8" QuickPanel View & Control User`s Manual Fully Loaded Color
Contents
1. 5 To save the settings run Backup see page 2 11 GFK 2507 Chapter 2 Overview 2 9 To configure a Proxy server 1 Start Pocket Internet Explorer 2 From the Tools menu choose Options The Internet Options dialog box appears Internet Options Address MyProxy com Port feo Bypass proxy server for local addresses 3 On the Connection tab select the Access the Internet using a proxy server check box 4 Inthe Address box type the URL of your proxy server see your ISP or network administrator 5 In the Port box type the server s port number for HTTP access Select the Bypass Proxy for Local Addresses check box to connect directly to sites like your intranet 7 Tap OK 8 To save the settings run bal Backup see page 2 11 2 10 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Backup Backup saves changes that you make to the Windows Registry or Desktop to Flash memory This utility is required because the QuickPanel View Control is not battery powered Specifically Backup does the following It stores the Windows CE registry including any control panel settings in Flash memory ltstores any changes or additions made to the Windows subtree of the file system in the user block of FLASH memory Run Backup whenever you make configuration changes to the operating system or installed applications and prior to shutting down the Q
2. QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Disconnect the power from your DC power supply before opening the QuickPanel View Control Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions when accessing the interior of the QuickPanel View Control Do not allow conductive material liquid or solid to contact the electronics of the QuickPanel Battery Power Connector GFK 2507 Chapter 4 Detailed Operation 4 45 To remove the internal battery 1 Disconnect power from the DC supply 2 Open the rear access panel 3 Release the battery by gently lifting it from the completely exposed side past the small protrusions To avoid breaking the battery retainer clips do not apply excessive upward pressure 4 Slide the battery out of its carrier noting the arrow on the carrier indicating the direction of removal To install a new battery 1 Disconnect power from the DC supply 2 Open the rear access panel Note Battery must be installed with positive side up 3 To install the battery insert one side of battery into upper side of battery clip then press other side into clip until snaps into place Waming Replace battery with Panasonic BR2032 only Use of another battery may present a risk of fire or explosion Battery may explode if mistreated Do not recharge disassemble or dispose of in fir
3. 12C Bus Chapter 2 Overview Touch Screen Accelerator Controller XScale PXA255 Backlit LCD Display Backlight Monitor COM2 RS232 9 pin COM1 25 pin RS232 RS485 Ethernet Port RJ45 Ethernet Controller CF Card Controller CF Card Slot USB Controller USB Port 1 USB Port 2 2 5 QuickPanel View Control Software Windows CE Microsoft Windows CE is the operating system for the QuickPanel View Control It is a full 32 bit O S with a graphical user interface This operating system is finding widespread application in hand held PCs and embedded controllers such as the QuickPanel View Control The familiar look and feel of Windows CE shortens the learning curve for users having experience with Windows 95 98 NT 2000 ME XP From a software developer s perspective the CE environment is a subset of the WIN32 application programming interface simplifying the porting of existing software from other versions of Windows The QuickPanel View Control operating system is stored in a 16 MB block of FLASH memory and copied to a block of DRAM for execution The operating system starts automatically following a power up or reset of the QuickPanel View Control For more on Windows CE visit www microsoft com windows embedded windowsce default mspx 2 6 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Working with Windows CE Although the main user in
4. General Memory Device Mame Copyrights J These settings are used to identify your A amp E Windows CE device to other computers Please type a name without any spaces and a short description Device name AMES Device description JQuickFanel Control 2 Onthe Device Name tab in the Device name box type a unique name for your QuickPanel View Control In the Device description box type a description 3 Tap OK 4 Inthe Control Panel double tap ga Owner The Owner Properties dialog box appears Owner Properties Identification Motes Network ID Window s CE uses this information to gain access to network resources Enter the user name password User and domain provided by your Password network administrator Domain 4 30 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 5 On the Network ID tab type your User name Password and Domain 6 Tap OK 7 To save the settings run the Backup utility See page 2 11 Using Windows CE Explorer you can now access anything on your local network for which you have permission GFK 2507 Chapter 4 Detailed Operation 4 31 To access a remote resource on a Windows network 1 Start E Windows Explorer The Explorer window appears File Edit View Go Favorites e alle laderess my Computer e D gt z Application Flash ely Network Program Files lata
5. International Americas Direct Dial 1 434 978 5100 Technical Support Email mailto support gefanuc com Customer Care Email mailto customer care gefanuc com Primary language of support English Europe the Middle East and Africa Online Technical Support http support gefanuc com Phone 800 1 GE FANUC 800 1 433 2682 Technical Support Email mailto support emea gefanuc com Customer Care Email mailto customercare emea gefanuc com Primary languages of support English French German Italian Czech Asia Pacific Online Technical Support http support gefanuc com Phone 86 400 820 8208 86 21 3217 4826 India Indonesia and Pakistan Technical Support Email mailto support cn gefanuc com China mailto support jo gefanuc com Japan mailto support in gefanuc com remaining Asia customers Customer Care Email mailto customercare apo gefanuc com GFK 2507 Chapter 1 Welcome 1 5 Firmware Updates Updates to the QuickPanel firmware will be made available through the Support web site http support gefanuc com This will allow updating the unit to the most recent released version of the firmware with the latest feature updates and defects addressed 1 6 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Chapter 2 Overview This chapter provides introductory information on the 8 QuickPanel View Control hardware and software with procedures for completing some
6. The backlit 8 4 inch diagonal panel employs TFT technology to provide a bright operator interface The display supports a resolution of 800 by 600 pixels A backlight timer is featured on all models You can extend the backlight life by turning off the backlight automatically 600 pixels 800 pixels 4 2 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 To adjust the display brightness 1 Inthe Control Panel double tap Display and choose the Brightness tab The Brightness dialog box appears Display Properties Background Appearance Backlight Brightness Brightness Fo Lowest Highest Mote Run Backup after changing the settings in order for the changes to be saved 2 Drag the Brightness slider between Lowest and Highest 3 Tap OK to exit the control panel 4 To save the settings run the Backup utility See page 2 11 GFK 2507 Chapter 4 Detailed Operation 4 3 To select backlight auto turn off 1 Inthe Control Panel double tap Display and choose the Backlight tab The Backlight dialog box appears Display Properties OK Background Appearance Backlight Brightness To save backlight lite you can adjust when the backlight automatically shuts off ve Auto turn off backlight after 60 minutes of continuous idle time 2 Select Auto turn off backlight while on external power 3 Tap OK to exit the control pane
7. programs Move slider to the right for more storage room Only unused RAM can be adjusted STU A E O O OO Program Storage Memory Allocated 5504KB Allocated 43824KB In Use l2KB In Use 61 2KB 2 On the Memory tab drag the slider to divide the DRAM into Storage and Program memory The amount of memory allocated to and used by each area is shown on the dialog box The amount of memory allocated to and used by each area is displayed numerically The blue bar indicates the current amount of unallocated DRAM and determines the boundaries within which the slider can move 3 Tap OK to apply the new setting 4 To save the settings run the Backup utility See page 2 11 Boot Loader ROM The Boot Loader ROM provides 512 KB of non volatile storage for the QuickPanel View Control s initialization program This program configures the QuickPanel View Control hardware then starts the operating system s execution This memory is not accessible from Windows CE Explorer nor should any attempts be made to modify the contents of this ROM GFK 2507 Chapter 4 Detailed Operation 4 4 Memory Expansion Slot The QuickPanel View Control is equipped with a 100 pin DIMM memory expansion slot which lets you increase DRAM to a total of 128 MB Memory Expansion Slot Disconnect power from your DC power supply before opening the QuickPanel View Control Working on a live unit may result in damage to equipment and injury to p
8. 9 Keyboard The QuickPanel View Control can be configured to use either or both a hardware keyboard and a software emulation keyboard as operator data input devices Typically an external hardware keyboard is used when in a development mode while the included Soft Input Panel is more applicable in an operational environment External Keyboard optional Any USB keyboard compatible with the QuickPanel View Control can be used as an input device for the unit The USB driver for the keyboard is included with the operating system and no setup is required To use an external keyboard simply plug and play A list of compatible devices keyboards USB mice compact flash cards etc may be found by visiting the GE Fanuc Support page accessible from http support gefanuc com Soft Input Panel The Soft Input Panel SIP is a touch screen version of a standard keyboard which can be used in place of a standard hardware keyboard An icon in the system tray lets you view or hide the SIP Soft Input Panel icon es 1 02 Pla To show hide the Soft Input Panel On the system tray of the task bar double tap the icon The Soft Input Panel appears disappears Note When the SIP is visible it can be dragged around the screen by its title bar to reveal different parts of the screen that would be obstructed from view by the SIP 4 10 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2
9. A 3 Microsoft File Viewers 2 15 O Operating system 2 6 p Panel cutout 3 3 Physical unit diagnostics B 2 Pocket Internet Explorer 2 8 diagnostics B 1 Power management 4 44 Power requirements A 1 Power supply connecting 3 2 Power up diagnostics B 1 Proxy server configuring 2 10 R Reboot 2 14 Remote resource accessing 4 32 Runtime setup 1 3 Shutdown 1 4 SNTP setting 4 49 Software 2 6 Specifications A 1 SRAM memory 4 39 Startup behavior configuring 4 37 Storage Manager 2 12 System Information 2 13 7 Technical support 1 5 Touch response diagnostics B 2 Touch Screen Display operation 4 2 Troubleshooting B 1 U USB port operation 4 26 Utility settings changing 2 19 W Windows network access 4 30 Index 2 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507
10. The Security Warning message appears This message informs you Windows will automatically trust any certificate issued by this Certification Authority 6 Click Yes to allow Windows to trust any certificate issued by this Certification Authority GFK 2507 Chapter 2 Overview 2 27 Chapter 3 Installation Procedures for Conformance and Compliance This chapter provides the following procedures for installing the QuickPanel View Control unit Connecting a DC Power Supply 3 2 Panel Cutout 3 3 Mounting Bracket Locations 3 4 Mounting the QuickPanel View Control in a Panel 3 5 Considerations for Choosing a Mounting Location For compliance to UL50 Type 4x rating the unit must be mounted to a flat surface of a Type 4X enclosure For compliance to NEMA 4 and 4x qualification the unit must be mounted in a comparably NEMA rated IP66 equivalent panel or enclosure For compliance to ATEX Directive and Class Zone 2 hazardous locations the unit must be mounted in an IP66 enclosure For adequate ventilation allow at least 3 inches of space between adjacent equipment and all sides of the QuickPanel Ensure that specified conditions of temperature and humidity are not exceeded In outdoor applications direct sun exposure may impose increased thermal loads on the QuickPanel leading to excessive temperature increases Cabinet design and orientation must be carefully considered to avoid exceeding the operational temperature limit
11. copy to be created if the runtimes are also writing to files in the project folders The utility can detect this situation and will warn you to stop the runtimes before making the backup You will not be able to create a backup while the runtimes are writing files GFK 2507 Chapter 2 Overview 2 17 To update a Machine Edition project You can update a Machine Edition application currently stored on the QuickPanel View Control with a revision stored on a flash device such as a CF card or USB memory stick 1 Insert the flash device containing an upgraded version of the Machine Edition project into the appropriate port 2 Reboot the machine see page 2 14 See the settings section below as depending on options set the update may or may not be enabled or may automatically update If there is more than one flash device with a valid project copy present a Select Media confirmation dialog will appear allowing you to choose which flash device to update with Select the device from the list and select OK to continue When a valid project is found on the flash device you will be prompted to install the project or skip it Tap OK to install or Cancel to skip the install and continue to boot If an invalid project is found an error message appears in a dialog box This dialog box must be closed before boot will continue 3 Remove the flash device from the port 2 18 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TF
12. expansion card Do not allow conductive material liquid or solid to contact the electronics of the QuickPanel GFK 2507 Chapter 4 Detailed Operation 4 33 Expansion Bus Connectors Note To ensure compliance to CE Mark the mounting screws must be used when installing an expansion card 4 34 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 DIP Switches The QuickPanel View Control is equipped with four DIP switches that control separate functions DIP switches are set to OFF by default in the factory DIP switch 2 is the Force Startup switch Turning this switch on forces the startup applications to run when the operating system is started DIP Switches On 1 2 3 4 Off GFK 2507 Chapter 4 Detailed Operation 4 35 When the switch is set to OFF the QuickPanel View Control operates normally displaying the startup splash screen You can skip running the startup applications by tapping the Don t run StartUp Programs button on the startup splash screen QuickPanel Control Os Version Windows CE MET 5 00 Platform QuickPanel Control 2 00 Build 33 Loaded Restoring Files Please wait When the switch is set to ON the startup programs are forced to run and the Don t run Startup Programs button is not available on the startup splash screen Note Do not adjust switches other than switch 2 They are reserved for fa
13. lt gt oala pph Prie Upper Case To reset the SIP Location If you accidentally drop the SIP off screen and can t drag it back on screen complete the following steps to reset the SIP to the center of the screen 1 In the Control Panel double tap Input Panel The Input Panel Properties dialog box shown on page 4 11 appears 2 Click Reset SIP location External Mouse optional Any USB mouse compatible with the QuickPanel View Control can be used as an input device for the unit The USB driver for the mouse is included with the operating system and no setup Is required To use an external mouse simply plug it into the appropriate port A list of mice and other devices that have been tested and are compatible can be found by visiting http support gefanuc com In the Technical Resources Browse by Product section of the page choose the Operator Interface Product Category and the QuickPanel View Product Name 4 12 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Communication Ports The QuickPanel View Control has two serial data communication ports COM1 and COM2 COM1 Serial The COM1 port is a general purpose bidirectional serial data channel that supports the EIA232C and ElA485 electrical standards The COM1 port can be accessed and configured as a direct or dial up remote networking connection as the port used by a terminal session mode
14. modem choose Dial Up Connection If you have a device select Direct Connection 5 Tap Next The Modem or Device dialog box appears depending on the connection type GFK 2507 Chapter 4 Detailed Operation 4 17 yl My Connection Ts My Connection Select a modem Select a device Hayes Compatible on COM1 erial Cable on COME TCP IP Settings Security Settings TCP IP Settings Security Settings 6 From the list choose the device or modem you want to use If a serial CF card is inserted it is available in the device list You can configure your device or TCP IP Settings at this time if you wish 7 Tap Finish for direct connection Device dialog box or Next for dial up Modem dialog box If you are adding a dial up connection the following dialog box appears Phone Number Fl My Connection Country region code il Area code 425 Phone number Force long distance Force local 8 Type the destination Country region code Area code and Phone number in the appropriate boxes 9 Select or clear the Force Long Distance or Force Local check boxes 10 Tap Finish 4 18 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 To add a virtual private network or PPP over Ethernet 1 From the Start menu tap Lr Settings and then e Network and Dial up Connections The Connection window appears 2 Double tap Make New Connecti
15. notices which may be included in this document The license does not extend to any other product regardless of whether such product is included with this licensed product in a single article No license is granted or shall be implied for any other use Additional information may be obtained from MPEG LA L L C See http www mpegla com The FCC requires the following note to be published according to FCC guidelines This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any changes or modifications to the product or installation that are not expressly approved by GE Fanuc could void the user s authority to operate the equipment under FCC rules Industry Canada requires the following note to be published This Class A digital apparatus complies with Canadian ICES 003 The following statements are required to appear for Class Division Zone 2 Hazardous Loc
16. of the most common tasks you will encounter In this chapter QuickPanel View Control Hardware 2 2 Provides a layout diagram showing user accessible controls and indicators and a block diagram showing module functions QuickPanel View Control Software 2 6 Working with Windows CE working with Pocket Internet Explorer backing up registry or desktop changes rebooting the system using Storage Manager and System Information utilities using Microsoft file viewers copying projects to the Flash Card updating a Machine Edition project from the CF card emulating a Pocket PC and using the HTTP File Transfer Utility GFK 2507 2 1 QuickPanel View Control Hardware Layout Diagram In addition to the primary touch screen interface the 8 QuickPanel View Control supports a variety of communication ports including an expansion bus to allow great flexibility in application The back of the QuickPanel opens allowing access to the expansion bus connector memory expansion connector DIP switches and battery The following diagram shows the physical layout of the QuickPanel View Control and the locations of ports and connections Remove power from the QuickPanel View Control before opening the back Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing the interior of the unit Do not allow conductive material liquid or solid to
17. on the QuickPanel View QuickPanel Control except in the specific and limited circumstances noted in the Grounding section above GFK 2507 Chapter 4 Detailed Operation 4 15 COM2 Serial The COM2 port is a general purpose bidirectional serial data channel that supports the EIA232C electrical standards A DB9P male connector mounted on the bottom of the enclosure provides standard signals as described in the following table 1 n c 2 RX 3 TX 4 n c 5 SG Signal Ground 6 n c 7 RTS 8 CTS 9 n c Shielded cable is required for compliance with CE Mark and FCC requirements The cable shield should be connected to the metal connector shell Shield and signal ground pin 5 of the 9 pin serial connector should not be connected directly together 4 16 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Working with COM ports To add a new remote networking connection 1 From the 4 Start menu tap L Settings and then Network and Dial up Connections The Connection window appears 2 Double tap Make New Connection The Make New Connection window appears Make New Connection Type a name for the connection Select 8 Dial Up Connection ie 0 Direct Connection O Virtual Private Network PPTP3 C Virtual Private Network L2TP 0 PPP over Ethernet PPPOE Type a name for the new connection Choose a connection type If you are configuring a
18. than the threshold value away from the current time on the QuickPanel View Control then the time is not updated Setting the Threshold to 0 tells the utility to always accept the time from the server This setting would be useful in a case where the backup battery has died and the QuickPanel View Control was power cycled since the internal clock would have reset back to January 1 1980 12 00 am GFK 2507 Chapter 4 Detailed Operation 4 49 To set SNTP 1 Inthe Control Panel double tap ng Date Time The Date Time Properties dialog box appears Date Time Properties k OK Ez Date Time SNTP Enable SNTP Server s MyTimeServer com Refresh 1 00 00 00 DD HH MM 55 Retry bo afo clos fo DD HH MM SS Threshold b afo joo po DD HH MM SS Update Now Note Tap Apply after making changes in any box 2 To add or modify SNTP settings select the SNTP tab To enable SNTP ensure the Enable SNTP check box is selected Enter the time server name in the Server s field Set the Refresh Retry and Threshold parameters Tap Update Now to update SNTP settings immediately Tap OK to finish To save the settings run the Backup utility See page 2 11 oe oe a R 4 50 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Appendix A Specifications See page A 6 for a list of agency approvals for environmental service and safety Physical Enclosure dimensions Height 7 34
19. web server at HT TP MyServer 2 22 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 FTP Server The FTP Server included with the QuickPanel View Control supports both standard RFC 959 and Explicit FTPS i e FTP SSL Auth TLS TLS C RFC 4217 It does not support SFTP or implicit FTPS which uses different ports and is based on SSH rather than SSL Y 5 a p Certificates Date Time Dialing Display Input Panel Internet Options A 2 Y PE Power Project Regional Remove Secure FTP Connection Transfer SETTINGS Programs Server All configuration of the FTP server is accomplished with the Secure FTP Server control panel applet By default the server is not enabled Once enabled a background program will run waiting for clients to connect Up to ten connections are supported Sessions that are idle for five minutes are terminated by the server Secure FIP Server allow Anonymous Access _ Require Username and Password Username Password support Secure Connection MM Required Server po E Certificate Note To save the settings run ball Backup see page 2 11 GFK 2507 Chapter 2 Overview 2 23 The Server supports Non secure operation All information including username password and data is transmitted with no encryption and susceptible to packet sniffing and various FTP attacks This is the default Both secure and non se
20. 507 To display the Soft Input Panel icon in the system tray 1 Inthe Control Panel double tap Input Panel The Input Panel Properties dialog box appears Input Panel Properties Input Panel Current input method EkKevboard Options Allow applications to change the input panel state Show Input Panel in system tray Reset SIP location 2 Select the Allow applications to change the input panel state check box 3 Select or clear the Show Input Panel in system tray check box 4 Tap OK 5 To save the settings run the Backup utility See page 2 11 The Soft Input Panel provides a standard QWERTY key layout with numeric keys at the top row as illustrated in the following picture Input Panel Esq1 2 3 4 5 6 7 8leJo e ee amie oie ole O RANE Shit z x e v b n em 000 GFK 2507 Chapter 4 Detailed Operation 4 11 Upper case characters are accessed by pressing the SHIFT key once This is equivalent to holding down the SHIFT key on a conventional keyboard The SHIFT key is active while the next key is pressed then reverts back to its unselected state The CAP key does the same thing as SHIFT but does not revert to lower case after another key is pressed Pressing the CAP key causes the Soft Inout Panel to remain in upper case mode The CTRL and ALT keys behave the same as the SHIFT key Input Panel Esq 1 0 4 s 8 _ pel Tab jo w E R T wjU tfo P t y cap a s p Fia H y Kit EN Z xo lvis nm
21. 7 WordArt is not supported Hyperlinks are not supported Some types styles and groupings of AutoShapes will not appear Word forms for Text boxes are not supported Elements from the form may be visible but will not be available for input Copy Project to Flash Card RestorePCCard is a custom utility for transferring Proficy Machine Edition Projects between compatible QuickPanel View Control units via CF cards USB flash keys or PCMCIA flash if the unit is fitted with the optional PCMCIA interface expansion card Flash memory not included with PCMCIA expansion card Caution Ensure that the copy or update operation is complete i e no busy or wait cursor displays before disconnecting power To copy a Machine Edition project onto a flash device 1 Ensure there is a blank flash device in the in the appropriate port 2 Double tap the ma Copy Project to Flash Card icon on the desktop If there is more than one of the supported flash devices installed a Select Media confirmation dialog will appear allowing you to choose the destination location for the backup From the drop list choose the destination and then select OK to continue This dialog does not appear when there is only one flash device present 3 Tap Yes when the Copy Project Query confirmation dialog box appears The system copies the project onto the flash device Creating a project copy while the Machine Edition runtimes are active may cause an incomplete
22. AM for data storage ensuring your valuable data will never be lost even during a power failure The many features of the QuickPanel View Control make it an obvious choice for a world of applications Your smart choice will provide reliable operation for years to come GFK 2507 1 1 Getting Started Basic Setup Your QuickPanel View Control is shipped ready for use after a few configuration steps To power up all you need to do is connect a DC power supply via the supplied quick connect plug Depending on your application you may also want to connect and configure optional input devices communications ports and expansion adapters see chapter 3 Optional Ethernet Connection Optional Expansion 1 0 A ee E Power Supply Caution Electrical Shock Hazard To avoid personal injury or damage to equipment ensure that the DC supply is disconnected from power and that the leads are not energized before attaching them to the unit s power supply plug 1 2 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Runtime Setup To download a Proficy Machine Edition application to a QuickPanel View or QuickPanel Control unit you must set up a data link between it and your development workstation For more information see Ethernet in chapter 3 and Downloading a Machine Edition Project in the Machine Edition online help Startup When you first start up the QuickPanel View or Q
23. GE Fanuc Intelligent Platforms Operator Interface Products 8 QuickPanel M View and 8 QuickPanel Control Fully Loaded Color TFT IC754VBFO8CTD IC754VGFO8CTD IC754CBFO8CTD IC754CGFO8CTD IC754OBFO8CTD IC5008CACOQO000 Hardware User s Guide GFK 2507 September 2008 GFL 002 Warnings Cautions and Notes as Used in this Publication Warning notices are used in this publication to emphasize that hazardous voltages currents temperatures or other conditions that could cause personal injury exist in this equipment or may be associated with its use In situations where inattention could cause either personal injury or damage to equipment a Warning notice is used Caution notices are used where equipment might be damaged if care is not taken Note Notes merely call attention to information that is especially significant to understanding and operating the equipment This document is based on information available at the time of its publication While efforts have been made to be accurate the information contained herein does not purport to cover all details or variations in hardware or software nor to provide for every possible contingency in connection with installation operation or maintenance Features may be described herein which are not present in all hardware and software systems GE Fanuc assumes no obligation of notice to holders of this document with respect to changes subsequently made GE Fanuc makes no re
24. M area Files placed in this area are not persisted over a power cycle reboot and use memory from the Storage Memory allocation For this reason remote users are only able to read rename and delete files from the FTP root directory Programs running on the QuickPanel can access the Temp ftp like any other folder but remote users cannot fill up storage memory 2 24 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 All removable flash devices appear to remote FTP users as directories off the FTP root directory PC Flash card partitions appear as directories such as PCFlashStorage and USB Flash Keys as directories such as USBStorage The names contain no spaces as FTP commands do not support spaces in filenames Full access privileges are granted for the client in these folders devices Removable flash device directories are captured when a session is opened and are not changed while the session exists If you start without a CF card installed you will have to close your session and login again to see the CF directory If the CF card existed when you logged in and is removed and inserted it will still work provided the CF card s device name did not change during reinsertion A server certificate is a special type of document that contains information about the server s settings and a chain of electronic signatures to guarantee the document has not been altered A Server certificate must
25. Part of the DRAM 15 8 MB is reserved for the Windows CE operating system and is not accessible by user applications The other 48 6 MB is split between two functions an object store for temporary file storage and the main memory for running programs Typically compressed programs stored in FLASH are expanded and moved to DRAM for execution Temporary storage of program variables or data files is also provided by DRAM any data stored in DRAM will not be retained through a power cycle or reboot The split between program memory and storage memory may be adjusted as necessary to make more room for one or the other depending on your specific application needs For example if you find that an application is short of memory use the System Properties dialog box to alter DRAM memory allocation Setting Program Memory too low may prevent additional applications from starting or may cause currently running applications to fail due to lack of memory Setting Storage Memory too low may prevent the saving of files into the object store portion of the file system which may also cause application failures 4 40 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 To change the DRAM memory allocation 1 Inthe Control Panel double tap qa System The System Properties dialog box appears System Properties E OK Memory Device Name Copyrights Move slider to the lett for more memory to run
26. Storage Manager Use the buttons in the Storage Manager dialog box to format or scan the CF card B 2 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 A Agency Approvals A 6 Backup 2 11 Basic setup 1 2 Battery removing 4 46 specifications A 5 Battery backup 4 44 Battery Backup 4 44 Block diagram 2 5 Boot loader ROM 4 41 Calendar clock specifications A 5 CF card copying a project to 2 17 CF port operation 4 25 Clock operation 4 47 setting 4 47 Communication ports operation 4 13 specifications A 4 CPU specifications A 2 Cutout panel 3 3 D Diagnostics B 1 Dial up connection configuring 2 8 Dimensions bezel A 1 module A 1 panel cutout 3 3 GFK 2507 Index DIP Switches 4 35 Display operation 4 2 specifications A 2 DRAM adding 4 43 DRAM memory 4 40 E Emulate PPC 2 21 Environmental requirements A 5 Ethernet ports operation 4 27 Expansion bus 4 33 Expansion memory diagnostics B 2 Expansion ports specifications A 3 E Flash memory adding 4 39 operation 4 38 Front panel specifications A 2 FTP Server 2 23 G Getting started 1 2 H HTTP File Transfer Utility 2 21 IP address setting 4 28 Index 1 Index L LAN connection 2 9 Layout diagram 2 2 M Machine Edition project updating 2 18 Memory 4 38 specifications A 3 Memory expansion slot 4 42 specifications
27. System Information program 1 On the desktop double tap a System Information The System Information splash screen appears QuickPanel Control OS Version Windows CE MET 5 00 Platform GuickPanel Control 2 00 Build 33 Loaded 2 Tap More Info to open the Advanced System Information window or tap Close to continue Network information alone can be viewed by double tapping the LAN icon displayed on the taskbar for each connection GFK 2507 Chapter 2 Overview 2 13 Reboot Reboot performs a controlled and orderly shut down of the Windows CE operating system then restarts the QuickPanel View Control This ensures all open files are closed properly To reboot the system 1 To save changes to system configurations run Backup see page 2 11 2 Tap ey Start point to an Programs then the System folder and tap 2 Reboot A confirmation dialog box appears 3 Tap Yes The operating system reboots 2 14 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Microsoft File Viewers Included with Windows CE are applications that enable you to view files in three popular formats Microsoft Word Excel and Adobe PDF Each application provides online help for its use To access the Microsoft file viewers Tap Start point to an Programs point to Microsoft File Viewers and then choose one of the following Microsoft Excel Viewer pa Microsoft PDF Viewer Mi
28. T September 2008 GFK 2507 To change utility settings This utility can be configured to change the way the Machine Edition project update will occur 1 Tap ey Start point to gt Settings and then tap gt Control Panel 2 In the Control Panel double tap T Project Transfer to configure the RestorePCCard utility settings 3 Select from the list which option you wish to use Project Tr OK Project Restore Option Wait for Answer Wait for Answer This is the default setting If an update image is present the user will be prompted to install this update as described above If the update dialogs are not closed the unit will not complete the boot cycle Always Restore With this setting there will be no prompts to confirm installing the update if one is present The update will occur as though the user selected the option to install the update Note f more than one update is found due to multiple flash devices having valid update images the user will still have to select which image to use For fully automatic updates ensure there is only one update image present Skip at Startup With this setting all update images are ignored during the boot GFK 2507 Chapter 2 Overview 2 19 Timeout after With this setting selected a second setting control appears allowing for entry of a timeout interval in seconds for the update utility to wait for a user response to its dialogs before automatically continu
29. The QuickPanel View Control is equipped with a 10BaseT 100BaseTX auto negotiate full or half duplex Ethernet port IEEE802 3 You can connect an Ethernet network cable unshielded twisted pair UTP CAT 5 to the unit via the RJ45 connector on the bottom of the enclosure LED indicators on the port indicate channel status Access to the port is possible either by Windows CE network communications or by your custom application The following diagram shows the location orientation and pin out of the Ethernet port Bottom TX_D1 TX_D1 RX_D2 NC NC RX_D2 NC NC On Channel OK On Packet received Bi or transmitted 8 1 O0O N O OCI BA O N GFK 2507 Chapter 4 Detailed Operation 4 27 The QuickPanel View Control provides two methods for setting an IP address DHCP Dynamic Host Configuration Protocol This is the default method that is carried out automatically There must be a DHCP server on the connected network for a valid IP address to be assigned Contact your network administrator to ensure correct DHCP server configuration Manual method You uniquely specify the numeric addresses for the QuickPanel View Control the Subnet Mask and the Default Gateway if applicable Use a crossover cable to connect the QuickPanel View Control directly to a PC When connecting to a LAN HUB use a straight through cable Contact your network administrator for further information To set an IP address 1 From th
30. ations 1 WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1 DIV 2 2 WARNING EXPLOSION HAZARD WHEN IN HAZARDOUS LOCATIONS TURN OFF POWER BEFORE REPLACING OR WIRING MODULES 3 WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR AREA IS KNOWN TO BE NON HAZARDOUS Power input and output I O wiring must be in accordance with Class I Division 2 wiring methods Article 501 410 b of the National Electric Code NFPA 70 and in accordance with the authority having jurisdiction Users must supply an isolated DC supply to power the QuickPanel models covered by this manual The power input to the QuickPanel must be limited by a slow blow fuse not to exceed a maximum 100VA For less than 20Vdc input the fuse must be rated for no more than 5A For a complete list of agency approvals please refer to Appendix A GFK 2507 Contents WOICO Mii 1 1 Geno taned Seas sccncere So adosht sect a a bases 1 2 Fechiical SUD DON canilla odie 1 5 Elmware Updates iio 1 6 OVEIVIEW Aaa 2 1 QuickPanel View Control Hardwarre ccccsssccccccececeeeeeeeeessesessssseeeeaees 2 2 QuickPanel View Control Software cccccsssscceceeeceeeeeeeeeseessssessssesssaaees 2 6 Installation Procedures for Conformance and Compliance 3 1 Connecting a DC Power Supply oocccccnccccccccoonccnnnccnoncnonccnnnnnnnonanncnnnnnnnononans 3 2 Pan
31. be chosen from the certificates available in the QuickPanel View Control Secure FTP Server control panel applet re an a Certificates Date Time Dialing Display Input Panel Internet Options a Y 2 Y PL Power Project Regional Remove Secure FTP Connection Transfer Settings Programs Server The certificate itself is imported with the Certificates control panel applet The main requirements of the certificate are that it must have the server authentication key usage attribute set and the name of the certificate should match the name used to connect to the FTP server which could be the IP address of the server Certificates can either be purchased from an online vendor and imported into the QuickPanel View Control or a self signed certificate can be generated from the QuickPanel View Control The benefit of a purchased certificate is that any user that has the root certificate used by the online vendor can determine the GFK 2507 Chapter 2 Overview 2 25 certificate is valid without the need for any additional information A self signed certificate is only known to be valid by clients that have added the certificate to their trusted list Users can still access a server using a self signed certificate but they lose the ability to verify that no one is operating as an imposter somewhere on the network between them and the server To create a self signed certificate 1 Open a command prompt window by selecting the Start menu se
32. commended that you use a blunt stylus when calibrating the touch screen Press and hold stylus on the center of the target Repeat as the target moves around the screen 4 Follow the directions given to calibrate the touch screen GFK 2507 Chapter 4 Detailed Operation 4 7 5 Tap the screen to preserve the new setting or wait out the time limit to revert to previous settings Mew calibration settings have been measured Tap the screen to register saved data Wait to cancel and keep the current setting Time limit 8 sec 6 To save the settings run the Backup utility See page 2 11 4 8 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 To set the double tap sensitivity 1 Inthe Control Panel double tap E Stylus The Stylus Properties dialog box appears Stylus Properties Calibration Double tap this grid to set the double tap sensitivity for both the speed and physical distance between taps Double tap this icon to test your double tap settings If this icon doesn t change adjust your settings using the grid above Choose the Double Tap tab Double tap the grid to enter a setting 4 Double tap the test icon to check the setting If the test icon doesn t change when you double tap it double tap the grid again 5 Tap OK to finish 6 To save the settings run the Backup utility See page 2 11 GFK 2507 Chapter 4 Detailed Operation 4
33. contact the electronics of the QuickPanel The right LED is tricolor green red or amber and programmable The left LED is green when power is applied and red if either backlight fails Note Backlights are not field replaceable 2 2 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Rear View with Back Panel Open Memory Expansion Slot Battery Expansion Bus Connectors DIP Switches Power Connector GFK 2507 Chapter 2 Overview 2 3 Physical Layout of QuickPanel View Control Front Right Side CF Port Touchscreen LCD Display LEDs Bottom USB Ports oe A RS232 485 Port COM1 Ethernet Port RS232 Port COM2 2 4 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Block Diagram The 8 QuickPanel View Control is based on the Marvell XScale PXA255 microprocessor and employs large scale integration to provide high performance with a small footprint The following block diagram illustrates the major functional areas of the QuickPanel View Control and the interfaces between them 64 MB DRAM DRAM Expansion 100 pin DIMM 64 MB max 64 MB Flash 512 KB EPROM Boot 512 KB BBSRAM Batt Monitor Field Bus Expansion Proprietary Expansion GFK 2507 Data Address Bus Touch Screen 100Mhz Bus 4 pos DIP Switch Real time Clock Status LEDs 2
34. crosoft Word Viewer File Viewer Limitations Microsoft Excel Hyperlinks are not supported Data Tables in charts are not supported WordArt is not supported Plain text will be substituted Surface charts An image representing an unsupported chart will appear in the chart s location Certain types of 3D charts will be mapped to equivalent 2D charts Supported 3D charts are only shown at a fixed camera angle Vertical text in the worksheet is mapped to 90 degree rotated text GFK 2507 Chapter 2 Overview 2 15 Microsoft PDF Advanced features such as PDF forms encrypted files CCITTFaxDecode images clip paths predictive GZIP decoding CMYK JPEGs annotations and transitions are not supported In addition the Microsoft PDF Viewer operates with the following limitations Poly polygons are treated as polygons and therefore may have the interiors filled Embedded TrueType fonts are not used They are mapped to existing fonts already installed on the system Colors from unsupported color spaces such as ICCBased or DeviceN color may be displayed incorrectly Text rotation is only shown in 90 degree increments Type 1 fonts are mapped using either the encoding or Unicode mappings if possible Type 3 fonts are not supported but an attempt is made to map them if a Unicode map exists Microsoft Word 2 16 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 250
35. ctory functions Also note that the Off position of the switches is toward the DIMM connector On toward the COM1 connector 4 36 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 To configure startup behavior Disconnect power from your DC power supply before opening the QuickPanel View Control Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing the interior of the unit Do not allow conductive material either liquid or solid to contact the electronics of the QuickPanel 1 Open the back cover of the QuickPanel View Control 2 Locate the DIP switches and set DIP switch 2 to ON The startup applications are now forced Note Do not adjust the other switches They are reserved for factory functions GFK 2507 Chapter 4 Detailed Operation 4 37 Memory The QuickPanel View Control supports a variety of memory subsystems to ensure the requirements of your application are met All system memory is tied directly to the microprocessor s address and data busses for fastest access To increase DRAM by up to 64 MB a 100 pin DIMM memory expansion slot is also included Flash Memory This 64 MB block of non volatile memory is the main long term program storage for the QuickPanel View Control operating like a virtual hard drive from the point of view of Windo
36. cure operation This mode of operation either secure or non secure is determined by the client when it connects This operation is active when Support Secure Connection is enabled but Required is not Secure operation only Secure operation uses encrypted connections for the control connection The data connections are encrypted or non encrypted based on the settings of the client Secure operations also require the server to have a signed server certificate it can use to prove it is the actual machine the client wanted to reach and not an imposter This mode is active when both Support Secure Connection and Required are enabled By default the server requires a username password combination to be configured The server supports one username password combination to authenticate remote users There are three modes of authentication operation No support for anonymous login This is the default Anonymous with no password This is enabled when Allow Anonymous Access is checked but Require Username and Password is not checked Anonymous with password requested but not validated This is enabled when Allow Anonymous Access and Require Username and Password are checked This can prevent some types of attacks and is required by some clients Once connected a remote user is logged into the FTP root directory This is available from the QuickPanel View Control as Temp ftp and is a volatile RA
37. d herein The entire risk as to the quality and performance of such information equipment and software is upon the buyer or user GE Fanuc shall not be liable for any damages including special or consequential damages arising out of the use of such information equipment and software even if GE Fanuc has been advised in advance of the possibility of such damages The use of the information contained in the manual and the software described herein is subject to GE Fanuc s standard license agreement which must be executed by the buyer or user before the use of such information equipment or software Notices GE Fanuc reserves the right to make improvements to the products described in this publication at any time and without notice 2008 GE Fanuc Intelligent Platforms All rights reserved QuickPanel View and QuickPanel Control are trademarks of GE Fanuc Intelligent Platforms in the United States and other countries Any other trademarks referenced herein are the property of their respective owners and used solely for purposes of identifying compatibility with the products of GE Fanuc The 8 QuickPanel View Control has been tested and found to meet or exceed the requirements of U S 47 CFR 15 Canadian ICES 003 Australian AS NZS 3548 and European EN55022 regulations for Class A digital devices when installed in accordance with guidelines noted in this manual Microsoft requires the following notes be published according to thei
38. e 4 46 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Real time Clock The QuickPanel View Control has a programmable real time clock capable of reporting the current time in Year Month Day Hour Minute Second The time is set from the Windows CE interface and retained through a power cycle if battery backup is available Daylight saving time is enabled by a check box within the dialog box The time can be displayed in the system tray on the task bar To set the real time clock 1 Inthe Control Panel double tap ad Date Time The Date Time Properties dialog box appears Date Time Properties kd OK Date Time stp E March 2008 Current Time MTWTEF 9 25 45 AM 25 26 27 26 29 l 10 11 12 13 14 17 18 19 20 21 24 PE 26 27 28 eae 31 1 2 3 4 5 Time Zone GMT 07 00 Mountain Time US amp Canad gt Note Tap Apply after making changes in any box 2 To modify the date select the Date Time tab 3 Tap the year to choose a new year tap the month to choose a new month 4 Tap a date to specify the day of month From the Time Zone box choose your zone GFK 2507 Chapter 4 Detailed Operation 4 47 6 Select Auto Adjust DST to configure the clock to automatically compensate for daylight savings time 7 Inthe Current Time box adjust the hours minutes and seconds Tap OK to finish 9 To save the settings run the Backup utility See page 2 11 To di
39. e Control Panel tap Network and Dial up Connections The Connection window appears File Edit View Advanced ipt 3 A ME nl A Make New LAN1 Connection a 2 Select a TL connection and choose Properties The Built in Ethernet Port Settings dialog box appears 4 28 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Built In 10 100 Ethernet OK IP Address Warne Servers An IF address can be automatically assigned to this computer Specify an IP address IP Address LTT EA Subnet Mask EJ TI Default Gateway EJ TI 3 Select a method Obtain an IP address via DHCP automatic Specify an IP address manual 4 Enter the IP Address Subnet Mask and Default Gateway numbers obtained from your network administrator manual method only 5 Tap OK To save the settings run the Backup utility See page 2 11 If the DHCP method was selected the network server will assign an IP address while the QuickPanel View Control is initializing You must be connected to the network After setting an IP address for the QuickPanel View Control you can access any network drives or shared resources for which you have permission GFK 2507 Chapter 4 Detailed Operation 4 29 To set up access to a Windows network 4 1 Inthe Control Panel double tap System The System Properties dialog box appears System Properties
40. e the system completes writing to flash and closes all files see Shutdown in chapter 1 To add Flash memory with a CF Card Inserta Compact Flash card into CF Port see page 4 25 The unit immediately reads the new secondary storage If the disk requires formatting you will be prompted to do so New memory appears in Windows CE Explorer as PCFlash Storage External flash memory devices are named after their types of connection and order of attachment For example if you connect two flash memory devices one via the CF port and one via the FieldBus connector the first device connected is named PCFlash Storage the second PCFlash Storage2 At powerup a CF port device is recognized and named first Otherwise name depends on connection order SRAM Memory This 512 KB block of static RAM is battery backed to provide data retention through a power cycle This memory block is shared by the operating system and user applications A portion of the SRAM memory operates as a virtual hard drive and is accessible from the Windows CE Explorer It is represented as the SRAM Storage folder A typical application program would create a file in this folder and store critical program data in that file The portions of SRAM used by the operating system and by user applications varies between models GFK 2507 Chapter 4 Detailed Operation 4 39 DRAM Memory The QuickPanel View Control is equipped with 64 MB of dynamic RAM
41. el CUTOUT ss A Gaia 3 3 Mounting Bracket Local Suicide 3 4 Mounting the QuickPanel View Control in a Panel ooonnccccucococccccnnnnnnncononos 3 5 Detailed OPONE ia aaa edad 4 1 TOUCH Screen DIS il 4 2 COMMUNICATION F OMS uns edad 4 13 CERRO eeraa 4 25 Universal Serial Bus USBluasina iiaeia a a ai 4 26 EREM E Earn naea E A AA 4 27 EXDANSION BUS avena eiA 4 33 DIP OWICIES adn e a i cate ete asec reece eS 4 35 MEMO Var n 4 38 Other SUDSY Stemi e ei tae sse adele 4 44 SDECINIGAHONS ii a ieee es A 1 MY SIG AN nadia A 1 DEPO WERE Deyn tei sien ee sa tetova A 1 LIS DI AY a a a nutes acm aiencatu mates A 2 Front FRANG keia a A 2 A A A 2 AA e A A ERR A 2 o A E E A 3 iii Contents Memory EXpansion lO inca dla A 3 EXPANSION ONS arrolla to cono A 3 Communication PONS uscar id A 4 ENVIFOAMENTa uvas tonada ibarra A 5 O A 5 Candar GlOck sica A Ae ieee tees A 5 AJENO APDO VA Saad A 6 DIAQHOSUGCS sorene A A A A A A A B 1 POW SI UD salad B 1 Pocket Internet EXPO eta aa aa aia B 1 PAYSEC ANIN raaa E astute B 2 IV 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Chapter l Welcome Congratulations on your purchase of a QuickPanel View Control The QuickPanel View Control is available in different configurations to suit your requirements either as a full featured HMI or as a combination of HMI and controller for local and distributed control applications Equally adept in a n
42. ers Accessing the Compact Flash CF card causes the system to run slowly or hang up Suggested remedy Ensure that configured I O or communications channels such as serial or Ethernet are operating without error These errors can cause higher system overhead leading to delayed response to touch inputs Ensure that flash drives internal or external are operating without error If the flash drives are highly fragmented or corrupted reads and writes to the drive can experience significant delays leading to delayed response to touch inputs Corrupted external flash drives may be corrected with Storage Manager See Storage Manager in chapter 3 When the system is first started observe the screen to notice any memory error messages from the boot loader If any messages appear such as DIMM not 12 row DIMM not 32 bit DIMM refresh unsupported power down the system and remove the memory module If the error message is displayed from the Windows CE desktop also power down the system and remove the memory module For proper operation expansion memory modules must meet the requirements stated in Appendix A Specifications Touch screen may need recalibration Select Start then Settings Control Panel Stylus and then the Calibration tab Follow the on screen directions The CF card may be corrupted or full Delete some files or reformat the CF card Select Start then Settings Control Panel and then
43. ersonnel Always use anti static precautions when accessing the interior of the QuickPanel View Control Do Not Allow conductive material liquid or solid to contact the electronics of the QuickPanel 4 42 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 To install additional DRAM 1 Disconnect power from the DC supply 2 Open the rear access cover 3 Insert the new DIMM carefully into the expansion slot noting the orientation of the pin locators When the DIMM is fully seated lift each side clip until it clicks into place GFK 2507 Chapter 4 Detailed Operation 4 43 Other Subsystems Power Management The QuickPanel View Control s Power Properties control panel displays the status of the backup battery The Battery Very Low Or Missing En icon appears in the taskbar when the battery is either missing or very low To access the Power Properties control panel 1 Inthe Control Panel double tap ge Power The Power Properties dialog box appears Battery Backup Batteries Good Lowy Very Low Battery Backup Auxiliary backup power for the real time clock and SRAM is provided by a non rechargeable internal lithium battery 3VDC BR2032 ensuring that no loss of data occurs when the main DC supply is removed Backup power is enabled or disabled by installing or removing the battery accessed via the rear panel as shown in the following illustration 4 44 8
44. etworked environment or as a standalone unit the QuickPanel View Control is the ideal solution for factory floor HMI and control Powered by Microsoft Windows CE today s embedded control operating system of choice the QuickPanel View Control provides a fast track for application program development The commonality with other versions of Windows simplifies porting your existing program code Another benefit of Windows CE is the familiarity of the user interface shortening the learning curve for operators and developers alike The availability of third party application software makes this operating system even more attractive The 8 QuickPanel View amp QuickPanel Control is an all in one microcomputer designed for maximum flexibility The design based on an advanced Marvell microprocessor brings together a high resolution touch screen operator interface with a variety of I O options With many standard ports and expansion busses from which to choose you can connect to most industrial equipment The QuickPanel View Control is equipped with several memory types to satisfy even the most demanding applications A 64 MB section of DRAM is split between the operating system an object store and application memory Functioning as a virtual hard drive a 64 MB section of non volatile FLASH memory is divided between the operating system and persistent storage for application programs The retentive memory consists of 512 KB of battery backed SR
45. i Storage Documents gt p SRAM Temp Window s Control Storage Panel lnk 2 Type in the Address box or choose from a list the path to a remote resource For example MyRemoteComputer MyFolder specifies the folder named MyFolder on a computer with the name MyRemoteComputer 3 Press ENTER The resource specified is displayed as a collection of files and folders It can take a few momenis to retrieve the data from your local network Note You can use the NET command from the shell to map a network resource to the QuickPanel View Control for frequent access The resource then appears in the Network folder 4 32 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Expansion Bus An expansion bus is included with the QuickPanel View Control and optional modules that mount directly to it are available For more information on expansion modules contact your distributor The expansion bus connectors are accessed by opening the back of the unit Disconnect power from your DC power supply before opening the QuickPanel View Control Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing the interior of the unit Ensure all pins are properly aligned when inserting expansion cards Misalignment could cause damage to the QuickPanel View Control and or the
46. ify the maximum number of nodes or devices that can be connected to a TIA EIA 422 or 485 network Instead the standards limit the number of electrical connections by specifying that a maximum of 32 unit loads may be connected The QuickPanel View or QuickPanel Control presents one unit load Interconnect Always use twisted pair cabling and group complimentary signals into media conducior pairs TXA with TXB for example Use a cable with a characteristic impedance of 100 ohms to 120 ohms A wire gauge of 24 AWG is commonly used Maximum cable length is 4 000 1 219 2m but may be less due to cable impedance connection quality data rates and other factors Termination Always provide proper termination at each end of the 422 485 network The QuickPanel View provides built in termination resistance when pin 9 TRMRXB is connected to pin 10 RXA Caution Do not terminate every node Only terminate the end nodes 4 14 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 A signal return path between transmitting and receiving devices must be provided This return path is separate from the Rx and Tx data lines and the other 422 485 signals supported by the QuickPanel View QuickPanel Control and may be provided by a separate conductor in the cable Connect both ends of the signal return conductor to Signal Ground pin 7 Shielding or use of a twisted pair for this connection is not
47. in 186 4 mm actual see Getting Started Width 8 97 in 227 8 mm in chapter 1 for cutout dimensions Depth 3 03 in 76 9 mm Bezel dimensions Height 8 18 in 207 7 mm Width 9 80 in 248 9 mm Depth 0 35 in 9 mm 4b 1819 DC Power Input Voltage 10 8 to 30 0 VDC Power Supply Conductor Size 12 to 18 AWG For compliance to CE Mark the isolated frame ground must be connected Recommended frame ground connection is via the shortest possible route using 14 AWG Connector Vendor p n Phoenix Contact 1834916 Note The torque range for the attaching screws is 4 to 6 inch lbs GFK 2507 A 1 Size 8 4 21 3 cm diagonal Colors 65 536 Resolution 800 x 600 pixels Fabrication Backlight Cold Cathode Fluorescent CCFL rated half life 50 000 hours Note Backlight is not field replaceable Luminance 400 NITS Front Panel Bezel Material Valox 3706 For material specifications visit www gepolymerland com Membrane Material Touch screen top layer PET polyester with an acrylic hard coat Power status indicator green with power applied red if either backlight fails Programmable tri color green red amber Touch Screen Resistive 12 bit Resolution after calibration X axis 800 cells Y axis 600 cells CPU Clock speed 400 MHz A 2 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Memory SRAM 512 KB P
48. ing to boot without an update occurring The user has the amount of time specified to either cancel the update or continue with the update as normal Setting the time to O seconds will make this option operate the same as the Skip at Startup setting Project Restore Option Timeout after y T seconds 4 Select OK to keep your setting choice 5 To save the settings run Backup see page 2 11 2 20 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Emulate PPC Emulate PPC is a utility that allows the QuickPanel to emulate a Pocket PC 2003 during an ActiveSync session enabling the download of third party Pocket PC 2003 software To use Emulate PPC during an ActiveSync session 1 Start Y Windows Explorer double tap Windows then double tap EmulPPC The Emulate PPC dialog box appears 2 Start the ActiveSync session When installation of third party software is complete close the dialog box to deactivate Emulate PPC HTTP File Transfer Utility The HTTP File Transfer Utility HF TU is a small standalone command line program that allows you to send and delete files to and from computers over a network The HFTU uses the HTTP protocol so you can even send files to computers over the Internet Run the HTTP utility from a command line prompt from a batch file BAT or as an application call in a script The HTTP utility is an executable EXE file inc
49. ions for remaining within the stated limits must be considered where additional external thermal loads are imposed on the QuickPanel These could include large heat producing motor drives or power supplies in the same cabinet or in outdoor applications involving direct sun exposure Battery Panasonic BR2032 3V 190mAh lithium Approximate Calendar Clock GFK 2507 Appendix A Specifications A 5 Agency Approvals Model number ES0822 Quickpanel Control View Station is intended for industrial environments and when properly installed shall comply with the following agency approvals Description Agency Standard Comments or Marking North American Safety for UL 1604 C UL Certification by Underwriter s Hazardous Locations Class Laboratories to UL standard and Div 2 Groups A B C D equivalent CSA standard Enclosures for Electrical UL 50 Certification by Underwriter s Equipment Laboratories to Type 4 4X Explosive Atmospheres ATEX when Certification in accordance with Directive European Safety for mounted in an IP66 European directives refer to Hazardous Locations enclosure Declaration of Conformity Equipment Group II Category 3 Low Voltage Directive Certification in accordance with European Safety for Industrial European directives refer to Control Equipment Declaration of Conformity Electromagnetic Compatibility Certification in accordance with Directive European EMC for European directives refer to Indus
50. ird party sources Pocket Internet Explorer does not support VBScript however VBScript components are included in the operating system and may be used by third party applications such as Proficy Machine Edition A connection can be established over a dial up connection default or an Ethernet network The Ethernet or dial up connection must first be properly configured To configure a dial up connection 1 Start S Pocket Internet Explorer 2 From the Tools menu choose Options The Internet Options dialog box appears Internet Options Use LAN Autodial name Network Access the Internet using a proxy server Address Port fo Bypass proxy server for local addresses 3 On the Connection tab select the dial up connection from the Autodial name box This example uses a connection named MylSP 4 Tap OK 5 To save the settings run ball Backup see page 2 11 2 8 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 To configure a LAN Connection 1 Start 6 Pocket Internet Explorer 2 From the Tools menu choose Options The Internet Options dialog box appears Internet Options General Connection Privacy Advanced 7 Use LAN Autodial name MySp 7 Network Mm Access the Internet using a proxy server Address Port feo B Bypass proxy server for local addresses 3 Onthe Connection tab select the Use LAN check box 4 Tap OK
51. it the number of times you remove and reinstall the unit Too many installations may cause gasket set and degradation of the seal GFK 2507 Chapter 3 Installation Procedures for Conformance and Compliance 3 5 Chapter 4 Detailed Operation Touch Screen Display 4 2 Adjusting the display brightness configuring backlight auto turn off calibrating the touch screen and setting the double tap sensitivity Keyboard 4 10 Using an optional external keyboard and displaying the Soft Input Panel Communication Ports 4 13 Description and pin assignments for the COM1 and COM2 serial ports cabling and working with serial COM ports CF Port 4 25 Using the compact flash CF port Universal Serial Bus USB 4 26 Using the USB port Ethernet 4 27 Setting an IP address Setting up access to a Windows network Accessing a remote resource on a Windows network Expansion Bus 4 33 Using the expansion bus to connect optional modules DIP Switches 4 35 Configuring startup behavior Memory 4 38 Adding Flash memory with a CF Card changing the DRAM memory allocation installing additional DRAM Other Subsystems 4 44 Accessing the Power Properties control panel removing and replacing the internal battery setting the real time clock and displaying the time on the taskbar GFK 2507 4 1 Touch Screen Display The QuickPanel View Control has an integrated flat panel display providing 16 bits per pixel for a total of 65 536 colors
52. l 4 To save the settings run the Backup utility See page 2 11 4 4 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Touch Screen The QuickPanel View Control display is coupled to a resistive touch panel with 12bit resolution When the QuickPanel View Control is properly calibrated this translates into a grid of touch cells on the face of the display A blunt stylus should always be used during calibration for greatest accuracy During normal operation use of a finger or a soft and pliable blunt object is recommended to preserve the maximum reliability of the touch screen 600 pixels 800 pixels GFK 2507 Chapter 4 Detailed Operation 4 5 To calibrate the touch screen 1 Inthe Control Panel double tap E Stylus The Stylus Properties dialog box appears Stylus Properties Double Tap Calibration E If your Windows CE device is not responding properly to your taps You may need to recalibrate your screen Recalibration involves tapping the center of a target If you miss the center keep the stylus on the screen slide it over the target s center and then litt the stylus To start tap Recalibrate 2 Choose the Calibration tab 4 6 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 3 Tap the Recalibrate button A cross hair target is displayed Note For greatest accuracy it is re
53. lecting Programs then Command Prompt 2 From the command prompt type genslfcert CN lt unique identifier gt You may specify a unique identifier of your choice such as machine name machine location or IP address in place of unique identifier 3 A self signed certificate is created in the My Certificates section of the certificates Control Panel This will create a self signed certificate in the My Certificates section of the certificates control panel and a SelfSigned cer file in My Computer which can be transferred to FTP Clients as a trusted source Certificates may be managed through snap ins to the Microsoft Management Console or other third party management consoles A Backup should be performed after configuring the FTP server and or creating the self signed certificate 2 26 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 To install a certificate on an FTP Client 1 Double click the certificate Select the General tab The Certificate properties are displayed 2 Click the Install Certificate button The Certificate Import Wizard appears 3 Click Next to continue The Certificate Store screen appears 4 Specify whether Windows should place the certificate in a certificate store or select another location Click Next to continue The Completing the Certificate Import Wizard screen appears 5 Click Finish to complete the installation of the certificate
54. luded in the 8 QuickPanel View amp QuickPanel Control s operating system The HTTP utility currently supports two file transfer commands COPY and DELETE Note In order to function the HTTP File Transfer utility requires both computers to have web servers that support PUT functionality Most web servers support PUT including the Proficy Machine Edition web server installed with the runtimes for View and Logic Developer PC If in doubt check the documentation for your web server GFK 2507 Chapter 2 Overview 2 21 To use the HTTP utility 1 From the Start menu choose Programs then choose Command Prompt The Command Line editor appears File Edit Help Pocket CMD vy 4 10 4 2 Type commands as required 3 Use the following syntax HTTPUTIL COPY source destination Where source is the URL of the source file and destination is the URL of the destination file For example HTTPUTIL COPY MyFile txt http MyServer webfiles MyFileBACKUP txt Copies a file called MyFile txt on drive C of the local computer to the webfiles folder under the web server at MyServer Note that you can rename a file as you copy it HTTPUTIL DELETE url Where url is the remote URL of the file you want to delete This URL must use the or HT TP syntax For example HTTPUTIL DELETE http MyServer webfiles MyFileBACKUP txt Deletes a file called MyFileBACKUP txt from the webfiles directory under the
55. m link only from a user created application utility A connection can be configured to reside on a network supporting a TCP IP protocol A DB25S female connector mounted on the bottom of the enclosure provides standard signals as described in the following table 1GND Frame Ground 14 VCC 5VDC 0 5A 2 TX EIA232C 15 TXB ElA485 3 RX EIA232C 16 RXB ElA485 98 ARTS ElA2320 17 n c 50 5 CTS ElA232C 18 CSB ElA485 EE 6 DSR ElA232C 19 ERB ElA485 So 7 SG Signal Ground 20 DTR ElA232C So 8 DCD EIA232C 21 CSA ElA485 o9 9 TRMRXB ElA485 22 ERA EIA485 en 10 RXA ElA485 23 n c 11 TXA ElA485 24 n c 12 n c 25 n c 13 n c Note Pin 14 is fused with a field replaceable 1 0A fast blow fuse GFK 2507 Chapter 4 Detailed Operation 4 13 Recommended Cabling for TIA EIA422 or TIA EIA485 The COM1 port on the QuickPanel View QuickPanel Control provides connections to devices that support either TIA EIA422 or TIA EIA485 These electrical standards specify a differential signaling technique that provides high data rates long distances and good noise rejection The standards do not address signal encoding protocol connectors or cabling However certain characteristics of these devices interfaces should be considered to ensure reliable connections Connections Connect nodes in a daisy chain fashion Do not connect in other arrangements especially star The standards do not spec
56. necessary For installations where all devices are in the same cabinet and have the same ground potential between devices connecting Signal Ground between all the devices on the 422 485 network is adequate to ensure proper voltage levels at the devices However if there is a difference in ground potential between devices such as when the devices are in widely separated cabinets signal grounds on a 422 485 network should not be tied together The cable shield and signal ground should be connected together at only one device closest to the earth ground connection The signal and frame grounds of the QuickPanel View QuickPanel Control are capacitively coupled but in some devices these ground references are connected together Connect Signal Ground pin 7 to Frame Ground pin 1 and then to earth ground on the QuickPanel View QuickPanel Control only in the circumstance where the other devices separate their signal and frame grounds and the QuickPanel View QuickPanel Control is the only device with frame and signal ground connected to earth ground Shielded cable is required for compliance with CE Mark and FCC requirements The cable shield should be connected to the metal connector shell or by pin 1 of the QuickPanel 25 pin serial connector Shield and signal ground pin 7 of the 25pin connector or pin 5 of the 9 pin serial connector should not be connected directly together Do not connect Signal Ground pin 7 to Frame Ground pin 1
57. ogress dialog to finish or indicate the operation is complete If the View or Control applications are running see Shutdown in chapter 1 GFK 2507 Chapter 4 Detailed Operation 4 25 Universal Serial Bus USB The QuickPanel View Control has two full soeed USB v1 1 host ports A variety of third party USB peripheral devices are available Each connected USB device requires a specific driver The driver supplied with the QuickPanel View Control is for optional keyboard or mouse support other devices require the installation of custom driver software 5V Data Data GND USB Ports A A list of compatible devices keyboards USB mice compact flash cards etc may be found by visiting the GE Fanuc Support page accessible from http support gefanuc com Note These USB ports are defined as maintenance ports and are intended to be temporary connections used for configuration and upload download of software or data Use of a device in the USB port may compromise CE Mark and UL certifications Before using an application requiring the use of a USB device verify that the USB device installed in the QuickPanel View Control meets the desired agency certifications For compliance to UL1604 do not connect or disconnect while power is applied unless the area is known to be nonhazardous 4 26 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Ethernet
58. on The Make New Connection window appears Make New Connection Select 8 Dial Up Connection ae Direct Connection O Virtual Private Network PPTP Virtual Private Network L2TP O PPP over Ethernet PPPoE Type a name for the new connection 4 Choose a connection type Select Virtual Private Network to configure a VPN connection Select PPP over Ethernet for a PPPoE connection 5 Tap Next The VPN or PPPoE Connection window appears depending on the connection type y My Connection My Connection Host name or IP address PPPoE Service Name blank for any service Pt PO Select a device A TCPHIP Settings Security Settings TCP IP Settings Security Settings GFK 2507 Chapter 4 Detailed Operation 4 19 6 Enter the Host Name or IP address for a VPN connection or a PPPoE Service Name for a PPPoE connection You can configure your TCP IP Settings at this time if you wish 7 Tap Finish To change the default device properties 1 From either the Device or Modem dialog box tap Configure The Device Properties dialog box appears Device Properties Port Settings Call Options Baud Rate 19200 Data Bits ja Parity None Stop Bits fa Flow Control Hardware y Lise terminal window before dialing Lise terminal window after dialing Manual Dial In the Port Settings tab choose settings for all connection preferences 3 Ifthe connection is for terminal emula
59. ort on its side Right Side CF Port A CF card is inserted in this port with the card s front facing the back of the unit the narrow side slot on the card should be toward the top Note For full protection from electrostatic discharge peel off the paper label on the side of the CF card facing the bezel to allow contact between the card and the internal frame ground contacts on the CF connector The card should slide in easily To avoid damage do not force it The Copy Project to Flash Card utility described in chapter 2 lets you transfer Proficy Machine Edition projects between QuickPanel View Control units using CF Cards The CF port in the 8 QuickPanel View Control supports both 3 3V CF cards and 5V CF cards No Compact Flash cards are supplied with the QuickPanel View Control A list of cards and other devices that have been tested and are compatible can be found by visiting hitp support gefanuc com selecting the Operator Interface category and then selecting the QuickPanel View product name An optional CF card may be ordered using part number IC754ACC0512MEM Do not remove power while the system is writing to the CF card such as when copying a Proficy Machine Edition project Removing power while writing may lead to data loss and file or CF card corruption To ensure the system completes writing to flash and closes all files after file operations that were activated from the desktop allow the Windows file pr
60. ower off retention is the life of the battery DRAM 64 MB ROM 512 KB Boot loader Memory Expansion Slot CAS Latency 12 Address Lines AO to A11 Expansion Memory 64 MB IC754ACC64MEM Catalog Number 32 MB IC754ACC32MEM Expansion Ports Compact Flash Memory One slot Type I II supports 3 3V and 5V Optional CF Card 512 MB IC754ACC0512MEM Catalog Number FieldBus Universal Serial Bus V1 1 compatible USB 2 GFK 2507 Appendix A Specifications A 3 Communication Ports Speed Littlefuse part 154001 Serial COM2 ElA232C DP9P male Speed 300 bps 115200 bps Mounting hardware 4 40 screw A 4 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Environmental Operating Temperature 32 F to 140 F 0 C to 60 C Operating Humidity 10 to 85 non condensing Storage Temperature 4 to 158 F 20 to 70 C Storage Humidity 10 to 85 non condensing NEMA Rating 4 and 4x when mounted in a comparably rated NEMA panel NEMA 4 is approximately equivalent to IP66 visit www nema org Operational Vibration IEC 60068 2 6 10 57Hz 0 012 peak to peak displacement 57 500Hz 1 0g acceleration Operational Shock IEC 60068 2 27 15g 11ms sine wave Rated temperature limits refer to the ambient air temperature immediately surrounding less than 3 or 7 6 cm the QuickPanel inside the enclosure in which the QuickPanel is mounted Additional provis
61. presentation or warranty expressed implied or statutory with respect to and assumes no responsibility for the accuracy completeness sufficiency or usefulness of the information contained herein No warranties of merchantability or fitness for purpose shall apply The following are trademarks of GE Fanuc Intelligent Platforms Inc Alarm Master Genius ProLoop QuickPanel VersaPoint CIMPLICITY Helpmate PROMACRO QuickPanel View VersaPro CIMPLICITY 90 ADS Logicmaster PowerMotion QuickPanel Control VuMaster CIMSTAR Modelmaster PowerTRAC Series Six Workmaster Field Control Motion Mate Series 90 Series Three GEnet PACSystems Series Five VersaMax Proficy Series One Copyright 2008 GE Fanuc Intelligent Platforms Inc All Rights Reserved Notices All rights reserved No part of this publication may be reproduced in any form or by any electronic or mechanical means including photocopying and recording without permission in writing from GE Fanuc Automation Disclaimer of Warranties and Liability The information contained in this manual is believed to be accurate and reliable However GE Fanuc assumes no responsibilities for any errors omissions or inaccuracies whatsoever Without limiting the forgoing GE Fanuc disclaims any and all warranties expressed or implied including the warranty of merchantability and fitness for a particular purpose with respect to the information contained in this manual and the equipment or software describe
62. put device when working with Windows CE is the touch screen it can often be convenient to use keyboard shortcuts such as those described in the following table GFK 2507 Keyboard Shortcut Action CTRL ESC or 2 Opens the Windows CE Start menu Use arrow keys to select a program and ENTER to run it ALT TAB Starts the Task Manager Use it to quit unresponsive programs CTRL ALT Starts the touch screen calibration SPACEBAR Equivalent to single tap ENTER Equivalent to double tap In a dialog box equivalent to OK TAB In a dialog box select next control SHIFT TAB In a dialog box select previous control ESC Close dialog box discarding changes ARROW KEYS In a dialog box select controls or items from a list box To place a program in the Start menu 1 EL ae A O Start 2 Windows Explorer Navigate to the program you want to place in the Start menu Tap the program s icon to select it From the Edit menu choose Copy Navigate to the Windows Programs folder From the Edit menu choose Paste Shortcut To save the settings run Backup see page 2 11 Chapter 2 Overview 2 7 Pocket Internet Explorer Microsoft s Pocket Internet Explore is a fully integrated browser within the Windows CE operating system This browser allows you to connect with an Internet service provider view web pages and download from FTP sites Pocket Internet Explorer supports JScript Java support can be added from th
63. r additional licensing provisions Users are advised that a maximum of ten 10 computers or other electronic devices may simultaneously connect to access and use services of the Microsoft Windows CE Operating system on the QuickPanel View Control solely for remote access including connection sharing The ten connection maximum includes any indirect connections made through multiplexing or other software or hardware which pools or aggregates connections Note that the QuickPanel View Control does not provide any server functionality utilizing Remote Desktop Protocol RDP to remotely connected client computers or devices However it does support connectivity to a remote Microsoft Terminal Services server The server providing these services must meet these restrictions and other Microsoft licensing requirements as applicable Notices Notice Regarding Video Standards This product is licensed under one or more video patent portfolio licenses such as and without limitation VC 1 and MPEG4 Part 2 Visual for the personal and non commercial use of a consumer to 1 Encode video in compliance with the standards licensed under such patent portfolio licenses and or 11 Decode video that was encoded by a consumer engaged in a personal and non commercial activity and or was obtained from a video provider licensed to provide video under such patent portfolio licenses Such license extends to this product only and only to the extent of other
64. ry Code Area Code and Telephone number of the remote modem you will connect to 4 22 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 5 Tap the Emulation tab and choose an emulation type DEC VT 100 or TTY Generic Session Properties Communications Emulation Choose an emulation type CR gt CR LF SEC y T100 Inbound Outbound Auto detect y Automatic Scrolling Code page selection Wertical Local echo a Horizontal Use small font by default 6 From the Code page selection box select the coding type to employ 7 Select the Inbound and or Outbound check boxes to add LF characters to each CR 8 Select the Vertical and or Horizontal check boxes to specify automatic scrolling 9 Tap OK 10 The new session is added to the I Session window To save the settings run the Backup utility See page 2 11 GFK 2507 Chapter 4 Detailed Operation 4 23 To start a terminal session 1 From the Start menu tap m Programs then Communication and choose Terminal The Terminal window appears E de Make New My Session Session 2 Double tap the session you want 4 24 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 CF Port To enhance the QuickPanel View Control s capabilities with additional flash memory the unit is equipped with a CF Compact Flash Type 2 p
65. s These considerations could include shading for the QuickPanel and its cabinet with awnings or other solar opaque materials avoiding a due East or West facing of the cabinet providing ventilation or active cooling of the cabinet or other methods GFK 2507 3 1 Connecting a DC Power Supply 1 Using the three screw terminals shown in the following diagram attach a 24VDC 24W power supply to the plug supplied with the QuickPanel View Control see Appendix A Design Specifications for power supply and conductor size requirements 2 Insert the plug into the power supply socket and securely tighten the attaching screws Note The torque range for the attaching screws is 4 6 inch lbs Rear View Power Supply Socket Power Supply Plug Frame Ground OV 24 VDC 3 2 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Panel Cutout For enclosure mounting cut an opening in the panel according to the specifications Panel Cutout Height 7 34 0 050 0 0 186 4mm 1 27mm Omm Width 8 97 0 050 0 0 227 8mm 1 27mm Omm 7 34 Depth 3 03 76 9mm 186 4mm Bezel Dimensions Height 8 18 207 7mm Width 9 8 248 9mm Corner Radii 0 1 2 5mm max A Panel Thickness range 0 063 to 0 196 8 97 1 6mm to 5mm Oe 227 8mm Installation Notes The unit will not fit through the cutout with a compact fla
66. sh CF card inserted in the port The unit may not fit through the cutout with some cables attached depending on the cable s hood design To avoid gasket degradation limit repeated insertions or removals of the unit and retightening of the mounting clips For full protection always use a fresh gasket Replacement gaskets may be ordered using part number IC754ACCO8GAS GFK 2507 Chapter 3 Installation Procedures for Conformance and Compliance 3 3 Mounting Bracket Locations To secure the QuickPanel View Control to a panel use the six included mounting brackets They hook into openings located on the top bottom and sides of the housing Top View 3 4 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Mounting the QuickPanel View Control in a Panel 1 Verify that the gasket is properly seated in the bezel channel then insert the unit into the panel cutout without a CF card in the CF port 2 Insert the hook of each mounting clamp into the housing openings as shown below 3 Firmly tighten the clamp screws Note The torque range for the mounting clamp screws is 2 6 4 4 inch lbs 0 3 0 5 Nm The mounting clamps hold the unit in place by tension No drilling is required Do not damage the gasket attached to the back of the QuickPanel This gasket prevents shock hazards and damage caused by liquids accidentally entering the unit after installation Also lim
67. splay the time on the taskbar 1 From the Start menu choose LF Settings and then Taskbar and Start Menu Properties The Taskbar Properties dialog box appears Taskbar and Start Menu Proper OK General Advanced Auto hide Show Clock 1 Onthe Taskbar Options tab select Show Clock 2 Tap OK An hours and minutes display now appears in the taskbar Clock Display LEA 1 02 PM e 4 48 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Configuring SNTP There are two levels of Network Time Protocol NTP time servers available on the Internet First level time servers are primarily intended to act as source time servers for second level time servers First level time servers may also be capable of providing mission critical time services Some first level time servers may have a restricted access policy Second level time servers are intended for general SNTP time service needs and usually enable public access lt is recommended that you use second level time servers for normal SNTP time server configuration because they are normally located on a closer network that can produce faster updates It is recommended that you research any time server selection to ensure that it can meet your specific time server requirements More information and a list of SNTP time servers can be found at http support microsoft com kb 262680 If the time on the time server is more
68. tion select or clear the terminal related check boxes You can use the QuickPanel View Control to emulate a terminal attached via a modem link Hayes compatible to COM1 A terminal emulation definition is added as a unique session 4 20 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 To change the default TCPAP settings 1 Obtain correct TCP IP settings from your network administrator 2 From the Device Modem PPPoE Connection or VPN Connection dialog box tap TCP IP Settings The TCP IP Settings dialog box appears Clear the Use server assigned IP address check box 4 Enter the TCP IP settings from your network administrator and then click OK TCP IP Settings Use Slip Lise software compression Lise IP header compression GFK 2507 Chapter 4 Detailed Operation 4 21 To add a terminal session 1 From the Start menu tap m Programs then Communication and then tap Terminal The Terminal window appears File Edit View kl Make New Session 2 Double tap B Make New Session The Session Properties dialog box Communications tab appears Session Properties Communications Session name Wy Session Select a modem Hayes Compatible on COM2 Country Area code Telephone number 7 Force fi has long distance Dialing from Dialing Properties Force local 3 Inthe Session Name box type a name for your session 4 Enter the Count
69. trial Control Equipment Declaration of Conformity The agency approvals listed above and on the Declaration of Conformities are believed to be accurate however a product s agency approvals should be verified by the marking on the unit itself A 6 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Appendix B Diagnostics The tables contained in this appendix can be used to identify and remedy problems that can occur with the 8 QuickPanel View and QuickPanel Control products Power up Problem Suggested remedy Blank screen No power Check all power connections to the QuickPanel CE Backlight failed This is further indicated when the left LED glows red The LED will turn red if either backlight fails Backlight timer expired Touch the screen to reactivate Pocket Internet Explorer Problem Suggested remedy Cannot access any URL If you have previously set up an IP address on a local when using a dial up Ethernet Network it must be cleared Disconnect your connection to an ISP Ethernet cable and reboot Your ISP will reassign an IP address when you reconnect the cable GFK 2507 B 1 Physical Unit Problem Slow or sluggish touch response After adding expansion memory in the DIMM connector the system won t boot or if it does boot an error message is displayed Touch screen does not work reliably in corners or touch areas activate just outside their bord
70. ugh a power cycle Shutdown There are no specific dangers associated with a power failure or other unplanned shutdown of the QuickPanel View Control In general programs are retained in FLASH memory and user data can be retained in battery backed SRAM Some operating system settings are retained only with user intervention so in order to carry out a graceful shutdown of the QuickPanel View Control we recommend you perform the following procedure To shut down the QuickPanel View Control 1 Quit any programs that are running and wait for all file operations to complete To save changes to operating system settings e g brightness touch screen sensitivity run Backup When the Backup dialog box displays Completed Successfully remove power from the DC power supply connected to the QuickPanel 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Technical Support If you purchased this product through a GE Fanuc Authorized Channel Partner please contact them directly General Contact Information Online Technical Support and GlobalCare http support gefanuc com Additional information http www gefanuc com Technical Support If you have technical problems that cannot be resolved with the information in this guide please contact us by telephone or email or on the web Americas Online Technical Support http support gefanuc com Phone 1 800 GE FANUC 1 800 433 2682
71. uickPanel Control a few configuration steps are necessary To start the QuickPanel View Control 1 Apply DC power to the QuickPanel View Control Once power is applied the QuickPanel View Control begins initializing The first thing to appear on the display is the splash screen QuickPanel Control 05 Version Windows CE MET 5 00 Platform GuickPanel Control 2 00 Build 33 Loaded Restoring Files Please wait 5 2 To skip running any programs included in the StartUp folder tap Don t run StartUp programs The splash screen disappears automatically after about 5 seconds The Windows CE desktop then becomes visible 3 Tap Start point to Settings and then tap EXControl Panel E 4 Inthe Control Panel double tap Display to configure the LCD display 5 In the Control Panel double tap E Stylus to configure the touch screen GFK 2507 Chapter 1 Welcome 1 3 1 4 a a J 6 Inthe Control Panel double tap Date and Time to configure the system clock 7 Inthe Control Panel double tap gl System to configure a network machine name Many applications including Proficy Historian require a unique machine name It is recommended procedure to set a unique network name for the QuickPanel View Control to avoid future conflicts 8 Inthe Control Panel double tap amp 5 Network and Dial up Connections to configure network settings 9 On the desktop double tap ball Backup to save any new settings thro
72. uickPanel View Control To run the Backup program 1 On the desktop double tap Backup The Backup dialog box appears Backing Up Please Wait 2 Tap OK Completed successtully GFK 2507 Chapter 2 Overview 2 11 Storage Manager Use Storage Manager to repair or format lost or corrupted data volumes Storage Manager can repair data volumes existing either in Compact Flash CF battery backed SRAM BBSRAM or USB Flash Keys thumb drives Data volumes existing in the main flash file system of the QuickPanel may not be repaired by Storage Manager Storage Manager accessed from the Control Panel folder is a Microsoft product for which on line help is available Storage Properties Storage Manager 56 00 KB Unallocated 0 00 B Sector Size 312 00 B New Del 2 12 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 System Information System Information is a custom utility that displays a splash screen with the following information Operating System version For example Windows CE 5 00 Platform Identifies the host hardware its version and build number Tapping More Info on the splash screen opens the Advanced System Information window which provides information such as hardware version and serial number CPU type and specifications etc This information can be especially useful if you are contacting GE Fanuc Support To run the
73. ws CE It is divided into two areas of which only one is accessible from Windows CE Explorer The Flash Storage folder represents a 48 MB block of memory available for long term storage of user application programs Another 16MB block is used to store the Windows CE operating system and is not directly accessible from Windows CE Explorer The operating system and all user application programs are transferred from Flash to DRAM for execution Any user additions to the Windows folder are retained in Flash Storage when the ll Backup utility is run FLASH memory has a limited write cycle lifetime That is the physical memory devices wear out after approximately 100 000 cycles minimum so it is advisable to limit file operations such as copy delete etc The write cycle is much slower for FLASH than it is for other portions of RAM therefore FLASH is not recommended for the storage of program variables or any data items whose values are dynamic Flash memory can optionally be added with an external flash device such as a CF card or USB thumb drive These devices will appear as the PCFlash Storage folder 4 38 8 QuickPanel View and 8 QuickPanel Control Fully Loaded Color TFT September 2008 GFK 2507 Do not remove power while the system is writing to flash memory such as when downloading a Proficy Machine Edition project Removing power while writing may lead to data loss and file system corruption To ensur