Home
DA-SDI-NRC - AV
Contents
1. DA SDI NRC SDI Distribution Amplifier Non reclocking version Rev 3 5 D pe 0 3 T De D a ban 0 z A wa a e 3 DA SDI NRC Rev 3 Network Electronics ASA Thorgya P O Box 1020 N 3204 Sandefjord Norway Phone 47 33 48 99 99 Fax 47 33 48 99 98 Email support network electronics com www network electronics com Support Phone 47 90 60 99 99 Revision history Current revision of this document is the uppermost in the table below Rev Repl Date Sign Change description 3 2 2007 10 25 AS New front page 2 1 2007 10 05 AS Added Materials Declaration and EFUP 1 0 2007 01 29 SHH Updated manual to DA SDI mkll design with 8 outputs 0 A 2005 04 06 First official release no changes from Rev A A 2004 01 20 Preliminary version network electronics com 2 DA SDI NRC Rev 3 Contents Revisio TIES LOE Paneer deren breenei nennen 2 1 Product OVERVIEW ten ars noice tescoteans vatten beard aten arenden Benham 4 2 PECHEALUOM EA E avan hebk biken dhadertndaelee 5 3 FOLIA COMPO URAUON vereren eed 6 3 l Configuration EXADDISS srne re a E orate 7 A Connector Module nerven dies ie ivesi trsni aker aona eA N ES keune EEEE EEE seen Eea 8 4 1 Mounting the connector mOdules senesta 9 5 Mod le SCIRUS sens eenander end Asten 10 5 1 GPI ALARM Module Status Outputs i lt 5 lt lt 5 0scdecoieon oa eeuesesucsds veranderde van aken 10 5 2 Fron
2. 103 2 1996 Generic Immunity Standard network electronics com 13 DA SDI NRC Rev 3 Product Warranty The warranty terms and conditions for the product s covered by this manual follow the General Sales Conditions by Network Electronics ASA These conditions are available on the company web site of Network Electronics ASA www network electronics com network electronics com 14 DA SDI NRC Rev 3 Appendix A Materials declaration and recycling information A 1 Materials declaration For product sold into China after 1st March 2007 we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products In the first stage of this legislation content of six hazardous materials has to be declared The table below shows the required information Toxic or hazardous substances and elements RER a K i ADE SRK SR AR Part Name Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Pb Hg Cd Chromium biphenyls diphenyl ethers Cr V1 PBB PBDE DA SDI NRC X O O O O O O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 A 2 Environmentally frien
3. ED Green LED No light Status Module is faulty Module is OK Module has Module power is OK no power Rate NA NA NA Always LOS Loss of signal LOS detection de Input signal present No input signal activated EQM off LOCK NA NA NA Always network electronics com 11 DA SDI NRC Rev 3 General environmental requirements for Network Electronics equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions Operating room temperature range 0 C to 40 C Operating relative humidity range lt 90 non condensing 2 The equipment will operate without damage under the following environmental conditions Temperature range 10 C to 50 C Relative humidity range lt 95 non condensing 3 Electromagnetic compatibility conditions Emissions EN 55103 1 Directive 89 336 EEC Immunity EN 55103 2 Directive 89 336 EEC network electronics com 12 DA SDI NRC Rev 3 Certificate of Conformity Network Electronics ASA Company Registration Number N 3204 Sandefjord NO 976 584 201 MVA Norway Declares under sole responsibility that the product Product name DA SDI NRC Product description SDI Distribution Amplifier Non Reclocking version To which this declaration relates are of Norwegian origin and are in conformity with the following standards EN 55103 1 1996 Generic Emissions Standard EN 55
4. ation on the card status The functions of the GPI and the LED s are described in sections 5 1 and 5 2 The GYDA controller is described in a separate user manual 5 1 GPI ALARM Module Status Outputs These outputs can be used for wiring up alarms for third party control systems The GPI outputs are open collector outputs sinking to ground when an alarm is triggered The GPI connector is shown in Figure 7 Electrical Maximums for GPI outputs Max current 100mA Max voltage 30V DA SDI NRC module GPI pinning Brown _ Pair4 Greeny __ Blue Pair3 N Pair1 ar Orange a Pair 2 Figure 7 GPI Outlet Signal Name Pin Mode Status General error status for the module Pin 1 Open Collector Rate NA Pin 2 Open Collector LOS Los Of Signal Pin 3 Open Collector LOCK NA Pin 4 Open Collector Ground 0 volt pin Pin 8 OV network electronics com 10 DA SDI NRC 5 2 Front Panel Status Monitoring The status of the module can be easily monitored visually by the LED s at the front of the module The LED s are visible through the front panel as shown in Figure 8 below Text not printed on the front panel Figure 8 Front panel indicator overview for DA SDI NRC Rev 3 The DA SDI NRC has 4 LED s each showing a status corresponding to the GPI pinning The position of the different LED s is shown in Figure 8 Diode state Red LED Yellow L
5. dly use period The manual must include a statement of the environmentally friendly use period This is defined as the period of normal use before any hazardous material is released to the environment The guidance on how the EFUP is to be calculated is not finalised at the time of writing See http www aeanet org GovernmentAffairs qfLeO pAaZXaMxqGjSFbEidSdPNtpT pdf for an unofficial translation of the draft guidance For our own products Network Electronics has chosen to use the 50 year figure recommended in this draft regulation Network Electronics suggests the following statement on An Environmentally Friendly Use Period EFUP setting out normal use EFUP is the time the product can be used in normal service life without leaking the hazardous materials We expect the normal use environment to be in an equipment room at controlled temperature range 0 C 40 C with moderate humidity lt 90 non condensing and clean air not subject to vibration or shock Further a statement on any hazardous material content for instance for a product that uses some tin lead solders Where a product contains potentially hazardous materials this is indicated on the product by the appropriate symbol containing the EFUP The hazardous material content is limited to lead Pb in some solders This is extremely stable in normal use and the EFUP is taken as 50 years by comparison with the EFUP given for Digital Exchange Switching Platfo
6. drawing below with the DIP switch to the upper left position Rev 3 C6 E17 O RSL R38 aj D Spee u 8 c75 p 8 Sht n c3 C7 aa c18 Reo FE E l EE F j R76 c g ces zp Dt R3 g a B ecn BO R4 P06 3 xt 2 ijle st z SB as a R56 7 Q92 G6 98 Le aL me aed D2 R5 c2 Rg Roz B Ea g R21 GEB pe Ros Rae ice R 1c11 erai a z E oe P Da Rg ot a P7 i 4125 c82 F1 RAST eee ee Ez s LABEA ZEER c11 ro RE od D4 2 R2 R61 aa viz EE a 4 Figure 2 DA SDI NRC board layout DIP switch configuration must be set according to the table below Switch Label Function DIP OFF Function DIP ON Comment 1 ARB NA NA NA 2 EQM Equaliser forced Automatic muting of equaliser Input mute not to mute when signal strength is too low 3 RCL NA NA NA 4 EQ Cable equaliser Cable equaliser ON Equaliser mode Bypass 5 ASI NA NA NA 6 SLL NA NA NA 7 BWL NA NA NA 8 OVR GYDA control Override GYDA control Select GYDA Config with GYDA Config with DIP switch config mode All DIP switches are off when pointing towards the release handle network electronics com 6 DA SDI NRC Rev 3 3 1 Configuration Examples Typical configurations for DA SDI NRC OVR 8 Figure 4 AES3id compatible and Low Bit rate without equalisation network electronics com 7 DA SDI NRC Rev 3 4 Connector module The DA SDI NRC has two dedicated connector module DA SDI C1 and DA SDI C2 These modules are mounted at th
7. e rear of the sub rack The modules are shown in Figure 5 and Figure 6 Figure 5 Overview of the DA SDI C1 connector module The electrical input signal is connected to the IN BNC and the electrical outputs are connected to the O1 to O6 BNC s Please note that all 6 outputs are non inverted network electronics com 8 DA SDI NRC Rev 3 On DA SDI C2 the electrical input signal is connected to the IN BNC and the electrical outputs are connected to the O1 to O8 BNC s Please note that outputs 1 to 6 are non inverted and suitable for DVB ASI while outputs 7 and 8 are inverting and cannot be used for DVB ASI A Figure 6 Overview of the DA SDI C2 connector module Unused outputs should be terminated with 75 ohm DA SDI C2 does not have any GPI alarm outputs 4 1 Mounting the connector module The details of how the connector module is mounted is found in the user manual for the sub rack frame FR 2RU 10 2 This manual is also available from our web site http www network electronics com network electronics com 9 DA SDI NRC Rev 3 5 Module status The status of the module can be monitored in three ways 1 GYDA System Controller optional 2 GPI at the rear of the sub rack 3 LED s at the front of the sub rack Of these three the GPI and the LED s are mounted on the module itself whereas the GYDA System Controller is a separate module giving detailed inform
8. rm in equipment in Appendix A of General Rule of Environment Friendly Use Period of Electronic Information Products This is indicated by the product marking It is assumed that while the product is in normal use any batteries associated with real time clocks or battery backed RAM will be replaced at the regular intervals network electronics com 15 DA SDI NRC Rev 3 The EFUP relates only to the environmental impact of the product in normal use it does not imply that the product will continue to be supported for 50 years A 3 Recycling information Network Electronics provides assistance to customers and recyclers through our web site http www network electronics com Please contact Network Electronics Customer Support for assistance with recycling if this site does not show the information you require Where it is not possible to return the product to Network Electronics or its agents for recycling the following general information may be of assistance Before attempting disassembly ensure the product is completely disconnected from power and signal connections All major parts are marked or labelled to show their material content Depending on the date of manufacture this product may contain lead in solder Some circuit boards may contain battery backed memory devices network electronics com 16
9. ses in studio duplication and Broadcast applications SDI SDI2 SDI SDIS input SDH SDIS SDI6 SDI SDI8 Remote Control Figure 1 DA SDI NRC 270Mbps Serial Digital Distribution Amplifier network electronics com 4 DA SDI NRC 2 Specifications Electrical Input Data rate NRZ Data rate RZ Equalisation Impedance Return loss Signal level Connector Electrical Output Number of outputs Connector Impedance Return loss Jitter Peak to peak signal level Signal polarity Features Input equaliser Electrical Power Control Supported standards SMPTE AES Rev 3 1 to 540 Mbps 1 to 270 Mbps Automatic Cable equaliser can be bypassed to support bitrates down to 1Mbps 75 ohm gt 15dB 500kHz 270MHz nom 800mV approx 200mV min when equaliser switched to Bypass BNC 8 6 BNC 75 ohm gt 15dB 500kHz 270MHz max 0 2UI 0 8V 80mV 6 non inverting 2 inverting EQ bypass for low bit rates 5V DC 3W Max Control system for access to setup and module status with BITE Built In Test Equipment for use with GYDA Control System SMPTE 259M AES 3id with EQ switched off network electronics com 5 DA SDI NRC 3 Format configuration The DA SDI NRC can support a number of different formats The correct configuration can either be set with a DIP switch or with the GYDA Control System The layout of DA SDI NRC is shown in the
10. t Panel Status Monitoring cissscssnaceoxcegvodovans vos bouawesnadarvesaimequrans or rhenen enkelen 11 General environmental requirements for Network Electronics equipment 12 Certificate of CONO ursa rendeert haba ted EEVEE TEKS Sr EEVEE IRERE iee 13 PROCUCE Warranty oisi antses sive dasasoiwedn vas save sveuedannwdawadesessavescavadenavsewn erin cores ESE EEE KERER inae 14 Appendix A Materials declaration and recycling information enen 15 A 1 Materials declaration sneren er ete on abad eed aen tea 15 A 2 Environmentally friendly Use period ssscssnoreteerserssersersnssernermernsehaabanktnanwedtikdnensseereken de 15 AA R cycling INOPTMAL N eere eenen eenden 16 network electronics com 3 DA SDI NRC Rev 3 1 Product overview The Flashlink DA SDI NRC is a serial digital video distribution amplifier module providing high performance media distribution for various signal formats from 1Mbps up to 540Mbps The unit can be configured to do cable equalising of SMPTE 259M DVB ASI and other signal formats The input typically provides an automatic cable equaliser for up to 250 metres of cable Belden 8281A at 270Mbps with 8 outputs Special considerations has also been taken to enable all possible DVB ASI rates including empty transport streams with only K28 5 padding packets Outputs 1 6 are non inverting to support DVB ASI compatibility Outputs 7 and 8 are inverting The DA SDI NRC is designed for all distribution purpo