Home

User Manual PDF - CompSource.com

image

Contents

1. 4 000 7 200 8 400 9 600 12 000 14 400 16 800 18 000 19 200 28 800 32 000 38 400 48 000 56 000 and 64 000 bps 1 200 bps synchronous not supported at 56 000 bps and 64 000 bps composite line rate DIAL BACKUP MODULE SPECIFICATIONS ISDN BRI Module Application Full duplex data transmission via ISDN BRI U Interface for point to point or multipoint facilities Integrated NT1 included Modulation and Frequency 2B1Q line coding with 4 level pulse amplitude modulation PAM at 80K baud Channel Equalization Receiver Automatic adaptive equalizer with echo cancellation Communication Line 2 wire BRI ISDN line Data Rates 56 and 64 Kbps Note that ISDN DBM or DBM I use proprietary rate adaption to support data rates of less than 64 Kbps DBM Interface Compatible with 3600 Series 2 wire and 4 wire Switched 56 DBMs Receive Interface Dynamic Range Operates on 2 wire loops as defined an ANSI T1 601 1992 Impedance 135 Ohms Switched Network Interface 3610 DSU 8 pin non keyed modular jack USOC SJ A11 U Interface Connector 3611 DSU One or two 50 pin connector pinout same as RJ 21X Transmit Interface Signal Level 13 5 dBm nominal over frequency band from 0 Hz to 80K Hz Impedance 135 Ohms Asynchronous Character Format 6 7 8 9 or 10 bits 1 or 2 stop bits Elastic Storage Buffers 5 bits per second Timing DDS intemal all ports external provided by selected port Digital Sharing Device
2. DSD Two groups up to six ports Contention RTS or ungovemed V 32bis Module Analog Dial Module Full or half duplex data transmission via analog 2 wire DDD Communications Line 2 wire PSTN line Data Rate Synchronous or asynchronous terminal rates of 2 400 4 800 9 600 12 000 and 14 400 bps PSTN Network Interface 3610 Standalone 8 pin modular jack Permissive USOC RJ 11C Programmable USOC RJ 45S 3611 Carrier Card 50 pin connector one for slots 1 8 one for slots 9 16 Permissive USOC RJ 21X Programmable USOC RJ 27X SW56 Modules Digital Dial Module DM Full or half duplex data transmission via 4 wire Switched 56 Kbps or 2 wire Switched 56 Kbps point to point Communications Line 4 wire Switched 56 Kbps AT amp T ACCUNET AT amp T SDDN and U S Sprint VPN56 2 wire Switched 56 Kbps DataPath Compatible Data Rate Synchronous or asynchronous terminal rate of 56 000 bps 4 Wire Switched 56 Kbps Network Interface 3610 Standalone 8 pin modular jack USOC SJ A56 3611 Carrier Card 50 pin connector USOC SJ A57 one for slots 1 8 one for slots 9 16 2 Wire Switched 56 Kbps Network Interface 3610 Standalone SJ A48 6 pin modular jack 3611 Carrier Card 50 pin connector Pinout same as RJ 21X KANADAI S 3610 back panel 3610 with TDM back panel DIAL BACKUP MODULE DBM OPTIONS The Dial Restoral option offers complete flexibility in all areas of user application recovery Dial Restoral provides autom
3. plus SDU and fan module 563 BTU hr max Dimensions 3610 Standalone Height 2 13 inches 5 4 cm Width 7 63 inches 19 4 cm Depth 13 4 inches 34 0 cm 3611 Carrier Card Height 7 13 inches 18 1 cm Width 0 9 inches 2 3 cm Depth 13 4 inches 34 0 cm 3000 Series Carrer Height 10 5 inches 26 7 cm Width 19 0 inches 48 3 cm Depth 14 0 inches 35 6 cm Weight 3610 Standalone 5 Ib 2 3Kg 3611 Carrier Card 1 5 Ib 0 7Kg 3000 Series Carrier 16 DSUs plus SDU and fan 70 Ibs 31 8 Kg Regulatory Approvals FCC Part 15 Class A digital device FCC Part 68 AW292 61661 DD N 3610 Standalone Listed UL 1950 Certified CSA C22 2 No 220 M 1986 3611 Carrier Card 3000 Series Carrier Recognized Component UL 1950 CSA Safety Certified CSA 22 2 No 950 M 89 3610 and 3611 CSA Emissions Class A digital apparatus Bell Canada DCTE Specifications J uly 1989 Issue 1 KANADAN S TDM MCMP MULTICHANNEL MULTIPOINT MCM P FUNCTION THAT ALLOWS UP TO SIX NON DISRUPTIVE PROTOCOL INDEPENDENT DATA PATHS OVER A SINGLE MULTIPOINT CIRCUIT STANDALONE ONLY VERSION HAS FLEX MUX FUNCTION 2 OR 6 PORTS 10R5 PORTS DB25 IN THE EXPANDED HOUSING CONFIGURED AS EITHER ELECTRICAL EIA 232 OR V 35 AND 1 PORT ON THE BASE DSU AS EITHER EIA 232D OR V 35 CONNECTOR OPERATIONAL MODES OF MCMP TDM DSD AND MULTIPOINT DIAL RESTORAL BRIDGE ONE OR TWO PORT SHARING GROUPS THAT PROVIDE UP TO
4. 3610 SERIES e FULLY INTEGRATED NETWORK MANAGE MENT CAPABILITIES FOR COM PREHENSIVE TESTING MONITORING AND CONTROL e ASCII TERMINAL INTERFACE ALLOWS AN ASCII TERMINAL FULL DIAGNOSTIC AND CONFIGURATION CONTROL OF STANDALONE VERSIONS ONLY e NETVIEW LPDA 2 MANAGEMENT e POINT TO POINT AND MULTIPOINT NON DISRUPTIVE DIAGNOSTICS e DDS RATES FROM 2 4 TO 64 Kbps e _USER CONFIGURABLE DATA RATES FROM 150 TO 56 000 bps AND 64 000 bps CLEAR CHANNEL e RATE ADAPTATION FOR POINT TO POINT AND MULTIPOINT CIRCUITS e AVAILABLE IN STANDALONE AND CARRIER CARD VERSIONS e CO RESIDENT EIA 232D V 24 AND CCITT V 35 INTERFACES continued on page 2 C SPHERE 3610 Seres Data Service Units DSUs are highly reliable state of the art products ideal for today s network managed digital environments The COM SPHERE 3610 DSU enables users to take maximum advantage of today s digital services Operating in conjunction with Paradyne s COMSPHERE 6700 Series Network Management System NMS the COMSPHERE 3610 Series DSU provides a comprehensive network management solution that is both flexible and affordable Network management options are expanded to include SNMP when used with the COMSPHERE 6700 and optional SNMP agent software The series uses an advanced diagnostic technique to provide comprehensive network monitoring testing and control over point to point and multipoint circuits Network managers are provided with a compr
5. 6 PORTS AUTOMATIC TDM RECONFIGURATION TO A REDUCED DATA RATE UPON ENTRY INTO DIAL RESTORAL MODE INDIVIDUAL PORT TESTS AND LOOPBACKS ELASTIC STORE FEATURE PROVIDES A BUFFER ON EACH PORT TO SUPPORT DIGITAL OR ANALOG EXTENDED CIRCUITS DIGITAL BRIDGE FOR MULTIPOINT DIAL RESTORAL CONCURRENT OPERATION OF TDM AND DSD MODES OPTIONAL FEATURES TIME DIVISION MULTIPLEXER TDM MULTICHANNEL MULTIPOINT MCMP OPTION Increased flexibility in network design and implementation is an important advantage of the Time Division Multiplexer Digital Sharing Device TDM DSD Flex option while providing cost effective data networking altematives The TDM DSD Flex function improves the use of digital facilities through bandwidth control and allocation The TDM DSD Flex option can be controlled by the 6700 Series NMS the Shared Diagnostic Control Panel SDCP or the COM SPHERE 3610 front panel TDM The TDM will multiplex up to six channels onto a single point to point digital facility Configured as a DSD the DSU allows up to six polled protocol devices to share a single point to point or multi point digital facility Configured as a host port sharing device the TDM DSD Flex shares up to six host ports for the primary purpose of disaster recovery Three ports are used for the primary data path and three ports for automatic hot spare during a front end port failure The versatile TDM DSD Flex option when configured with the Dial
6. Backup M odule DBM card version serves as the digital bridge for multipoint single call dial restoral applications The TDM DSD Flex option requires an expanded housing to the COMSPHERE 3610 standalone version and a separate card slot in the COMSPHERE 3000 Series Carrier with the COMSPHERE 3611 card version MCMP The MultiChannel MultiPoint MCMP option builds on TDM DSD features by supporting all TDM DSD functions while adding MCMP functions to create one of the most powerful and flexible DSUs in the industry The sophisticated M CMP option uses a patented technology to consolidate multiple applications and protocols over a single multipoint digital facility Up to six individual data channels can be configured for your multipoint circuit Each channel is non interfering with other channels and protocol insensitive These characteristics broaden the number of applications available to allow both point to point and multipoint applications to work on the same mulitpoint circuit MCMP comes in both a two and six port standalone version that can be mixed on the same circuit This means you do not have to buy a six port version for all remote sites when all you need is atwo port version at some sites and a six port version at other sites The unique any port to any port mapping feature from the central site DSU to remote DSUs adds flexibility to your configuration choices This unique mapping feature allows remote site configurations to support bot
7. MSPHERE 3000 Canier Options Fan Module 115 VAC 3000 F1 007 Shared Diagnostic Control Panel 3000 F 1 001 with ribbon cable Shared Diagnostic Unit SDU 3000 F 1 002 Rear Connector Plate 3000 F 1 021 Filler Panel 3000 F 1 008 NMS EIA 232 Interface Connector 6821 F 1 513 Remote site Adapter Cables 6821 F1 518 M6AYand M6BK 7 and 5 respectively Network Adapter Cable 1 5 3600 F2 503 50 pin to eight 8 pin Modular 3600 F2 503 Network Interfaces DSU M8 lease Adapter for Digital or Leased Lines ASCII Interface Cable 10 3600 F3 504 DSU Control Channel RJ 11 to DB25 DTE connector S A DSU with 2 port TDM MCMP Flex 3610 A4 020 S A DSU with 6 port TDM MCMP Flex 3610 A4 024 Nest DSU with 6 port TDM M CMP 3611 B4 003 V 35 Interconnect Cable for card 3600 F3 500 version only Description Model Number Field upgrade options to existing DSUs S A DSU upgrade to 2 port 3600 F3 209 TDM MCMP Flex Field Install S A DSU upgrade to 6 port 3600 F3 213 TDM MCMP Flex Field Install NEST DSU upgrade to 6 port 3600 F4 205 TDM MCMP Field Install Cables V 35 Interconnect Cable for 3600 F 3 500 card version only 18 DSUs with integrated dial restoral modules S A R3 DSU w ISDN BRI DBU 3610 A4 026 Nest R3 DSU w ISDN BRI DBU 3611 B4 026 S A R3 DSU w 14 4 Kbps 3610 A4 002 analog DBU Nest R3 DSU w 14 4 Kbps 3611 B4 002 analog DBU Standalone R3 DSU 3610 A4 014 w 4W SW56 DBU Nest R3 DSU w 4W SW56 DBU 3611 B4 014
8. Standalone R3 DSU 3610 A4 012 w 2W SW56 DBU Nest R3 DSU w 2W SW56 DBU 3611 B4 012 Card version dial restoral modules for multipoint circuits for use with TDM card version optioned as digital bridge ISDN BRI DBM4 M P Dial Restoral 3611 B4 016 14 4 Kbps analog DBM V 3611 B4 005 M P Dial Restoral 4W SW56 DBM S M P Dial Restoral 3611 B4 008 2W SW56 DBM D MP Dial Restoral 3611 B4 010 Description Model Number Field upgrade options to existing DSUs ISDN BRI Dial Restoral Field Install 3600 F 3 026 14 4 Kbps analog Dial 3600 F3 201 Restoral Field Install 4W SW56 Dial Restoral Field Install 3600 F 3 056 2W SW56 Dial Restoral Field Install 3600 F 3 256 Network Interface Module NIM for use with COMSPHERE 3000 Canier and 3611 card version DSU Permissive for ISDN BRI 14 4 Kbps 3000 F1 003 and 2 wire SW56 Kbps 1 per 8 carier slots Programmable for 14 4 Kbps 3000 F 1 004 1 per 8 carier slots For 4 wire SW56 Kbps 3000 F1 025 1 per 8 carier slots 50 pin mass termination cable 1 per NIM Permissive RJ 21X Programmable RJ 27X Telephone Cables for use with Standalone COMSPHERE 3610 Series DSU 3610 Series DSU Modular 7 4400 F 1 531 RJ 11C 6 pin Permissive 14 3600 F3 503 DDD PSTN plug 25 4400 F 1 533 10 3000 F1 013 30 3000 F 1 014 Modular RJ 45S 8 pin 7 4400 F1 541 Programmable DDD 14 4400 F 1 543 PSTN plug 25 4400 F1 544 Telephone Cords for use with Standalone COMSPHERE 3610 S
9. ated single call point to point and multipoint restoral over either the ISDN BRI network the two wire Public Switched Telephone Network PSTN two wire Switched 56 Digital Network or fourwire Switched 56 Digital Network Point to point restoral is accomplished using an integral Dial Backup Module DBM Dial line rates supported for the ISDN BRI connection include full duplex 56 000 or 64 000 bps operation Dial line rates supported for the PSTN connection include full duplex 14 400 bps 12 000 bps 9 600 bps 4 800 bps or 2 400 bps operation The dial restoral connection can be controlled by the COMSPHERE 6700 Series NMS the Shared Diagnostic Control Panel SDCP or the COMSPHERE 3610 front panel While in dial restoral mode the DSU automatically looks back to the digital facility and evaluates its health switching back as soon as service is restored This automatic lookback feature helps minimize line costs by eliminating extended long distance line charges once the digital facility becomes operational again Networks requiring contin uous availability can now attain uptime goals without dedicated around the clock staffing at the network control center An automated dial tone test during non usage periods informs network operations if the dial restoral circuit is disconnected This eliminates the requirement for expensive and time consuming manual testing of dial restoral circuits by network operations In addition to its automatic restoral
10. capabilities the versatile Dial Restoral Option features password and call back security When enabled these security options prevent unauthorized access and ensure integrity of the digital facility A 10 number directory is capable of selecting altemative destinations for the automated dial restoral process as well as callback numbers for security Multipoint dial restoral is easy using the digital bridge feature of the card version TDM MCMP option and the DBMs both of which are housed in the COMSPHERE 3000 Series Carrier Each digital bridge provides bridging for five remotes Additional bridges can be interconnected to the first or primary bridge up to a maximum of six including the primary bridge to back up a total of 25 remotes The COM SPHERE 6700 Series NMS maintains complete control of the network during the multipoint restoral process DIAL BACKUP MODULE WIDE SELECTION OF AUTOMATIC DIAL RESTORAL OPTIONS WITH ISDN BRI 1B D ANALOG V 32bis 14 4 Kbps OR 2 OR 4 WIRE SW56 UNIQUE DIAL TONE MONITORING TO ENSURE AVAILABILITY OF RESTORAL CIRCUIT AUTOMATIC RETURN TO DIGITAL LEASED LINE AFTER RESUMING NORMAL SERVICE KANADAI S CONTROLS AND INDICATORS The COMSPHERE 3610 Diagnostic Control Panel DCP 3611 face plate and the optional SDCP feature a full complement of controls and indica tors They incorporate a menu driven English language display to monitor on line performance change operating modes and cont
11. ehensive feature set and options that combine to maximize network availability reduce equipment costs and provide fully integrated network management control The COMSPHERE 3610 also provides an SNA Diagnostic Interface for enhanced NetView LPDA 2 interoperability Low cost device control is provided via an ASCII terminal using the COMSPHERE 3610 ASCII support feature This feature is available only in the standalone version KANADAN S Sunen FEATURES 3610 SERIES continued from page 1 e AUTO RATE DETECTION e CROSS PAIR DETECTION e EXTENDED RANGE SUPPORT e POINT TO POINT OR MULTIPOINT OPERATION e STANDALONE VERSION FEATURES A USER FRIENDLY FRONT PANEL WITH A TWO LINE 16 CHARACTER PER LINE MENU DRIVEN DISPLAY WITH KEYPAD FOR CONTROL OF LOCAL AND REMOTE DEVICES e FULL COMPLEMENT OF LOCAL AND REMOTE LOOPBACKS e INTEGRAL 511 TEST PATTERN GENERATOR AND COMPARATOR e THREE POWER LEVELS FOR COMPATIBILITY WITH RBOC AND LOCAL EXCHANGE CARRIER FIXED DATA RATES OF 19 200 bps e ELASTIC STORE FEATURE FOR EXTENDED CIRCUIT APPLICATIONS e POINT TO POINT OPERATION AS A LIMITED DISTANCE MODEM e ASYNCHRONOUS OR SYNCHRONOUS SUPPORT ON ALL PORTS 3610 SERIES SPECIFICATIONS DSU Module Digital data services provided by Regional Bell Operating Companies RBOCs and Local Exchange Carriers LECs Data Rate Synchronous terminal rates of 2 400 4 800 9 600 19 200 56 000 and 64 000 bps Elastic St
12. eries DSU Modular RJ 11C 6 pin 14 3600 F3 503 for 2 wire SW56 Kbps Modular RJ 45S 8 pin 14 3600 F3 501 for 4 wire SW56 Kbps 25 3600 F3 502 For additional information on this or any Paradyne product or service contact the office nearest you Or dial toll free USA and Canada 800 482 3333 or call 813 530 8623 Fax USA 813 530 2103 Toronto 905 709 5000 fax 905 709 3469 Montreal 514 288 0001 fax 514 288 1246 Europe 44 1 753 515000 fax 44 1 753 550011 J apan 81 3 5541 6630 fax 81 3 5541 6631 Hong Kong 852 2543 0083 fax 852 2541 3767 Latin America 813 530 8358 fax 813 532 5240 Singapore 65 355 5230 fax 65 355 5244 Intemet address http www paradyne com Specifications subject to change without notice Printed in U S A Paradyne Corporation 1997 COMSPHERE is a registered trademark of Paradyne Corporation PARADYNE and ANALYSIS are trademarks of Paradyne Corporation All other products or services mentioned are the trademarks service marks registered trademarks or registered ser vice marks of their respective owners 50 TOTAL RECOVERED FIBER 10 POST CONSUMER FIBER DIG DS36 2 0197 KANADAI S
13. h MCMP and DSD applications As with the TDM DSD option up to two DSD groups can be configured or use the digital bridge mode for multipoint single call dial restoral applications continued on page 4 KANADAN S MCM P continued from page 3 The TDM MCMP option is supported by both the COMSPHERE 3610 standalone version and the COMSPHERE 3611 card version The stand alone version provides Flex function which allows each port to be configured as either RS232 or V 35 electrical An expanded housing which provides either one or five standard DB25 connectors is required for either two or six port TDM M CMP respectively When V 35 electrical is selected a DB25 to V 35 conversion cable is required for ports two through six No conversion cable is required for port one because it is assigned to either an RS232D or V 35 connector on the base DSU unit The card version supports two or six port TDM M CMP with port one as either RS232D or V 35 connector and ports two through six as RS232 A DB26 to V 35 connector cable is required when port one is assigned as a V 35 connection Two card slots are required to support TDM MCMP in the COMSPHERE 3000 Series Carrier Thus allowing a maximum of eight M CMP DSUs per carier TDM MCMP SPECIFICATIONS Composite Speeds TDM 2 400 4 800 9 600 19 200 38 400 56 000 and 64 000 bps MCMP 56 000 bps 48 000 usable for data Port Speeds Synchronous terminal rates of 1 200 2 000 2 400
14. orage Buffer 8 bits Timing DDS intemal extemal or receiver Data Format Serial synchronous protocol independent binary data in full or half duplex operation Data Encoding Bipolar retum to zero complies with AT amp T Technical Reference 62310 1987 Transmit Levels 19 200 bps 10 0 or 6 dBm 9 600 bps 0 dBm All other speeds 6 dBm Receiver Sensitivity Level 42 dBm at 56 000 bps Transmit and Receive Impedances 135 ohms nominal Digital Network Interface 3610 Standalone 8 pin modular jack USOC RJ 48S 3611 Carrier Card 50 pin connector USOC RJ 48T one for slots 1 8 one for slots 9 16 Network Management System Compatibility COMSPHERE 6700 6800 Series NMS Device control via ASCII interface Standalone only DTE Interface 25 pin subminiature connector female EIA 232D CCITT V 24 ISO 2110 34 pin connector female CCITT V 35 ISO 2593 AC Power Requirements 3610 Standalone 90 132 VAC 60 Hz 3Hz 0 15 amp 13 4 watts max at 115 VAC 3611 Carrier Card Supplied by carrier 80 watts max 3000 Series Carrier fan module Supplied by carrier 45 watts Environment Operating temperature 32 F 0 C to 122 F 50 C Storage temperature 4 F 20 C to 158 F 70 C Relative humidity 5 to 90 non condensing Shock and vibration withstands normal shipping and handling Heat Dissipation at 115 VAC 3610 Standalone 32 4 BTU hr max 3000 Series Carrier 16 DSUs
15. rol local and remote testing Indicators These display signal activity at the DTE DSU interface and provide operational status information Alpha Numeric Display The two line by 16 character LCD on the front panel displays status information and serves as the primary user interface for equipment setup reconfiguration and diagnostic operation ORDERING INFORMATION Controls Function keys F1 F2 etc are used to select options and move within the menu structure for equipment configuration testing and similar operations Basic DSU Indicators TXD 103 Transmit data RXD 104 Receive data RTS 105 Request to send CTS 106 Clear to send DSR 107 Data set ready DTR 108 Data terminal ready LSD 109 Line signal detect DSU Status Indicators OK Normal operation Alarm Fault in DSU DBM or facility streaming DTE Test Test in progress Dial DBM active Front Panel Indicates card selected by SDCP 3611 only SDCP Controls and Indicators Select Provides SDCP selection of carrier DSU Bck Up Indicates selected DSU in dial backup mode DCP Controls A Moves up one menu level lt 1 Moves one position to left on menu A Moves to top of menu D Moves one position to right on menu F1 F2 F3 Multifunction keys defined by display line located above them Description Model Number Standalone DSU 3610 A4 001 Nest DSU 3611 B4 001 COM SPHERE 3000 Carrier with 115 VAC Power 3000 B1 201 CO

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SyncMaster  MEMORACK 180 - ADB Lighting Technologies  ZTE Kis3 max Mobile Phone Quick Start Guide  Oster 3263 Coffeemaker User Manual  機械工事共通仕様書    ユーザー取り扱い説明書  Océ VarioPrint® 4110/4120 - Océ  Technical Service Bulletin  LN™- 25 PIPE - Lincoln Electric  

Copyright © All rights reserved.
Failed to retrieve file