Home

BioBridge

image

Contents

1. Name Description Location Model E MA 500 MA500 MA sigm Multi MA SIGMA Multi C MAVP MA VP Dual Biometric Device Wiegand Profiles User Policy User Distribution Group User Authentication Mode Operator Role Clients Scheduled Reports Card Template Card Encoding Log Event Log Exception Log Page 8 BioBridge Quick Setup Guide BioBridge System Configuration The last step in the process is to configure BioBridge specifications to C CURE 9000 e From Administration select System Configuration e Select the BioBridge Tab in System Configuration S Administration Zy User Management 8 MSO Identification Bl Onsite Offsite A Access Logs A Reports System Configuration Biometric Device Profile Contactless Keys Communications Engi System Functionality Gateways Connector Service BioBridge Privacy Mode Biometric Device MorphoManager BioBridge Settings System None os Configure connection Wiegand Profile User Not Found Disable Wiegand Profiles User Policy User Distribution Group Access Level Mode User Authentication Manual Mode Caching Engine Refresh Interval min 5 Operator Role Synchronization Engine Refresh Interval ms 100 Chents Enable Forced User Policy E ID Only Scheduled Reports Card Template sli User Distribution Group Card Encoding Log Event Log Exception Log SE Syste
2. using the currently set filter conditions Page 13 BioBridge Quick Setup Guide Search Field The Search Field can be used to find individual users quickly and or to migrate users from C CURE 9000 to the BioBridge Enrollment Client without waiting for a cache refresh Data Grid The data shown in the data grid is a combination of your system and MorphoManager Only users that exist in your system will be shown A MorphoManager user does not exist until the user is enrolled By default pagination is set for the first 25 BioBridge users to be shown Operators may change the pagination to 25 50 100 amp 250 The data grid will have the following columns e Card Number e First name e Middle name e Last name e Clearances All of the Access Level groups that your user is a member of in your system Comma separated values e Enrollments None Finger Finger amp 3D Face 3D Face Derived from linked MorphoManager User e Disabled A value of either True or False will be present Details Logs Finger Biometrics amp Connected to tcp dwest identityone net 42100 Logged in as Administrator Sys Site ID 9A53 7B91 7245 4A1B BD1A CC11 5512 E72D Log Out _ Change Password Enrolled user will show their MorphoManager details in the Show Details panel below the data grid This area will be blank if the user has not been enrolled Page 14
3. you choose for your users must marry to the one you utilize for your biometric access devices set in the Biometric Device Profile section of this guide The default User Policy will be set to utilize an authentication mode of Biometric 1 Many To utilize another authentication mode such as encoding smartcards additional User Policies can be created Please reference the MorphoManager User Manual for more detail on all the various properties that can be assigned to a User Policy including Wiegand Profile Finger Biometric Enrollment Minimum Fingers Access Modes and User Authentication Modes Page 7 BioBridge Quick Setup Guide User Distribution Groups User Distribution Groups are designed to distribute users onto groups of MA readers or MorphoManager Clients In order to be utilized the user must be in a User Policy that has its Access Mode set to Per User Then the User Distribution Groups will be selectable when creating or editing a user e From Administration tab select User Distribution Group e Click Add button to create a new User Distribution Group Below is the screenshot where group will only be placing users on one of the three devices installed on the system S Administration User Management S MSO Identification B Onsite Offsite AP Access Logs A Reports Adding User Distribution Group 5 Operator Select Biometric Devices A Select Al 4 Clear All Biometric Device Profile
4. MorphoManager BioBridge Software House C CURE 9000 Quick Start Guide Sy SAFRAN Morpho BioBridge Quick Setup Guide Table of Contents TUE OWT IO Bila cies se Ee GE RE AG GR Ge ee EG GE ee 3 dle eel AA EE N EE EE RE ET EE ER EE EE EE EE 3 SCENE UP BIGBHOAEES SR Ge N de GE N ee ES NE 4 WA TSS able Polla SEE EG De ee Ee ee N De es Ge De GER N Di 4 Biometrie DEVICE POM Orsi EE SR DE Ee EE N E E Ge EE ee Ee Ge N Ge EG 5 Biometrie DEVICE S ENE EE EE EN AO N N eerii 6 Lisar PONG Y ie OE sud cae Ee EE T ee Ge Ge ee Ge Ee E AG 7 USEF Distribution GO UP GE GE DEE GE AG GE De GE DE ee N Ge EE EG Di 8 BioBtide System EConlieuratie see GEN SEE LR GR GE GR Ge N Ge Do Ge Ge EG Ge EEEE GE WE GE De 9 Using the BioBridee ENFOME CE ES ee a DR Ge arn 12 ele oe A EE RE OE MT EE OE EE OE OE N ueamoN 12 pel EERDER ER ELE HE RO AL OR OE HORE OE OE TO EE HA 12 See RE RE EO N EE AE N N EE EEN EE 13 Encode Cal di ER EE DER DE EG GE ED Ge ED DR EG EE RE Ge N EG DE EE EG Ee GN ee 13 alie EE EE OE EE Ee 13 PRET SS Borne oa SEED OE N ES ED AE EE NE AE N EG ND N ED N NE EE ie 13 Search Field esse DR E nce RE EE OE EG EE OE Oe EA EO 14 Data GNU se DE EE EE N GE E Ee GE ee EG Ge EO toe ee 14 Page 2 BioBridge Quick Setup Guide Introduction BioBridge is an enrollment and synchronization middleware that overlays enrollment and demographic synchronization between MorphoManager and third party data sources The infrastructure is extensible and supports interfa
5. MorphoManager User Distribution Groups 1 Automatic This mode will automatically match Access Level groups from C CURE 9000 to the ones created in MorphoManage User Distribution Group if they have the same naming convention System Configuration Time amp Attendance Contactless Keys Engine System Functionality Automatic Log Management Gateways BioBridge Privacy Mode MorphoManager BioBridge Settings Wiegand Profile Card Keypad Format 26 bit Wiegand User Not Found In Automatic mode the groupings from your system and the User Distribution Groups created in MorphoManager with the same name will match up Those with no match would be left blank Access Level Mode Gees Caching Engine Refresh Interval min 5 Synchronization Engine Refresh Interval ms Enable Forced User Policy Default Access Level User Distribution Group Access Level 1 Access Level 2 Page 10 BioBridge Quick Setup Guide 2 Manual If the Access Level grouping names of C CURE 9000 and the User Distribution Group s created in MorphoManager are not the same then selecting which C CURE 9000 Access Level maps to which MorphoManager User Distribution Group can be done manually in the User Policy Mappings System Configuration Time amp Attendance Automatic Log Management MorphoManager BioBridge Settings System Wiegand Profile Card Keypad Format User Not Found Acces
6. cing to multiple third party systems one at a time by the implementation of an interface BioBridge is not dependent on the underlying technology platform required for integration Support Please contact your installer for additional support Page 3 BioBridge Quick Setup Guide Setting up BioBridge The following areas of MorphoManager will need to be configured as part of the Software House C Cure 9000 BioBridge setup Wiegand Profiles Biometric Device Profiles Biometric Device User Policy User Distribution Group BioBridge System Configuration ee Wiegand Profiles Wiegand Profiles define what information is output over the Wiegand Out interface of the Morpho Biometric Devices when a user is identified This is most typically used in conjunction with an Access Control System e From Administration tab select Wiegand Profile e Click Add button to create a custom Wiegand profile The Wiegand formatting used can vary from system to system but some common formats are listed below Bl Onsite Offsite A Access Logs A Reports Items Wiegand Profiles D amp x 2 PEN t Export 5 Operator Add Edit Delete Refresh bal Expor Biometric Device Name Description MA2G MASG Profile i Automatically generated random 64 bit Interpreted Interpreted Biometric Device CASI RUSCO 40 bit 19 bit Facility 19 bit Badge HID Corporate 1000 HID Corporate 1000 Wiegand Profiles ISO IEC 14443 CSN 32 bit 32 bit Card Seria
7. l Number ISO IEC 14443 CSN 56 bit 56 bit Card Serial Number N User Policy ISO IEC 14443 CSN 64 Bit 64 bit Card Serial Number User Distribution i Kastle 32 bit ae ix 56 bi 54 bit User ID User Authentication 8 bit facility 48 bit card number 8 bit issue code Mod s 8 bit Site 16 bit User code Operator Role U clients Scheduled Reports Card Template Card Encoding Log 0 Event Log Exception Log Connected to tcp localhost 42100 Logged in as Administrator System Adminis Site ID 3887 A70D 9580 42D7 8757 DC24 1AA7 16F0 2 Log Out p Change Password The actual setting of the Wiegand Profile from this list will be done at the User Group and Biometric Device Profile Level Please refer to those sections for further details Page 4 BioBridge Quick Setup Guide Biometric Device Profile The Biometric Device Profile will define common settings and parameters for one or more biometric devices This profile can be applied when adding units into the system from the Biometric Device section of Administration e From Administration tab select Biometric Device Profile e Click Add button to create a new Biometric Device Profile B Administration zy User Management MSO Identification B Onsite Offsite AP Access Logs a Reports Adding Biometric Device Profile j Operator Enter details for the Biometric Device Profile Biometric Device _ Profile nS Description Biometric Device Configuration Mode Wiega
8. m Configuration e System From the System drop down menu choose C CURE 9000 and click the Configure connection button A BioBridge connection box window will pop up Fill in all the required fields and click OK Please enber Hie address of He C Cure 9000 SOL database T ure 3000 Serverr 10 10 3 LS Logon detasils Please enter the username and password used te connect to the CAcure 3000 SQL Server database Lisernanrnc admina tr ater Passord See ee ee Partition If your Colure D000 application uses partitions and you wiah to use a angle Particular one you must use the Load Partitions button and select the partton you wish to use Otherwise MorphomManager will use Al Farttons by default Parttian te Line All Partana Lee Fear bebcoris Loa ocan e Page 9 BioBridge Quick Setup Guide e Wiegand Profile Select the Wiegand format in use from the drop down menu e User Not Found Decide how MorphoManager should handle any enrolled user if they are no longer found in C CURE 9000 This setting determines what action MorphoManager should take when a previously enrolled user is not found in the in C CURE 9000 1 Disable The user will remain in MorphoManager but be in a disabled state They will NOT be able to gain access through any Biometric Device 2 Delete The user will be purged from MorphoManager e Access Level Mode This setting determines how MorphoManager should map C CURE 9000 users into
9. nd Profile Automaticall ted random 64 bit Wiegand Profiles me a n Realtime logging enabled User Policy Log retrieval interval seconds User Distribution Language Group Display name encoding code page Western Europe Default ISO 8859 1 Applicable to MA500 series only EK Duplicate check on biometrics MA 100 MA J MA 500 MA VP and MA Sigma only Only applicable to new user adds or rebuild operations Operator Role MorphoAccess heartbeat interval seconds Clients Scheduled Reports Card Template Card Encoding Log Event Log Exception Log In order to create the most basic profile utilizing biometrics stored on the devices that can be used simply give the profile a name and click Finish Please reference the MorphoManager User Manual for more detail on all the various properties that can be assigned to a Biometric Device Profile including the use of smartcards If you plan on using a Wiegand Profile you will need to set the Wiegand Profile for the Biometric Device s here The Wiegand Profile you choose for your devices must marry to the one being utilized for your users set in the User Group section of this guide Page 5 BioBridge Quick Setup Guide Biometric Device s A Biometric Device is the device used to verify users and allow access to doors They record a log of every attempt to gain access MorphoManager is used to manage user s access to Biometric Devices e From Administration
10. rance 1 Clearance2 ExpiredCard Clearance 1 Enroll Enroll will start the enrollment of the selected user The enrollment process will be derived from the standard MorphoManager user add edit wizard with the following pages For details on the enrollment process please see the User Management section of the MorphoManager User Manual e Authentication Type Only if more than one mode is configured e 3D Face Selection e 3D Face Enrollment e Finger Selection e Finger Enrollment Page 12 BioBridge Quick Setup Guide If a card based authentication method is configured the operator will be prompted if they want to encode a card Edit Opens the already enrolled user details for viewing or editing Encode Card Encode card will display an animation of the card being presented to a SDI 011 and wait for the card encoding to complete or be cancelled Filter User Details User Wiegand values First Name Card Number Middle Name Last Name Card Number Enabled Any Enabled Disabled Clearances iw Select All T Clear All E Clearancel O Clearance Sort By Primary Card Number Ascending ki Secondary Last Name Ascending Tertiary First Name Ascending r Filter will show a popup inline form that allows filtering on the following items e First Name e Middle Name e Last Name e Card Number e Enabled Disabled e Clearances Refresh Refresh will update the data currently being shown
11. s Level Mode ss In Manual mode you can select whatever Caching Engine Refresh Interval min MonphoManager User Distibution Group you want Synchronization Engine Refresh Interval ms DI to match to your system group Enable Forced User Policy User Policy Mappings Access Level Access Level 1 Access Level 2 e Make sure to click SAVE when finished Page 11 BioBridge Quick Setup Guide Using the BioBridge Enrollment Client After configuring BioBridge you will now utilize the BioBridge Enrollment Client This client will check if BioBridge Integration has been enabled and configured If it is has not the application will display the message BioBridge integration has not been enabled and configured and you will need to go back to MorphoManager Administration System Configuration BioBridge to configure it properly If BioBridge integration is configured the application will display a user management screen The screen will consist of a toolbar and a data grid Toolbar The toolbar will have the following items e Enroll e Edit e Encode Card e Filter e Refresh e Search Field MorphoManager BioBridge Clien User Management Showing users 1 8 of 8 filtered results 8 total users Enroll Edit Encode Card StolenCard Clearance 1 LostCard Clearance1 NotActiveYetCard Clearance1 DisabledPersonnel Clearance1 Regular Clearance 1 DisabledCard Clearance1 2Clearances Clea
12. scription Hardware Type MA SIGMA Multi Clients Serial Number 1431SMS0000243 Firmware version 1 4 2 Scheduled Reports Hostname VIP Address 10 10 214 11 11010 User Slots 0 3000 Card Template Time Zone UTC 05 00 Eastern Time US Canada Device Status Online Card Encoding Log Event Log Exception Log Page 6 BioBridge Quick Setup Guide User Policy User polices are used to apply access rights and rules to all members of the group To Configure BioBridge MorphoManager s UserPolicy with an Access Mode Per User must be selected This will create User Distribution Groups groups of Biometric Devices that can place the enrolled user into specific devices e From Administration tab select User Policy e Click Add button to create a new User Policy Enter the details for this User Policy Name Description 7 Access Mode are E Allow MA 500 database selection during user enrollment Time Mask Mode 24 Hours 7 Days a Week Extended User Details E Display extended user details Wiegand Profile User Authentication Mode Identifier Only Finger Biometric Enrollment Minimum Fingers r r Preferred Finger One Left Index Finger Preferred Finger Two Preferred Duress Finger Left Middle Finger z If you plan on using a Wiegand Profile you will need to set it here in order for the users enrolled in this User Policy to have a particular Wiegand Profile The Wiegand Profile
13. tab select Biometric Device e Click Add button to create a new Biometric Device e Enter the details for the device including the Hardware Family the device falls into the IP address and the Biometric Device Profile Editing Biometric Device 5 Operator Enter the details for this Biometric Device A sigm Multi Biometric Device Profile Biometric Device Asset ID Export Value User Policy Time Zone UTC 05 00 Eastern Time US amp Canada Hardware Family MA Sigma Wiegand Profiles User Distribution Group Hostname VIP Address 10 10 214 11 User Authentication Port 11010 Mode Biometric Device Profile Default Operator Role um of Include in Time amp Attendance Exports Change User Onsite Offsite Status Clients Onsite Key No Key Scheduled Reports Offsite Key No Key Card Template Card Encoding Log Event Log Exception Log e Once the required details are entered click Finish Below is a screenshot of how the Biometric Device Screen looks after the configuration and the devices are online Items Biometric Device 2 o S 9 gt Operater GetLogs SetDate Time Rebuild Set Offline Biometric Device Profile Description MA sigm Multi Default v Online Biometric Device Wiegand Profiles User Policy User Distribution Group Details Logs Queued Tasks 0 Failed Tasks 0 Hide Details User Authentication Mode MA sigm Multi Operator Role De

Download Pdf Manuals

image

Related Search

BioBridge biobridges biobridge global biobridge login biobridge global san antonio tx biobridge global careers biobridge cardiology portal biobridges llc biobridge partners biobridge global address biobridge lymphedema biobridge global advanced therapies biobridge cardiology portal login biobridges careers biobridge san antonio biobridges morrisville nc biobridge san antonio tx

Related Contents

Benq GL2040M  ORiNOCO - ソルテック・ソリューションデザイン株式会社  VDS-601P・751P  mark - SUGARfx  Manual de instrucciones para la instalación de luces LED  TCC-1800K2  HERMA Security labels A4 63.5x29.6 mm white extra strong adhesion film matt 675 pcs.  Scout v1.3 User`s Guide (Android)  mode d`emploi de MILKSTAPH, test de détection de staphylocoques  Sony CMT-HX7BT Speaker System User Manual  