Home

DS100 User Manual

image

Contents

1. rr DS100 User Manual ID NO0 1 Name Autumn Verify PWD Verified When the device displays password error you need to input the password again Employee can try another 2 times by default The repeated times can be set in 4 5 Interface Option If it fails after 2 times return step 1 directly 3 Card Matching Step 1 Wave the card near to the card sensor area after the device find the card removes the card Step 2 When the device says Thank you the certification completed ID NO 29 Name Verify Card Verified The card verification and FP verification can be used by the same time The verification result displays as the following figure rr DS100 User Manual ID NU 29 ID NU 24 Name Name Verify Card Verify FP Verified Verified Step 3 If the card has not registered yet it will prompt that the card is not registered 1 4 Connection with Computer The device only records attendance time After that the data can be processed by software on computer Therefore it is necessary for the device to connect with a computer to download the attendance record or upload the user data and so on The following is the description of Ethernet connection method gt Through hub Use the net cable to connect the device and computer to the same network gt Direct connection Use the cross cable to connect the device and the computer directly Set device Enter Menu Comm Net
2. Must Save Information When you enroll the card or fingerprint card save the enrolled information in the device or not No means the information is only saved in the card Yes means the information is saved in both card and device Operation Only VF ID gt Card PHD Must Save Info nv 4 OK M Back ESC 28 1L 1 O DS100 User Manual Press A Wto move cursor to the item to be set If it is the input box press numeric keys on keyboard to input the value If it is the roll box press lt gt button to switch the values After setting press M OK directly to return to the previous interface Press ESC to cancel setting and return to the previous interface Ore Card sensor area is 3cm 5cm above fingerprint reader 29 rr DS100 User Manual 3 Communication Settings When the device and computer are used to transmit data it is necessary to use communication wire to set communication parameters in the device When the device is in communication communicating appears Don t operate the device then note When the device is communicating with computer please check the setting here The parameters here must be in accordance with that of software communication interface ree NetWork Security WiFi Setup Wirless LAN 3 1 Network Option When Ethernet is used for communication of device and computer the following settings need to be checked Device IP address IP is 192 1
3. 3 Insert U disk into USB slot of fingerprint reader enter U disk management upload data upload user photo The operation is the same with that of 6 6 upload user defined picture 4 Enter U disk management download download user photo and a folder named photo will be created automatically in U disk Downloaded user photos are all saved in this folder Eun 1 The name of user photo must not be over 8 digits 2 When user is verifying U disk must be inserted into the device all along 10 13 Backup Battery The device supports external backup batteries During removing the battery be sure to disconnect the external power supply Technical Specifications Standard three hours Discharged more than 4 Operate 20 C 45 C Relative 10 90 See may o Recommended After fully charged the battery should be stored storage condition under 20x5 C 65 20 RH Cycle Life Charged discharged cycle for more than 300 times 80 the amount of capacity 76 rr DS100 User Manual 10 14 About the Human Rights Privacy Statement Dear customer First thank you for using Multi biometric identification product we design and produce As one of the global famous fingerprint identification core technology provider we are keep carrying on the development and research also we believe such action is necessary to a comply with the law or legal process served on Our company b protect and defend the rights or property of Our c
4. ESC After IP is specified press M OK to save the setting and then return to wireless option interface After setting press M OK directly to return to the previous interface Press ESC to cancel setting and return to the previous interface 34 rr DS100 User Manual Otherwise user can use the WIFI Software in the device accessory CD ROM to set the parameters For details please refer to Appendix 10 11 WIFI Software Using Instructions 3 4 Wireless Network GPRS Check wireless signal and the signal intensity received in the current environment to create condition for user to select better network Valid Network 00 25 61 24 d5 f2 technical 00 36 24 75 e5 22 Press M OK to set the selected wireless network Press 4 to refresh the list 35 DS100 User Manual 4 System Option Set system parameters to meet user s demand as much as possible a System Data Mng Keuboard D Display eset E Misc Set 4 1 System Parameter 1 1 matching threshold value The similarity of ID fingerprint verification and the enrolled template 1 N matching threshold value The similarity of verification and the enrolled template Recommended matching threshold value Matching threshold value FRR FAR 1 N 1 1 high low 45 25 middle middle 35 15 low high 25 10 Date format Time format displayed on the initializing interface of fingerprint reader Press button to select the format
5. Enroll password Enroll user s password The effective digit is 1 8 The employee with password enroled can use password to record attendance Card Registered staff s Card only the registered card is possible to check attendance Purview Users are people whose identity must be authenticated before enter a menu The ordinary consumer can track attendance by the card or the password only the manager already may equally carry on the daily checking attendance with the ordinary consumer but may enter the menu to operate each option or When there is no administrator any person may enter the main menu and operate after the administrator is enrolled no one can enter the main menu until the administrator confirmed For example the following is the flow for Add user 1 Input ID NO User ID 1 Allocate ID NO by default 2 Press lt lt to delete the allocated ID NO by default Input ID NO from keyboard If the ID NO is wrong press lt lt and input it again 2 Input Name Scroll A V keys to locate the cursor on the input box of Name Use T9 input 13 rr DS100 User Manual method to input employee s name 3 Enroll fingerprint Scroll A V keys to locate the cursor on the Enroll FP button then press M OK to start fingerprint Enroll FP 3 0 e Quality Press Finger Press finger according to device s prompt Press the finger three times in the proper way If one fingerprint is enrolled successfully
6. Press it on the initializing interface for 3 seconds to enter power off count down state 2 Shortcut 1 Cancel the operation and return to the superior menu 2 Close T9 input 65 1L 1 O DS100 User Manual 10 2 USB Host The device will may be used as USB Host to exchange data with external U disk The data transmission speed is quick the traditional fingerprint machine only supports the RS232 RS485 or Ethernet way data transmission when as a result of physical condition limit data quantity big and the data transmission cost quite long time But the USB data transmission is more quick than the former any transmission mode may complete downloading data by U disk in a short period of time like this greatly enhances the efficiency The operational steps of the device as USB Host please refer to the manual 6 Download and Upload detailed briefing 10 3 Time Ring In many factories ringing apply to broadcast message to inform employee their duty are on or off and the traditional way is to ring bell by manual or special electron machine We have already embedded the time ring module into the fingerprint T amp A system you may benefit from the low cost and convenience management There are more two options that is Bell schedule and Bell duration in the device bell ring provide with The system total has eight Bell schedule to set according to actual need you may set time bell when the time arrive at the appointed time
7. When the cursor is on the text box you can press the shortcut to enable T9 input and input SMS content Press A V to switch option input box You can press to change setting or press numeric key to input value 1 If the selected type is individual SMS Assign button is enabling Here it is to distribute personal SMS to employee Press A V to search employee Press M OK to select the employee and SMS will be distributed to him Press ESC to save it and then exit note If exit without selecting any employee the SMS type will become Reserved 2 If the selected type is Public SMS or Reserved SMS Assign button 22 rr DS100 User Manual cannot be used After setting press menu to save it and return to SMS list 2 Edit SMS Press A V in pop up menu to select Edit and SMS can be edited The operation is the same with that of Add SMS 3 Delete SMS Press A V in the pop up menu to select Delete and the selected SMS can be deleted At the same time all information related with this record can be cleared 2 3 2 Employee Check SMS 1 Check Public SMS When the device is in standby state the main interface will display pictures and current effective common SMS content in cycle The display time interval is the same with that of picture display d When at appears on main interface of the device press shortcut defined in 4 4 Keyboard Definition to check current effective common SMS i
8. administrator password enrollment the current enrolled fingerprint and the current saved attendance record Also display the capacity of the fingerprint and attendance record as show below SysInfo e 9 2 Firmware Version Display Alg Version Firmware Ver and MAC Address of in Firmware Version for check 62 DS100 User Manual Records Device Serv Info 9 3 Device Information Display device name serial number Auth Saler Vendor and Manu Time in device information for check SysInfo e FEET e DeviceName DS100 Serial Num 2600102070018 9 4 Server Information Display Local Serv Hotline CN and Network Serv in Serv Info for check 63 1L 1 O DS100 User Manual Records Firmware Ver Device 64 DS100 User Manual 10 Appendix 10 1 Keyboard Different device has different kinds of keyboard and the function of the keyboard is different Please check the fallows Ky Fenton O Numeric 1 0 9 used to input employee number password and so on 2 0 on manage user interface is shortcut of search user 1 Upward 2 Shortcut 1 Downward 2 Shortcut 1 Modify current item value 2 Shortcut 3 Enable T9 input 4 Switch input method in T9 input 1 Modify current item value 2 Space back Press it when User ID password and system value are input incorrectly to delete the wrong value and input the value again 3 Shortcut 1 Power off
9. 11 wireless networks there is DHCP Or enter IP interface to input correct IP address subnet mask and so on Operation Network Type 4 RuthMode 4 Encryp Mode r IP Address Wor E mansa Get IP address faild ok M Back ESC Press A V to switch cursor to the input box or button Use T9 input to input network ID which must be input or the cursor cannot be moved to other input box Press P button to select the item you need to set and then press M OK to do the corresponding operation 1 Set password According to the selected authentication mode and different encrypt types the interface where password is set is also different There are two interfaces WEP and WPA WEP password PHD Index DECH 4 PHD Tupe PHD1 PHD2 PHD3 PHD4 OK M Back ESC 33 rr DS100 User Manual Input correct password There are four passwords in WEP password If the four passwords are set properly only the current selected password is the effective value WPA password HPAPHD e PHD 848 64Bit ASCII or 16Bit Hex OK M Back ESC Input correct password set password press M OK to save the setting and then return to wireless option interface 2 Specify IP Specify the device IP in wireless network It has nothing to do with network option in communication option IP adr DE do do do LL MEO No No o cateuay OE No No No OK M Back
10. After finish set press M OK directly to save the setting and return to the previous interface Press ESC to cancel the setting and return to the previous interface e g The In Position set as Left Return to the initial interface the interface shown as below Check Check in out The Left screen show as Check in and the Right screen show as Check out The shortcuts defined by user are invariable right now note In the standby state press ESC key can show the above interface 49 1L O DS100 User Manual then the staffs can check which fingerprint reader Corresponding Check In Check Out 50 Ur DS100 User Manual 5 Time Date 5 1 Time Date Option Accurate attendance time is based on accurate time date Enter Date Time to set options Operation DateTime ULM LEGO LEGGE DLST Nor B Enter DLST NEM Nr Standard BENE E E i Fel H de t6 E Sock ESC Press A V to move cursor to the input box Press numeric key on keyboard M to input the value After finish set press M OK directly to save the setting and return to the previous interface Press ESC to cancel setting and return to the previous interface 5 2 DLST DLST also called Daylight Saving Time is a system to prescribe local time in order to save energy The unified time adopted during the system date is called DLST Usually the time will be one hour forward in summer It can make people sleep early and get up early
11. It can also reduce lighting to save power In autumn the time will be recovered The regulations are different in different countries At present nearly 110 countries adopt DLST To meet the demand of DLST a special option can be customized on our RF 51 1L O DS100 User Manual Card Time amp Attendance recorder Make the time one hour forward at XX minute XX hour XX day XX month and make the time one hour backward at XX minute XX hour XX day XX month if necessary Operation DateTime 6 TIE W LEO L ULM LEO LEG E DLST Mor E Enter DLST NEM v Standard Caen ack E30 1 Set DLST as ON 2 Input DLST start time and end time For example if 08 00 April 13 is set the device enter DLST and the time will be one hour forward If it is 08 00 August 1 the device will reset normal time Time FEY FER Es Enter DLST T 08 m Standard M uc EN OO S D H M 3 Press M OK to save setting Press ESC to exit without saving 52 1L 1 O DS100 User Manual 6 Download and Upload Import user information fingerprint template attendance data and so on in the device to attendance software or import user information and fingerprint to other devices through U disk or SD card Dn Upload Kal U Disk Upload SD Download SD Upload Back ESC 6 1 Download by U disk 1 Download attendance data Save all attendance data in the device to U disk Operation 1 Insert U d
12. ad 9 for example ad 1 jpg 69 1L 1 O DS100 User Manual 3 The file name won t be changed after it is uploaded to the device If it is necessary to change this picture upload another picture with the same file name to cover it 4 Every picture cannot be over 20K or it cannot be uploaded 5 The picture s resolution is 400 wide and 240 high It is better not to be more or less than it 6 The propaganda pictures count should be 10 at most 10 7 Short Message Management Our some product provide a function which can send a message to assigned person through public to person way We only need use the back end software to set it then upload it to the fingerprint machine as long as the attendance dive start the for public short message will be seen on machine screen and it will show for ever for a person short message will not display until the user s fingerprint verification is positive Thus reduces the work load to manager the human power greatly enhances the working efficiency Send a message to a assigned personal if a staff s birthday is on October 20 we may set back end software to send out a short message to him wish your Happy Birthday on 20 October upload it in the machine after this staff the fingerprint verify successfully on that day this message will display on the screen Send a message to public if entire company needs to have a meet on June 19 after we set back end software to upload the machine upo
13. at present with the fingerprint related with user number Use this method when it is difficult to identify user s 5 rr DS100 User Manual fingerprint Step 1 Input User ID of employee to be verified on the initial interface ID ND Step 2 Press fingerprint properly on the reader Step 3 If the device says Thank you the verification is complete If you press the finger on the left FP reader it is 1 1 fingerprint verification and the verified result displays on the left side of the screen ID NO 1 Name Autumn Verify FP Verified If you press the finger on the right FP reader it is the 1 N fingerprint verification for any user to verify 1L 1 O DS100 User Manual ID NU ID NO 2 Name Summer Verify FP Verified If the device says Please try again return to step 2 for second operation Employee can try another 2 times by default The repeated times can be set in 4 5 Interface Option If it fails after 2 times return to step 1 directly 2 Password Matching Step 1 Input User ID of employee to be verified on the initial interface Then press M OK ID NU Input PHD Step 2 If it displays Error ID NO it means that there is no such number If it prompt to press finger that the employee doesn t enroll password Step3 Input password and press OK If you input the right user password it is the password verification the result will display on the left side of the screen
14. check Enter Record input corresponding information in the query condition input box Record DO RE start RR Mont boss TE End Mont Day PM Hour ENUZSN Ers 1 When the User ID is blank all employees are inquired 2 When input a User ID only this employee s attendance record can be queried After query the records in accordance with the conditions will be displayed on the screen 60 rr DS100 User Manual Record ID NO 27 RS 02 16 16 51 16 46 16 24 15 26 14 20 14 20 14 20 Details Press A V to move the cursor to the line to be queried And press M OK to check attendance record For example the detailed attendance information of employee 27 on Mayeth as follows 02 16 16 46 02 16 16 24 02 16 15 26 02 16 14 20 02 16 14 20 02 16 14 20 02 16 13 59 mm mn ODT mn mim Total Record 08 F FP Gs Break Out At the bottom of the screen there are some remark and the capital letters with their meanings Verification F Means Fingerprint verification P Means Password verification C Means ID card verification Status It is the attendance status The code displayed in the list is the status code And status name will be displayed in the information column 61 rr DS100 User Manual 9 System Information Use system information to check the current device s saving status its version information and so on 9 1 Record Capacity Display the count of enrolled users
15. harmful substance contained in all homogeneous materials of this part is in the limitation requirement stipulated in SJ T 11363 2006 X ndicate the content of the toxic and harmful substance contained in at least one homogeneous material of this part is beyond the limitation 79 rr DS100 User Manual requirement stipulated in SJ T 11363 2006 Note The 80 product has adopted the manufacture with non toxic and harmless environmental protection materials the non toxic and harmless substances or elements instead of the toxic and harmful substances or elements contained can not be achieved because of the current technology and economic constraints 80
16. out Break out Break in Overtime in OT In and Overtime out OT Out The state needs to be modified manually that is you can switch to the desired work state by pressing the corresponding button To decrease the manual operations the device menu provides a state Auto Switch option At the time specified by a user the device automatically switches the state The current state is displayed on the initial interface Backspace Function lt 4 No ii Name Auto Switch JN Sur Moo WEI uro ou WI uoo Boo ELM sat O doo 12 1L O DS100 User Manual After the user sets the state Auto Switch in a week the system checks whether the state needs to be switched by minutes When the user saves the settings the saving operation of the same day or same time does not take effect 10 11 Wi Fi Software Using Instruction WIFISetting Wireless End Active Disable Wireless Network ID Wireless Model Infrastructure Model Authentication Type OPEN Encrypt Type NONE Connection parameter TCP IP RS232 485 USBClient IP USA M aem Port Current State Disconnected ConfigM achine Step 1 Wireless End has two options Active Disable If you select the Active item you can configure the AP Access Point If you select the Disable you can set the connection way of the device and its configuration of IP address Step 2 Full the blank of local Wire
17. press M OK to continue another finger and then press ESC to return the previous interface 4 Enroll password Scroll A V keys to locate the cursor on the Enroll PWD button and press M OK to enroll password Enroll PHD Input PHD Max Length 8 digits PHD Affirm Max Length 8 digits Tome Back ESC Input password 1 8 according to the prompt and press M OK to verify it Then press M OK save it or press ESC to exit without saving it 14 rr DS100 User Manual After saving P signal will be on the device which means the password has been set 5 Enroll cards Scroll A V keys to locate the cursor on Enroll card button and press M OK to enter the card registration Enroll Card 7 Punch Card Slight ware the card near the sensor area after the equipment found the card number press M OK key to save press ESC to give up then remove the card from the equipment after the Enroll successfully the card number will display on the register button 6 Purview setting Scroll the A V key and local cursor on the Privilege option box scroll lt gt key to choose privilege 7 Save exit user registration To confirm the registration information is correct after getting confirmation save it The way for saving 1 Scroll A V key to locate cursor on the OK M button please press M OK key again the prompt Change saved Continue on the equipment press M OK the key to continue oth
18. setting and return to the previous interface Press ESC to cancel setting and return to the previous interface 4 6 Reset Make device s communication option system option and so on reset to the state of factory Reset Al Default Setting Make all the parameters in the device reset to the state of factory Reset Keyboard Setting Reset the corresponding setting of keyboard definition to that of factory Reset Bell Setting Only reset bell option to factory state Reset Other Parameters Only reset communication option system parameter and interface option and so on to factory state 44 1L O DS100 User Manual Reset Keyboard Setting Reset Bell Setting Reset Other Parameter Press A V to move cursor to the button to be operated Press M OK to start operation The device will say Are you sure Press M OK to reset it to factory state and press ESC to cancel operation woe The employee s information and attendance data won t be deleted when this operation is being done 4 7 Bell Option Many companies need bell for on duty and off duty Some use manual bell Some use electronic bell To save cost and provide convenience for management we integrate bell functions to fingerprint reader You can set time for bell When it is the scheduled time the device will play the selected ring automatically And the ring will stop automatically when it is the end time Operation 45 rr DS100 User Manual bello
19. the device will automatically ring bell the duration of ringing achieve assigned hour the ringing will stop automatically There are two to ring bell 1 Send sound from the speaker of device 2 Connect the external electrical bell to the device when arrive the appointed time the device will send signal to trigger relay 66 rr DS100 User Manual 10 4 T9 Input Method The name of T9 input method is the smart input method it is famous for highly effective and quickly inputting the character this equipment fully supports the T9 Chinese the T9 English and the symbol input There are three or four English letters on 0 9 numeric keyboards of the machine for example the numeric keyboard 1 has the A B the C three letters only input key where this letter locate for the T9 Chinese Press the algorithm of the program will automatically combine the legitimate Pinyin Then press the numeric key to choose Pinyin for inputting the Chinese character The T9 English also comply with the letter arrangement of English word to input only press key which inputs this letter the program automatically display this key expressed all letters press the numeric key to select letter The T9 input method also may input some marks May input the name the short message content through the T9 input method user is able to input the name the short message content T9 character input take Angel for example Press to enter T9 input And press Kk t
20. you need to set The fingerprint 36 1L 1 O DS100 User Manual reader supports ten date format YY MM DD YY MM DD YY MM DD MM DD YY MM DD YY MM DD YY DD MM YY DD MM YY DD MM YY and YYYYMMDD Select your desired date format Key beep Press to set whether the key has voice or not Yes means having voice and No means no voice Sensitivity Set the sensitivity of the FP sensor Voice prompt Press to select whether to give voice prompt or not The device will give corresponding voice prompt during operation Volume Press ik to set it Alg Version Only support 10 0 algorithm version Recheck Minutes It is in the set time range unit minute If somebody s attendance record has been there then the record of second attendance won t be saved effective value is 0 60 minutes O means all the records after verification are saved Log Alert After the free time period reaching this value the device will trigger alarm automatically effective value is 0 99 0 means the space is all used and there is no alarm Operation Threshold 1 1 1 N Date Fmt M vv MM DD gt keubeep Ou sensicivitu lt 4 voice rn cn lt gt KC rr inger vX10 0 E ReCheck Min o Log Rlert Bs Press A V to move cursor to the input box If it is the input box press numeric keys on keyboard to input the value If it is the roll box press lt gt 37 rr DS100 User Manual button to switch the value
21. 68 1 201 by default You can modify it if it is necessary But it cannot be the same with that of computer Subnet mask It is 255 255 255 0 by default You can modify it if it is necessary Gateway address It is 0 0 0 0 by default If the device and computer are in 30 rr DS100 User Manual different net segment it is necessary to set address DNS Server Set the DNS Server for the communication Net speed Set the speed according to the LAN where the device is Operation NetWork IP Address 192 Dech Foi Subnetmask 255 Tee Ross do GateHau o pfo fo jo DNS server o pfo fo jo Press A Wto move cursor to the item to be set If it is the input box press numeric keys on keyboard to input the value If it is the roll box press lt gt button to switch the values After setting press M OK directly to return to the previous interface Press ESC to cancel setting and return to the previous interface 3 2 Connection Option When USB is used for communication of device and computer it is necessary to set device ID Device ID 1 254 If USB is used this ID needs to be input on the software communication interface To improve the security of attendance data connection password needs to be set here Connection password must be input when computer software is to connect device to read data Connection password System password is 0 by default namely there is no password it can be set as other value After setting th
22. DS100 User Manual Version 2 0 Firmware Version 6 4 1 build 52 Date Feb 2012 Introduction This document mainly introduces the windows and operations of DS100 dual FP reader device rr DS100 User Manual About this manual Not all the devices have the function with The real product prevails 9 The photograph in this manual may be different from that of the real product The real product prevails 1L 1 O DS100 User Manual Contents 1 Operating Instruction cere e eee eene eee eee eee eeneseeeeeeeess T 1 1 Abbreviated Operating Drocedures l 1 2 How 16 Press the Fingerprint eode odes otianteneanncecrauncdaiiesretauisnedaiaeseetuess P Ee ee ANC eresse ae 3 1 3 1 Select Attendance State 0 0 ceesccsssecssteessseeessesesseesenes 3 1 3 2 Identity VerifICallOl E 4 1 4 Connection with COmpUtef u eoe errtp peer geg een sas dove de Eb Va aaa Pke e deen 9 Fo Man eege 10 PE ET EE 12 2 ser Nana CIE AK ena a cue etn cu aedis a oreet esu Ed 16 AA Seah USET c 17 2 2 2 Query Attendance Hecornd 17 EE 18 EAS Delete 19 ed Add USO 20 E EE 20 PAR ef ps e ho cr 21 2 3 2 Employee Check SMS eese eene renes 23 24 Card Management 9 erint i Phan bero bes etri hene nnda 25 PS NES M 25 2 4 2 Clear Card Information 0 c ccccccscccccsssceccesssseeceessseeeeeesaee
23. Only some models have card options User ID cannot be modified The operation is similar to that of add user Fingerprint can be re enrolled Click enroll password directly to set password or modify password The access can also be modified Save edition exit edition 1 Press menu or A Y to select OK M lt press M OK save edition and return to user management interface 2 Press ESC or A V to select ESC and then press M OK and the device will prompt Do you want to save changes If you want to save it press M OK and return to the previous interface Or press ESC to return the previous interface directly 2 2 4 Delete User Del user is to delete employee s partial information or all information from the device It is used when the following states happen 1 When fingerprint or password of the employee is not needed any more 2 When employee leaves the position Press A V on user management interface or use search user to select the employee to be edited Click menu to get operating menu and then select 19 rr DS100 User Manual Del User Delete user Del User 6 ID NO 27 P Delete Fingerprint Back ESC om Only some models have Del ID Card Only options If the user has no fingerprint or password the corresponding item is blue and cannot be operated Press A V to select the item to be operated Press M OK to pop out dialog box and verify whether to delete this item or not Then the de
24. S Upload SMS in SD card to the device Operation Insert SD card into SD card slot of the device Press A V button to select upload SMS and then press M OK Udata dat and sms dat will be uploaded to the device 3 Upload photo Upload user photo in SD card to the device Operation Insert SD card into SD card slot of the device Press A V button to select upload Photo and then press M OK The user photo named as userlD jpg will be uploaded to the device 4 Upload user defined picture Upload JPG picture started with ad in SD card to the device Then this picture will be displayed on the initializing interface Refer to Appendix 10 6 Propaganda Picture Upload Rules Operation Insert SD card into SD card slot of device Press A V to preview the pictures of SD card If you want to upload the picture click M OK Then the next picture will appear automatically After upload press ESC to exit 57 1L 1 O DS100 User Manual 7 Auto Test The device can test various modules automatically to help operator to judge the module with fault quickly Auto test include TFT Test Audio Test Keyboard Test Sensor Test and RTC Test Auto Test Keuboard Test RTC Test Audio Test TFT Test Press A V to select the item Press M OK to start it 7 1 TFT Test The device can automatically test TFT color display effect through color display white display and black display to see whether the screen works n
25. anged by minutes 4 4 2 Use Shortcut 1 Status key Press key on standby interface and the corresponding status will appear at the left bottom 42 rr DS100 User Manual 2 Shortcut key e g Set 0 as view SMS in setting Press 0 on standby interface to enter the interface of SMS Smile 4 5 Interface Option 1 1 Match Retry Times amp Password Retry Times When user is using 1 1 match or password verification he may forget to enroll fingerprint or does not press the finger in the proper way For user s convenience and to reduce repeat key the device allows retry User can set initializing interface s display style Clock Mode After verification the selected clock mode will be displayed on the screen Picture Delay means how soon the picture will be changed effective value 43 DS100 User Manual is 3 999 seconds Clock Delay means the clock picture display time length after verification After the display delay the propaganda picture will be displayed on the initializing interface again with effective value of 0 999 seconds and O means displaying clock all along Operation Display Setup e 1 1 Match RetryTimes Range 1 9 Password RetryTimes Range 1 9 ClockMode gt 1 fi SN D TET IW PictureDelay D ClockDelay so E Press A V to move cursor to the input box Press numeric key on keyboard to input the value After finish set press M OK directly to save the
26. e Attendance Management and stat them at the end of the month 1L 1 O DS100 User Manual 1 2 How to Press the Fingerprint Enroll fingerprint by pressing index finger middle finger or ring finger thumb and little finger are clumsy 1 Proper press Make finger center pressed on the sensor window 2 Improper press Upright Too lean Too downward i Please adopt the correct way to place the finger to avoid improper operation led to the identification performance degradation em o ww em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em mm e rr DS100 User Manual 1 3 About Attendance When the device is in standby status only after successful fingerprint or password verification can user save attendance record on the device Standby status is as shown below The picture displayed in standby status can be uploaded by user please refer to 6 Download and Upload It can also be time display refer to 4 5 Interface Option 1 3 1 Select Attendance State Mode 1 When the device is in standby status press state key on the device to modify attendance state and the state information will be displayed on the screen The current selected state is displayed in orange Refer to 4 4 Keyboard Definition for default state key definition DS100 User Manual Mode 2 Variou
27. e password must be input if software is to communicate with device Or the connection will fail 31 rr DS100 User Manual The password length is 1 6 digits Operation Security DevicelD 1 254 Password ODE Max 6 digit ES Peack ESC Press A V to move cursor to the input box Press numeric key on keyboard to input the value After setting press M OK directly to return to the previous interface Press ESC to cancel setting and return to the previous interface 3 3 Wireless Option WIFI Before the device is used for wireless network other physical groupware of 802 11 networks such as joint distributing system wireless medium must be in existence ESSID to connect to the network must be known network ID Network ID Network ID to be connected to wireless network There is difference between small letter and capital letter Network model there are two models infrastructure model for star structure and ad hoc model for peer to peer network Authentication mode Infrastructure mode includes five authentication modes OPEN SHARED WEPAUTO WPAPSK and WPA2PSOO2E Ad hoc model Include four authentication modes OPEN SHARED WEPAUTO and WPANONE Encrypt type when the selected encrypt type is NONE the password in WEP Wired equivalent privacy and WPA Wi Fi protested access cannot be edited namely it is not necessary to input password 32 rr DS100 User Manual Device IP address In 802
28. eried Press M OK after successful query the blue cursor will point to the employee If there is no such employee no enrolled data will appear 2 2 2 Query Attendance Record When administrator is checking employee s fingerprint and other enrolled information he can also check the employee s attendance record during that month Press M OK on user management interface to get the operating menu select Record and the employee s monthly attendance record can be checked 17 rr DS100 User Manual Record ID NO 27 3 53 15 26 Details D The picture may be different from your device The real product prevails Press A V to read attendance record Press M OK for detailed information 02 16 14 20 02 16 14 20 02 16 14 20 02 16 13 59 Total Record 05 FsFP S O0t In Then press ESC to return to user management interface 2 2 3 Edit User Edit user information saved in the device For example the former enrolled fingerprints are unusable enter edit user to re enroll fingerprint password or card Use A V or search user on user management interface to select employee to be edited Then press menu to select Edit or press shortcut to 18 1L 1 O DS100 User Manual verify it and all enrolled information can be displayed on the device s M ID NO 2 LEM ae Enroll FFP FP Num 1 ZONE Enroll PAD BI Croll Card purview lt EE gt oeo Back ESC note
29. erwise press ESC to exit 2 Press the ESC key or scroll A V key to locate the cursor on the Back ESC button please press M OK key again the prompt Do you want to 15 1L 1 O DS100 User Manual save changes appear on equipment press M OK key to save and return to the previous interface does not save and return to the previous interface press ESC key 2 2 User Management All users information saved in the current device can be queried in User Management including user name fingerprint count whether to enroll password or card user attendance record and so on Editing or deleting user can also be done here m D e 3 4 a 6 7 S uote Fh 1 E Means this employee is the administrator PF Means password has been enrolled gt Means ID card has been enrolled 2 The picture may be different from your device The real product prevails Press M OK on the above interface and the operating menu will pop out b Search User S E Q9 q eu Del User Ze a Neu user D Press A V to select the item 16 rr DS100 User Manual 2 2 1 Search User If many users are enrolled in order to find an employee quickly the device has provided User ID to search the employee Press menu on manage user interface to get operating menu Select Search user or press any numeric key to enter the following page Search User 62 Ke Tome Back ESC M Input ID NO of employee to be qu
30. ess any key or finger to awake it FP Image Select whether to display the fingerprint image on the screen when it is enrolling or verifying there are 4 options display upon both enrollment and verification only display upon enrollment only display upon verification not display upon enrollment and verification Power Button To prevent hostile power off select whether to lock power off 47 DS100 User Manual or not Key Position Choose the display position of the keyboard input Key on the left side PWD H Input PHD Key on the right side ID NU PHD 7 i d H Input PHD in amp Out User defined whether start Check In Check Out split screen function The default state is N When you set it as Y then the set item of In Position will pop up shown as below 48 rr DS100 User Manual Misc Set e sleep time M O 4lways On Both Shou 4 ENG gt Left 4 ly D Left FP Image Power Button Key Position In 0ut Karen Back ESC In Position Press to select as Left or Right the default value is Left D don Language ENG dto d left In Position namely all the successful verification at the left fingerprint reader s attendance state is Check In all the successful verification at the right fingerprint reader s attendance state is Check Out vice versa Press numeric key on keyboard to input the value to be set
31. false accusation or false incrimination directed against citizens by any means is prohibited the protection of freedom of the person and the residence The Constitution provides for the freedom and privacy of correspondence of the citizen Finally we hereby stressed that once again as one kind of advanced identification technology the fingerprint identification will apply to electronic commerce bank insurance law service industry in the future every year all world cause from the lack of security password the humanity are suffering the heavy loss In under high safe and secure environment the fingerprint identification protect your status from damage in fact 78 DS100 User Manual 10 15 Environmental Protection The environmental protection use period marked on our products is the safety period of our products used under the conditions specified by this manual without toxic and harmful substances leaking happened The environmental protection use period marked on our products does not include the easy wear and tear components required to be replaced regularly such as the battery etc The battery s environmental protection use period is 5 years The toxic and harmful substances or element names and the content table The toxic and harmful substances or elements Part name SMD resistor SMD capacitor SMD inductance SMD diode ESD components Buzzer Adapter Screw O Indicate that the content of the toxic and
32. i wav bell01 bel Lol bellO1 bellol bell01 bello1 bell01 Setting Press A V to read bell option Press M OK to set the selected bell and edit the bell Time The bell rings automatically when it is the specified time Music Bell ring Volume ring volume Times Ring times State Whether to enable this bell Period Bell time can be set with week as the period namely the bell rings automatically at some time of some day in a week Press A V keys to move the cursor locate on the week and then press M OK to select After select week locate the cursor on the OK M button and then press M OK key to save e g Set the bell time as 08 30 and select the Period as TUE Then at 08 30 of Tuesday the device will automatic bell show as below 46 1L 1 O DS100 User Manual ie BS pss Ted Be Ba Time os P M Music 4 Volume 4 State m oy d Press A V to move cursor to the input box Press numeric key on keyboard Times to input the value After finish set press M OK directly to save the setting and return to the previous interface Press ESC to exit 4 8 Other Options Set sleep time external bell and other parameters for the device Sleep time M O Always On FP Image Power Button ON 4 Language 4 Key Position 4 In amp Dut d Mee 4 Back ESC Sleep Time When it is the scheduled sleep time the device not in operation will enter sleep status Pr
33. is downloading attendance data until it is successfully downloaded 3 Press ESC to return to initializing interface Pull out SD card X attlog dat attendance log will be saved in SD card X stands for device ID 2 Download User Save all users information and fingerprint in the device to SD card Operation Insert SD card into SD card slot of the device press A V to download user then user dat user information and template dat fingerprint template will be saved in SD card 3 Download SMS Save SMS added to the device to SD card Operation Insert SD card into SD card slot of the device Press A V button to select download SMS After successful download udata dat and sms dat can be seen in SD card 4 Download Photo Save user photo in the device to SD card Operation Insert SD card into SD card slot of the device Press A V button to select download Photo After successful download the user photo will can be seen in SD card as the format of userlD jpg 6 4 Upload by SD Card 1 Upload user data Upload user information and fingerprint saved in SD card to device 56 rr DS100 User Manual Operation Insert SD card into SD card slot of fingerprint reader Press A V to select upload user data and then press M OK and user dat user information and template dat fingerprint template in SD card will be uploaded to the device If there are no such files data copy error will appear 2 Upload SM
34. isk into USB slot of the device 2 Press A V to Download Attlog Press M OK for verification Downloading wait will appear on the display when the device is downloading attendance data until it is successfully downloaded 3 Press ESC to return to initializing interface Pull out U disk X attlog dat attendance log will be saved in U disk X stands for device ID 2 Download User Save all users information and fingerprint in the device to U disk 53 rr DS100 User Manual Operation Insert USB flash disk into USB slot of the device press A V to download user then user dat user information and template dat fingerprint template will be saved in U disk 3 Download SMS Save SMS added in the device to U disk Operation Insert U disk into USB slot of the device Press A V button to select download SMS After successful download udata dat and sms dat can be seen in U disk 4 Download Photo Save user photo in the device to U disk Operation Insert U disk into USB slot of the device Press A V button to select download Photo After successful download the user photo will can be seen in U disk as the format of userlD jpg 6 2 Upload by U disk 1 Upload User Upload user information and fingerprint saved in U disk to device Operation Insert U disk into USB slot of the device Press A V to select upload user data and then press M OK and user dat user information and template dat finger
35. less Network D you want to connect with this 73 rr DS100 User Manual blanket must be fulfilled C2 uote Must fulfill the blank that is marked with Step 3 Wireless Model there are two options Infrastructure Model and Ad hoc Model click the drop down box to select the wireless network model depending on the different topology of network The Infrastructure Model will apply to Hub and Spoke wireless network it include five Authentication Type that are OPEN SHARED WEPAUTO WPAPSK WPA2PS The Ad hoc Model is used in the peer to peer wireless network It includes OPEN SHARED WEPAUTO and WPANONE four type of Authentication Type Step 4 Click the drop down box to select the Authentication Type Step 5 Click drop down box to select Encrypt Type When the item NONE of encrypt Type is selected then the password in WEP Wired equivalent privacy and WPA Wi Fi protested access item is not permitted to modify it itis not need to input password too Step 6 According to Authentication Type and Encrypt Type to input the password password complies with the criterion set down by the software note there are four group passwords in the WEP column till the all password have been set up is correct the current password is valid Set Connection Parameter The device fully support two connection ways one TCP IP anther one is RS 232 74 1L 1 O DS100 User Manual If you select TCP IP here the IP a
36. n this day the message holds XX meet in XX room will continuously display on the screen asks everybody certainly such information you are allowed to revise according to your need to XX participation Short message function setting After setting Short message in the Time amp Attendance software then upload it to fingerprint machine the fingerprint machine support two kind of way to import the short message which the 70 1L O DS100 User Manual software connect with fingerprint machine to import it directly other way by U flash disk Operation Step as follow 1 Through Time amp Attendance software external program gt short message management complete to set short message then connect with the fingerprint machine and upload it 2 Through Time amp Attendance software external program short message management complete to set short message choose external program gt U flash disk manage gt export short message gt export to U disk after exporting successfully plug the U disk into the fingerprint machine press M OK key enter the main menu of the machine gt Dn Upload gt Upload short message Short message function effect For public short message will be seen and it will show for ever after this staff the fingerprint verify successfully this message will display on the screen OM There is total 1024 items of public for personal short message 10 8 Mifare Card In order to meet sec
37. n time 23 1L O DS100 User Manual Nice to meet uou 2 Check Personal SMS When user passes verification if the user has SMS the SMS content will be displayed SMS Happy_birthday The information display time length is 30 seconds During this period user verification can be done Close the current display to enter verification interface 24 rr DS100 User Manual 2 4 Card Management Support Mifare non touch intelligent card with working frequency of 13 56 MHZ Integrate fingerprint attendance to other systems and support multi verification mode to meet the demands of different people Operation Enroll FP Card Erase Card Info Copy Card Info Card Setting Back ESC Press A V to select your desired item press M OK to execute the current selected item 2 4 1 Enroll Card Use Mifare card as ID card Only card number is needed to enroll Operation 1 Enrollment Step 1 Select Enroll ID Card and then press M OK 23 1L 1 O DS100 User Manual Enroll ID Card e Step 2 Press keyboard to input the number to be enrolled if the number has been there already the device will prompt you to copy the information to the card and then press M OK Enroll ID Card e 1 Punch Card Step 3 The device prompts to punch card Step 4 Put the card in the sensor area until the operation is successful 2 Verification Punch the card in the sensor area After the device read
38. nd Port value must to be assigned its value is same with one in the communication option of the device Set the option Ethernet in the device to Yes If you selectRS232 must configure these parameter Device ID COM Port Baud rate same with one in the communication option of the device Configure the wireless Network IP address 1 Click ConfigMachine button the following menu pops up ConfigMachine DHCP Config IP Address 2 Select Config IP Address option after input IP Address click the Subnet Mask input box and the Subnet Mask will automatically display according to IP Address 3 Click OK button save setting and exit this interface After all setting for wireless network is completed single click SET button on the MODEMConfigTool interface the prompt in working will appear on the device After configure successfully the corresponding message will inform you click OK to close the message and restart the machine so the configuration change take effect 10 12 Photo ID Function Some devices support Photo ID function which can display user photo saved 15 1L O DS100 User Manual in U disk or SD card on the screen as well as User ID name and so on after verification Operating Step 1 Create a folder named photo in U disk and store user s photo in it 2 The photo format must be JPG and file name must be User ID For example the name of photo of user whose User ID is 154 must be 154 jpg
39. need such upgrade file please contact our technician Usually firmware upgrade is not recommended Operation Insert U disk with upgrade file into the USB slot The device will identify the file automatically The device will give prompt whether it is successful or not 4 4 Keyboard Definition User defined the device s attendance status key Press corresponding status key to record attendance Press any status key on the standby interface and the attendance status and status key will be displayed at the left bottom of the screen Operation 39 rr DS100 User Manual Function Now Name Status Key 0 Check In Status Check Out Status Break Out Status Break In status t In status Ot Out view SMS Press A V to read shortcut definition Press M OK to edit the selected shortcut 4 4 1 Set Shortcut 1 Set it as function key E g Set 0 key as View SMS Operation 1 Scroll A W keys to locate the cursor on the bar of 0 key and then press M OK key to enter the following interface 1 2 1 5S BEA der ine 2 Press the 9 key to select the Function as View SMS show as below 40 rr DS100 User Manual Function lt View SMS gt M oouo Back ESC 3 Press M OK key to save and then return to the previous interface 2 Set it as status key Select Backspace key as example Scroll A V keys to locate the cursor on the bar of Backspace key and then press M OK key to ente
40. o shift input method of Pinyin English and Symbol and then select English Neu user ID N Name EP Enroll FFP FP Num o Input 2 to get the first ZEE Enroll PHD letter and press 3 to A Card Enroll Card Purview lt 4 English ng c TEES HA Be Se OK MZ Press M OK 67 rr DS100 User Manual ID NO Name iii Use the same method to EP FP Num input the other letters PHD ngel Card Purvieu 4 Press ESC to exit 68 rr DS100 User Manual 10 5 Quick Query of Attendance Record It is used for common user to query his intraday attendance record to see whether there is something wrong for attendance time and notify administrator the abnormal recorder in time Operation Press M OK to display the employee s intraday records after successful fingerprint or password verification in 10 minutes For example the employee with User ID of 1 can check his intraday attendance record by pressing M OK after fingerprint verification Record ID N0 27 Se 02 16 16 51 16 46 16 24 15 26 14 20 14 20 14 20 Details SEN The picture may be different from your device The real product prevails Press A V to read attendance record Press M OK to query detailed information Press ESC to return to initial interface 10 6 Propaganda Picture Upload Rules 1 The picture format must be JPG Other formats are not accepted here 2 The file name of propaganda picture must be ad O
41. ompany including the enforcement of our agreements or c be governed by related law or legal that involve to the human rights and the privacy in each country We are committed to protecting your privacy We state as follows 1 Our civil fingerprints identification equipment merely captures fingerprint features point but not the fingerprint image does not involve and retain privacy 2 he fingerprint features points are not to be recovered the primitive fingerprint image will not involve the privacy 3 We took an equipment provider in no event shall we are liable for any direct or the indirect against legal behavior arising out of use or inability use our equipment 4 If you have the different dispute for close the human rights or the privacy arising out of using our equipment please directly contacts with your employer Our other the police fingerprint equipment or the development kit provide with the function that ability to capture citizen s fingerprint primitive image as for whether will constitute the right infringement to you please contact with the local government or the equipment final provider as the equipment original producer we have not any legal liability for any damage it Cause TI 1L 1 O DS100 User Manual Dm There are limited rights to privacy and human rights in the Chinese Constitution The personal dignity of citizens of the People s Republic of China is inviolable and further that insult libel
42. or SD card the user info and attendance data etc can be imported to the accordingly software to deal or import the user information for other fingerprint devices to use 10 rr DS100 User Manual Auto Test Automatically test the function of each module if it is workable including the screen reader voice keyboard and clock Record For query the record saved in the device query record function is provided Sys Info To check the current device s saving status its version information and so on 11 1L 1 O DS100 User Manual 2 User Management The user s basic information on the device includes fingerprint password and card In company s attendance management for employee s change the information on the device also needs modification Therefore operations including Add Delete Edit and so on can be done on the device N ew U ser M ana g e 2 1 Add a New User Firstly enroll employee s fingerprint or password in the device Enter New user interface Neu user ID NO Ee oe SS FP FP Num 0 PHD Enroll PWD lame Croll Card en EN EAZ Back ESC 12 rr DS100 User Manual on Only some models have card enrollment option ID NO Staff s attendance number Name Input user s name with T9 input method FP Fingerprint Enroll employee s fingerprint Ten fingerprints can be enrolled at most The employee with fingerprint enroled can use fingerprint to record attendance PWD
43. ormally Press M OK to continue and press ESC to exit 7 2 Audio Test The device can automatically test voice prompt effect through playing voice files in the device to see whether the files are complete and the voice effect are good or not Press M OK to continue and press ESC to exit 58 1L 1 O DS100 User Manual 7 3 Keyboard Test The device can automatically test various keyboards to see whether the keys work normally or not Press any keyboard on the test interface except for M OK and ESC to check whether the pressed keyboard is in accordance with that displayed on the screen B wii appear when it is the right key and wm will appear when it is not the right key Press ESC to exit 7 4 Sensor Test The device will automatically test the FP reader to see whether it works normally Press fingerprint to see whether the image is clear and usable Press fingerprint on the reader window and the fingerprint image will appear on the screen Sensor Test D Press ESC to exit 7 5 RTC Real time Clock Test The device can automatically test the clock to see whether it works normally Press M OK to start time and then press M OK to stop time Press ESC to exit 59 rr DS100 User Manual 8 Query Record Employee s attendance records will be saved in the device For convenience query record function is provided According to user s input query condition the record will be displayed on the screen for user to
44. print template in U disk will be uploaded to the device If there are no such files data copy error will appear 2 Upload SMS Upload SMS in U disk to the device Operation Insert U disk into USB slot of the device Press A V button to select 54 rr DS100 User Manual upload SMS and then press OK Udata dat and sms dat will be uploaded to the device 3 Upload photo x Upload user photo in U disk to the device Operation Insert U disk into USB slot of the device Press A V button to select upload Photo and then press M OK The user photo named as userlD jpg will be uploaded to the device 4 Upload user defined picture Upload JPG picture started with ad in U disk to the device Then this picture will be displayed on the initializing interface Refer to Appendix 10 6 Propaganda Picture Upload Rules Operation Browse P rr Bure 222 ad 1 jpg Back ESC Insert U disk into USB slot of device Press A V to preview the pictures of U disk If you want to upload the picture click M OK Then the next picture will appear automatically After upload press ESC to exit 6 3 Download to SD Card 1 Download Attlog Save all attendance data in the device to SD card Operation 55 rr DS100 User Manual 1 Insert SD card into SD card slot of the device 2 Press A V to Download Attlog Press M OK for verification Downloading wait will appear on the display when the device
45. r the following interface Function lt 4 No m Name Auto Switch r E Function Set shortcut function for his key including status key and view SMS The following options will appear after the status key is selected No Allocate a No for status key to provide convenience to check the record statistics Name The name of key status Auto Switch When it reaches the set time point the device will switch the attendance status automatically The specific operation of set Auto Switch is described as follows 4 rr DS100 User Manual 1 Press A V keys to locate the cursor on the Auto Switch item and then press to select as On or OFF If select as On then open the auto switch function For detail please see 10 10 State Auto Switch The interface showed as below Backspace Function lt 4 No ma Name Auto Switch ON Eoo Noo Soo foo o doo o joo THU oA oc sat a 2 Press A V to move cursor to the input box Press numeric key on keyboard to input the time After finish set press M OK directly to save the setting and return to the previous interface Press ESC to cancel setting and return to the previous interface Then the device will auto change the attendance state at the time you set The current attendance state is displayed on the initial interface om After the user sets the attendance states Auto Switch in a week the system checks whether the attendance state needs to be ch
46. red in besoin IO Ee eege leede 65 REN le E 66 PO MS HII ERR rcm 66 e T9 Mos E e E 67 10 5 Quick Query of Attendance Record 69 10 6 Propaganda Picture Upload Rules cccccccccccceeeessssssseseseeeeeeeeeeeeeees 69 10 7 Short Message Mausen Eed enero ne rhe Pro peto beta pde 70 IOUS Mi te Cid NOT ann idn 71 AR E OG a in E E E E E 72 I0 TO State Auto Swill giereg aiae EERE ISA E AEREE ERE 12 10 11 Wi Fi Software Using Instruction 73 1012 Photo IDT incio Noera E R 75 Eege 76 10 14 About the Human Rights Privacy Statement 71 10 15 Environmental Prove CH Oth sssiicccssieccecenssiaedeassacccanasaspeecsttenndaleaivewdaeedectes 79 MI 1L 1 O DS100 User Manual 1 Operating Instruction 1 1 Abbreviated Operating Procedures Step 1 Install the device and power it up Step 2 Enroll users by registering his her fingerprints passwords or card Assign users security privileges directly on the device Step 3 After enrolling users verify that his her enrolled fingerprint passwords or card is valid Step 4 Configure the device communication settings Then download the users newly enrolled information from the device onto the Attendance Management Software on the computer Data can be transmitted via TCP IP or by using a USB flash drive or a SD memory card Step 5 Verify the device displays the correct day and time Then start to attendance Step 6 Download attendance records to th
47. s After setting press M OK directly to save the setting and then return to the previous interface Press ESC to cancel setting and return to the previous interface 4 2 Data Management Data Mng PCEM e NUN ear Purvieu Delete Picture Delete Attlog Delete all attendance records Delete All Delete all enrolled employees information fingerprint and attendance record Clear Purview Change all administrators into common users Delete Picture Delete all user uploaded pictures in the device Operation Press A V to move cursor to the selected button Press M OK to start operation The device will remind you whether to continue the current operation or not Then press M OK to delete all the data which won t be recovered after deletion Press ESC to return to the previous interface Delete Picture Clear the propaganda pictures uploaded to the device from U disk or SD card Refer to 6 Download and Upload for how to upload the propaganda pictures Operation 38 rr DS100 User Manual Curr 1 7 Next Prev ad O Jjpg Press A V to preview the propaganda pictures in the device Click M OK to delete all these pictures After deletion the next picture will appear Click Delete all to delete all the propaganda pictures in the device Then press ESC to return to Data Management interface 4 3 Upgrade Firmware Update the firmware by utilizing the USB Pen Drive flash drive due If you
48. s 26 2 4 3 Copy Card Intormaton 27 2 4 4 Card Geng 28 3 Communication Settings e ecce eere eere ee eee eee esses es AU SML n Ted ODIO RN E T 30 3 2 Comme hon OPHION EE 31 rr DS100 User Manual 3 9 Wireless Option WIET Y ecen er txt Paese e epe vie qa en aep REP dE eege 32 3 4 Wireless Network GPRS W woo cccesssssecccecccccssssseeeeseessesesesesesesseess 35 4 System OOO EES J d Mise Ste Ml E IMS cT m 36 4 2 Data Manage ment eege 38 2 3 Uparade Et E 39 4 4 Keyboard RE E e T 39 AA EE el e RTT 40 AAD Ueleger ee 42 2 3 Ile EIC OPON ie iei turo rie oebiixtas Det pei bun m eddxvs aE 43 Ee 44 2 7 BEP CODE E 45 Eege 47 Rule OL S I Tie Date OP WO E 51 Oe DL E 51 0 2 Upload Dy SD afd rs ceeiasecn cus sece gts avn coutcachotiaenataiceciaen a 56 T AUIO CS ET FAN EN ME E E ee ee ee eee ee 58 SEET MK 58 FREE SCIHMES MET A 50 TA ES VIS MEI E 59 7 5 RTC Real time Clock Test eeeeseeeeen nnn 59 8 Query Record EEN OO H System Information eere ee eeee eee eee eee ee eene ee eeeeeeeeeeees OD II rr DS100 User Manual LAM Record C mae eeen EE TET 62 92 Firmware e en EE TE ep PEOR e ippasd 62 9 3 Device Information eorr etii oca rd etie d Y sb ePi gra Y bea si ab v ER od re bead Ya pu 63 9A server Information easier enia epua ei dpa darte qa repetita pco sa poda d dprad 63 TU ADDODOPDGu aedi baia brin b
49. s states can be set by user Only the corresponding states come out on the left bottom corner 1 3 2 Identity Verification After successful user verification the device will return to the initial interface For dual FP reader device the attendance result displays on either side of screen left or right side of screen with the same size The keyboard input displays on any side of the screen according to the user s requirements And the fingerprint PIN and card verification displays on the same side with keyboard input the following demonstration is using the left side of screen to display Two of the FP reader can be used by the same time 1 Fingerprint Matching 1 1 N fingerprint matching Verify the fingerprint pressed on the reader at present with all fingerprint data in the fingerprint reader Two of the FP reader can be used by the same time And the attendance result will displays on left screen Step 1 Press fingerprint properly on the reader Step 2 If the device says Thank you the verification is complete gt Use the left FP reader rr DS100 User Manual ID NO 1 Name Autumn Ve p i f LU F P verified gt Use the right FP reader ID NOU 1 Name Autumn Verify FP Verified Both FP reader in used ID NO 1 ID NO 2 Name Autumn Name Summer Verifu FP Verify FP Verified Verified 2 1 1 fingerprint match User ID fingerprint Verify the fingerprint pressed on the reader
50. s the card move the card away When the verification is successful the device will give prompt 2 4 2 Clear Card Information Delete all the information in the card being operated at present Operation 26 rr DS100 User Manual Erase Card Info e 1 Punch Card Select Erase Card Info and press M OK Put the card in the sensor area waiting for device to delete all the information in the card If the card data has been stored in the device the device will remind you whether to delete the information in the device or not Yes is to delete the user s fingerprint and information in the device No is to keep the information 2 4 3 Copy Card Information Copy card information to the device after that the fingerprint is still in the card then press fingerprint attendance directly on the device with no need of using card Operation Copy Card Info e User Info 88 FP Select Copy Card Info and press M OK Press A V to select copy User Info or User Info amp amp FP and then press M OK 27 1L 1 10 DS100 User Manual Copy Card Info e 1 Punch Card 2 4 4 Card Setting Set password of Mifare card and decide whether the information should be saved or not Only Verify ID Verify the user as ID card verification Fingerprint Card Password After the password is set the device will write password into the enrolled fingerprint card Then the fingerprint card can only be used on this device
51. urity market need our fingerprint biometric verification reader can be embedded EM and Mifare reader module Using 125MHZ 13 56 MHz non contact smart card technology these fingerprint products provide users with new options for supporting multi authentication of identity Combine a non contact card presentation with a fingerprint biometric Or use a personal identification number PIN number along with a non contact card presentation See multi authentication The fingerprint products provide three levels of fingerprint verification During the enrollment process the LCD prompt will guide the user to place their finger on the reader The fingerprint template is collected at the unit and 71 1L 1 O DS100 User Manual immediately transferred to the card During this enrollment process the fingerprint template is stored on the card or the fingerprint machine During verification at the door the LCD graphical display will assist the user with instructions about finger placement on the biometric reader For more detail see EM Mifare Card user Guide 10 9 9 Digit Code When go on enrolling user in the fingerprint machine along with the standard enrolling code is five digit its range is 1 65534 if you need that the enrolling code is longer in the actual application we can provide a customized design that the fingerprint machine own nine digit code 10 10 State Auto Switch The system supports six work states Check in Check
52. vice will give corresponding prompt Press ESC to return to user management interface 2 2 5 Add User In order to add user conveniently for operator Add user is configured here The function is the same as that in 2 1 Add a New User 2 3 SMS The operator can edit the SMS content in advance and make it displayed on the screen SMS includes common SMS and individual SMS If a common SMS is set the SMS figure will be displayed in information column at the bottom of standby interface in specified time You can press the shortcut can be set in 4 4 Keyboard Definition to check the SMS content If individual SMS is set the employee who can receive SMS can see SMS after 20 Ur DS100 User Manual successful attendance Operation Happy Birthday Or The picture may be different from your device The real product prevails Press A V to read SMS Press M OK to pop up SMS setting menu dg New S Edit i Delete 2 3 1 Set SMS 1 Add SMS Press A V in pop up menu select New to add a new SMS Start The time when SMS comes into effect Valid Effective time length SMS appears in the effective time After the effective time it won t appear Information Type Personal SMS aimed at individual only Public SMS able to be seen by all employees Reserved Preset SMS no difference of individual SMS or common SMS 21 rr DS100 User Manual Operation start Wa A Mo 17 A Valid FO pe REEE By
53. work to set the following items IP address Default IP as 192 168 1 201 You can modify it if it is necessary Subnet mask Default subnet mask as 255 255 255 0 You can modify it if it is necessary Gateway Default gateway address0 0 0 0 You can modify it if it is necessary NetSpeed There are three options ATUO 10M and 100M rr DS100 User Manual Password Connection password It can be set or not set If it is set input corresponding numerical value on connection interface of computer software 1 5 Main Menu Start at the device and long press the M OK key to open the Main Menu as shown in the following figure User Mng Comm System Dn Upload Auto Test Record User Management Browse the users basic information like ID name fingerprint card password and privilege and so on Increase edit or delete operation the basic information and the card management Comm Communication Set up communication parameters between the equipment and the computer including IP address Gateway Subnet mask Net Speed DevicelD device number Password communications password etc System Manage the data and set the system parameters including basic parameters interface parameters fingerprint and attendance parameters to maximize meet user s needs in the functional display and other areas Date Time Device time date should set accurate to ensure the accurate attendance time Dn Upload By USB flash disk