Home
Electra Elite IPK and Elite SAT End-User Manual - Doc
Contents
1. Figure 2 15 File Menu Wizard Accesses the Wizard Wizard is available for every feature offered in the Electra Elite IPK Electra Elite system Wizard provides all of the information necessary to program a feature All of the system data items necessary for programming the feature are grouped together The user can press the appropriate tabs to access system data and make the necessary changes Change Password Allows the user to change the SAT password System Hardware Manual 2 17 Document Revision 2a Electra Elite IPK Print Provides two print options Job Specifications and Designation Labels requires a standard inkjet or laser printer When Job Specifications is selected a menu is displayed There are three options for printing the Job Specifications printing a family group such as system wide trunk group or tenant printing a range of Memory Blocks or printing an individual Memory Block Designation Labels Electra Elite IPK SAT End User version does not support exporting data to the DESI Label printing software This menu item is disabled However if you chose to install DESI during SAT installation you can still run DESI separately by clicking the Windows START button and then selecting PROGRAMS DESI for Windows DESI Print Setup Allows access to the printer setup screen This allows the printer configuration to be modified Exit Exits the programming software If changes were made the technician is
2. Host Setup HaostnameIP Address H472 24 232 76 TCP Port Number 10000771 3000 i 0001 Fing Cancel Figure 2 3 Host Setup Screen O Hostname IP Address type the IP Address of the Elite LAN PC Programming Device to contacted System Hardware Manual 2 5 Document Revision 2a Electra Elite IPK O TCP Port Number type in the assigned TCP port that has been assigned to the device If the device has been contacted previously the IP Address will be displayed in the drop down list under Hostname IP Address and the TCP port number will be saved with the IP Address _ New Site When the New Site option is selected click the Setup button The IP Connection Screen will appear This screen allows the user to Search Configure Update Ping and Restore an Elite LAN PC Programming Device to factory defaults IP Connection Setup Select Site Site Name dew Site Save Delete Mew Device Settings Use DHCP IP Assignment Static IP Settings IP Address i Subnet Mask la e E 4 Default Gateway TCP Part Number Current Device Settings DHCP Enabled M IP Address Subnet Mask eg Default Gateway Dr TCP Port Number EDU Search Device Control Update Ring actam Default Close Figure 2 4 IP Connection Setup Screen Select Site This allows the user to create a profile for each device that can be connected to or to Delete a profile Curr
3. End User Manual All Call Page Alphanumeric Display Attendant Add on Console Automatic Day Night Switching Time Barge In Privacy Override Bilingual LCD Indication Customized Message Delayed Ringing Direct Station Selection DSS Distinctive Ringing Electric Volume Control Flexible Line Assignment Flexible Ringing Assignment Flexible Timeouts Full Handsfree Operation Handsfree Answerback Document Revision 2a Electra Elite IPK UO COCO UCC OU O O O L Headset Operation Internal Voice Tone Signaling Internal Zone Paging Meet Me Music On Hold MOH Night Transfer Off Hook Ringing Ringing Line Preference Speed Dial Station Speed Dial Stored Characters Speed Dial System Voice Prompt Selection It is no longer necessary to call an authorized NEC technician to program these basic system features Meeting the requirements of a company s day to day communications needs just got easier Electra Elite IPK Electra Elite SAT software makes programming the system easy You simply connect the PC that is running Electra Elite IPK Electra Elite SAT software to the KTS via a direct or remote connection Make the programming changes in SAT upload the changes from SAT and KTS and then exit Y SAT End User is compatible with PCs running Windows 95 98 ME XP 2000 or NT 4 0 or higher operating system and connects to the Electra Elite IPK Electra Elite KTS either directly using the serial cable included or remotely
4. F11 special function key provides a shortcut to this feature Document Revision 2a EEE BEN Bb EM Electra Elite IPK Accesses Quick Search Quick Search provides a detailed list of system data items The F8 special function key provides a shortcut to this feature Returns to the previous tab group The Shift F6 special function key provides a shortcut to this feature Advances to the next tab group The F6 special function key provides a shortcut to this feature Displays the help contents for the Electra Elite IPK SAT End User software program The F1 special function key provides a shortcut to this feature Scrolls up displaying the previous page Scrolls down displaying the next page Advances to the first page Advances to the last page Brings up the Connection dialog box The F7 special function key provides a shortcut tot his feature SAT End User Programming Electra Elite IPK Document Revision 2a SECTION 9 ELECTRA ELITE IPK ELECTRA ELITE PULLDOWN MENUS This section explains each of the pulldown menus that are available in SAT software File The File pulldown menu provides options for basic file management a Untitled Expanded Electra Elite IPK SAT File Edit Basic Application User Communications Help New pz Open Etrl 0 ES Es ha Save Chrl S E l Save S i Import Elite file Wizard Change Password Print k Print Setup Recent Eile r Exit gt
5. Indicates whether the data ath is connected to the lectra Elite IPK Electra Elite system System Data Item Pulldown Menu Screen a ve NEI EE I zas 4 Untitled Expanded Electra Elite IPK SAT Pill x File Edit Basic Application User Communications Help 4 Untitled Basic Electra Elite IPK SAT JEpd File Edit Basic Application User Communications Help oleji aa F2 s Greg Ds Ry SS SeA amp col e ajaj pernerenseneneensenseneseanseneg CO PBX Trunks Intercom DISA Paging Access Codes Station Base enneennsenneensevesesesenbeese LKH Speed Dialir a LKH el 1 co PBX Line y 13 Not Specified Call Arrival Keys 2 CO PBX Line X i Not Specified Forced Account Code 3 CO PBX Line E 15 Not Specified A4fcomsxime 16 Not Specter 5 corBxLine 17 Not Specified 6 cozPBX Line 18 Not Specified 7 co PBX Line 19 Not Specified 8 co PBX Line 20 Not Specified 9 Not Specified y Not Specified 10 Not Specified 22 No Specified Y 11 Not Specified gt 23 Nodpecified 7 12 Not Specified 24 Not Spdcified p 4lt BTM Basic Terminals Multiline E m Pulldown Menu Tab Groups Make selections by clicking on an The arrow indicates additional le indi item The associated de Aa is information is available for this Information Bar ao displayed
6. Section 6 Wizard on page 2 10 System Data Upload Download allows system data to be transferred from to a personal computer to provide backup of data System Hardware Manual 2 1 Document Revision 2a Electra Elite IPK SECTION 3 SOFTWARE INSTALLATION 3 1 Installing Electra Elite IPK Electra Elite System Administration Terminal SAT End User Software Important Consult your authorized NEC Dealer for proper setup of the KTS for SAT programming 1 Insert the SAT End User CD in your CD ROM drive 2 Click the Windows Start button 3 Select Run 4 Enter CD drive letter i e d 1ElitelPKSATEU exe and click OK 5 Follow the on screen instructions of the installation program 6 To start the SAT End User program Click the Start button Select PROGRAMS Electra Elite IPK EU SAT for End User Click Electra Elite IPK SAT EU Choose the following KTS Type gt lt S7000 This is used when system software is S7000 or below 8000 This is used when system software is 58000 only gt IPK This is used when the system is Electra Elite IPK R1000 or higher Enter the password The default password is PASSWORD in upper case letters SAT End User Programming Electra Elite IPK Document Revision 2a Password ETS Type C lt 57000 C Sa000 IPK Welcome to Electra Elite IFK SAT Cancel Figure 2 1 Password Screen SECTION 4 USING SAT When you first begin SAT End User all th
7. This option provides access to the help topics that are available for the Electra Elite IPK Electra Elite System Administration Terminal system Help Topics This options provides a list of help topics The user can bookmark topics that they may want to refer to again 2 26 SAT End User Programming Electra Elite IPK Document Revision 2a Show MB Numbers When enabling this option the memory block number is displayed above the cursor when positioning the cursor over a data field About This option provides information about the System Administration Terminal SAT End User software System Hardware Manual 2 27 Document Revision 2a Electra Elite IPK THIS PAGE INTENTIONALLY LEFT BLANK 2 28 SAT End User Programming Electra Elite IPK and EleckraGliic SYSTEM ADMINISTRATION TERMINAL SAT END USER MANUAL NEC America Inc Document Revision 2a Applies to Release R1000 through Release R2500
8. authorized NEC Dealer System Hardware Manual 2 23 Document Revision 2a Electra Elite IPK Communications The Communications pulldown menu allows access to system data items relating to direct and remote connections to the Electra Elite IPK Electra Elite system Untitled Expanded Electra Elite IPE SAT Oe a EGGE pla Downoad ET eh Rel eat sjef atico Figure 2 19 Communications Menu Connect This option allows the user to connect to the Electra Elite IPK Electra Elite system Disconnect This option allows the user to disconnect from the Electra Elite IPK Electra Elite system Upload This option allows the user to upload programming changes and configurations to the KTS SAT End User Programming Electra Elite IPK Document Revision 2a Download This option allows the user to download the current Electra Elite IPK Electra Elite configuration Verify This option allows the user to compare the configuration programmed in the KTS with that of the PC Setup This option allows the user to set up the PC serial port This is the serial port connected to the KTS System Hardware Manual 2 25 Document Revision 2a Electra Elite IPK Help The Help pulldown menu allows access to online help Untitled Expanded Electra Elite IPE SAT Figure 2 20 Help Menu Using Help This option provides access to the help topics window that describes how to use the help function Contents
9. option indicates the tab name Keyboard Shortcut Figure 2 14 Electra Elite IPK Electra Elite System Administration Terminal Software Screen Samples 2 14 SAT End User Programming Electra Elite IPK SECTION 8 TOOLBAR Document Revision 2a Several icons are provided to allow the user to navigate the program The icons in the toolbar are explained in this section The availability of the individual tools depends on the activity the user is performing When the icon appears shadowed the tool is not available When the icon is dark the tool is available Refer to Figure 2 14 Electra Elite IPK Electra Elite System Administration Terminal Software Screen Samples for an example me P e B System Hardware Manual Accesses the Job Specifications printing option Accesses the wizard for individual features The F10 special function key provides a shortcut to this wizard Sets the defaults for all items on the open tab Sets the defaults for the individual system data items on the screen the default is set for the item where the cursor is blinking Allows data items to be copied between ports The F3 special function key provides a shortcut to this feature Allows values between two ports to be swapped The F5 special function key provides a shortcut to this feature Allows the user to undo the current edits and return to the previous editing operation Allows the user to return to the previous editing operation The
10. using a modem Direct Connection this method is used when the PC is located at the KTS system serial cable connection between the PC and the Electra Elite IPK Electra Elite KTS is required Remote Connection this method is used over telephone lines when the KTS is located at a remote location A modem in both the PC and the KTS is required IP Connection this method is used over a LAN WAN network in conjunction with the Elite LAN Programming Device allowing a PC connected to the LAN WAN to remotely program the Electra Elite IPK Introduction ecra Elite PK SAT End User Programming CHAPTER 2 SECTION 1 SECTION 2 PC REQUIREMENTS This manual provides detailed information for programming using the Electra Elite IPK Electra Elite System Administration Terminal SAT End User software PC requirements Y Pentium Processor Microsoft Windows 95 98 ME XP 2000 or NT 4 0 or higher operating system At least 13 MB of free hard disk space Unused PC serial communication port Luv wv MNP Class 4 or V 42 bis modem if remote programming is required FEATURES OF SAT END USER PROGRAMMING Some of the features of SAT End User Programming include Wizard allows a user to select a feature using wizard Wizard prompts the user to program the necessary system data items associated with the feature When wizard is selected a tabbed list of information is provided For a detailed discussion of wizard refer to
11. NOTICE Note that when converting this document from its original format to a pdf file some minor font and format changes may occur causing slight variations When viewing and printing this document we cannot guarantee that your specific PC or printer will support all of the fonts or graphics Therefore when you view the document fonts may be substituted and your individual printer may not have the capability to print the document correctly NEC Electra Elite IPK and Eleckracliic gt A a F E H bed pe O BULL DA i y Ay SYSTEM ADMINISTRATION TERMINAL SAT END USER MANUAL CD Stock Number 750837 Document Revision 2a Applies to Release 1000 through Release 2500 Contents of this manual are subject to change without prior notice at the discretion of NEC Unified Solutions Inc This document has been prepared for the use of employees and customers of NEC Unified Solutions Inc and may not be reproduced without prior written approval of NEC Unified Solutions Inc pierm Electra Elite and ElectraMail are registered trademarks of NEC America Inc Windows is a registered trademark of Microsoft Corporation AT amp T is a registered trademark of AT amp T Wireless Services Inc Copyright 2004 NEC America Inc 6535 N State Highway 161 Irving TX 75039 2402 Technology Development y TABLE OF CONTENTS Chapter I Introduction Section 1 Chapter 2 Section 1 Se
12. Programming Device with the new settings The Ping option can be used to verify that the device is able to be reached the Factory Default button is used to restore the unit back to default settings Once the configuration has be accepted a confirmation letting you know that the device was configured successfully appears Device update Configuration a UL Device has been configured successtully Figure 2 9 Successful Configuration Screen Click the OK button and then close the IP Connection Setup window Now you are ready to connect to the Elite IPK System by using the Connect Screen Connection Type Connect C Direct Connection fr IP Connection Bia C Modem Connection New Site Direct Ethernet Setup EEE Cancel Click Connect or Dial to connect to KTS Figure 2 10 Connect Screen System Hardware Manual Document Revision 2a Electra Elite IPK O Inthe drop down list choose the site that was previously created and click the Connect button The following information will be displayed to indicate the system s IP address Refer to Figure 2 11 IP Address on Connect Screen Connection Type rippin Ptonnection Wal anden leonnectan Setup Elite IPE Basic Cancel Connecting to KTS System Please Walt 172 24 232 77 10001 Figure 2 11 IP Address on Connect Screen O Once connection is established proceed with Uploading or Downloa
13. Wizard on page 2 12 The Flexible Line Assignment feature is selected Back Next Untitled Basic Electra Elite IPK SAT File Edit Basic Application User Communications Help 1 al elel alejo a e le el e svev CAP Key Auto Assign Tab LK forine 1 Jeomextine l 13 Not Specified Jl selected 2 compaxtine I 14 Not Specter wizard 3 CoPBXLine y 15 Not Specified y a coxim 16 Not Specified 5 co PBX Line 17 Not Specified 6 co PBx Line y 18 Not Specified 7 fcomexune 19 Not Specter fcomexime I 20 Not Specifiea 9 Not Specified 21 Not Specifier 10 Not Specifiea 22 Not Specified 11 Not Specifiea y 23 Not Specified 12 INotSpecified 24 Not Specie Alt F2 Wizard mode Figure 2 13 Sample Wizard PROGRAMMING SCREENS Main Menu When the SAT software program is launched the first screen that is displayed is the Main Menu screen This screen allows the user to access the options used to program the Electra Elite IPK Electra Elite system Figure 2 14 Electra Elite IPK Electra Elite System Administration Terminal Software Screen Samples shows the menu and describes the layout Pulldown Menu Pulldown menus are available for each function involved in programming the Electra Elite IPK Electra Elite system To access the da
14. ction 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section 8 Section 9 General Information ari 1 1 SAT End User Programming FOG FEE sank E 2 1 Features of SAT End User Programming s vrannvnnnnnnnnnnnnunnnnnnnnevnnnunnnnn 2 1 Software Installation ca ada A 2 2 3 1 Installing Electra Elite IPK Electra Elite System Administration Terminal SAT End User Software oooccccccccccnncoconnccccnocancnnnnnonanons 2 2 Te SAL Aaa 2 3 IP Connection Configuration ernnnernnnnnnnnnnnnnnnnennnnnennnnnennnnnevnnnvennnn 2 4 5 1 Configuring SAT to Communicate via LAN WAN rruunnnrnnnrrrnarrvnnnennnr 2 4 NN 2 10 Programming Screens ernnnnnnnnnnnnnnnnnnnennnnnnnnnnnnvnnnnnnnnnnnnneennnnnennnnnne 2 12 TONI cra i 2 15 Electra Elite IPK Electra Elite Pulldown Menus snrrnnnvennnnnnnnvennnunn 2 17 SAT End User Manual Document Revision 2a THIS PAGE INTENTIONALLY LEFT BLANK Electra Elite IPK Table of Contents Figure 2 1 Figure 2 2 Figure 2 3 Figure 2 4 Figure 2 5 Figure 2 6 Figure 2 7 Figure 2 8 Figure 2 9 Figure 2 10 Figure 2 11 Figure 2 12 Figure 2 13 Figure 2 14 Figure 2 15 Figure 2 16 Figure 2 17 Figure 2 18 Figure 2 19 Figure 2 20 md Y 9 pull O 7 C Cc AS 17 o PN esses rine sips ee oe peg ates yt es pase sane aac eee 2 3 INTE Eve 2 5 aio dl 2 5 IF Connection Seip DOO EE 2 6 Search Tof Device SOGE esel 2 7 Device Search Results Screen rrrnrrrnrannnrnnn
15. ding the system data SECTION 6 WIZARD The wizard organizes system data assignments for programming individual features When the user selects wizard the system provides a tabbed list of information related to the selected feature Wizard can be accessed by using the wizard button from the toolbar or by selecting Wizard from the File pulldown menu A Select from the toolbar 2 10 SAT End User Programming Electra Elite IPK Document Revision 2a When wizard is displayed the user can select any feature from the list or can begin entering letters of the feature name As the name is being entered Quick Search finds the matching letters and highlights the match System Hardware Manual Account Code Entry Account Code Forced Yernfed Unvented Account Code Forced ented A dd Un Conference All Call Page Alphanumenc Display Ancillar Device Connection Answer Hold Answer ke Assigned Might Answer AMA Attendant Add on Console Attendant Camp On Attendant Positions Attendant Station Qutgoing Lockout Attendant Transfer Authorization Code l Cancel Figure 2 12 Selecting Wizard for a Feature Document Revision 2a SECTION 7 Electra Elite IPK When a feature is selected all system related data items for that feature are presented in sequence Enter the required values in the current tab and click next to advance to the next tab Click back to go to previous tab In Figure 2 13 Sample
16. e buttons and menu items are disabled grayed out except for these menu items COMMUNICATIONS CONNECT SETUP T Important To enable the menu items you must first connect to the KTS using the following procedure 1 Select COMMUNICATIONS SETUP PC SERIAL PORT 2 Choose the PC COM Port that is connected to the KTS The serial cable pro vides a direct connection to the KTS while a modem provides for a remote con nection 3 Set up the baud rate and line settings 4 Fora direct connection install the serial cable provided from the PC serial port selected in Step 2 to COM1 on the KTS For a modem connection when the KTS is at a remote location connect a modem to the SAT PC See your authorized NEC Dealer for configuration of the KTS for modem connection For IP connection use the Elite LAN Programming Device connected to the KSU See your authorized NEC Dealer for installation of the Elite LAN PC Programming device System Hardware Manual 2 3 Document Revision 2a Electra Elite IPK 5 Select COMMUNICATIONS CONNECT and choose either DIRECT MODEM or IP CONNECTION Refer to Section 5 IP Connection Configuration for the procedures for setting up the SAT End User program when IP connection is selected 6 Enter a password if the KTS requires one See your authorized NEC Dealer for password information 7 Click the CONNECT or DIAL button depending on the type of connection 8 Once a connection is establis
17. ent Device Setting This shows the current device s IP Address Subnet Mask Default Gateway and TCP Port Number lf a New Site is selected in the Select Site drop down list the Search option can be used to search the Network for Elite LAN PC Programming Devices in the following Subnets Class C and Class B Once the Search Button is chosen the following screen will appear SAT End User Programming Electra Elite IPK Document Revision 2a Search for Device A e Class B Network Subnet mask 255 255 0 0 Figure 2 5 Search for Device Screen Select the appropriate Subnet that the PC and the Elite LAN PC Programming Device is located in and click Search Once a device is found the Device Search Results screen shows the available device s to be configured If no devices are found a message will be displayed stating that no devices were found Device Search Results FT The following Devices have been found on the network Select the desired device to be configured MAC Address 00 40 48 4 B E4 Figure 2 6 Device Search Results Screen O Select the device and click OK System Hardware Manual 2 7 Document Revision 2a Electra Elite IPK The IP Connection Setup Screen will open with the current Device Settings IP Connection Setup Select Site Site Name New Site Save Delete Current Device Settings Mew Device Settings DHCP Enabled M IY Use DHCP IP Assignment GENE EEE Note If
18. hed Electra Elite IPK SAT EU will automatically perform a complete download of all system data from the KTS to the PC 9 When downloading is completed all the menu items and buttons are enabled Begin programming the features using the various menu items in SAT 10 Complete programming Select COMMUNICATIONS UPLOAD and press the Start button to upload all of the changes and programming to the KTS closing Electra Elite IPK SAT EU all programming and changes SAT End User cannot save any data to the PC hard disk When are cleared from the PC SECTION 5 IP CONNECTION CONFIGURATION When the IP connection is used the Elite LAN PC Programming Device must be installed 5 1 Configuring SAT to Communicate via LAN WAN 1 With SAT already open click COMMUNICATION CONNECT The Connection Type screen appears 2 4 SAT End User Programming Electra Elite IPK Document Revision 2a Connection Type Connect Direct Connection fe IP Connection Dial Modem Connection New Site a Setup Cancel dd Click Connect or Dial to connect to KTS Figure 2 2 Connection Type Screen 2 Ensure that the IP Connection is selected 3 From the drop down list chose from the two available options 1 Direct Ethernet O When the Direct Ethernet is selected click the Setup button The Host Setup Screen will appear O This screen allows the IP Address and TCP Port of an already installed device to be assigned
19. ic Menu Terminals This option allows the user to assign terminal related assignments to the system Several selections are available with this option _J System Wide Y Station Base I Multiline Y DSS BLF System Hardware Manual 2 21 Document Revision 2a Electra Elite IPK CO PBX Trunks This option allows user to program system data related to trunk assignments One selection is available with the System Wide option Intercom This option allows the technician to program system data related to intercom assignments Speed Dialing This option allows data related to system and station speed dialing to be programmed System Timers This option allows the user to change the Call Forward Busy No Answer and CO PBX incoming Ringing Alarm tone Forced Account Codes This option allows the user to assign account codes SAT End User Programming Electra Elite IPK Document Revision 2a User The User pulldown menu allows access to system data items related to speed dialing 2 Untitled Expanded Electra Elite IPK SAT Aa ES ans fal ep el ARS Figure 2 18 User Menu Speed Dialing This option allows the user to program both System and Station Speed Dial memory locations Each Multiline Terminal in the Electra Elite IPK Electra Elite can be assigned individual speed dial numbers Station Speed Dial can be denied in System Programming If no Station Speed Dial memory locations are available consult your
20. nnrnnnnnrnnnnnnnnnnrnnnnnrnnrnnnsnnnnnrnnnnnnnnnsnennnn 2 7 Example of IP Connection Setup rnarisanr cid iii 2 8 Fo a AS enn ee nr eee ee Ae ne eee ate 2 8 Successful Configuration Screen ccccooccnnococononnnncnonononnnnnonnnnnonannnnonannnonannnonannnnanss 2 9 Connect Screen ii di 2 9 IFP Adaress ON Connect SOON seie 2 10 Selecting Wizard for a Feature rrrrrnrrnnrnnnernnnnerrnnrrnnnnrnnnnnennnnrsennnnsnnnnnrnnnnsennnnee 2 11 Sampie A E REEERE EEE 2 12 Electra Elite IPK Electra Elite System Administration Terminal Software Screen Samples ccccccesssececsseecceesecccencesceneesceseceanseceeneecceaeeescesesscesessoeeessaeees 2 14 FI Jr 2 17 Edit Menu sund O pe ORO r datdsadrebdsdet 2 19 FO TN 2 21 FN 2 23 NN NTN 2 24 A inne rion A ret erry evr aen te anew 2 26 lil SAT End User Manual Document Revision 2a THIS PAGE INTENTIONALLY LEFT BLANK Electra Elite IPK List of Tables Introduction SECTION 1 GENERAL INFORMATION ecra Elite PK CHAPTER 1 Congratulations You have purchased the System Administration Terminal SAT End User program for the Electra Elite IPK Electra Elite Key Telephone System The SAT End User is a user friendly Windows application that allows the user to program and configure several features of the Electra Elite IPK Electra Elite KTS from the PC environment This application allows the customer to change certain end user based parameters such as UC CO COUCOU CUCO O OU O O SAT
21. prompted to upload the changes before the program shuts down SAT End User Programming Electra Elite IPK Document Revision 2a Edit The Edit pulldown menu allows files to be edited swapped defaulted or copied al ES gt Spiel El Seb fre SEDE anita Figure 2 16 Edit Menu Undo Allows the user to undo current edits and return to the previous editing operation Copy Brings up the copy screen This allows port information to be copied from one port to another Swap Allows values between two ports to be swapped Set Default Defaults to the current field where the cursor is positioned System Hardware Manual 2 19 Document Revision 2a Electra Elite IPK Set Default All Allows the user to set all values to default on the open tab Quick Search Allows the user to search the Memory Blocks by Memory Block Number Memory Block Name or Tab Name After the search method is specified a list is provided The user can scroll through the list and click on the desired Memory Block System data can then be modified as necessary SAT End User Programming Electra Elite IPK Document Revision 2a Basic The Basic pulldown menu allows access to basic end user programming items amp Some menu items may be disabled if the appropriate hardware is not assigned or a dependent data item is not set Untitled Expanded Electra Elite IPK SAT Aa x j p i Tal p ent Effective Elite Figure 2 17 Bas
22. ta associated with the function click on the function name on the Main Menu Some of the options on the initial pulldown menu offer several selections An arrow to the right of the option name indicates SAT End User Programming Electra Elite IPK Document Revision 2a additional selections are available Refer to Figure 2 14 Electra Elite IPK Electra Elite System Administration Terminal Software Screen Samples for an example of a Pulldown Menu System Data Screen When an option is selected from a pulldown menu a screen is displayed that allows the user to program data for the function selected Figure 2 14 Electra Elite IPK Electra Elite System Administration Terminal Software Screen Samples shows an example of a System Data Screen This screen indicates three tabs The tabs indicate system data items that are grouped together for programming The active tab group is indicated by a box around the tab title To access another tab group press the tab or use the keyboard shortcut Keyboard shortcuts are displayed at the bottom of the screen in the Information Bar System Hardware Manual 2 13 Document Revision 2a Electra Elite IPK Main Menu Pulldown Menus Untitled Expanded Electra Elite IPK SAT Piel ES Help File Edit Basic Application User Communications Help Accesses help Z co Cal Ze ES amp PI aj e 2 2 v 3 x information Electra Elite IPK SAT NEC Connection Status
23. the DHCP server allocates a new IP Subnet Mask 255 255 255 255 address for the Ethernet Device on a penodic Hernes aa basis itis recommended to use Static IF KE address or Static Mapping in the DHCP TCP Port Number fi 0001 server allocation tables TCP Part Number i 0007 Figure 2 7 Example of IP Connection Setup O Once the Elite LAN PC Programming Device is located configuration can be performed IP Connection Setup x Select Site Site Name Yew Site Save Delete Mew Device Settings T Use DHCP IP Assignment Static IP Settings IP Address HE Subnet Mask HETE Default Gateway H R TCP Port Number Current Device Settings DHCP Enabled M IP Address Subnet Mask rm Default Gateway es sen TCP Port Number Search Device Control Update Pi a Factor Wetan Figure 2 8 IP Connection Setup O Using the New Device Settings the following items can be configured DHCP Yes or No IP Address Subnet Mask Default Gateway TCP Port Number m IfDHCP Service is selected a static IP Address can not be assigned When the Use DHCP IP Assignment is unchecked then the IP Address Subnet Mask Default Gateway options will be allowed SAT End User Programming Electra Elite IPK Document Revision 2a Once the appropriate selections have been made click the Update button to update the Elite LAN PC
Download Pdf Manuals
Related Search
Related Contents
Dali Zensor Vokal 家庭 一 取扱説明書 Yarga and Bularoo EZ-pump guide VistaQuest VQ1100 User's Manual Defford cum Besford Village Hall 下水道用丸型鉄ふた - 日之出水道機器株式会社 500 millas Categoria 3 2012 OWNER`S MANUAL MANUAL DEL PROPIETARIO Copyright © All rights reserved.
Failed to retrieve file