Home
M2M Pro 3 Family - Quick Reference Guide
Contents
1. If You would like to use the default configuration just push the 7 button please OPERATION STATUS LEDS LED Function Device state CED St Power on status fights when its started and boot is on the way SM HSxPA 2G 3G signal strength amp status blinks if connection is on the way lights if comm is okay red WiFi WiFi active status __blinks when WIF is under registration lights if the WIR operates and SSID available PACKAGE CONTENT M2M Pro 3 M2M Pro 3 CONCENTRATOR M2M Pro 3 I0 M2M Pro 3 WiFi MyGuard Hub router 1 2 3 comm antenna 12V power supply adapter Quick Guide Reference document Warranty Card In Case of MyGuard Hub security sensors remote controller power plug are also packed CERTIFICATIONS The device compliance with the CE certification directives with the following standards and partly accomplish to the further standards and rules RF Spectrum ETSI EN 301 511 V9 0 2 ETSI EN 301 908 1 v3 2 1 EMC ETSI EN 301 489 1 V1 4 ETSI EN 301 489 4 2000 08 ETSI EN 301 489 7 v1 3 1 ETSI EN 301 489 7 v1 3 1 ETSI EN 61000 1 2010 ETSI EN 61000 3 2 3 ETSI EN 61000 4 3 6 11 ETSI EN 61000 6 1 4 ETSI EN 55022 2006 A1 2007 ETSI EN 55024 2003 ETSI EN 50130 4 ETSI EN 300 328 ETSI EN 302 291 Mobile device compliance 3GPP TS 51 010 1 V4 3 0 ETSI EN 300 220 1 and FC part 15 247 amp 15 249 directives M2M technology ETSI TR 102 691 Smart Metering ETSI TR 50572 2011 ETSI TR 102 886 V1 1 1 Wireless
2. Ethernet RJ45 MBus Analog IO Digital IO PTSM Terminal Block for M2M Pro 3 IO Wireless connections 2G 3G ISM radio Zigbee WiFi Wireless M Bus Powerful WiFi router up to 254 connections and Zigbee gateway up to 230 connections ISM concentrator up to 254 connections Communication ways Ethernet Eth0 WIFI Onboard LAN Access Point Hotspot IEEE 802 11b g n PPPO 2G 3G Internet and WiFi Over Ethernet for ISP internet sharing Zigbee Network functionality Router Gateway APN ISP NetID TCP IP DHCP NAT Routing Port forwarding DynDNS FTP Client Server for camera or other external devices SNTP WPA WPA2 PSK Netbios SMPP SMS handle and monitoring VPN and Tunnelling Simple VPN PPTP Master Client IPSec L2TP client server Communication protocols TCP UDP transparent or filtered Modbus TCP master Modbus RTU RS485 or RS232 interface M BUS master Security Tools Firewall MAC filtering event logging log files operation logs service logs password protected admin login data encryption SSH AES External storage management amp sharing uSD memory card USB pendrive File Manager Format Mount Unmount Storage etc WiFi security functions WPA WPA2 PSK TKI AES MAC filtering MAC cloning disable WLAN radio Serial Connection RS232 and Industrial connection RS485 Wireless MBus support specialized serial port settings Short RF ISM and Zigbee settings USB Support for external storages
3. Hub home amp small business 3G router device amp WiFi AP HotSpot amp ZigBee connection for sensors meters The router amp concentrator builds up and sustain the communication bridge between the connected wireless devices Short RF ZigBee WiFi Wireless MBus as sensors meters and the remote center Almost any kind of the short range radio wireless devices can be connected to the router in the same time It collects the information from the managed devices identify them then forward to an M2M based central server through the secure mobile network 3G through an enclosed APN network The main goal of the router to connect the wired amp wireless devices on the network sentinel and assure the continuous network data traffic and unify the channels to integrate them into one info channel then forward the data towards the center The connected devices of the system makes a grid which could be utilized in many ways like sharing the internet receiving the information of sensors or measurement amp consumer data or it can be used for information exchange etc Through the collected and summarized information You ll able to offer real values like fresh information and value services for the home users the industrial partners or the customers of the service providers Through the IO extensions it can connect to the several input lines and interfaces like serial bus devices MBus analog amp digital input output lines The wireless radio
4. interface All M2M Pro3 members 10 100MBit auto negot half full duplex RJ45 connection 2G 3G ppp0 connection 2G module option Four band GSM GPRS module Cinterion TC63i with board 2 board connection operational modes 850 900 1800 1900 MHz GPRS Multislot Class 12 DL UL 86 kbps 2 75G module option Four band GSM GPRS EDGE module Cinterion MC75i with board 2 board connection operational modes 850 900 1800 1900 2100 MHz GPRS amp EDGE Multislot Class 12 DL UL 86 kbps GPRS 236 kbps EDGE g 3 5G module option Dual band GSM GPRS EDGE UMTS HSUPA HSDPA module Cinterion EHS 5 with board 2 board connection operational modes 850 1900 EHS5 US or 900 2100MHz EHS5 E GPRS amp EDGE Class 12 HSDPA HSUPA Class 6 8 DL up to 5 7 Mbps UL 7 2 Mbps or Five band HSDPA Cinterion PH8 module with board 2 board connection operational modes 850 900 1800 1900 2100MHz GPRS amp EDGE Class 12 HSDPA HSUPA Class 6 10 DL up to 5 7 Mbps UL 14 4 Mbps Short RF Short RF radio freq ISM signals ISM module option M2M Pro3 CONCENTRATOR MyGuard Hub Texas CC1101 module 433 868 MHz modular connection Zigbee PAN network Zigbee module option M2M Pro3 CONCENTRATOR MyGuard Hub Texas CC2531 module 2 4 GHz modular connection WiFi wlan connection WiFi module M2M Pro3 CONCENTRATOR MyGuard Hub Realtek RTL8188CUS module 2 4 GHz modular connection External antennas dedicat
5. pendrives disks etc Quick Reference Guide Real Time Clock RTC chip and coin cell battery for continuous time calendar functions receiving SNTP time and auto refresh Software fast and secure reliable customized special Linux distribution and software for industrial needs local web administration for configuration and check the operation status local web server and web UI settings parameters status options Operation Interface and Connection status logs backup amp restore config etc Intuitive web based wizard driven configuration local Ethernet remote by 2G 3G and Quick Setup all settings can be defined Remote control amp management Port settings Command Line Interface CLI Debug possibilities watchdog tcpdump monitoring M2M server connection central side data collection amp safe store evaluation visualization web interface event handling reports messaging alarm sending Signal transmission in case of input signal change transmits the alarm signals output line can be controlled by remotely Backup lithium accumulator against outages sabotage actions and Accu Recharge function Remote over the air software update function FOTA from M2M server Operation LEDs up to the HW versions 3 LEDs or 8 LEDs Integration of own developed softwares are also possible INTERFACE CONNECTORS Front side 1 12V power supply connector 2 Operation LEDs 3 Micro SD
6. remote metering ETSI EN 13757 2 2004 ETSI EN 13757 3 2004 ETSI EN 60870 5 101 ETSI EN 60870 5 102 ETSI EN 60870 5 103 ETSI EN 60870 5 104 ETSI EN 60870 5 1 M Bus ETSI EN1434 3 Wireless M Bus ETSI EN 13757 4 2005 IEEE Standard 802 15 4 Zigbee ETSI IEC 60870 61868 70 IEEE Standard 802 11b g i n WiFi ETSI EN 302 544 IEEE Standard 802 3 Ethernet ISO IEC 8802 3 ISM Standard RF 868MHz ETSI 302 208 1 ETSI 302 208 2 2G 3G network standards GPRS GSM network IP IEC 62056 62 6 61 EDGE ETSI EN 301 489 50 V1 2 1 ETSI EN 301 908 8 9 UMTS ETSI ETSI EN 301 123 ETS 300 905 ETSI TR 123 909 HSDPA TS 125 317 TS 125 308 HSUPA TS 125 101 LTE TS 136 141 TCP IP communication IEC 62056 53 ETSI EN 302 665 V1 1 1 TCP UDP server comm TS 102 483 V7 1 0 Security compliance ETSI EN 50131 ETSI EN 50164 ETSI EN 62305 4 ETSI EN 50130 Alarm signal transmitting device compliance ETSI EN 50136 1 1 2 3 4 5 2006 Signaling and remote monitoring solutions compliance ETSI EN 50134 Intrusion and defensive systems compliance ETSI EN 50131 1 Alarming system compliance ETSI EN 50131 5 3 2005 A1 2008 Alarming system environmental conditions ETSI EN 50130 5 Alarming system and intrusion amp prevention systems part 3 Control and display EN 50131 3 2009 Alarming system and intrusion amp prevention systems part 7 Application regulations CLC TS 50131 7 2010 Central monitoring amp surveillance signal receiver systems ETSI EN 501
7. 38 1 2 3 Alarming system and intrusion amp prevention systems power supply ETSI EN 50131 6 2008 Emergency call systems ETSI EN 50133 1 2 3 5 7 Alarm systems passive infrared sensors ETSI EN 50131 2 2 Alam systems combined IR and microwave sensors ETSI EN 50131 2 4 Digital Video Broadcasting DVB ETSI ES 202 218 Video streaming ETSI EN 50132 5 2001 Video surveillance ETSI EN 50131 1 2006 A1 2010 ETSI EN 50132 1 2010 Safety amp Health ETSI EN 60950 1 2006 A1 2010 ETSI EN 50371 2002 Environmetal Testing IEC 60068 not be disposed of in the household waste but sent for recycling Please take it to a collection point designated by your local authorities once it has reached the end of its life some will accept Fe This product assigned with CE symbol according to the European regulations This symbol on the product or packaging means that according to local laws and regulations this product should be DEd products for free By recycling the product and its packaging in this manner you help to conserve the environment and protect human health it
8. M2M Pro 3 Family M2M Pro3 Family members as M2M Pro3 M2M Pro3 CONCENTRATOR M2M Pro3 WiFi M2M Pro3 10 MyGuard Hub These members are 3G WiFi router Zigbee ISM gateway and Wireless MBus data concentrator devices with wired amp wireless connection capabilities The universal device works as and industrial computer with several multifunctional network services and supports a long list of wireless communication standards and installed applications Application modes Can be used for private Security tasks amp Safeguarding as an advanced alarm center Surveillance center for Home and Office Video surveillance and ATM supervision Home Automation and Intelligent Home tasks Industrial applications data collection connecting devices Monitoring Base station amp server monitoring cash registers Smart Metering and AMI tasks Telemetry eHealth Home amp Office Internet sharing ISP 3G Alternative DSL ISP backup and advanced router functions The device has a common hardware platform which has four different hardware contexts as diverse modular constructions M2M Pro3 industrial 3G router device with Ethernet USB interface M2M Pro3 CONCENTRATOR industrial 2G 3G router amp data concentrator with wireless MBus capabilities and Ethernet USB interface M2M Pro3 IO industrial 2G router device with M Bus capabilities wired RS232 RS485 Modbus and analog digital IO interface M2M Pro3 WiFi MyGuard
9. ase with aluminum holder The circuit can be fixed with four screws to a fixation point the sealable cover can be fixed with four screws CE certification and compatible international standards and needs IMPORTANT INFORMATION for M2M Pro 3 IO only not available for MyGuard Hub for M2M Pro 3 CONCENTRATOR only for MyGuard Hub only INSTALLATION STEPS Step1 Switch off the electric connection if it was already connected then insert an activated SIM card into the SIM bay 4 socket the cutted side of the SIM card must be inside and the chip side of the SIM card looks to the M2M Pro3 s PCB circuit Push to fit the card Step2 Mount the SMA antenna connectors 9 regarding the antenna type titles on the device Step3 Connect the 12 VDC Power supply adapter wire into the the Power supply connector 1 of the device Step4 Connect the Ethernet UTP cable to the connector 8 of the M2M Pro3 and the next side of the cable to Your computer Then You can access the web administration interface for configuring the router regarding the User Manual from a web browser at the http 192 168 127 1 8080 address user admin password password Step5 If You use the Pro3 IO version and You d like to use the wired connections You have to connect them 10 11 12 13 14 with the current wires and the outer device Step6 If You d like to use memory card to the 3 or a USB pendrive at 5 connect them
10. connections and wireless internet connection standards makes it able to connect industrial PLCs analyzators measurement devices cameras sensors PCs servers network components automates etc The built in WiFi Hotspot and Access Point gives the possibility to share the mobile internet and ISP s internet line access for Your surround All redirected data and managed devices can be seen as evaluated data on the central server side or can be accessed by the web or a phone It s possible to monitor the input lines device health and their events amp current status signal changes There You will be able to measure track and control Your elements and able to receive alarms measured values status life signals of all connected grid components The design of the router makes it possible to use it under continuous operation which guarantees high availability HA and reliability It has remote management access function and which increases the efficiency of the present system with continous accessibility It was developed for industrial conditions robust design and cover which fits to the thermal conditions and can be used with high quality and reliable cellular modules like a 2G 2 75G GPRS or EDGE capable or a 3 5G HSxPA modem The configuration is possible on the local webadmin interface or at the website The operation LED signals of the router are easy to understand COMMUNICATION PROPERTIES Wired Ethernet eth0 connection g Ethernet
11. ed antenna mounts for wireless standards 2G 3G antenna Frequency range 850 960MHz 1710 1880 2100 MHz Antenna interface 50 Ohm 2 2 dB or more gained Connector mount SMA ISM Zigbee antenna Frequency range 850 960MHz 1710 1880 2100 2400 MHz Antenna interface 50 Ohm 2 2 dB gained Connector mount SMA WiFi antenna Frequency range 850 960MHz 1710 1880 2400 MHz Antenna interface 50 Ohm 3 dB or more gained Connector mount SMA MAIN FEATURES Built in Powerful ATMEL ARM926 based Embedded MPU processor 400 MHz frequency 400 MIPS 32 bits ARM9 architecture Wide range of memory fields 8Mbyte data flash 64 MByte NAND flash 128 MByte DDR2 RAM external microSD card and USB stick pendrive option for storage of operation system and programms configuration logs etc High availability realiability high accuracy and stability online operation g Fail safe operation backup amp recovery options default amp zero config integrity check Network connection auto check rebuild amp auto repair in case of 2G 3G network hangups and outages in case of WiFi detection of comm outages and auto recovery and AP auto channel selection Specialized 3G WiFi router WiFi Access Point Hotspot Zigbee ISM gateway and Wireless MBus meter concentrator Forwards data of the connected devices and life signals to the remote center transparental or filtered communication Wired interfaces 2xUSB 1xminiUSB 1xRS232 1xRS485
12. memory slot 4 Push push insert SIM card bay 5 2x USB v2 0 connector Hi Speed 480 Mbps 6 mini USB device connector Hi Speed 7 Reset config button 8 Ethernet port 10 100 MBit Auto NDX RJ45 Bottom side 9 SMA antenna connectors 2G 3G WiFi Zigbee ISM up to the HW version 10 Serial port RS232 fast full duplexity PTSM Terminal Block 11 Industrial port RS485 full dupl PTSM 12 Modbus connector PTSM Terminal Bl 13 Digital input output lines PTSM T B 14 Analog input output lines PTSM T B Temperature limits Operational between 40 C and 70 C Storage temperature between 40 C and 80 C at 0 95 non a condensing humidity Notes that water icing dewing not allowed take care when temperature decreasing GUARD POWER CURRENT ENVIRONMENTAL PROTECTION Power supply 12 VDC 1 2 3A through 230V 12V power supply adapter Digital input line high level 2V low level 1V Digital output 0 3A 125VAC 1A 30 VDC Analog input output line OV 10V 12bit Current in active operation OMA 24mA 12bit Rated current stand by current 385mA 12V average current 640mA 940mA 12V maximum current 1300mA 12V IP31 immunity protection TECHNICAL CONSTRUCTION AND DESIGN Dimensions WxLxH 215x138x50mm 90x80x31mm 104x104x31mm up to HW version PCB only 90 x 77 x 22mm The PCB circuit can be enclosed into an aluminum plastic c
Download Pdf Manuals
Related Search
Related Contents
報告書(本文) Colle de poisson sta bilisée MODE D`EMPLOI DU KIT «DÉFI POUR LE TERRE» 橡 無題 8校_AV-LS500V取扱説明書 B-MANU200988 壁掛形非常業務兼用放送設備 Copyright © All rights reserved.
Failed to retrieve file