Home
COUNT-100 / COUNT-200
Contents
1. from The customer assumes responsibility for all cost and risk incurred in transport for service Labelmate makes no other warranty of any kind expressed or implied or to suitability or fitness for a particular purpose No other person agent or reseller is authorised to give any warranties on behalf of Labelmate Any obligation to warranty other than that specifically addressed above is hereby disclaimed LABELMATE LLC 69 AVENUE ALPHONSE XIII 1180 BRUSSELS BELGIUM TEL 322 375 69 60 FAX 322 375 38 96 brussels labelmate com www labelmateeurope com LABELMATE User_C 100 200 CE 01 13 Original user manual COUNT 100 COUNT 200 Label Counter for use with CAT 3 Label Rewinders e Digital Circuitry for Accuracy and Repeatability e Pre set Counter e Stops Rewinder when Count is reached Remove all parts from the shipping container and verify contents PACKAGE CONTENTS e User Manual this document e COUNT 100 or COUNT 200 Counter Unit e Power Supply Module Retain the Shipping Container and Packaging for Storage and Transport SPECIFICATIONS Weight of the machine COUNT 100 7 42Kg COUNT 200 8 13Kg Max Label Roll Width Power Supply C 100 170mm 6 7 C 200 255mm 10 Input 220 240VAC 50 60Hz Output 12VDC e KEEP MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE e A WARNING This Product is for indoor use only Not for use in wet locations IMPORTANT INFORMAT
2. labels is reached the PC 1 Counter will issue a Halt Command for the CAT 2 Label Rewinder to stop Pressing RESET will reset the count and restart the CAT 2 See the included detailed manual for the Pre set Counter itself for other Counter options A FOR YOUR SAFETY Switch off device before any manipulation COUNTER USE 1 Place the COUNT 100 or COUNT 200 Label Counter so that it is perpendicular to the label web Observe the Paper Path Label on the Counter Feed the label web under the metal Rotating Paper Guide and over the Nylon Fixed Paper Guide Adjust the position of the rings on the Rotating and Fixed Paper Guides to the width of your label web Only finger tighten the screws The labels must pass through the black sensor slot between the round Paper Guides Affix the label web to the label rewind core on the Label Rewinder The Counter will count the number of labels passing through the sensor air gap NOTE If you observe erratic counting clean the Optical Sensor with isopropyl alcohol INTERNAL CIRCUIT PROTECTION The COUNT 100 and COUNT 200 Label Counters have an internal device for circuit protection There are no user serviceable parts inside In the event of operational problems please contact LABELMATE for assistance
3. ION This product is a label counter It is only to be used to count labels of the recommended dimensions in an indoor dry environment The machine has to be unplugged before any manipulation The machine is to be used on a flat surface if the surface is not flat it is to be fixed using the holes in the base plate Do not leave the power cable in a passageway The ambient light of the working area needs to be sufficient to avoid any risk The counter can be used in ambient temperatures of 2 C to 40 C Connection of the machine to the power source must respect local and European legislations PC 1 PRE SET COUNTER SET UP 1 Verify that the AC DC Adaptor VOLT CHANGE SW is set to 12 and plug it into a suitable AC Power Outlet Plug the Cord on the AC DC Adaptor into the Power Input Jack on the bottom of the Counter Display Module Plug the Control Cable with 3 5mm plugs at each end between the Output Jack on the bottom of the Counter Display Module and the EXTERNAL HALT CONTROL jack on the CAT 2 Label Rewinder The Counter is pre programmed as a Preset Count up Counter Press each of the 6 digits for the count desired This is the number of labels you wish to pass through the Label Sensor before the Counter issues a HALT command to the CAT 2 Label Rewinder Pull a short strip of labels back and forth through the Label Sensor Gap and observe the count on the Counter increasing When the preset number of
4. MAINTENANCE Your COUNT 100 COUNT 200 requires no maintenance Product Limited Warranty All Labelmate Products are warranted to the original end user customer to be free from defects in materials and workmanship If it is determined by Labelmate that a product has failed under the terms of this warranty the product will be repaired or replaced at no charge to the customer Labelmate reserves all rights to determination of coverage and liability under this warranty The warranty period for all new Labelmate products is outlined below Warranty Period Products Covered Label Rewinders meals Label Unwinders Label Counters mechanical parts only Label Slitters mechanical parts only Label Dispensers Printer Mechanisms Power Supply Modules Counter modules Encoders Any products not specified above The warranty period for all products starts on the date purchased by the original end user customer Warranty coverage is not transferable with ownership and will terminate immediately upon rental resale or any other change in ownership This warranty does not cover repair to any product which is damaged has been modified is missing parts or has been opened or repaired by any unauthorised person Use of any unauthorised accessory or attachment will void coverage Purchase documentation should be retained for coverage verification In the event your product requires service please contact the distributor you bought the product
Download Pdf Manuals
Related Search
Related Contents
EFIS 2.0 - Guide de dépannage do Manual - Dexter Rental Operating Instructions Fan Control Module (FCM) User and maintenance manual Návod k použití a údržbě Intel Xeon LF80550KF0604M processor cn Copyright © All rights reserved.
Failed to retrieve file