Home
Cut Sheet
Contents
1. 11 04 555 8 21 88 219 8 8 65 200 0 7 87 491 0 19 33 6 9 0 27 18 60 41 0 Flange Mount A 156 0 6 14 225 8 8 89 178 6 7 03 123 0 4 84 55 6 2 19 2 71 6 0 B 205 2 8 08 234 6 9 24 178 6 7 03 123 0 4 84 55 6 2 19 3 60 7 9 C 219 0 8 62 300 0 11 81 178 6 7 03 123 0 4 84 55 6 2 19 6 89 15 2 D 248 4 9 78 350 0 13 78 178 6 7 03 123 0 4 84 55 6 2 19 9 25 20 4 E 280 3 11 04 555 8 21 88 207 1 8 15 117 2 4 61 89 9 3 54 18 60 41 0 1 Weights include HIM and standard 1 0 Rockwell Automation Publication 20A TD001J EN P July 2014 29 Table 18 Specifications Category Protection Environment PowerFlex 70 Adjustable Frequency AC Drive Specification Drive 200 240V 380 400 480V 600V 690V 208V AC input overvoltage trip 247V AC 285V AC 475V AC 570V AC 690V AC AC input undervoltage trip 120V AC 138V AC 233V AC 280V AC 345V AC Bus overvoltage trip 405VDC 405VDC 810VDC 810V DC 1013V DC Bus undervoltage output shutoff 153V DC 153VDC 305VDC 437VDC 437V DC Bus undervoltage fault level 160V DC 160VDC 300VDC 300V DC 375V DC Nominal bus voltage 281V DC 324VDC 540VDC 648V DC 810V DC All Drives Heat sink thermistor Monitored by microprocessor overtemp trip Drive overcurrent trip Software current limit Hardware current limit Instantaneou
2. for the drives Figure 1 Frames A E 1P20 66 NEMA UL Type 1 4X 12 Flange Mount k 4 F C gt x A gt j c gt ae I gt o o A _AT l a ri ri Oh MN E il Oh B B WI MUON YP m ee a O fd o T x 7 F o E k Table 14 Frame Dimensions mm in Frame Size Dimension Weight A B c D E F kg Ib IP20 NEMA UL Type 1 A 122 4 4 82 225 7 8 89 179 8 7 08 94 2 3 71 211 6 8 33 5 8 0 23 2 71 6 0 B 171 7 6 76 234 6 9 24 179 8 7 08 122 7 4 83 220 2 8 67 5 8 0 23 3 60 7 9 C 185 0 7 28 300 0 11 81 179 8 7 08 137 6 5 42 285 6 11 25 5 8 0 23 6 89 15 2 D 219 9 8 66 350 0 13 78 179 8 7 08 169 0 6 65 335 6 13 21 58 0 23 9 25 20 4 E 280 3 11 04 555 8 21 88 207 1 8 15 200 0 7 87 491 0 19 33 6 9 0 27 18 60 41 0 IP66 NEMA UL Type 4X 12 B 171 7 6 76 239 8 9 44 203 3 8 00 122 7 4 83 220 2 8 67 5 8 0 23 3 61 8 0 D 219 9 8 66 350 0 13 78 210 7 8 29 169 0 6 65 335 6 13 21 5 8 0 23 9 13 20 1 E 280 3
3. 0 60 30 40 E 041 41 30 40 E 072 72 37 50 E 052 52 37 50 E CE certification testing has not been performed on 600V class drives c4 ND Rating 480V 60 Hz Input d Code Amps kW Hp Frame Enclosure 1P1 1 1 0 37 0 5 A Code Enclosure OPI 21 0 75 1 0 A A Panel Mount IP 20 NEMA UL 3P4 3 4 1 5 2 0 A Type i Wall Machine Mount IP66 5P0 5 0 2 2 3 0 B NEMA UL Type 4X 12 for 8PO 8 0 3 7 5 0 B indoor use only 011 11 5 5 7 5 Cc Flange Mount Front Chassis 014 14 7 5 10 IP 20 NEMA UL Type 1 Rear owe e fuo o o E 027 27 15 20 D use 034 34 18 5 25 D G Wall Machine Mount IP54 040 40 22 30 D NEMA UL Type 12 052 52 30 40 E x Only available on Frame E 065 65 37 50 E e HIM Code Interface Module 0 Blank Cover 3 Full Numeric LCD 5 Prog Only LCD 1 3 4 5 7 20A B 2P2 A a b c d a Drive Code Type 20A PowerFlex 70 b Voltage Rating Code Voltage Ph B 240V AC 3 Cc 400V AC 3 D 480V AC 3 E 600V AC 3 cl ND Rating 208V 60 Hz Input Code Amps kW Hp Frame 2P2 2 5 0 37 0 5 A 4P2 4 8 0 75 1 0 A 6P8 7 8 1 5 2 0 B 9P6 11 2 2 3 0 B 015 17 5 4 0 5 0 Cc 022 25 3 5 5 7 5 D 028 32 2 7 5 10 D 042 43 11 15 D 054 62 1 15 20 E 070 78 2 18 5 25 E c2 ND Rating 240V 60 Hz Input Code Amps kW Hp Frame 2P2 2 2 0 37 0 5 A 4P2 4 2 0 75 1 0 A 6P8 6 8 1 5 2 0 B 9P6 9 6 2 2 3 0 B 015 15 3 4 0 5 0 Cc 022 22 5 5 7 5 D 028 28 7 5 10 D 042 42 11 15 D 054 54 15
4. 20 E 070 70 18 5 25 E Only available with NEMA 4X option C See Catalog Number Explanation continued on page 6 for more drive options Rockwell Automation Publication 20A TDOO1J EN P July 2014 PowerFlex 70 Adjustable Frequency AC Drive Catalog Number Explanation continued 1 3 4 5 7 8 a b C d f Documentation Code Type A Manual N No Manual g Brake IGBT Code w Brake IGBT NE Yes h Internal Brake Resistor Code w Resistor v Yes N No Position Number 9 10 11 12 13 14 15 16 e f g h i j k I i k Emission Class Control amp I O Code Control Safe Off Filtered N amp Standard N A A A amp B Frames Optional C D amp E Frames Standard c Enhanced No Not Filtered Gx Enhanced Yes N A amp B Frames Optional No longer available for sale x Not available as factory installed option for 600V ratings C D amp E Frames x 600V Frames A through D available only without filter Cat Code N 600V Frame E available only with filter Cat Code A Increases size to Frame B l Feedback j Feedback Comm Slot No Feedback Enhanced Control Code Network Type 5V 12V Encoder w Enhanced C ControlNet Coax 1 Control D DeviceNet B EtherNet IP N None Rockwell Automation Publication 20A TD001J EN P July 2014 PowerFlex 70 Adjustable Frequency AC Drive Approximate Dimensions and Weights This section provides the approximate dimensions
5. PowerFlex 70 Adjustable Frequency AC Drive Additional Resources These documents contain additional information concerning related products from Rockwell Automation Resource Description PowerFlex 70 Adjustable Frequency AC Drive User Manual publication 20A UM001 Provides the basic information needed to start up and troubleshoot the PowerFlex 70 Adjustable Frequency AC Drive PowerFlex 70 and 700 Reference Manual Volume 1 publication PFLEX RM001 Provides detailed information for specifications and dimensions operation and dynamic brake selection for the drive PowerFlex 70 Adjustable Frequency AC Drive Installation Instructions publication 20A IN009 Provides the five basic steps needed to install and perform a basic startup of the PowerFlex 70 drive Wiring and Grounding Guidelines for Pulse Width Modulated PWM AC Drives Provides the basic information needed to properly wire and ground Pulse Width publication DRIVES INO01 Modulated PWM AC drives Industry Installation Guidelines for Pulse Width Modulated PWM AC Drives Provides basic information for enclosure systems and environmental location publication DRIVES AT003 considerations to help protect against environmental contaminants and power and grounding considerations needed to properly install AC drives Safety Guidelines for the Application Installation and Maintenance of Solid State Control Provides general guidelines for the application inst
6. Technology to cover a wide range of applications from fans to extruders Optional internal communication modules provide fast and efficient control and or data exchange with host controllers over popular interfaces These interfaces include DeviceNet EtherNet ControlNet remote I O serial communications and other open control and communication networks Computer tools such as DriveExplorer and DriveTools SP assist with programming monitoring and troubleshooting the PowerFlex 70 2 Rockwell Automation Publication 20A TDOO1J EN P July 2014 Catalog Number Explanation Position Number PowerFlex 70 Adjustable Frequency AC Drive 9 10 11 12 13 14 15 16 3 A Y Y N N C 0 e f g h i j k I c3 05 ND Rating ND Rating 400V 50 Hz Input 600V 60 Hz Input Code Amps kW Hp Frame Code Amps kW Hp Frame 1P3 1 3 0 37 0 5 A OP9 0 9 0 37 0 5 A 2P1 24 0 75 1 0 A 1P7 1 7 0 75 1 0 A 3P5 3 5 1 5 2 0 A 2P7 27 1 5 2 0 A SBO 5 0 2 2 3 0 B 3P9 3 9 2 2 3 0 B 8P7 8 7 4 0 5 0 B 6P1 6 1 4 0 5 0 B 011 11 5 5 5 7 5 C 9PO 9 0 5 5 7 5 Cc 015 15 4 7 5 10 C 011 11 7 5 10 Cc 022 22 11 15 D 017 17 11 15 D 030 30 15 20 D 022 22 15 20 D 037 37 18 5 25 D 027 27 18 5 25 D 043 43 22 30 D 032 32 22 30 D 06
7. allation and maintenance of publication SGI 1 1 solid state control Preventive Maintenance of Industrial Control and Drive System Equipment Provides a guide to performing preventive maintenance publication DRIVES TD001 Guarding Against Electrostatic Damage publication 8000 4 5 2 Provides practices for guarding against Electrostatic damage ESD Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 Provides general guidelines for installing a Rockwell Automation industrial system Product Certifications website http www ab com Provides declarations of conformity certificates and other certification details You can view or download publications at http www rockwellautomation com literature To order paper copies of technical documentation contact your local Allen Bradley distributor or Rockwell Automation sales representative Product Overview PowerFlex 70 drives are designed to worldwide standards providing out of the box performance around the globe Available ratings include these options e 0 5 25 Hp output at 240V AC input e 0 5 50 Hp output at 480V AC input e 0 5 50 Hp output at 600V AC input The PowerFlex 70 drive can be used with a full featured LCD human interface module HIM that provides multilingual text for startup metering programming and troubleshooting Power The PowerFlex 70 can be programmed for either volts per hertz sensorless vector or vector control with FORCE
8. ronment Pollution degree Pollution degree 1 and 2 Pollution degree 3 and 4 See Table 19 on page 37 for descriptions of pollution degree rating All enclosures are acceptable for pollution degree 1 and 2 An enclosure that meets or exceeds IP54 NEMA UL Type 12 is required for pollution degree 3 and 4 Table 19 Pollution Degree Ratings According to EN 61800 5 1 Pollution Description Degree 1 No pollution or only dry non conductive pollution occurs The pollution has no influence 2 Normally only non conductive pollution occurs Occasionally a temporary conductivity caused by condensation is expected when the drive is out of operation 3 Conductive pollution or dry non conductive pollution occurs that becomes conductive due to condensation and is expected 4 The pollution generates persistent conductivity caused for example by conductive dust rain or snow Rockwell Automation Publication 20A TD001J EN P July 2014 37
9. s current limit 20 160 of rated current 200 of rated current typical 220 300 of rated current dependent on drive rating Line transients Up to 6000 volts peak per IEEE C62 41 1991 Control logic noise immunity Showering arc transients up to 1500V peak Power ride thru 15 milliseconds at full load Logic control ride thru 0 5 seconds minimum 2 seconds typical Ground fault trip Phase to ground on drive output Short circuit trip Phase to phase on drive output Altitude 1000 m 3300 ft max without derating Maximum surrounding air temperature without derating IP20 NEMA UL Type 1 flange mount IP66 NEMA UL Type 4X 12 indoor 0 50 C 32 122 F 0 50 C 32 122 F 0 40 C 32 104 F Cooling fan operation Frames A and C Frames B D and E Fan operates when power is applied Fan operates when power is applied and in Run condition Storage temperature all const 40 70 C 40 158 F Atmosphere Important Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas vapors or dust If the drive is not going to be installed for a period of time store the drive where it is not exposed to a corrosive atmosphere Relative humidity 5 95 non condensing Shock 15 g peak for 11 ms duration 1 0 ms Vibration 0 152 mm 0 006 in displacement 1 g peak Surrounding envi