Waveform Recording with WinDaq/Tach
Contents
1. Double click the WINDAQ Tach icon to start the WINDAQ Tach waveform acquisition program 7 WAVEFORM RECORDING WITH WINDAQ Tach e Drag means to press the mouse button and hold it down while you move the mouse then release the button For example Drag down to Data Cursor to enabled the cursor for on screen display Keyboard Conventions e Key names match the names shown on most keyboards and appear in capital letters For example the Shift key appears as SHIFT e A plus sign used between two key names indicates that you must press both keys at the same time For example Press SHIFT Fl means that you press the SHIFT key and hold it down while you press the F1 key e A comma between two key names indicates that those keys must be pressed sequentially For example Press ALT F O means that you press the ALT key and release it press F and release it and then press O and release it e The keys that you use to move around in WINDAQ Tach are referred to as cursor control keys they include the T J and gt keys HOME END PG UP and PG DN STARTING THE WinDag Tach WAVEFORM ACQUISITION PROGRAM To start WINDAQ Tach you must first start Windows From Windows use the mouse to double click on the WINDAQ Tach icon or use the cursor keys to highlight the WINDAQ Tach icon and then press ENTER When successfully invoked WINDAQ Tach displays its default screen The default settings are as f
2. 1 PSI relationship and we expect to measure pressure in the O to 100 PSI range we can expect to measure from 0 to 100 millivolts 0 1 volts with the converter device Therefore we should select a gain that delivers a full scale value no less than 100 millivolts or 0 1 volts From the chart we see a gain of 100 provides exactly this range on the unipolar side of the DI 200 chart So you would configure this channel the channel you are using to acquire the pressure data for a gain of 100 you must be in the SETUP operating mode to configure gain Refer to the AMPLIFIER GAIN CONTROL function in this chapter for complete details b Because the converter device output is going to be 0 to 100 millivolts we should select the unipolar input configuration since our signal will never be negative below zero Select the Full Scale option button in the High Calibrator row and the Full Scale option button in the Low Calibrator row as follows Channel 1 Fixed Calibration High Calibrator Baseline Full Scale Engr Value 5 0000 Click here alibrator C Baseline Full Scale Engr alue 5 0000 Next Previous Cancel 96 WAVEFORM RECORDING WITH WINDAQ Tach c From the chart at a gain of 100 the full scale value is O volts and the full scale value is 100 millivolts Since we will be measuring O0 to 100 millivolts O is ideal for the low calibrator value enter 0 in the Low Calibrator Engr Value box and 1
3. Soe User Annotation AIF 11 aul oes a Insert Mark Ctrl Space SEP OF aap Frame Rate Insert Commented Mark Shitt Space l Masimum Sample Aate Compression Fr Event Mark Capacity Compression 42 Page Up Open New File on Full Compression 2 Page Down Record Next File on Full Location Alt Shitt O eae Typa Tachometer Alt T E Broadcast Sync Messages Exit on Full View Scaling Assign Channel Limits Show Dynamic Range Assign Range Alt F Forward Range Ctrl Down Grow 2 Up Backward Range Ctrl Up Shrink 2 ee Format Screen 1 Waveform Shift Invert Ctrl 2 Wavetomes overlapped Shift 2 Next Palette Alt P Dee Shift Waveform Down 1 Fisel Gray Previous Palette Alt Shift eP aes i Waveform Down 10 Pirels Ctrl Gray ae 4 Wavetomes overlapped Shift d User Palette Ctrl U i Waveform Up 1 Fisel Grap pital cate eis Waveform Up 10 Pixels Chrl Gray ToolBox Ctrl T Oo waveforms overlapped Shift 6 5 6 Waveforms Shift Analog Plat Alt S hitt hy 16 Waveforms overlapped Shift s Digital Plot Alt S hift T 16 Waveforms Shift 9 a2 Waveforms overlapped Shift 0 User specitied format Shift Options Help Contents Current Data Data Display Kepboard Limit Display Alt L Mouse Search for Help n Grids Alt a l l Hom to Use Help Grid Spacing Chrl G User Annotation Alt U About WinDag Acquisition Scroll Mode Ctrl
4. The following describes how each is connected to a DI 720 or 730 in a variety of different configurations For the DI 720 Only ae AST AU es See rrr EET ET a Poe TEET DI 720 Series p ey J DATA ween F AES PCE ue glr a ele h Lh D A a You can connect the digital inputs to the auxiliary connector circled of the DI 720 The tachometer input connects to DI1 Pin 6 and the direction input connects to DIO Pin 25 For the DI 720 and 730 Both the DI 720 and 730 can be accessed through their expansion port connector by using adapter cable 100679 This cable provides the necessary mating connector for the expansion output and a standard 37 pin D sub connector on the other end that matches the auxiliary connector of the DI 720 circled Once the cable is connected to the expansion port the pinout on the D sub end will be the same as with the DI 720 tachometer input connects to DI1 Pin 6 and direction input connects to DIO Pin 25 For the DI 720 and 730 with DI 75B or DI 725 Expander Units Both the DI 720 and 730 can be expanded with DI 75B or DI 725 expander units All expander units have connectors labeled Expansion In and Expansion Out An expansion cable always connects the expansion port connector to the Expansion In connector on the expander unit Regardless of the number of expander units you use there will always be an Expansion Out connector available on the last unit You will need to c
5. but on the waveform s rising slope Selecting the option button triggers the display to start at the trigger level but on the waveform s falling slope Select the trigger slope by D Clicking the desired option button When a slope is selected a dotted box surrounds the slope name and a dark dot appears in the slope option button Y Pressing the TAB key until one of the two slope options becomes selected When selected a dotted box surrounds the slope name and a dark dot appears in the slope option button At this point the T or J cursor control keys can be used to select the desired slope Channel text box Allows you to specify or select a channel for the trigger source 50 WAVEFORM RECORDING WITH WINDAQ Tach Level field Indicates the current trigger level in volts Free Run check box Allows you to select between a triggered sweep oscilloscope display or a free running oscilloscope display see discussion above Note that this box must be unchecked to set the trigger level Erase Bar check box Allows you to enable disable the display of the vertical erase bar cursor on the waveform Whether the erase bar is displayed or disabled the waveform information screen is still erased and replaced with a fresh sweep of data OK command button Allows you to close the Oscilloscope Triggering dialog box and apply the just configured display trigger conditions Set Level command button Allows you to adjust or set
6. of the selection rectangle will dictate the amount of waveform contraction 2 Click the right mouse button in the right or left annotation margin The waveform in the strip will be shrunk to fit within the vertical limits of the selection rectangle Choose Scaling Shrink 2X ALT C S This contracts the specified waveform one half its original size in the amplitude direction Movine the specified waveform down in the stri Click the Shift Waveform Down button in the ToolBox D Point to the Scaling menu and drag down to Waveform Down 1 Pixel or Waveform Down 10 Pixels Waveform Down 1 Pixel moves the specified waveform down a single pixel in the strip and Waveform Down 10 Pixels moves the specified waveform down 10 pixels in the strip OR 1 Drag in the waveform strip area to draw a selection rectangle around a portion of the waveform The size of the selection rectangle does not matter it is merely used to represent the current horizontal position of the waveform on the screen 2 With the mouse pointer positioned inside the selection rectangle drag the selection rectangle down to move the specified waveform down in the strip to the desired position within the limits defined by the A D converter Y Choose Scaling Waveform Down 1 Pixel or Scaling Waveform Down 10 Pixels ALT C O or ALT C D respectively Waveform Down Pixel moves the specified waveform down a single pixel in the strip and Waveform Down 10
7. screen is a function of the data points or A D readings being acquired During the plotting process in a much simplified overview previous and current A D readings are evaluated These evaluations eventually define the end points of what will be a vertical line segment Once the end points are defined a vertical line is drawn to connect them It is this line segment and many more just like it drawn adjacent to each other on the screen that eventually produces a real time waveform display When compression equals 1 no compression applied to the waveform every single A D reading is plotted The majority of CPU time is devoted to the display of data on your screen As you might have guessed that can be an overwhelming task for your computer when a high sample rate 1 e 50 000 samples per second is selected This is the disadvantage of an uncompressed waveform at higher sample rates the real time display cannot plot the A D evaluations as fast as the CPU is supplying them resulting in a fast jerky display showing only choppy intermittent waveform information When compression is applied to the waveform multiple A D readings equal to the compression factor are evaluated to define the end points of a line segment In this instance less CPU time is required for the display For example if compression equals 100 then 100 consecutive A D readings are evaluated to define the end points of a line segment The advantage of compression is that
8. 2 windows non overlapped 2 4 4 windows overlapped 4 5 4 windows non overlapped 4 6 8 windows overlapped 8 7 8 windows non overlapped 8 8 16 windows overlapped 16 9 16 windows non overlapped 16 10 32 windows overlapped 32 11 User specified format 32 As you review the following illustrations keep these points in mind 1 A waveform channel is always assigned to a display window as indicated by the X Y annotation in the left right annotation margin X designates the display window and Y designates the waveform channel However using the VARIABLE WAVEFORM ASSIGNMENT function you can assign any waveform to any given window What s more you can display any block of consecutive display windows on your monitor with the ASSIGN RANGE function Keep in mind that nothing about the display format is fixed The default is channel 0 assigned to window 1 channel 1 assigned to window 2 etc 2 The particular display format enabled at any given moment simply affects the way you view the waveforms being acquired It in no way affects information being stored to disk during data acquisition 3 Each display format may be selected on the fly through simple keystrokes fully described in this manual 4 Any data acquisition channel number may be assigned to any waveform window as an overlapping or non overlapping display and as a function of the enabled display format This waveform window waveform channel assignment capability is available
9. 3931 f AC a A f 1 0 Volt Fi i f 1 18662 S s CHAN 500 40 Status SET UP 4 The offset waveform When the left mouse button was released the waveform was vertically offset by the amount the rectangle was dragged within the limits of the A D converter s dynamic range Note the waveform s numerical values in the left annotation margin reflect the new position 14 WAVEFORM RECORDING WITH WINDAQ Tach Scaling a Specified Channel s Waveform File Edit View Scaling Options Help Mode Scroll Channels 0 1 2 3 57S F3 2000 Compress F7 1 storage used 0636 E a pbc ce ee oe re Ai i ff 7 F se Vda ane AR V 57s CHAN 500 m DI V 40 Status SET UP 1 The original waveform The object is to scale a small section of waveform so it fills the entire strip area thus allowing the small section to be examined in greater detail Again note that the 1 0 annotation in the left annotation margin is highlighted indicating window 1 is enabled for adjustments File Edit View Scaling Options Help Mode Seroll Cranrels M1 2 3 ars F3 2000 Compress F7 1 storage Z used 0638 Started here ote let 1 0 viale h EEE as CHAN 500 m DIV 40 a pawns eel WP 2 Drag the left mouse button to draw a selection rectangle Once again the size of the rectangle is immaterial In this example it was drawn on the very tip of the waveform because this is the area of interest that we would like
10. F Oscilloscope Mode Fast Scroll Pause Graphics AlteF1 Beep on File Full 18 Menu File Edit WINDAQ Tach COMMAND HIERARCHY Command Open Open Reference File Close Save Default Setup Record Stop Browse Freeze Exit Undo Copy Sample Rate Channels Channel Settings Low Calibration High Calibration Fixed Calibration User Annotation Insert Mark Insert Commented Mark Compression Compression x2 Compression 2 Location Tachometer Preferences WAVEFORM RECORDING WITH WINDAQ Tach Command Options Accelerator key s CTRL O F4 CTRL F4 Alt J Ctrl F CTRL Z CTRL C F3 F5 F10 F9 F11 F12 F11 CTRL Space SHIFT Space F7 Page Up Page Down Alt Shift O Alt T Update Interval Scroll Limit Skip Factor Buffer Size Beep on Gap Frame Rate Maximum Sample Rate Event Mark Capacity Open New File on Full Record Next File on Full Thermocouple Type Not functional in WinDaq Tach New Password Broadcast Sync Messages Exit on Full 19 Reference 4 18 4 61 4 40 4 44 4 21 4 21 4 74 4 93 4 43 4 79 4 4 4 32 4 102 4 103 4 97 4 94 4 55 4 55 4 106 4 107 4 107 4 52 4 78 4 66 4 67 4 68 4 69 4 69 4 70 4 70 79 4 7 4 7 4 72 WAVEFORM RECORDING WITH WINDAQ Tach Menu View Scaling Options Help Command Command Options Assign Channel Assign Range Forward Range Backward Range Fo
11. If you are not satisfied with the color scheme you can repeat steps 3 through 5 to get the desired colors or you can highlight the Cancel command button and press ENTER to get back to the original palette you started with User Palette Dialog Box The user palette dialog box gives you the ability to manipulate the display palette color schemes The following information can be referred to when using the User Palette 61 WAVEFORM RECORDING WITH WINDAQ Tach User Palette x Palette Increment Decrement Background EESIN E E Grid Lines and User Annotation zi Breer HEE BSS Palette _ Serves as a label or identifier for the selected color scheme Range is from 0 to 15 Increment command button Allows you to display the color scheme that defines the next palette Activating this button increments the Palette and updates the background waveform and grid lines and user annotation color selection bars The colors surrounded by dotted boxes on the selection bars indicate what the palette will look like when the Apply command button is activated Consecutive activation of this button displays all 16 palette selections updating the color selection bars and palette with each activation Decrement command button Allows you to display the color scheme that defines the previous palette Activating this button decrements the Palette and updates the background waveform and grid lines and user annotation colo
12. To do this you must either modify the existing WINDAQ Tach program item or create a new program item and name it WINDAQ FAST START WINDAQ AUTO RECORD or anything similarly appropriate To implement the auto record feature 1 Click the right mouse button on the Start button in the taskbar 2 Click Open This displays the Start Menu window For the next step you must decide whether you will create a new shortcut or modify the existing program item If you wish to create a new shortcut continue with step 3 below If you wish to modify your current WINDAQ Tach program item skip to step 4 of this procedure 3 To create anew shortcut a In the Start Menu window click on File point to New and click on Shortcut The Create Shortcut dialog box appears b In the Command Line box type d path di200tnt exe d path targetfilename filesize F d path setupfile A Where items in brackets are optional d path is the drive and directory where file di200tnt exe resides d path targetfilename is the name of the data file including optional drive path and extension specifiers to which WINDAQ Tach is to store data the target file filesize is an optional number that specifies the maximum file size of the target data acquisition file If not specified the filesize defaults to 360 kb The minimum size that may be specified is 1 156 bytes which is equivalent to the size of the WINDAQ Tach file header The maxi
13. V F In the format box select the desired display format with T or J keystrokes 3 Press ENTER NO me It is possible to display a format design other than the standard display formats listed For example suppose you wanted to monitor three waveforms on the screen Your best choice among the standard display formats capable of displaying at least three waveforms is the four waveform format However the fourth displayed waveform would be blank It would simply occupy screen space without conveying any useful information The tool used to devote the entire window to the exact number of waveforms you wish to monitor is called the User specified format option To use the User specified format option DO 1 Point to the View menu and drag down to Format Screen In the format box click User specified format Choose View Format Screen ALT V F In the format box select User specified format with T or J keystrokes 3 Press ENTER NO e This displays the User specified dialog box as follows Screen Format Number of Channels A C Overlapped OK Cancel When the User specified dialog box is first displayed a blinking vertical line called the insertion point appears behind the number in the Number of Channels text box This insertion point indicates the active area of the dialog box the next action you perform will occur in this area To specify a non standard format DO 1 Enter the desired number of
14. WAVEFORM RECORDING WITH WINDAQ Tach SHOW DYNAMIC RANGE FUNCTION Allows you to see the waveform file with respect to the entire dynamic range of the A D converter Activating this function modifies the vertical scale and automatically adjusts the waveform so the and full scale counts are placed at the top and bottom of the waveform strip An A D converter operates in terms of counts If X represents the bit resolution of the A D converter then the full scale limit is 2 amp 1 1 counts and the full scale limit is 2 1 counts For example if you have a 12 bit A D converter the full scale limit is 2047 counts and the full scale limit is 2048 counts By seeing the waveform with respect to the entire dynamic range of the A D converter you see how much of this range you are using Ideally the waveform should use the entire dynamic range of the A D converter in order to take full advantage of its resolution ACTIVATING PROCEDURE Point to the Scaling menu and drag down to Show Dynamic Range Y Choose Scaling Show Dynamic Range ALT C R This modifies the vertical scale and automatically adjusts the waveform to place the and full scale A D converter counts at the top and bottom of the waveform strip thus showing you the waveform file with respect to the entire dynamic range of the A D converter SPECIAL CONSIDERATIONS Subsequent activations of the Show Dynamic Range command does nothing the function does not togg
15. While in this mode all data acquisition features and functions are available with some restrictions except the following all channel specific operations i e channel number type gain offset sample rate adjustments and REMOTE CONTROL features In this mode waveform information is being continuously streamed to disk while the real time display remains active When in this mode the Status area of the bottom annotation line displays RECORD The STANDBY operating mode becomes active when waveform recording to disk is temporarily suspended by choosing the Stop command While in this operating mode all data acquisition features and functions are available except Channel specific operations i e channel number type gain and offset and Sample rate adjustments In this mode only the real time display is active data acquisition to disk has been stopped When in this mode the Status area of the bottom annotation line displays STBY 21 WAVEFORM RECORDING WITH WINDAQ Tach WINDAQ Tach GENERAL INFORMATION INSTALLATION To install WINDAQ Tach software under Windows 98 2000 or ME insert the floppy and click Start Run Type A NEW_TCH EXE before pressing Enter DIGITAL INPUT WINDAQ Tach uses two digital input lines of the DI 720 or 730 one for detecting forward backward direction and the other for detecting distance Both are assumed to be TTL compatible signals The distance signal is further assumed to be a pulse train tachomet
16. a file size remember that one sample stored to disk requires two bytes F d path setupfile is an optional previous data acquisition file including optional drive path and extension specifiers created by WINDAQ Tach that when specified forces WINDAQ Tach into exactly the same configuration as setupfile Virtually all data acquisition parameters are ported from the setup file to become the default conditions of the new data acquisition file specified by d path filename ext Such parameters include but are not limited to the number of channels and type enabled scaling constants engineering units display format compression display mode DAC offsets and gain The purpose of the setup file is to allow instantaneous setup for similar but separate data acquisition runs A is the switch that forces WINDAQ Tach to immediately start acquiring data to disk upon Start up Examples of syntax a C WINDAQ DI2Z00TNT EXE TEST1 DAT A b TRIALI A c C WINDAQ DI200TNT EXE TEST1 DAT 200K Fdata dat A c Click the Next gt button The Select a Title for the Program dialog box appears d In the text box type a name for the new shortcut Choose something that uniquely identifies it as an immediate start application This name will become the label that appears under the shortcut icon in the Start Menu window e Choose the Finish button The dialog box closes and the new shortcut icon appears in the Start Menu window You can n
17. are only provided to configure the real time display EXAMPLE Accelerator key Version Assumes eight waveform channels are available KEYSTROKE ONE KEYSTROKE TWO COMMENT 1 T Expand window one s waveform 2X original size 4 Contract window one s waveform by a factor of 2 CTRL Gray Move the waveform in window one down 10 pixels Gray Move the waveform in window one up 1 pixel 4 Gray Move the waveform in window four down 1 pixel 5 Contract window five s waveform by a factor of 2 8 CTRL Gray Move the waveform in window eight up 10 pixels 107 DATAQ INSTRUMENTS DATAQ Instruments Inc 241 Springside Drive Akron Ohio 44333 Telephone 330 668 1444 Fax 330 666 5434 E mail support datag com Direct Product Links click on text to jump to page Data Acquisition Data Logger Chart Recorder Thermocouple Oscilloscope
18. channels to be displayed up to 16 overlapped and click OK You also have the option of overlapping the specified number of waveforms To overlap the waveforms click the Overlapped check box An X appears in the box indicating an overlapped format A subsequent click removes the X indicating a non overlapped format Y 1 Enter the desired number of channels to be displayed up to 16 overlapped and press ENTER You also have the option of overlapping the specified number of waveforms To overlap the waveforms press the TAB key until a dotted box appears around Overlapped then press the space bar An X appears in the Overlapped check box indicating an overlapped format A second press of the space bar removes the X indicating a non overlapped format 47 WAVEFORM RECORDING WITH WINDAQ Tach SPECIAL CONSIDERATIONS The number of channels you will see displayed on your screen is a function of monitor resolution A 640 x 480 display may not be able to display all 32 channels if selected however a 1024 x 768 display will show all 32 channels when enabled The following describes each display format in terms of its window design maximum number of displayed channels and enabling keystrokes FORMAT WINDOW MAXIMUM ENABLING NUMBER DESIGN CHANNELS KEYSTROKES One 1 full screen window 1 ALT 1 Two 2 full screen windows 2 ALT 2 overlapping waveforms Three 2 windows 2 ALT 3 Four 4 windows 4 ALT 4 overlapping waveforms Five 4 windows 4
19. click the Commented Event Marker button in the ToolBox D While in the RECORD operating mode point to the Edit menu and drag down to Insert Mark for an uncommented event marker or Insert Commented Mark for a commented event marker Y While in the RECORD operating mode choose Edit Insert Mark for an uncommented event marker or Edit Insert Commented Mark for a commented event marker A commented event marker allows you to enter up to a 39 character comment that will be associated with the event marker When Insert Commented Mark is chosen from the Edit menu or when the Commented Event Marker button is clicked in the ToolBox the Event Marker Comment dialog box is displayed as follows Event Marker Comment x Event Comment Doo O cnet Enter the desired comment up to 39 characters in the text box The comment will be displayed with its associated event marker by the SEARCH FOR EVENT function of the WINDAQ Waveform Browser playback software package A commented event marker is anchored at its position in the data file the instant the event marker function is enabled Data acquisition to disk continues while you enter your comment If the Cancel command button is chosen while recording the event marker will not be deleted from the data or trailer file but the comment will be blank If the Cancel command button is chosen while not recording the comment will be applied to the start acquisition marker generated automatically when
20. differential or digital operation When this button is activated on instruments with 16 channels or less the flashing Ch _ block cursor is displayed in the status bar following the Channels field A single ended channel is enabled by entering the channel s number and pressing the ENTER key A differential channel is enabled by entering the channel number followed by the letter D e g 3D and pressing the ENTER key A digital channel is enabled by entering the channel number followed by the letter I e g 4I and pressing the ENTER key Pressing any key other than a number key the D key or the I key exits channel configuration To remove a channel activate the tool button type a minus sign followed by the channel number and press ENTER e g 4 removes single ended channel 4 When this button is activated on instruments with more than 16 channels the channel selection grid is displayed Refer to Appendix B or Appendix E for channel enabling details on these instruments This button is the same as choosing Channels from the Edit menu Refer to the Configure ADC Channels Function for complete details Channel Setup Allows you to select gain and unipolar bipolar measurement range on a channel by channel basis Since these parameters can be set per channel the desired channel must be selected A channel is selected by clicking the left mouse button in the desired channel s annotation margin when
21. each time the command is selected SPECIAL CONSIDERATIONS Note that you are not limited to the color combinations presented on the 16 pre defined display palettes It is possible to tailor one several or all palettes to suit your color preference taste or requirements The tool used to accomplish this is the User Palette command The User Palette command allows you to redefine the palettes color scheme by selecting different background gridlines and user annotation or waveform colors from among 16 color choices When a palette is changed you have the option of making the new color scheme permanent or canceling all color changes If the changes are canceled the palette reverts back to the original color scheme you started with If the changes are made permanent the new color scheme is saved as one of the 16 display choices and the original color combinations are overwritten To change a palettes color scheme proceed as follows D 1 Using the techniques described above display the palette you want to change 60 WAVEFORM RECORDING WITH WINDAQ Tach 2 Point to the View menu and drag down to User Palette or click the Change Palette button in the rent ToolBox This displays the Palette dialog box 3 In the Palette dialog box click the Background Grid Lines and User Annotation Ist Waveform or 2nd Waveform colors you want A dotted box appears around the selected color sample 4 Click Apply to apply the color
22. for the signals becomes the same as the DI 720 Using WINDAQ Tach you will be able to perform the following functions e Record waveform data to disk in the background while running any combination of programs in the foreground e Annotate your data with descriptive event marker comments even while recording to disk e Monitor the real time display in a smooth scroll or triggered sweep mode of operation scaled to any unit of measure e And much much more This manual covers the WINDAQ Tach waveform acquisition package for Windows and is intended for users of all proficiency levels The reference information at the beginning of this section describes how to start the WINDAQ Tach waveform acquisition package what you will see when in WINDAQ Tach and how to navigate within WINDAQ Tach After this reference information each acquisition command or function is described in detail To help you find the information you want the reference information contains a menu hierarchy with page references Also included is a chart cross referencing commands with menus WAVEFORM RECORDING WITH WINDAQ Tach Required Hardware Connections WinDaq Tach software requires two digital inputs one for tachometer and a second for direction Digital inputs DIO and DI1 on the auxiliary IO connectors of DI 720 and 730 series products are reserved for these connections DIO connects to a TTL level direction signal and DII connects to a TLL level tachometer signal
23. icons DI 720 Acquisition abd Window title The window title contains the WINDAQ Tach utility name and the currently active data storage file name Window sizing icons The window sizing icons provide a fast convenient way to reduce enlarge close or return the window to its previous size Selecting one of these icons with the mouse performs that action Menu bar Like other Windows applications WINDAQ Tach contains a menu bar The commands available in WINDAQ Tach are grouped on menus These menus appear in the bar across the top of the window and represent the heart of the WINDAQ Tach waveform acquisition package Eile Edit Miew Scaling Options Help With these menus you can apply the powerful waveform acquisition capabilities of WINDAQ Tach To choose a command from a menu you can either point to the desired menu and click or press the ALT key and then the underlined letter of the desired menu This causes the commands available on that menu to be pulled down or displayed Once displayed the commands on the pull down menu 9 WAVEFORM RECORDING WITH WINDAQ Tach Status bar can be chosen and thus performed by clicking on the desired command or by pressing the underlined letter in the desired command Also provided on the pull down menus are keyboard shortcuts or accelerators Accelerators are function keys or combinations of keys displayed next to the menu item that when pressed immediately invokes the desired ac
24. is enabled To enable current waveform data if disabled or disable it if enabled D Point to the Options menu and drag down to Current Data Choose Options Current Data ALT O C When the current data option is enabled the annotation margin will have the following appearance and a check mark V will be displayed on the Options menu immediately preceding the Current Data command Data cursor vertical line DI 720 Acquisition Current waveform E value at cursor position oa ey 04 Compress 3 Current data enabled shown in oscilloscope mode Data Display This option allows you to enable disable the display of data or base line values in the annotation margin If Limit Display is not enabled the engineering units will toggle on and off along with the value To enable the data display if disabled or disable it if enabled D Point to the Options menu and drag down to Data Display Choose Options Data Display ALT O D When the data display option is enabled the annotation margin will have the following appearance and a check mark V will be displayed on the Options menu immediately preceding the Data Display command 78 WAVEFORM RECORDING WITH WINDAQ Tach File Edit View Scaling Options Help Osacillloscope Channels 0 1 2 3 E Data display enabled aS 1010 04 Lom F lt Storag 2 4 used Pramnes s 18 18 Limit Display This option allows you to enable disable the display of upper and lower chart e
25. limits of O to 100 mmHg or 200 mmHg to 200 mmHg or whatever is desired Note that a channel spanning 0 200 mmHg is much easier to read and interpret on a per division basis than one that spans 10 372 189 628 mmHg To specify convenient upper and lower chart edge values 1 Select Scaling Limits as follows Point to the Scaling menu and drag down to Limits Y Choose Scaling Limits ALT C L When selected the Display Limits dialog box is displayed on the screen as follows 100 WAVEFORM RECORDING WITH WINDAQ Tach Top Limit 5 0000 Bottom Limit 5 0000 Next Previous Cancel 2 Using the same procedure as before type convenient top and bottom chart edge values in their respective text boxes The Next and Previous command buttons allow you to step through all of the enabled channels in order entering the desired display limits for each channel without closing this dialog box Note that when either the Next or Previous button is activated the channel number in the title bar of the dialog box changes to indicate the channel for which you are currently setting display limits 3 Complete the chart edge value entry as follows Click OK Press the TAB key until a bold border surrounds the OK command button indicating selection and press ENTER Your specified values will now be displayed on the upper and lower chart edges and the waveform will be automatically scaled to fit the new values SPEC
26. or otherwise communicate with WINDAQ Tach through Windows without preventing user interaction For complete slave mode details contact technical support EXAMPLE Accelerator key version KEYSTROKE COMMENT CTRL O Assign a file name and size F4 Start acquiring data from the RECORD operating mode Status indicates RECORD CTRL F4 Stop acquiring data Status indicates STBY F4 Start acquiring data from the RECORD operating mode Status indicates RECORD 32 WAVEFORM RECORDING WITH WINDAQ Tach AMPLIFIER GAIN CONTROL FUNCTION nonfunctional when used with serial port instrumentation FUNCTION Allows the selection of channel by channel gain and measurement range If you are using an EXP Series analog channel multiplexer refer to Appendix B for gain control function details ACTIVATING PROCEDURE Gain To select channel by channel gain you must be in the SET UP operating mode Gain cannot be adjusted once the RECORD mode has been entered Additionally the desired channel must be enabled An analog channel is enabled for gain adjustments by D Clicking the left mouse button in the unselected channels annotation margin Typing the number or letter of the display window that contains the waveform to be adjusted The focal point for enabling any waveform for any type of adjustment is the variable waveform assignment indicator of each channel This is the two element equality X Y displayed for every enabled ADC channel Elemen
27. selected a highlighted box surrounds the X Y annotation in the margin When this button is activated the Channel X Settings dialog box appears with the selectable gain factors and resulting and full scale voltages To select a gain simply click on it and choose the OK command button To specify unipolar measurement range click the Unipolar check box To specify bipolar measurement range leave the Unipolar check box unchecked This button is the same as choosing Channel Settings from the Edit menu Refer to the Amplifier Gain Control Function for complete details Calibration Allows you to calibrate the waveform in any significant engineering units using the fixed calibration method When this button is activated the Fixed Calibration dialog box appears prompting you to enter calibration values This button is the same as choosing Fixed Calibration from the Edit menu Refer to the Waveform Calibration Fixed Method Function for complete details 86 WAVEFORM RECORDING WITH WINDAQ Tach Sample Rate Allows you to specify a sample throughput rate for data recording When this button is activated the Sample Rate dialog box appears prompting you to specify the desired throughput rate or total scanning rate in samples per second For example if you wanted to record two channels one at 40 Hz and the other at 90 Hz you would enter a throughput rate of 130 in the text box This button is the same as choosing Sample Rate from t
28. the high calibration data value that is to be assigned to the input voltage level For instance referring back to our previous examples a For the case where the transducer output is known we would enter 100 in the High Cal Value text box 4 5 in the Input Level text box and PSI in the Engr Units text box b For the case where the transducer output is unknown we would also enter 100 in the High Cal Value text box ignore the Input Level text box WINDAQ Tach has established the input voltage level for you and enter PSI in the Engr Units text box Again you use the TAB key to position the insertion point in the various text boxes Type up to a four character optional engineering unit tag i e PSI f s rpm etc 2 Complete the high calibration entry as follows Click OK Press the TAB key until a bold border surrounds the OK command button indicating selection and press ENTER The High Calibration dialog box disappears and the waveform channel displays all waveform data values calibrated in the chosen engineering units If desired the upper and lower grid limit values may be specified and the waveform automatically scaled to fit This feature allows the channel s full scale display span to be shown in whole numbers rather than obscure fractional values which sometimes result from calibrating For example a waveform scaled in mmHg can be automatically expanded or contracted to fit within grid
29. the trigger level Note that the Free Run check box must be unchecked to set a trigger level When selected the Oscilloscope Triggering dialog box closes and causes the cursor to point to a short horizontal line at the right side of the annotation margin This short horizontal line is the trigger level indicator File Edit View Scaling Options Help Mode Triggered Channels 0 1 es F3 2000 Compress F 7 1 S a EN 2 2449 SEE volt Trigger level indicator 5 anon S s CHAN 1000 m DIV 20 At this point the mouse is limited to dragging the line up or down to the desired trigger level Note that when the mouse is moved the data display in the left annotation margin changes to indicate trigger level in volts When set where desired clicking the left mouse button sets a new trigger level while clicking the right mouse button retains the existing level Note that if the trigger level is set somewhere above or below the current signal the signal will disappear from the display Cancel command button Allows you to close the Oscilloscope Triggering dialog box and cancel any changes made to trigger conditions provided that the changes were not saved with the OK command button SPECIAL CONSIDERATIONS If the display is paused while in the Record operating mode data acquisition to disk continues unimpeded The trigger level is saved as a digital A D converter value so the associated level in engineering units will change if the c
30. two different ways to calibrate your waveform the fixed calibration method and the high low calibration method Either method will produce the same results however one method may be preferable or easier to use over the other because of the nature of the signals being acquired and or what is known about the transducers used to acquire these signals Without calibrating waveform data is scaled annotated and displayed in volts which in many cases is not very meaningful Calibration is used to give meaning to the displayed data Instead of volts your data can be scaled annotated and displayed in significant engineering units 1 e PSI RPM Ibs ft s etc Calibration is done primarily for display purposes it makes the data more visually appealing and easier to understand on your monitor However when data is recorded or acquired to disk it is not completely independent of this calibration information you have provided When data is recorded it is stored to disk in a data file in the form of A D converter counts These A D converter counts are stored in a data file regardless of whether you provided calibration information or not However when you calibrate the calibration information is saved in an accompanying header file while your data is being stored in the data file This header file saves the calibration information allowing it to be re used when you review the data in WINDAQ Waveform Browser or if you append data to the same acquisitio
31. window and activate the How to Use Help category 56 WAVEFORM RECORDING WITH WINDAQ Tach INVERT FUNCTION FUNCTION Allows you to flip the selected waveform upside down exchanging the top and bottom limits ACTIVATING PROCEDURE Point to the Scaling menu and drag down to Invert Choose Scaling Invert ALT C I SPECIAL CONSIDERATIONS None ACCELERATOR KEY EXAMPLE KEYSTROKE COMMENTS CTRL I Flips selected waveform upside down CTRL I Flips selected waveform back to its original orientation 57 WAVEFORM RECORDING WITH WINDAQ Tach LOCATION FUNCTION Allows you to change the location and specify whether it should increment or decrement on forward pulses from the tachometer ACTIVATING PROCEDURE Point to the Edit menu and drag down to Location Choose Edit Location ALT E L If you desire to have a starting point other than 0 kilometers the desired starting point can be entered in the location dialog box and subsequent tachometer pulses will increment or decrement starting at this offset In the following dialog box an offset of 12 11839 kilometers has been defined Location Location 12 11839 Decreasing Forward EER SPECIAL CONSIDERATIONS This command may not be used while storing to disk but may be changed after File Stop returns the status to STBY Cancel ACCELERATOR KEY EXAMPLE KEYSTROKE COMMENTS Alt Shift O Edit current location 58 WAVEFORM RECORDING WITH WINDAQ
32. 0 372 189 628 mmHg While acquiring data continuously to disk the waveform strip area maintains a real time display of the acquired waveforms The real time display provides the most flexible and functional waveform display available It allows you to maintain complete control over data acquisition parameters in real time through mouse and or keyboard features Control sample rate waveform compression the number of channels enabled event markers disk storage and much more 1 WAVEFORM RECORDING WITH WINDAQ Tach Bottom The bottom annotation line consists of three elements the equivalent per channel sampling rate the annotation distance per grid division and the current operating mode line Equivalent Distance per arid Current per channel division operating sampling rate mode Equivalent per channel sampling rate The equivalent per channel sampling rate is derived by dividing the selected sample throughput rate displayed in the S s F3 field of the status bar by the number of channels enabled Distance per grid division The distance per grid division is a function of the selected sample rate the number of channels enabled and the selected waveform compression factor The grid on the display provides a convenient distance reference for the display in meters per division Current operating mode The current operating mode field displays one of the three data acquisition operating modes SET UP RECORD or STBY DR
33. 00 is ideal for the high calibrator value enter 100 in the High Calibrator Engr Value box Then specify significant units in this case PSI in the Engr Units box All of the acquired data will be within this range and calibrated in PSI rather than volts The following illustration depicts our calibrated screen display Units Given 1 mV PSI Volts 100 PSI FS Full scale 0 1V 100 mV 50 PSI BL Baseline 0 05V 50 mV 0 PSI FS Full scale OV EXAMPLE Accelerator key Version KEYSTROKE COMMENTS 1 Select the window to receive engineering unit data F12 Prepare to enter high calibrator value 500 Enter high calibrator value TAB Prepare to enter low calibrator value 500 Enter low calibrator value o F degrees Fahrenheit Enter engineering unit tag ENTER Complete the fixed calibration entries 97 WAVEFORM RECORDING WITH WINDAQ Tach WAVEFORM CALIBRATION HIGH LOW METHOD FUNCTION WINDAQ Tach offers two different ways to calibrate your waveform the fixed calibration method and the high low calibration method Either method will produce the same results however one method may be preferable or easier to use over the other because of the nature of the signals being acquired and or what is known about the transducers used to acquire these signals Without calibrating waveform data is scaled annotated and displayed in volts which in many cases is not very meaningful Calibration is used to
34. 050000 Last Point 1000 0050000 0050000 7 Maximum Minimum Input Type Linear C Unipolar amp Nonlinear E Fahrenheit amp Thermocouple Reset Cal Cancel Next Previous The gain factors you see displayed at the top of this dialog box are hardware dependent Gain factors will be different depending on your instrument Displayed next to each gain are the equivalent plus and minus full scale voltages that result from selecting that gain factor To specify a gain D Click on the desired gain factor Y 1 Press the T or J arrow key until the desired gain factor is highlighted 2 Press ENTER Unipolar Bipolar Measurement Range Option Not applicable to WINDAQ Tach software Reset Cal Command Button Whenever the gain or unipolar bipolar setting is changed in this dialog box confirmed by selecting the OK command button any calibration to significant engineering units is preserved and adjusted to reflect the new gain or unipolar bipolar setting However the screen scaling for the selected channel is restored to the default values shown next to the gain factor so that the top and bottom screen limits show the extremes of the A D converter input range Selecting the Cancel command button cancels any proposed changes thus keeping previous limits intact Selecting the Reset Cal command button allows you to reset the selected channel from a significant engineering units calibration back to
35. 2 In the Edit Preferences submenu click Open New File on Full Y Choose Edit Preferences Open New File on Full ALT E P O When enabled a check mark V is displayed on the Edit Preferences submenu immediately preceding the Open New File on Full command 69 WAVEFORM RECORDING WITH WINDAQ Tach Next File on Full Enables disables the ability to automatically close a full file enter a new file name and start recording another new file For example say you are acquiring data and the file becomes full much sooner than you anticipated yet you still need more data If this preference is disabled you would have to close this full file and then select the Open command from the File menu to name and open a new file thus continuing the acquisition session but losing data while doing all of the file manipulating If this preference is enabled the last character of the old filename is automatically incremented when full and recording is started automatically to this new filename If this new file is allowed to become full the last character of this new filename is decremented effectively getting you back to the file you started with and recording automatically continues thus overwriting the old data file Recording continues alternately between this pair of files until it is stopped by the user For example suppose this preference is enabled you are acquiring data to a file called RAT WDQ and it is approaching full size When full recordi
36. 2000 Caaereee Fy Sterise uae fe CHAS 500 m Dv 40 Stathe SET UP 2 DES E ee ee 1 The original waveform The object is to offset the waveform from its current position to a position centered on the screen Note that the 1 0 annotation in the left annotation margin is highlighted indicating window is enabled for adjustments File Edit View Scaling Options Help Mode Scroll Channels 0 1 2 3 5 s F3 2000 Compress F 7 1 storage 4 used Jp 7369 1 0 olt Started here 50 bea S s CHA amp AN 500 m DIV 40 status SET UP 2 Drag the left mouse button to draw a selection rectangle The size and placement of the rectangle is immaterial In this example it was drawn to approximate the vertical limits of the waveform so it could be accurately centered at the center of the screen Note that the rectangle remains fixed in size when the left mouse button is released 13 WAVEFORM RECORDING WITH WINDAQ Tach File Edit View Scaling Options Help Mode scroll Channels 0 1 2 3 ees Way 2000 Compress F7 1 6250 storage Z used ie S e CHAN 500 m DIV 40 Status SET UP 3 With the mouse pointer positioned inside the selection rectangle drag the rectangle to achieve the desired offset in this example vertically centered at the center of the screen File Edit View Scaling Options Help Mode Scroll Channels 0 1 2 3 S s F3 2000 i_i Compress F7 1 Storage used Ub36b
37. ALT 5 Six 8 windows 8 ALT 6 overlapping waveforms Seven 8 windows 8 ALT 7 Eight 16 windows 16 ALT 8 overlapping waveforms Nine 16 windows 16 ALT 9 Ten 32 windows 32 ALT 0 User Specified any non standard 32 ALT See the VARIABLE WAVEFORM ASSIGNMENTS section of this chapter for information pertaining to the assignment of any waveform channel to any window 48 WAVEFORM RECORDING WITH WINDAQ Tach DISPLAY MODE SELECTION FUNCTION Used to select the way information is displayed on your monitor either in a continuous smooth scroll mode or in a triggered sweep oscilloscope mode The display mode you choose for any given application is defined by many variables but perhaps the most important of these is choosing a mode you feel most comfortable viewing It is important to note that either display mode may be enabled at any time during data acquisition without affecting the information being stored to disk Display mode changes only affect the way you view waveforms on your computer s monitor ACTIVATING PROCEDURE To select a display mode oe Click the Scroll Mode button in the ToolBox OR OSC Click the Oscilloscope Mode button in the ToolBox DO Point to the Options menu and drag down to Scroll Mode or Oscilloscope Mode OR Double click on the Mode field in the status bar Y Choose Options Scroll Mode ALT O S or Options Oscilloscope Mode ALT O O Note that in either display mode the waveform dis
38. AWING A SELECTION RECTANGLE AND A GRAPHIC SELECTION RECTANGLE In WINDAQ Tach you can draw a graphic selection rectangle and just a plain selection rectangle A graphic selection rectangle is used to copy the graphics bounded by the graphic selection rectangle drawn with the mouse to the clipboard The selection rectangle is used with the mouse just to offset and or scale a waveform Both rectangles are drawn the same way only the graphic selection rectangle is created with the right mouse button while the selection rectangle is created with the left mouse button A graphic selection rectangle is drawn by positioning the mouse pointer anywhere in the waveform strip area and dragging with the right mouse button until the rectangle encloses the area you wish to copy to the clipboard When the mouse button is released the rectangle remains fixed in size You can now choose Copy from the Edit menu to copy the enclosed graphics to the clipboard A selection rectangle is drawn by positioning the mouse pointer anywhere in the waveform strip area and dragging with the left mouse button until the rectangle reaches the desired size When the mouse button is released the rectangle remains fixed in size The following examples illustrate how the selection rectangle can be used in typical offsetting and scaling operations 12 WAVEFORM RECORDING WITH WINDAQ Tach Offsetting a Specified Channel s Waveform Haje Sayal banheie O t i 3 Sa FJ
39. DAQ Tach configuration parameters such as update interval scroll limit skip factor buffer size beep on gap frame rate maximum sample rate event mark capacity open new file on full record next file on full and thermocouple type to better suit your computer hardware or otherwise influence operation Each preference item is described as follows ACTIVATING PROCEDURE Update Interval Allows you to specify the minimum time in milliseconds between screen updates By setting a minimum time interval between screen updates you prevent WINDAQ Tach from using too much CPU time at the expense of other tasks It should be noted that this preference item is simply a graphics adjuster that only affects how the display looks on your screen Data acquired to disk is independent of this function Valid update interval entries range from 0 to 32 767 The default interval is 0 At an interval of 0 no time between screen updates the display is optimized it will update as fast as your display controller hardware will allow However at this setting WINDAQ Tach burdens the CPU with constant screen update requests The CPU spends most of its time providing this optimized display thus leaving little time to process other tasks At an interval of 32 767 approximately 33 seconds between screen updates the display is at the opposite end of the performance spectrum updating very slowly Because of these infrequent screen update requests the CPU has a lot
40. DAQ Tach mouse actions require only the left mouse button For example carrying out a menu command or working in a dialog box requires only the left mouse button However the right mouse button is not totally neglected Among other things the right mouse button is used for copying waveform data to the clipboard waveform scaling selecting a waveform channel centering the cursor on the screen and moving the horizontal crosshair on a spectrum plot when in the WINDAQ Waveform Browser FFT mode Since the majority of mouse procedures are done with the left mouse button we will not specify which mouse button to click drag or double click with in the procedures unless it is the right mouse button When the right mouse button is required it will be specified as such For example Double click the right mouse button anywhere in the bottom annotation line to move the cursor to the lowest displayed waveform valley When not specified the left mouse button is assumed for the procedure e Point means to position the mouse pointer until the tip of the pointer rests on what you want to point to on the screen For example Point to the View menu e Click means to press and immediately release the mouse button without moving the mouse For example To display the menu that contains the command you want click the menu name in the menu bar e Double click means to click the mouse button twice in rapid succession For example
41. E COMMENT ALT F D Save current screen design as default condition 41 WAVEFORM RECORDING WITH WINDAQ Tach DIGITAL INPUT CHANNEL FEATURES FUNCTION Two separate functions on the Scaling menu allow you to manipulate and store digital input channel information along with all of the analog data The Analog Plot function toggles the digital input channel display between a bipolar analog plot and a digital individual bit plot The Digital Plot function displays the digital input channel as a digital subchannel featuring each individual bit A digital input channel is going to display either a high signal or a low signal nothing more or nothing less These two functions offer two different ways of displaying the same high or low digital signal information The Analog Plot function allows you to toggle the display of these high or low signals between an analog plot of a digital channel with a display similar to the output of a D A converter and a digital plot that shows the state per bit The Digital Plot function allows you to display the high or low state per bit O to 7 with a display option for normally open or normally closed conditions Each feature is described as follows ACTIVATING PROCEDURE Both of these functions are normally dimmed on the Scaling menu until a channel is specified as a digital input refer to the Configure ADC Channels Function for details on how to make a channel a digital input When the selected channel is a digit
42. I 720 USB and DI 730 USB data acquisition hardware from DATAQ instruments This hardware provides the best balance in terms of channel count and flexibility for the intended application but other hardware support may be added in the future Your WINDAQ Tach data acquisition system allows three operating modes during acquisition These are in logical order of occurrence Setup Record and Standby Each operating mode shares many features with the other three but there are some features accessible only from one given mode The three modes are discussed in detail as follows The SET UP operating mode is active when WINDAQ Tach is first started SET UP is used to configure data acquisition parameters such as the number of acquired channels their type differential or single ended channel programmable gain and channel programmable offset In addition this mode is used to adjust the real time display for a visually pleasing presentation Virtually all other data acquisition functions and adjustments are available from the SET UP operating mode including control of the real time display screen s scaling and offset functions In this mode only the real time display is active data is not yet being streamed to disk When in this mode the Status area of the bottom annotation line displays SET UP The RECORD operating mode is active when a file has been opened and the Record command has been chosen RECORD is used to stream waveform information to disk
43. IAL CONSIDERATIONS The value of engineering units may range from 1 0 E 32 to 1 0 E 32 EXAMPLE Accelerator key Version KEYSTROKE COMMENTS 1 Select the window to receive engineering unit data F11 Prepare to enter high calibrator value 500 Enter high calibrator value F9 Prepare to enter low calibrator value 500 Enter low calibrator value o F degrees Fahrenheit Enter engineering unit tag ENTER Complete the high low calibration entries 101 WAVEFORM RECORDING WITH WINDAQ Tach WAVEFORM COMPRESSION FUNCTION FUNCTION Allows you to vary the number of data points that are used to display the real time waveform on your computers screen Increasing the compression factor causes the display to plot less often which results in a slower real time display the waveform is being displayed at a fraction of the selected sample rate It should be noted that this function is simply a graphics adjuster that only affects how the display looks on your screen Data acquired to disk is independent of this function and is always acquired continuous gap free at a compression factor of 1 meaning no compression applied Plotting or displaying the waveform data on your computer s monitor is the most time consuming task WINDAQ Tach is burdened with The plotted waveform you see on your monitor is a compilation of many vertical line segments drawn adjacent to each other The length and position of each vertical line segment drawn on the
44. Pixels moves the specified waveform down 10 pixels in the strip Moving the specified waveform up in the stri DO Point to the Scaling menu and drag down to Waveform Up 1 Pixel or Waveform Up 10 Pixels Waveform Up 1 Pixel moves the specified waveform up a single pixel in the strip and Waveform Up 10 Pixels moves the specified waveform up 10 pixels in the strip OR 1 Drag in the waveform strip area to draw a selection rectangle around a portion of the waveform The size of the selection rectangle does not matter it is merely used to represent the current horizontal position of the waveform on the screen 2 With the mouse pointer positioned inside the selection rectangle drag the selection rectangle up to move the specified waveform up in the strip to the desired position within the limits defined by the A D converter 106 WAVEFORM RECORDING WITH WINDAQ Tach WY Choose Scaling Waveform Up 1 Pixel or Scaling Waveform Up 10 Pixels ALT C P or ALT C U respectively Waveform Up 1 Pixel moves the specified waveform up a single pixel in the strip and Waveform Up 10 Pixels moves the specified waveform up 10 pixels in the strip SPECIAL CONSIDERATIONS As a scaling or offset operation is performed on any given channel the channel s annotated full and base line values will automatically adjust to reflect the operation Scaling and offsetting data does not in any way affect the information stored to disk These operations
45. SI in the Engr Units text box b For the case where the transducer output is unknown we would also enter 0 in the Low Cal Value text box ignore the Input Level text box WINDAQ Tach has established the input voltage level for you and enter PST in the Engr Units text box Press the TAB key to position the insertion point in the various text boxes Type up to a four character optional engineering unit tag 1 e PSI f s rpm etc 2 Complete the low calibration entry as follows Click OK Press the TAB key until a bold border surrounds the OK command button indicating selection and press ENTER The Low Calibration dialog box disappears and if no high calibration has been done yet an offset is applied to the waveform to achieve the entered value But you are only half done it takes two points to define a line and so the high calibration must be done 1 Select High Calibration as follows Point to the Edit menu and drag down to High Calibration Choose Edit High Calibration ALT E H 99 WAVEFORM RECORDING WITH WINDAQ Tach When selected the High Calibration dialog box is displayed on the screen High Calibration x Input Level sd Not High Cal Value O cancel Again the insertion point appears behind the value in the High Cal Value text box This insertion point indicates the active area of the dialog box the next action you perform will occur in this area This is where you enter
46. Tach OPEN REFERENCE FILE FUNCTION FUNCTION Allows you to specify an existing data acquisition file as a set up for a new data acquisition file All data acquisition parameters such as number of channels channel type scaling constants engineering units display format compression display mode gain etc are ported over from the existing file to become the default conditions of the new data file This function allows instantaneous setup thus making it easy to run similar but separate data acquisition sessions This function sets parameters only for the new data file being created The Default Conditions function is similar but it sets default parameters for all future data files ACTIVATING PROCEDURE Fef Click the Open Reference File button in the ToolBox Point to the File menu and drag down to Open Reference File Choose File Open Reference File ALT F F SPECIAL CONSIDERATIONS The file specified as the reference file must be one created by WINDAQ Tach and must already exist This function is enabled only when in the SET UP operating mode Status field in bottom annotation line indicates SET UP EXAMPLE None No accelerator key version available for this function 59 WAVEFORM RECORDING WITH WINDAQ Tach PALETTE SELECTION FUNCTION Allows the selection of one of 16 pre defined display palettes Additionally a user palette option allows you to redefine the color scheme of the displays by selecting di
47. Tach automatically and transparently allocates the correct amount of buffer space when you input a sample rate However if you have increased the buffer size via Edit Preferences there is a chance that the sample rate you enter is too high for the amount of buffer space you have allocated If this is the case the S s F3 value in the status bar will be displayed in reverse video as follows 76 WAVEFORM RECORDING WITH WINDAQ Tach ax DI 220 Acquisition File Edit Miew Sealing Options Help Mode Seroall Channels U 1 ae LEGT Com ress FP Reverse video ee ee ee This serves as a warning that you might not be able to reliably store data to disk with the current combination of sample rate and buffer size Refer to Appendix A Different Ways of Allocating Memory for complete details if a reverse video condition is achieved If none of the steps in Appendix A helps you have two options lower the sample rate or increase the buffer size When the desired sample throughput rate is entered close the dialog box by DO Clicking the OK command button Pressing the ENTER key SPECIAL CONSIDERATIONS The sample rate shown is a throughput rate The sample rate per channel obtained by dividing the selected sample throughput rate by the number of channels enabled is displayed in the bottom annotation line as S s CHAN Although there are thousands of different sample rates that may be configured some discrete rates are not a
48. ToolBox DO Point to the Edit menu and drag down to Sample Rate OR Double click on the S s F3 field in the status bar Choose Edit Sample Rate ALT E R This displays the sample rate dialog box as follows sample Rate Input Buffer Size in KiloBytes 0 Disk Buffer Size in KiloBytes 20 sample Rate 1000 Ea 74 WAVEFORM RECORDING WITH WINDAQ Tach The minimum sample rate you can specify is equal to the number entered in the Maximum Sample Rate dialog box Edit Preferences Maximum Sample Rate divided by 32 767 In order to enter a sample rate of less than 1 in the Sample Rate text box effectively sampling about once per minute you must also lower the maximum burst rate This is done as follows D 1 Point to the Edit menu drag down to Preferences and release the left mouse button 2 Inthe Edit Preferences submenu click Maximum Sample Rate o Choose Edit Preferences Maximum Sample Rate ALT E P M This displays the maximum sample rate dialog box Maximum Sample Rate MLI OK Cancel Enter in the text box the minimum value for maximum burst rate Just as before minimum and maximum burst rate values vary by instrument but a value that will work for most all instruments is 500 you can find the absolute lowest maximum burst rate by entering an obviously low number in the text box such as 10 The software will reject 10 and respond with a dialog box that states the minimum and ma
49. WAVEFORM RECORDING WITH WINDAQ Tach Table of Contents Waveform Recordin with WANDAO Tac Ii csssvasssscissssensaccasentoonsesasaessvindonseeiaisen AA AANER a Required Hardware Connec ONS sinni a EN N naedsucnaaenrashdeuns ca iageasSelwoennes 5 REFERENCE INFORMATION soera a a a a N E S 7 CONVENTIONS USED IN THE DOCUMENTATION eesssssssssssseeereeesesessssssssseeeerresssesssssssessseeeeeeeeseesssssesee 7 Mouse Convention Sere e aE A TET ANE TAAT EAE AT TEAT 7 Keyboard OM V CTU ONS ssa tl these ds vara aa A ss urn nara ou gam aaaes carne Sabon ue vatds Maumneda gues auugnoes 8 STARTING THE WinDagq Tach WAVEFORM ACQUISITION PROGRAM cccsssscccceceeeeeeeeeseesessesnnaeeeees 8 THE WINDAQ Tach WAVEFORM ACQUISITION WINDOW ccccccsesssnnceeeeeeeeeeeeeeeeeeeesnneeeeeeeeeeeeesseneeeeegs 9 DRAWING A SELECTION RECTANGLE AND A GRAPHIC SELECTION RECTANGLE eee 12 Olisetins a Specified Channel s WavelOriiicsccrecssid cused lexuara tadchanct hue ni aceon Ea 13 Scaling a Specified Channel s Waveform aisniciiedn i eh ces cecdi tia caed Seatac a a 15 A TYPICAL DATA ACQUISITION SCREEN USING WinDag Tach ce cccccccccceeeeeeeseeesennnneeeeeeeeeeeeneeeeeens 17 WanDdg Tach Pulle Down Me NUS r E EE a AAE 18 WINDAG Fach OMIMA ND HIERARCHY uresni E GN 19 WINDAO Tach OPERATING MODES pono ticnetocrniin aieo a e E a aa aaa aaa ai 21 GENERA ca ase ahd eben slr i wr cea el dated alas race wa i dare hans sa aa aio daveanslle E al
50. a ee pe ae a a Variable waveform Non overlapped screen format assignment indicator D 720 Acquisition x File Ect iew Scaling Options Help Mode Oseill Channels O 1 2 3 Compress I Overlapped screen format Variable waveform assignment indicator The variable waveform assignment indicator allows any enabled channel to be assigned to a specified display window The highlighted box surrounding the X Y annotation indicates that the window is selected meaning the waveform contained in the strip can be scaled offset or otherwise adjusted Note that the waveform can only be scaled or adjusted when the window is selected Numeric value of waveform at real time point This field appears when Data Display is enabled from the Options menu When Current Data is enabled also from the Options menu in the oscilloscope display mode this field displays the waveform value at the cursor position When Current Data is enabled in the scroll display mode this field displays the waveform value at the real time point rightmost edge of window When Current Data is disabled this field displays the baseline value of the waveform window Full scale values for the waveform strip These values indicate the full scale values of the waveform window If desired these values may be specified and the waveform will be automatically scaled to fit the new values This is useful for displaying the waveform strip in whole numbers e g O 200 mmHg instead of 1
51. ability to close a full file and display the dialog box required to open another new file For example say you are acquiring data and the file becomes full much sooner than you anticipated yet you still need more data If this preference is disabled you would have to close this full file and then select the Open command from the File menu to name and open a new file thus continuing the acquisition session If this preference is enabled you bypass the need to close the full file and select File Open The File Open dialog box is automatically displayed for you conveniently allowing you to enter a new file name If this preference is enabled and if the old or full filename excluding file extension consists of just alpha characters e g WEASEL WDQ the File Name text box of the Open dialog box is highlighted enabling you to immediately enter a new file name If the old filename excluding extension ended in numeric digits e g WEASEL1 WDQ the numeric portion is automatically incremented e g WEASEL2 WDQ and highlighted in the File Name text box of the Open dialog box suggesting the default new name This feature allows you to acquire data to a series of sequentially named files If the numeric suffix of the old name is all nines e g WEAS9999 WDQ no specific next name is suggested To enable this preference if disabled or disable it if enabled 1 Point to the Edit menu drag down to Preferences and release the left mouse button
52. ah conde 21 WINDAOQ Tach GENERAL ANBORMATION perospunnanie reniant aE E aE RS 23 INSTALEA TION rth darters sh Sec cta eat gearsat da cri a Ste tse annus eb analy dne bonanhcdd eae taadona aurea apuaes da cnneatea eau steies 23 DIGIT MIN Tn a eet eadueaciade anette Roe taace oamancuaac teat ane tate umasnanen tas maaan oemeahy cottatalaaaatsd 23 COMMAND IE ERIN Bacardi tert seen a dares oa eins dal aa acta a in alta a a 25 ACOUIRE DATA TO DISK FPUNCGCTHON desiere eera E NAE AE hsatoueaceasaucalantontes 26 BEEF ON FILE FULE FUNCTION cerei uooannia Sessile snaael dosdiasude sbonande sun dwaen seed sone tu hauaamaasenandes 36 CEO COIN soso ca certantascatcn psec ast age cautanaaateestaaeseeved see aosmea ta saato Osh a n AonteiaiGacans 37 CONFIGURE ADC CHANNELS FUNCTION tepara he ton dansan shia eicen deta ennai das kink teen a sotan de 38 Enable sine le ended C Nannies i ccsesescdsacschneanincacesesees EE AAA 39 COPY FUNCTION ce ares ed acts a e anise anon an ea ta hase ettsga nada cae tides A E Suis 40 DEFA ULTCONDITIONS FUNCTION canse a E a ee steadeteatastnees eet aad 41 DIGITALINPUT CHANNEL FEATURES motnbdieeoin enua e aa er 42 DISPLAY FORMA TSELECTION onire An panan E E EE A E AE 44 DISPLAY MODE SELECTION reten a Uocranna Seay datas nated desu eb amauad Gumesidatinn ane dsnoussaed emuanatasen andes 49 EVENT MARKER FUNCTION wacaicoialicntoncuicstinccatagetaceaaosadien GhaisaRoraiatahstacaauesnacen Go stend a E Soitaldaacen 52 FAST SCROLL PUNC ION curent
53. ake less processor time which results in faster screen updates However if the scrolling speed is slow scrolling by 16 pixels detracts from the smoothness of the scroll and delays the presentation of new data by 16 samples per channel ACTIVATING PROCEDURE Point to the Options menu and drag down to Fast Scroll Choose Options Fast Scroll ALT O F When the fast scroll option is enabled a checkmark V will be displayed on the Options menu immediately preceding the Fast Scroll command SPECIAL CONSIDERATIONS None EXAMPLE Accelerator key version No accelerator keys available for this function 55 WAVEFORM RECORDING WITH WINDAQ Tach HELP FUNCTION HELP is a complete online reference tool that you can use at any time to display a brief summary of the contents of this chapter When you finish reading the HELP information acquisition returns you to the WINDAQ Tach waveform display screen with everything exactly as you left it HELP information is displayed in its own window you can move and size the HELP window just as you would any other window ACTIVATING PROCEDURE How to navigate within Help is thoroughly documented onscreen therefore only cursory information will be covered here WINDAQ Tach Help provides e Information on WINDAQ Tach commands concepts basic tasks and parts of the screen e Help on a highlighted command e The ability to jump to a related topic or definition of a term You use the var
54. al input both of these functions are selectable Analog Plot This function has two purposes It displays a bipolar analog plot of a digital input channel and it also serves as a toggle switch between an analog plot and a digital plot of the selected digital input channel The analog plot displays the digital input channel in a way similar to the output of a D A converter When this function is enabled the selected digital input channel information is displayed as an analog plot and a checkmark is displayed on the Scaling menu immediately preceding the Analog Plot command When this function is disabled the selected digital input channel information is displayed as a digital plot and the check mark is removed from the Scaling menu in front of the Analog Plot command To enable an analog plot of a digital input channel D Point to the Scaling menu and drag down to Analog Plot Choose Scaling Analog Plot ALT C N Digital Plot This function displays the digital input channel as a digital subchannel featuring each individual bit The default display shows a vertical line for each data point that contains at least one high signal If the signal you wish to monitor is usually high the vertical line can be inverted so it is displayed for each data point that contains at least one low signal When this function is enabled the selected digital input channel is displayed as a digital plot with each individual bit digital inputs 0 thr
55. ayed at all times in all operating modes SPECIAL CONSIDERATIONS None EXAMPLE None 84 WAVEFORM RECORDING WITH WINDAQ Tach TOOLBOX FUNCTION FUNCTION When enabled a floating toolbox of buttons is displayed on your screen The toolbox buttons provide quick access to commonly used commands ACTIVATING PROCEDURE When you first start WINDAQ Tach the toolbox is hidden disabled To display the toolbox Point to the View menu and drag down to ToolBox Choose View ToolBox ALT V T This displays the ToolBox fe WinDaq ToolBox Each button on the ToolBox provides quick access a shortcut to a commonly used WINDAQ Tach function as follows Open Reference File Open Close File Start Stop Recording Enable Channels Channel Setup Calibration Sample Rate Waveform Compression Commented Event Marker D gt A Rett otte Oscilloscope Mode Scroll Mode Shift Waveform Down Shift Waveform Up Shrink Waveform 2x Expand Waveform 2x Change Palette Show Hide Grid Hide Pep 85 WAVEFORM RECORDING WITH WINDAQ Tach Open Reference File Allows you to use the parameters in an existing data file as a set up for a new data acquisition file When this button is activated the Open Reference File dialog box appears prompting you for the set up file name and path This button is the same as choosing Open Reference File from the File menu Refer to the Open Reference File Function for complete deta
56. ble the display of screen updates in frames sec When enabled the number of screen updates per second how many times per second the display is redrawn or updated is displayed in the right end of the status bar To enable the frame rate if disabled or disable it if enabled KD 1 Point to the Edit menu drag down to Preferences and release the left mouse button 2 Inthe Edit Preferences submenu click Frame Rate o Choose Edit Preferences Frame Rate ALT E P F When the frame rate option is enabled a checkmark V is displayed on the Edit Preferences submenu immediately preceding the Frame Rate command Maximum Sample Rate nonfunctional when used with serial port instrumentation Allows you to set the maximum burst rate which ultimately determines the sample rate On some computers a burst rate near 830KHz can result in channel swapping i e the data from one channel is displayed on a different channel on the screen and in the data file when DOS programs are run simultaneously with WINDAQ Tach or can even halt the system with a memory parity error To specify maximum sample rate 1 Point to the Edit menu drag down to Preferences and release the left mouse button 2 Inthe Edit Preferences submenu click Maximum Sample Rate Y Choose Edit Preferences Maximum Sample Rate ALT E P M This displays the maximum sample rate dialog box Maximum Sample Rate SUN OK Cancel Enter in the text box the des
57. chievable This limitation is due to the inability to divide the master clock in a manner that results in a quotient that is an even number For example this is the reason why you get a sample rate of 2999 63 when you entered 3000 EXAMPLE Accelerator key version KEYSTROKE COMMENTS F3 Displays the Sample Rate dialog box Enter the desired sample rate 71 WAVEFORM RECORDING WITH WINDAQ Tach SCREEN ANNOTATION CONTROL FUNCTION FUNCTION Allows you to configure the on screen waveform annotation many different ways Options such as current data data display limit display and user annotation can be enabled or disabled in any combination to customize the waveform display Each annotation option is described as follows ACTIVATING PROCEDURE Current Data This option allows you to enable disable the display of the current waveform data value in the left or right annotation margin The Data Display option must be enabled to display current waveform data When this option is enabled in the oscilloscope mode the current waveform data value at the cursor position is displayed in the annotation margin The cursor or erase bar does not have to be enabled When enabled in the scroll mode the current waveform data value at the real time point far right screen edge is displayed in the annotation margin When this option is disabled in either mode the base line value is displayed in the left right annotation margin if Data Display
58. creen display purposes a 1 1 relationship It should be noted that this preference item is simply a graphics adjuster that only affects how the display looks and performs on your screen Data acquired to disk is independent of this function Real time display performance degrades when attempting to plot too many data points in a given period of time Specifying a skip factor improves real time display performance by lessening the plotting workload With a skip factor you improve display performance by instructing WINDAQ Tach to plot every nth data point and ignore the rest of the incoming data However since the rest of the data is ignored the result is a potentially inaccurate screen representation of the acquired data Therefore the skip factor should be considered a last resort for improving display performance if screen accuracy of the waveform data is desired Valid entries range from 1 to 100 At a factor of 1 no sample skipping the screen display is the most accurate detailed representation of the acquired data However at this setting the CPU is burdened with constant plotting operations At a factor of 100 plot every 100th data point on the screen and ignore the rest CPU operations for the real time display are minimal the workload is lightened but the displayed waveform is at best only a compromised representation of the acquired data To specify a skip factor 1 Point to the Edit menu drag down to Preferences a
59. d and the enclosed graphics can be copied to the clipboard as follows DO Point to the Edit menu and drag down to Copy Choose Edit Copy ALT E C SPECIAL CONSIDERATIONS The graphic is copied to the clipboard in bitmap and device independent bitmap DIB formats EXAMPLE Assumes a graphic selection rectangle is drawn KEYSTROKE COMMENT CTRL C Copies current contents of graphic selection rectangle to the clipboard 40 WAVEFORM RECORDING WITH WINDAQ Tach DEFAULT CONDITIONS FUNCTION FUNCTION Allows all current WINDAQ Tach parameters to become the default condition so all subsequent data recording sessions will have the current display format sample rate channels enabled etc This function sets default parameters for all future data files The Open Reference File function is similar but it only sets default parameters for the one new data file being created ACTIVATING PROCEDURE When you have set up WINDAQ Tach exactly the way you like you can make this configuration the default so every time you start WINDAQ Tach it always appears this way To make the current screen design the default condition D Point to the File menu and drag down to Save Default Setup Choose File Save Default Setup ALT F D SPECIAL CONSIDERATIONS Virtually every WINDAQ Tach data acquisition parameter is saved to determine the default condition Enabled display format sample rate compression channels enabled etc EXAMPLE KEYSTROK
60. d displays the sample rate dialog box the same as choosing Sample Rate from the Edit menu or clicking the Sample Rate button in the ToolBox Double clicking on the Channels field displays the channels selection block cursor just like selecting Edit Channels Double clicking on the Compress F7 field displays the compression dialog box similar to selecting Edit Compression Left Right Margin 4 used Framess 16 53 The left and or right annotation margin has three purposes it can be used for channel selection it can be used with the mouse to scale the displayed waveform and it displays the numerical values of the waveform When more than one waveform is displayed on the screen clicking the left mouse button in the unselected channel s annotation margin selects that channel Clicking the left mouse button in the annotation margin of a selected channel doubles the vertical size of the waveform Conversely clicking the right mouse button in the annotation margin of a selected channel reduces the vertical size of the waveform by one half Clicking the right mouse button in the annotation margin of an unselected channel starts a graphic selection rectangle which is used by the Edit Copy command A selection rectangle can also be used with the annotation margins to scale the waveform For example if you wanted to examine a small section of waveform in greater detail it is possible to fill the entire channel with the
61. d on the Edit Preferences submenu immediately preceding the Record Next File on Full command Thermocouple Not applicable to WINDAQ Tach software SPECIAL CONSIDERATIONS None EXAMPLE Accelerator key version No accelerator keystrokes for Preferences items 70 WAVEFORM RECORDING WITH WINDAQ Tach QUIT FUNCTION When issued the Exit command quits WINDAQ Tach ACTIVATING PROCEDURE Point to the File menu and drag down to Exit Y Choose File Exit ALT F X When in the SET UP operating mode and the Exit command is chosen the following dialog box is displayed You are required to select one of the options prior to exiting Exiting DIZ00AC Do you want to exit 7 Cancel OK Command Button Activating the OK button forces the acquisition program to exit to the Program Manager window without saving anything 1 e calibration or set up parameters If calibration or set up parameters were previously provided and saved by using the SAVE DEFAULT SETUP command they will be unaffected by this command Cancel command button Activating the Cancel button returns you to the acquisition display cancels your exit request SPECIAL CONSIDERATIONS When in either the RECORD or STBY operating mode and an exit is requested the prompt in the exit dialog box indicates that the data file will first be closed if the OK button is selected Exiting DIZ00AC Do you want to close file and exit 7 7 Cancel In t
62. de the waveform is not displayed until a trigger condition is detected The waveform will be displayed for a single sweep on your monitor only when a trigger 1 e that point on the waveform in the selected channel that corresponds to the level and slope specified is detected Although it looks similar to the Acquisition Triggering dialog box this dialog box only sets triggering conditions for the waveform display not for acquisition to disk The triggered sweep display best used with repetitive waveform signals allows you to set a level and a slope defining the starting point or trigger for the waveform display The waveform will be sweep displayed on your screen only when a trigger 1 e that point on the waveform that corresponds to the level and slope you selected is detected This produces a stable display easily measured or compared with other waveforms since it starts at the same point on the screen with every sweep This single sweep display will remain on your monitor until the next trigger is detected The free running display allows the waveform signal to free run without any triggering conditions Without triggering conditions to define a starting point the free running display updates continuously Slope option buttons The slope option buttons allow you to select the slope positive or negative at which the waveform display will trigger Selecting the option button triggers the display to start at the trigger level
63. dge limits in the left right annotation margin If Data Display is disabled engineering units toggle on and off along with the limits To enable the upper and lower chart edge limit display if disabled or disable them if enabled DO Point to the Options menu and drag down to Limit Display Y Choose Options Limit Display ALT O L When the limit display option is enabled the annotation margin will have the following appearance and a check mark V will be displayed on the Options menu immediately preceding the Limit Display command File Edit View Scaling Options Help Mode Scroll Channels 0 1 2 3 F3 E Limit display enabled User Annotation This option allows you to enable disable toggle the display of user annotation entered from the Edit menu User Annotation command in the waveform strip To enable user annotation if disabled or disable it if enabled DO Point to the Options menu and drag down to User Annotation Choose Options User Annotation ALT O U When user annotation is enabled the waveform strip will display the specified channel s annotation entered with Edit User Annotation and a checkmark V will be displayed on the Options menu immediately preceding the User Annotation command File Edit View Scaling Options Help 0 1 2 3 SSS User annotation enabled SPECIAL CONSIDERATIONS Screen annotation options can be enabled in virtually any combination to provide the desired result How
64. during the data acquisition process using simple keystrokes 5 The following illustrations all depict full screen displays that is WINDAQ Tach is taking up the whole screen It is entirely possible and most probable that you will have other application windows open simultaneously with WINDAQ Tach In order to do that you must make the individual windows small enough for more than one to fit on your monitor Therefore the screens depicted here will not necessarily be what you see when you are running other applications concurrently 44 Display Format 1 DI 200 Acquisition la Eile Edit Yiew Scaling Options Help F3 1000 z Channels 0 Waveform Window 1 Number of displayed channels 1 Number of displayed windows 1 Display Format 3 D200 Acquisition File Edit View Scaling Options Help Mode Scroll Channels O0 F3 1000 Fii Waveform Windows 1 amp 2 Number of displayed channels 2 Number of displayed windows 2 Display Format 5 DI 200 Acquisition me File Edit View Scaling Options Help Mode Scroll Channels 0 F3 10000 Waveform Windows 1 2 3 amp 4 Number of displayed channels 4 Number of displayed windows 4 45 WAVEFORM RECORDING WITH WINDAQ Tach Display Format 2 DI 200 Acquisition Channels Eile Edit View Scaling Options Help Hode Scroll A F3 1000 Waveform Windows 1 amp 2 overlapped Number of displayed channels 2 Number of dis
65. e currently setting up SPECIAL CONSIDERATIONS As the gain factor for a channel is sequenced upward and downward through gain ranges full scale annotation adjusts to reflect the application of the various gain factors A channel s gain factor cannot be adjusted following the initiation of data storage to disk Only the SET UP operating mode allows gain factor adjustments EXAMPLE Accelerator key version KEYSTROKE COMMENT 2 Enable waveform window 2 F10 Displays the Channel X Settings dialog box 4 Selects a gain factor of four for the waveform contained in window 2 35 WAVEFORM RECORDING WITH WINDAQ Tach BEEP ON FILE FULL FUNCTION FUNCTION When enabled this option sounds an audible beep when the target data acquisition file is full ACTIVATING PROCEDURE To enable the beep on file full function D Point to the Options menu and drag down to Beep on File Full Choose Options Beep on File Full ALT O B SPECIAL CONSIDERATIONS Before a file can be opened you must specify a file size or accept the default in the File Size dialog box When enough data has been recorded to fill the allocated file space an audible beep sounds when this function is enabled to warn you that acquisition has stopped and WINDAQ Tach is in the STBY operating mode EXAMPLE None No accelerator keys for this function 36 WAVEFORM RECORDING WITH WINDAQ Tach CLOSE FUNCTION FUNCTION Allows you to close the data file you ar
66. e currently working with Closing a data file removes the file from your screen but does not quit WINDAQ Tach ACTIVATING PROCEDURE A new data file must first be opened and data must be recorded to it before the Close command becomes selectable undimmed However the Close command is immediately selectable on an existing data file that you are appending to Once Close becomes selectable you can close a currently open data file as follows DO Point to the File menu and drag down to Close Y Choose File Close ALT F C SPECIAL CONSIDERATIONS None EXAMPLE None No accelerator keys for this function 37 WAVEFORM RECORDING WITH WINDAQ Tach CONFIGURE ADC CHANNELS FUNCTION FUNCTION Used to specify the ADC channels to be acquired and whether these channels are configured for single ended differential or digital operation ACTIVATING PROCEDURE The following procedure is used to specify the analog channels to be acquired and whether these channels are configured for single ended differential or digital operation To enable or configure channels for acquisition you must be in the SET UP operating mode Channels cannot be added to deleted from or configured in the data acquisition file once the RECORD mode has been entered To activate analog channel configuration E E Click the Enable Channels button in the ToolBox DO Point to the Edit menu and drag down to Channels OR Double click on the Channels field in t
67. e n a e a a diane 55 HELP ee A A E E E N E A E E E E E 56 INVERT FUNCTION edea a A a EAA 57 LOCA TION aoao a E a E cite ecesen wer tty Sen ncet mare Cry eee Na er en 58 OPEN REFERENCE FILEFUNCTON cess than tases a a ies stein allele nde 59 PALETTE SELECTION aop sesso anice piesa E E anus ees E E E 60 PREFERENCES Bich seco ees E A 64 OI EEA A E EE AET EE TE E IET AEA AT EAEE TE AEN TEE E SEE IEAI EE TEE ATTE 71 RANGE OF CHANNELS FEATURE coren e a a a a a T2 SAMPLE RATE SELECHON scsicoscsnesusacaanancasaausodaagassueateatinansaabiseavaauiocastaiaeessanhandtenanare sa eaasommebaeianasaauoaaniesbaceanantintet 74 SCREEN ANNOTATION CONTROL FUNCTHON ciiirt ea E E 78 SCREEN GRID PATTERN CONTROL FUNCTION essssesssesseereeesssssssssssssseeeressssssssssseeeereeeseeessssssessseeereeeeeessss 81 SHOW DYNAMIC RANGE sae ahah waa aca end alte ae os aed ena asa ata A 82 PING RO Ute sis I ase yscanse cans seseann cian ssa anteagsencbinAat ET a 83 DISTANCE PER DIVISION FUNCTION sicasic sibcecs acnddeeasds uscmsiid E hdeianann dane san smmaees seasenahdes 84 TOOLBOX FUNCHON eraran onna aa a Gneeaceneo EA 85 UNDO FUNCTION rrene a a a a T S 89 USER CHANNEL ANNO PA TION FUNCTION earsisreseniea ieaoo Tran ne aT aa KAEA 90 VARIABLE WAVEFORM ASSIGNMENTS creonau e E a 91 WAVEFORM CALIBRATION FIXED METHOD ssssoosssesessessssssssssssssrrreeessssssssssssserreeeeeessssssssssssrerrreeeeesess 93 WAVEFORM CALIBRATION HIGH LOW METHOD 1 ccccccccssssssnneeeeeeeeeeeee
68. e read from the manufacturers specifications or verified through use they can be used as calibration values There is no need to determine or full scale or baseline values with this method any known transducer output relationship can be used With this method you can even calibrate the data without knowing the transducer output relationship Simply let WINDAQ Tach establish these output voltage values for you For example suppose you were acquiring pressure data and you had no idea what kind of output voltages to expect from the transducer you re using You could vent the pressure apparatus to quiesence or atmospheric pressure and observe what voltage the transducer is outputting at quiesence from the Input Level text box in the Low Calibration dialog box select Low Calibration from the Edit menu In this same dialog box enter what you would like this quiesent state to be such as 0 in the Low Cal Value text box and enter PSI in the Engr Units text box Now activate the OK command button to close the dialog box and increase the pressure until the manometer reads a convenient value say 100 PSI In a similar manner observe what voltage the transducer is outputting at this 100 PSI level from the Input Level text box in the High Calibration dialog box select High Calibration from the Edit menu Enter 100 in the High Cal Value text box enter PSI in the Engr Units text box activate the OK command button and you
69. eessesesesnnnaeeeeeeeeeeeeeees 98 WAVEFORM COMPRESSION FUNCTION ccistsssescensiecsannaspacsuesssnceasnaaanas tabaaunne acanissanhsadnaaatandaasauonlasaansensaatuadans 102 WAVEFORM RECORDING WITH WINDAQ Tach WAVEFORM DISPLAY SCALING AND OFFSET WAVEFORM RECORDING WITH WINDAQ Tach Waveform Recording with WINDAQ Tach GENERAL WINDAQ Tach is a special version of WinDaq Pro software that allows the X axis of WinDaq data acquisition software to be incremented based on distance as opposed to time WinDaq Pro is a Windows based data acquisition software package that gives any of our hardware products simultaneous real time display and data storage to disk capability At this time WinDaq Tach operates only with model DI 720 USB and DI 730 USB data acquisition hardware from DATAQ Instruments This hardware provides the best balance in terms of channel count and flexibility but other hardware support may be added in the future To operate WINDAQ Tach you will need two TTL signals a direction signal and a speed or tachometer signal For the DI 720 the direction signal connects to the event input on the front of the instrument pin 25 of the secondary connector The tachometer signal connects to the start stop input pin 6 of the secondary connector Common for both signals should connect to pin 28 or pin 19 Operation with the DI 730 requires an adapter cable part 100679 When this cable is plugged into the back of the instrument the pinout
70. er whose frequency is directly proportional to speed By combining the information from these two sources along with acquired analog information any anomaly detected on an analog waveform and subsequently stored to disk may be correlated with a precise location during playback When using WINDAQ Tach distance based data acquisition the operator must specify an analog channel sample rate high enough so that the reciprocal of the rate per channel is less than the minimum width of the tachometer pulses and the minimum spacing between pulses For example while recording three channels at 10 000 s s the tachometer pulses applied to the tachometer digital input must be at least 300 us wide and 300 us apart to ensure detection In order to avoid having to write the tachometer handling code in assembly language it will be implemented in 32 bit code for Win95 98 or Windows 2000 The digital inputs are sampled each time an analog data value is converted for the first channel in the scan list The state of the direction input when the tachometer pulse happens to be sampled will determine whether it is treated as a forward or backward motion The set of channel data on which the pulse was first detected will be displayed on the screen and stored to the file is recording The time skew between readings will be the reciprocal of the A D converter burst rate which is a multiple of the total sample rate less than or equal to Edit Preferences Maximum Sample Rate bu
71. erages all of the data points in the burst sample and reports this average as the single value for storage and display This is the most universal method and should be left on in all cases unless you wish to report peak or valley values in which case you would select the Maximum or Minimum button respectively Last Point This method simply reports the last input data point in the burst sample for storage and display The rest of the data points in the burst sample are ignored Maximum This method reports the highest value data point in the burst sample for storage and display The rest of the data points in the burst sample are ignored Minimum This method reports the lowest value data point in the burst sample for storage and display The rest of the data points in the burst sample are ignored Input Types Linear The default input type available on all instruments Should be used with all linear inputs Nonlinear Input Types Not applicable to WINDAQ Tach software Thermocouple Input Types Not applicable to WINDAQ Tach software Next and Previous Command Buttons The Next and Previous command buttons allow you to step through the next or previous enabled channel in order setting up each channel for gain unipolar bipolar sample rate etc without closing this dialog box Note that when either the Next or Previous button is activated the channel number in the title bar of the dialog box changes to indicate the channel you ar
72. ession factor of 1 As the waveform compression factor is changed the time base field ms DIV or sec DIV displayed in the bottom annotation line is automatically adjusted to reflect the proper time scaling of displayed waveforms 103 WAVEFORM RECORDING WITH WINDAQ Tach KEYSTROKE EXAMPLES Assumes an initial compression of 1 uncompressed KEYSTROKE COMMENTS F7 Display the compression dialog box 2 Specify a compression factor of 2 ENTER Apply the specified compression factor to the display PGUP Multiply the current compression factor by 2 PGDN Divide the current compression factor by 2 104 WAVEFORM RECORDING WITH WINDAQ Tach WAVEFORM DISPLAY SCALING AND OFFSET FUNCTION Used to dynamically scale or offset a specified channel s waveform on the real time display ACTIVATING PROCEDURE A channel must first be selected for scale and offset operations When selected the X Y annotation in the right or left annotation margin will be highlighted indicating window X is enabled for scale and offset adjustments Expanding the Specified Waveform NI Click the Expand Waveform 2x button in the toolbox D Point to the Scaling menu and drag down to Grow 2X This expands the specified waveform two times its original size in the amplitude direction OR Point to the right or left annotation margin and click the left mouse button This also expands the specified waveform two times its original size in the amplitude directi
73. ever in some instances one option will override another For example if Data Display is disabled it is not possible to enable Current Data Similarly if Limit Display is disabled it is not possible to enable Current Data 79 WAVEFORM RECORDING WITH WINDAQ Tach EXAMPLE Accelerator key version assumes an initial condition of no annotation displayed KEYSTROKE COMMENT ALT L Enable limit display F2 Enable data display ALT F2 Enable current data 80 WAVEFORM RECORDING WITH WINDAQ Tach SCREEN GRID PATTERN CONTROL FUNCTION FUNCTION Used to enable or disable the real time waveform display grid pattern ACTIVATING PROCEDURE Ed Click the Show Hide Grid button in the ToolBox This enables the grid if it was disabled or disables the grid if it was enabled DO Point to the Options menu and drag down to Grids This enables the grid if it was disabled or disables the grid if it was enabled Y Choose Options Grids ALT O G This also enables the grid if disabled or disables it if enabled When the grid pattern is enabled a checkmark V is displayed on the Options menu immediately preceding the Grids command When the grid pattern is disabled the checkmark is not displayed SPECIAL CONSIDERATIONS None EXAMPLE Accelerator key version Assumes that the grid pattern is initially disabled KEYSTROKE COMMENT ALT G Enable grid pattern ALT G Disable grid pattern ALT G Enable grid pattern Etc Etc 81
74. fferent background gridline user annotation and waveform colors from among 16 choices ACTIVATING PROCEDURE A different palette can be displayed by selecting either the Next Palette or the Previous Palette command from the View menu These commands allow you to pan through and display all 16 palette selections in either a forward or backward direction DO Display the Next Palette Forward Direction 1 Point to the View menu and drag down to Next Palette This displays the next pre defined display palette Consecutive activation of this command displays all 16 palette selections updating the display each time the command is selected Display the Previous Palette Backward Direction 1 Point to the View menu and drag down to Previous Palette This displays the previous pre defined display palette Consecutive activation of this command displays all 16 palette selections updating the display each time the command is selected Y Display the Next Palette Forward Direction 1 Choose View Next Palette ALT V N This displays the next pre defined display palette Consecutive activation of this command displays all 16 palette selections updating the display each time the command is selected Display the Previous Palette Backward Direction 1 Choose View Previous Palette ALT V P This displays the previous pre defined display palette Consecutive activation of this command displays all 16 palette selections updating the display
75. give meaning to the displayed data Instead of volts your data can be scaled annotated and displayed in significant engineering units 1 e PSI RPM Ibs ft s etc Calibration is done primarily for display purposes it makes the data more visually appealing and easier to understand on your monitor However when data is recorded or acquired to disk it is not completely independent of this calibration information you have provided When data is recorded it is stored to disk in a data file in the form of A D converter counts These A D converter counts are stored in a data file regardless of whether you provided calibration information or not However when you calibrate the calibration information is saved in an accompanying header file while your data is being stored in the data file This header file saves the calibration information allowing it to be re used when you review the data in WINDAQ Waveform Browser or if you append data to the same acquisition file thus eliminating the need for you to calibrate again The high low method allows waveform data in the form of ADC counts to be scaled and annotated in significant engineering units using any known or verified transducer output values The high low method is the easiest and most flexible method of calibrating data For example suppose you were acquiring pressure data with a transducer that had a known output of 1 volt at O PSI and 4 5 volts at 100 PSI Whether these output levels wer
76. hannel gain is changed or the channel is recalibrated Changing the trigger conditions with the Oscilloscope Mode dialog box also affects the Acquisition Triggering conditions and vice versa even though the modes trigger on different channels KEYSTROKE EXAMPLE KEYSTROKE COMMENT CTRL F1 Select the scroll mode No accelerator keystrokes for the oscilloscope mode 51 WAVEFORM RECORDING WITH WINDAQ Tach EVENT MARKER FUNCTION FUNCTION Allows you to insert event markers either commented or uncommented at any point in the data stream going to disk Event markers along with appropriate comments can be used to mark an event or flag an uncommon occurrence in the data stream going to disk thus providing a complete record of what happened and why After the data acquisition session WWB Tach playback software allows you to automatically search and move to the point in the data file where the event markers were placed during data acquisition refer to the SEARCH FOR EVENT function of the WINDAQ Waveform Browser playback software user s manual for more details ACTIVATING PROCEDURE A transition from the SET UP or STBY operating mode to the RECORD operating mode automatically inserts a positive going time and date stamped event marker in the data stream going to disk thus marking the start of acquisition You must be in the RECORD mode to insert additional event markers into the data going to disk E While in the RECORD operating mode
77. he Edit menu Refer to the Sample Rate Selection Function for complete details Waveform Compression Allows you to compress the waveform display on your monitor This is done by varying the number of data points that are used to display the real time waveform on your monitor Increasing the compression factor causes the display to plot less often which results in a slower real time display the waveform is being displayed at a fraction of the selected sample rate This feature is only a graphics adjuster that only affects how the display looks on your monitor Data acquired to disk is independent of these adjustments and is always recorded continuously to disk uncompressed When this button is activated the Compression dialog box appears prompting you to specify a compression factor 1 to 65 536 This button is the same as choosing Compression from the Edit menu Refer to the Waveform Compression Function for complete details Commented Event Marker Allows you to insert a commented event marker at any point in the data stream going to disk You must be in the RECORD mode recording waveform data to disk to insert commented event markers When this button is activated the Event Marker Comment dialog box appears prompting you to specify a 39 character comment that will be associated with the event marker The event marker is anchored at its position in the data file the instant the button is activated Data recording to disk continues wh
78. he WINDAQ Tach DATA STORAGE FORMAT chapter in the WINDAQ Waveform Browser manual for detailed information related to the WINDAQ Tach file header The maximum file size that may be specified is equivalent to the amount of space available on the target disk drive in bytes Data acquisition to disk may also be enabled and disabled remotely through digital input port DII Refer to the REMOTE CONTROL function in this chapter for further information As data is being recorded to disk the amount of file space consumed is displayed in the Storage field of the status bar as a percentage of total file space consumed 29 WAVEFORM RECORDING WITH WINDAQ Tach Each time data recording to disk is activated an event marker is automatically inserted in the waveform stream This feature allows data acquisition break points to be reviewed through WINDAQ Waveform Browser playback software Refer to the EVENT MARKER FUNCTION in this manual and the SEARCH FOR EVENT function in the WINDAQ Waveform Browser playback manual for further information related to event marker operation AUTOMATIC RECORDING MODE It is possible to force WINDAQ Tach to immediately start acquiring data to disk upon start up thus bypassing the File Open procedure and file size specification Windows allows you to consolidate these preliminary recording steps 1 e choosing File Open specifying a file name specifying a file size and choosing File Record by creating a new shortcut
79. he status bar Y Choose Edit Channels ALT E C This displays the channel selection grid as follows Channel Selection Each box in this grid represents an input channel An input channel is enabled by clicking the desired box Where in the grid you click which mouse button you click with and how many times you click the mouse button determines whether the input channel is enabled for differential operation for operation defined by the 5B module if used or for differential operation between a pair of channels automatically defined by the grid Since there are so many variables each instrument will be presented individually 38 WAVEFORM RECORDING WITH WINDAQ Tach Enable single ended Channels DO Point to the box in the grid that represents the desired channel and click the left mouse button to enable the channel as a single ended input or as an input defined by the 5B module when used A checkmark v is displayed in the desired channel box indicating that a single ended input has been enabled A second activation removes the checkmark and thus disables the channel Enable differential Channels Point to the box in the grid that represents the desired channel and double click the left mouse button to enable a pair of differential channels for differential operation this allows you to see the difference between 2 differential input channels A plus sign is displayed in the desired channel box indicating one diffe
80. his case the command buttons function exactly the same as described above However the calibration or set up parameters can be saved by first selecting the Cancel button followed by SAVE DEFAULT SETUP from the File menu then selecting the OK button EXAMPLE KEYSTROKE COMMENTS ALT F X Exit WINDAQ Tach OK or Cancel As required 71 WAVEFORM RECORDING WITH WINDAQ Tach RANGE OF CHANNELS FEATURE FUNCTION This feature consists of three separate functions that allow you to conveniently monitor and manipulate all the channels you have enabled when they can t be displayed on the monitor all at once These functions are most useful when many channels are enabled such as with a slave expansion instrument or with an EXP Series channel multiplexer and the size of your monitor or the amount of screen space devoted to the WINDAQ Tach window prevents you from seeing them all These functions are similar to the VARIABLE WAVEFORM ASSIGNMENTS function in that they allow you to assign any enabled channel to a specific display window however these functions allow you to assign or manipulate a block of channels while the VARIABLE WAVEFORM ASSIGNMENTS function only allows one channel assignment at a time Each item is described as follows ACTIVATING PROCEDURE Assign Range This function is similar to the VARIABLE WAVEFORM ASSIGNMENTS function in that it allows channel assignment to a specific display window however this function allows you to as
81. icates the active area of the dialog box the next action you perform will occur in this area Type the desired engineering unit value for the high calibrator 2 Press the TAB key twice to position the insertion point in the Low Calibrator Engr Value dialog box Type the desired engineering unit value for the low calibrator 3 Press the TAB key again to position the insertion point in the Engr Units dialog box Type up to a four character optional engineering unit tag 1 e PSI f s rpm etc There are also two option buttons for the High and Low Calibrator values High Calibrator O Baseline i Full Scale U Baseline Full Scale These option buttons allow you to calibrate negative only positive only or bipolar signals For example when you are acquiring a signal that is bipolar you would select the Full Scale High Calibrator and Full Scale Low Calibrator options When the signal you are acquiring is always negative choose the Baseline High Calibrator and Full Scale Low Calibrator options When you are acquiring a signal that is always positive such as RPM choose the Full Scale High Calibrator and Baseline Low Calibrator options The Next and Previous command buttons allow you to step through all of the enabled channels in order calibrating each enabled channel without closing this dialog box Note that when either the Next or Previous button is activated the channel number in the title bar of
82. ile you enter your comment This button is the same as choosing Insert Commented Mark from the Edit menu Refer to the Event Marker Function for complete details Show Hide Grid Enables disables the display of the real time waveform grid This button is the same as choosing Grids from the Options menu Refer to the Screen Grid Pattern Control Function for complete details Change Palette Allows you to change the display color schemes When this button is activated the User Palette dialog box appears prompting you to select background grid lines and user annotation first waveform and or second waveform colors This button is the same as choosing User Palette from the View menu Refer to the Palette Selection Function for complete details Expand Waveform 2x Allows you to scale expand the specified waveform two times its original size in amplitude When this button is activated the waveform is expanded two times its original size in amplitude Subsequent activations of this button continue to expand the waveform 2x in amplitude Note that the waveform limits and value change as well This button is the same as choosing Grow 2X from the Scaling menu Refer to the Waveform Display Scaling and Offset Function for complete details Shrink Waveform 2x Allows you to scale contract the specified waveform one half its original size in amplitude When this button is activated the waveform is contracted one half its original size in amp
83. ils Open Close File Allows you to open an existing file or to create a new file When this button is activated the Open dialog box appears prompting you to specify a file name to create a new file or to select an existing file to append to it When a file is open a second activation of this button closes the file Note that you are not yet recording data to disk you have only opened or assigned a name to a data file This button is the same as choosing Open from the File menu Refer to the Acquire Data To Disk Function for complete details Start Stop Recording Allows you to start or stop recording to disk When this button is activated without a data file open the Open dialog box appears prompting you to specify a file name to create a new file or to select an existing file to append to it When the file name is specified recording is started When this button is activated with a data file already open recording starts immediately A second activation of this button stops recording to disk but keeps the data file open Subsequent activations of this button toggles between record and stop Note that you can start and stop recording to disk as many times as you like This button is the same as choosing Record from the File menu Refer to the Acquire Data To Disk Function for complete details Enable Channels Allows you to enable channels for recording and to specify whether these channels are configured for single ended
84. ious parts of Help by choosing buttons in the Help window and commands from the Help menu When you are working in acquisition you can get help any time you want it You can request Help in a couple of different ways e From the Help menu choose a Help category by Pointing to the Help menu and dragging down to the desired menu item Choosing ALT H and then the desired underlined character e Use the cursor control keys to highlight or select an item on a menu and then press F1 to get context sensitive help on the item While in Help you can move to other topics to find exactly the information you want including help on Help how to use Help If you are new to Help it is strongly recommended that you view Help Basics from the How to Use Help category When you finish using Help you can leave the Help window open but out of your way or you can close the Help window Because Help is an application that appears in its own window you can display the Help information next to the window in which you re working As you work you can switch to the Help window and find the Help information you need for a particular task To exit Help choose File Exit from the Help window If you want to return to your work without closing Help you can shrink Help to an icon by clicking the Minimize button or by choosing Control Minimize SPECIAL CONSIDERATIONS None EXAMPLE Accelerator key Version KEYSTROKE COMMENT ALT H H Display the Help
85. ired maximum sample rate When the desired maximum sample rate is entered close the dialog box by D Clicking the OK command button Pressing the ENTER key Event Mark Capacity Allows you to set the maximum number of event mark entries available for a given data acquisition session from when recording is selected to when stop is selected If a large number of event mark entries are made setting the capacity higher will make more memory available to WINDAQ Tach for the next start up Valid entries range from 1024 to 16 384 The default value of 1024 is generally sufficient for most users Each event marker and each comment require one entry apiece while two entries are required each time acquisition is started either manually or remotely 68 WAVEFORM RECORDING WITH WINDAQ Tach To specify the maximum number of event marks 1 Point to the Edit menu drag down to Preferences and release the left mouse button 2 Inthe Edit Preferences submenu click Event Mark Capacity Q Choose Edit Preferences Event Mark Capacity ALT E P E This displays the following dialog box Number of ewent mark entries per manual start Maximum number of entries 1024 OK Cancel Enter in the text box the desired maximum number of event mark entries When the desired number is entered close the dialog box by D Clicking the OK command button Pressing the ENTER key Open New File on Full Enables disables the
86. l annotation for each channel without closing this dialog box When all annotation has been entered click OK to assign the annotation to each channel Clicking Cancel closes the Channel Annotation dialog box without assigning any annotation Once the channel annotation is entered the display of user annotation can be toggled on or off with the User Annotation command on the Options menu SPECIAL CONSIDERATIONS As you assign various A D channels to different waveform windows the channel s annotation rides along with the channel User supplied channel annotation is written to the data file along with the acquired waveform Only enabled channels may be annotated Refer to the CONFIGURE ADC CHANNELS FUNCTION section of this chapter EXAMPLE KEYSTROKE COMMENTS F11 Select the User Annotation function 1 Select channel one annotation This is a test Enter as channel one annotation This is a test ENTER Return to normal WINDAQ Tach screen 90 WAVEFORM RECORDING WITH WINDAQ Tach VARIABLE WAVEFORM ASSIGNMENTS FUNCTION Allows any enabled ADC channel from 1 32 to be assigned to a specified display window ACTIVATING PROCEDURE WINDAQ Tach supports up to 32 waveform display windows 1 through 9 A B C D E F G H I J K L M N O P Q R S T U V W in which any one of 32 channels may be displayed In some cases any two waveforms may be displayed in an overlapping format within the same window refer to
87. lapped 3 Number of displayed channels 8 amp 4 overlapped Number of displayed windows 8 5 amp 6 overlapped 7 amp 8 overlapped Display Format 9 ofr el S pray B amp C overlapped DI 200 Acquisition Channels E Cenpress F7 100 zjorage 4 used Frames s Eo Edit View Scaling Options Hele D amp E overlapped F amp G overlapped Number of displayed channels 16 Number of displayed windows 16 Display Format 10 DI 220 Acquisition File Edit View Scaling Options Help Mode Oscill Channels 40 es Fa aooo Status SET UP Waveform Windows 1 through 16 Number of displayed channels 16 Number of displayed windows 16 DISp Ay Format 11 User Poo DI 200 Acquisition Eile Edit View Scaling Options Help Hode Scroll Channels 0 Srs F3 10000 gon ress F7 100 Storag E used Frangs s 2 9570 By hay Or ns d i i eB eo me feet Sechan Lan E ed ee ae a cea ee a Number of displayed channels 32 Number of displayed windows 32 roii ms Sar S00 a Status SET Te 5 s CHAN Any non standard display 46 WAVEFORM RECORDING WITH WINDAQ Tach ACTIVATING PROCEDURE To enable a particular display format and display it on your computer s monitor DO 1 Point to the View menu and drag down to Format Screen In the format box click the desired display format Choose View Format Screen ALT
88. le To get back to the display you had prior to activating the Show Dynamic Range function use the Undo command on the Edit menu EXAMPLE Keystroke Comment ALT R Show dynamic range of waveform CTRL Z Undo the Show Dynamic Range function 82 WAVEFORM RECORDING WITH WINDAQ Tach TACHOMETER FUNCTION Allows the tachometer scaling factor to be entered in millimeters 10 0 by default with check boxes to allow specifying positive going instead of negative going pulses or a direction signal where negative going means forward ACTIVATING PROCEDURE Point to the Edit menu and drag down to Tachometer Y Choose Edit Tachometer ALT E T SPECIAL CONSIDERATIONS Edit Tachometer will be disabled once recording to a file has begun and may not be changed thereafter for that file EXAMPLE Keystroke Comment Alt T Edit distance between tachometer pulses 83 WAVEFORM RECORDING WITH WINDAQ Tach DISTANCE PER DIVISION FUNCTION FUNCTION Displays the distance per major division at the bottom of the real time screen as M DIV or KM DIV The displayed value is a function of the tachometer scaling factor Edit Tachometer and the selected waveform compression factor DI 720 Acquisition File Edit Yiew Scaling Options Help Channels 0 1 2 3 Compress hy ji 1 aterage a aa a a ee EsAN 250 H DI 680 0 Status SET UP Distance per major division ACTIVATING PROCEDURE None Distance per major division is displ
89. litude Subsequent activations of this button continue to contract the waveform one half in amplitude Note that the waveform limits and value change as well This button is the same as choosing Shrink 2X from the Scaling menu Refer to the Waveform Display Scaling and Offset Function for complete details Shift Waveform Up Allows you to offset shift the specified waveform 10 pixels up in amplitude from its current position When this button is activated the waveform is shifted up 10 pixels in amplitude Subsequent activations of this button continue to shift the waveform up by 10 pixels Note that the waveform limits and value change as well This button is the same as choosing Waveform Up 10 Pixels from the Scaling menu Refer to the Waveform Display Scaling and Offset Function for complete details Shift Waveform Down Allows you to offset shift the specified waveform 10 pixels down in amplitude from its current position When this button is activated the waveform is shifted down 10 pixels in amplitude Subsequent activations of this button continue to shift the waveform down by 10 pixels Note that the waveform limits and value 87 WAVEFORM RECORDING WITH WINDAQ Tach change as well This button is the same as choosing Waveform Down 10 Pixels from the Scaling menu Refer to the Waveform Display Scaling and Offset Function for complete details Scroll Mode Allows you to display waveform information on your monitor in a continuou
90. lt selecting a button from the ToolBox is no different than clicking on a menu and dragging down to the desired command both methods accomplish the same result Whether you should use the ToolBox or not is largely a matter of personal preference Some may find the ToolBox invaluable for saving steps while others won t want it taking up valuable display space on their monitors EXAMPLE None 88 WAVEFORM RECORDING WITH WINDAQ Tach UNDO FUNCTION FUNCTION Allows you to reverse the last screen scaling or offset operation performed on a selected channel When undone the waveform will revert back to the original values before the previous scaling or offset operation Note that this feature only works on the same channel as the most recent scaling or offset operation Subsequent undo operations toggles the waveform between the previous and most recent versions of screen scaling or offset ACTIVATING PROCEDURE A scaling or offset operation must first be performed on a selected channel to make the Undo command selectable undimmed Once Undo becomes selectable you can perform any other playback operation except another scaling or offset operation on any other channel and still have the capability to come back to the selected channel and undo the last screen scaling or offset operation After scaling or offsetting a waveform reverse the operation as follows DO 1 Point to the Edit menu and drag down to Undo Y 1 Choose Edit Und
91. lue by pressing the TAB key With WINDAQ Tach acquisition software the File Size dialog box shows the current pack factor which is the ratio of the original data file size to the data file size when different channels at different rates are employed This pack factor is used to calculate data file size or recording time Enter in the text box the desired file size in kilobytes or the desired distance in kilometers When the desired value is entered close the dialog box by 2 WAVEFORM RECORDING WITH WINDAQ Tach D Clicking the OK command button Pressing the ENTER key The Record function on the File menu is now enabled To start acquiring data to disk refer to the Recording Data to Disk heading below Creating a New File Enter in the File Name box the name of the data file to which WINDAQ Tach is to store data When the desired file name is entered close the dialog box by QO Clicking the OK command button Pressing the ENTER key After a valid file name is entered the following File Size dialog box is opened This dialog box provides a way for you to specify the maximum file size in kilobytes or the maximum recording distance in kilometers of the target data acquisition file File Size Ea Additional Size in KiloBytes 360 At a tachometer pulse every 10 000000 mm Recording Distance in kilometers 0 97160 concel_ At a tachometer pulse every 10 mm indicates the relationship of tachometer sig
92. mum size that may be specified is equivalent to the amount of space available on the target disk drive in bytes A file size using K nomenclature may be supplied The K designator is interpreted as being equal to 1024 For example if 100K is specified the file size created is 102400 1024 x 100 bytes It is not necessary to use K nomenclature when specifying data file size The actual size of the waveform data file ultimately created on disk following data acquisition depends on the following If WINDAQ Tach is terminated before the end of the data file is reached the size of the resulting data acquisition file will be less than that specified by filesize WINDAQ Tach data only consumes enough of the target file to contain its acquired waveform information releasing the excess If WINDAQ Tach is terminated without storing any data to disk a file will exist that contains only the WINDAQ Tach data file header This file may be deleted or used as a set up file to provide default conditions for another data acquisition file If WINDAQ Tach is allowed to acquire data to disk until the target data 30 WAVEFORM RECORDING WITH WINDAQ Tach acquisition file is full the file size of the target file may or may not be exactly equal to that specified in the command line The precise size depends upon the number of channels enabled during acquisition and whether this number is an even multiple of the specified file size When specifying
93. n file thus eliminating the need for you to calibrate again The fixed method allows waveform data in the form of ADC counts to be scaled and annotated in significant engineering units using minus full scale baseline or plus full scale values when a quantity per unit of measure rather than two calibration levels is known The fixed calibration method allows you to calibrate a waveform when a known linear input to output relationship exists for two of these three points full scale baseline or full scale For example suppose you were acquiring temperature signals and you were using a temperature to analog converter TAC With the two calibration level method you could probably determine the low calibration level such as zero or room temperature but you could not easily determine the high calibration level how hot is it going to get Since you have only one known calibration value it is not possible to calibrate the waveform using this approach However with the fixed method the TAC device itself offers a solution Say for instance the TAC you are using is a thermocouple to millivolt converter According to its specifications it accepts an input signal from a temperature sensor and outputs a linear 1 millivolt per degree analog voltage signal This 1mV degree input to output ratio is the key Since you know the relationship between voltage and the units you are measuring in this case temperature you can calibrate the waveform using
94. n on a specific channel 1 e up down scale offset etc that channel is enabled by pressing the letter or number of the display window containing the waveform When so specified the X Y annotation in the left right annotation margin will be highlighted indicating that waveform channel Y contained in waveform window X is enabled for operation Note that waveform window will in its default state always display the lowest enabled channel number Window 2 will default to display the second lowest enabled channel number and so on Comments Displays ADC channel two in waveform display window one Displays ADC channel sixteen in waveform display window one Displays ADC channel one in waveform display window one Displays ADC channel twelve in waveform display window two Displays ADC channel three in waveform display window ten Displays ADC channel sixteen in waveform display window four Displays ADC channel one in waveform display window four Displays ADC channel fourteen in waveform display window sixteen DI 200 Acquisition Channels Compress These are the Variable Waveform Assignment descriptors Note that in this example windows 1 2 3 and 4 are displaying waveform channel numbers 0 1 2 and 3 respectively 7 88 92 File Edit View Scaling Options Help Esci 250 O nD 80 0 Status SET UP WAVEFORM RECORDING WITH WINDAQ Tach WAVEFORM CALIBRATION FIXED METHOD FUNCTION WINDAQ Tach offers
95. nal to distance In the above illustration two bytes are written to the data file every 10 mm assuming a single channel is enabled This means that 360 kilobytes default value of data will be stored to disk in 0 9216 kilometers Note that modifying the Tachometer function which is found in the Edit pull down menu affects both the file size and recording distance If the relationship of distance to the Tachometer is unsatisfactory you can cancel out of this dialog box and adjust the relationship to your preference Note that you can create a new file by specifying either a maximum file size in kilobytes or a maximum recording distance in kilometers When a value is entered in one of the text boxes the other text box can be updated to display the other equivalent value by pressing the TAB key Enter in the text box the desired file size in kilobytes or accept the default When the desired file size is entered close the dialog box by DO Clicking the OK command button Pressing the ENTER key The Record function on the File menu is now enabled To start acquiring data to disk refer to the following procedure 28 WAVEFORM RECORDING WITH WINDAQ Tach Recording Data to Disk To start acquiring data to disk a Click the Start Stop Recording button in the ToolBox Point to the File menu and drag down to Record Y Choose File Record ALT F R This places you in the active record to disk operating mode where enabled analog cha
96. nd release the left mouse button 2 In the Edit Preferences submenu click Skip Factor Choose Edit Preferences Skip Factor ALT E P S This displays the skip factor dialog box Ratio of total points to those used for compression Skip Factor at maximum rate OR Cancel Enter in the text box the desired skip factor When the desired skip factor is entered close the dialog box by D Clicking the OK command button Pressing the ENTER key Buffer Size nonfunctional when used with serial port instrumentation Allows you to specify the size of input buffer needed for gap free data recording at the maximum sample rate By setting buffer size you can specify the 66 WAVEFORM RECORDING WITH WINDAQ Tach correct amount of memory for acquiring data gap free at your computer s maximum sample rate while simultaneously running your usual applications The input buffer is where the acquired data is temporarily stored If the ratio of sample rate to buffer size is too small the sample rate in the status bar is shown in reverse video This is a warning that you may not be able to reliably store data to disk To find the correct input buffer size refer to the Streaming Data to Disk flow chart in Appendix A The current size of the buffer can be seen in the Edit Sample Rate dialog box The amount of buffer space allocated is automatic proportional to the sample rate and generally not in need of manual adjustment Man
97. neither of the above applies or if you really want to tweak your real time display you can experiment with the scroll limit to find the most visually pleasing display Start with a scroll limit of 2 and keep doubling it up to the horizontal resolution of your monitor until the display appears and performs satisfactorily While it causes no harm there is nothing to gain by setting the scroll limit higher than the horizontal resolution of your monitor To specify a scroll limit 1 Point to the Edit menu drag down to Preferences and release the left mouse button 2 Inthe Edit Preferences submenu click Scroll Limit Q Choose Edit Preferences Scroll Limit ALT E P L This displays the Max Points to Scroll Instead of Repaint dialog box Scroll Limit OK Cancel Enter in the text box the desired scroll limit in pixels When the desired scroll limit is entered close the dialog box by D Clicking the OK command button 65 WAVEFORM RECORDING WITH WINDAQ Tach Y Pressing the ENTER key Skip Factor nonfunctional when used with serial port instrumentation Allows you to specify the ratio of the total number of data points to the number used for screen display at the maximum sample rate For example specifying a skip factor of 20 means that for every 20 acquired data points only 1 will be used for screen display purposes ratio of 20 1 Similarly a skip factor of 1 means every data point acquired will be used for s
98. ng will automatically continue but to a different file called RAU WDQ Similarly recording will automatically continue but to file RAT WDQ when RAU WDQ reaches full size The last character of the filename excluding the file extension if any is the character that is incremented decremented Last character of filename excluding extension gets incremented RA WDQ full or old filename RAU WDQ new filename If a file with the new name already exists the file is automatically deleted before the new one is opened There is a discontinuity between the data at the end of one file and the start of the next but it is short if your computer system is not busy with other tasks such as reading disk drives or printing If the Open New File on Full preference is also selected and the old filename excluding extension ended in numeric digits e g WEASELI WDQ the numeric portion is automatically incremented e g WEASEL2 WDQ If the numeric suffix of the old name is all nines e g WEAS9999 WDQ the new name will wrap back to all zeroes without incrementing the preceding character e g WEASO000 WDQ To enable this preference if disabled or disable it if enabled 1 Point to the Edit menu drag down to Preferences and release the left mouse button 2 Inthe Edit Preferences submenu click Record Next File on Full o Choose Edit Preferences Record Next File on Full ALT E P R When enabled a checkmark V is displaye
99. nitor In the SET UP mode the Record function on the File menu is dimmed until a file name is specified After all aspects of the waveform are configured and you are ready to record data to disk you must assign a file name to enable the Record function This is done as follows al B Click the Open Close File button in the ToolBox Point to the File menu and drag down to Open Choose File Open ALT F O This displays the Open dialog box It is here that you specify a file name to create a new file or open an existing file to append to it Current directory Look in J TACH amp ce List of WinDaq je E ample wt files in current directory text box gt Files of type JwinDaq Files DT Cancel Help Z Appending to an Existing File In the File Name list box double click the name of the file you want to open 1 In the File Name text box type the filename or press the TAB key then the T or J key to select the filename 2 Press ENTER If the file you want is not listed in the File Name box select a new drive or directory in the Open dialog box If the file you want is not a WINDAQ Tach file select a different type of file in the List Files of Type box 26 WAVEFORM RECORDING WITH WINDAQ Tach D Do one of the following If the file is To display its name in the File Name box In a different subdirectory Double click the directory in the Directories box On a differe
100. nnel data is digitized displayed and streamed to disk simultaneously The status field in the bottom annotation line indicates RECORD To stop acquisition to disk Click the Start Stop Recording button in the ToolBox Point to the File menu and drag down to Stop Choose File Stop ALT F T This suspends data storage to disk but the real time display remains active The status field in the bottom annotation line indicates STBY when acquisition has been stopped Note that the Stop function on the File menu only becomes enabled when in the record to disk operating mode Data acquisition to disk may be started and stopped as many times as you desire When the target data file has been filled data acquisition to disk will cease the Storage field of the status bar will display 100 used and the Status field of the status bar will display FILE FULL SPECIAL CONSIDERATIONS If the sample rate is displayed in reverse video when you attempt to acquire data to disk then you may not be able to reliably store data to disk Refer to Appendix A Different Ways of Allocating Memory for more details File Edit Miew Scaling Options Help Mode seroll Channels U 1 Ss Fale Com ress TP Reverse video oe ee ee ee ee ee eee ek vee ee oe The default file size is 360kKB 368 640 bytes The minimum file size that may be specified is 1 156 bytes which is equivalent to the size of the WINDAQ Tach file header refer to t
101. nt drive Click the arrow in the Drives box and then click the drive letter Of a different file type Click the arrow in the List Files Of Type box and then click the type of file Y Press ALT D to select from the Directories box ALT V to select from the Drives box or ALT T to select from the List Files of Type box When the desired file is selected the following confirmation box appears DIZ00AC ES N File already exists Do you want to append to it Choosing No aborts the file open procedure Choosing Yes invokes the following File Size dialog box which allows you to specify in either kilobytes or time how much additional data to add to the end of the file File Size Fa Additional Size in Kilobytes 360 At a tachometer pulse every 10 000000 mm Recording Distance in kilometers 0 92160 Cance At a tachometer pulse every 10 mm indicates the rate at which the file is being written to as a function of the tach signal When appending to an existing file this relationship cannot be changed In the above illustration the tachometer is active every 10 mm This means that 360 additional kilobytes of data will be appended to the original file in a distance of 0 9216 kilometers Note that you can append to a file by specifying either a file size in kilobytes or a recording distance in kilometers When a value is entered in one of the text boxes the other text box can be updated to display the other equivalent va
102. o ALT E U SPECIAL CONSIDERATIONS None ACCELERATOR KEY EXAMPLE Assumes a scaling or offset operation has been performed KEYSTROKE COMMENTS CTRL Z Undoes the last scaling or offsetting operation CTRL Z Undoes the last undo action a redo Etc Etc 89 WAVEFORM RECORDING WITH WINDAQ Tach USER CHANNEL ANNOTATION FUNCTION FUNCTION Allows you to custom annotate up to 30 characters each display channel Used in tandem with the User Annotation function on the Options menu you can display a different message on the baseline of each channel ACTIVATING PROCEDURE The desired channel annotation must first be entered before it can be toggled on or off To enter channel annotation Point to the Edit menu and drag down to User Annotation Choose Edit User Annotation ALT E U This displays the Channel Annotation dialog box as follows Channel Annotation x Channel Annotation Your Message Here Next Previous Cancel This dialog box prompts you to enter the desired channel annotation for the currently selected channel or any other channel If not the currently selected channel enter the desired channel number for which you want to provide annotation in the Channel text box In the Annotation text box enter the desired annotation up to 30 characters The Next and Previous command buttons allow you to step through all of the enabled channels in order entering the desired channe
103. ocation stamp will be automatically generated using 2 trailer items toward the maximum of 16 384 allowed per manual start in Edit Preferences Event Mark Capacity Each user generated commented event mark uses 2 trailer items The WINDAQ Tach application is named DIZ00TNT EXE instead of DI200ANT EXE and File Browse executes WWB Tach WINDAT32 EXE instead of WINDAQ32 EXE The help files DIZO0OTNT HLP and 23 WAVEFORM RECORDING WITH WINDAQ Tach WINDAT32 HLP are named for their corresponding applications A special tachometer scanning process DISCN740 EXE in WINDOWS SYSTEM or WINNT S YSTEM372 is used instead of the usual DISCN720 EXE from WINDAQ Pro but DI740NT DLL is just the normal DI720NT DLL renamed to launch the special DISCN740 EXE The other processes DICMP740 EXE and WDQDK740 EXE are just renamed copies of the usual DICMP720 EXE and WDQDK720 EXE The default extension for WINDAQ Tach is WDT to distinguish them from WDQ files and WWB Tach should be associated with this extension in My Computer View Folder Options File Types WINDAQ Tach and WINDAQ Pro can coexist in the same directory if the user is careful to avoid Options Triggered Mode Triggered Storage Remote Storage and Remote Events File Save Default Setup from WINDAQ Pro will destroy the Edit Tachometer calibration but it can be restored manually or by reading a WDT reference file If you plan to use WINDAQ Pro for much more that checking out the hardware when tachometer problem
104. of free time to handle other tasks but the real time display suffers With this preference item you can trade display performance for system time availability experimentation is encouraged Decide which is more important visually pleasing display performance or multitasking capability and adjust the update interval accordingly To specify a minimum screen update time D 1 Point to the Edit menu drag down to Preferences and release the left mouse button 2 Inthe Edit Preferences submenu click Update Interval o Choose Edit Preferences Update Interval ALT E P D This displays the Minimum Milliseconds Between Updates dialog box Minimum Milliseconds Between Updates Interval OK Cancel Enter in the text box the desired interval in milliseconds When the desired interval is entered close the dialog box by O Clicking the OK command button Pressing the ENTER key 64 WAVEFORM RECORDING WITH WINDAQ Tach Scroll Limit Allows you to specify the maximum width in pixels of discontinuity from the right edge of the screen If you do not see any discontinuity in the display the scroll limit is adjusted properly for your computer and your typical operating conditions If you do see some display discontinuity you can adjust the scroll limit to compensate for the discontinuity and improve the appearance of your display It should be noted that this preference item is simply a graphics adjuster that onl
105. of viewing and to keep a high degree of detail you want only 8 displayed at a time on your monitor You can use the Backward Range command to conveniently scroll backward through the remaining channels of data Just select Backward Range from the View menu or use the CTRL UP ARROW accelerator keystroke The next lower numbered 8 channels will be displayed SPECIAL CONSIDERATIONS These functions are most useful with slave expansion instruments or with an EXP Series multiplexer 73 WAVEFORM RECORDING WITH WINDAQ Tach SAMPLE RATE SELECTION FUNCTION Use the Sample Rate Selection Dialog Box to define the rate at which the tachometer signal is sampled Sample Rate should be chosen to be proportional to the pulse width of the active part of the tachometer signal as follows Le Active Portion of Tachometer Signal t pulse width of tachometer n number of channels j Sample Rate Hz T ene2 For example a tachometer signal with an active pulse width of 1 millisecond requires a sample rate of 4 kHz when applied to a data acquisition application that acquires two channels Win software has been tested to a maximum sample rate of 40 000 samples per second which we believe to be amply sufficient for most applications however it s very possible that the software is capable of faster sample rates by at least a factor of 2 ACTIVATING PROCEDURE To specify a sample throughput rate Fate nur a Click the Sample Rate button in the
106. ollows 1 The SET UP operating mode enabled 2 Waveform storage to disk disabled 3 One channel enabled channel 0 configured for single ended operation 4 One waveform channel displayed 5 Oscilloscope display mode enabled 6 Channel 0 scale set to 5 volts full scale 7 Channel O screen full scale and base line annotation enabled 8 Waveform window 1 is assigned to channel 0 annotated as 1 0 in the left annotation margin 9 The sample rate is set to 100 samples per second 10 The waveform compression factor is set to 1 WAVEFORM RECORDING WITH WINDAQ Tach THE WINDAQ Tach WAVEFORM ACQUISITION WINDOW The typical WINDAQ Tach acquisition window consists of six fundamental components the title bar menu bar status bar left right annotation margin waveform strip area and the bottom annotation line These components are shown in the following illustration Menu bar gt Eile Edit View Scaling Options Help Mode Oscill channels 0 1 i Se ea ees F3 2000 compress FY 1 storage 4 used Status ar 5 0000 Left annotation margir ag Waveform strip area Bottom annotation line S s CHAN 1000 mA DIV 20 Status SET UP Title bar The title bar has two purposes it identifies a file through the file name and it serves as a visual cue that the window may be moved or manipulated The title bar consists of two parts the window title and the window sizing icons a Window title Window sizing
107. ommand on the Edit menu The Disk Buffer Size in KiloBytes value is also displayed for informational purposes only and can not be directly adjusted by the user It indicates the size of the disk buffer which is a temporary storage place in cheap or easily attainable non contiguous memory for the acquired data before being written to disk However with WINDAQ Tach you can directly adjust or modify buffer size and sample rate two factors that govern gap free data acquisition The Preferences command on the Edit menu allows you to specify a buffer size ranging from 16kB to 128kB The larger the buffer size the greater the chance of acquiring gap free data at the maximum sample rate your computer can achieve However the larger the buffer size the more memory it uses thus leaving less perhaps not enough for running other programs If you never run other programs simultaneously with WINDAQ Tach then conserving memory is not an issue However if you like to run WINDAQ Tach simultaneously with a spreadsheet program or a data analysis program then you must limit the amount of memory allocated to the input buffer so the other applications have enough memory to run The dialog box shown above allows you to specify sample rate The sample rate used to determine buffer size is the old or previous sample rate value before any changes were made with this dialog box The amount of buffer space allocated is proportional to the sample rate WINDAQ
108. ommented manual start and the subsequent stop A total of 8 191 may be activated with comments only or with remote start time and date stamps only The actual comments you enter are contained in separate memory and therefore consume only one entry apiece and each manual start produces at least one event marker with a time and date stamp activated automatically by WINDAQ Tach upon the initiation of waveform recording to disk EXAMPLE KEYSTROKE COMMENT F4 Begin recording CTRL Space bar Enable uncommented event marker 53 WAVEFORM RECORDING WITH WINDAQ Tach SHIFT Space bar Enter comment CTRL F4 SHIFT Space bar Enter comment F4 Enable commented event marker Control period 1 event marker comment Suspend recording Specify annotation for next automatically inserted event marker Control period 2 comment for next automatically generated event marker Resume recording event marker is automatically enabled and associated with comment Control period 2 54 WAVEFORM RECORDING WITH WINDAQ Tach FAST SCROLL FUNCTION FUNCTION When enabled this option causes the display to scroll only in multiples of 16 pixels Useful when scrolling speed is limited by display hardware Scrolling by 16 pixels is the result of manipulating the display software in whole word chunks rather than individual bits This is the optimum condition for display scrolling The advantage of these whole word manipulations is they t
109. on OR 1 Drag in the waveform strip area to draw a selection rectangle The selection rectangle is used to expand the waveform to a specific size in the amplitude direction within the limits defined by the A D converter The top and bottom edges or the vertical limits of the selection rectangle will dictate the amount of waveform expansion 2 Click the left mouse button in the right or left annotation margin The waveform will be expanded to full strip size with the vertical selection rectangle limits now defining the full scale values for the waveform Choose Scaling Grow 2X ALT C G This expands the specified waveform two times its original size in the amplitude direction Contracting the specified waveform Le Click the Shrink Waveform 2x button in the ToolBox DO Point to the Scaling menu and drag down to Shrink 2X This contracts the specified waveform one half its original size in the amplitude direction OR Point to the right or left annotation margin and click the right mouse button This also contracts the specified waveform one half its original size in the amplitude direction OR 105 WAVEFORM RECORDING WITH WINDAQ Tach 1 Drag in the waveform strip area to draw a selection rectangle The selection rectangle is used to contract the waveform to a specific size in the amplitude direction within the limits defined by the A D converter The top and bottom edges or the vertical limits
110. onnect adapter cable 100679 to this Expansion Out connector Once the cable is connected to the expansion port the pinout on the D sub end will be the same as with the DI 720 tachometer input connects to DI1 Pin 6 and direction input connects to DIO Pin 25 WAVEFORM RECORDING WITH WINDAQ Tach REFERENCE INFORMATION CONVENTIONS USED IN THE DOCUMENTATION Before you start using WINDAQ Tach it s important to understand the terms and notational conventions used in this documentation General Conventions e Commands you choose are given with the menu name preceding the command name For example the phrase Choose File Open tells you to choose the Open command from the File menu This naming convention describes the sequence you follow in choosing a command first you select the menu then you choose the command e WINDAQ Tach functions are presented with both mouse and keyboard procedures and where applicable with the corresponding ToolBox button When separate mouse and keyboard procedures are listed for a function you can identify each procedure by the mouse or keyboard icon The mouse icon represents procedures that are accomplished using the mouse and the keyboard icon represents procedures that are accomplished using the keyboard The button icon represents the procedure accomplished with the ToolBox O Mouse icon Keyboard icon Al ToolBox button icon typical Mouse Conventions In general most WIN
111. op and bottom chart edge values in their respective text boxes The Next and Previous command buttons allow you to step through all of the enabled channels in order entering the desired display limits for each channel without closing this dialog box Note that when either the Next or Previous button is activated the channel number in the title bar of the dialog box changes to indicate the channel for which you are currently setting display limits 3 Complete the chart edge value entry as follows Click OK Press the TAB key until a bold border surrounds the OK command button indicating selection and press ENTER Your specified values will now be displayed on the upper and lower chart edges and the waveform will be automatically scaled to fit the new values SPECIAL CONSIDERATIONS The value of engineering units may range from 1 0 E 32 to 1 0 E 32 95 WAVEFORM RECORDING WITH WINDAQ Tach DI 720Series Maximum Measurement Maximum Measurement 100 000 10mV Example Suppose we are using a DI 730 to acquire pressure data and we are using a converter device that accepts an input signal from a pressure sensor and outputs a linear 1 millivolt per PSI analog voltage signal We want to acquire pressure data in the O to 100 PSI range a What gain range should we select b What input configuration should we select c What should our calibration values be a Since the converter device that we are using has a 1 millivolt
112. orm that rides the window baseline the signal seems to disappear but it is merely the same shade as the baseline Selecting the monochrome color scheme ensures that your monitor will show every shade it is capable of showing without any conflicts Color Selection Conflicts When selecting color combinations it is important to note that the cursor color not modifiable will always be the inverse of the color chosen for the background For example if the background color is black the cursor color will be white or if the background color is red the cursor color will be dark cyan For this reason do not pick the inverse color of the background for grid lines and user annotation If you do the cursor will seem to disappear when 62 WAVEFORM RECORDING WITH WINDAQ Tach coincident with a vertical grid line As a general rule do not assign the inverse color of the background to any other parameter grid lines and user annotation Ist waveform or 2nd waveform and do not make both waveforms the same color EXAMPLE Accelerator key version assumes an initial palette state of 0 KEYSTROKE COMMENTS ALT P Move to palette number 1 ALT P Move to palette number 2 ALT SHIFT P Move back to palette number 1 ALT SHIFT P Move back to palette number 0 63 WAVEFORM RECORDING WITH WINDAQ Tach PREFERENCES FUNCTION Selecting this command displays a submenu of rarely changed configuration items When selected these items allow you to adjust WIN
113. orm the differential channel pair have not already been added to the list as single ended channels If such is the case the single ended channel already specified will be deleted from the list and the new differential channel added Differential channel numbers greater than 8 are not recognized as valid entries WINDAQ Tach always sequentially samples from the lowest channel number specified to the highest Checkmarks do not have to be placed sequentially You can sample only channels 3 8 and 9 for instance if those are the channel blocks that are enabled The number or type of channels enabled for acquisition cannot be changed after the RECORD mode has been activated 39 WAVEFORM RECORDING WITH WINDAQ Tach COPY FUNCTION FUNCTION Copies the graphics in the graphic selection rectangle to the clipboard ACTIVATING PROCEDURE Graphics are copied to the clipboard using the mouse the Copy command on the Edit menu and the graphic selection rectangle The Copy command on the Edit menu is dimmed until a graphic selection rectangle is drawn thus enclosing the desired graphics The graphics selection rectangle is drawn by positioning the mouse pointer anywhere in the waveform strip area and dragging with the right mouse button until the rectangle encloses the desired graphics When the right mouse button is released the rectangle remains fixed in size on the screen With the graphics rectangle drawn the Copy command on the File menu is enable
114. ough 7 displayed as a vertical line and a check mark is displayed on the Scaling menu immediately preceding the Digital Plot command For example display window 1 of the following illustration shows a digital plot of a digital input channel The vertical line indicates a high condition on bits 2 and 6 The absence of the vertical line on bits 2 and 6 indicate a low condition Display window 2 shows an analog plot of the same two input bits 42 WAVEFORM RECORDING WITH WINDAQ Tach File Edit View Scaling Options Help Digital input bit 2 Digital input bit 6 To enable a digital plot of a digital input channel DO 1 Point to the Scaling menu and drag down to Digital Plot Y 1 Choose Scaling Digital Plot ALT C T This displays the Channel X Digital Input Inversions dialog box where X represents the enabled channel in this example it is channel 0 Channel 0 Digital Input Inversions M DIO Check each input to be plotted when low instead of MDI high if selected for digital viewing M Dle M DI3 M DIA M DIS M DIG M DI cancel It is here that you can invert the digital input bit line display to accommodate your preference The default configuration shown by a check mark in the desired digital input box is a dark line on a light background for a high signal condition and no line for a low signal condition Clicking in the digital input box removes the X and inverts the line display a ligh
115. ow immediately start recording with WINDAQ Tach by clicking the Start button on the taskbar and then clicking the name you chose in step d should be at the top of the Start Menu To modify the existing WINDAQ Tach program item a Inthe Start Menu window double click the Programs icon The Programs dialog box appears b Double click the WINDAQ item or whatever you named the destination directory for WINDAQ files during the installation c In this dialog box click the right mouse button on the WINDAQ Tach icon and click Properties The WINDAQ Tach Properties dialog box appears d Choose the Shortcut tab if not already displayed e In the Target text box add to the end of the statement at a minimum the target file name and the A switch in the following order d path di200tnt exe d path targetfilename filesize F d path setupfile A Refer to step 3b above for an explanation of the arguments 31 WAVEFORM RECORDING WITH WINDAQ Tach f Click the OK button The dialog box closes and the new shortcut icon appears in the Start Menu window You can now immediately start recording with WINDAQ Tach by clicking the Start button on the taskbar pointing to Programs pointing to WINDAQ and then clicking the WINDAQ Tach icon SLAVE MODE It is possible to run WINDAQ Tach in a slave mode where some other application controls WINDAQ Tach and at the same time prevents the user from doing so It is also possible to send messages
116. play can be paused This allows you to get a stationary look at some point on the waveform While paused the Mode field in the status bar changes from the chosen display mode to Paused To enable disable the waveform display pause feature DO Point to the Options menu and drag down to Pause Graphics Choose Options Pause Graphics ALT O P When the pause feature is enabled a subsequent pause attempt disables the pause feature The display mode that was active before pausing is restored When Oscilloscope Mode is chosen the Oscilloscope Triggering dialog box is displayed as follows 49 WAVEFORM RECORDING WITH WINDAQ Tach Oscilloscope Triggering x Channel Level 00 LSB olope ma M Free Run 0 M Erase Bar Set Level Cancel This dialog box allows you to choose between a triggered sweep oscilloscope display or a free running oscilloscope display Checking the Free Run check box selects the free running oscilloscope display Leaving the Free Run check box unchecked selects the triggered sweep oscilloscope display If free running is selected the waveform is displayed constantly on your monitor in a manner identical to an oscilloscope display and the rest of this dialog box can be ignored If triggered sweep is selected you can also set display trigger conditions such as channel level and slope that define the trigger or starting point for displaying the waveform on your monitor In this mo
117. played windows 2 Display Format 4 DI 200 Acquisition Be File Edit View Scaling Options Help i ge ki Mode Scroll Channels 0 F3 10000 Compress F7 Waveform Windows 1 amp 2 overlapped 3 amp 4 overlapped Number of displayed channels 4 Number of displayed windows 4 Display Format 6 D200 Acquisition Scaling Options Help Channels 0 File Edit View Waveform Windows 1 amp 2 overlapped 3 amp 4 overlapped 5 amp 6 overlapped 7 amp 8 overlapped Number of displayed channels 8 Number of displayed windows 8 WAVEFORM RECORDING WITH WINDAQ Tach Display Format 7 Display Format 8 D200 Acquisition ME DI 200 Acquisition File Edit View Scaling Options Help File Edit View Scaling Options Help Mode Scroll Channels 0 Mode Scroll Channels 0 A a a EE ror z used Fransara 4 Ya S s F3 10000 ___Compress F7 100 Storage used Frangs s 4 55 2 6929 m i mi ae 3 1482 js i D fest fest Te 2 Volt ae 0 a 2 Volt J Volt 4 Volt 0 i D 3 Volt Ge Volt b Volt Do 0 0 4 Volt Fe Volt a Volt 0 a D Volt 9 Volt A Volt 0 lee ee a E E a D 6 Volt B Volt C Volt oO a 9s Volt D Volt E Volt S Volt F Volt G Volt soon nd H a i Ste se e Scan boul ne DIV 200 0 Status SET UP Waveform Windows 1 2 3 4 5 6 7 amp 8 Waveform Windows 1 amp 2 over
118. r selection bars The colors surrounded by dotted boxes on the selection bars indicate what the palette will look like when the Apply command button is activated Consecutive activation of this button displays all 16 palette selections updating the color selection bars and palette with each activation OK command button Allows you to save a new color combination as one of the 16 display choices When saved the original color combination is overwritten Apply command button Allows you to apply or try out new color combinations without having to save them Also used in conjunction with the Increment Decrement buttons to view the 16 defined palettes For example to see what each palette currently looks like activate the Apply button then the Increment button Repeat this procedure 16 times to see each defined palette Cancel command button Allows you to cancel any color changes made to a palette provided that the changes have not been saved with the OK button When canceled the color scheme will revert back to the original palette you started with Monochrome Displays If you are using WINDAQ Tach with a monochrome monitor select the Monochrome color scheme from the Windows Control Panel Selecting a color scheme other than monochrome may cause display conflicts For example with other color schemes the cursor may seem to disappear when positioned coincident with a dark vertical gridline The same result can happen with a wavef
119. r the amount of screen space devoted to WINDAQ Tach prevents you from seeing them all To display consecutive channels that are higher numbered than the one at the bottom of your monitor Point to the View menu and drag down to Forward Range Y Choose View Forward Range ALT V F For example say you have 32 channels of data enabled for acquisition but for ease of viewing and to keep a high degree of detail you want only 8 displayed at a time on your monitor You can use the Forward Range command to conveniently scroll forward through the remaining channels of data Just select Forward Range from the View menu or use the CTRL DOWN ARROW accelerator keystroke The next higher numbered 8 channels will be displayed Backward Range This function allows you to conveniently scroll through in a backward direction all the consecutive channels you have enabled when they can t be displayed on the monitor all at once This function is most useful when many channels are enabled such as with a slave expansion instrument or with an EXP Series multiplexer and the size of your monitor or the amount of screen space devoted to WINDAQ Tach prevents you from seeing them all To display consecutive channels that are lower numbered than the one at the top of your monitor Point to the View menu and drag down to Backward Range Choose View Backward Range ALT V B For example say you have 32 channels of data enabled for acquisition but for ease
120. re done ACTIVATING PROCEDURE Ensure that the window containing the waveform to be scaled is enabled When enabled the X Y annotation in the left or right annotation margin will be highlighted indicating that window X is enabled for adjustments Although not required the current data and data display options can be enabled for more recognizable results refer to the SCREEN ANNOTATION CONTROL FUNCTION section of this chapter for details on enabling these features To calibrate a waveform using the high low calibration method 1 Select Low Calibration as follows Point to the Edit menu and drag down to Low Calibration Choose Edit Low Calibration ALT E L 98 WAVEFORM RECORDING WITH WINDAQ Tach When selected the Low Calibration dialog box is displayed on the screen Low Calibration EI When the dialog box is first displayed a blinking vertical line called the insertion point appears behind the value in the Low Cal Value text box This insertion point indicates the active area of the dialog box the next action you perform will occur in this area This is where you enter the low calibration data value that is to be assigned to the input voltage level For instance referring back to our previous examples Cancel a For the case where the transducer output is known Input Level Cal Value Engr Units we would enter 0 in the Low Cal Value text box 1 in the Input Level text box and P
121. rential channel and a minus sign is automatically displayed eight channels away 1 e channels 1 and 9 2 and 10 5 and 13 etc indicating the other differential channel You can select the first or positive channel from 1 through 8 but the second or negative channel is automatically selected by the software Clicking the left mouse button on the plus sign removes both plus and minus signs and thus disables the channel pair This configuration is useful anytime you need to monitor the difference between two differential input channels For example say we are monitoring the temperature of a long narrow widget We want the widget to be of uniform temperature throughout its entire length We could use two temperature sensors one per channel on each end of the widget to monitor temperature The temperature of one end of the widget would be measured by one thermocouple and the temperature of the other end of the widget would be measured by the other thermocouple However in the differential channel pair configuration as described above only the difference between the two thermocouples would be reported by WINDAQ software This difference in temperature could then be used to control a process 1 e if one end is 5 hotter than the other then turn on a heater to evenly distribute the widget temperature SPECIAL CONSIDERATIONS Both single ended and differential channels may coexist providing that any one or both of the channels needed to f
122. rmat Screen Next Palette Previous Palette User Palette ToolBox Limits Show Dynamic Range Grow 2X Shrink 2X Invert Waveform Down 1 Pixel Waveform Down 10 Pixels Waveform Up 1 Pixel Waveform Up 10 Pixels Analog Plot Digital Plot Current Data Data Display Limit Display Grids Grid Spacing User Annotation Scroll Mode Oscilloscope Mode Fast Scroll Pause Graphics Beep on File Full Contents Keyboard Mouse Search for Help On How to Use Help About WinDag Acquisition 20 Accelerator key s CTRL Down CTRL Up ALT P ALT SHIFT P CTRL U CTRL T ALT F9 ALT R Up Down CTRL I Gray CTRL Gray Gray CTRL Gray ALT SHIFT N ALT SHIFT T ALT F2 F2 ALT L ALT G Ctrl G ALT U CTRL F1 ALT F1 Reference 4 95 4 75 4 76 4 76 4 50 4 62 4 62 4 63 4 89 4 99 104 4 87 4 109 4 109 4 60 4 110 4 110 4 110 4 110 4 45 4 46 4 83 4 83 4 84 4 86 4 84 4 52 4 52 4 58 4 52 4 39 4 50 WAVEFORM RECORDING WITH WINDAQ Tach WINDAQ Tach OPERATING MODES GENERAL WINDAQ Tach is a special version of WINDAQ Pro software that allows the X axis of WinDaq data acquisition software to be incremented based on distance as opposed to time The software was developed specifically for rail inspection applications where there is a need to precisely locate faults in train rails as part of routine and on going maintenance At this point WINDAQ Tach operates only with model ID
123. s cause WINDAQ Tach display to not advance you can avoid this problem and the above restrictions by putting the WINDAQ Tach data files and CODASPAR BIN in a separate directory which the shortcut that launches it should start in 24 WAVEFORM RECORDING WITH WINDAQ Tach COMMAND REFERENCE GENERAL This is the part of the manual that describes in detail all of the data acquisition commands The following information describes how the information is presented FUNCTION describes what the command is used for and what it will do ACTIVATING PROCEDURE describes the action required to activate the command Whenever applicable the information presented under this heading contains both mouse and keyboard procedures identified by the mouse and keyboard icon in the left margin SPECIAL CONSIDERATIONS describes information beyond activating the command EXAMPLE shows an example of how the command is used 25 WAVEFORM RECORDING WITH WiNDAQ Tach ACQUIRE DATA TO DISK FUNCTION FUNCTION Used to record data to the selected disk drive ACTIVATING PROCEDURE The Record function on the File menu controls data acquisition to disk When first enabled WINDAQ Tach is automatically placed in the SET UP operating mode the status field in the bottom annotation line indicates SET UP This mode allows you to configure the front end instrumentation 1 e sample rate channels gain etc and the real time display so the waveform looks pleasing on your mo
124. s smooth scroll mode When this button is activated the waveform display switches to smooth scroll mode This button does not toggle Either display mode scroll mode or oscilloscope mode may be enabled at any time during data recording without affecting the information being stored to disk This button only affects the way you view waveforms on your monitor This button is the same as choosing Scroll Mode from the Options menu Refer to the Display Mode Selection Function for complete details Oscilloscope Mode Allows you to display waveform information on your monitor in a triggered sweep oscilloscope mode When this button is activated the oscilloscope triggering dialog box is displayed prompting you to choose between a triggered sweep oscilloscope display or a free running oscilloscope display Checking the Free Run check box selects free running oscilloscope display Leaving the Free Run box blank selects triggered sweep oscilloscope display This button does not toggle Either display mode scroll mode or oscilloscope mode may be enabled at any time during data recording without affecting the information being stored to disk This button only affects the way you view waveforms on your monitor This button is the same as choosing Oscilloscope Mode from the Options menu Refer to the Display Mode Selection Function for complete details Triggered Mode Not applicable to WINDAQ Tach software SPECIAL CONSIDERATIONS In terms of end resu
125. s you have selected to the display The display palette changes to reflect your new color choices 5 If you are satisfied with the color scheme you have selected click OK This saves the newly defined color scheme as one of the 16 display palettes overwriting the existing palette If you are not satisfied with the color scheme you can repeat steps 3 and 4 above to get the desired colors or you can click Cancel to get back to the original palette you started with Y 1 Using the techniques described above display the palette you want to change fon 2 Choose View User Palette ALT V U or click the User Palette button in the veers LOI This displays the User Palette dialog box 3 Use the TAB key to move the cursor into the Background Grid Lines and User Annotation Ist Waveform or 2nd Waveform color selection bars Use the lt or cursor control keys to select the colors you want A dotted box appears around the color sample to indicate selection 4 Use the TAB key to highlight the Apply command button A bold box appears around Apply when highlighted 5 To apply the colors you have selected press ENTER The display palette changes to reflect your new color choices 6 If you are satisfied with the color scheme you have selected press the lt cursor control key to highlight the OK command button and press ENTER This saves the newly defined color scheme as one of the 16 display palettes overwriting the existing palette
126. sign a block of any enabled consecutive ADC channels rather than just a single channel To assign a range of channels you must first select the window in which you would like the block of channels to begin This is done by Clicking the left mouse button in the unselected channels annotation margin Typing the number or letter of the display window that contains the waveform to be adjusted The focal point for selecting the desired window is the variable waveform assignment indicator of each channel This is the two element equality X Y displayed for every enabled ADC channel Element X is the waveform window number or letter and element Y is the ADC channel number assigned to that window Element X the waveform window is always the element specified to enable the waveform contained in that window for adjustment When a waveform window is selected a highlighted box surrounds the X Y annotation indicating that the window is enabled for adjustment 1 2 a an DIi 720 Acquisit an DE720 Acquisit m DE720 Acquisit File Edt View File Edit View File Edit View Hode Iriggere Hode Iriggere Hode Triggqere 57s F3 200C S S Esai 0 SS DES 200k 2 5000 3 E a 25000 0879 gt 0879 g 0879 1 0 Medias ii Volt 2 1 0 Volt 2 Lau Unselected Selected window anywhere in window shaded area to select channel When the desired window is selected the channel range can be assigned as follows Point to the Vie
127. small section of waveform This is done by drawing a selection rectangle and then clicking the left mouse button in the annotation margin A selection rectangle is drawn by dragging anywhere in the strip until the area of interest is enclosed in the rectangle When the left 10 Waveform strip WAVEFORM RECORDING WITH WINDAQ Tach mouse button is released the rectangle remains on the display framing the area of interest Now click the left mouse button in the annotation margin to enlarge the contents of the selection rectangle to full strip size Conversely the entire waveform can be shrunk to fit inside a similarly drawn rectangle using the right mouse button Only the left annotation margin is displayed when a non overlapped screen format is selected and both the right and left annotation margins are displayed when an overlapped screen format is selected The information displayed in either margin is identical in format and consists of three parts the variable waveform assignment indicator the numeric value of the waveform at the real time point and the full scale values for the waveform strip When enabled shows a dynamic value of waveform at cursor intersection or 6 static baseline value of window DI 720 Acquisition ioj x File Ecit Jew Sealing Options Help Halea Os0i41 Channels 0 1 2 me S FA CoMmeress FT Full scale values for waveform window 008 Wr lt ie ol ni Gd aka Gee a
128. t X is the waveform window number or letter and element Y is the ADC channel number assigned to that window refer to the VARIABLE WAVEFORM ASSIGNMENTS section of this chapter Element X the waveform window is always the element specified to enable the waveform contained in that window for adjustment When a waveform window is selected a highlighted box surrounds the X Y annotation indicating that the window is enabled for adjustment 2 3 an Di 720 Acquisit an OL 720 Acquisit an DE 720 Acquisit File Edit iew File Edit View File Edit wiew Hode Iriggere Hode Iriggere Hode Iriggqgers 57s Fai 200C S S FS 2000 es Fa 2000 2 S000 7 2 a 7 2 5000 0879 0879 0879 1 0 Wie 110 Volt a 1 0 Volt a UUO Unselected selected window anywhere in window shaded area to select channel When the waveform contained within a specified window is enabled gain adjustments to that channel are now possible To adjust the gain for the enabled channel gt Click the Channel Setup button in the ToolBox Point to the Edit menu and drag down to Channel Settings Choose Edit Channel Settings ALT E G 33 WAVEFORM RECORDING WITH WINDAQ Tach This displays one of the following Channel X Settings dialog boxes where X represents the enabled channel Gain FS Volt FS Yolt Acquisition Method 1 5 0000 5 0000 7 10 50000 50000 Average 100 050000
129. t greater than half that rate To distinguish it from the location values in kilometers displayed by acquisition the word distance in what follows refers to tachometer displacement while storing to disk The acquisition display will always update from left to right or scroll new data in from the right regardless of the direction of the lower right corner of the screen This is the kilometer post location of the tachometer when the number is displayed about 9 times per second If Edit Preferences Update Interval is not zero the graphics and location display will continue while menus and dialog boxes are open The standard WINDAQ Pro options Triggered Mode Triggered Storage Remote Storage and Remote Events will all be disabled with the WINDAQ Tach version of software Appending to a WINDAQ Tach or opening a reference file will set the tachometer calibration to match the file and if it changes the displayed location will change and will need to be readjusted The 32 bit positive file trailer items normally used for time stamps will instead be used for location stamps The low order 30 bits will be a 2 s complement signed number of tachometer pulses with a range of 5368 709110 KM for a tachometer producing one pulse every 10 mm Data bit 30 will be a direction flag with a 1 indicating that the data starting at that file point until the next acquisition start represents decreasing location While recording each time the tachometer reverses a l
130. t line on a dark background for a high signal condition and no line for a low signal condition Multiple combinations are possible SPECIAL CONSIDERATIONS None EXAMPLE None 43 WAVEFORM RECORDING WITH WINDAQ Tach DISPLAY FORMAT SELECTION FUNCTION Used to select a specific waveform display format WINDAQ Tach supports 11 different display formats The particular display format you choose for any given application will be defined by a number of variables but perhaps the most important of these is choosing a format that you feel most comfortable viewing It is important to note that any display format may be enabled at any time during data acquisition without affecting the information stored to disk Display format changes only affect the way you view waveforms on the computer s monitor The choice of a given display format revolves around the distance relationship of your input signals Given two waveforms of interest you may wish to choose an overlapping display format e g format two that will allow you to closely examine their relationship in both the distance and amplitude domains On the other hand a nonoverlapping format such as format three or five may be used to isolate each waveform s transition within a defined area The following chart and the accompanying illustrations provide a graphic example of each display format offered Format Number Window Design Maximum Channels 1 1 window l 2 2 windows overlapped 2 3
131. the DISPLAY FORMAT SELECTION section of this chapter Waveform windows carry a designator number or letter as follows Window Window Window Window Number Designation Number Designation 1 1 17 H 2 2 18 I 3 3 19 J 4 4 20 K 5 5 21 L 6 6 22 M 7 7 23 N 8 8 24 O 9 9 25 P 10 A 26 Q 11 B 27 R 12 C 28 S 13 D 29 T 14 E 30 U 15 F 31 V 16 G 32 W As the above table shows the windows enabled for display are a function of the selected display format By typing the following sequences you can assign any acquired waveform channel number to the specified display window The VARIABLE WAVEFORM ASSIGNMENTS function is best implemented from the keyboard Note that it is possible to use the mouse for this procedure first enable the desired window by clicking in the left right annotation margin then point to the View menu and drag down to Assign Channel and finally type the desired waveform channel number but the keystroke approach is much more streamlined Because of this only the keyboard procedure will be documented here 91 WAVEFORM RECORDING WITH WINDAQ Tach Keystroke Keystroke Keystroke Keystroke One window Two Three channel Four 1 2 not needed 1 1 6 1 1 ENTER 2 1 2 A 3 not needed 4 1 6 4 1 ENTER G 1 4 The above works for any enabled display format and allows you to examine the characteristics of any acquired channel within any display window SPECIAL CONSIDERATIONS When performing any operatio
132. the default voltage or temperature if using thermocouples calibration Acquisition Method The Acquisition Method buttons allow you to select the method used for displaying data on your monitor and storing it on your hard drive All of our hardware products continuously sample data using a burst sampling technique With the burst sampling technique the board or hardware device samples data at one rate referred to as the maximum sampling rate or burst rate while your computer reports 1 e displays and stores this data at another rate called the sample rate or throughput rate Again the burst rate determines how fast the board or hardware device samples your data and the sample rate determines how fast the sampled data is reported Your board or hardware device can sample data much 34 WAVEFORM RECORDING WITH WINDAQ Tach faster than it can report it For example let s say we want to record one channel of data at 100 Hz and our burst rate is set at SOKHz burst rate is modifiable through the Maximum Sample Rate command on the Preferences submenu of the Edit menu and sample rate is modifiable from the Edit menu In this example we are sampling the data at 50kHz and reporting it at 1OOHz This means that for every 500 data points sampled only 1 will be reported The dilemma becomes which data point out of the 500 gets reported Fortunately you have a choice of methods for reporting this single data point Average This method av
133. the dialog box changes to indicate which channel you are currently calibrating 4 Complete the fixed calibration entry as follows Click OK Press the TAB key until a bold border surrounds the OK command button indicating selection and press ENTER 94 WAVEFORM RECORDING WITH WINDAQ Tach The Fixed Calibration dialog box disappears and the waveform channel displays all waveform data values calibrated in the chosen engineering units If desired the upper and lower grid limit values may be specified and the waveform automatically scaled to fit This feature allows the channel s full scale display span to be shown in whole numbers rather than obscure fractional values which sometimes result from calibrating For example a waveform scaled in mmHg can be automatically expanded or contracted to fit within grid limits of O to 100 mmHg or 200 mmHg to 200 mmHg or whatever is desired Note that a channel spanning 0 200 mmHg is much easier to read and interpret on a per division basis than one that spans 10 372 189 628 mmHg To specify convenient upper and lower chart edge values 1 Select Scaling Limits as follows Point to the Scaling menu and drag down to Limits Choose Scaling Limits ALT C L When selected the Display Limits dialog box is displayed on the screen as follows Top Limit 5 0000 Bottom Limit 5 0000 Next Previous Cancel 2 Using the same procedure as before type convenient t
134. the next RECORD mode is activated In this case the comment may be changed or canceled at any time before activating RECORD 52 WAVEFORM RECORDING WITH WINDAQ Tach When the desired comment is entered close the dialog box by Clicking the OK command button Pressing the ENTER key It is possible to preprogram a comment for the automatically generated start acquisition marker While in the SET UP or STBY operating modes choosing Insert Commented Mark immediately causes the Event Marker Comment dialog box to appear prompting you for an event marker comment When entered the comment will be automatically associated with the very next event marker stored to the data file upon transition to the RECORD operating mode SPECIAL CONSIDERATIONS Event markers are saved to disk along with A D data Any event marker comments that were provided ride with the data acquisition file as a trailer refer to the DATA STORAGE FORMAT chapter of the WINDAQ Waveform Browser manual for further information Event markers may be enabled either locally manually by pressing the appropriate accelerator key as in the example below or remotely through a switch closure or TTL signal Refer to the REMOTE CONTROL function of this chapter for details related to remote triggering of event markers An event marker is automatically inserted in the data stream each time the RECORD operating mode is activated An event marker created in this manner is alwa
135. this known quantity per unit of measure instead of using two calibration levels ACTIVATING PROCEDURE Ensure that the window containing the waveform to be calibrated is enabled When enabled the X Y annotation in the left or right annotation margin will be highlighted indicating that window X is enabled for adjustments Although not required the current data and data display options can be enabled for more recognizable results refer to the SCREEN ANNOTATION CONTROL FUNCTION section of this chapter for details on enabling these features To calibrate a waveform using the fixed calibration function 1 Select Fixed Calibration as follows Al Click the Calibration button in the ToolBox Point to the Edit menu and drag down to Fixed Calibration Choose Edit Fixed Calibration ALT E F When selected the Fixed Calibration dialog box is displayed on the screen 93 WAVEFORM RECORDING WITH WINDAQ Tach Channel 1 Fixed Calibration High Calibrator Baseline Full Scale Engr Value 5 0000 Low Calibrator Baseline amp Full Scale Engr Value 5 0000 Next Previous Cancel The values displayed in the Engr Value text boxes are the upper and lower A D converter ranges which are preset according to the selected gain When the dialog box is first displayed a blinking vertical line called the insertion point appears behind the value in the High Calibrator Engr Value text box This insertion point ind
136. tion This lets you bypass the pull down menus and carry out commands directly from the keyboard a time saving feature when processing repetitive tasks Refer to the WINDAQ Tach Acquisition Menu Hierarchy for a listing of accelerators Refer to the WINDAQ Tach Pull Down Menus chart for a roadmap of command locations When you choose a command that is followed by an ellipsis WINDAQ Tach displays a dialog box indicating that more information must be entered or an option must be selected before the command can be carried out Some command names occasionally appear dimmed This indicates that the command does not apply to the current situation or that you may need to make a selection or complete an action before choosing the command The status bar has two purposes to display the current status of acquisition parameters and to provide a fast convenient short cut method for selecting display mode sample rate channels and compression for modification The settings of all current acquisition parameters are shown here Additionally the progress of data storage to disk is shown in the Storage used field and the number of screen updates per second how many times the display is redrawn is shown in the Frames s field Double clicking on the Mode field toggles the operating mode between scroll mode and oscilloscope mode the same as choosing Options Scroll Mode or Options Oscilloscope Mode Double clicking on the S s F3 fiel
137. to examine in greater detail Note that the rectangle remains fixed in size when the left mouse button is released 15 WAVEFORM RECORDING WITH WINDAQ Tach o s Fa 2000 CompreseiF i i Storage 5 used a 3 305 a OSE i i i aiae _ E e CHAH 500 mpr 40 Statue SET UP The scaled waveform accomplished by clicking the left mouse button in the left annotation margin The 3 contents of the selection rectangle have been scaled to fill the entire waveform strip area 16 WAVEFORM RECORDING WITH WINDAQ Tach A TYPICAL DATA ACQUISITION SCREEN USING WinDag Tach OF 720 Acquisition Menu bar Fils Edit Yiew Scaling Optiors Help eS Oscill hannels Ur par Display mode 3s F3 200C empress iF7 1 Storage z used Oooo 2 eee es eS eee Value of waveform at cursor Intersection Variable waveform assignment in dicator Full scale values for Waveform window Lie E sya CAN Status SEI UP M DI 40 S500 Equivalent Distance per grid Current per channel division operating mode sampling rate WAVEFORM RECORDING WITH WINDAQ Tach WinDag Tach Pull Down Menus Ee Edit Open Ctrl O Undo Chile Open Reference File Copy Ctrl C Close Sample Rate ral Save Default Setup Channels F5 Record F4 Channel Settings F10 atop Cher Low Calibration F9 PELER Browse Ala High Calibration F11 Scroll Lirit Freeze erie Fixed Calibration Fie Skip Factor
138. ual allocation of buffer size is generally only needed when the sample rate is displayed in reverse video refer to Appendix A when multitasking with many applications or when you wish to allocate a large input buffer at a low sample rate to accommodate slow computers To specify a buffer size 1 Point to the Edit menu drag down to Preferences and release the left mouse button 2 Inthe Edit Preferences submenu click Buffer Size o Choose Edit Preferences Buffer Size ALT E P B This displays the buffer size dialog box Buffer size needed for gap free data at maximum rate Buffer size in KiloBytes 296 OK Cancel Enter in the text box the desired buffer size When the desired buffer size is entered close the dialog box by D Clicking the OK command button Pressing the ENTER key Beep on Gap Allows you to enable disable a short audible beep that sounds when the system is too busy to store gap free data To enable the audible beep if disabled or disable it 1f enabled D 1 Point to the Edit menu drag down to Preferences and release the left mouse button 2 Inthe Edit Preferences submenu click Beep on Gap Y Choose Edit Preferences Beep on Gap ALT E P G When the beep on gap option is enabled a check mark V is displayed on the Edit Preferences submenu immediately preceding the Beep on Gap command 67 WAVEFORM RECORDING WITH WINDAQ Tach Frame Rate Allows you to enable disa
139. ur conditions As a starting point select a compression factor that delivers the most pleasing waveform display Refer to Appendix A for more information about how compression affects multitasking A fast and convenient way to experiment with many different compression factors is with the Compression x2 and Compression 2 commands These commands respectively multiply or divide the current compression factor by 2 To multiply the current compression factor by 2 Point to the Edit menu and drag down to Compression x2 Choose Edit Compression x2 ALT E S Similarly to divide the current compression factor by 2 Point to the Edit menu and drag down to Compression 2 Choose Edit Compression 2 ALT E E Perhaps these two functions are most useful when the accelerator keys PGUP for Compression x2 and PGDN for Compression 2 are used This allows you to press one key several times in succession to find just the right amount of compression for a smooth scrolling visually pleasing display SPECIAL CONSIDERATIONS A compression factor represents the number of waveform values for each enabled channel that are evaluated for minimum and maximum line segment end points before plotting For example if the compression factor is set to 100 one vertical line is plotted every 100 acquired data points for each channel Waveform compression affects the real time waveform display only Data streamed to disk is unaffected and is always stored at a compr
140. w menu and drag down to Assign Range Choose View Assign Range ALT V R ne WAVEFORM RECORDING WITH WINDAQ Tach This causes the channel number element Y in the highlighted box surrounding the X Y annotation to blink Enter the new or desired channel number here If the box is still blinking after typing fewer than the maximum number of digits press a non numeric key to stop it from blinking Display windows appearing on the monitor below the selected one are now assigned consecutively higher numbered channels while the display windows appearing on the monitor above the selected one are now assigned consecutively lower numbered channels For example say you have 16 channels of data enabled for acquisition but for some reason can only display 8 at a time on your monitor You can use the Assign Range command to conveniently see the remaining eight channels of data Just select waveform window 1 select Assign Range from the View menu and enter 8 in the blinking box Instead of channels 0 through 7 waveform windows through 8 now show channels 8 through 15 Forward Range This function allows you to conveniently scroll through in a forward direction all the consecutive channels you have enabled when they can t be displayed on the monitor all at once This function is most useful when many channels are enabled such as with a slave expansion instrument or with an EXP Series multiplexer and the size of your monitor o
141. ximum values for your particular hardware When the desired maximum sample rate is entered close the dialog box by DO Clicking the OK command button Pressing the ENTER key The following diagram illustrates the relationship of maximum burst rate to sample rate 75 WAVEFORM RECORDING WITH WINDAQ Tach 0137 900 A A sample rate 012 800 A A sample rate 01 700 A A sample rate 009 600 A A sample rate 007 500 A A sample rate 500 600 700 800 900 80 000 Maximum burst rate es by selecting Maximum Sample Rate rom the Preferences submenu on the Eddtmenu As can be seen from the illustration the maximum burst rate must be set to the low end of its range to get a sample rate less than 1 The maximum burst rate can be restored to its previous value if desired The Input Buffer Size in KiloBytes value is displayed for informational purposes only in this text box it can not be directly adjusted by the user It indicates the size of the input buffer which is where the acquired data will be temporarily stored in valuable or scarce contiguous Global DOS memory The amount of memory allocated for this buffer is a function of three factors the current sample rate how much memory is currently being used by your computer and the input buffer size limit maximum amount of your computer s memory you have dedicated to this buffer specified from the Preferences c
142. y affects how the display looks on your screen Data acquired to disk is independent of this function Valid scroll limit entries range from 0 to 32 767 The default limit is 0 In most cases the scroll limit should be set to zero and left there At a scroll limit of 0 no discontinuity will exist In other cases where special hardware has been installed in your computer to accelerate display performance the scroll limit should be maximized to take advantage of your display adapters enhanced capability In the rest of the cases the scroll limit can be experimented with to provide the best looking display If you have a computer with a slower processor and a standard VGA display adapter or less the scroll limit should be set to 0 On this type of personal computer there is nothing to gain by increasing the scroll limit If you wish to enhance the appearance or performance of your display try other methods such as increasing compression decreasing the window size decreasing the sample rate or selecting the Fast Scroll option from the Options menu If you have a computer equipped with a co processor based display adapter that is capable of scrolling such as the IBM 8514 PS2 any XGA controller or any Windows graphics accelerator the scroll limit should be set to 32 767 On this type of personal computer the display discontinuity can be eliminated or minimized and the display performance can be optimized by maximizing the scroll limit If
143. you are essentially plotting less often resulting in a slower real time display which smooths the display and allows you to see the characteristics of the waveform making it more visually pleasing When compression is selected a true min max is performed on the waveform to ensure that transient information is always displayed ACTIVATING PROCEDURE The degree of waveform compression is controlled as follows lI ote Click the Waveform Compression button in the ToolBox O Point to the Edit menu and drag down to Compression OR Double click on the Compress F7 field in the status bar Choose Edit Compression ALT E R This displays the Compression dialog box as follows 102 WAVEFORM RECORDING WITH WINDAQ Tach Compression Desired Compression To OK Cancel When the Compression dialog box is first displayed a blinking vertical line called the insertion point appears behind the number in the Desired Compression text box This insertion point indicates the active area of the dialog box the next action you perform will occur in this area To specify a degree of waveform compression D Enter the desired compression factor from 1 to 65 536 and click OK Enter the desired compression factor from 1 to 65 536 and press ENTER The amount of compression you choose will depend on many factors and will probably include some trial and error to arrive at the compression factor that satisfies all of yo
144. ys tagged with a time and date stamp that allows any point in a recorded waveform file to be correlated with a precise date and time of occurrence to the nearest second Refer to the SEARCH FOR EVENT function of the WINDAQ Waveform Browser user s manual for further information related to viewing and using time and date stamp information WINDAQ Tach allocates 4 bytes of Global DOS memory per entry for event marker time and date stamp and comment information as follows Event marker without time and date stamp or comment entry Event marker with time and date stamp only 2 entries Event marker with comment only 2 entries Event marker with time and date stamp and comment 3 entries Each character of a comment occupies 1 byte of extended memory The total number of bytes required for one comment is equal to the total number of characters in the comment 39 maximum plus one character Cie ee The total number of entries per manual start for items 1 through 4 above is configurable by Edit Preferences Event Mark Capacity These numbers may be used as follows to calculate the total number of event markers of any type that may be used per manual start Divide the capacity less 2 by the number of entries required for each event marker operation For example with the maximum configuration of 16 384 entries if all event markers enabled by you during data acquisition are without comments then a total of 16 382 may be activated between an unc