Home

SA-ATM-1 - Access Technologies International

image

Contents

1. used Black Red White Gray Orange Green SA ATM 1 Leader in State of the Art Technology for Integrated Security 4 Warranty and Service The following warranty and service information applies only to the United States of America For the information in other countries please contact your local distributor To obtain in or out of warranty service please prepay shipment and return the unit to the appropriate facility listed below Access Technologies International Inc 840 North Old World Third Street Milwaukee WI 53203 Tel 414 289 3121 Fax 414 289 3129 Email ati atiaccess com Web site www atiaccess com OUTSIDE OF THE UNITED STATES Visit our Web site www atiaccess com for your local representative Please use the original container or pack the unit s in a sturdy carton with sufficient packing to prevent damage include the following information 1 A proof of purchase indicating model number and date of purchase 2 Bill to address 3 Ship to address 4 Number and description of units shipped 5 Name and telephone number of person to contact 6 Reason for return and description of the problem NOTE Damage occurring during shipment is deemed the responsibility of the carrier and claims should be made directly to the carrier User Manual 9 SA ATM 1
2. ation Diagram User Manual su SA ATM 1 Leader in State of the Art Technology for Integrated Security CONTROLLER TRANS PORNMER TRA amp ANSFCOAMER acram Tic ODOR LOR fs SENSOR INPUT MORA OPEN SENSOR FOR ALITCHERELCX E Cor ALA 1E 2 2 Controller Specifications e Card Reader Construction Anodized Aluminum Bezel Stainless Steel Casing e Controller Construction Powder Coated Galvanized Steel e Power Supply Output 12 V 500mA Input 120 VAC 60 HZ 9W e Operating Environment Temperature 20 to 140 F Humidity 5 95 non condensing e Output Relay Form C dry contact 120V 3A e Shipping Weight 10 lbs 2 3 Installation Diagram User Manual ss SA ATM 1 Leader in State of the Art Technology for Integrated Security T E sensor Input OC Transformer Card reader GEM LED FA GEM ELE REO Eme Dno Gil Hc MO C MC MO cC Locking Device Power Supply Release Devices Relay Switch Power Switch 2 4 SA ATM 1 Enclosure Dimensions User Manual 6 SA ATM 1 Leader in State of the Art Technology for Integrated Security 3 SA ATM 1 Insertion Reader wiring diagram User Manual a SA ATM 1 Leader in State of the Art Technology for Integrated Security OO 1 i 1 8 Height of cad reader cout at LE Weckth of cand sseder cut aot 1 1 User Manual 8 Blue not being Ground BV Data Strobe Red LED Green LED SYN GEN
3. l Ja SA ATM 1 Leader in State of the Art Technology for Integrated Security Contents e Introduction 1 1 Features 1 2 Equipment Options e SA ATM 1 Controller 2 1 Configuration Diagram 2 2 Controller Specifications 2 3 Installation Diagram 2 4 Enclosure Dimensions e Insertion Reader Wiring Diagram e Warranty and Service 1 Introduction User Manual e SA ATM 1 Leader in State of the Art Technology for Integrated Security The SA ATM 1 Access Control System provides state of the art magnetic stripe access control for your ATM Vestibule The SA ATM 1 Controller is an insertion magnetic stripe card access control system This unit supports l insertion magnetic stripe card reader with 1 relay output and 1 input The SA ATM 1 also supports Synergistics card reader The SA ATM 1I provides Egress and Auto Relock features 1 1 Standard Features e Magnetic Stripe Track Two Insert Card Reader with Tri Color LED e Two Output Relay Contacts for Door Release Control e Auto Relock Input Point for door sensor kit e Test Button for Output Relay e Card Reader Override Switch e Egress Input Option e Door Lock Open Time interval 3 13 seconds 1 2 Equipment Options e Door Sensor Kit e Piezo Buzzer e Card Insert Graphic Instruction Sticker e Surge Protector or Uninterruptible Power Supply e Post Surface Mount Card Reader Enclosure e Card Reader Adapter Spacer Plates 2 SA ATM 1 Controller 2 1 Configur
4. scoot TEGHNOLOGIES INTERNATIONAL SA ATM 1 INSTALLATION USER MANUAL ENGINEERED SYSTEMS Leader in State of the Art Technology for Integrated Security Copyright and Trademarks Copyright O 2004 2007 Access Technologies International Inc All rights reserved Printed in United States No part of this book may be used or reproduced or stored in any form by any means without the written consent of Access Technologies International Inc The information in this book is subject to change without notice This book is provided as is without warranty of any kind either express or implied including but not limited to performance merchant ability or fitness for any particular purpose Neither Access Technologies International Inc nor its dealers or distributors shall be liable to any person or entity with respect to any liability loss or damage caused or alleged to have been caused directly or indirectly by this information StarAccess is the registered trademark of Access Technologies International Inc Any other trademarks or service marks belong to their respective companies Use of a term in this book should not be regarded as affecting the validity of any trademark or service mark ACCESS TECHNOLOGIES INTL INC 840 North Old World Third Street Suite 600 Milwaukee Wisconsin 53203 USA Tel 414 289 3121 Fax 414 289 3129 Email ati O atiaccess com WWW www atiaccess com January 1 2004 User Manua

Download Pdf Manuals

image

Related Search

Related Contents

31.12.2014-V1.6  Mode d`emploi - Alert Gasoil  SONDERBEILAGE  DNA-STP-SYNC-1G Synchronization and Screw Terminal Panel  be.ez 13" LA garde robe Red Kiss  ピストン分配器、計量ユニット LS-0005-JA  Descarregar  Samsung C260 User Manual  ou acheter les jetons pour faire la vidange  Philips 107T Blender User Manual  

Copyright © All rights reserved.
Failed to retrieve file