1. What is the small alarm symbol in the tank This lets you know when your tank level is too quadrant high low This is fully customisable in the Tank Alarm Setup page in the Config Settings Offshore Systems UK Ltd Unit 10 11 Milton Business Centre Wick Drive New Milton Hampshire BH25 6RH United Kingdom Tel 44 0 1425 610022 Fax 44 0 1425 614794 Email mail osukl com Web www osukl com Copyright 2013 Offshore Systems UK Ltd All rights reserved Our policy is one of continuous product improvement so product specifications are subject to change without notice Offshore Systems products are designed to be accurate and reliable However they should be used only as aids to vessel monitoring and not as a replacement for traditional navigation and vessel monitorirg techniques NMEA2000 is a registered trademark of the National Marine Electronics Association YAOM SU e 8u s e uo p jjezsur aq ue JapUas Jo ed Yea oJ o dn J3UJJ0JSUPJ1 uoewoyzuj JUBWaseuewW en Rae ww000Z 0SZ uan 20 Su es Japuas Joie Eau 187 Er dWV 00Z i SAN 1032239Q JOWS WWO00Z 0SZ Japuas Jaye Aalen 87E amp e a uuu g00Z 0GZ a n Japuas Jaye La jere RR 251g L8ZE e ZS 4JOSU3S Joydepy Japuas sJmeJedulej yue 2AQSIS9Jq u u 0008 06Z sed ysneyxy OLGr Jepues a jen4 L t Joydepy 3 suy Ser e 49ppnJ SILE s Ar a H e j i e 10 tuoW 20 J De EEN soydepy deg J Owe JO LUOW DY mmaa 0 0g S JY
2. 4 2 3 3 BATTERY ALARM SETUP To set an alarm firstly select the instance using the up down buttons on the left if the battery instances have been given names this will also show up then press enter to select The first field enables or disables the alarm The next two fields are low high voltage alarm values When the 3345 Multi function display detects a voltage under the low voltage value or higher than the high voltage an alarm is displayed The last temperature field will show an alarm if the display detects a temperature higher than the set threshold The setup can be cancelled at any time using the exit button on the far right Please see next page Battery Alarm Setup Battery Instance Battery Alarm 0 Battery Name Enabled Battery Low Voltage 9 6 Volts Battery High Voltage 14 4 Volts Battery High Temp 25 C Up and Down Arrows t select battery MTER to setup 8 attery y Auma 4 2 4 EXTERNAL CONTROL SETUP This screen is used to set up the conditions to operate the 3478 Relay Output Module so that it can control external alarms external pumps and other relay controlled actions Firstly the user needs to select the Device Instance of the 3478 by using the following screen External Control Setup First select Relay Output Module Device Instance to match Switch Settings on the unit Device Instance 00 Press Up and Down Arrows to change Value Press Right Arrow to select next item Press ENTER to ee Externa
3. By pressing the BATT button the display will show information about the first two battery or DC sources as shown below Battery Name Temperature ZU GC state of Charge 80 Repeated pressing of the BATT button will display the next two batteries or DC sources to a total of 16 sources Each side of the display contains the following information 1 In the top centre of each side is the Battery or DC Source user assignable name When the unit is delivered each battery or DC source has a generic name that can be set to any name the user wishes to help identify the Battery or DC source See section 4 2 4 later in this manual for information on how to do this At the top left hand side of each side there is a Battery or DC Source Instance number which needs to correspond with the Instance of the DC Monitor supplying the data to the network The top display gauge is the current charging or being drawn from the battery DC source This gauge scale has our Autoranging feature so that if the current exceeds 60 amps the gauge scales will automatically autorange to a higher scale This gauge also includes a digital display panel showing the current flow numerically 4 The second display gauge shows the voltage of the battery or DC source also with autoranging between 12 and 24 volt systems and a digital display panel 5 At the bottom of each side is a battery temperature gauge 3 4 GENERATOR AC SOURCE SUPPLY By pre
4. Litres 020 00420 Press Up and Down Arrows to change Value SS Press Right Arrow to move the cursor Ss E Pre HIER to enter Volume or EXIT to quit The user then enters the volume of fluid at each desired level starting at the lowest chosen point in as many or as few steps to 100 Note that this screen is re presented at each step until the final level of 100 is entered When this happens the unit calculates all the intermediate levels and stores that information in the chosen sender 4 2 2 3 FLUID UNITS SETUP This screen is used to choose between displaying the Fluid Units in Litres US Gallons or Imperial Gallons as can be seen by the following screen Fluid Units Setup Tank Volume Display Units are set up by using the keys below to select and store them Display Units Litres Up and Down Arrows to change Units ENTER to store Units are Gre Gus Gan P The user can change the units by using the UP and DOWN arrows and pressing ENTER to select their units of choice Pressing EXIT will return to the SETTINGS MENU 4 2 2 4 TANK ALARM SETUP This screen is used to set the Tank Level Alarm settings for each tank Tank Alarm Setup Tank Type Fuel Tank Instance Low Level Alarm Status Off Low Level Alarm Level 0 i High Level Alarm Status Off High Level Alarm Level 0 g Up and Down Arrows to change Value s Right Arrow to select next item ENTER to store Tank
5. and Device Instances as required by the standard The System Instance is normally set on 0 but if the NMEA2000 network is linked to other networks then the System Instance of each 3345 should be set to match the network instance that it is set to Unless the networks are linked the System Instance should be set 0 The Device Instance of each 3345 on a given NMEA2000 network should be set to a different number to differentiate between each 3345 The first 3345 should be set to Device Instance 0 and then each subsequent 3345 should have a different unique device instance Please see next page sys amp Dev Instances System and Device Instances are set up by using he keys below to adjust and store them system Instance Device Instance Pres p and Down Arrows to change Instance 55 Li Press Right Arrow to select other Instance Press ENTER to store Instances nd 2 e 2 AS The user should use the UP and DOWN arrows to change the value of the Instance that is underlined and then use the RIGHT arrow to select the other Instance When the Instance values are correct press ENTER to store them and EXIT to return to the Settings Menu 4 2 7 CONFIG PIN SETUP This screen is used to change the Configuration PIN to a new number if required Config PIN Setup Configuration Settings on this devi by PIN entry Use the keys below t store your PIN Ce are pr PIN 0 0 0 Press Up and Down Ar
6. 6 127507 Battery Status AC Monitors 16 127508 DC Detailed Status 127744 AC Power 127745 Phases A B C 127746 127747 AC Voltage Freq 127748 Phases A B C 127749 Electrical and Mechanical Operating Voltage 10 to 32 Volts Power Consumption 250mA Load Equivalence Number 5 Reverse Battery Protection Indefinitely Load Dump Protection Size Yes to SAE J1113 95mm W x 95mm H x 23mm forward and 23mm rear D Weight 160gm Environmental IEC 60954 Classification Protected Degree of Protection IP67 Operating Temperature 20 to 70 C Storage Temperature 30 to 80 C Relative Humidity 93 RH 40 per IEC60945 8 2 Vibration 2 13 2Hz 1mm 13 2 100Hz 7m s2 per IEC 60945 8 7 Electromagnetic Emission Conducted and Radiated Emission per IEC 60945 9 Electromagnetic Immunity Conducted Radiated Supply and ESD per IEC 60945 10 Safety Precautions Dangerous Voltage Electromagnetic Radio Frequency per IEC 60945 12 TECHNICAL SUPPORT If you require technical support for any Offshore Systems products you can reach us using any of the following ways e Tel 44 0 1425 610022 e Fax 44 0 1425 614794 e Email support osukl com e Web www osukl com e Post Offshore Systems UK Ltd Unit 10 11 Milton Business Centre Wick Drive New Milton Ham
7. Alarm Values The user can select both low and high level alarms for each tank and the alarm level for each type of alarm By pressing the UP and DOWN arrows the value in the highlighted line will change By pressing the RIGHT arrow the selector will highlight the Tank Type Tank Instance Alarm Type Status and Alarm level for each alarm type When the selected alarms have been set press the ENTER key to store them and then the EXIT key to return to the settings menu 4 2 2 5 PERCENT ONLY DISPLAY ON OFF This is a toggle menu item which will always show the fluid level numeric value in percent rather than amount 4 2 3 BATTERY SETUP BATTERY SETTINGS MENU 4 2 3 1 BATTERY NAME SETUP This screen is used to assign a 16 character name to each battery to identify the battery more easily on the battery display pages as can be seen on the following screen Battery Name Setup Batteries being monitored by this display can have a 16 character name assiane d to identify them easily Battery Instance 0 Name Battery vO Press Up and Down Ari s to select battery Press ENTER to setup Battery Name Firstly by pressing the up arrow and down arrow buttons select the battery instance or battery number to be named then press ENTER Battery Name Setup Batteries being monitored by this display can have a acter name assianed to identify them easily Battery Instance 0 Name Engine Bat
8. ESSLY IN LIEU OF AND EXCLUDES ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE Statements made by any person including representatives of Offshore Systems which are inconsistent or in conflict with the terms of this Limited Warranty shall not be binding upon Offshore Systems unless reduced to writing and approved by an officer of Offshore Systems IN NO CASE WILL OFFSHORE SYSTEMS BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE INNO EVENT SHALL OFFSHORE SYSTEMS AGGREGATE LIABILITY EXCEED THE PURCHASE PRICE OF THE PRODUCT S INVOLVED OFFSHORE SYSTEMS SHALL NOT BE SUBJECT TO ANY OTHER OBLIGATIONS OR LIABILITIES WHETHER ARISING OUT OF BREACH OF CONTRACT OR WARRANTY TORT INCLUDING NEGLIGENCE OR OTHER THEORIES OF LAW WITH RESPECT TO PRODUCTS SOLD OR SERVICES RENDERED BY OFFSHORE SYSTEMS OR ANY UNDERTAKINGS ACTS OR OMISSIONS RELATING THERETO Offshore Systems does not warrant that the functions contained in any software programs or products will meet purchaser s requirements or that the operation of the software programs or products will be uninterrupted or error free Purchaser assumes responsibility for the selection of the software programs or products to achieve the intended results and for the installation use a
9. Here we can see that the Tank Display screen is split into 4 quadrants so the user can monitor 4 tanks at once The centre of the screen at the junction of the four quadrants displays the Quadrant Page Number which in the above case is Page 0 The display has eight different pages available which are selected by repeatedly pressing the TANK button which will progressively step through each display page This allows the user to display up to eight pages each of four tanks to a total of thirty two tanks Each quadrant of the above display contains the following information 1 In the top centre of the quadrant is the user assignable tank name When the unit is delivered each tank type has a generic tank type name that can be set to any name the user wishes to help identify the tank See section 4 2 3 later in this manual for information on how to do this 2 At the top left hand side of the quadrant is the Tank Number or Instance which needs to correspond with the number set on the tank sender Address or Instance switch 3 At the top right hand side of the quadrant not shown above there may be a small alarm bell symbol which indicates that this tank level is outside it s alarm level limits and the alarm has been notified and acknowledged by the user See the section on Tank Level Alarms in section 4 2 6 4 In the centre of the quadrant is a gauge showing the tank level volume per centage and a pictogram of the tank type 5 In the lower p
10. NMEA2000 MULTIFUNCTION DISPLAY Part Numbers 3345 VE OVE USER MANUAL Revision 1 0 Contents 1 Introduction 1 1 Firmware Revision 1 2 Product Features 2 Installation 2 1 Unpacking the box 2 2 Mounting the unit 2 3 Connecting the NMEA2000 Interface Cable 3 Display Screens 3 1 Screen Keypad Brightness Control 3 2 Tank Display 3 3 Battery DC Source Supply 3 4 Generator AC Source Supply 4 Configuration 4 1 Config Menu 4 2 PIN Entry 4 2 1 Settings Menu 4 2 2 Tank Setup 4 2 2 1 Tank Name Setup ENNEN 12 4 2 2 2 Tank Volume Calibrate 4 2 2 3 Fluid Units Setup 4 2 2 4 Tank Alarm Setup 4 2 2 5 Percent Only Display 4 2 3 Battery Setup 4 2 3 1 Battery Name Setup 4 2 3 2 Battery Config Setup 4 2 3 3 Battery Alarm Setup 4 2 4 External Control Setup 4 2 5 AC Setup 4 2 5 1 AC Source Name Setup 4 2 5 2 AC Custom Setup 4 2 6 Sys amp Dev Instances 4 2 7 Config PIN Setup 4 3 Com Viewer 4 4 Demo On Off Toggle 4 5 About 5 Maintenance 6 Technical Specification 7 Technical Support 8 Warranty 9 Troubleshooting FAQ D INTRODUCTION The Offshore System s NMEA2000 3345 MultiFunction Display is designed to monitor and display information about the vessel s tanks DC supplies such as battery banks Wind Generators or Photovoltaic panels and AC Supplies such as generators shore power or AC busses This unit is designed to operate in a protected marine environment such as at the helm chart tab
11. S Br n SES 0Z WK EK E e 4oydepy erer a npow ndu pee enq G8le U2 1MS Ort de 4 49M0d ZEBE sJ0322UUuo 2 qe SU PILH u jue g e e ep LOS _ Jayaw d aide MNG OZ8E J0 i J0 2UlUl J seJn oeJnuew ut u7 snoren 0 se qe Joydepy Jopuuu jet i s e eW OL B G Z L S O ayewa 08 Jo depv ZOBE S SP10 gt OJOIW 618 0198 soydepy 1 191nW F Z08 D Les Les A T m gt ke u5noJ u pee4 pesyying z08 Aeien Josuas aunjyesodwiay yoeig wooy aut ug passny G7Gr y gend 7 se neo d Jaysues OSES samiy janan mm Te SK _ GE aqoid aunyesadwiay N Kemayeg snqpow ssi N p nb 1 ezey Ae ds q YNO Sh PUL OU VOX GIL 0LI VOAM ZObr ypeig ysaly any saBne jaca yueL OSEE heydsig uonouny DIN SPEE ane jem 42d O1ZE yndyno Agen Sitt a npow sinyessdway 4JOSUSS sunyesodwiay diy utge ZZGF euueu y L t SWALSAS TOYLNOD QNV DNIYOLINOW l4SS43A 000ZV4WN dVW LONGOYd SWALSAS AYOHSAAO
12. art of the quadrant is a digital display panel This panel will show the tank level as a percentage ie 45 if the total tank volume is not being trans mitted by the sender If the sender is transmitting the total tank volume as well as the tank level then the digital display panel will show the remaining fluid volume in either Litres US Gallons or Imperial Gallons as chosen by the user configuration in section 4 2 2 below 6 The gauge arc will display partially in red not shown if either the low or high level alarm has been set to a suitable value and the alarm has been enabled See section 4 2 6 later in this manual for information on how to do this The user can select which tanks are displayed on each quadrant of each Quadrant Page by pressing the TANK button to bring up the button bar then pressing the RIGHT ARROW button which will alter the buttons to allow each quadrant to be changed Fresh Tank Pressing the first button the top left hand quadrant will change to display each of the different tank sender levels being received and then a blank page in case the user does not wish to display any tank in a given quadrant Then by pressing the BACK ARROW button that selection will be remembered and the display will revert to the normal tank display This can be repeated for each quadrant on each Quadrant Page giving the user the opportunity to tailor the tank displays exactly as they wish 3 3 BATTERY DC SOURCE SUPPLY
13. ata about the unit including the software version and unit serial number Version ABOUT Part No 3345 MultiFunction Display 3 00 B11 K22 RF33 1300 123456 d which will identify the exact unit if requested There is no further action from this screen and pressing the EXIT button will return you to the CONFIG MENU detailed in 3 1 above e Clean the unit with a soft cloth e Do not use chemical cleaners as they may remove paint or markings or may corrode the enclosure or seals e Ensure that the unit is mounted securely and cannot be moved relative to the mounting surface If the unit is loose tighten the mounting screws e Check the security of the cables connected to the NMEA 2000 connector tighten if necessary 6 TECHNICAL SPECIFICATION As Offshore Systems are constantly improving their products specifications are subject to change without notice Offshore System s products are designed to be accurate and reliable however they should only be used as aids to navigation and not as a replacement for traditional navigation aids and techniques Certifications NMEA2000 Level B Maritime Nav and RadioComm Equipment IEC60945 CE and FCC Electromagnetic Compatibility NMEA2000 Parameter Group Numbers PGNs Source Max No PGN Description Fuel Tanks 16 127505 Fluid Level Fresh Water Tanks 16 Grey Water Tanks 16 Black Water Tanks 16 Oil Tanks 16 DC Sources Battery Banks 1
14. cket The other end of the cable should be connected to a nearby NMEA2000 Tee connector part number 3802 The male end of the cable should be inserted into the female Tee connection noting the position of the keyway in the plug and the socket Ensure that the locking ring is securely tightened so that the connection remains waterproof and sound DISPLAY SCREENS When the unit powers on it displays the initial product identity screen for a few seconds and then displays the Tank Display 3 1 SCREEN KEYPAD BRIGHTNESS CONTROL The unit has five tactile buttons along its lower face and pressing any of the first four buttons will bring up the button bar which identifies the current button function Pressing the required button will then execute the function chosen and the button bar will disappear a few seconds later leaving the whole screen displaying the required data The fifth button allows the user to vary the screen brightness and keyboard illumination which is shown below Pressing the first two buttons varies the screen brightness and the next two buttons vary the key backlights When the desired levels have been set press the fifth button to clear the display brightness control 3 2 TANK DISPLAY The first display screen is Page 0 of the tank levels volumes display and this can always be selected by pressing the first or most left hand button on the unit An example of this display is shown on the next page Fresh Tank
15. e named then press ENTER Tank Name Setup Tanks being monitored by this display can have a 16 character name assianed to identify them easilv Tank Type Fuel Tank Instance 0 Name Port Fuel Tank Press Up and Down Arrows to change character Press Right Arrow to select next character Press ENTER to save tank name Next use the UP and DOWN arrow keys to change the first character of the name then press the right key to move to be able to change the next character and so on Please note that the characters will cycle through A to Z upper case then a to z lower case then a blank then numbers from 0 to 9 4 2 2 2 TANK VOLUME CALIBRATE This screen is used to set the volume calibration table inside an Offshore System s 3271 or 3281 Tank Level Sender The first screen allows the user to choose the tank type and tank instance of the sender to be calibrated Tank Volume Calibrate First select tank type and instance to be volume calibrated NOTE Sender MUST be S W version 4 1 or later Tank Type Fuel Tank Instance 0 Press Up and Down Arrows to change Value Press Right Arrow to select next item Press ENTER to do Volume Calibration When these have been chosen press ENTER to go to the next screen Tank Volume Calibrate Next enter tank volume at each chosen level NOTE entering volume for 100 level will store the data into the sende Tank Type Fuel Tank Instance 0 Level Volume in
16. ill start the Config Menu 4 1 CONFIG MENU CONFIG MENU __ SETTINGS PIN Reqd _ _ DIAGNOSTICS DEMO OFF ABOUT On this menu use the up and down arrow keys to change the yellow highlight to the action required and then press ENTER This menu allows you to do four things 1 To go into the PIN protected settings menu to change the unit s settings 2 To look at the communications traffic This is an engineering function not normally used 3 To flip the unit in and out of Demo mode 4 To display the about screen to check on version levels and serial numbers etc The use of these options is described on the next page 4 2 PIN ENTRY By moving the yellow highlight to SETTINGS PIN Reqd and pressing enter the display will show the CONFIG PIN ENTRY screen to allow the user to enter a security PIN to access the configuration screens This is designed to ensure that only authorised persons can make changes in this area CONFIG PIN ENTRY Configuration Settings on this device are protected by PIN entry After entering the PIN correctly then the settings menus will be available PIN 0 0 0 s Up and Down Arrows to change digit s Right Arr to select next digit s ENTER te submit PIN Pres Pres Pres By using the Up and Down and Right arrow buttons the user selected PIN can be entered and the ENTER key will go to the SETTINGS MENU if the PIN is correct If the PIN is not correct
17. l Controls When the Device Instance has been chosen pressing ENTER will go to the next screen to allow choice of the actions to operate each of the eight relays in the 3478 unit External Control Setup R Tank Type Inst Activate when Fuel 0 Level above Fuel Black Water Fuel Fuel Fuel Level below LA LA sech Level above Not Active Not Active Not Active Fuel Not Active Fuel Not Active Press Up and Down Arrows to change Value Press Right Arrow to select next item Press ENTER to setup External Controls A P The user can select the Tank Type the Tank Instance the Activation trigger and the activation level in 5 steps When this is done pressing ENTER sets up the system to issue relay controls every time a level passes the activation threshold 4 2 5 AC SETUP AC SETTINGS MENU AC Source Name Setup AC Custom Setup 4 2 5 1 AC SOURCE NAME SETUP This screen is used to assign a 16 character name to each AC Source to identify it more easily on the AC Source display pages as can be seen on the following screen AC Source Name Setup AC Sources being shown on this display can have a 16 character name assianed to identify them easily AC Source Instance 0 Name AC Source O AC Source Firstly by pressing the up arrow and down arrow buttons select the AC Source instance to be named then press ENTER AC Source Name Setup a e Up and Down Arrows to change character w Right Arrow t
18. le or an engine room It is very important that it is installed and set up correctly according to this manual Please read and follow the installation and setup instructions carefully to achieve the best results The information in this manual corresponds to firmware v3 0 1 2 PRODUCT FEATURES The NMEA2000 3345 MultiFunction Display has the following features e Full Colour Sunlight Readable QVGA Display e Pages displaying Tank DC and AC source information e User Selectable high and low level alarm limits e User Selectable Display Units e PIN protected setup and configuration e NMEA2000 Interface INSTALLATION 2 1 UNPACKING THE BOX You should find the following items in the 3345 shipping box 1 x 3345 NMEA2000 3345 MultiFunction Display 1 x 3345 NMEA2000 Interface Cable 1 x Bag containing 4 mounting studs and thumbwheel nuts 1 x 3345 User Manual This document 2 2 MOUNTING THE UNIT The unit should be mounted to a flat surface by the 4 mounting studs and thumbwheel nuts Use the following unit drawing to identify the positioning of the central clearance hole and the 4 mounting stud locations PRIMARY CONNECTOR MATES WITH DT04 12PA SECONDARY CONNECTOR MATES WITH DT04 12PB 2 3 CONNECTING THE NMEA2000 INTERFACE CABLE The NMEA2000 interface cable rectangular plug should be plugged into the rear of the unit taking care to observe the orientation pips on the plug match the corresponding recesses on the unit s so
19. nd results obtained from said programs or products No specifications samples descriptions or illustrations provided by Offshore Systems to Purchaser whether directly in trade literature brochures or other documentation shall be construed as warranties of any kind and any failure to conform to such specifications samples descriptions or illustrations shall not constitute any breach of Offshore Systems limited warranty Warranty Return Procedure To apply for warranty claims contact Offshore Systems or one of its dealers to describe the problem and determine the appropriate course of action If a return is necessary place the product in its original packaging together with proof of purchase and send to an Authorized Offshore Systems Service Location You are responsible for all shipping and insurance charges Offshore Systems will return the replaced or repaired product with all shipping and handling prepaid except for requests requiring expedited shipping i e overnight shipments Failure to follow this warranty return procedure could result in the product s warranty becoming null and void Offshore Systems reserves the right to modify or replace at its sole discretion without prior notification the warranty listed above o TROUBLESHOOTING FAQ Please note that below are some FAQ Troubleshoot Questions If none of these help or apply then please don t hesitate to contact Technical Support Quadrant s are showing as empty
20. o select next character ENTER to save AC Source name Next use the Up and down arrow keys to change the first character of the name then press the right key to move to be able to change the next character and so on Please note that the characters will cycle through A to Z upper case then a to z lower case then a blank then numbers from 0 to 9 When the desired name has been written press ENTER then EXIT to store that name 4 2 5 2 AC CUSTOM SETUP This screen allows you to select an Offshore Systems AC monitor by instance and change its properties First select the instance using the UP DOWN arrows on the left if the battery instances have been given names this will also show up then press ENTER button to select A new right arrow button will appear once the instance has been selected Once you have selected the instance you use the UP DOWN arrows to change the value and the ENTER button to proceed into the next field Once all the fields have been selected the last press of the ENTER will save the configuration You can press the exit button on the far right to cancel the setup of the device at any time AC Custom Setup AC Source Instance Name AC Source O Offshore Device ka AC Circuit Type AC Voltage Type Press Up and Down Arrows to select AC Source Press ENTER to setup AC Circuit Type BA AW 4 2 6 SYS amp DEV INSTANCES This screen is to set the NMEA2000 System
21. pshire BH25 6RH Offshore Systems warrants this product to be free from defects in materials and workmanship for one year from the date of original purchase If within the applicable period any such products shall be proved to Offshore Systemssatisfaction to fail to meet the above limited warranty such products shall be repaired or replaced at Offshore Systems option Purchaser s exclusive remedy and Offshore Systems sole obligation hereunder provided product is returned pursuant to the return requirements below shall be limited to the repair or replacement at Offshore Systems option of any product not meeting the above limited warranty and which is returned to Offshore Systems or if Offshore Systems is unable to deliver a replacement that is free from defects in materials or workmanship Purchaser s payment for such product will be refunded Offshore Systems assumes no liability whatsoever for expenses of removing any defective product or part or for installing the repaired product or part or a replacement therefore or for any loss or damage to equipment in connection with which Offshore Systems products or parts shall be used The foregoing warranties shall not apply with respect to products subjected to negligence misuse misapplication accident damages by circumstances beyond Offshore Systems control to improper installation operation maintenance or storage or to other than normal use or service THE FOREGOING WARRANTIES ARE EXPR
22. rows to change digit Press Right Arrow to select next digit Press ENTER to store PIN The user can use the UP and DOWN arrows to change the value of the underlined PIN number and then use the RIGHT arrow to choose the next number to change When the desired PIN number has been chosen pressing the ENTER key will store it and then pressing the EXIT key will return to the settings menu 4 3 COM VIEWER By moving the yellow highlight to DIAGNOSTICS and then to COM VIEWER and pressing ENTER the unit will display the communications traffic arriving to the device This is shown below 40 Ez 21 14 D AO AO CO nu OO O O oo ooo WD CC DI D 0 0 D D 0 0 D D 0 0 D D 0 This is an engineering diagnostic screen and not normally used Press EXIT to return to the CONFIG MENU detailed in 3 1 above 4 4 DEMO ON OFF TOGGLE By moving the yellow highlight to the DEMO position and pressing the enter key demo mode can be selected During demo mode the unit produces its own demo signals to demonstrate the displays Under normal use the DEMO mode should be off Press EXIT to return to the normal display screens 4 5 ABOUT By moving the CONFIG MENU yellow highlighted selection to ABOUT and by pressing enter you will see a screen similar to that below Version Software Version Firmwa Version Serial Noa LEN This screen displays d
23. spaces after When adjusting tanks in quadrant spaces if an changing tanks unpainted blank gauge is applied to a quadrant it will show as a blank space can t remember my PIN number for the System Contact Technical Support and ask for the Config Menu Master PIN when you are in to the System Config Menu you can reset the PIN Tank Battery Names have disappeared when Exit the setup without saving the name When editing them in the Name Setup you re enter the name should reset to the Default Name It isn t displaying the correct Fuel Water level Check the sender instance matches with the tank instance being monitored Check the sender has been properly calibrated If not re calibrate with a magnet as shown on Fuel Sender Installation Instructions Not all of the senders are available to paint in To save time scrolling through every tank the quadrants sender aswell as its 16 instances it will only scan through the senders which it has seen transmitting onto the NMEA2000 Network What is the difference between the System The Device Instance is the 3345 s instance Instance and Device Instance whereas the System Instance is the NMEA Network s instance These should both match for the 3345 to work Is the 3345 Waterproof The 3345 is not completely waterproof it is water resistant to IP67 this means it s protected from dust and Protected against the effects of immersion in water to depth between 15 cm and 1 meter
24. ssing the ACPWR button the display will show information about the first two AC Generators or AC Busses or Shore Power as shown below AC Source D 257 5 vol 248 2 vol Frequency 60 3 Hz Frequency 60 3 Repeated pressing of the ACPWR button will display the next two AC sources to a total of 16 sources Each side of the display contains the following information 1 In the top centre of each side is the AC Source user assignable name When the unit is delivered each AC source has a generic name that can be set to any name the user wishes to help identify the AC source See section 4 2 5 later in this manual for information on how to do this 2 At the top left hand side of each side there is an AC Source Instance number which needs to correspond with the Instance of the AC Monitor supplying the data to the network 3 The top display gauge is the current being drawn from the AC source This gauge also includes a digital display panel showing the current flow numerically 4 The second display gauge shows the voltage of the AC source also with autoranging between 110 and 240 volt systems and a digital display panel 5 At the bottom of each side is an AC Source frequency gauge CONFIGURATION There are a number of configurable settings on the 3345 to allow the user to configure the unit to most closely match their requirements These are accessed by pressing and holding the right hand button for at least 5 seconds which w
25. tery Press Up and Down Arrows to change character Press Right Arrow to select next character Press ENTER to save battery name Next use the UP and DOWN arrow keys to change the first character of the name then press the right key to move to be able to change the next character and so on Please note that the characters will cycle through A to Z upper case then a to z lower case then a blank then numbers from 0 to 9 When the desired name has been written press ENTER then EXIT to store that name 4 2 3 2 BATTERY CONFIG SETUP This screen allows you to select an Offshore Systems DC monitor by instance and change its properties First select the instance using the UP amp DOWN arrows on the left if the battery instances have been given names this will also show up then press enter to select A new right arrow button will appear once the instance has been selected To change the values you use the UP amp DOWN arrows and to proceed to the next field you use the RIGHT arrow Press the ENTER button at anytime to save the configuration Battery Config Setup DC Type Battery Type Supports Equalisation Nominal Voltage Battery Chemistry Battery Capacity Battery Temp Coef Peukert Exponent Charge Eff Factor Battery Flooded He 12 Valts Lead Acid 100 Amp Hours KA 1 20 100 Press Up and Down Arrows to select battery Press ENTER to setup Battery Configuration
26. the user is offered the choice to re enter the PIN or exit back to the CONFIG MENU detailed in 3 1 above The system is shipped with a PIN of 0000 and this can be reset to the user s choice from the SETTINGS MENU CONFIG PIN SETUP 4 2 1 SETTINGS MENU The SETTINGS MENU offers multiple options as shown below SETTINGS MENU Note the small arrow on the left hand screen indicates that there are more options than can be shown on one page All these options and the ones not shown are accessed by moving the yellow highlighter to the chosen option and then pressing ENTER 4 2 2 TANK SETUP TANK SETTINGS MENU 4 2 2 1 TANK NAME SETUP This screen is used to assign a 16 character name to each tank to identify the tanks more easily on the tank display pages as can be seen on the following screen Tank Name Setup Tanks being monitored by this display can have a 16 character name assianed to identify them easily Tank Type Fuel Tank Instance 0 Name Fuel Tank Press Tank Type to select Tank Type Press Up and Down Arrows to select tank instance Press ENTER to LEE Ta nk Name Firstly the user must select the tank type that is being named by pressing the TANK TYPE button This will cycle around all the available tank types and the display must be left on the type of tank to be named Secondly by pressing the UP arrow and DOWN arrow buttons select the tank instance or tank number to b