1. Confirm ogOff Unset Move Select 05 Engineer Set 06 PIN Reset Alarms 07 User User 08 Tel Number Log Full 10 Log Full Late Work 11 Log Cct Bypass 12 Log User Time 13 Log KP 14 Log Date i On a Mini keypad use theW and i 15 Log Alarm i buttons to change the displayed option i 20 Time i Press to choose a menu option toggle i 24 Holiday i an on off option or display list of option 25 5 vmm 26 Group Text 28 Late Work pr 30zBypass H On a standard keypad enter the 2 digit code to select an option 32 Chime I Use th and buttons to change the displayed options 52 Identify User i e the W kI aO 71 Copy User Press to move quickly through the menu 89 Cct Status The menu options shown are for a manager user on a system without access control The actual menu options available to a user will depend on the user authority the system configuration and the current system status Refer to appendix A for details Only 2 options are visible on the display but any available option can be selected by entering the 2 digit code without viewing the actual option number Each menu option is discussed in detail in this manual If no option is selected the user will be automatically logged off after 2 minutes If a chosen option is not available a reason will be displayed Refer to appendix D for details Informat
2. 1718 1788 Turn off output 1 to 8 the selected output must be programmed by the engineer 010 Unset system Oinn Unset group n where n 1 to 32 020 Set system 02nn Set group n where n 1 to 32 03nn Status of set group n where n 1 to 32 Cancel command Note that all commands except toggle are preceded with a before pressing ks Message Length seconds shut down call un and you must wait for the confirm tone Function Main message sent with all speech format alarm reports Channel messages sent when the corresponding channel is active Memo message or stored audio message 41 N oO Me PX QX RX Version 4 20 User Manual Issue B Appendix G System Details Number of Areas Number of keypads Number of Circuits Number of Users Service Number Contract Number Keypads Los EEE EEE 42 PX QX RX Version 4 20 User Manual Issue B Circuits u u Cct 1 Cct 2 3 gt Cct 5 T Cct 8 Cct 10 43 PX QX RX Version 4 20 User Manual Issue B ppc EIL Cct 31 Cct 33 34 Users Description A
3. Each user set group circuit concentrator and access control module can be programmed with a text description 1 Tabel met opmaak ae Verwijderd x gt 1 Verwijderd x gee Verwijderd 8 Verwijderd 16 PX QX RX Version 4 20 User Manual Issue B User Codes Each user of the system is identified by a unique code This code can be a PIN code a magnetic swipe card proximity card or fob A card or fob can only be used on a keypad variant with a proximity interface internal or external The default PIN code for user 2 is 0202 Throughout this manual user codes are only referred to as codes Operator Controls and Displays System Keypads 2 x 16 character LCD backlit display _ Mains indicator _ eeo o9 oo eee Proximity reader target area optional The operator keypad unit incorporates a backlit liquid crystal display LCD comprising 2 lines of 16 characters and a backlit keypad to gain access to the system and to perform all authorised user functions The backlighting will be turned on during the entry time during code entry and while a user is logged on It may also be turned on using any button except v and xand turned off using the or x power indicator This indicator will flash if the system is operating on n standby battery power Mini Keypad 2 x 16 character LCD backlit m display Part Set 1 Part set 2
4. PX QX RX Version 4 20 User Manual Issue B PX QX RX Version 4 20 User Manual Issue B CONTENTS M M 2 O 5 EVENT LOG wD AREAS amp SET GROUPS 529 CIR CUTTS 5 USER GROUP AND CIRCUIT IDENTIFICATION 5 USER CODES see na ER 6 OPERATOR CONTROLS AND DISPLA YS 6 DY STEM KEYPADS orti URS Eee LS POR FN EU de 6 MINI ich d D NE T 6 _ ace 6 DUAL USER CODE OPERATION 5 ees e Ora eee eye eren e Ee eee _4_6 6 __ 7 USER CARD P EN OPERATION o tri heri rie nor Er er EE RODEO TE 7 SETTING FROM A KEYPAD essen en aoo eorr eene eurer eve y eo ene regu ye aee 10 SETTING WITH A MINI KEYPAD ea eerte dro S RR SA 10 KEYSWITCH RADIO KEYFOB SETTING cu rer aer Pv ie ee ved 11 AUTOMATIC SETTING 5 Aborting The Setting Procedure ie ala tee e paire h 11 SETTING WITH WARNINGS vci sittee reco eere eode cie eher tes eieeecaveduaagbvaseeadavedsadbscececseciavsvateysdsned 11 EASY SET nn en nn IRRE 11 SETTING RESTRICTIONS v u reet Everton der eer neo e Vh e e ve YR dre eve ed eee dev eee v veia ege 12 SETTING FAULTS 1
5. At the end of the soak period any circuit which has alarmed is logged as failed Soak Off Circuit nnn Cctnnn circuit has been taken off soak Soak On Brad nnn poc A circuit has been put on soak Software Error software error has been logged 12 Tamper until clear bypassed X On N N channel N on Unset Req user requested unset on a keypad dual unset or unset delay programmed Fail Upload to GSR x failed any An aan he A verified alarm has occurred Watchdog NONE NONE Software watchdog active Appendix Access Log Messages Access Control log only messages Log Text Additional Data Display Text Event Description Access User nn ACM m Usnn User accessed ACM m Card Exit User nn m Usnn ACMm User exit by ACM m which has no door contact Denied User nn Usnn ACMm User denied access ACM m Door Open ACM mm ACM ACM door held open 17 Usnn ACMm User exit by ACM m Unset Req User nn ACM m Usnn ACMm ser request to unset from ACM m 38 PX QX RX Version 4 20 User Manual Issue Appendix E Menu Restrictions If a menu number is entered and the option is not available then a reason will be displayed For example if no area is set and you select unset the panel will prompt with the reason the unset option is not available Not Available This indicates that there is no set area availab
6. PRINT TEXT c 28 PRINT HOES e H 28 IDENTIFY USER M 28 COPY USER Len 29 COPY A USER PX ONLY scscsssssssssssssssssssssscsssssssssssssessssssssssssssssssssssessssssssesssssssscssssesssessssesssssssssessseessessssesssses 29 COT STA d M 29 ACCESS FEATURES ONLY ecsssnssnsnssnsonssnssnssnsnnsnnsnssnnsnsnsnnssnsnnsnnnnnsnssnssnsnnsnnsnnsnnnnnnnsnnsnssnsnnsnnsnnsnnsnnnnne 30 ADD A USER ua a e E E 30 DELETE USER eem M m 31 DOOR UNLOCK sere D 31 DOOR LOCKOUT KERE E 32 32 APPENDIX USER AUTHORITIES crsussossnssnsnnsossnssonsnssnsnnsnnsnnsnnonnsnsnnssnnnnsnnsnnsnnsonsnnsnssnnsnssnsnnsnnsnnsnnsnnne 33 APPENDIX B EDITING TEXT u sussusosssssossnssnssnsnnsnnsnssnnsnssnsnnsnnsnnsnnsnnsnnsnsnnnnnsnnsnnsnnsnnnnnsnnsnssnnsnsnnsnnsnnsnnsnnen 34 APPENDIX LOG MESSAGES cssssssssssscessceccsscescssnssnssssensssscessesseessssssesesssessessessessessessssssssssessesseesesseses 35 APPENDIX C ACCESS LOG MESSAGES ssccsssssssssssssssscssssscssessssesssessssessesessesscssersessessessssessesseeseres 38 APPENDIX MENU RESTRICTIONS ussursossnsonsonsnssonenssnsnnsnnsnnsnnsnnsnnsnssnnnnsnnnnnsnn
7. Print Text Code 40 This option will only be available if a printer is connected to the system The print text option will print all text descriptors Circuit was not shunted Print Hols Code 42 This option will only be available if a printer is connected to the system The print holiday option will print all holiday periods Identify User Code 52 This option allows a user to be identified by presenting the card fob 52 Identify User Present Card Fob User 3 fob presented Unused card fob presented Code Not Used User 20 fob presented 28 PX QX RX Version 4 20 User Manual Issue B Copy User Code 71 71 Copy User Enter the user to copy here r Enter the first and last user To copy a single user enter the same user number as the first and last Copy A User PX Only Code 73 This option will only be available if at least one ACM is fitted to the system Enter the user to copy here Enter the first and last user To copy a single user enter the same user number as the first and last Cct Status Code 89 f When the Status option is selected the circuits that on soak test bypassed isolated or shunted will be scrolled on the display 29 PX QX RX Version 4 20 User Manual Issue B Access Features PX Only The number of ACMs that can be connected depends on the panel varia
8. or printed if a printer is fitted to the system Areas amp Set Groups For protection purposes the premises may be divided into a number of areas Individual areas may be grouped together into a setting group Not RX16i which provides the user with a convenient way of setting and unsetting more than one area at the same time The installation company engineer will have configured your system for the appropriate number of areas and groups to comply with your specific security requirements Where more than one group is incorporated in the system a group can be configured by the installation engineer as a common group A common group will automatically set if all other areas of the system are set and will automatically unset if any one of the other areas is unset The RX16i variant does not include the set group feature If using a RX16i then all references to set groups throughout this manual should be interpreted as areas Circuits Each detector or sensor in the installation is allocated a unique circuit number The installation engineer will have programmed each circuit to respond in a certain way when the circuit is activated when the area is set and unset The way in which the circuit is programmed to respond will depend on the type of circuit and its location and purpose If a circuit is faulty the alarm response may be turned off by an authorised user This process is referred to as bypassing User Set group and Circuit Identification
9. Circuit has failed to activate during the auto check period NONE see note The battery voltage is normal after a battery low NONE see note Battery voltage is low or not present during a battery test NONE see note battery has reached the low volts threshold after a mains fail number Transmitter battery low Th ChangedCode Changed Code nn User mm Usnn Usmm Manager or GSR user changes code for another user Time modified old time and new time are logged Panel fuse number Concentrator fuse Output module fuse fuse Master shunt type circuit clears Circuit alarm has cleared User has chosen a new code which is the same as another user Central station acknowledge alarm report Control panel comm fail input active Central station fails to lacknowledges alarm report User or the panel tested the communicator s Commission Fail Encryption commission fail issi Encryption commission OK call using the Dual comm data route has failed call using the Dual comm data route was successful Date changed manual or auto 35 PX QX RX Version 4 20 User Manual Issue B Det Test Fail or more detector test circuits failed Det Test OK All detector test circuits tested OK respond during a detector test Porm Confirm Dorm Confirm O Download from GSR x failed Bownload OK GSRx D
10. Set PX250HS Only 12 00 Mon 27 Sep in the example the vault area is programmed for dual Guardall i i user set The first user code is 0202 and the second i user code is 1234 Both users must have the authority to set the vault area i Both user actions are logged j 12 00 Mon 27 Sep ella dr A ic chats Enter Logon time limit reached 13 PX QX RX Version 4 20 User Manual Issue B Unset Code 01 The system will have been partitioned by the installation engineer into a number of set groups The user authority will determine the choice of groups which can be unset There are several methods of unsetting available to the user which are discussed in the following section Unsetting can be started by A user request on a keypad A user activating a keyswitch or radio Keyfob Automatically by a timer schedule Remotely from a PC using the Guardall GuardStation software A user request on an ACM Proximity Reader Your installation engineer should advise which of the above options have been programmed your system Unsetting Methods If a set group incorporates an entry route in the unsetting procedure then opening a final entry door to the area will start a pre programmed entry timer The user must proceed directly to the keypad or keyswitch via a pre determined entry route and unset the group as described If the group is not unset before the
11. authority 2 visitor user may only gain access within 10 seconds of an escort user presenting their token 3 supervisor user can access a door with lockout enabled 4 Anescort user can gain access by presenting their token twice within 10 seconds User Menu Schedule Code 6 A user can be programmed with a schedule to control access times Program 00 to allow 24hr access The schedules can be programmed using option 25 22 PX QX RX Version 4 20 User Manual Issue B user Menu Lockout PX Only This option will only be available if at least one ACM is fitted to the system If the lockout option is on for a user then the user code will be ignored until the lockout is turned off User Menu Expiry Date PX Only Code 8 Expiry dates can be programmed for all users panel and access users 4 Authority 5 ACM Authority 6 Schedule 7 Lockout 8 Expiry Date 00000008 Expiry Date Thu 01 Jan 2004 To delete an expiry date enter the day and month of 0000 and the current year The user authority and codes will be removed from the system at midnight on the expiry date Tel Number Code 08 An authorised user can change any telephone number that has been programmed to use the speech format home beep or SMS formats The available formats will depend on the system hardware options A telephone number of up to 16 digits can be programmed This number can include pause digits Pause di
12. during the setting exit period Soak Cct Fails Circuits which have been put on special test by the installation engineer have Unset Alarm unset alarm has occurred the details will then be displayed 40 PX QX RX Version 4 20 User Manual Issue B Appendix F Audio Commands This section only applies to systems that are fitted with an audio bus or speech module The speech and audio functions of the system by using a DTMF telephone handset To use an audio or speech function 1 Dial the control panel telephone number 2 using your PIN code and terminate with the button 3 Enter the required function code after the Code Meaning 32 Activate TalkBack modules 1 to 32 00 Activate all TalkBack modules Toggle between listen and talk modes 59 Replay stored audio the system must be fitted with an audio interface with the speech record option 40 Record main message 415 7498 Record channel messages 1 10 8 Verwijderd 410 Verwijderd 411 Record unset message 4 m 50 Play main message Verwijderd 751 59 Play channel message 1 10 8 Verwijderd 510 Play set message Verwijderd 511 Play unset message 61 68 Turn on output 1 to 8 the selected output must be programmed the Verwijderd engineer
13. entry time has expired a warning period of 30 seconds will be given This is to warn the user that an alarm condition will occur if the group is not unset by the end of the warning period If the group is not unset by the time that the total entry time and warning time has expired an alarm condition will be initiated To comply with the requirements of DD243 2002 during the entry time all alarms in the unsetting area s are ignored Unsetting from a keypad Your installer may have set up your system to allow automatic unset when your user code is entered The diagram shows all 3 possible unset scenarios when a user logs on to a keypad when area s are set 12 00 Mon 27 Sep Guardall Log off after unset programmed 4 Log on unset programmed 12 00 Mon 27 Sep Enter 1 Workshop Workshop 2 Office Unset Log off after unset not programmed Unsetting with Keyswitch or Radio Keyfob To unset an area from a keyswitch turn the keyswitch to the unset position The area under the control of the keyswitch will immediately unset If your system is fitted with a radio interface then a radio Keyfob may be programmed for setting 14 PX QX RX Version 4 20 User Manual Issue B Automatic Unsetting The system may have been programmed by the installation engineer to automatically unset all or parts of the system according to a pre programmed schedule The schedule will
14. gt x gt gt c gt c gt gt x x w w x w wx wx x x x gt gt IS P gt lt gt x x gt gt x gt gt gt gt gt gt gt gt gt gt gt gt lt gt gt x gt gt gt gt w w x gt gt gt gt gt gt x lt gt lt gt x x x gt x gt gt gt gt gt gt gt gt gt Pc gt w gt gt x gt gt gt w w x x x x x x x gt gt gt gt gt gt gt gt x gt gt gt gt x gt gt gt gt gt gt x w gt c gt x w w w gt gt gt gt gt gt x x gt gt gt x x gt gt x gt x gt x w gt x gt x w gt x gt x gt x gt x gt x w w w w w x x x x x x x lt lt gt x x gt gt x x x x w ww x xww xxx x IRIN IR TRIS IS lt w w w xw w w x x x x x w x x x www 1 xx 56 foe IRIS lt lt foe w w x w S gt x gt gt x gt gt x x x x x w w x xww x xx foe IRIN IS lt lt w w x w w gt x 1 The Engineer option is not available to a user if the panel is programmed to allow the engineer to log on without user authorisation 2 The code option for some users will only be available if configured as part of the user authority 3 The time can only be changed by a user if programmed by the engineer User time changes are limited to 75 minutes 4 The bypass option is only available if at least one c
15. timed access The available menu options are dependent on the programmed user authority Refer to the menus options section for details of the menu options available to each authority level Option Description Code Change On Off Some user types are allowed by default to change their own code refer to authority table This feature can be disabled for any user without manager authority LogOnSet On Off If this option is on the system will show a list of set groups that are available to set If only one set group is available setting will start automatically LogOn Unset On Off If this option is on then the authorised set groups which are set will be unset when the user logs on Shunt On Off If this option is on the user has access to the shunt menu option 33 Card PIN On Off If the user is configured with the Card PIN option then BOTH the PIN code and the card must be used to log onto a keypad The PIN code and card may be used in any order This option does not apply when using an access module If Card PIN is off then a user may log onto a keypad using EITHER a PIN code or card Set group 1 max On Off A user can be programmed any combination of set groups 4 Authority 5 ACM Authority 6 Schedule 7 Lockout 02 Ordinary 8 Expiry Date oo 03 Set Uns User nnnn 04 Set Ordinary 05 Unset Code Change Off 06 Cleaner LogOn Set Off 07 Access LogOn Unset Off 10 ATM Shunt Off 11 Log C
16. 2 DUAL SET PX250HS ONLY JNSETTING METHODS Unsetting from a keypad Unsetting with Keyswitch or Radio Keyfob Automatic Unsetting A UNSETTING WARNINGS Re RESTRICTIONS PERMET TM em UNSET DELAY PX250HS ON Yuan en ansehen DUAL UNSET PX250HS ONLY 5 esecececevsesescicssessvceveveseseossevesevvessteestevesuvagesesnweddesevassyejuuedoesswasege jets PX QX RX Version 4 20 User Manual Issue B ACM AUTHORITY PX ONLY anus u N SCHEDULE LOCKOUT PX ONE Yen ee EINE re 23 EXPIRY DAWTETPSCEONPEYVI yy uD Au deb ERE ERR Ere ai 23 TEL NUMBER iscssssccestacossssccssncssesnesscnssasssasscccesssccsecsceuseosscssoessossecdessseceascdcssecedsconessusssscoussuadssseeusecnsassccecesssisceosae 23 POGS 24 dU Up N 24 ION Nm M 25 SCHEDULE PERA E PH 25 GROUP TENT emo 25 MINUTES LEFT PX250HS ONLY cscccsssssssscssssscssssssssscsssssscsscesssscssseessssssescsscesseesesssssssessesssssesessesseeseseases 26 LATE WORK c 26 BYPASS AZ S 27 CHIN 27 Mee RE 28
17. Keypad m Usnn KPm Keypad isolated by user 36 PX QX RX Version 4 20 User Manual Issue B Alarm amp Event Log messages EE Si Ya all Area m Usnn Am Late working has been selected for the area NNNM Fault m sss name Module name Module has reported a line fault Lockout Keypad n Incorrect code attempt limit reached on the keypad Circuit nnn Circuit has alarmed up to the multiple alarm limit Isolate removed from a concentrator A set group was not unset by the schedule close time Panel case or off the wall tamper GSR operator number YY has logged on from GSR number x A PA type circuit alarm Transmitter polling failure Receiver polling fault Supply voltage has fallen to the power fail threshold PSTN Route Fail A call using the Dual comm PSTN route has failed PSTN Route OK A call using the Dual comm PSTN route was successful Item menu description plus optional number see note Cctnnn area has been reset User nn Area m Usnn Usnn area has been reset User nn Keypad m Usnn codes have been restored to default Rmt Auth Fail NONE NONE Repeated attempt to log on bya remote host user requested set ona keypad dual set programmed shunt limit for the system has been reached 37 PX QX RX Version 4 20 User Manual Issue B Alarm amp Event Log messag es circuit on soak test has alarmed
18. ard PIN Off 12 Bank Reset Group 1 Off 14 Guard Group 2 Off Group 32 Off 21 PX QX RX Version 4 20 User Manual Issue B User Menu ACM Authority PX Only Code 5 This option will only be available if at least one ACM is fitted to the system Option Description On Off If this option is off no further user ACM options will be displayed in this menu Normal The access authority of each user can be programmed Visitor Escort or Supervisor ACM 1 On Off A user can be authorised for access through any combination maximum of ACM doors Challenged On Off If a user is programmed as challenged then the ACM door release and open times will be automatically doubled for the user vtinorliuA R 192U 1 E viitorljuA MOA e zov E nO eldena YOlieiVz 3 lt 4 IsrroM Ievo l 4 Toeivisque e 950 8 HO S o HO S ttO bopnollsdd ey Level Access level Help Menu User access right will depend on the programmed user level and the programmed access door mode programmed by the installation engineer There are no restrictions on exit User Access Restrictions User Mode Door Mode Normal Dual Escort Supervisor Normal Visitor Escort Supervisor Notes 1 Dual mode access requires 2 users with either Normal Escort or Supervisor
19. at starts in December and ends in January To achieve this 2 holiday periods must be programmed 24 Holiday Holiday 1 Holiday 1 Start Off Enter DDMM To disable a holiday enter a date of 00 00 The start and end dates must be in chronological order Holidays may be optionally programmed to apply to individual set groups Schedule Code 25 A schedule consists of 4 times for each day of the week and 4 times for days which are holidays A schedule can be used to Auto set and unset parts of the system Control outputs Enable disable keypads Enable disable user access Lock unlock access doors Q i O IS Schedule 1 Mon Schedule 1 Mon Start 1 00 00 Enter HH MM Group Text Code 26 A descriptor of up to 10 characters may be entered for each set group Refer to appendix B for details of how to change a descriptor 25 PX QX RX Version 4 20 User Manual Issue B Minutes Left PX250HS Only Code 27 This option is only available to an ATM user When an ATM user code and a non zero ATM delay period is programmed then a delay prompt will be displayed when the ATM user code is first entered 27 Minutes left 01 ATM 1 f The actual unset menu 02 2 will depend on the ATM user authority and the group descriptors 10 Minutes left Ext Time If the working time is less than 10 minutes and an extension time is programmed then the ATM user may extend the working time If t
20. buttons Alarm LED 8 Set LED 2 30v LED E Proximity reader target area Cards Fobs A user PIN code can be replaced by a card or fob if the keypad is fitted with the optional internal or external reader All Guardall proximity cards and fobs are manufactured with a unique code and duplicate cards or fobs cannot be obtained Spare or replacement cards or fobs can be obtained from the installation company Verwijderd an electronic key Socket or PX QX RX Version 4 20 User Manual Issue B Dual User Code Operation Where a higher level of security is required a keypad may have been programmed to require two user codes to be entered before logging a user on to the system Both user codes must be authorised and are logged by the system The authority of the second user code entered is used by the system The User Card PIN Operation Each user can be programmed with both a PIN and a card If the user Card PIN option is programmed then both codes have to be entered before the user can log on to a keypad Using the System The LCD keypad will normally display the time date and company name If a valid code is entered the user menu will normally be displayed The default manager code is 0202 Enter this code followed by the button to log on 12 00 Mon 27 Sep Guardall 04 Test user token on mini keypad or at power up
21. ge the name user code and authority for any user except the engineer To modify a user s details enter the user number in the range 2 max users In the programming example user 3 is used 4 Authority 5 ACM Authority 6 Schedule The user 2 configuration may only be changed by user 1 or user 2 Access system users can be added quickly using the Add User menu option 50 rather than programming them individually User Menu Name Code 1 When the name option is selected the current user descriptor will be displayed and can be edited Refer to appendix B for details User names can be up to 10 characters long User Menu PIN Code 2 For details of changing a code refer to the main menu code change option The default user codes are shown in the table The maximum PIN code length is 6 digits Default codes 5 Number 3 last user 4 Authority 5 ACM Authority 6 Schedule 7 Lockout 8 Expiry Date 20 1 Verwijderd 4 PX QX RX Version 4 20 User Manual Issue B User Menu Card Code 3 The procedure for adding a card is similar to adding a new PIN Present the new card to reader when prompted to do so Alternatively if the card number is known it can be entered on the keypad The maximum number of card digits excluding the optional site ID is 8 digits User Menu Authority Code 4 Users can be programmed with a number of options including authority level group access and
22. gits can be entered using the button This will be displayed as character Each pause digit represents a 1 second delay Pauses may be required if you are signalling a PABX or if the call is routed through an old exchange Enter a single zero to turn off a telephone number Press Xto delete a single digit 08 Tel Number the number is not used for speech messages Tel Number 1 Not Available No Authority enter the telephone number Tel Number 1 01313333302 An alarm in the home beep format is transmitted as a series of DTMF tones For example if channel 3 was active the transmitted message would be 333 lt 2s gt 333 2s delay gt 3 3 3 2s delay 33 3 2s delay gt 3 Where 3 is the tone pair for digit 3 The channel information is repeated a maximum of 5 times during a call 23 PX QX RX Version 4 20 User Manual Issue B The panel logs all events that occur in the system All events stored in the event log are numbered in the range 0 65535 the event index The event index will be reset to 0 when more than 65535 events have been recorded There are 2 logs the security log and if an ACM s is fitted an access log Each log can be viewed in full or filtered form on a keypad and printed if a printer is connected to the system Options 16 18 will only be displayed if there is at least one ACM on the system Only events for authori
23. have been programmed to take into account the normal opening time non working days and holidays Unsetting Warnings When unsetting from a keypad the user is informed on the display of any warnings e g circuits isolated or on soak The warning display will appear for approximately 4 seconds during the unsetting procedure If more than one warning exists the display will automatically scroll through the list of warnings The unset warnings are 1 Bypassed circuit s the circuit must have 24hr response PIR in Store i 2 Circuit s on soak test has failed a special circuit test mode set up by Isolated the installation engineer so 1 3 Isolated circuit s 4 Line Fault only when setting with telephone line fault is allowed 5 Shunted circuit s 1 6 Circuit has reached the programmed multiple alarm limit 02 Set 7 Battery test faults 04 Test ara Unsetting Restrictions The selected group is programmed with a set level and a higher level set group s has not been unset If a user attempts to unset a high level set group when a lower level is set then a warning message will be displayed In a PX250HS there are several additional conditions that apply when unsetting The keypad must be programmed by the engineer to allow unset The selected group may be programmed for dual user unset An open close schedule may be programmed for the selected group and the time is after the programmed cl
24. he ACM door as locked out for the applied duration 54 Door Lockout An access user with supervisor authority can gain access through a door with lockout enabled Door 1 Door Lockout On ACM Text Code 55 A descriptor of up to 10 characters may be entered for each ACM Refer to the appendix B for details of how to change a descriptor 32 PX QX RX Version 4 20 User Manual Issue B Appendix A User Authorities All user options with the appropriate authority level are shown in the table Menu Option Ordinary Unset Set Reset Test Engineer Code User Tel Number Log Full Log Cct Log User Log KP Log Date Log Alarm A Log Full A Log User A Log ACM Time Holiday Schedule Group Text Minutes Left Late Work Bypass Chime Shunt Print Text Print Hols Add A User Delete User Identify User Door Unlock Door Lockout ACM Text Copy User Copy A User Cct Status SISS AIAN IN IS lt lt lt lt lt lt xxx gt x x gt x gt x gt x x x S S gt gt w gt x o gt x x xww x xxx x ISIS gt gt gt x x gt x gt x gt x gt gt gt gt x gt x w w gt x gt x gt x gt x x x x www xxx x s PH ISIS gt gt gt gt gt x gt x gt x gt gt gt
25. he programmed ATM working time is more than 10 minutes then a warning will be given when the ATM user has 10 minutes working time left and the extend time prompt will be displayed automatically Requests to extend the time will be logged At the end of the working time the ATM user will be automatically logged off and areas that were unset by the ATM user will be automatically set If an ATM user logs off without setting the ATM user authorised areas will be automatically set Late Work Code 28 The late working option will only be displayed if at least one set group is programmed with a schedule and late working has not been already selected When the late working option is selected a list of all available set groups will be displayed The late work time can be any time including times after midnight All late working actions are logged 28 Late Work Late Work Enter HH MM Late Work 00 00 Late Work 19 00 26 PX QX RX Version 4 20 User Manual Issue Bypass Code 30 The bypass option will only be available if a circuit s has been programmed as bypassable by the installation engineer The bypass circuit option allows the user to bypass a circuit that is in a fault condition When bypassed the alarm condition of a circuit is ignored When a circuit is bypassed it is ignored until the bypass is automatically removed when the circuit is next unset or until a user removes the bypass All bypass actions are sto
26. ill only be available if the system is configured for user authorised engineer access This option applies to both local and remote engineer access When the Eng option is selected the system will prompt for the engineer PIN code to be entered 05 Engineer When an engineer logs on to akeypad all other ginee keypads in the system will be inoperable and the Guardall display will show Out of Service or time out 2 minutes 12 00 Mon 27 Sep Guardall Once logged on the engineer working time is limited to 8 hours PIN Code 06 All users on the system are identified by a 4 5 or 6 digit PIN code To change user PIN code log on to the keypad using your current PIN code and choose the PIN option Then follow the display prompts All user PIN code changes are recorded in the system event log If the PIN code option is not available this means that the system has been programmed to prevent you from changing your user PIN code and a new PIN code must be allocated by the security system manager In the example shown the user changes code to 1234 PIN not unique New PIN Not Available If another user on the system already uses the chosen PIN code then that user will be alerted when next logging on to the system The user whose PIN is known must change PIN code to avoid seeing the warning message on every log on 19 PX QX RX Version 4 20 User Manual Issue B User Code 07 Any master user can chan
27. imit reached 04 Test 16 PX QX RX Version 4 20 User Manual Issue B Reset Code 03 The resetting method programmed by the alarm company engineer for each area and the system will depend on the particular security requirements of the area or system There are 3 types of reset 1 Customer reset where the customer can reset any alarm 2 Engineer reset where the alarm company engineer must reset all alarms 3 Managed reset where the customer can reset an alarm after reporting the event to the alarm company Alarm PIR in Office Alarm cannot be reset o t your system is programmed for engineer reset a E t telephone number and code will be displayed Call this number and quote your code if your system is 01 ee configured for managed reset you will be given code Code 123456 to reset your system This code can only be used i If an engineer or managed reset is required it will not 02 Set be possible to set the system 7777 7777 Managed Reset If the system is programmed for managed reset and an engineer reset is required contact the alarm installation company You will be issued with a special 6 digit PIN code This PIN code can be used only once to reset the system Logon to the keypad with this PIN code to clear the engineer reset condition 12 00 Mon 27 Sep Guardall reset code 12 00 Mon 27 Sep Enter kkkkk 17 PX QX RX Versi
28. ion about the system may be displayed when logging on Refer to appendix E for details 1 It is recommended that the manager code is changed from the default as soon as possible Verwijderd 2 minutes Met opmaak Lettertype Arial Engels Groot Brittanni PX QX RX Version 4 20 User Manual Issue B Easy Set If your system is programmed with the easy set option then all PIN codes are 4 digits long and PIN codes can be entered without confirming with the wv button A card or fob may still be used in place of a PIN when easy set is programmed Help When the main user menu is on display press the help button to display information about the system There are 3 options Option Description Assist Select to connect to a remote service operator Your alarm company may not support this feature Contract The customer contract number is a 6 digit number programmed by the installation engineer that uniquely identifies your system Product Info The product info option displays the control panel order code and firmware version number and if fitted the Dialler version number An authorised user can change some of the system parameters When changing an item the help button can be used to display the allowed values Remote Assist Before using the remote assist option you must obtain a number from your alarm company When you need to use the remote service you will be prompted to en
29. ircuit has been programmed to allow bypass The print options are only available of a printer is connected to the system The access options are only available if an ACM is fitted to the system The schedule option is only available if programmed by the engineer no 33 PX QX RX Version 4 20 User Manual Issue B Appendix B Editing Text A number of text descriptors may be changed by an authorised user All changes to descriptors are logged Max Length Default User User xx Set group Group x Access control module ACM x User Number 03 s Smith A M Z When a descrip or is displayed the character being edited will o e be flashing this is shown as a grey character in the diagram i You can change a character using the numeric keys and or alie dd i 9 using umeric key us o i use the V ana buttons to move through the text H save clear move v 9 i character set i User Number 03 Smith ee ee The allowed characters ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijkimnopqrstuvwxyz User 03 8 lt gt 1 _0123456789 A Smith I 34 PX QX RX Version 4 20 User Manual Issue Appendix C Log Messages Anti mask A Circuit program with the anti mask option has alarmed Encryption authentication fail A
30. le to the user No Set Area There are many reasons why an option is not available If you think an option should be available but the prompt is not on display then enter the menu number and the panel will display an appropriate message The following table shows the reasons why a menu option is not available Not Available Message Where Used At Bypass Limit User attempts to bypass a circuit when the number of bypassed circuits is at the programmed bypass limit Call Engineer User attempts to set when an engineer reset is required High Level Set User attempts to unset a lower level group without unset higher levels Isolate Limit User attempts to isolate a circuit when the maximum allowed number of circuits are already isolated Isolated User attempts to bypass a circuit that is isolated Key Not Used The key button which has been pressed is never used in the current menu Keypad Busy User attempts to turn off a keypad that is being used Low Level Unset User attempts to set a higher level group without setting lower levels No Authority User tries to select an option that is not allowed with their programmed authority level No Set Area User selects unset when all areas that can be unset from the keypad are already unset already set Not Programmed The option selected is not programmed Option in Use User selects an option such as test which is in being used by another user Printer Bus User attempts to print and the pri
31. ngs include o i 1 Bypassed circuit s 2 Circuit s on soak test has failed a special circuit test mode set up by the installation engineer 3 Isolated circuit s 4 Line Fault only when setting with telephone line fault is allowed 5 Shunted circuit s 6 Battery test faults when setting is allowed with this type of fault Wa 230v mains faults when setting is allowed with this type of fault Seconds Left 005 Easy Set If easy set mode 1 is programmed then the system will start to part set when you log on During the part set exit time if the exit door circuit is opened and closed the system will full set Pressing the X key during the setting time will cancel setting If easy set mode 2 is programmed then the system can be set without logging on to a keypad Up to 8 parts can be set in this way depends on the control panel type For example to set part 1 of your system from 1 The system can be set by entering 0 tw If using a mini keypad then the house symbol buttons can be used to set 6 D 6 set second group or area firs Iroup or area 11 Met opmaak Subscript f Met opmaak Lettertype Standaard Arial Met opmaak Lettertype Vet Niet Met opmaak Lettertype Vet Niet Met opmaak Lettertype Standaard Arial Niet Superscript Subscript 2 PX QX RX Ve
32. nt The table shows the access features across the panel range Feature ACMs Panel Users Access Users User expiry dates Challenged user option User lock out from keypad ACM Door lock unlock from keypad Programmable unlock time Programmable Aux relay time Anti pass back Access log events Access log real time print Set amp unset SISISISISISIS SISISISISISIS k SISISISISISISISISIS SS SS Note The panel users must be the first users in the system For example on the PX 500 users 2 200 may be access or panel users users 201 1000 can only be access users and user 1 is always the engineer The PX access control system can be configured through a security system keypad or a PC running GuardStation Access Guardall PX proximity cards or fobs may only be introduced to the system through a PX keypad with an integrated proximity reader Add A User Code 50 This option will only be available if at least one ACM is fitted to the system 50 Add A User The user number is automatically incremented when valid card fob is presented rea The user authority is automatically set to Access for all ACM doors and the user text descriptor will be defaulted If required the user authority can be changed using the edit user option 30 PX QX RX Version 4 20 User Manual Issue Delete User Code 51 This option will only be available if at leas
33. nter is in use Shunt Limit User attempts to shunt a circuit when the maximum allowed number of circuits are already shunted System Not Unset User attempts to access an option that is only available when the system is unset for example the event log User attempts to set an area that is being tested on another keypad Test System Circuit check fail has occurred and the user has selected set Timer Control On 39 PX QX RX Version 4 20 User Manual Issue Appendix E Log On Messages When a user logs on the system may display a special message s before the normal menu is displayed The special messages are shown in the table Alarm Abort User logs on within the alarm abort period programmable option You should call the installation company The details will then be displayed The system cannot set the reason s will then be displayed Another user has chosen your code You will then be given the option of immediately changing your code This message will always be displayed on log lon until the code is changed detector in area x has failed an automatic detector test Note that this warning will not be shown if the log on set option applies group s is set and is programmed to automatically unset when a user logs on A circuits has alarmed the maximum number of times allowed programmable The circuit details will then be displayed managed reset code has been accepted User logs on
34. on 4 20 User Manual Issue B Test Code 04 Each area of the system can be tested individually or all areas can be tested at the same time The test time is limited to 1 hour If the user does not end the test by the end of the test time then the panel will exit test mode automatically Enter the area number or 0 to test the system E Not Tested Not fee All Tested Untested circuits will be displayed All circuits tested rei Number 1 Tel Number 2 Please Wait Please n Acknowledge Tested received The panel records all activations from sensors during the unset period When walk test is selected the panel will display all circuits which have not alarmed since the panel was last unset If all circuits are to be tested then select walk test then press the Xbutton and select walk test a second time When the panel exits walk test mode either manually or automatically at the end of the test time then 1 Any fire sensor still in alarm will give a normal alarm response 2 Circuits with a 24 hour response which are still in alarm will be temporarily bypassed 3 Awarning will be displayed if any PA sensor is still in alarm If the comms test is selected then the panel will make a test call to all telephone numbers that have been programmed for test by the installation engineer 18 PX QX RX Version 4 20 User Manual Issue B Engineer Code 05 The Eng option w
35. ose time This condition may be ignored following an alarm in one of the set group areas if the set group is programmed with an alarm unset time In this case after unsetting the set group will automatically set after the programmed Alarm Unset period 4 The selected group may be programmed with an Unset Delay time and set group will only unset at the end of the programmed unset delay period A message will be displayed during this time and the user unset request will be logged 5 If a group is manually set before the scheduled set time then it may be unset up to the number of programmed Early Set minutes after the time the group was set 6 The schedule unset option does not apply Met opmaak opsommingstekens en nummering 15 PX QX RX Version 4 20 User Manual Issue B Unset Delay PX250HS Only 12 00 Mon 27 Sep Guardall O00000 12 00 Mon 27 Sep Enter In the example the vault area is programmed with an unset delay The unset delay time is programmed by the installation engineer Log off after unset programmed i In the example the vault area is programmed for dual 1 user unset The first user code is 0202 and the second i user code is 1234 Both users must have the authority to unset the vault area B i Both user actions are logged in the event log 12 00 Mon 27 Sep Guardall 12 00 Mon 27 Sep Enter 01 Unset O4 Test Logon time l
36. ownload from GSR x OK SIT Reset WT nnn Engineer reset type circuit alarms area is not unset before the end of the entry warning period Entry circuit opens Config change User expiry date change ATM user selected a time extension User nn Area m Event programmer failed to auto set due to circuits in alarm Radio module number RM nn Radio Module fault no response when unset The system fault response option must be programmed This option is only available in EN50131 compliant variants Faut IGireuitnnn Octnnn Circuit short circuit when unset Faut _____ Failed poll when unset Fault OPM nn nn Failed poll when unset Fault A CM nn ACM nn Failed poll when unset A fire type circuit alarm Fire door open when unset User entered code on Dual code keypad GSM Route Fail A call using the Dual comm IGSM route has failed GSM Route OK A call using the Dual comm IGSM route was successful 258 number x polling restarted A call from an unauthorised IGSR was rejected by the panel the serial number was not Number of activations of all circuits programmed with the head count option while the panel was unset Maximum PIN attempts reached The isolate limit for the system has been reached Isolate User nn Circuit mmm snn Cctmmm Circuit isolated by user Isolate User nn Concm Usnn m Concentrator isolated by user Isolate User nn
37. reas 1 2 3 4 2 j C 44 Guardall Limited Lochend Industrial Estate Newbridge Edinburgh EH28 8PL Tel 0131 333 2900 FAX 0131 333 4919 Technical Hotline 0131 333 3802 Part Number 320995 0B
38. red in the event log A bypass limit will have been programmed by the installation engineer to limit the number of circuits that can be bypassed at any one time The system will display an error message if you try to exceed this limit 30 Bypass Joo circuit Number _ Limit 1 to max Ente it voee Max Number of Ci t hi 24h not bypassed y be bypassed Y bypassed bypassed already bypassed area Cct 01 Not Available Cct 01 Cct 01 Cct 01 Cct 01 Bypassed No Authority Normal Normal Active Set Not Available At Bypass Limit Chime Code 32 Certain circuit types can be selected as chime circuits when unset To select the chime function for a circuit enter the circuit number In the example chime is turned on for circuit 1 32 Chime 9 Press any button Circuit 1 Chime Off Circuit 1 Chime On 27 PX QX RX Version 4 20 User Manual Issue Shunt Code 33 A manager or ordinary user can be programmed with the shunt option The shunt option will only be displayed if there are shuntable circuits in the user authorised areas Shunted circuits may be viewed at any time using option 89 Cct Status All shunt actions are logged Enter circuit number Max Number of Circuit cannot Circuit was circuits already be shunted shunted shunted Not Available Cct 01 Not Available Not Programmed Shunt Off Shunt Limit
39. rsion 4 20 User Manual Issue B Setting Restrictions 1 The selected group is programmed with a set level and a lower level set group s has not been lt Met opmaak set opsommingstekens en 2 If a user attempts to set a high level set group when a lower level is not set then a warning nummering message will be displayed In a PX250HS there are several additional conditions that apply when setting 1 The keypad may be programmed to disable setting 2 The selected group may be programmed for dual user set Setting Faults If the group cannot set a message will be displayed This can occur at the start of setting or at the end of the exit time depending on how your system is set up and when the fault occurs If a fault occurs during the exit time the exit tone will change to a warning tone The external sounder may also have been programmed by the installation engineer to activate in the event of a failure to set 1 Workshop 2 Office Cannot Set Cct Fault PIR in Hall Set After the setting fault s is displayed the force set option may be presented if programmed by the installation engineer The force set option will attempt to automatically bypass all faults The circuit s with i the fault must be programmed by the engineer to allow PIR in Hall bypass Bypassed Workshop Seconds Left 005 12 PX QX RX Version 4 20 User Manual Issue B Dual
40. sed areas and access doors will be displayed or printed 10 Log Full 1 Display PIR in 11 Log Cct oo 2 Print Bypassed 00071 Filter Date Enter DDMMYYYY Use the button to change the e Door display view of an event and the buttons to change the event being i 3 00001 Mon 07 Apr 2003 00 00 02 User 2 Mr 4 Logged KP 0 A Event index Event date Event time Event details Refer to the appendix C for details of all log messages Some users have the authority to change the time by up to 75 minutes from the time set by the engineer if the user clock edit option is programmed Time changes are recorded in the event log Change greater than 75 minutes Out of Range 24 displayed When an event is printed all the event data is printed Circuit Number 13 Log KP ES 14 Log Date 12 00 00 Cct1 15 Log Alarm Bypassed 16 A Log Full 17 A Log User K 18 A Log Door o6 Tea Fri 3 Jan 2003 PX QX RX Version 4 20 User Manual Issue Holiday Code 24 The programmed holidays are used in conjunction with the programmable schedules The holiday date format is day and month only No year is entered therefore the entered date will remain programmed as a holiday for all years or until it is removed from the holiday schedule It is not possible to program a holiday period th
41. snssnnsnssnsnnsnnsnnsnnsnnsnnsnnne 39 PX QX RX Version 4 20 User Manual Issue B PX QX RX Version 4 20 User Manual Issue B Introduction The PX Electronic Intruder Alarm System is designed to provide secure protection for the installation The system comprises a main control panel normally located out of sight in a secure area and at least one keypad The panel has a wide range of features which are programmed by the engineer on installation to suit the security requirements of the particular installation Some of the features may be reprogrammed edited or viewed as required by an authorised user Feature RX16i QX32i PX80i r Panel Users Max Access Users Areas Set Groups Sub systems Max Keypads Access Modules Audio Modules Radio Modules Max Transmitters Tel Numbers Schedules Holidays Event Log Size Access Log Size x gt x x gt gt fis to co gt 103 4 n2 gt o Event Log The event log will record all events for example user log on times and user numbers keypad numbers setting and unsetting times alterations made to programmed settings fault conditions etc When the event log is full the oldest event will be automatically removed when the next event occurs All log events are date and time stamped and may be viewed
42. ss will determine which set groups are available to a user Setting can be started by A user request on a keypad A user activating a keyswitch or radio Keyfob Automatically by a timer schedule Remotely from a PC using the Guardall GuardStation software A user request on an ACM Proximity Reader m RON Setting modes include 1 Instant where setting is completed immediately 2 Timed where setting is completed at the end of the programmed exit time 3 Exit point where setting is completed by opening and closing the final exit circuit 4 Push button where setting is completed by pushing the external PB circuits after opening and closing the final exit circuit Your installation engineer should advise which of the above options have been programmed on your system Setting from a keypad 12 00 Mon 27 Sep Guardall Log on set programmed one group available 12 00 Mon 27 Sep and no problems or warnings to display Enter Log on set programmed 1 Workshop 2 Office Log off after set programmed Workshop Setting Workshop Seconds Left 005 Exit time expired Log off after set not programmed Workshop Set Setting with a Mini Keypad The mini keypad has two quick set buttons The actual areas or groups controlled by the green and yellow buttons will depend on how the system has been 10 Met opmaak Lettertype Arial Engels Groot Bri
43. t one ACM is fitted to the system In the example shown user 3 is deleted from the system 51 Delete Users f Enter the range of users to delete To delete a single user enter the user number twice User numbers can be entered without leading zeros Delete Users fe ee Door Unlock Code 53 This option will only be available if at least one ACM is fitted to the system An ACM door can be manually locked unlocked from a keypad An optional unlock time of up to 255 minutes can be programmed If a time of zero is programmed the door will remain unlocked until the unlock option is turned off While a door is locked it can still be opened by presenting a valid user card The system can be programmed by the engineer to allow the manual door lock unlock option to override the schedule control N i 31 PX QX RX Version 4 20 User Manual Issue B Door Lockout Code 54 This option will only be available if at least one ACM is fitted to the system The locked out ACM door will remain locked and will refuse all access attempts until the lockout is removed The ACM door lockout can only be removed through this programming option The ACM door lockout will over ride any user ACM schedule permissions or otherwise immediately and for the applied duration Upon removal the ACM door will be returned to its previous state if that state still applies Proximity reader LED s will show t
44. ter this number and the panel will dial the alarm company The alarm company will then be able to check the condition of your system and identify and resolve problems f You will now be logged off and the system will now connect to the remote service centre Service not available on entered number 12 00 Mon 27 Sep Guardall PX QX RX Version 4 20 User Manual Issue B Incorrect Codes If Easy Set is not programmed and an incorrect user code is entered the incorrect code message will be displayed for a few seconds or until another key is pressed The installation engineer will have programmed a limit on the number of incorrect code attempts that can be made If more than the programmed number of code attempts are made to enter a valid user code the keypad will be locked out and the display will show Out of Service for a period of 5 minutes Any attempt to enter a user code during the locked out period will extend the period by another 5 minutes 12 00 Mon 27 Sep Guardall 5 Min Delay 12 00 Mon 27 Sep Enter Maximum Code attempts 12 00 Mon 27 Sep Out Of Service 12 00 Mon 27 Sep Incorrect Code PX QX RX Version 4 20 User Manual Issue B Set Code 02 The system can be partitioned into a number of parts called set groups each of which can be individually set The programmed user authority level must allow setting and the programmed user area acce
45. ttanni Met Subscript Met opmaak Lettertype Standaard Arial Niet Superscript Subscript PX QX RX Version 4 20 User Manual Issue B Keyswitch Radio Keyfob Setting As an alternative to setting and unsetting from a keypad your system may be fitted with an optional keyswitch which permits setting and unsetting of a group by operating a keyswitch The keyswitch may be configured for any set mode If your system is fitted with a radio interface then a radio Keyfob may be programmed for setting Automatic Setting The system may have been programmed by the installation engineer to automatically set all or parts of the system according to a pre programmed schedule The schedule will have been programmed to take into account the normal closing time non working days and holidays The schedule may be configured for any set mode Aborting The Setting Procedure The setting procedure can be aborted at any time during the exit time by pressing Xon the keypad that was used to start setting logging on to any other keypad turning a keyswitch to the unset position or an appropriate radio Keyfob Setting with Warnings The system will automatically display any conditions that the user should be aware of before setting the system These conditions are described as set warnings and do not prohibit the user from setting the system in the normal way 1 Workshop 2 Office o f The set warni