Home

TCA 4100 Telephony Conformance Analyzer

image

Contents

1. Supported standards Acoustic and telephonometry testing of handset and hands free telephones opt ACU HATS HATS2 VolP and Digital telephones opt VoIP TIA EIA 810 A ETSI ES 202 737 DECT WiFI Bluetooth TIA EIA 810 B ETSI ES 202 738 2 TIA EIA 920 ETSI ES 202 739 TIA EIA 920 A ETSI S 202 740 TBR 10 EN 50332 Cellular telephones OGPP 1S 260 131 3GPP TS 20 142 3GPP2 C S0056 0 cdma 2000 3GPP TS 51 010 1 GSM 11 10 TIA 1042 2005 11 cdma 2000 ETSI EN 300 903 GSM 03 50 EN 50332 ITU T P 342 P 360 Analog telephones TBR 38 ANSI TIA 470 120 C ANSI TIA 470 110 C EN 50332 Hearing Aid Compatibility opt HAC FCC 68 316 and 68 317 HAC USA SIP protocol testing opt SIP EISI TS 102 0277 RFG 3261 Voice Quality Testing opt VAT ITU T P 862 P 862 1 International PEAQ Perceptual Evaluation of Audio ITU R BS 1387 1 Quality opt PEAQ Notes 1 Excluding High voltage surges overvoltage protection leakage current EMC safety environmental tests 2 Contact Hermon Laboratories for other available standards 3 Some standards are optional please consult with Hermon Laboratories 4 Requires opt TSYNC 20 HLTCA 4100 TELEPHONY CONFORMANCE ANALYZER Main tests Acoustics and Telephonometry sending and Receiving Sensitivity frequency response sending and Receiving Loudness Rating SLR ROLR RLR Receive Volume Control sending and Receiving Linearity sending and Receiving Disto
2. Wai Acqutonsetings Bemirion hardadi 0 00 Hr dwersging nieva 500 Tamala Furies Avieira Nome pe Couri iim Hf UD Composite HA 1014 1914 1914 dek in Syetmen signale 3 Setting test ranges Test Properties 5 2 2 Receive loudness rating RLR read only General Results Format Conditions Parameter Units Visible apply to suite Signaling reports On Microphone type T4195_OES_LL Mic stab delay 20 s Acoustic test setup Test head Stimulus level Stimulus level 16dBm0 Stimulus freq 200 4000 Apply leakage factor No Periods number 100 Averaging time 0 2 Condition 1 EUT state Handset position Minimum VC Stimulus file SOUNDS male wav Condition 2 EUT state Nominal VC Stimulus file SOUNDS male wav Condition 3 EUT state Maximum VC Stimulus file SOUNDS male wav OOOOUSsNONO K lt OO OOOOOOOOO K K K K f Condition Parameter es eaa es a 4 Setting test parameters 11 In addition to thousands of built in tests users can easily create new custom tests by setting the results format test parameters ranges limits EUT remote control commands user prompts and test execution sequence No programming or scripting is required Both system and user tests are grouped in test suites New test suites for new standards or user specifications can be created Test suites are used to access set and run tests and s
3. The nominal values of SLR to the POI shall be 8 3 dB Test mode Compliance Verdict Date amp Time 6 15 2009 5 37 07 PM PASS Temperature 25 C Air Pressure 1014 hPa Relative Humidity 48 Mains Power Supply 230 VAC 50 Hz Remarks CellPhone 2556 Measurement uncertainty Expanded Uncertainty k 2 95 confidence Sensitivity 0 65 dB Voltage vs time conditions 1 to 2 2 15 pm s 500 m 2 o 6 500m gt 1 15 2 1 1 i 1 1 i 1 500 m 15 2 25 3 3 5 45 Time s Result Condition 1 Stimulus file SOUNDS male wav Result Condition 2 Stimulus file SOUNDS harvardman wav Loudness rating Send loudness rating SLR Limit min Limit max Verdict Condition 1 Stimulus file SOUNDS male wav Pass 8 83 dB 5 dB 11 dB Pass Condition 2 Stimulus file SOUNDS harvardman wav Pass 9 38 dB 5 dB 11 dB Pass Run the tests automatically Generate MS Word reports for multiple standards Powerful display amp analysis Test results are continuously displayed on graphs and tables together with the current test status and verdict key test parameters user prompts the Current test point and measured values Time and frequency domain measurements with minimum maximum and average statistics are also provided For each test you can set which results will appear on the display and in the test report set limits Benefit trom real ti
4. ETSI Europe I ETSI TS 102027 SIP General L Generic suite TCA 4100 ITU T international i mu TP 862 P 862 1 VQT x Samples x Sample PBX Through transmission L TIA 968 A 4 Analog 2 wire SX TER Europe J TBR 10 DECT 7 Speech and tele 5 x User Suites 5 x Test EM Noise g Reports 8 System EE Clients W Network Simulation E Calibration Backup Restore Parameter configuration A Find 3GPP2 C S0056 0 v1 0 cdma2000 2005 07 modified 2 Electro acoustic requirements 2 1 Receive audio interface 2 1 1 Receive audio frequency response mandatory limit M Pass 2 1 1 Receive audio frequency response desired limit V Pass 2 1 2 Receive audio sensitivity M Pass 2 2 Send audio interface 2 2 1 Send audio frequency response mandatory limit M Pass 2 2 1 Send audio frequency response desired limit M Pass 2 2 2 Send audio sensitivity M Pass 2 2 3 Weighted terminal coupling loss V Pass ETSI TS 126 131 V4 2 0 NB 3GPP TS 26 131 2002 09 modified 5 Narrow band telephony transmission performance 5 2 Overall loss loudness ratings 5 2 2 Connections with handset UE 5 2 2 Send loudness rating SLR V Pass 5 2 2 Receive loudness rating RLR M Pass 5 2 3 Connections with Desktop and Vehicle mounted hands free UE 5 2 3 Send loudness rating SLR v Pass 5 2 3 Receive loudness rating RLR M Pass 5 2 3 Receive loudness rating RLR and volume control recommended C Notreq
5. IS 51 010 1 GSM 11 10 e 3GPP2 C S0056 0 e ETSI EN 300 903 GSM 03 50 e ITU T P 342 P 360 Cellular phone testing TCA 4100 cellular testing options include an Agilent 8960 Series 10 Wireless Communications Test Set that connects to the TCA 4100 audio interface providing a radio link with the cellular phone under test All current cellular technologies such as GSM CDMA WCDMA and CDMA2000 are supported with the Agilent 8960 options 16 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER Agilent 8960 can be configured and controlled by the TCA 4100 software enabling fully automatic testing Built in test suites according to main 3GPP ETSI and ITU T standards are provided with the cellular options Raaaae fre Gi tw F 1g VoIP phone testing Testing of VoIP enabled phones is fully covered by TCA 4100 Acoustic Voice quality Functional and Protocol testing Wi Fi handsets Soft phones USB and Bluetooth phones can be tested with various TCA 4100 options SIP Protocol Conformance testing SIP Conformance Analyzer is an advanced testing solution for SIP enabled products widely used in today s VoIP and 3G networks Comprehensive tests protocol simulation and analysis tools verify SIP compliance according to ETSI TS 102 027 RFC 3261 ensuring high probability of interoperability Offering a full suite of over 600 test cases the SIP Conformance Analyzer is an automatic conformance testing solution that
6. R amp D QA and production testing of phones Voice Quality Testing PESQ Voice Quality Testing VQT utilizes PESQ Perceptual Evaluation of Speech Quality algorithm to assess the voice quality of telecom equipment and networks The PESQ algorithm defined in the ITU T P 862 recommendation models human perception of speech by comparing a reference speech signal with the degraded signal The reference signal is transmitted by the test instrument to the EUT Equipment Under Test and the degraded signal output by the EUT is measured by the test instrument The most important result is the ITU T P 862 PESQ MOS Mean Opinion Score because it directly expresses the voice quality The PESQ MOS ranges from 1 0 worst up to 4 5 best Additional results such as Delay and Delay Jitter G 107 rating R factor various waveforms level gain loudness SNR VAD Voice Activity Detection parameters Front End Clipping Hold Over Time and Drop outs are also provided Of particular interest is speech quality assessment and analysis of compression and VAD codec s such as those utilized in VoIP and wireless networks PESQ VQT can replace an array of lengthy traditional TIMS voice frequency measurements PESQ evolved from the need to automate the human listening tests as defined in ITU P 800 and has introduced improvements to the older PSQM PSQM and PAMS methods The VQT measurements can be perform
7. The TCA 4100 provides a fully automated amp affordable voice quality and acoustics conformance test solution according to major world wide standards This highly integrated test system provides the hardware and software required for testing almost any type of wire line and wireless phones electro acoustic and audio devices The system can be optionally configured with a VoIP software interface analog PSTN interface cellular RF base station simulator wireless DECT Wi Fi base stations Bluetooth wireless interface and 4 HLTCA 4100 TELEPHONY CONFORMANCE ANALYZER acoustic interfaces such as HATS Head and Torso Simulator or a test head The interfaces are calibrated together and automatically controlled by the system software Designed for R amp D test labs and high speed production testing the TCA 4100 powerful manage ment and automation features simplify and shorten the testing cycle ff Test Suites Standard Suites jects 14316 Native Codes Ltd CellPhone 255 14315 Native Codes Ltd CellPhone poe 14317 Native Codes Ltd CellPhone 655 gC ANSI TIA USA 0 ANSI TIA EIA S10 A NB digital te Cellular TCA 4100 a 3GPP2 C S0056 0 v1 0 edma200 ETSI EN 300 903 GSM 03 50 V8 TIA 1042 cdma2000 2005 11 o ETSI Europe gO ETSI TS 102027 SIP f ral 0 Generi O ITU T internation gD mTu TP 862 P 862 1 VQT Sample PBX Through transmission TIA 968 A 4 Ana
8. e Emergency recovery of all software and factory data from an image disk supplied with the system e Quality Assurance issues have been thoroughly addressed aa ISO IEC 17025 compliant test Relative sensitivity used imit Ei Limit reports X Start Yi Start Y1 Stop Y2 Start Y2 Stop Y Pass Criteria X Pass Criteria i uency Hz lative sensitivity dB Tests test suites projects and E E es Ere ME reports are uniquely identified l A ee P 1000 6 Yl lt y lt Y2 None Changes to test definitions are 2000 6 Y1 lt y lt Y2 None 3000 9 Y1 lt y lt Y2 None recorded 3400 Oy lt Y1 Nore TCA 4100 comes with calibration according to ISO IEC 17025 T Limits by condition ERR PAARI E Limit type Limit x eee Py oye result Versatility and ease of use EPE a preview y Logarithmic ie fo The TCA 4100 features the familiar Windows user interface Test suites test projects tests reports and other data and tools are presented in Windows Explorer like tree list views Copy Paste Y Param format Intuitive commands such as Open 2 Setting limits New Delete Save Find Properties and data operations are implemented through double click menus toolbar icons and right mouse button context sensitive pop up menus 10 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER General Resuits Format Limits Cominons Ranges Rangert vi Frequency 10 00 bir 20 100 kez Seat Hr eo Hr Promi
9. 102 027 Audio and Voice Frequency Testing single port referenced to pre recorded signals e g on MP3 Frequency Response players and dual port measurements over the following THD N transmit receive ports Phase 4 audio analog FXS acoustic mouth or ear simulator Crosstalk La Signal to Noise Ratio eee Jitter 4 Level Voice Quality Testing PESQ Perceptual Evaluation of Speech Quality testing over a combination of the following TCA transmit receive ports analog FXS acoustic mouth or ear simulator VoIP Off line analysis of degraded vs reference wav files with on line analysis and recording to wav file s Including the following measurements PESQ MOS per ITU T P 862 and MOS LQO per ITU T Attenuation Loudness P 862 1 AGC measurements Delay and delay jitter VAD Voice Activity Detection performance analysis Reference and degraded signal level and loudness with Front End Clipping Hold Over Time Hang Over Time aligned and non aligned waveforms R factor ITU T G 107 e model i evOpeu Audio Quality Testing PEAQ Perceptual Evaluation of Audio Quality testing over the Modulation changes loudness of distortions Linear TCA audio interface including the following measurements distortions Bandwidths of Signals Frequency of audible Objective Difference Grade ODG distortions Noise to mask ratio Detection probability Distortion Index DI Harmonic structure of error TOSQA TOSQA Telecommunica
10. CA 4100 achieves and even surpasses the accuracy required by the supported standards through careful hardware amp software design testing automation and by taking into consideration various signal path factors and automatic self calibration amp extensive calibration procedures Signaling TCA 4100 built in Signaling Signaling can be used for two purposes provides a powerful set of tools found in standalone network line 1 Functional testing of different Different networks switches and and switch simulators It allows you analog VoIP signaling features at CEs Customer Equipment can to perform simulation and analysis various network conditions with be simulated by programmable of various analog and VoIP signals built in pass fail criteria timing network conditions and call conditions and messages that are and signal measurements scenarios Sequences of test cases used in telecom networks with transmitted and expected 2 Establishing a voice commu nication path with the EUT before performing various tests e g TCA 4100 can originate a call between a PBX line and VoIP ex tension and then perform an inter A database of pre defined signals modulation distortion test between messages and signaling sequences these two ports used in multiple countries is provided received signals and messages delays timeouts IF THEN GOTO cases remote EUT control and pass fail criteria can be defined Signaling procedur
11. For handset headset and hands free devices testing Opt HATS2 same as Opt HATS plus left ear simulator Opt HAC Hearing aid compatibility test option Includes two magnetic field antennas interconnecting cable Opt TSYNC Includes hardware and software for dual port time synchronized measurements such as phase jitter and PEAQ Opt ANR Includes 4 port audio card and four external speakers for Ambient Noise Rejection test Opt PESQ PESQ voice quality testing ITU T P 862 MOS Opt TOSQA TOSQA voice quality testing Opt SIP SIP protocol testing over 10 100 Base T Ethernet interface per ETSI TS 102 027 RFC 3261 Opt DECT DECT interface for acoustic and telephonometry testing of wireless DECT handsets Includes external DECT base station that connects to the Analog PSTN interface Opt WiFi Wi Fi interface for acoustic and telephonometry testing of wireless Wi Fi handsets Includes external Wi Fi base station that connects to the Ethernet port Opt Bluetooth Bluetooth interface for acoustic testing of Bluetooth headsets and hands free sets Includes external USB Bluetooth adapter Cellular options Acoustic and telephonometry testing of GSM CDMA WCDMA CDMA2000 cellular telephones Includes external cellular base station simulator Consult with Hermon Laboratories on the cellular interface specification Options ALG and Bluetooth must be factory installed All the options can be installed toge
12. Hz 3A 100 V 1 5A 240 V 460 W maximum with all options installed and including the external monitor Environmental Conditions Temperature Operating sinoda STUIT AAAA E E Relative Humidity OPOrAatinG sccceccsescsscscescsescseeseseseseeees ONCE scncespsaveseanstenntesseniesetarasmaenpeies rene Altitude Opera UNO ananas SJONE 2 AAA E OEE Regulatory Compliance ALCL siaricuteessarossaprarnenticntatieasntateanetetautmans Dimensions 483 mm W x 133 mm H x 400 mm D Without accessories Weight a Olio U 10 C to 60 C 30 to 80 10 to 85 up to 10 000 feet 3 048 meters up to 31 500 feet 9 600 meters EN 61326 FCC Part 15 Class A IEC EN UL 61010 1 15 kg with all the options installed without external accessories Ordering information TCA 4100 Telephony Conformance Analyzer Includes instrument mainframe with operating software MS Windows XP Professional OS MS Office Basic factory installed and on line User Manual At least one of the following options must be ordered Opt ALG For connection of analog terminal equipment Used in acoustic and Voice Quality testing Opt ACU Acoustic and Telephonometry testing Includes external test head for handset fixation with ear simulator and mouth simulator Opt HATS Acoustic and Telephonometry testing Includes Head and Torso Simulator HATS with built in mouth simulator ear simulator right ear and handset positioner
13. P phones SIP and H 323 e Wi Fi handsets e Soft phones e DECT phones e Bluetooth hands free and headsets e USB phones and adapters e Analog telephones e Cordless telephones e Hearing aids e Audio devices Acoustic and Telephonometry Testing Acoustic tests are performed to assess electro acoustic performance speech quality of phones and to verify compatibility with other phones and communication networks Various characteristics of a phone are tested over its electro acoustic path between the phone s interface microphone speaker and line wired or wireless Handset phones are placed in HATS Head And Torso Simulator or in a test head which provides the reference standard positions from the built in ear and mouth simulators The ear and mouth simulators are connected to the TCA 4100 internal input preamplifier and output power amplifier 14 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER Hands free phones should be tested in a quiet environment such as an anechoic chamber with a test head that has a hands free positioner or with HATS depending on the standards Tests are performed according to procedures and specifications defined in ITU T ETSI TIA and other standards User defined tests can also be performed Coupled with other testing capabilities such as signaling functional testing and simulation SIP VoIP protocol conformance testing the TCA 4100 is a comprehensive tool for conformance
14. R BS 1387 covering the applicability to high quality audio signals with sampling frequencies of 44 1 48kHz SIP Conformance Analyzer Features e Fully automatic testing of SIP protocol RFC 3261 according to ETSI TS 102 027 e TTCN 3 suites for User Agent Proxy Redirect server Registrar e Tests for valid invalid and inopportune SIP protocol behavior and syntax variations e User friendly test parameter PICS PIXIT values setting e User configurable tests suites e On line and off line analysis e Real time display of protocol traces and test results e Logging of trace and results to file e Automatic test reports in text and MS Word format SIP Conformance Analyzer 17 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER TCA 4100 test configuration examples Bluetooth headset testing DECT telephone testing Wi Fi handset testing VoIP EUT USB voice EUT FF p Opt Bluetooth Opt DECT Opt WiFi USB LAN USB LAN LAN USB USB GPIB controller Hands Free testing Mobile phone testing TCA 4100 TELEPHONY CONFORMANCE ANALYZER Opt Hands free Hearing Aid Compatibility testing Cellular base station simulator Cellular options Analog telephone testing Opt HAC Magnetic field antennas Test head opt ACU Head and Torso Simulator opt HATS HATS2 18 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER 19 HLTCA4100 TELEPHONY CONFORMANCE ANALYZER SPECIFICATIONS
15. Telephony Co ACOUSTICS AND VOICE QUALITY CONFORMANCE TESTING FOR MOBILE WIRELINE AND WIRELESS PHONES m L E EXPERTS IN GLOBAL COMPLIANCE SOLUTIONS HERMON LABORATORIES TEST WHAT YOU HEAR Applications e Cellular phones e VoIP phones SIP and H 323 e Wi Fi handsets e Soft phones e DECT phones e Bluetooth hands free and headsets e USB phones and adapters e Analog telephones e Cordless telephones e Hearing aids e Audio devices e MP3 and CD players e Compliance testing e Compliance testing according to major world R amp D testing Standards e QA testing Fully automated testing amp documentation Production testing Built in standards and general purpose tests supports signaling and remote EUT control User defined tests test Suites and projects Manual operation for development and debugging testing Comprehensive online help Powerful management display and analysis features Modular design tailored to your needs HERMON LABORATORIES TCA 4100 TELEPHONY CONFORMANCE ANALYZER Key Standards e TIA EIA 810 A B e TIA EIA 920 A e TBR 10 e ETSI ES 202 737 740 e 3GPP ETSI TS 26 131 26 132 e 3GPP TS 51 010 1 GSM 11 10 e 3GPP2 C S0056 0 e ETSI EN 300 903 GSM 03 50 e ITU T P 342 P 360 e ETSI TS 102 027 RFC 3261 e PESQ ITU T P 862 P 862 1 e And more Acoustics and voice quality conformance testing for cellular digital and analog phones
16. ameters for debugging and development testing Measured results analyzed with zoom peak search and markers Programmable signaling and remote EUT control for fully automated testing User annotations and automatic Time amp Date stamp 9 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER Lab in a box TCA 4100 is not just a test instrument It is also a highly integrated system of tools amp features for performing and supporting tasks required in a test lab such as Test Properties 5 4 1 Handset and headset UE sending e Definition and management of test Result X Y specs and test plans with customized a Time 6 or N user prompts remote EUT control Time domain at freq Time s Voltage V commands and automatic test crea Ree selection criteria sent o a ee e Running and management of test ey mA projects aa Sold Soin e Generation and management of test me reports Conds graph Line Style Point Style Scales Report Voltage vs time 4 Solid Simple Dot e Integral client information database linked to test projects Result Show limit X Alignment Y Alignment Report e Integral database of network signals oo ae eg simulations and signaling that can Relative sensitivity A Center Top Center Top be used in tests e Built in calibration tests e Backup and restoration of all data as well as restoration of factory data
17. e Name VolP Incoming call TCA gt TE Name automatically Ports Pa Port Configuration ch Off ch B Off 1 5M 2M Off VoIP Measurement z Mat Tx port VolP Rix port Acoustic Test type NA 7 Signaling Fae ae Display only events with verdicts ES Load Save Copy Encoding T ables E inher eara Time after T Conditions Start of signaling VolP None sip 10 0 0 2 VolP None 2 VolP Command Repest a call VoIP None VoIP Delay 1s VoIP None 0 T gt 1F 1 0 0000p Event m Condition Add Delete Duplicate Add Encoding Tables x Duplicate C DIME ME MFC Proaress tones amp Rinas ABCD bits signals CID SMS Rx only Minimum level Minimum On time Minimum Off time 20 H v 7 40 ms 40 ms Tx amp Rx Tx only A Tone name Freq1 Hz Freq2 Hz Level Level2 Levelunits Ontime s Off time s DTMF 1477 9 dBV 0 08 0 08 1209 9 dBV 0 08 0 08 1336 9 dBV 0 08 0 08 1209 9 dBV 0 08 0 08 1336 9 dBV 0 08 0 08 1477 9 dBV 0 08 0 08 1209 9 dBV 0 08 0 08 1336 9 dBV 0 08 0 08 a 0 1 2 3 4 5 R AATT a Anw nno nno Je Reload system signals 13 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER Supported Equipment Handsets Headsets and Hands free phones such as e Cellular phones GSM CDMA WCDMA CDMA 2000 e VoI
18. ed between any two TCA 4100 interfaces e g between acoustic and VoIP interface The analysis can be performed on line and off line comparison of pre recorded files Received voice signals can be recorded to wav files Voice Quality Testing TOSQA TOSQA Telecommunication objective speech quality assessment is an intrusive objective voice quality measurement method developed by Deutsche Telekom TOSQA supports only narrowband electrical recording while TOSQA2001 adds wideband and acoustic recording Support Similar to PESQ this method uses pre recorded files that are transmitted to EUT input recorded on EUT output and then compared Primary outputs of this method are TOSQA value O to 100 more is better and TMOS 1 to 5 more is better according to ITU T recommendation P 800 Another quality parameter provided by TOSQA is the estimated Equipment Impairment Factor IE for E Model according to the ITU T G 107 recommendation Key features e PESQ MOS per ITU T P 862 e Codec VAD testing e Delay and Delay jitter e Fully automatic measurements with built in signaling e Automatic reading recording from to one or auto incremented files e On line and off line analysis e Real time display of results and degraded versus reference waveforms 15 HLTCA 4100 TELEPHONY CONFORMANCE ANALYZER Standards e GSM e CDMA e UMIS e WCDMA e CDMA 2000 Standards eo 3GPP Elsiis 26 lel SCP els IS 20192 e 3GPP
19. erve as templates for new suites and projects A project provides the tools to run and manage tests and store amp document test results A project is created from one or multiple test suites inheriting all their definitions It contains all necessary information required for a test project e Details of the product under test e Client details e Project performance information e Test specification group of test definitions created from one or more test suites You can modify the test specification in the project and save the project test specification as a test suite to be used as a template in other projects and suites e Project and tests status including the verdict e Test results are saved for each test execution in the project You can Select which results will be included in the test report Generate test reports in Microsoft Word format for each test suite included in the project Open print and delete test reports from the project Include Microsoft Word documents in a test suite or in a project to document unsupported tests or to include additional information in a test report HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER Professional on line tecn support and training for both Novice and advanced users On line help and support TCA 4100 features a comprehen sive context sensitive online help with examples and step by step guidance The tests are thoroughly docu mented
20. interface Audio frequency generator output CONNECHON esisiini LEMO type female 2 pin Connects to external mouth simulator speaker Measurement input CONNECHON cccscssssssssssseseeseeen LEMO type female 7 pin Connects to external ear simulator right ear microphone Second measurement input CONNEC OF esisiini LEMO type female 7 pin Connects to external ear simulator left ear microphone Low sensitivity measurement input CONNEC OF vse LEMO type female 7 pin Connects to external ear simulator microphone VolP Ethernet test interface opt VolP One of the Ethernet LAN ports See below SIP H 323 Codecs G 11 G 722 G 726 G 723 G 729A GSM FR iLBC signaling protocols 22 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER PC interfaces SVGA output Connects to external monitor supplied with the system Connector Ype HD15 female USB USB 2 0 compatible Connector type Eight standard USB ports Parallel Connector Ype DB25 female Ethernet LAN 10 100 Mbit s NIC Two ports Connector Ype RJ 45 female Audio output Line input Microphone input Audio interfaces AC 97 Audio Codec compatible Connector TYPES 3 5 mm stereo jacks Keyboard Connects to external keyboard Connector Ype PS 2 female Mouse Connects to external mouse Connector Ype seisein PS 2 female Built in PC Intel Core 2 Duo CPU 1 GB RAM Internal 160 GB hard disk General Power requirements 100 240 V AC rms 50 Hz 60
21. log 2 wire II TER Europe IO TER 10 DECT 7 Speech and tele ET v4 2 0 gt 5 Narrow band telephony trans a Fully automated testing TCA 4100 comes with test suites ready for testing according to the supported standards Tests can be performed automatically either one by one or in a sequence No user interaction is required except for the setting of Equipment Under Test EUT in response to prompts appearing on the screen Completely unattended testing is possible for equipment that can be remotely controlled by signaling or ASCII commands Programmable signaling procedures allow call establishment with the EUT during tests and measurements The EUT can also be controlled by programmable ASCII commands over the LAN USB Serial or GPIB interfaces 2 2 2 Send audio sensitivit 3 Weighted terminal coupling loss 2 2 3 Weigh a eros aka i mission performance ting RLR with Desktop and Vehicle mounted hands free a 5 2 5 Receive loudness rating RLR 5 3 Idle channel noise handset and headset UE 5 3 1 5 3 1 Sending Recommended Note 2 5 3 2 Receiving No user controlied receiving volume control is provided 6 15 2009 2 03 09 PM 6 15 2009 2 02 34 PM 6 15 2009 2 01 54 PM 6 15 2009 1 57 15 PM 6 15 2009 11 08 26 AM such functionality together with the Capability to define custom tests and test sequences Is especially useful for production testing Reports are automatically generated in Microsoft W
22. me number of plots per graph style and color of each plot select Log or Linear axis set axis scale or select auto scaling select which test parameters will appear in the test report rename test results add comments and environment conditions description to test results Measured results can be analyzed by using markers delta markers Zoom in out max min peak search scroll and pan graph features Further analysis is possible by copy pasting the results to the preinstalled Microsoft Excel measurements and display IN R amp D applications Manual operation Besides fully automated testing capabilities the TCA 4100 provides on the fly control of test parameters and manual tuning and stepping which is important for development and debugging testing Test execution can be paused resumed automatically Swept or manually stepped through multiple test ranges A test can run once or continuously at single or multiple test points e g frequency ae 7 m Tesi TM MEA 4 5 8 2 2 1 Pulte shape A B751 Native Codes Lid Aten Se ER n low pp BS oni X Mode re o Cadin i Festive puist shape lad ratin Negative puise hope Lal ratio Rate Ratio es x CES S Min pos Manor ba mer Pes pule vege Hin neg ouise vege Mar neg pulse vitage Leek wry UM fax Mni seg poak Max reg pao Di SV lev 26 7 HLTCA 4100 TELEPHONY CONFORMANCE ANALYZER Next generation testing Tests repeated for multi
23. ord format providing test results and all information required for a test project Deciding what standard s tests are applicable for a particular product can sometimes become a complicated task Predefined and user defined criteria for quick selection of the required tests simplify this task The tests are automatically selected by answering Yes No questions about the functionality supported by the product Tests can also be manually selected A test can be automatically repeated with different or identical sets of test parameters and limits TCA 4100 comes with ore detined test suites according to tne supported standards Run Automaticaly Project Properties gt 5 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER HTca File Edit View Tools Help Getting Started 5 ig Projects fJ 14316 Native Codes Ltd CellPhone 255 fq 14315 Native Codes Ltd CellPhone 421 fq 14317 Native Codes Ltd CellPhone 655 Test Suites 2 Standard Suites ANSI TIA USA LJ ANSI TIA EIA 810 A NB digital te LJ ANSI TIA 810 8 NB digital teleph ANSI TIA 920 A WB digital telepk L T1A 920 WE digital wireline telepk 30 Cellular TCA 4100 E 3GPP2 C S0056 0 v1 0 cdma200 L ETSI EN 300 903 GSM 03 50 V8 ED ETSI TS 126 131 V4 2 0 NB 3GPP XJ ETSI TS 126 131 V5 2 0 NB amp WB XJ ETSI TS 151 010 1 3GPP TS 51 0 ZX ITU T P 342 2000 Handsfree ace J TIA 1042 cdma2000 2005 11 x
24. ple settings configurations Current results user prompts and overall test verdict displayed continuously Multiple result plots with user defined colors and styles displayed on a single or split screen in Time Frequency Amplitude and Phase domains User defined limit lines and masks Linear or Log X and Y axis Multiple numeric and status results with limits and verdicts displayed in a table 8 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER Test execution paused resumed automatically swept or manually stepped tuned or run continuously at single or multiple test points e g frequency p ests CA 4100 Acoustic tes jandset and headset UE receiving I fl Test 5 4 2 Hanc i Fle g t Run Toots tico lg a es xE Mode Comphance v Condition a RLR 8 50 dB Receive I0 dness rating KIR 9 4 cet P Tx amp Rx Setup Agiert 960 int 4100 E sa STIMULUS Stiemdus freq _ _ Sima _ __ Stirnmudus fle souns mse ww H Pass gt Tx Time Tx Event Rx Event Rx Time s Tx Time Tx Event Rx Event Rx Time Verdict 5 248 s Command Start of sgnaing 2 7 8715 VoIP Cal sip 10 0 0 2 3 VoIP Connected to 11 126s Pass Detected s 12 1275 Delay 15 Limit min 2 d8 Limit max 10 d Relatve sensitivity Limit min Limit max Verdict 100 Hz 26 01 dBPa V 28 83 B 29 65 dB 25 C On the fly control of test par
25. rtion sending and Receiving Noise sidetone and Sidetone Masking Rating STMR sidetone delay sending and Receiving Delay spectrum Analysis with stimulus sound Pressure Level SPL Instability and Howling Echo return loss Terminal weighted coupling loss single talk amp double talk TCLwst amp TCLwat Acoustic shock protection Ambient Noise Rejection Voice Quality Testing of handset and hands free terminals see Voice Quality Testing Hearing Aid Compatibility Magnetic field intensity Induced voltage frequency response Hearing aid compatibility volume control Voice over IP Acoustics and telephonometry tests of handset and hands free VoIP terminals See Acoustics and Telephonometry Voice Quality Testing See Voice Quality Testing VoIP spectrum analysis and signal generation VoIP signaling analysis Call simulation and analysis of SIP and H 323 Programmable Call Answer Disconnect Playback and recording of wav files Programmable received event masks and if then go to conditions for flow control of the simulation execution and verdict setting Programmable user messages user verdicts and remote commands for EUT automatic operation Pre defined and user defined database of signals and encodings Through transmission tests 2 SIP protocol conformance testing Conformance testing of SIP Session Initiation Protocol defined in RFC 3261 over 10 100 Base T Ethernet interface per ETSI TS
26. significantly reduces testing time and facilitates problem identification and debugging SIP Conformance Analyzer is provided as an option for the TCA 4100 Analog phones testing The analog telephone test option opt ALG provides a comprehensive solution for electro acoustic Telephonometry voice quality and functional testing of analog telephones Built in variable complex terminations artificial lines series resistance loop feed DC voltage on hook off hook progress tones DIMF rings together with the other signaling features allow for the simulation of various analog telephone networks Audio testing Audio devices such as MP3 players CD DVD players amplifiers speakers microphones and sound cards can be characterized with built in tests such as Level Frequency response Gain THD N Phase Jitter Crosstalk and SNR Audio quality testing PEAQ Perceptual Evaluation of Audio Quality provides accurate and repeatable estimates of audio quality degradation occurring through e g coding procedures It compares the audio signal input to a device under test DUT with the corresponding degraded audio signal output from that device on a perceptual basis Widely used for active testing in lab environments PEAQ measurement has achieved a great reputation for its ease of use and reliability of results while avoiding the costs for expensive and time consuming listening tests PEAQ is fully compliant to ITU
27. tates Acoustic signaling Yes KAKA Create a test project from multipole standard suites 14316 Native Codes Ltd CellPhone 2556 v Condition 1 Stimulus file SOUNDS male wav Completed E Loudness rating Send loudness rating SLR Condition t Stimulus file SOUNDS male wa 8 83 dB 2 Stimulus file SOUNDS harvardman way 9 38 dB E Condition E Sensitivity Frequency E Condition 1 Stimulus file SOUNDS male way 200 Hz 250 Hz 315 Hz 400 Hz 500 Hz 630 H7 CellPhone 2556 Complete testing and documentation required by Standards and regulatory agencies in a matter of hours Limit min 5dB 5dB Sending sensitivity 22 34 dBV Pa 23 22 dBV Pa 20 39 dBV Pa 17 79 dBV Pa 16 12 dBV Pa 14 47 ARV Pa 6 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER HERMON LABORATORIES Test specification Test purpose Select the required tests features Mi b Run Meas only RA Tx amp Ax Setup Agilent 8960 init 4100 E fa ja STIMULUS Stimulus freq Stimulus level Stimulus file Date of Issue 6 15 2009 5 2 2 Send loudness rating SLR To verify the send loudness rating SLR as the conversion ratio of a defined acoustic signal based on the product at the mouth reference point MRP to the transmit signal at the Point of Interconnection POI The SLR calculates according to ITU T Recommendation P 79
28. ther Recommended accessories External 17 or 19 LCD color monitor External keyboard and mouse External USB DVD RW For backup restore and emergency software and factory data recovery External USB to GPIB For control of external GPIB test equipment controller 23 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER HERMON LABORATORIES Since 1986 Hermon Laboratories TI Ltd HaTachana St RO Box 28 Binyamina 30550 Israel Tel 972 4 6268450 Fax 972 4 6268498 Email sales tca hermonlabs com www hermonlabs com Local representatives and sales offices are located throughout the world To find the most convenient one visit www hermonlabs com Copyright 2009 Hermon Laboratories TI Ltd All rights reserved Product specifications and descriptions in this document are subject to change without notice Product and brand names are trademarks of their respective owners Head and Torso Simulator HATS presentations are courtesy of Bruel amp Kj r Sound amp Vibration Measurement A S Cellular base station simulator presentation is courtesy of Agilent Technologies Inc P N 410001 903 A2
29. tion Objective Speech Quality According to TOSQA electrical measurement and TOSQA Assessment testing 2001 acoustic and electrical measurements over a combination of the following TCA transmit receive ports analog FXS acoustic mouth or ear simulator VolP with on line analysis and recording to wav file s Off line analysis of degraded vs reference wav files Including the following measurements TOSQA value TMOS value Equipment Impairment Factor le Delay 21 HL TCA 4100 TELEPHONY CONFORMANCE ANALYZER Test Interfaces Analog PSTN interface opt ALG One Analog 2 wire FXS test port with Off hook LED indicator EE O EAE AT Two 4 mm banana jacks Output loop feed voltage n 48 Vdc Maximum loop current 120 mA DENIES TE SANE nsa 400 Q 10kQ with 10 Q steps Termination 600 Q 900 Q 270 Q 750 Q I 0 15uF 82 Q 600 0 068uF 220 Q 820 Q II 0 11 5uF 370 Q 620 Q II 0 31uF Artificial Ne 0 2 7 km 4 6 km Per ANSI TIA 470 100C 4 3 6 CPE load simulator According to ANSI TIA 470 100C 4 3 7 Audio interface Audio frequency generator output CONMECION rsisi BNC female MEEO E 1Q Maximum output voltage 14 Vpp Frequency range 10 Hz 20 kHz Measurement input DONMCC ION wcsevevenreeunuyeneeneanenaseress BNC female IMPOCANCE ccecsssssserseusssrssersvanens 100k Q Maximum input voltage 2 Vrms Frequency range 10 Hz 24 kHz Acoustic
30. uired 5 2 4 Connections with handheld hands free UE 5 2 4 Send loudness rating SLR M Pass 5 2 4 Receive loudness rating RLR M Pass 5 2 5 Connections with headset UE 5 2 5 Send loudness rating SLR Pass 5 2 5 Receive loudness rating RLR M Pass 5 3 Idle channel noise handset and headset UE 5 3 1 Sending M Pass 5 3 1 Sending Recommended Note 2 M Pass 5 3 2 Receiving No user controlled receiving volume control is provided M Pass 5 3 2 Receiving Volume control is provided M Pass 5 4 Sensitivity frequency characteristics 5 4 1 Handset and headset UE sending M Pass M Pass 5 4 2 Handset and headset UE receiving General Specification 6 15 2009 1 56 Condition 6 15 2009 1 54 6 15 2009 11 0 Is the EUT a handset mobile telephone Run Automa Is the EUT intended for use as handheld Enable testing of recommended dauses H Eil Reauirement Condition 14317 Native Codes Ltd CellPhone 6553 ETSI TS 126 131 V4 2 0 NB 3GPP TS 26 131 2002 09 Is the EUT a desktop and vehide mounted hands free UE hands free UE Is the EUT intended for use with headset Does the EUT provide user controlled receiving volume control Test 5 2 2 Send loudness rating SLR le Edit Run Tools Help pak X Mode Compliance e Back gt oh X Project 14316 Native Codes Ltd CellPhone 2556 7 D 14316 Native Codes Ltd CellPhone 2556 Status Pass completed Test Run Status a EUT S
31. with EUT connection and configuration instructions test specification and measurement uncertainty data TCA 4100 user interface accommodates the needs of both novice and advanced users Step by step wizards are provided together with straightforward shortcut operations Remote configuration user guidance and training can be provided over the internet via remote operation of the TCA 4100 Hermon Laboratories customer support is comprised of a professional team of engineers knowledgeable about the equipment operation and standards Low cost of ownership TCA 4100 comes with a price significantly lower than the total cost of equipment and systems it can replace such as a digital oscilloscope spectrum and network analyzers digital transmission and jitter analyzer 12 HLTCA 4100 TELEPHONY CONFORMANCE ANALYZER line and cable simulators power supplies protocol frame signaling analyzers various test bridges and a PC Achieving automation requires further investment in integration and software development or buying expensive third party solutions Modular design and upgradeability TCA 4100 offers a modular design enabling you to buy only what you need You then have the flexibility to upgrade the instrument later for additional options Testing capabilities are easily extended to cover new standards by defining new user test suites using the GUI or by obtaining updates from Hermon Laboratories High Accuracy T