract Indicator Extract blue LED 03 is lit during the suctioning process If switch Q5 is in position Extract and blue light 03 is not lighted the oil level sensor 25 is active gt Return oil to fryer See point 9 5 Pumping back process or see point 11 1 how to clean the oil level sensor 25 ely Serbobal 1 B if tastes 3 aur ble 9 4 Finishing the suction process prematurely 1 Take the lance 12 out of the oil 2 Let the suctioning process continue for 10 seconds 3 Turn the switch 05 to position OFF 4 Clean the lance 12 with a cloth 5 Store the
9. our oil Material cellulose e Prevents changing oil too early Ensures high quality e Quick temperature check Need something else Contact us for other solutions Our costumer support will gladly assist you with all your questions 14 Waste disposal 14 1 Packaging disposal The packaging should be recycled or e Store the packaging carefully 14 2 Filter disposal e Used filters must be disposed according to the local regulations 14 3 Device disposal If VITO reaches the end of its life cycle it must be disposed accordingly This disposal is handled by SYS Systemfiltration GmbH as defined by law Send VITO to SYS Systemfiltration GmbH Eltastrasse 6 78532 Tuttlingen Germany For further questions please contact your local dealer or the SYS customer support 14 4 WEEE Waste Electrical and Electronic Equipment Statement To protect the global environment and as an environmentalist SYS System filtration GmbH must remind you that Under the European Union EU Di rective on Waste Electrical and Electronic Equipment Directive 2002 96 EC which takes effect on august 13 2005 products of electrical and electronic equipment cannot be discarded as municipal waste anymore and manufac turers of covered electronic equipment will be obligated to take back such products at the end of their useful life Systemfiltration will comply with the product take back requirements at the end of the life cycle o
10. t for your work 2 General Notes This user manual contains important information about the handling of the VITO X1 Please read this document carefully and before using your VITO X1 Keep this manual easy available for more informa tion VITO X1 is an oil filtration system designed for the cleaning of frying oil shortening Frying will contaminate the oil with burned particles VITO X1 makes it possible to clean the oil straightly out of the fryer Filtering with VITO X1 prolongs the lifetime of the oil We recommend filtration with VITO X1 once or twice a day The VITO X1 particle filter can be used several times before it has to be changed As soon as the oil can t be vacuumed anymore or the filter basket for the particles is full the content should be disposed according to local regulations 3 Legal information SYS Systemfiltration GmbH Eltastrasse 6 78532 Tuttlingen Germany Phone 49 0 7461 96289 0 Fax 49 0 7461 96289 12 info VITO ag www VITO ag CEO Chief Operating Officer Andreas Schmidt MBA Dipl Wirt Ing Office ofthe company Tuttlingen Trade register entry Stuttgart HRB 451136 In cooperation with University Albstadt Sigmaringen Germany Industrial engineering with business studies Jakobstrasse 1 72458 Albstadt Germany Copyright SYS Systemfiltration GmbH All rights reserved This document is protected by copyright of SYS Systemfiltration GmbH Any reproduction in part
11. tarted VITO cannot be started Control unit defective Please contact service Line fuse Ground fault Net protection or other Please contact service circuit interrupter GFCI electronic components blowout are blocking Low back pumping Pump blocked Clean performance Pump defective Please contact service Tube blocked Tubing blocked No or too little vacuum flow Particle filter is Change particle filter blocked Particle filter is full Change particle filter Filter basket is full Empty the filter basket to much space Position the cover correctly between cover and the tank pipe is blocked Clean Particles in the filtred oil No filter inserted Insert filter Filter inserted Insert filter as described in incorrectly the manual No extraction and blue LED Oil level sensor dirty Change filter off Max oil level reached Clean Filter defect Return the oil and try again Should other issues appear get in contact with the customer support or your local dealer Contact details on chapter 3 Legal information 17 VITO X1 technical data Nominal voltage 220 240 V 10 According to country see type sign 50 bis 60Hz 100 120 V 10 50 60Hz under load approx 10 51 A bei 115 V Dimensions W x H x L 610 x 450 x 890mm 24 02 x 17 72 x 35 04in Storage temperature 0 C 50 F to max 30 C 86 F Perfect for e g 4 x 201 max 801 ely ne Serbotel durable E B tastes 3 18 Declara
12. ted for improper use 8 Preparation before use 8 1 Safety Guidelines Clean VITO before using it the first time Make sure that the local voltage is conform to IN the voltage on the type label of VITO _ Do NOT get the power cord in contact with hot oil shortening The maximum operating temperature is 175 C 347 F oil temperature Do NOT run the pump without oil Pay attention to heating elements grids or thermal sensors in the fryer Check the function of the oil level detection To lift or transport VITO only pick it up using the black side handles Use ear muffs or proper hearing protection e Use safety gloves e DO NOT RETURN THE OIL WITHOUT PLACING THE LANCE INTO THE FRYER 8 2 Storage of VITO Allowed ambient storage temperature 10 to 35 C 50 to 95 F 9 Filtration process 9 1 Requirements 1 Insert the filter basket 22 into the tank Filter basket 22 inflow bottom 19 must be plugged into connecting piece 16 inside the tank Place the particle filter 23 in the filter basket 22 See chapter 12 Particle filter change Check if the seal 18 is completely all around the machine covered by the filter basket 22 Put the top cover 10 on the X1 and pay attention to the correct seat ing Make sure that the lance tube quick connector 13 fits well Operation without a proper set up of the filter basket 22 and correctly placed top cover 10 Is not possible t
13. tion of conformity Issued by SYS Systemfiltration GmbH Eltastrasse 6 78532 Tuttlingen Germany for the product VITO X1 international patent pending The professional fat filtration equipment is manufactured and tested according to the following standards For the purposes of the EC Machinery Directive 89 392 EEC as amended by Directive 98 37 EC and developed in terms of the new Directive 2006 42 EC were designed and manufactured This declaration applies to all identical copies of the product The following harmonized standards are applied DIN EN 292 Safety of machinery equipment and facilities DIN EN 60204 1 electrical equipment for industrial machinery The product mentioned above meets the following basic requirements that laid down in Council Directive on the approximation of the laws of the member states relating to electromagnetic compatibility 2004 108 EC The following standards are applied EN 55014 1 2006 electromagnetic compatibility electromagnetic interference EN55014 2 1997 A1 2001 electromagnetic compatibility immunity EN 61003 2 2006 devices with analog inputs limits devices lt 16A EN 61003 3 2008 voltage fluctuation devices lt 16A Tuttlingen October 22 2013 F Andreas Schmidt CEO Chief Executing Officer SYS Systemfiltration GmbH 19 Your notes R Lasley 3 il 19 Your notes 19 Your notes R Lasley 3 il Zn Gul bod ser