Contents

1. 0 or 1 0 add 1 delete wireless 7 No setting ENT YY Zone numbe Includes 00 15 sensors On Off of door amp window state 9 9 X ENT X O or 1 0 closed 1 open 0 check If upload arm amp disarm to 5 5 X ENT X 0 or 1 0 Not upload 1 Upload 0 Unnecessary Management to know center 8 0 ENT XXXX nE User Code 8 X X X X 4 digit user code No code ENT Note Press ESC to exit from the programming state after finishing programming How to change programming password Users must know and operate In order to keep program password safe and to be easily remembered users can change it via below setting SET 999999 ENT Six Digital New Programming Passwords ENT Six Digital New Programming Passwords ENT Notes 1 Press SET then programming light on After finishing setup programming light off 2 The sound Di Di from the alarm host indicates successful operation Di Di indicates failed operation How to operate the Alarm Host Necessary for users to know and operate To record a voice message greeting Slide the switch on the left side of the alarm host to the RECORD ON press and hold the Microphone P button speak close into the rear side speaker of host and then release the microphone A when finish with voice message greeting Voice message greeting can be anywhere between 0 9
2. is setting Armed home please take notes that Arm Home is only effective for sensors in Perimeter Zone door sensor curtain PIR sensor and sensors in Emergency Zone Like Gas sensor Smoke sensor Glass sensor Emergency button it is not effective all sensors in Motion zone Like wide angle PIR Please replace the batteries after one year usage and when you feel shorter control distance How to program A Add 1 Start to program Please refer to Table 2 2 Wireless configuration 70 ENT 00 ENT At this time Learn light keep on Press any key on remote controller twice successively if you hear Di form the alarm host and see the Learn light flashes five times and off it indicates successfully added B Delete 3 Start to program Please refer to Table 2 4 Wireless configuration 71 ENT 00 ENT if you hear Di Di form the alarm host and see the Learn light flashes two times and off it indicates successfully cancelled Notes 1 You can only add 1 remote controller each time totally 10 available to be added 2 All the remote controllers are cancelled after your cancelling operation You have to do the adding operation if you need one or more Wireless Door Sensor Features Generally set as Perimeter zone if any door or window is opened it will transmit the alarm signals to the alarm host Specifications Operating power 23A 12V alkaline battery oj Emitting distan
3. of door and window When the smart zone is ON the arm operation is normal if all the doors or windows are closed But if any door or window is open the host will sounds Di Di Di and at the same time the status light flashes frequently Note 1 This function is available only with wireless intelligent door sensor programmed 2 If arm by phone call the operation is same as original 3 If arm by remote controller or wireless keypad it will arm successfully after two succsessive arm operation Wireless Ding Dong doorbell the alarm host will sounds Ding Dong three times after each press of the doorbell button Note This is an optional function To have this function need to add and program a wireless doorbell button 5 Cautions Alarm processing mode immediately after the system alarms it starts to dial in sequence from the st group number to the 5h group number skip empty numbers automatically It dials circularly for three times the answered number and the numbers succussfully reveived SMS will not dial repeatedly Exit delay alert the alarm host sounds Di every 1 second door window is closed within preset exit delay time Alarm delay alert the alarm host sounds Di every 1 second within preset alarm delay time Alarm priority 1 If the alarm host s own telephone line is accupied when it is alarming it will cut it and make it unoccupied at the same time dial out to report alarm event 2 T
4. running out batteries to ensure the normal operation of them You d better keep the power of the alarm host and all wireless accessories off while a long time vacancy of the system
5. 0 C Humidity lt 80 Product dimension 150x107x26 mm 2 Zone types and definitions Zone types Perimeter zone Motion zone Emergency zone Definitions Perimeter zone Detecting the space like doors windows etc generally use wireless door magnet sensors and wireless curtain PIR sensors Motion zone Detecting the space like living room aisles and bedrooms etc generally use wireless wide angle PIR sensors Emergency zone Detecting the space like Emergency area such as emergency distress medical rescue gas leakage and fire alarm etc this zone keep 24 hour monitoring status automatically Generally use panic button wireless gas sensors and wireless smoke sensors 3 Modes of arming Away Arm mode Once any detectors in perimeter zones or motion zones get triggered the host will alarm immediately and meantime dial automatically Home Arm mode Once any detectors in perimeter zones get triggered the host will alarm immediately and meantime dial automatically It will not alarm after any detectors in the motion zone are triggered 4 How to operate the alarm host Preparation 1 Insert SIM card properly 2 Fix the antenna 3 Connect the telephone cable connect the telephone cable of telecommunication to Tel in port on the alarm host thenuse the telephone cable attached in the package to connect Tel out port and telephone set 4 Connect power connect the power adapt
6. At this time Learn light keep on Notes XX indicates group number of defense zone including 11 15 Press the Learning Emitting Switch twice successively to trigger PIR sensor if you hear Di form the alarm host and see the Learn light flashes five times and off it indicates successfully added B Cancel 1 Start to program Please refer to Table 2 2 Wireless configuration 71 ENT XX ENT if you hear Di Di form the alarm host and see the Learn light flashes two times and off it indicates successfully cancelled Notes 1 You can only add 1 wireless PIR sensor each time Each group is available to add 4 wireless PIR sensors 2 When exceeds 4 the latter added wireless PIR sensors will cover the former added one 3 All the wireless PIR sensors in this group are cancelled after your cancelling operation for one group You have to do the adding operation if you need one or more Wired Siren omitted Symptoms of Faults Possible Cause Solution The alarm host can t fully record Repeatedly receiving the alarm telephone Can t receive alarm sms or can t receive sms reply after made arm or disarm operation by sms Did not keep pressing the record button all the time while recording Fail to operate according to the operation instruction of the telephone alarm 1 SIM card is not insert properly 2 GSM signal is not good enough Keep pressing the
7. User s manual for GSM Touch Screen Wireless Alarm System Thank you for purchasing and using GSM LED wireless alarm system This is a Hi tech household security product It will make your life safer and colorful Please read the below information carefully before using for a proper usage A Product components This product is composed of alarm host basic accessories and optional accessories Alarm Host Basic Accessories Wireless Optional Accessories Wireless digital sensor wireless motion sensor GSM LED Alarm remote wireless door sensor wireless wireless gas alarm smoke alarm wireless Host wide angle PIR sensor wired siren indoor and outdoor siren doorbell button wireless LED keypad wireless LCD keypad OY OO Pe Ot Ne 14 15 A LED displays Date GSM 2 4 Band Net trasmission phone audible alarming and SMS alarming 15 wireless zones Each zone supports up to 4 sensors Supports 8 more wired zones Optional Can preset up to 6 phone numbers and dial in sequence Intelligent logic analysis technology corresponding zone number can be ideitified from LED indicators Arm Disarm the system by 5 ways SMS Main Host Keypad Wireless Keypad Keychain Remotes or even remotely by phones Available in AC DC with Low voltage Indicators Learning sensors to alarm host very easy operation Non volatile chip information stored automatically when off power Check door window status automatically This i
8. ce 2100m in open area ol Service life lt 1 year Alarm Distance lt 4cm Installation and Usage Fix the part of magnet onto the door frame in a position of 1 6m o above the ground to prevent any children from bumping onto it Fix the part of emitting onto the door frame make sure to keep the part of magnet and part of emitting in parallel the space between the two parts shall be less than 10mm Upon the working light flashes frequently in blue please replace the batteries How to add and delete door sensors A Add 1 Start to program Please refer to Table 2 2 Wireless configuration 70 ENT XX ENT At this time Learn light keep on Notes XX indicates group number of defense zone including 01 06 Trigger the door sensor twice successively if you hear Di form the alarm host and see the Learn light flashes five times and off it indicates successfully added B Delete 1 Start to program Please refer to Table 2 2 Wireless configuration 71 ENT XX ENT if you hear Di Di form the alarm host and see the Learn light flashes two times and off it indicates successfully cancelled Notes 1 You can only add 1 wireless door sensor each time Each group is available to add 4 wireless door sensors 2 When exceeds 4 the latter added wireless door sensors will cover the former added one 3 All the wireless door sensor in this group are cancelled after your cancelling op
9. er SMS reporting Mobile will get SMS like System Alarming XX YYYY XX means zone number YYYY means the detailed sensor Armremotely by phone 30 seconds after successfully dial the telephone number of host enter the password of host after the beep enter 1 after beep the host will automatically hang up after beep to successfully complete the operation Notes You can set Armed Away remotely by phone but keep notes that you can t set Armed Home by this way Disarm remotely by phone 30 seconds after successfully dial the telephone number of host enter the password of host after the beep enter 0 after beep the host will automatically hang up after beep to successfully complete the operation lt Armby SMS You can edit SMS XXXXXXBF to host panel the host panel would arm automatically when getting this SMS and also will message back to mobile Arm successfully Notes Arm by SMS is only for Armed away Disarmby SMS You can edit SMS XXXXXXCEF to host panel the host panel would disarm automatically when getting this SMS and also will message back to mobile Disarm successfully How to use the extended functions Separate arm and disarm of 8 wired zones When the host is armed press 1 8 number key can arm disarm the cooresponding zone Status light of the cooresponding zone on indicates armed off indicates disarmed Monitor open and closed states
10. eration for one group You have to do the adding operation if you need one or more Wireless Wide Angle PIR Sensor Features Mainly monitor and control indoor stereoscopic space generally set in Motion Zone When human body enters into the Low detecting area the sensor will transmit Ty ight the alarm signals to the alarm host Specifications Operating power 9V alkaline battery Emitting distance 2150m in open area Service life lt 1 years Detecting distance 110 10x10m O Emitting button TET Power Right ON Switch Left OFF Installation and Usage Fix the bracket on suitable wall surface or in wall corner at a distance of 2 2 4m above the ground Open the sensor shell to connect the batteries well and adjust jumper line short circuit 5S The sensor will detect once every 5 seconds short circuit SMIN The sensor will detect once every 5 minutes suggestion short circuit 5S for testing and 5MIN for normal use Fix the sensor onto the bracket Adjust the sensor to a proper angle and then slide the power switch on the side to ON and it will enter into the normal working state after 30 seconds Upon the working light flashes frequently in blue please replace the batteries How to add and delete door sensors A Add 1 Start to program Please refer to Table 2 2 Wireless configuration 70 ENT XX ENT
11. he alarm host s Ding Dong sound will switch to alarm sound and dial to report if it receives alarms signal when sounds Ding Dong Lower voltage alert Low Power light on the host will be on when power gets very low Wireless zones Zone Number Sensor Type Zone Type Applicable Sensor Name Remark 00 Wireless remote amp Wireless Keypad Wireless Smoke Alarm 01 05 Emergency zone r Supports upto E Wireless Gas Alarm amp Panic button etc 4 wireless EES 2 Sensors Wireless Door Window Sensor amp 06 10 Perimeter zone sensors for Wireless Curtain PIR etc each zone f Wireless Wide Angle PIR Motion Sensor 11 15 Motion zone etc Note Default set before shipment Wireless Wireless Wireless door Wireless wide angle Wireless gas Wireless sensor remote sensor PIR sensor sensor smoke sensor Zone Number 00 06 11 02 03 B Understanding of Basic Accessories Wireless Wireless Remote Away EN Features e ray p To control the alarm host to arm and disarm Disarm With the emergency key for urgent help P Home Specifications Operating power 27A 12V alkaline battery Emitting distance 2100m in open area Service life lt 1 year Installation and Usage For users to take along Generally press the Away key to arm before leaving home and press the Disarm key to disarm Home
12. or to DC port of the alarm host first then plug it to the AC socket 5 Turn on the backup battery 6 Check and see if GSM signal is good enough s Signal is not normal or SIM card not Type GSM Signal OK inserted properly 2 Band 900 1800 MHZ Signal indicator keeps flash about l a Signal indicator keeps on every 2 seconds 4 Band 850 900 1800 900 MHZ Signal indicator keeps flash about Signal indicator keeps flash about every 3 seconds every 1 seconds How to program Notes classification To be Cod r Default Setting Operation Instruction For users programmed e Setting Start to aye SET XXXXXX ENT XXXXXX 6 digit program password 888888 program X Group number of telephone numbers includes1 6 Necessary to 0 X ENT Tel 1 for C ID protocol know Input phone 0 number ENT 2 for XSJ protocol No number numbers n Y ENT 3 6 for personal 12 digits at most Y 0 or 1 0 phone alarm 1 SMS alarm X O or 1 0 O second 1 15 May know Exit delay 1 1 X ENT 0 seconds X O or 1 0 0 second 1 15 Entry delay 2 2 X ENT 0 seconds Emergency 3 3 X ENT X 0 or 1 O silent 1 audiable 1 alarm sound Perimeter zone motion 4 4 X ENT X O or 1 0 silent 1 audiable 1 zon alarm sound Program i 7 X ENT Y Y X
13. record button all the time while recording Follow the below instructions after answering the alarm phone calls and hearing the recorded message See Point 6 of How to operate the Alarm Host 1 Insert SIM card properly 2 Adjust alarm host s installation position till the signal status shows OK The host does not alarm after the detector is triggered in arm state 1 Caused by the functions of arm mode Armed Away and Armed Home 2 Have already setup time for Entry Delay or Exit Delay 1 Armed Away mode alarm goes off when any sensor is triggered 2 Armed Home mode alarm goes off when any sensor in Perimeter zone is triggered and it won t alarm when any sensor in Motion zone is triggered 3 Program to adjust the time for Entry Delay or Exit Delay The PIR sensor doesn t work 1 Not properly connected to the power 2 Port of the detector is in the power down mode 1 Open the sensor shells to install the batteries well and slide the power switch to On 2 5S detect once every 5 seconds SMIN detect once every 5 minutes The detecting distance of PIR sensor gets shorter The ambient temperature in the detecting area is too high When the ambient temperature in the detecting area exceeds the human body temperature the detecting distance will get shorter it s normal The host does not alarm after Failed
14. s when the system is disarmed only if a door is opened it will sound fast bi bi bi Support wireless ding dong doorbell function Optional Support CID uploading to CMS Center monitoring Station can user our GSM CID connector to have this function Disconnection alarm auto priority to occupy the telephone and monitoring function to hear what is happening Built in Li lon backup battery it will alert when low power or without external power supply Store up to 100 alarm records and 100 arm disarm records Understanding of the Alarm Host GSM Antenna li Arm Away hs GSM ALARM SYSTEM _ Arm Home 2 E i E a Status Indicator g E d Le m Signal Indicator 7 a 0J sr we wilt a 4 Low Power Indicator Oa Fe Ee 4 ons Emergency Back Space Number Confirm 4 Record Play Esc Disarm Program Power SIM Card SIM MIC BackUp Record Exit Button Card Seat Battery ON OFF ON OFF 1 Specifications Working power AC 100 230V DC 12V 1A Static current lt 50mA when not charging Alarm current lt 500mA Built in Li lon backup battery 3 7V 800mAH rechargeable Standby around 24 hours Full charging time 12 hours 2 Band GSM GSM900 1800Mhz 4 Band is optional 850 900 1800 1900Mhz GSM transmit power 2W Receiving and emitting frequency 433MHz Working condition Temperature 10 C 5
15. seconds long To Playback the recorded voice message greeting Slide the switch on the left side of the alarm host to DC ON press and hold the playback button to playback the recorded voice message greeting Arm BY wireless remote press the corresponding arm button and the host will beep once to successfully complete the operation By Host panel Keypad press A W to choose armed away or armed home Disarm By wireless remote press the corresponding disarm button and the host will beep twice to successfully complete the operation By Host panel Keypad ESC master code ENT the host will beep twice to successfully complete the operation Emergency By wireless remote Press Emergency key and the host will alarm immediately By host panel Keypad press and the host will alarm immediately Telephone alarm After receiving the call you will hear the recorded voice message immediately it can be played for 30 seconds repeatedly then follow the below instruction 1 Input 8 to enter into the listening status for 20 seconds automatically you can hear the alarming event sounds from phone Each extra press of 8 can prolong 20 second listening in Input to play the recorded voice message for one time automatically 3 Input the host will end the call and stop dialing any auto dialer Directly hang off the telephone the host will end the call and automatically dial the next auto dial
16. to follow the operation Follow the operation instruction of How to the new added wireless instruction of Adding and deleting program to activate the new wireless sensor detector is triggered sensors to add the new wireless sensor The PIR sensor flashes Batteries are running out Replace with new batteries of the same frequently in blue specification The door sensor s indicator Batteries are running out Replace with new batteries of the same flashes frequently specification The distance of the remote Batteries are running out Replace with new batteries of the same controller gets shorter specification This alarm is the hi tech product with the outstanding design and sophisticated technique and shall be used carefully To make the alarm to operate for a long term stably and to prolong the service life it is recommended that Try to put the alarm host in the dry and well ventilated places Do not put the host and any wireless detectors in too cold too hot or dusty places to prevent it from curtailing the service lives of electric parts and preventing the plastic shell from distorting and accelerating to age Do not put the host and any wireless detectors in low and too exposed places to prevent the children from touching them or the thieves from finding them Regular testing is necessary for finding and resolving problems in time Regularly check the batteries in all wireless sensors and replace the