1. 1 ON OFF MENU EXIT o G GO BACK TO THE PREVIOUS MENU PRESS TO ACCESS THE MENU TURN TO SELECT ACCESS MODIFY PRESS TO MEMORISE ENGLISH MENU TEXT VALUE FUNCTION SET TEMPERATURE SET H20 65 80 C Selection of the boiler temperature set point of SET POWER POWER 01 05 Selecting the power Activation deactivation ENABLE CHRONO ON OFF SET ADJUSTMENTS weekly programmer PELLETS 30 20 Selecting the percentage of pellet feed STATUS 1 AND 2 References reserved to the technician of DAY MON SUN Setting the day of the week HOURS 00 24 Adjustment of the hour SET MINUTES 00 59 Adjustment of the minutes CLOCK DATE 1 31 Adjustment of the date MONTH 1 12 Adjustment of the month YEAR 00 99 Adjustment of the year ENABLE CHRONO OFF Activation deactivation of the weekly programmer START PRG1 OFF 00 00 1 ignition time STOP PRG1 00 00 1 switch off time MONDAY PRG1 OFF yA SUNDAY PRG1 ON OFF Ignition switch off consents for various days SET PRG1 65 80 C Temperature setting for the 13 time span START PRG2 00 10 OFF 00 00 2 ignition time STOP PRG2 00 10 OFF 00 00 Time 214 switch off time MONDAY PRG2 OFF f a USER MENU SUNDAY PRG2 OFF ON OFF Ignition switch off consents for various days CHRONO SET PRG2 65 80 C Setting room temperature
2. hourly fuel consumption kg h 2 0 Tank volume 121 Recommended flue draught mbar 0 1 Nominal electric output W 470 Nominal voltage Vac 230 Nominal frequency Hz 50 Water inlet outlet pipe diameter 1 Automatic exhaust pipe diameter 1 2 Pump head m 5 Max working water pressure accepted bar 2 5 Min working water pressure accepted bar 0 6 Flue gas temperature 69 8 105 9 Flue gas flow rate g s 7075153 Boiler class 3 Combustion period h 4 12 Water thermostat field of regulation C 65 80 Water return minimum temperature AG 55 Dimensions of the feeding door mm 576 Lx 236P Yield 92 0 nioworwaren WATERS gi mbar AT 10K 2751 6 148 Corresponding temperature difference AT 20K 1375 8 74 QExtraflame ENGLISH INTRODUCTION The boilers produced in our establishment are built with attention to the individual components so as to protect both the user and the installer from any accidents It is therefore recommended that after any intervention on the product that authorised staff pay particular attention to the electric connections especially the stripped parts of the wires These must not escape from the terminal board in any situation thus preventing possible contact with the live parts of the wire The instruction manual is an integral part of the product make sure that it always accompanies the appliance even if transferred to other owners or user or is transferred to another place If it is damaged or lost reques
3. EXTRAFLAME S p A cannot be held responsible for the failure to comply with such precautions WARNING THE WARRANTY IS VALIDATED ON THE CONDITION THAT The installation and relative connections of the plant have been carried out by professionally authorised staff in total compliance with the Standard in force M D n 37 dated 22 January 2008 in compliance with the Standards in force both national and regional as well as these instructions Testing has been carried out by a qualified technician who assumes the entire responsibility to have verified that the plant has been realised in compliance with the Standard in force by professionally qualified staff in compliance with the Standards in force and to have checked the good functioning of the installed product Once this has been verified the after sales centre will supply all the information for its correct use filling in and delivering a copy of the document which certifies the warranty undersigned by the client EXTRAFLAME S p A assures that all its products are manufactured with top quality materials and with manufacturing techniques which guarantee total efficiency If during normal use of the product defective or badly working particulars should be detected the replacement of such particulars will be free of charge ex dealer who made the sale TERRITORIAL EXTENSION OF THE WARRANTY Italian territory VALIDITY THE WARRANTY IS CONSIDERED VALID ON THE CONDITION THAT 1 The purch
4. WILL LIGHT UP ON THE TO ENABLE THE CHRONO FOLLOW THE INSTRUCTIONS AS DESCRIBED IN THE ENABLE CHRONO m CONTROL PANEL QExtraflame ENGLISH SCREEN ENTRY AND EXPLANATION CONTROLS PROCEDURE Turn P2 to select the icon SET CHRONO Press P2 to confirm m Tur P2 to select SET CHRONO ars Confirm pressing P2 MONDAY PRG1 d Turn P2 to select the desired parameter gt Press P2 to enter modification mode Turn P2 to modify the value Press P2 to confirm and exit Ifyou wish to exit without memorising press key P1 ate RASO _ STOP PRG1 First time slot switch off time MONDAY gt Day allowed or not on off TUESDAY PRG1 gt Day allowed or not on off WEDNESDAY PRG1 Day allowed or not on off THURSDAY PRG1 Day allowed or not on off _ FRIDAY PRG1 gt Day allowed or not on off SATURDAY PRG1 gt Day allowed or not on off SUNDAY PRG1 gt Day allowed or not on off _ SETPRGI gt Setting water t ADJUSTING LANGUAGE see chapter commissioning settings DISPLAY Activating OFF the back light of the display will go off after a preset delay The back light will go on as soon as a key is pressed or if an alarm should be triggered in the machine CONTROLS PROCEDURE gt e DISPLAY Turn P2 to select the icon Press P2 to confirm Turn 2 to select DISPLAY Confirm pressing P2 Tur
5. for the 2 time slot START PRG3 00 10 OFF 00 00 3 ignition time STOP PRG3 00 10 OFF 00 00 3 switch off time PRG3 OFF SUNDAY PRG3 ON OFF Ignition switch off consents for various days SET PRG3 65 80 C Setting room temperature for the 3 time slot START PRG4 00 10 00 00 4 ignition time STOP PRG4 00 10 OFF 00 00 45 switch off time en PRGA OFF SUNDAY PRG3 ON OFF Ignition switch off consents for various days SET PRG4 65 80 C Setting room temperature for the 4 time slot LANGUAGE ITAL ENGL DEUT FRAN ESPA Selecting the language DISPLAY DISPLAY OFF ON Delayed switch off of the backlighting RESET RESET ON OFF Resets the values modifiable by the user back to the default values QExtraflame ENGLISH SET TEMPERATURE The following menu allows the boiler temperature to be set The possible settings are 65 80 C CONTROLS PROCEDURE SET H20 From the main screen turn P2 to select the SET TEMPERATURE icon Press P2 to confirm Turn P2 to adjust the TEMPERATURE Confirm and memorising by pressing P2 To exit without memorising press key P1 94 9 96 SET POWER The following menu allows to set the power Minimum power 1 maximum power 5 CONTROLS PROCEDURE From the main screen turn P2 to selectthe SET TEMPERATURE icon Press P2 to confirm Turn P2 to adjust the POWER Confirm and memorising by pressing P2 To exit without memorising press key P1
6. of more valves heading a single pipe The discharge piping of the safety valve must be realised in order not to prevent the regular functioning of the valves and not to cause damages to persons the discharge must flow immediately near the safety valve and be accessible and visible The diameter of the discharge piping must not however be lower than that of the outlet connection of the safety valve For diameter of outlet connection it is intended the minimum internal diameter on the valve outlet upstream of the eventual internal threading CLOSED EXPANSION VESSEL Warnings check that the preload of the expansion vessel is set to 1 5 bar The vessel maximum exercise pressure must not be lower than the calibration pressure of the safety valve increased by overpressures characteristic of the same valve bearing in mind the eventual level difference between vessel and valve and the pressure generated by the functioning of the pump The capacity of the expansion vessel s is evaluated depending on the total system capacity as results from the project The closed expansion vessels must comply with the dispositions regarding the planning manufacturing evaluation of conformity and use for pressure appliances Intercepting objects or section decreases must be inserted practiced on the connection piping which can be constituted by system portions The insertion of a three way intercepting valve which allows connection between the vessel and the atmosphere for
7. operation has been performed the appliance automatically enters the switch off phase blocking the supply of pellets The flue gas exhaust motor will remain on until the stove temperature has dropped below the factory parameters RE IGNITION The stove can only be re ignited automatically or manually when the cooling cycle conditions and the preset timer have been satisfied NO IGNITION FIRST IGNITION COULD EVEN FAIL AS THE AUGER IS EMPTY AND IS NOT ALWAYS ABLE TO LOAD THE BURN POT WITH THE REQUIRED AMOUNT OF PELLETS ON TIME TO REGULARLY START THE FLAME ori WAIT FOR THE MACHINE TO COOL DOWN GREEN SCREEN PRESS KEY 1 FOR3 SECONDS IF THE PROBLEM OCCURS AFTER ONLY A FEW MONTHS WORKING CHECK THAT ROUTINE CLEANING STATED IN THE STOVE BOOKLET HAS BEEN CARRIED OUT CORRECTLY Extraflame ENGLISH ADDITIONAL THERMOSTAT There is a possibility to thermostat a room adjacent to the room where the stove is positioned just connect a thermostat following the procedure described in the next step it is recommended to position the optional mechanical thermostat at a height of 1 50 m from the floor The default STBY function is always active it cannot be disabled and the STBY clamp is jumpered contact closed ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY ACTIVE When the contact or external thermostat is not satisfied open contact temperature reached the stove will switch off As soon as the contact or external thermostat switch
8. pellet in the event of insufficient depression in the relevant models REFERENCE STANDARDS The installation must be in compliance with UNI 10683 2012 heat generators fed with wood and other solid fuels installation The chimneys must be in compliance with UNI 13063 1 and UNI EN 13063 2 UNI 1457 UNI EN 1806 in the event of non metallic chimneys EN 13384 1 13384 chimneys Thermal and fluid dynamic calculation methods UNI EN 1443 2005 chimneys general requirements UNI EN 1457 2012 chimneys clay ceramic flue liners UNI TS 11278 2008 Metal chimneys flue liners flue ducts UNI 7129 point 4 3 3 Fire Brigade provisions local rules and regulations NATIONAL REGIONAL PROVINCIAL AND TOWN COUNCIL REGULATIONS One must also bear in mind all laws and national regional provincial and town council Standards present in the country in which the appliance has been installed ENGLISH TERMS AND DEFINITIONS Aeration Air renewal is required both for the disposal of the combustion products and to prevent mixtures with a hazardous content of non combusted gases Closed hearth appliance Appliance designed for operation with closed combustion chamber Forced draught appliance Appliance with ventilation in the fumes circuit and combustion with fumes flow at a positive pressure with respect to the environment Chimney Structure consisting in one or several walls containing one
9. product 4 Presence of electric and or hydraulic plants that do not comply with the standards in force 5 Damages deriving from atmospheric chemical electro chemical agents improper use of the product modifications and tampering with the product inefficacy and or unsuitability of the flue and or other causes not deriving from the manufacture of the product 6 Combustion of materials not compliant with the types and quantities indicated in the manual book supplied 7 All damages caused by transport It is therefore recommended to carefully check the goods on receipt immediately informing the dealer of any damage making a note on the transport document and on the carrier s copy EXTRAFLAME S p A is not liable for any damage that can directly or indirectly affect persons objects and pets as a consequence Extraflame ENGLISH of failure to comply with the prescriptions indicated in this manual book ALL PARTICULARS SUBJECT TO NORMAL WEAR ARE NOT COVERED BY WARRANTY This category includes gaskets all ceramic or toughened glass coverings and cast iron or Ironker grids the painted chrome or gold plated details the majolica the handles and the electric cables o Colour variations crackles and slight size differences f the majolica parts are not a reason for claims as they are natural features of the materials themselves e Parts in refractory material 9 Masonry work The system particulars for the produ
10. relative to lack of routine maintenance contact the technical after sales centre THESE BOILERS MUST BE USED TO HEAT WATER TO A TEMPERATURE THAT DOES NOT EXCEED BOILING POINT IN THE CONDITIONS OF INSTALLATION RECOMMENDED DISTANCES FOR THE BOILER COMPARTMENT Below are a few images relative to the minimum distances required in the boiler room The company recommends the following measurements to be complied with REFERENCES NON INFLAMMABLE OBJECTS REFERENCES NON INFLAMMABLE OBJECTS A 500 mm D 300 mm B 1 000 mm E gt 80 cm 1 000mm Extraflame ENGLISH WARNINGS The instruction manual is an integral part of the product make sure that it always accompanies the appliance even if transferred to another owner or user or if transferred to another place If it is damaged or lost reguest another copy from the area technician This product must be intended for the use it has been specifically made for The manufacturer is exempt from any liability contractual and extracontractual for injury damage caused to persons animals and objects due to installation adjustment and maintenance errors and improper use Installation must be performed by qualified staff which assumes complete responsibility for the definitive installation and consequent good functioning of the product installed It is necessary to bear in mind all laws and national regional provincial and
11. to contact the after sales technical service to carry out at least the following operations Set the master switch to position 0 Close the water taps of both the heating system and the domestic hot water system Empty the heating system and the domestic hot water system if there is risk of freezing COMMISSIONING After removing the packaging ensure that the content is intact and complete Otherwise contact the dealer where the appliance was purchased from When commissioning the product verify that all safety and control devices that the boiler consists of work well All electrical components that make up the boiler must be replaced with original spare parts exclusively by an authorised technical assistance centre thereby guaranteeing correct operation Before leaving the system the staff in charge of commissioning must monitor boiler operation for at least one complete work cycle The boiler must be serviced at least once a year programming it in advance with the technical assistance centre APPROVALS The Extraflame boilers have been designed and realised in compliance with the following Directives UNI EN 303 5 Boilers for central heating Boilers for solid fuel with manual and automatic feeding with a nominal heat output of up to 300 kW 9 Compliance with the Low Voltage Directive 73 23 EEC Compliance with the EMC Directive Electromagnetic compatibility 89 336 EEC FOR SAFETY It is forbidden for the boiler to be us
12. town council Standards present in the country the appliance has been installed Extraflame S p A cannot be held responsible for the failure to comply with such precautions After removing the packaging ensure that the content is intact and complete Otherwise contact the dealer where the appliance was purchased from All electric components that make up the product must be replaced with original spare parts exclusively by an authorised after sales centre thus guaranteeing correct functioning SAFETY Thestove must not be used by persons including children with reduced physical sensorial and mental capacities or who are unskilled unless they are supervised and trained regarding use of the appliance by a person responsible for their safety Children must be monitored to ensure they do not play with the appliance Do not touch the stove when you are barefoot or when parts of the body are wet or humid The safety and adjustment devices must not be modified without the authorisation or indications of the manufacturer Do not pull disconnect twist electric cables leaving the stove even if disconnected from the electric power supply mains It is recommended to position the power supply cable in a way that it does not come into contact with hot parts of the appliance The power supply plug must be accessible after installation Do not close or reduce the dimensions of the airing vents in the place of installation The airing vents are in
13. 9 9 96 SET ADJUSTMENTS The set user menu offers the following possibilities automatic manual mode allows enabling disabling the chrono inside the boiler pellet adjustment allows pellet adjustment ENABLE CHRONO The boiler chrono can be enables disables from this menu CONTROLS PROCEDURE ENABLE CHRONO From the main screen turn P2 to select the SET ADJUSTMENTS icon Press P2 to confirm O N Turn P2 to take CHRONO ENABLING to ON Confirm and memorising by pressing P2 LI To exit without memorising press key P1 9 9 96 Extraflame ENGLISH PELLET ADJUSTMENT The following menu allows to adjust the percentage of pellet feed If the stove has functioning problems owing to the guantity of pellets adjust pellet feeding directly from the control board The problems correlated to the amount of fuel can be divided into 2 categories NO FUEL the stove can never develop a suitable flame tending to remain very low even at high powers at minimum power the stove tends to almost switch off taking the stove into NO PELLETS alarm condition when the stove displays the NO PELLETS alarm there may be non burned pellets inside the burn pot EXCESS FUEL 9 the stove develops a very high flame even at low power the panoramic glass is very dirty obscuring it almost totally the burn pot tends to become encrusted blocking the holes for air intake due to the excessive pellet feed as
14. AGE nee Sal Eigen a Ba o ameli 26 OPERATION AND LOGIC sercsrcrrrrrrrererere see nie nazio nese ne see nese nananana enene nese ne see ninneeio nese nese e nina ne senese arene nese ne senese a nine nese nesee nie neeienesenene 27 ADDITIONAL THERMOSTAT ssrrrererereseeriee nese 2 2 e nize nese nenee nine nese 2 2 e ninanesa nanne neze nese eene nese 2 nie 6 28 ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY ACTIVE ssesssssssssssessssssssseesssssessssessssesssseessssesssseesssesssnssssssesssesssuesssesssusessusesssnsessanessans 28 ADDITIONAL THERMOSTAT INSTALLATION nese neneneso MENU STRUCTURE ersersnsesnssnsennennsensennsensennsnnsennennsensennsonsennsensennsnnssnnennsensennsensennsnnsennennsensennsensennsnnsennennsensennsensennsnnsennennsenssnnsenee SET TEMPERATURE SET POWER SET ADJUSTMENTS QEXtraflame ENGLISH TECHNICAL FEATURES FEATURES LP 30 Weight kg 333 Height mm 1406 Width mm 875 Depth mm 772 Flue exhaust pipe diameter mm 120 Air intake pipe diameter mm 60 Max global heat output kW 33 8 Max useful thermal power to the water kw 31 1 Minimum global heat output kw 10 Min useful heat output kw 8 6 Max hourly fuel consumption kg h 7 0 Min
15. CTION KIT STOVE POSITIONING ccnl RA SAFETY DEVICES A REFERENCE STANDARDS 22u 200r00020000000020000000n000000n0n00000000000000000000000000 GENERAL nr IN SAATI O NN enem nece FERENTINO eee a DE ERLERE EEE sense na E E FUMESIEX HAU SHRSIV STTIEM turesatentosccncvonctuateattaecescaccncsonstQateerteatenhonecncconctuateattnateercaccnesenccncceascncccecen R O ano GENERAL RESUIEFIVIENINE RR MM ene SMOKE DUCT COMBUSTION PRODUCTS OUTLET QUOTA FUMES EXHAUST SYSTEM PRODUCT REQUIREMENTS TECHNICAL INSTALLATION DOCUMENTATION PEBREMS AN D EEEBING CENERE occcoccencttanteeesaeanensetetettaccsncrcecccoccccscnsecsuteantunensstauananentsateaateccenAantatenantvecoscccrsoccetnantenanante Extraflame CONTROL BOARD rsstrerererecereerene nese ne see nio ne nio nese ne nee nina nasa nesnenene nese nananana n nene nera nesne nine nese ne sane nee nine nasa nese anice nese ne senese enenenesenese DISPLAY ICONS KEY GENERAL MENU poss BASICINSTRUGTIONS Luu iii 25 55 5 26 ADJUSTING TIME DAY MONTH AND YEAR sisssssessonssecssssnssssessessnssssssassecassbenvovesssesssoosstsseenscostsoessonsstavbsetnsedbatesrbssssnaveenansctosteanassstbnseacsnssebssoavssietdesoesonsstioe 26 ADJUSTING LANGU
16. ECTION TO THE CHIMNEY Protection from rain and wind Protection from rain and wind sa Steel plate a si gt airtight TA y 7 O X Q Max 3 mt la e i aN a 3 5 Insulated T fitting with T fitting with inspection plug T fitting with inspection plug inspection plug It is mandatory to use airtight pipes CHIMNEY In addition to the general requirements the chimneys for releasing combustion products into the atmosphere must operate under negative pressure operation under positive pressure is not allowed havea preferably circular internal section square or rectangular sections must have rounded corners with a radius of no less than 20 mm hydraulically equivalent sections may be used as long as the ratio between the longer side and the shorter side of the rectangle which circumscribes the section is in any case no greater than 1 5 9 be designed for fumes be designed for fumes expulsion be predominantly vertical and have no narrowing along their entire length have no more than two direction changes with a slope angle no greater than 45 be fitted with in the event of operating in damp conditions a device for reflux drainage condensat
17. N is the default setting CONTROLS PROCEDURE Turn P2 to select the icon LANGUAGE Press P2 to confirm Turn P2 to select LANGUAGE V Confirm pressing P2 ENGLISH Turn P2 to select the desired parameter Press P2 to enter modification mode Turn P2 to modify the value Press P2 to confirm and exit If you wish to exit without memorising press key P1 0 0 o BURN a IT IS PROHIBITED TO USE THE APPLIANCE WITHOUT THE BURN POT CONE SEE FIGURE TO THE SIDE INTHE CASE OF WEAR OR DETERIORATION REQUEST gt AFTER SALES ASSISTANCE FOR REPLACEMENT OF THE PART REPLACEMENT THAT IS NOT UNDER GUARANTEE AS THE COMPONENT IS SUBJECT TO WEAR CLEAN CHECKUP 1 2 S BURN POT BOTTOM SHOULD THE CLEAN CHECK UP ALARM BE TRIGGERED MAKE SURE THAT THE BOTTOM OF THE BURN POT IS FREE OF RESIDUES OR SCALES THE HOLES AT THE BOTTOM MUST BE COMPLETELY FREE TO GUARANTEE CORRECT E COMBUSTION SEE CHAPTER CLEANING CARRIED OUT BY THE USER ONE CAN USE THE FUNCTION PELLET FEED ADJUSTMENT TO ADJUST COMBUSTION ACCORDING TO THE DESCRIBED REQUIREMENTS IF THE ALARM PERSISTS AND THE ABOVE LISTED CONDITIONS HAVE BEEN CHECKED CONTACT THE QUALIFIED AFTER SALES ASSISTANCE CENTRE QExtraflame ENGLISH OPERATION AND LOGIC IGNITION Once the points listed previously have been checked press key 1 for three seconds to ignite the stove 15 minutes are available for the ignition phase After ignition and having reac
18. R MATERIAL DAMAGES THE i gt FUNCTIONS OF YOUR STOVE AND CAN VOID THE WARRANTY AND THE ANNEXED RESPONSIBILITY OF THE MANUFACTURER Extraflame ENGLISH CONTROL BOARD SABATO DAY DATE TIME REAL POWER BOILER H20 TEMPERATURE SET POWER ON OFF BUTTON KEY TO GO BACK TO THE ENCODER WHEEL PREVIOUS MENU BY TURNING AND OR PRESSING IT ONE ACCESSES THE MENUS SET SET SET SET SET SET TEMPERATURE POWER ADJUSTMENTS STATUS USER INSTALLER DISPLAY ICONS KEY It indicates weekly programming operation mt a _ Hand indicator weekly programming disabled d Chrono indicator weekly programming active Indicates the contact of the external additional thermostat It indicates pump operation 24 Closed contact the contact of the external additional thermostat Off pump deactivated STBY is closed On pump active Sg Flashing the safety device is active H20 temperature gt 85 C STBY Open contact the contact of the external additional thermostat is open Extraflame has an optional additional board that allows the boiler the following further functions when managing the system The table below indicates the various possibilities that the optional can offer DHW Storage Management id Puffer Management 3 heating areas Instant DHW option Puffer pump or 4th heating area management Anti legionella management for DHW storage DHW s
19. SE 2 WORK PHASE The door is not closed correctly The ash drawer is not closed correctly The combustion chamber is dirty The flue exhaust pipe is blocked Check hermetic door closure Check hermetic closure of the ash drawer Check cleanliness of the fumes pipe of the sensor in the primary air channel and the combustion chamber Check for the presence of pellets in the feed box NO The pellet feed box is empty Adjust pellet flow see Pellet feed adjustment IGNITION elle ice calibration inadequate Check the procedures described in the Ignition chapter NO IGNITION hm Take the stove to OFF conditions using key 1 and repeat BLACK OUT 9 9 i the procedure described in the Ignition chapter NO PELLETS M R Check for the presence of pellets in the feed box The motor reducer does not feed pellets Adjust the pellet flow see Pellet feed adjustment The door is not closed correctly Check hermetic door closure DEPR ALARM The ash drawer is not closed correctly Check hermetic closure of the ash drawer The combustion chamber is dirty Check cleanliness of the fumes pipe and the combustion The flue exhaust pipe is blocked chamber DEBIMETER Flow sensor faulty A OR centre FAULT Sensor disconnected The water in the stove has exceeded 95 C Possible air in the system H20 OVERTEMP Lack of adequate circulation Contact after sales centre Lack of or inadequ
20. accessible from inside the appliance ADDITIONAL REQUIREMENTS FOR APPLIANCES FITTED WITH AN ELECTRIC FAN FOR FUMES EXPULSION For the heat generator appliances equipped with electric fan for expelling fumes the instructions below must be followed The horizontal sections must have a minimum upward slope of 3 The length of the horizontal section must be minimal and in any case no longer than 3 metres 9 The number of direction changes including the one due to the use of the T element must not be more than 4 EXAMPLES OF CORRECT CONNECTION TO THE CHIMNEY Installation with internal external Installation with internal flue flue Protection from Protection from rain and wind rain and wind Insulated flue Insulated flue Insulated condensation proof T fitting with inspection plug Condensation proof T fitting with inspection plug PIT IT IS NOT RECOMMENDED TO INSTALL A 90 BEND AS THE FIRST INITIAL PART SINCE THE ASH WOULD BLOCK THE PASSAGE OF THE FUMES IN A SHORT TIME CAUSING PROBLEMS TO THE STOVE DRAUGHT SEE FIGURES BELOW Ash deposited in the 90 bend Ash deposited in the 90 bend QExtraflame ENGLISH EXAMPLES CORRECT CONN
21. addition to that of the 4 thermo product that can be managed with the integrated expansion vessel An additional expansion vessel must be installed for a higher content of water Head m The diagram at the side illustrates the behaviour of the pump used on our thermo products at the speeds that can be set 0 0 0 0 5 1 0 1 5 2 0 2 5 Flow rate m h OExtraflame SAFETY DEVICES SAFETY DEVICES NOT PRESENT STOVES KEY PRESEN Circuit board it intervenes directly sending the product into alarm conditions until it has fully cooled down in the event of fumes motor breakage pellet feed motor breakage black out if above 10 seconds failed ignition Door micro switch With the door open the operation of the burn pot cleaning system is blocked Electronic pressure switch in the event of inadequate 2 depression it sends the machine in alarm conditions F 2 5 A 250 V fuse stoves protects the machine from violent current surges 85 C calibrated mechanical bulb with manual rearm intervenes by blocking fuel feed whenever the pellet tank t reaches the limit of 85 C Rearm must be performed i by qualified staff and or the manufacturer s technical after sales assistance Pellet tank temperature control probe if the tank over heats the machine automatically modulates to return to normal temperature values in the applicable models Mechanical air pressure switch blocks the
22. aser forwards theinspection report and warranty validation copy 2 filled in completely within 8 days from the date of validation of the warranty The purchase date must be validated by the possession of a valid fiscal document issued by the dealer 2 The appliance is used as prescribed in the instructions manual provided with all products 3 The boiler is installed in compliance with the Standards in force with regard to the prescriptions contained in the installation use and maintenance manual relating to the product by qualified staff in possession of the legal requisites M D n 37 dated 22 January 2008 4 The client is in possession of the documentation which certifies its eligibility filled in in all its parts A INSTALLATION REPORT filled in by the installer B INSPECTION REPORT AND VALIDATION OF THE WARRANTY Filled out by the client dealer and a qualified technical assistance centre 5 The warranty document filled in and accompanied by the purchase fiscal document issued by the dealer must be kept and shown to the authorised technician in the event of intervention THE WARRANTY IS NOT CONSIDERED VALID IN THE FOLLOWING CASES 1 The warranty conditions described above have not been respected 2 Installation has not been performed with respect to the Standards in force regarding the provisions described in the manual book provided with the appliance 3 Negligence of the customer due to lack of or incorrect maintenance of the
23. ate safety zone Possible circulator anomaly TRAPDOOR FAULTY The A tomatie cl aningotthe burnipot Contact after sales centre is blocked The system pressure read by the pressure MINIMUM switch is too low Possible presence of air in the system Contact after sales centre PRESSURE ALARM Possible lack of water or leaks due to anomalies in some system component H20 PROBE H20 probe failure Contact after sales centre ALARM MAX H20 The pressure of the water has exceeded en vessels are not damaged ot PRESSURE ALARM the max threshold Check that the cold system is loaded at the correct pressure Extraflame ENGLISH WARRANTY CONDITIONS EXTRAFLAME S p A with offices in via dell Artigianato 12 Montecchio Precalcino VI guarantees this product for 2 two YEARS from purchase date for manufacturer and material faults The warranty becomes void in case the defect of conformity is not filed with the dealer within two months from date of its finding The responsibility of EXTRAFLAME S p A is limited to the supply of the appliance which must be perfectly installed following the indications contained in the appropriate manuals and books provided with the purchased product and in compliance with the laws in force Installation must be performed by qualified staff under the responsibility of the person entrusting him who will assume complete responsibility for the definitive installation and consequent good functioning of the product installed
24. ating system and of the appliance must be carried out on a regular basis according to the table below TYPE OF APPLIANCE INSTALLED lt 15kW 15 35 kw Pellet operated appliance 1 year 1 year Water operated appliances 1 r 1 r closed fireplaces thermo stoves thermo kitchens yea yea Boilers 1 year 1 year Fumes exhaust system 4 t of fuel used 4 t of fuel used For further details refer to the cleaning and maintenance chapter Inspection and maintenance report At the end of the inspection and or maintenance operations a report must be issued and released to the owner or person acting for him who must confirm its receipt in writing The report must indicate the situations encountered the action taken any components replaced or installed and any comments recommendations and requirements The report must be kept with the relative documentation In the inspection and maintenance report one must mention anomalies detected that cannot be removed which pose a risk to the safety of the user or serious damage to building 9 components that have been tampered with If anomalies as per above were detected the owner or person acting for him must be warned in writing in the maintenance report to refrain from using the system until the safety conditions have been fully restored The inspection and maintenance report must include the main information of the technician or company who performed the inspect
25. ction of domestic hot water not supplied by EXTRAFLAME S p A water products only The heat exchanger is excluded from the warranty unless an adequate anti condensate circuit is realised which guarantees a minimum return temperature of the appliance of at least 55 C only water products FURTHER CLAUSES The warranty also excludes any calibration or regulation interventions of the product in relation to the type of fuel or the type of installation The warranty is not extended if particulars are replaced No compensation will be paid for the time the product is inefficient This warranty is valid only for the purchaser and cannot be transferred WARRANTY INTERVENTIONS The request for intervention must be sent to the dealer or after sales assistance Centre The warranty intervention envisions the repair of the appliance without any charge as provided by the law in force LIABILITY EXTRAFLAME S p A does not grant any compensation for direct or indirect damage caused or depending on the product LAW COURT The Vicenza Law Court is elected as the competent court for any disputes Extraflame uExtraflame Riscaldamento a Pellet EXTRAFLAME S p A Via Dell Artigianato 12 36030 MONTECCHIO PRECALCINO VI ITALY FN 39 0445 865911 E 39 0445 865912 info extraflame it www lanordica extraflame com Extraflame reserves the right to vary the features and data shown in this booklet at any time and with
26. d box complete emptying and cleaning 9 Check air intake pipe and cleaning of the flow sensor Extraflame ENGLISH DISPLAYS DISPLAY REASON OFF Stove off START The start up phase is in progress PELLET FEEDING Continuous pellet feeding is in progress during the ignition phase IGNITION The ignition phase is in progress START UP The start up phase is in progress WORK The normal work phase is in progress MODULATION The stove is working at minimum Ee Automatic burn pot cleaning is in progress CLEANING FINAL CLEANING The final cleaning is in progress STAND BY Stove off waiting for re ignition due to an external thermostat The stove will only re start when the external thermostat makes a request COOLING A new ignition is attempted when the stove has just been switched off When the stove switches off one must wait for the complete shutdown of the fumes motor then clean the burn pot The stove can only be STAND BY re ignited when these operations have been performed HOFF Stove off due to water temperature over set As soon as the water temperature drops below the pre set parameters the stove will switch back on BLACK OUT The stove is cooling after a power cut STAND BY Once cooling is completed it will re start automatically ANTI FREEZE The anti freeze function is in progress as the H20 t is below the factory set thre
27. dispensable for correct combustion Do not leave the packaging elements within reach of children or unassisted disabled persons The hearth door must always be closed during normal functioning of the product When the appliance is functioning and hot to the touch especially all external surfaces attention must be paid Check for the presence of any obstructions before switching the appliance on following a prolonged standstill period The stove has been designed to function in any climatic condition also critical In particularly adverse conditions strong wind freezing safety systems may intervene that switch the stove off If this occurs contact the technical after sales service and always disable the safety system If the flue should catch fire be equipped with suitable systems for suffocating the flames or request help from the fire service This appliance must not be used to burn waste 9 Do not use any inflammable liquids for ignition During the filling phase do not allow the bag of pellets to come into contact with the product The majolicas are top quality artisan products and as such can have micro dots crackles and chromatic imperfections These features highlight their valuable nature Due to their different dilation coefficient enamel and majolica produce crackling which demonstrate their effective authenticity To clean the majolicas it is recommended to use a soft dry cloth If a detergent or liquid is used the latt
28. e wall or towards closed spaces is forbidden even with clear skies In particular it is forbidden to use flexible and extendible metal pipes The chimney should only receive the exhaust of the smoke duct connected to the appliance collective flues or conveying exhausts from hoods above cooking appliances of any kind or exhausts from other generators into the chimney itself or smoke duct are not allowed The smoke duct and the chimney must be connected with a continuity solution in order to prevent the chimney from resting on the appliance It is forbidden to have other air supply channels and pipes for plant engineering transit inside the fumes exhaust systems especially if over sized The components of the fumes exhaust system must be chosen in relation to the type of appliance to be installed in compliance with inthe event of metal chimneys UNI TS 11278 with particular attention to what is stated in the specification in the event of non metallic chimneys UNI EN 13063 1 and UNI EN 13063 2 UNI EN 1457 UNI EN 1806 considering especially temperature class pressure class fumes seal at least equal to the seal required for the appliance moisture resistance resistance to condensation class or level of corrosion and specification of the materials constituting the inner wall in contact with the fumes soot fire resistance class minimum distance from combustible materials The installer of the fumes exhaust system once the in
29. ed by children or unassisted disabled persons Do not touch the boiler when you are barefoot or when parts of the body are wet or humid The safety and adjustment devices must not be modified without the authorisation or indications of the manufacturer Do not pull disconnect twist electric cables leaving the boiler even if disconnected from the electric power supply mains Do not close or reduce the dimensions of the airing vents in the place of installation The airing vents are indispensable for correct combustion Do not leave the packaging elements within reach of children or unassisted disabled persons The hearth door must always be closed during normal functioning of the product Avoid direct contact with parts of the appliance that tend to heat up during functioning Check for the presence of any obstructions before switching the appliance on following a prolonged standstill period 94 999999 Extraflame ENGLISH The boiler has been designed to function in any climatic condition also critical In particularly adverse conditions strong wind freezing safety systems may intervene that swit