Home
Embed-It! Integrator Online
Contents
1. Page iv Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Chapter 1 Introduction 1 1 The Benefit to Virage Logic Customers Integrator Online provides you access to the functionality of Virage Logic s Embed It Integrator software If you are a System on a Chip designer evaluating Virage Logic Products you can generate memory instances and study the trade offs between memory core types and variants You can thus make better decisions about the suitability of Virage Logic intellectual property for inclusion in your designs If you are a designer considering Virage Logic s Compiler Tools you can use the software without having to install it on your own computers Integrator Online is available both as a client side Java application deployed using Sun s Java Web Start technology and a browser based tool The interface of the browser based and client side Java versions of Integrator Online are almost identical to each other and also very similar to Embed It Integrator However the client side Java version of the tool has many features that make the usage customization and generation of memory instances as easy as possible Hence it is recommended that you use the client side Java application instead of the browser based tool wherever possible An Integrator Online command line client is also available for execution and can be used according to instructions in Chapter 3 Integrator Online Comm
2. for which data will be generated during the instance generation process Three operating points are already listed when you start setting the parameters each with a Process condition Operating Voltage V and Junction Temperature C already defined Click the New button to add an operating condition or the Edit button to change the parameters for an existing operating point In either case the PVT window appears as shown in Figure 2 5 PVT Window below Figure 2 5 PVT Window x Process Condition T Typical Operating Voltage Junction Temperature C Name Specify the Process Condition Operating Voltage V and Junction Temperature C and assign a Name to the operating point you are adding or changing Just like the General Parameter Window as you click in each field and enter values for the operating parameters Integrator Online shows you the allowed values and ranges for each parameter in the Status Area at the bottom of the window When you download the output files for an instance Integrator Online creates a subdirectory under the instance directory for each operating point The Name you specify for each operating point in the above window becomes the name of the subdirectory If available for the specific compiler enter modify the bias voltage values to be used for corner definition Click the Ok button in the PVT Window after you finish adding the new operating point or making the
3. view in the views subtree in the Project Tree and select Component gt Show View menu option You can also double click the selected view in the Project Tree In either case it displays the contents of the selected file in the Views area Components with status NOT GENERATED have only the Configuration file available for preview in the Views area You cannot change the values of the components directly in the Views area Only text and HTML files can be viewed in the Views area Any external reference in HTML files will be opened in a separate Internet browser window for preview Binary files such as GDS must first be downloaded in order that you can preview them with the corresponding software Just as with the Messages area you can show the Views area only by using the button 2 2 3 Deleting a Component To delete a component from the project simply highlight its name in the Project Tree and select Component gt Delete menu option This will remove the component from the Project Tree Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Page 15 2 3 Disconnecting and Exiting Use the Project gt Disconnect menu option to disconnect from the server and the Project gt Exit menu option to exit the Integrator Online When you disconnect the connection with the server the Integrator Online Login Window shown in Figure 2 1 Login Window appears When you exit the Integrator Online thi
4. W vs USER MANUAL Embed It Integrator Online Release E 2011 03 March 2011 c 1998 2011 Virage Logic Corporation All Rights Reserved copyright notice reflects distribution which may not necessarily be a publication Virage Logic Corporation 47100 Bayside Parkway Fremont California 94538 USA This product and document are protected by copyright and distributed under licenses restricting their use copying distribution and decompilation The material in this manual may not be reproduced adapted merged translated stored or used without prior written approval of Virage Logic RESTRICTED RIGHTS LEGEND Use duplication or disclosure by the government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 and FAR 52 227 19 The product described in this manual may be protected by one or more U S patents foreign patents or pending patent applications TRADEMARKS AND REGISTERED TRADEMARKS The license manager portion of this product is based on FLEXIm license Manager from Macrovision Corporation All Virage Logic products ASAP Memory and ASAP Logic FirstPass Silicon Characterization Lab Intelli MDDR Intelli PHY DLL and Intelli Models SiWare Memory and SiWare Logic STAR Memory System STAR Yield Accelerator emPROM Memory System Silicon Aware IP and System Aware IP are trademarks of Virage L
5. WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT SWDV 0156 Contents COWON nompne iii Chapter i IRICEN ssnin EE N 1 1 1 The Bencht to Virage Losic C a iach asec h cSccusisatsccnsasass auuuad a 1 1 2 What You Need to Run Integrator tin ooo cxsnsecareaseeeiantssateeentia asuadesatoussdaiesedds 1 Chapter 2 Running the Integrator Online ccccsesseeeeeeeeeeeeeeeeeeeeeeeeseeeeeeeeeeeenseeeeeeeees 3 21 Working with Memory ComponeMiS eessen a ea nee E 6 ii Creating a New Component xcccnuacunundesde nena fi sla MOULIN aL TOON ein E E 13 Zia Sse Me oe Componian E R 13 214 Downloading the Generated FileSssiisrsisinin a 14 2 2 Perrine Certain Tasks on Caen sruron na 14 22 Editing the Selected COMPONEN rcis reiia iA 15 2 2 2 Showing the Output View for a Selected Component eeeeeeeeeseereeerereereresse 15 Tao Delga C CM cts doi tocar esas R E A A N 15 23 Dieconiectine and ESINE siena A E 16 Chapter 3 Integrator Online Command Line ACCESS sssssssssunnnnnnnnnnnnennnnnnnn nennen nnn 17 Appendix A OUTPUT File StruCt re scssiddercsicicisnasaasasiccedccinssanasactiniaincnninadeiaidaeeendaninaiacasan 19 Index aati aratcenccincr ina cc aaaea asasini aee kisinan aaa aiani 21 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Page iii
6. a A E Typical Freq 300 008000 G Worst NB 4 Bit Browser NW 64 Bi Combined Datasheet for all PV PR_WIDTH_AUTO 1 C Configuration compiler name iblZs2p2Zhssb02 C Coordinates licensekey analyzer 4 sos memory name hsss2_64x4cem4bk1 O Hercules Hierarchical LYS Cell G hsss2_64x4cm4bk1_ppr log HTML Datasheet for all PVT cor O Log Messages 4 Physical LEF Version hwbU2 sw 5 5 0_alpha z G Template mask numbers Metric 25769 568 Q Oe v2ss1_256x64cm16 INFO MC MC 131 Adding VSIA tag took 0 07 secs a views INFO MMC YMC 130 Complete component generation took 10 DY connguration INFO MC VMC 046 Grrors 0 Warnings 1 WARN MMC CFG 003 7Nested comment opened at line 50 of fil Status Bar The Project Tree The Messages Area This window has the menu bar the toolbar below the menus and the status bar at the bottom The area between the toolbar and the status bar is occupied by a three part window There is a Project Tree that appears when you create a new component or import an existing component into your project The Project Tree shows the components by their names and associated views Indicator lights for each component in the Project Tree provide the status of each action run on the component Gray means that the component has not been generated yet Green means successful run without Errors or Warnings Red means Errors Warnings are encountered during ru
7. anced parameters As an example a subdirectory for the instance mentioned above might include the following ts128x8cm4 ds Datasheet ts128x8cm4 llef Logical LEF ts128x8cm4 summ Summary ts128x8cm4_stim v Testbench for Verilog Behavioral Model and Verilog Netlist ts128x8cm4 v Verilog Model ts128x8cm4 vhd Vital Model VHDL ts128x8cm4_qa txt Compiler QA Information ts128x8cm4 lib Synopsys Model ts128x8cm4_vhd_stim v Verilog Behavioral Model and VHDL Behavioral Model Testbench ts128x8cm4_vhd_wrapper v Verilog Wrapper for VHDL Page 20 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate A Abort 12 Advanced Parameters window 11 Automatic Memory Naming 9 B Bits in Word 8 C Client side Java 1 Column Mux Option 8 Command Line Options 15 D Deleting a Component 14 Downloading Files 12 E Editing Selected Component 14 Embed It Integrator software 1 Embed It Integrator software 1 Exit Codes 15 F Frequency in MHz 8 Front end views 17 G Generating a Component 12 Index Import a Component 12 Instance directory 17 Integrator Online Account Administrator 3 Integrator Online Command Line Client 15 Integrator Online Benefits Integrator Online Interfaces 1 IOL Key 3 15 J JAVA Web Start 1 Junction Temperature C 9 Junction Temperature C 9 JWS 3 N Number of Banks 8 Number of Bits in Subword 9 Number of Vertical Banks 9 Number of Wo
8. and Line Access on page 17 1 2 What You Need to Run Integrator Online All you need to be able to run Integrator Online as a client side Java application is a Java Runtime Emvironment JRE 1 4 2 and Java Web Start software The Web Start software is available free of charge at http java sun com products javawebstart The default locale for Integrator Online is set to English US To run the browser based client you need an active Internet connection and a Java 1 1 enabled browser Once a Virage Logic staff member has set up an account for you you can simply go to the URL they provide you log in and start using the tool Copyright 1999 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Page 1 Page 2 Copyright 1999 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Chapter 2 Running the Integrator Online Once your Integrator Online account has been created you will receive an email from the Integrator Online Account Administrator providing you with your User Name and IOL Key as well as the URLs for the browser based and client side versions of Integrator Online To run the client side Java version of Integrator Online simply enter the URL for that version into any browser window The application will be downloaded and launched as shown in Figure 2 1 Login Window Integrator Online supports HTTPS connection for secure instance generation Note that thi
9. changes to an existing one This will save the changes you made and take you back to the window with parameters in the General Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Page 9 tab Clicking Cancel discards any changes to the operating points and takes you back to the to the window with parameters in the General tab Use the check boxes in each PVT row to enable or disable a PVT A selected check box for a PVT means that this PVT is enabled and will be generated while running component generation A deselected one is greyed out and means that it will not be generated while running component generation Using the check box in the header of the PVT table you can enable or disable all PVTs Enable Process FFQB 0 99 TTDB 0 9 SSDB SSDB SoD FFQB 0 99 New Edt Delete Defaults Run Instance Characterization OOO n A fE On the General tab clicking Ok saves all the settings including memory parameters and PVT conditions that define the compiler output files Clicking the Defaults button in the General tab restores all PVT values to their default values Clicking Apply keeps the Configure Component dialog open for you to enter edits for additional component configurations based on the same compiler Any PVT that matches a user characterized corner in the characterization database cannot be edited or deleted Upon edit or delete operations an error message is d
10. ction correctly which is accompanied by Logging out text message in the command line The next connection session may be established as soon as the interrupted connection is closed Page 18 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Appendix A Output File Structure Integrator Online s output files reside in the instance directory The instance directory contains back end files for building the memory as well as a subdirectory for each operating point The subdirectories each contain a set of front end views for the respective operating point The names and number of files in each sub directory is the same For example if you specified an instance named ts128x8cm4 and operating points named Best Typical and Worst the instance directory will contain the following files and subdirectories ts128x8cm4 cfg Configuration File ts128x8cm4 eds GDSII File ts128x8cm4_func v Verilog Netlist File ts128x8cm4 cir Spice Netlist File rami ts128x8cm4 Abstract LEF File ram1 ts128x8cm4 Log File Best Subdirectory containing Front End Views for Best Operating Point Typical Subdirectory containing Front End Views for Typical Operating Point Worst Subdirectory containing Front End Views for Worst Operating Point Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Page 19 The contents of the subdirectories depend on the values for various adv
11. e component has not been generated yet Green means successful run without Errors or Warnings Red means Errors Warnings are encountered during run When you want to generate a component only those components that have gray and red indicators lights in the Project Tree can be generated Selecting Run gt Generate menu option starts the generation process of a selected component Selecting the Run gt Generate All menu option starts the process of generating the instances that have Not Generated status in the Project Tree In either case this will display the progress of the generation process while it is taking place in the Messages Area The Status Area in the lower left hand corner of the Main window informs you of progress while the generation is in progress During this time only the Abort toolbar button is active The Messages Area in the Main window displays the progress of the process as it happens When instance generation is complete the Status Area says Ready You can now see all generated instances in the Project Tree with the status changed to Generated The scripts list is displayed in the Run gt Script menu of Integrator Online if there are scripts installed for your account Generate All FS Generate F5 Script gt om_script ustom_script_2 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Page 13 Select the script you want to execute To terminate a
12. e generation of all licensed views Clicking the Advanced tab on the Configure Component dialog takes you to the Advanced Parameters window This window contains a number of additional parameters that control the instance and associated Views generated by Integrator Online The Advanced Parameters window comes up with Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Page 11 these parameters set to their default values as shown in Figure 2 7 Advanced Parameters Window below Figure 2 7 Advanced Parameters Window x General Views Advanced Compiler Information METAL1 METAL2 METAL3 VIA12 VIA23 B ADR 0 AAT 0 bus_max_transition 2 0 bus_name_intix chkbrd_alg_enable clk_max_transition Ok Apply Cancel For parameters that have a range Integrator Online shows you the allowed values and ranges in the Status Area at the bottom of the window Use the Advanced Parameters window when you need to generate an instance with more specific settings than the basic parameters in the General Parameters window can provide These parameters are a subset of the Embed It control parameters that are available to the user of Virage Logic s Embed It Integrator software Click the Ok button to save any changes you specify for the advanced parameters Clicking Cancel discards any change to the advanced parameters Clicking Apply enables you to apply chna
13. ges to the additional component that you configure based on the current compiler The component you have created and configured will be displayed and highlighted in the Project Tree You can also click Apply to keep the Configure Component dialog open to enter edits for additional component configurations based on the same compiler Use the Compiler Information tab to Page 12 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate view the compiler identification information including target foundry Foundry process geometry Process compiler name Compiler and compiler revision level Revision 2 1 2 Importing a Component Existing components can be imported into an Integrator Online project from other projects using the Component gt Import menu option Different components and variations have just one type of configuration file cfg that can be read by Integrator Online In the Import Component dialog select the Configuration Files cfg options in the Files of Type field Browse over to the cfg file you want click on it in the browse pane and press Import to import it Note that trying to import the same component twice will cause Integrator Online to produce an error saying that duplicate instance names are not allowed 2 1 3 Generating a Component Indicator lights for each component in the Project Tree provide the status of each action run on the component Gray means that th
14. hile the files are downloaded only the Abort button is active in the Download dialog Use the Abort button if you want to stop downloading the files and the Close button to close the Download dialog when the download is complete If you want to download a view simply highlight its name in the Project Tree and select Project gt Download gt View menu option In the Save As dialog browse over to or create a directory where you want your views to be downloaded to and press the Save As button This will start the process of downloading the selected views into the download directory you defined While the files are downloaded only the Abort button is active in the Download dialog Use the Abort button if you want to stop downloading the files and the Close button to close the Download dialog when the download is complete 2 2 Performing Certain Tasks on Components Integrator Online menu bar has a number of menu options that help you perform certain tasks on already created components e Edit the selected component See Editing the Selected Component on page 15 e Show the output view for a selected component in the Views area See Showing the Output View for a Selected Component on page 15 e Delete the selected component from the Project Tree See Editing the Selected Component on page 15 Page 14 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate e Generate all components
15. ightly different for two or more compilers of the same type depending on the features available for that compiler The general instance parameters to supply are e The Number of Words in the instance e The number of Bits in Word for the memory instance e The Column Mux Option or number of physical columns per I O pin It provides the set of valid CM values and identifiers for the various estimated aspect ratios for the compiler You can select the CM from the values in the pull down list The options available in the pull down list will vary depending on the values set for Number of Words and Number of Bits e The Frequency in MHz at which the memory instance is to operate e The Write ports for the memory instance e The Read ports for the memory instance e The Number of Banks horizontal banks for the memory instance Page 8 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate e The Number of Vertical Banks for the memory instance e The Number of Bits in Subword for the memory instance e The Signal Metal for the memory instance e The Redundancy enable for the memory instance true for a STAR and false for an ASAP memory e There is also a check box for Automatic Memory Naming If you check this box the Memory Name field will be filled in automatically for you On the right hand side of the General Parameters window you can define and edit the operating points or PVT conditions
16. in the project See Generating a Component on page 13 e Abort running the job See Generating a Component on page 13 Most of these options are realized as toolbar buttons and popup menus that open upon right click on a component or its view in the Project Tree 2 2 1 Editing the Selected Component The Edit and Delete commands in the Component menu of the Integrator Online let you perform editing and delete operations on the component currently selected in the Project Tree These commands work in the same way as Edit and Delete commands that appear in the popup menu upon right click on the name of the component in the Project Tree You can also use the JE and T toolbar buttons to perform the editing and delete operations on the selected component If you select Component gt Edit menu option it displays the Configure Component dialog where you can change the general and advanced parameters for the selected component as required or view the compiler identification information for the component on the Compiler Information tab in the Configure Component dialog Click the Ok button when you finish your edits to save the changes This operation cleans the views for the former component if it was generated and changes the state of the new component to NOT Generated 2 2 2 Showing the Output View for a Selected Component The Views area allows you to look at the compiler output views generated for the component Highlight the desired
17. isplayed warning that the given user characterized corner can only be enabled or disabled for instance generation The Views tab lists the views you can generate for a given memory These define the output files that will be generated for the memory Views available for the compiler you selected but which you do not Page 10 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate have a license for will be grayed out You can select which specific views have to generated for your memory Figure 2 6 Configure Component Dialog Views Tab 4 Configure Component xi General views Advanced Compiler Information Front End Views CO Generate a routing abstract GDSII file in Virage layers v Generate a GDSII file with only the power ring and external sign v Generate a Cadence PLEF description for the memory v Combined Datasheet for all PYT corners vi ALF Model v fastscan file v Fastscan Model v Tetramax Initialization File v memBIST Model v memBIST Config file v Verilog RTL Model The top portion of the tab lists front end views the datasheet views are in the middle and the backend views are along the bottom Buttons at the bottom of the dialog enable you to change the settings for all the views you have access to with one click The All Off button turns off the generation of all the views active on the Views tab while All On turns on th
18. n Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Page5 e There is a Views Area that shows an output view for a component in the Project Tree Highlighting an output view for a component in the Project Tree and double clicking the mouse displays the file contents in the Views area Use the button if you want to show the Views area only and the LJ button to show Messages and Views windows concurrently e There is a Messages Area that displays all information messages that occur when you apply a command to a project Use the b amp l button if you want to show the Messages area only and the LJ button to show Messages and Views windows concurrently 2 1 Working with Memory Components Integrator Online application provides you with an easy way to work with memory components Only a few successive steps are required to create a new component and generate an output view for it To create a new component you simply select a compiler and start configuring the component by supplying necessary parameters and data Information on different memory parameters and data that you may need to supply during component configuration stage is available in section 2 1 1 Creating a New Component Integrator Online also enables you to create components based on existing cfg files that contain component configuration See section 2 1 2 Importing a Component for more details on how you impo
19. ogic Corp Embed It NOVeA and AEON are registered trademarks of Virage Logic Corp All rights reserved All other product and company names used in this document may be trademarks of their respective owners Virage Logic Corporation reserves the right to make changes to any products or services herein at any time without notice Virage Logic does not assume any responsibility or liability arising out of the application or use of any product or service described herein except as expressly agreed to in writing by Virage Logic nor does the purchase lease or use of a product or service from Virage Logic Corporation convey a license under any patent rights copyright trademark rights or any other intellectual property rights of Virage Logic or of third parties The information furnished in this manual is believed to be accurate at the time of printing Virage Logic Corporation reserves the right to make changes to any products or services herein at any time without notice Virage Logic does not assume any responsibility or liability arising out of the application or use of any product or service described herein except as expressly agreed to in writing by Virage Logic nor does the purchase lease or use of a product or service from Virage Logic Corporation convey a license under any patent rights copyright trademark right or any other intellectual property rights of Virage Logic or third parties THIS PUBLICATION IS PROVIDED AS IS WITHOUT
20. ompilers only Click on the node handle beside the name of compiler to display the sub categories of available compilers The tree of sub categories is based on compiler identification information including target foundry Foundry process geometry Process compiler name Compiler and compiler revision level Revision Once you have navigated down to selecting a specific compiler the Compiler Info area on the right hand side of the Configure Compiler dialog displays all the identification information for the compiler Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Page 7 You can also check the Choose by Compiler Name checkbox to list the compilers by name After you choose the required compiler select the Configure button to open the Configure Component dialog shown in Figure 2 4 Configure Component Window below Figure 2 4 Configure Component Window x General Advanced Compiler Information Compiler Chartered Semiconductor 0 13um G Salicide Standard Vt ASAP Dual Port High Density SRAM 512K Sync A05 Process Voltage Vv Temp C Number of Words T 25 Typical PALi B 1 32 40 Best Bits Inward W 1 08 125 Worst Column Mux Option Frequency MHz Memory Name v Automatic Memory Naming New Defaults Range 16 8k Ok Apply Cancel The Configure Component dialog can look sl
21. rds 8 O Operating Points 17 operating points 9 Operating Voltage V 9 P Parameters to control instance 11 Performing Tasks 13 Process Condition 9 Process condition 9 PVT conditions 9 PVT window 9 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate 21 R Read ports 8 Redundancy enable 9 Running Integrator Online Software 1 S Server host name and port number 15 Signal Metal 9 Status Area 9 11 12 U User login name 15 User Name 3 W Working with Components 6 Write ports 8 22 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate
22. rt a component After you configure your component you must generate it to create an output view for it See Generating a Component on page 13 The component creation process involves a few formal procedures that Integrator Online accomplishes automatically When you generate a component the tool automatically sets up an initial directory structure for the component on the server When you attempt to download the files for the generated component the initial directory structure is preserved See Downloading the Generated Files on page 14 At any time during your work you can consult this User s Manual for assistance by selecting Help gt User s Manual from the menu option or by pressing the F1 key on your keyboard Page 6 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate 2 1 1 Creating a New Component Selecting Component gt New menu option m opens the Select Compiler dialog shown in Figure 2 3 Select Compiler Window below Figure 2 3 Select Compiler Window x A Chartered Semiconductor Compiler Information Chartered IBM Dongbu Anam G Flex fab IBM G Silterra smic A Tower Semiconductor TSMC amp A UMC _ Choose by Compiler Name Close By default the compilers added to your account by the Administrator are listed by type of compiler Integrator Online allows to configure memory and ROM c
23. running script the Abort button can be used All other actions will be unavailable while the script runs 2 1 4 Downloading the Generated Files After you generate a component its output files stay residing on the server until you download the files Once you decide to download them you have three options to choose from All Component and View Note that you downloadable are only the generated components with green indicator light in the Projrcet Tree If you want to download all components and their output views that are in the Project Tree simply use the Project gt Download gt All menu option In the Save As dialog browse over to or create a directory where you want your files to be downloaded to and press the Save As button This will start the process of downloading all components into the download directory you defined While the files are downloaded only the Abort button is active in the Download dialog Use the Abort button if you want to stop downloading the files and the Close button to close the Download dialog when the download is complete If you want to download a component simply highlight its name in the Project Tree and select Project gt Download gt Component menu option In the Save As dialog browse over to or create a directory where you want the component to be downloaded to and press the Save As button This will start the process of downloading the selected component into the download directory you defined W
24. s version runs in a separate window from your browser Also note that you must have JRE 1 4 2 and Sun s Java Web Start JWS software installed before you run the client side version of Integrator Online In section 1 2 What You Need to Run Integrator Online of this guide there is information on how to obtain the necessary software Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Page3 The next time you use the client side Java version of Integrator Online it will launch from the copy that was downloaded and installed the first time if Integrator Online is not updated on the server and it will start up much faster Figure 2 1 Login Window 4 Integrator Online Project Component Run Help rr KADA bjm Please login Server PRODUCTS User RAGE SOLUTIONS IOL Key In the Login Window enter your user name in the field marked User and your IOL Key in the field marked IOL Key and press Login Page 4 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Once you have successfully logged in the Main window shown in Figure 2 2 Main Window appears Menubar a Integrator Online user Figure 2 2 Main Window Toolbar The Views Area Bia gt Q E hsss2_64x4cm4bkt hsss2_64x4cm4bk1 cfg Configuration r
25. s window disappears after you confirm that you want to exit Integrator Online Page 16 Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Chapter 3 Integrator Online Command Line Access Integrator Online command line client is implemented as a single jar Java archive file Application contacts the server passes the memory configuration initiates generation of the memory instance and then downloads all output files to the client host If the process fails it exits with a non zero code and the corresponding error message is displayed The usage of the Integrator command line is java jar rvmc jar u hostname port l loginname p password c configuration_file d destination k f h Table 3 1 Command Line Options below describes the purpose for each of the options Table 3 1 Command Line Options Option Purpose u hostname port_number Server host name and port number login_name User login name p IOL key IOL key If not specified user will be prompted to enter it in the interactive mode If the server is installed with the p option disabled you will get an error when you use the command line client c configuration_file_name The memory configuration to generate RVMC can accept more than one configuration file per session Use the c option to specify the path to the directory that contains the cfg file s java jar rvmc jar u iol server com 1 U
26. serName c path to cfg_files RVMC will recursively search and process all cfg files in the specified directory within a single session d destination Directory name to download instance into The default is the current working directory k Keep a copy of the generated instance on the server Copyright 1998 2011 Virage Logic Corporation Proprietary Information Do Not Duplicate Page 17 Option Purpose f Overwrite if there is an instance with the requested name on the server h Print usage information and exit The exit codes are 0 Success 1 Connection error 2 Access denied 3 Configuration file not found 4 Parameter check error 5 Generation Failed 6 Destination directory does not exist 7 Command line parsing error 8 Unexpected errors Note that if your network communicates with the Internet via a proxy server Integrator Online allows using Java keys for specifying the proxy server name and proxy port number in the commands The format for such commands can have the following view java Dhttp proxyHost your_proxy_server_name Dhttp proxyPort your_proxy_port_number jar rvmc jar u iol2 viragelogic com etc where your_proxy server _name and your_proxy port _number must be replaced with the actual values for your proxy server name and proxy port number and the etc means all other command line options to use If a termination signal is detected RVMC closes current conne
Download Pdf Manuals
Related Search
Related Contents
Sección K - CIDBIMENA Serie XL Manual del usuario EMU 3.x Manual - Omni Technology Solutions Inc. repertoire ferroviaire - Bureau économique et Commerciale de la DS-9600NI-I8 (manual). JVC UX-V330R User's Manual 101210042 Manual Instruccions CH420L Rev 0.PUB PRODUIT : TITESEAL PUNCTURE SEAL — OBTURATEUR Mode d`emploi pour le relevé des compteurs Copyright © All rights reserved.
Failed to retrieve file