Home

WS Exp-elite keyboard entryphone system Installation

image

Contents

1. authorised the service by programming Releasing the intercom connection is done according to the releasing the speech condition paragraph Admission with the help of the outdoor unit keyboard Press the key symbol button on the outdoor unit then enter the 5 digit admission code With the correct code the door opener is activated IMPORTANT You must begin entering the PIN code in 3 seconds after pressing the key button otherwise the system will not allow the door to open from reasons of safety instead it will ring the apartment number corresponding to the first two digits note It is possible to adapt a PROXIMITY admission card accessory to the Exp Elite entryphone system The card based admission means higher safety with the admission 2 3 Summary of functions accessible for the user Programming the functions accessible for the user is done by an expert installer therefore ask the installer for the codes Function accessible for the user Code Switching on speech condition and extension of voice communication First door opening possibly barrier or admission turnstile Second door opening possibly barrier or admission turnstile Release of speech condition Intercom link Gate 1 control Gate 2 control Admission PIN cod 1 Admission PIN cod 2 Admission PIN cod 3 Admission PIN cod 4 Admission PIN cod 5 Admission PIN cod 6 Admission
2. Choosing the location of the installation 3 2 Cabling configuration 3 3 Choosing the appliances connected to the adapter unit Programming the equipment 4 1 Entering the programming mode 4 2 Programming the Exp elite adapter 4 3 Programming documentation Technical parameters 5 1 Operation characteristics 5 2 Electrical parameters 5 3 Joining attachments 5 4 Environmental characteristics I Introduction Dear User The entryphone system chosen by You has been designed according to the demands of the present day Today s microprocessor control makes a wide variety of services and their flexible programming possible The Exp Elite entryphone system is the result of many years development experience The two main constituting elements of the system are 1 the outdoor unit 2 the adapter unit The outdoor unit is the equipment installed at the entrance gate or door It provides the possibility to choose the apartment or to enter using a PIN code The adapter unit is the adapter that can be installed indoors or in water and vapour proof box which matches the outdoor unit to the analogue extention of the minor exchange stores the programmed operation parameters and directs the operation Furthermore a door magnet controller a barrier controller a Proximity or magnetic card admitter as well as an intercom loudspeaker can be connected to the adapter unit The connection of the above equipments has been configured but these devices do not
3. belong to the basic set To configure the operation to program it when put into operation a Laptop or a Desktop PC is needed through the V 24 RS 232 interface Programming and the programming documentation can be effected with the help of the Exp Elite communication software The programmed parameters in the adapter unit are stored in EEPROM therefore the parameters will be saved in case of a power outage 2 2 Functions accessible for the user Survey The outdoor unit of the entryphone is connected to the local minor exchange through the adapter unit A call from the outdoor unit pressing the apartment number will make the apartment telephone ring for a time set by the programmer By picking up the handset of the apartment telephone you can get into contact with the entryphone immediately or as the effect of the code to switch on the speech condition also as set by the programmer The opening of the door can be effected by entering the door opener code Reception of entryphone call The caller has selected the apartment he she desires to call by entering the apartment number The apartment telephone rings Picking up the handset you can hear the entryphone tone or the holding music switched on by the entryphone according to setting or you can immediately get into contact with the outdoor unit In case of holding music or tone you can activate the speech contact with the speech condition code Initiating a call to the e
4. cabling the equipment the operation characteristics must be set by programming Programming is done with the help of the Exp Elite support program through the V 24 RS232 interface Connect the PC with a D9 RS 232 cable to the adapter unit To enter programming mode turn the sliding switch on the side of the equipment to ON position The LED located next to the switch lights up Start the Exp Elite program on your PC and click the CONNECT button The software version of the adapter unit will appear on the screen and the issue date year and month as well as the communication protocol version number The equipment is now ready to be programmed If you get an error message you should check the coupling of the serial cable the serial cable and the position of the service switch 4 2 Programming the Exp elite adapter The adpter unit can be programmed as three units logically The programming parameters can be set on different sheets First sheet You can set the extention apartment call numbers and the spacing interval before the dialling on the first sheet Always take the particularities of the minor exchange into consideration when setting the spacing interval usually 2sec is recommended Second sheet The parameters of the outdoor unit can be set on the second sheet Voice communication code one digit Release code one digit Intercom link code one digit Contact timing delay Ringing time Speech condition timing Admitte
5. PIN cod 7 Admission PIN cod 8 Admission PIN cod 9 Admission PIN cod 10 3 1 Choosing the location of the installation The following points are to be considered when installing the outdoor unit The equipment should be out of reach for heavy rain and the microphone for dominant winds The outdoor unit should be stably fixed on a vibration free wall surface With a sunk execution you should make sure the wall notch is not damp mouldy or full of debris Rain should not leak in at the cable attachment The indoor adapter unit can be installed on a fixed wall surface or into a tight moisture and rain proof plastic electric equipment box The adapter unit should not be further than 50m from the outdoor unit if possible In case of a larger distance the use of 075 Cu cable is necessary 3 2 Cabling configuration The outdoor unit and the adapter unit are connected by three wires through which the communication and the power supply is realised In case this wire runs through an environment full of interference it is advisable to use a shielded wire for it in any case The shielding hose is only allowed to be connected at the adapter and to the negative point You should leave the shielding hose at the outdoor unit free to avoid a ground loop The adapter unit connects to the minor exchange at the line a b points to the branch line circuits Follow the instructions of the minor exchange wh
6. WS Exp elite keyboard entryphone system Installation and user information Dear Installer Colleague This manual is intended for you therefore we are asking you to read it before installing We will gladly answer any question you may have and gladly receive any observations or suggestions you would like to make Thank you for choosing our product The manufacturer developer SOUL DREAM Ltd Hungary EXP ELILE COMPLEX ENTRYPHONE CONTROL SYSTEM DRAFT SYSTEM ADAPTER EXP ELRE ANALOG EXTENTION OUTDOOR UNIT OPERATOR AND AMPLIFIER a MELLEKEK BE I ANALOG OR DIGITAL BE 2 MINOR EXCHANGE n DOOR OPENER BUTTON ADMISSION SYSTEM MAGNETIC CARD ADMISSION BARRIER CONTROL h PROXIIMITY READER ETC Rs232 VEHICLE ENTRANCE PC PROGRAMING 0 a INDOOR SPEAKER G K BEJARO INTERCOM COMMUNICATION APPLICATION 1 ALL RIGHTS RESERVED SOUL DREAM LTD HUNGARY 2002 The developer and the manufacturer reserves the right to change the contents of the manual and the contents referring to the equipment described in it The user s manual cannot be duplicated either patly or wholly without the expressed written consent of the manufacturer or the developer All rights reserved Table of contents Introduction The destination of the equipment 2 1 General information 2 2 Functions accesible for the user 2 3 Summary of functions accessible for the user Putting into operation 3 1
7. ch INI closing contact detector input terminal e g admitter unit or pressbutton IN2 current detector input terminal admitter unit OUTI first opening controller output terminal can be closing contact or 12VAC depending on programming OUT2 second opening controller output terminal only closing contact outdoor unit negative connection point outdoor unit audio frequency connection point gg outdoor unit positive connection point Outdoor unit triple terminal outdoor unit negative connection point outdoor unit audio frequency connection point outdoor unit positive connection point 5 4 Environmental characteristics Indoor unit Operation temperature range 0 60 C Relative vapour content 0 80 Outdoor unit Operation temperature range 15 60 C Relative vapour content 0 90
8. en determining the distance between the adapter unit and the minor exchange The door opener barrier control rotating fork etc control should always be realised with a separate wire There is no possibility to join wires 3 3 Appliances connected to the adapter unit The following optional units can be connected to the adapter unit With two gate controller units two magnetic locks or barriers and turnstiles can be controlled At the first controller output terminal we can determine by programming that it would ensure closing contact or 12VAC not stabilised voltage The second controller terminal only provides closing contact The loadability of the built in relay contacts is maximum 0 5A and the 12VAC loadability also is limited to a 0 5A amperage With connecting an Intercom loudspeaker we l have a one way voice communication possibility with workshops factory area and the reception The amplifier of the intercom can deliver a 1W audio frequency power output and the matching loudspeaker impedance can be 4 160Ohm Numerous devices like PROXIMITY or magnetic card admitter can be connected to the two controller input terminals The first input terminal can be activated by closing contact while the second is a power detector input terminal becoming active as the effect of current flowing through the it Each input terminal can be rendered to the appropriate output terminal by programming 4 1 Entering the programming mode After
9. ntryphone unit You have a possibility to call the entryphone unit e g when from the window you can see somebody waiting in front of the entrance door Picking up the handset of the apartment phone you will hear the dial tone of the minor exchange and now you can dial the call number of the entryphone extention then enter the code to switch on the speech condition Entering the code makes it possible for the voice communication to build up Releasing the speech condition There is a possibility to release the speech condition from the apartment phone by entering the release code on the apparatus and then putting down the handset of the apartment telephone Door opening You have the possibility to control the door opener from the home telephone In speech condition enter the door opening code two digit code By entering the first digit the speech condition is suspended to avoid undue entering and then the door opens after pressing the second key You can turn back to speech condition from the suspension of the speech condition with the code to switch on the speech condition Before the full release 5 seconds before the entryphone unit gives a notice sound Intercom link You are calling the entryphone unit from a home telephone and then by pressing the intercom key you can activate the one way voice communication The intercom communication is only available if you have installed an intercom loudspeaker to the adapter unit and if you have
10. r PIN codes Information sound signals Third sheet The door opener control the input and output terminal matching can be determined on the third sheet 4 3 Programming documentation It is a very important step at the end of the installation to document the installation You can make comments on the fourth sheet the characteristics of the installation hardware development possible special user demands The notes also will be saved when the configuration is saved and this can be very useful in the following There is a possibility furthermore to print the set parameters This is especially useful when delivering the system to help avoid future arguments Dear Installer Colleague We are further asking You to deliver the user codes programmed by You to the users and to instruct the users We can avoid a lot of misunderstandings and they will be satisfied with Your work in this way 5 1 Operation characteristics The Exp Elite entryphone adapter is a microcontroller controlled TPV telecommunication accessory equipment The programmed parameters in the adapter unit are stored in EEPROM therefore the parameters will be saved in case of a power outage 5 2 Electrical parameters Supply voltage necessity 220 230V 50 60Hz Maximum rate of power consumption 25VA Minor exchange extention terminating impendance 6000hm 5 3 Joining attachments Adapter unit LINE telephone minor exchange analogous branch circuit connector a b bran