Home

installation guide

image

Contents

1. Total horizontal length Count the vertical lengths Flue pipe length H Total 17 lt lt 2m 2m Am lm 4m lm 6m lm lm lm faber 12 Table Find the correct vertical and horizontal lengths in the table In case of an x or if the values are outside the table the combination is not permitted The value found indicates the width of the restrictor to be placed 0 means no restrictor should be placed Generally a 30mm restrictor is pre installed Verticaal 18 lt lt 0 N O vu A WW N e Hm N m O 30 40 40 45 50 60 65 70 70 70 75 80 O X X N 40 40 45 50 60 65 70 70 70 Horizontaal 30 30 30 40 45 50 60 65 70 O O X X X o ONU x EG x MEA u es oe lt i MM o X gt gt X X X faber 13 Technical data RE masa Reference gas Input Nett Efficiency class NOx class inlet pressure Gas rate at 159C and 1013 mbar Gas rate at 159C and 1013 mbar Burner pressure at full mark Injector main burner Reduced input restraint Pilot assembly Code Diameter inlet outlet Gas control valve Gas connection Electrical connection Batteries receiver Batteries sender 19 lt lt kW mbar l h gr h mbar mm mm mm 1 C31 C11 C31 C11 C31 G20 G30 G31 12 2 2 4 20 1278 11 2x 2 5mm 2 1 SIT 160 Nr 51 200 130 GV60 3 8 220 4x AA 1 5V 11 2 4 30 339 950 24 2x 1 3mm 1 1 SIT160 Nr 30 200
2. 130 GV60 3 8 220 4x AA 1 5 9 11 2 4 37 432 910 29 6 2x 1 3mm 11 SIT 160 Nr 30 200 130 GV60 3 8 220 4x AA 1 5V faber 14 Dimentions of the appliance left hand side 173 399 uitw 500 max 20 lt lt lt faber DD 15 Dimensions of the appliance left hand side with decoration plate 964 420 ultw 4 9 max 21 lt lt faber 16 Dimentions of the appliance right hand side GLI OOS faber 22 lt lt lt DO 17 Dimensions of the appliance right hand side with decoration plate D 200 173 420 ultw 4 9 max _ 23 lt faber 18 Dimentions ventilatie grills 24 lt lt SA TIC Add X IILI JL X Lt DI C ILT TE AE FE CE TOU X Y MT ILC W _ IIT faber 19 Dimention service Hatch 250 faber 25 lt lt 26 lt lt faber faber www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501
3. e Construct the false chimney breast against the build in frame see fig 1 1 B Keep a minimum margin of 3 mm between chimney breast and the appliance in connection with the expansion of the appliance e depth of the recess has no influence on the removal of the glass 4 9 Frameless with optional decorative sheet e Construct the false chimney breast around against the build in frame see fig 1 1 B apart from the lower half Keep a minimum margin of 3 mm between chimney breast and the appliance in connection with the expansion of the hearth e The height of the lower half should correspond with the height of the groove see fig 1 5 e Place the decorative sheet on top the build in frame 5 removing the glass 5 1 removing the glass in front e Remove the cover strips A on the side see fig 2 1 e Remove cover strip B on the bottom see fig 2 2 e Place the suction discs onto the glass e Remove the sealing cord from the groove see fig 2 3 e Slide the glass to the side and upwards so that the bottom edge is released from the groove Now gradually move the glass outwards and downwards see fig 2 4 5 2 removing the glass on the side It is not necessary to take out the glass on the side for placing the artificial logs or for maintenance purposes 11 lt lt faber e Remove the front glass first e Place the suction discs onto the glass e Remove the sealing cord from the groove e Slide the glass upwards
4. applied The false chimney breast and its construction may not rest on the appliance 3 3 Requirements flue system and outlets You should always make use of the materials prescribed by Faber International Ltd Only by using these materials can Faber International Ltd guarantee a proper functioning The outside of the concentric flue material can reach a temperature of Approx 150 C Make sure of proper isulation and protection in case of transit through combustible wall or ceiling constructions And observe sufficient distance Make sure that the concentric flue materials are bracketed every 2 metres when they have an extended length so that the weight of the flue material is not resting on the appliance itself You may never start with a cut down concentric pipe directly on to the appliance 8 lt lt faber 3 4 terminals The flue outlet can end on an external wall or a roof Check whether the outlet desired by you complies with local requirements concerning good function and ventilation systems For a proper functioning the terminal should be at least 0 5 m away from e Corners of the building e Roof overhangs and balconies e Eaves with the exception of the roof ridge 4 Preparation and Installation instructions 4 1 Gas connection The gas connection must comply with locally valid standards We advise Pipe work from the meter to the appliance must be of adequate size with near the appliance a gas isolater tap that sh
5. check the flame picture into the appliance 6 2 Pebbles e Remove the burner plates F see fig 3 2 e Place the pebbles over the burner and the bottom Spread the pebbles evenly to a 12 faber double layer The surface of the pebbles may be very slightly higher than the burner tube see fig 3 3 e Place the glass and check the flame picture into the appliance 7 Checking the installation 7 1 Checking the ignition of the pilot burner main burner Start the pilot and main burner according to the instructions in the user s manual e Check whether the pilot light is properly positioned above the main burner and is not covered by chips an imitation log or pebbles e Check the ignition of the main burner at full mark or low mark the ignition should take place quickly and easily 7 2 Checking for gas leakage Check all connections and joins for possible gas leaks by means of a gas leak detector or spray 7 3 Checking the burner pressure and the pre pressure Check whether the burner pressure and the inlet pressure measured agree with the data indicated on the registration plate Measuring the inlet pressure e Turn off the gas control tap e Open the pressure gauge nipple B see figure 1 7 a few turns and connect a pressure gauge hose to the gas control valve e Carry out this measurement when the appliance is on at full gas mark and when it is on the pilot light e the inlet pressure is too high you are not pe
6. now so that the bottom edge is released from the groove Now gradually move the bottom edge of the glass forwards slantwise and lower the glass into the opening between the build in frame and the appliance see fig and 2 5 2 6 and 2 7 e Now gradually move the top edge of the glass forwards and upwards out of the appliance see fig 2 8 To replace the glass repeat the process in reverse order Remove all Fingerprints from the glass these will be burned into it once the hearth is used 6 Plaatsen van het decoratiemateriaal It is not allowed to add different or more materials to the combustion chamber Always keep the pilot burner free from decorative material Do not toss all the decorative material onto the burner all at once asthe very fine dust may block the holes in the burner 6 1 Imitation logs e Spread the vermiculate preferably by hand over the tube burners in the burner slot The surface of the pebbles may be very slightly elevated from the burner plate but it should be level throughout the entire length e Place the imitation logs according to instructions see fig 3 1 or the instruction card e It is optional whether you apply chips to the combustion chamber or not Prevent chips from covering the burner this has a negative effect on the fire image e Start the pilot en main burner according to the instructions in the user s manual Assess whether the flame distribution is correct e Place the glass and
7. shortly after a renovation The first time the appliance is switched on Let the fire run on maximum setting for several hours so that the lacquer coating will have an opportunity to set and possible vapours released can be safely removed by ventilation We advise you to be outside the room as much as possible during this process Please note that 1 all transport packaging should be removed 2 children or pets should not be present in the room 7 lt lt faber 3 Installation requirements 3 1 Thefire The appliance must be built into an existing or a newly to be constructed false chimney breast In appliances with flexible gas pipes the gas control valve is mounted to the right side of the fire for safe transport Unscrew it and mount it at a distance of max 30 cm behind the access door The receiver which has been attached in a transport holder see fig 1 6 A to the side of control valve bracket can now be slid onto the top of the control valve bracket The transport holder can be removed now 3 2 False Chimney breast The false chimney breast must be constructed of an non combustible material Always ventilate the space above the appliance by means of the grills or a comparable alternative with a minimum air supply of 200 cm For the finish use special stucco min 100 C resistant or glass fibre wallpaper to prevent discoloration or cracks etc Recommended drying time for plaster is a minimum of 24 hours per mm of coat
8. 6260 6tLOTOOt cD Duet XL Installation guide faber a 1 lt lt lt faber 2 lt lt lt faber 3 lt lt lt faber 4 lt lt lt faber Table of contents L RUO CUON uuu OO o o Pr 7 2 Sein TUON 7 3 Installation requirements eem emen nns 8 3 1 PP o o UE O EET 8 3 2 False Chimney breast Hee rr 8 3 3 Requirements flue system and OUtletS nnn 8 3 4 l I ee uuu ii 9 4 Preparation and Installation INStrUCtIONS rr nn 9 4 1 nn UE O 9 4 2 ES NIE COMME On 9 4 3 Preparation of the appliance nnne 9 4 4 Plast Ene pi u orco REIR FEPUR YET UNDC EIC ETER HORE dao 10 4 5 Mounting the smoke emission outlet 5 10 4 6 Building a false chimney breast mnn 10 4 7 False CIM Oy Drea x uuu mayi aa DE E 11 4 8 Frameless without optional decorative sheet 11 4 9 Frameless with optional decorative sheet 11 gt ERE OASE uuu 11 5 1 removing the glass in front mmm 11 9 2 removing the glass on the 51 nnn 11 6 Plaatsen van het decoratiemateriaal nn 12 6 1 lil Oh 12 6 2 PEDDIE 12 f Checking the installation scans e eo
9. O Eein 13 7 1 Checking the ignition of the pilot burner main 13 1 2 Checking for gas 13 7 3 Checking the burner pressure and the pre pressure 13 7 4 Checking the flame picture r rr Hmmm 14 8 Instructing the Client hee een 14 9 Annual maintenance nena nnn 15 9 1 Service and cleaning 15 9 2 suba ee an i a ar 15 9 3 Elle eno RE E 15 10 Conversion to a different type of gas e g propane 15 11 Calcul dE IUS rea 16 5 lt faber 12 13 14 15 16 17 18 19 Points of particular interest rr rr Hee nnns 16 Sample computationsS eme ens 17 Td a ee E 18 TECH I hi u E E rari Deere 19 Dimentions of the appliance left hand side 20 Dimensions of the appliance left hand side with decoration plate 21 Dimentions of the appliance right hand SIGE ne 22 Dimensions of the appliance right hand side with decoration plate 23 Dimentions ventilatie 15 mme 24 uu y bee REOR ob 25 6 lt lt faber 1 Introduction The applia
10. counts as 1 metre To define the horizontal length all lengths of flue pipes in a horizontal direction should be added up every 90 bend in the horizontal part counts as 2 metres every 45 bend in the horizontal part counts as 1 metre Turns from vertical to horizontal or vice versa are not reckoned in the calculation The wall terminal always counts as 1 metre If there is transit under 45 then the real vertical and horizontal lengths should be calculated 11 1 Points of particular interest In case of a wall terminal the entire flue system including the wall terminal should be constructed of 200 130 flue pipes In case of a roof terminal the entire flue system should be constructed of 200 130 flue pipes apart from the roof terminal which should be constructed of 150 100 and should be connected by means of a reducer The maximum chimney length is 12 metres You can never start with a 90 or 45 bend from the appliance You should always start with 1 metre vertical if the horizontal transit is more than 1 metre You should never start with a cut down pipe from the appliance 16 lt lt faber 11 2 Sample computations Sample calculation 1 Count the horizontal lengths Flue pipe lengths CHE 1 1 Bend D 1x2m Total Count the vertical lengths Flue pipe length A Roof terminal G Total Sample calculation 2 Count the horizontal lengths Flue pipe lengths L 0 5 0 5 Bends K M 2 2m Wall terminal
11. erials such as hollow bricks consult a professional expert 4 5 Mounting the smoke emission outlet materials e Incase of a wall or roof terminal the hole must be at least 5 mm bigger than the diameter of the flue material e Horizontal parts must be installed at a 3 degree slope up away the appliance e Build up the system from the appliance If this is not possible you should make use of a adjustable pipe e For fitting the system a Y metre cut down pipe should be used Make sure the inner pipe is always 2 cm longer than the outer pipe Wall and roof terminal are also shortened These parts must be secured with a self tapping screw e not insulate but ventilate bild in flue material approx 100cm2 4 6 Building a false chimney breast Before constructing the false chimney breast we advise you to perform a function test with the appliance as described in chapter 7 checking the installation 10 lt lt faber 4 7 False Chimney breast e Construct the false chimney breast from non combustible material in combination with metal profiles or of brickwork aerated concrete bricks e Take the grills and the service panel see fig 1 1 an1 2 into account Place a protective shield made of non combustible material above the grills see fig 1 1 A e Always use a lintel if the chimney breast is constructed of brickwork This should not be placed directly onto the appliance 4 8 Frameless without optional decorative sheet
12. nce can only be installed by a competent person in accordance with the Gas Safety We urgently advise you to read this installation manual properly This appliance complies with the guidelines for European gas appliances Gas Appliances Directive and bears the CE mark 2 Safety instructions The appliance should be placed connected and annually checked in accordance with these installation instructions and valid national and local Gas Safety Installation and Use Regulations Check whether the data on the registration plate are in agreement with the local type of domestic gas and pressure The fitter is not permitted to change these adjustments or the construction of the appliance Do not place any additional imitation logs or glowing coals on the burner or in the combustion chamber The appliance has been designed for ambience and heating purposes This means that all surfaces of the appliance including the glass can become very hot hotter than 100 C An exception to this are the bottom of the appliance and the controls Do not place any inflammable materials within a of 0 5 m of the radiation of the appliance and ventilation grills Due to natural air circulation of the appliance moisture and volatile components from paint building materials floor coverings etc that haven t yet set can be drawn through the convection system and can be deposited on cold surfaces as soot That is why you should not use the appliance
13. ng the replacement of the batteries and adjusting the receiver for initial use Hand over to the client o Installation manual o User s manual o Imitation logs instruction card o Suction lifters 14 lt lt faber 9 Annual maintenance 9 1 Service and cleaning e Check and clean if necessary after checking o The pilot light o The burner o The combustion chamber o The glass o The logs for possible fractures o The outlet 9 2 Replace o If necessary the chips embers 9 3 Cleaning the glass Most of the deposits can be removed with a dry cloth You can use ceramic hob cleaner to clean the glass Note prevent fingerprints on the glass these will be burned into it once the appliance is used and cannot be removed anymore Carry out the check up according to the instructions in chapter 7 checking the installation 10 Conversion to a different type of gas e g propane This can only be done by installing the proper burner unit for this purpose get in touch with your supplier Always mention the type and serial number of the appliance when ordering 15 lt lt faber 11 Calculation of flue system The possibilities for the lengths of flue pipes and the possible restrictors have been recorded ina table see chapter 12 This table works with a vertical and a horizontal length To define the vertical length all lengths of flue pipes in a vertical direction should be added up The roof terminal always
14. ould always be accessible Place the gas connection in such a way that this is easily accessible and that before service the burner unit can be disconnected at all times 4 2 Electric connection If an adapter is used for the power supply then a wall socket 230VAC 50Hz must be mounted in the close neighbourhood of the hearth 4 3 Preparation of the appliance e Remove the packaging of the appliance Make sure the gas pipes underneath the appliance are not damaged e Clear a safe space to store the frame and the glass e Remove the frame if necessary and the glass and take the separately wrapped parts out of the appliance e Prepare the gas connection to the gas control valve 9 lt lt faber 4 4 Placing the appliance Take the installation requirements into account see chapter 3 4 4 1 Standing on the floor Place the appliance into the proper position and if necessary adjust the height with the adjustable legs Adjusting the height and leveling the hearth with a spirit level see fig 1 4 e Rough height adjustment o With the extending legs or the long additional legs e Accurate o with the rotating adjustable legs 4 4 2 Suspended from the wall The appliance can be mounted suspended from the wall with the use of the suspension bracket and the Rawlplugs supplied see fig 1 3 These mounting materials are exclusively intended for use on walls constructed of brick or concrete For walls built of other mat
15. rmitted to connect the appliance Measuring the burner pressure Only perform this measurement if the inlet pressure is correct e Open the pressure gauge nipple A see fig 1 7 a few turns and connect a pressure gauge hose to the gas control valve e The pressure must agree with the value indicated on the registration plate In case of deviations get in touch with the manufacturer 13 lt lt faber Close the pressure gauge nipples and check these for gas leaks 7 4 Checking the flame picture Allow the applaince to burn for at least 20 minutes at full and then check the flame picture for 1 Distribution of the flames 2 Colour of the flames If either one or both points are unacceptable then check The positioning of the imitation logs and or the quantity of pebbles or chips on the burner The connections of the Flue materials for leakage in case of blue flames Whether the correct flue restrictor has been mounted The outlet o Wall terminal is installed correctly o Roof terminal is fitted and sited correctly The flue system is correctly calculated 8 Instructing the client Recommend that the appliance be serviced annually by a competent person in order to guarantee a safe use and a long lifespan Advise and instruct the client about maintenance and cleaning of the glass Emphasize the risk of burning in fingerprints Instruct the client about the operation of the appliance and the remote control unit includi