1. nnn nnn 7 4 2 Rear E EE DEDE ERES EETU ET 7 SYSTEM CONNECTIONS iicet uera rx ak Sk b turi arto be d ae y ck t b Ra a 8 8 5 2 Web Server 0 0 9 92 MP 10 5 4 Encoder Configuration 9929 nes 11 5 5 Web Server DISCO Si 12 5 6 IP Settings 12 5 7 Decoder Configuration RE Ck ue 13 STREAMING Deux doa ure ERE Ead TR 14 6 1 Transport Stream TETTE 14 62 Real Time Transport Protocol 2 2 06 14 APPENDIX A SERIAL uaque 15 15 7 2 System oiii 16 Technology LL 1 0 GENERAL INFORMATION 1 1 Preface The Z3 MVE 20 is a 1 RU rack mount system capable of processing two channels multi format HD video and integrated system periph
2. Technology LLC Local Netmask 255 255 0 0 Default Gateway 192 168 0 1 5 5 Web Server Decoder 1 Stop the Encoder by pressing Stop Encoder on the web server 2 Select the Decoder option in the Operating Mode section to change the operating mode to Decoder The title in the top right of the browser should now say MVE 20 Decoder as pictured here in the example 5 6 IP Settings Decoder 1 Press Stop Decoder on the Decoder Control menu 2 Once the decoder has stopped type in your desired IP settings 3 Hit Save User to save your desired settings 4 Power cycle the Z3 MVE 20 5 The new IP settings will now take effect 20 Decoder 7 Firmware version 1 3 1 Technology LLC device name MVE 20 satname setpass logout Operating Mode Decoder Input Selection Output Setup Input Interface Ethemet Output Interface SDI Input Format RTP Y Video Format Follcw Input IP Port Video Frame Rate 50Hz Decoder Setup Local IP Setup Video Codec 254 M Local IP Address 132 168 0 5 Audio Codec X Local Netmask 255 255 0 0 Ilag Defzult Gateway 132 160 0 1 Decoder Control Load Factory Default Luud Factury Stup Devuder Start Decoder Load User Settings Loud User Staus User presets Save User Settings Suve Use Page 12 Technology 5 7 Decoder Configuratio
3. 1 Component Analog Jacks 1 AAC LC ADTS 64 kbits Follow input CBR 8000k High 60 Frames 1000ms H 264 None Ethernet RTP 225 454 2 3 8888 12000 1 1 192 168 0 65 1 255 255 0 0 1 192 168 0 1 Start Refresh Menu Exit Page 15 Technology LL 7 2 System Menu Control R Resolution Follow Input Custom 720p 1080i D1 NTSC D1 PAL 4 CIF 2 CIF CIF QCIF 15 Frames 30 Frames 60 Frames 120 Frames 240 Frames B Bitrate Custom 50k 64k 128k 250k 500k 750k 1500k 2000k 2500k 3000k 3500k 4000k 12000k P H 264 Profile Baseline Main High Fast min init max minlntra maxlntra Example 5 28 48 0 40 means Inter frame ranges from 5 to 48 Initial QP of 28 Intra frame ranges from 0 to 40 Minimum allowed is 0 maximum is 51 C Rate Control Mode CBR VBR Storage E Scan Mode Interlaced Progressive D Delay Limit 150ms 300ms 500ms 1000ms 2000ms Y H 264 QP Range H 264 QP range format 8 0 DYNAMIC BIT RATE amp FRAME RATE CHANGE The dynamic bit rate and frame rate control will take effect if you change the following parameters Video Bit Rate Frame Decimation After the Video Bit Rate and Frame Decimation rate have been configured to your preferred settings hit the Start Encoder or Restart Encoder button Page 16 3 Technology LL page wil
4. 3 Technology 23 Technology User s Manual Dual Channel HD H 264 Encoder Model Name Z3 MVE 20 Version 1 0 4 November 2 2011 Before attempting to connect or operate this product please read these instructions carefully and save the manual for future use Z3 Technology Tel 1 402 323 0702 www z3technology com sales z3technology com Page 1 Revision History Technology Version Date Change Note Author 1 2 2 8 29 11 Original System CH 1 2 6 9 1 11 Firmware Upgrade CH 1 3 1 11 2 11 Firmware Upgrade Edited Images CH 1 0 4 2 13 12 Associated version number with software release version Added CH Troubleshooting section Page 2 1 0 2 0 3 0 4 0 5 0 6 0 7 0 TABLE OF CONTENTS PAGE GENERAL INFORMA LION HR ERRREESRENMRERCIEE KPERR ERE 4 EE c 4 14 2 JADOUL INC IVGINUAl MEE 4 PARTS LIST em X hs cog aap ee oop ee Sean 5 21 cluded PAS vos 5 2 2 Optional ACCOSSONCS 5 6 OPERATING a pneu ah RA RO EQ DURER RC NN 7 4 1 FONE 1 0 1 160
5. Use direct connection from Z3 MVE 02 to PC without router customer network Once video connection is established then add in customer specific network equipment Second check to make sure firewalls are turned off Third check video source Verify video source is outputting compatible analog video Fourth verify PC is fast enough and has enough DDR to decode compressed video Fifth verify VLC version is 1 1x or later Page 17 7 LLC No SDP file o Check your Z3 server account Page 18
6. LC ADTS Dest IP Address 192 168 3 26 Audio Rate 64 kbits Dest Port 8888 Video Resolution Follow Input Rate Control CBR Video Bit Rate 6000k PID Audio Video PCR Video Profile High Local IP Setup Gop Size 30 Frames Local IP Address 192 168 0 65 Video burst size 1000ms Local Netmask 25525500 Adeo Codec 264 Default Gateway 192 168 0 1 Frame Decimation 1 2 Stop Encoder Start Encoder J Status Saved all to User Load Factory Default Settings Load Factory Load User Settings LoadUser Save User Settings SaveUser Page 10 wt Technology 54 Encoder Configuration Options Encoder Setup Audio Source Analog Jacks Channels 1 2 Channels 3 4 Channels 5 6 Channels 7 8 Audio Codec AAC LC ADTS AAC LC LATM AAC HE ADTS AAC HE LATM PCM MP3 AC 3 Passthru None Video Resolution Follow Input 1080i 1920x1080 3 4 1080i 1440x1080 XGA 1280x1024 720p 1280x720 4 5 720p 1024x720 D1 NTSC 720x480 D1 PAL 720x576 4 CIF 704x576 VGA 640x480 2 352x576 CIF 352x288 SIF 352x240 QVGA 320x240 WQVGA 320x180 Rate Control CBR VBR Storage Fixed Frame Video Profile Baseline Main High Fast 15 Frames 30 Frames 60 Frames 120 Frames 240 Frames Video Burst Size 150ms 200ms 300ms 400ms 500ms 1000ms 1200ms 1400ms 1600ms 1800ms 2000ms Video Codec H 264 MPEG 2 Local IP Setup Local IP Address 192 168 X XX Page 11
7. e Open File Cntrl 3 Under the Media Files category choose All Files 4 Choose the SDP file provided by Z3 Technology 5 If the original video is interlaced the video can be deinterlaced as follows a On the Video Menu choose Deinterlace and choose an option other than Disable Page 14 3 Technology 7 0 APPENDIX A SERIAL CONTROL 7 1 Point your browser to http 192 168 3 47 Plug in DB 9 serial cable from Z3 MVE 20 to PC Setup Teraterm on PC for 115k 8 1 1ms char 50ms line Connect to proper COM port Connect the Power of Z3 MVE 20 Power on Z3 MVE 20 Output should come immediately to Teraterm console Terminal Output Set Device Name Set Password Operating Mode Video Source Audio Source Audio Codec Audio Bitrate Video Resolution Rate Control Video Bitrate Video Profile Gop Size Video Burst Size Video Codec Frame Decimation Output Interface Output Format Dest IP Address Dest Port ASI Bitrate ASI PCR Interval PID Audio Video PCR O 1 Local IP Address Local Netmask Default Gateway 1 Stop Load User Settings Save User Settings Load Factory Default settings enter option L xn 23 Technology LLC 23 MVE 20 1 3 1 MVE 20B BLANK 1
8. er you must also use unicast on the VLC receiver If you use multicast on the encoder you must also use multicast on the VLC receiver Power on the Z3 MVE 20 Wait one minute or until LED 1 on the unit lights up Connect the Ethernet cable from the Z3 MVE 20 unit directly to the PC Disable all wireless and local area connections For a client PC to access the Z3 MVE 20 factory default settings set the IP address of the PC to 192 168 x XX Open Firefox or Internet Explorer 8 or above as your web browser Type the IP address of the Z3 MVE 20 in your web browser http 192 168 XX XX and the Z3 MVE 20 Encoder web configuration menu will appear 8 Configure the Z3 MVE 20 with your desired settings See 5 3 Encoder Configuration Options 9 Press Start Encoder on the Encoder Control menu Page 9 Pda ee Tec DE 2 Technology 5 3 IP Settings Encoder Press Stop Encoder on the Encoder Control menu Once the encoder has stopped type in your desired IP settings Hit Save User to save your desired settings Power cycle the Z3 MVE 20 The new IP settings will now take effect 62 Technology prd eem MVE 20 Encoder Firmware version 1 31 UPDATE device name MVE 204 set name set pass logout Operating Mode Encoder Encoder Setup Output Setup l ideo Source Component Output Interface Ethernet Audio Source Analog Jacks Output Format MPEG 2 TS Y Audio Codec AAC
9. erals This system supports H 264 High Profile encode up to 1080p at 30 frames per second The Z3 MVE 20 can be configured as a single channel or dual channel encoder where the latter offers the advantage of low power consumption and lower cost per channel compared to a PC system The Z3 MVE 20 is a cost effective system suitable for broadcast video security satellite uplink remote monitoring and industrial applications The Z3 MVE 20 features multiple I O interfaces such as HD SDI HDMI composite component ASI and Ethernet Multiple interfaces allow customers to quickly integrate full H 264 1080p30 performance into their network without the power consumption and physical space required of a PC based platform 1 2 About the Manual Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use Page 4 3 Technology 2 0 PARTS LIST 2 4 Included Parts cack BNC to RCA Cable x6 AC Cord 2 2 Optional Accessories Serial Cable Ethernet Cable HDMI Cable Page 5 Technology 3 0 FEATURES The Z3 MVE 20 is a dual channel high definition low cost network enabled media encoder with the following features Two identical and completely independent HD encoders Each independent HD encoder supports Resolutions up to 1920x1080 including 1080i 1080p30 and 720p60 H 264 MPEG 4 MPEG 2 video Video and a
10. l respond with Status Changed rate The video stream will continue uninterrupted with the new parameter 9 0 UPDATING FIRMWARE 91 WEB PAGE Locate the UPD z3 mve02 v1 04 00 img file on your Z3 Server user account Save the file on your PC where it can easily be found Follow steps 1 through 7 in section Error Reference source not found On the web menu next to Firmware Version 1 0 4 hit the Update button Hit Browse to find the saved img file on your PC Hit Upload amp Update Power off unit Power cycle system for clean boot and system should be updated 92 SD CARD Locate the UPD z3 mve02 v1 04 00 img file on your Z3 Server user account Place SD card into computer Open the zwriter exe windows program provided by Z3 Select the UPD z3 mve02 v1 04 00 img file Select correct location for your SD card Do NOT make mistake on this item This will cause wherever you are writing to be overwritten There is no recovery once you hit Write Device Eject SD card from computer Place in SD card socket of APP board Power on system with terminal output connected to PC You will see the system updating the flash Once complete the system will boot Power off unit Remove SD card Power cycle system for clean boot and system should be updated 10 0 TROUBLESHOOTING No video is usually caused by networking issues O First check IP address and Netmask Ping PC from Z3 MVE 02 and ping Z3 MVE 02 from PC
11. n Options Output Setup Output Interface SDI Component Composite Video Format Follow Input 1080i 1920x1080 720p 1280x720 Standard Def Video Frame Rate 50Hz 60Hz Page 13 Technology LL 6 0 STREAMING OPERATION After connecting your video audio source and configuring the Z3 MVE 20 Encoder hit Start Encoder so the status below says Status Running If you are using the serial command instead type S to start streaming The way to set up VLC as your streaming receiver on your PC differs depending on the format of your output stream If your output format is transport stream please follow the steps below 6 1 Transport Stream Open VLC Media Player 2 Media menu choose Open Network Stream If using VLC version 1 0 X a On the Protocol menu choose UDP b Type in the static IP address of your personal PC c Change the Port Address to 8888 4 If using VLC version 1 1 X a Enter the network URL as follows udp xxx xxx xxx xxx 8888 where is the IP Address of your personal PC 5 Press play 6 If the original video is interlaced the video can be deinterlaced as follows a On the Video Menu choose Deinterlace and choose an option other than Disable If your output format is real time transport protocol please follow the steps below 6 2 Real Time Transport Protocol 1 Open VLC Media Player 2 On the Media menu choos
12. rameters Note The static IP of the computer cannot be the same as the static IP of the 23 20 Page 8 LLC Go to the Start Menu and select Control Panel Click on Network and Sharing Center Click on View Status Click on Properties Click Internet Protocol TCP IP and click Properties In the Internet Protocol TCP IP Properties window select Use the following IP address if not already selected and specify the IP address you wish to use While entering this data you ll also need to specify the subnet mask and default gateway Internet Protocol TCP IP Properties Microsoft Windows users General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate settings Obtain an IP address automatically 5 Use the following IP address IP address Subnet mask Default gateway Linux users The below information is for how to specify and adjust your network settings through the command prompt Changing your network settings will require root access 9 Use the following DNS server addresses Preferred DNS server Alternate DNS server 1 Getto the command prompt Move to the etc sysconfig network directory Edit the interfaces file and adjust your network settings in this file 5 2 Server Encoder Note If you use unicast on the encod
13. udio decoding Standard Definition encoding for ISDB T DVB H and other standards Video Inputs SD HD SDI HDMI DVI Component Composite VGA Optional ASI input Video input resizer support 1 2 2 3 and 3 4 of standard resolutions Output Interfaces Ethernet ASI Outputs RTP or MPEG 2 Transport Stream USB interface for mass storage devices or other peripherals SD Card interface for local storage and firmware updates 5232 serial port for configuration and control Web based configuration software Page 6 4 0 OPERATING CONTROLS 41 Front View 104 6 4444 Power Switch Status LED s USB Interface SD Card Interface Status LED s USB Interface SD Card Interface 4 2 Rear View 7 Technology Analog Audio Composite In ASI SDI Out SDI ASI In YPbPr In HDMI DVI In VGA In Ethernet Power RS232 Port 9 BJ 9 3 GI 9 5 0 SYSTEM CONNECTIONS The System can be controlled via the web server on the Z3 MVE 20 It can also be controlled via the serial port 51 PC Setup Initially the simplest way to setup the networked PC to communicate with the Z3 MVE 20 is to put the PC on the same subnet as the Z3 MVE 20 The IP address of the Z3 MVE 20 can be found by looking at the bottom side of the Z3 MVE 20 The Windows PC can be setup on the same subnet by using these pa