1. mail siare it Web http www siare it MorpheusE_TFT_te_rev4 doc 10 10
2. mixtures that include nitrous oxide N20 IN CASE OF LACK OR LOW OXYGEN PRESSURE CUT OFF Audible alarm with immediate cut off of nitrous oxide delivery AGAINST HIGH PRESSURE IN SUPPLY Safety valve calibrated at 0 8 bar for the protection of the glass rotameters IN CASE OF LACK OR LOW COMPRESSED AIR PRESSURE All the devices supplied with compressed air are automatically supplied by oxygen except the flowmeter AGAINST THE CONTEMPORANEOUS DELIVERY OF AIR AND N20 Selecting valve on the front panel Device to deviate fresh gas addressing them to the anaesthesia unit valves group or to a TO and FRO patient circuit for manual ventilation By push button on the front panel Max flow 35 l min e No 3 sockets for distribution system O2 N20 ARIA e No 2 sockets for cylinder O2 N20 e No 2 sockets for Oo e No 1 socket for AIR e No 1 fresh gas connector for external use for ex TO and FRO selectable by lever on front panel e Socket for recycle of exhaust monitor gas e Connection for anesthetic gas scavenging optional device 300A or 200P 4 10 BREATHING SYSTEM General description LUNG VENTILATOR ee Fixing Type of Ventilation Control modality Dead space compensation system Flow generation MorpheusE_TFT_te_rev4 doc siae Compact system with automatic connections easy dismountable and autoclavable It allows the ventilation in modality real open circuit s
3. vaporizers No 3 outlets SCHUKO 220 Vac max 10 A 12Vdc 20Watt Oxygen therapy group Jar group for Venturi tracheal aspiration 73 x 73 x 136 L x D x H cm without monitor 100 kg without accessories Temperature from 10 to 40 C Relative humidity from 10 to 90 non condensing ELECTRONIC GAS MIXING DEVICE General description MorpheusE_TFT_te_rev4 doc It has the function to regulate the capacity and the concentration of gas mixture Air O gt N20 showing it on electronic displays as well as to deliver it to the anesthetic gas vaporizer It allows to select the mixture to be delivered Air O2 or N2O O2 and the O2 enrichment to the delivered mixture in emergency situations It includes a device which guarantees a minimum concentration of 25 oxygen in all gas erogating conditions MIX LIFE device Through the three pressure gauges on the front panel it allows the continuous control of medical gas feeding pressure coming from the gas pipelines system The flowmeter box is electronically controlled and has a traditional type safety flowmeter indicating the total capacity 2 10 Autotest Oxygen rotameter Nitrous oxide rotameter Air rotameter Medical gas supply Control gauges Power supply Battery Alarms MorpheusE_TFT_te_rev4 doc siere At the start up the equipment checks the acoustic indicator and displays integrity Moreover eventual gas leakage in the device secondary circuit are
4. verified and in case the relevant alarm occurs The test duration is of approx 15 seconds and it is not interruptible Scale 0 1 15 l min Resolution 0 1 l min Accuracy 7 of displayed value Scale 0 1 9 l min Resolution 0 1 I min Accuracy 7 of displayed value Scale 0 1 15 l min Resolution 0 1 l min Accuracy 7 of displayed value OXYGEN Gas pressure included between 280 kPa and 600 kPa 2 8 6 bar Max required flow 90 l min NITROUS OXYDE Gas pressure included between 280 kPa and 600 kPa 2 8 6 bar Max required flow 15 l min MEDICAL COMPRESSED AIR Gas pressure included between 280 kPa and 600 kPa 2 8 6 bar Max required flow 90 l min No 3 on the front panel O2 N20 ARIA scale 0 10 bar 220Vac 50Hz or 110Vac 60Hz 12Vdc 1 2Ah Pb battery which guarantees around 1 hour operation e Oxygen pressure failure or low pressure with consequent block of nitrous oxide delivery e Nitrous oxide pressure failure or low pressure e Air pressure failure or low pressure e 02 Concentration lower than 20 e Power failure e Low battery power e Gas leakage 3 10 Safety devices Deviator with double outlet Oz emergency By Pass IN gas socket on gas supply group OUT gas socket on gas supply group Other MorpheusE_TFT_te_rev4 doc siae AGAINST THE ADMINISTRATION OF HYPOXIC MIXTURES MIX LIFE Guarantees a minimum concentration of 25 oxygen on
5. AS Dimensions and weight 37 x 27 x 25 mm lt 30 g cable not included General specifications MorpheusE_TFT_te_rev4 doc See on relative Multigas Analyzer Modules technical data sheet 8 10 siere POWER SUPPLY Electric power supply 220 Vac 50 60 Hz 110 Vac optional Power 50 W Internal power supply 12Vdc battery 3 Ah Internal battery operation Max 1 5 hours Re charging time Around 10 hours CONFORMITY TO NORMS Class and type according to IEC 601 1 Class 1 Type B Class according to EEC 93 42 Directive Class IIB EN 1281 1 IEC 601 1 IEC 601 1 2 ISO 5369 BS 4272 Part 3 Dir va 93 42 EEC IEC 601 1 4 UNI EN 740 ACCESSORIES Supplied accessories User s Manual O gt supply hose N20 supply hose AIR supply hose Oo supply hose for cylinder N20 supply hose for cylinder O cell Oz cell cable Supporting arm for patient circuit Jar for Venturi aspirator Yellow Diss connector e Silicone patient circuit for adults Mapleson C patient circuit for adults e KIT for manual ventilations Scavenging hose Power supply cable Optional accessories See on Export Price List MorpheusE_TFT_te_rev4 doc 9 10 siere SIARE applies the UNI EN ISO 13485 2004 and EEC 93 42 Directive Quality System SIARE ENGINEERING INTERNATIONAL GROUP s r l Via Pastore 18 40056 Crespellano Bologna ITALY Tel 39 051 969802 Fax 39 051 969366 Email
6. MORPHEUS E Workstation for gaseous anaesthesia code OM9001 rev 4 dd 01 09 2009 DESTINATION OF USE sieve The MORPHEUS is a workstation for gaseous anaesthesia and it can be used on adults children and newborns patients The MORPHEUS is suitable for administration of Oxygen Air Nitrous Oxyde Halothane Enfluorane Isoflurane Sevoflurane Desflurane Halocarbon 22 mixtures GENERAL DESCRIPTION The unit for anaesthesia MORPHEUS is completed with MorpheusE_TFT_te_rev4 doc electronic gas mixing device O2 N20 AIR lung ventilator heated closed open valves group w 2 5 Kg CO2 absorber double interlock selectatec support for 2 vaporizers gas supply group breathing monitoring system 1 10 GENERALITIES Structure Wheels Work shelf Shelves Drawer Cylinder support Vaporizer connection Auxiliary power supply outlets Work shelf lighting lamp Other Dimensions Weight Environmental Conditions siere Light aluminium alloy varnished steel and plastic moulds N 4 Diameter 100 mm The two front ones with pedal brakes Dimensions 37 x 35 78 L x D H cm Dimensions 61 x 36 L x D cm Max loading capacity 30 Kg No 2 inner dimensions 38 x 34 x 14 L x D x H cm No 2 vertical cylinder supports on back side for cylinders up to 7 It capacity and round rubber pads Double vaporizer connection Selectatec type with system which avoid the contemporary opening of the 2
7. emi closed circuit closed circuit at low flows The system also allows the spontaneous and manual ventilation also in case of machine breakdown or machine off The CO absorber canister has a rapid connection and this allows its replacement also during operation The recycling system is a selective type hence the soda lime and fresh gases consumption is reduced to the minimum Reservoir bag orientable support to facilitate the manual ventilation The circuit is heated to reduce condensation and heat the fresh gases The switching from one modality to another is completely controlled by ventilator without any user s action on valves group All group internal connections are stainless steel made The group is completely autoclavable and does not have disposable parts On the upper part of the trolley by a quick connection device to the main structure IPPV Electronic by microprocessor The equipment is equipped with an electronic system which at every start up and for a few seconds verifies all the hardware and software electronic parts for safety purposes Os cell automatic calibration leakages test and compliance calculation are on operator request only Automatic Digital System 5 10 Gas feeding Ventilation Modes Breathing rate I E Ratio Inspiratory Pause SIMV Frequency Tidal Volume Minute Volume PEEP Inspiratory Flow Oxymeter Bronchomanometer Trigger sensibility Safety User s Inte
8. lume Flow Trend Trend scale and period setting Trends Pmax Pmean Ppause PEEP VTi VTe ExpMV Rate FLOWi MorpheusE_TFT_te_rev4 doc 7 10 siere Help Display of the user s manual optional Monitor Setting of the following displaying conditions LCD Remote 1 LCD Remote 0 Zoom parameters page displaying Zoom Parameter Page Displayed parameters PEEP Flow Insp Minute Vol 1 E Pmax Flow Exp Tidal Volume Rate Displayed curves Paw Flow Volume Gas type configuration and selection optional e Measure gas Stop gas Set agent Set zero Set O2 Set Gas alarm Set CO2 unit e CO O2 N20 AG Alarm volume Can be set from 1 to 3 Demo option Available Language option Available Flow sensor Automatic setting of OFF SET and GAIN parameters Connection 9 poles male connector RS 232 Remote monitor MULTI GAS optional Multigas analyzer modules connection Available Description Ultra small infrared main stream multi gas probe comprising a multi channel IR bench barometric pressure sensor power regulator signal processor and a RS 232 interface Measuring mode Mainstream Model A57 049 301 CO2 O2 N20 HAL ENF ISO SEV DES with Manual identification of halogenated GAS A57 049 601 CO2 N20 HAL ENF ISO SEV DES Agent ID with Automatic identification of halogenated G
9. o make future equipment updates easier The TFT Monitor can be connected to multigas analyzer modules Functioning and control Operator interface Microprocessor electronic every time the equipment is switched on a check lasting a few seconds is carried out of all the hardware and software of the system for safety purposes Keyboard controls function selection ESC return alarm silencing and Encoder knob Display area Parameters measured Messages Graphs Zoom Area 2 zone Functioning modes Parameters measured Pmax Pmean Pause PEEP Vti Vte ExpMV Rate FLOWi FLOWe L E Tinsp Tesp Tpause Cs Ri Messages Operating mode Interruptions Functioning time Alarm Graphs available Ventilation graphs Loop Trend Help Parameter Zoom page Zoom Area 2 areas for the selection of the ventilation parameters Functioning Modes Zoom Area 2 zones Zoom Area 2 zones Alarms setting default Loop Trend Help Monitor Alarm volume Demo display Gas type configuration and selection Possibility of selecting and displaying any parameter measured Alarms Manual or automatic setting of the alarm minimum and maximum limits Buzzer volume adjustment and visual alarm flashing symbol in the message area indication Alarms Pmax Pmean Ppause PEEP VTi VTe Expmv Rate Cs Ri Ventilation curves Paw Flow Volume Loop Volume Paw Vo
10. rface Alarms Flow sensor MorpheusE_TFT_te_rev4 doc siere Medical Compressed Air or Oxygen with pressure included between 280 kPa and 600 kPa 2 8 6 bar AUT IPPV AST PCV PSV SPONT SIMV APNOEA BACK UP MANUAL performed via breathing system or via manual external system for example TO and FRO From 5 to 140 bpm 1 1 1 2 1 3 1 4 2 1 3 1 From 0 to 50 of the inspired time From 0 to 139 From 20 to 1500 ml From 1 to 30 liters 0 20 cm H20 From 0 to 100 lit min Built in with display of O2 concentration Min resolution 1 Automatic calibration procedure Electronic with led bar and display from 10 to 80 cmH20O Electronically adjustable in continuous way from 1 to 9 cmH20 under PEEP level Airways pressure electronic and mechanic limit Self diagnosis system LED Display Back enlightened LCD Display LED bar Broncomanometer Other LED indicators Control keys and knobs LOW HIGH O HIGH LOW AIRWAYS PRESSURE APNOEA POWER SUPPLY LOW BATTERY GAS SUPPLY HIGH LOW MINUTE VOLUME HIGH LOW TIDAL VOLUME HIGH LOW RATE By magnetic perturbance reusable st rilisable 6 10 siere TFT 6 5 colour respiratory monitor Description The TFT Monitor can display the respiratory parameters and the curves and loops clearly providing immediate information on the patient s ventilation The user interface and the alarm and patient monitoring functions are designed t