Home
Infinity Orange User Manual
Contents
1. 25 Figure 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 Should any of these alarms or indications continue after troubleshooting contact your healthcare provider for pump service 19 Copyright 2008 ZEVEX Incorporated Figure 3 1 501 ER99 Alarm Figure 3 2 LOAD SET Alarm TU LLIW PATI Figure 3 3 LOW BATT Alarm 3 ALARMS MESSAGES AND INDICATIONS Alarms ERO1 ER99 Figure 3 1 Pump will sound a continuous beep and display will read ER followed by a two digit number to indicate a self test has failed To clear alarm Turn the pump off and then back on WARNING If an error occurs ER01 ER99 will ap pear in display all settings and volume counters should be checked and verified before starting a feed ing LOAD SET Figure 3 2 Pump will sound a dual tone beep repeatedly and display will read LOAD SET Why This alarm will sound when pump attempted to run with the set improperly loaded or missing To correct the problem Press the RUN PAUSE key to silence alarm and place pump in pause mode then check the following 1 An Infinity brand disposable set is loaded into pump properly and door is closed 2 Check cassette receptacle for cleanliness es pecially around pressure sensors If cleaning is necessary refer to CHAPTER 5 CLEANING Page 29 LOW BATT Figure 3 3 When 1 hour or less of battery life is available display will flash
2. Step 1 Prepare the disposable set with enteral feeding solution as described in the Prim ing and Loading the Disposable Set instructions Page 7 Step 2 Hang feeding bag or container so that the bottom of bag is at or above the level of the pump door OR If an Infinity brand carry pack is to be used load pump and feeding bag into the proper compartments securing pump bag and tubing with the pack s straps Page 31 Step 3 Turn pump on by pressing the ON OFF key After running the self test display will show last programmed rate LETT PEN S Step 4 RATE Eur Figure 2 11 Program Rate to 100 ml hr r1 DD DOSE EIF E Figure 2 12 Program Dose to 50 ml Press the or key to change the rate to 100 ml hr Hold down either key to change rapidly Figure 2 11 Step 5 Press the RATE DOSE key to display dose Press the Or key until a dose of 50 ml is displayed Figure 2 12 Infinity Orange Operator s Manual 10 2 DIRECTIONS FOR USE Step 6 Confirm food type to be delivered formula or human milk before starting pump by pressing the FOOD TYPE key Press the or key to change between formula and human milk Step 7 Connect barbed adapter to the patient s enteral feeding tube Step 8 Press the RUN PAUSE key Pump will begin run LETT ning Display will show programmed rate and the arcs LIL around the run symbol will rotate Figure 2 13 mir
3. ZEVEX Enteral Nutrition Delivery Systems MERICA S HEALTE MOOG Addendum to EnteraLite Infinity Operator s Manual Part Number 25356 001 Revisions thru H Use ONLY commercially available pre packed or commercially prepared feeding solutions formulated for use with a feeding pump that are prescribed by a licensed health care provider dietician or nutritionist DO NOT USE HOMEMADE BLENDERIZED OR LIQUIDIZED FOODS OR OTHER NON PRESCRIBED NON COMMERCIALLY AVAILABLE FEEDING SOLUTIONS Use of homemade blenderized or liquidized foods or other non prescribed feeding solutions may cause sticky solids which could cause an obstruction of the optical sensor It is recommended that all users clean and maintain the pump and optical sensors according to manufacturer s recommendations The Infinite Dose or Interval Feeding programming option listed in the operator s manual should NOT be used for seriously health compromised patients and children or patients who are extremely sensitive to receiving air in the stomach with an enteral feeding It is recommended that a single feeding regimen for specific dose be used for this particular user group 52498 RevA MOOG Addendum to EnteraLite Infinity Operator s Manual Part Number 25356 001 Revisions A thru G Seriously health compromised users and children or users who are extremely sensitive to receiving air with an enteral feeding should not use the Infini
4. 0 3 inches 415 24 cm 0 76 cm with respect to center of rotor NOTE For rates less than 1 ml hr place pump level with patient NOTE Head height effect on accuracy is shown below Figure 8 1 2 5 1 1412 in 2 596 Figure 8 1 Head Height Effect on Accuracy If these specifications meet the required feed regimen Infinity Orange can be used to deliver enteral formulas to pediatric patients ALWAYS VERIFY RATE DOSE AND FOOD TYPE BEFORE PROCEEDING TO FEED 35 Copyright 2008 ZEVEX Incorporated 9 ADDITIONAL TECHNICAL INFORMATION ADDITIONAL TECHNICAL INFORMATION Electromagnetic Emissions Interference Electromagnetic emissions may affect the operation of any electronic medical de vice including enteral feeding pumps The Infinity Orange will not be affected by electromagnetic emissions in most environments However some electromagnetic fields produced by personal com munication equipment household appliances or occupational tools may cause electromagnetic interference EMI which can affect the pump Possible sources of electromagnetic interference with electronic medical devices include but are not limited to cellular phones cordless telephones microwave ovens anti theft security systems blenders and high powered tools i e drills saws chain saws If electromagnetic emitting devices are operated within one yard meter of the Infinity Orange the pump may automatically shut off an
5. DOSE Step 1 With pump turned off press and hold for 1 5 seconds the and the ON OFF keys at the same time Pump will beep and then display the words BEEP HIGH or BEEP LOW Press the key to change to HIGH or the key to change to LOW Pump will give a triple beep when the or keys are pressed and setting will change If setting is as desired do not press either key Step 2 Press the PRIME key Display will read UNLK unlocked or LOCK locked Press the key to change to LOCK locked or the key to change to UNLK unlocked If setting is as desired do not press either key 17 Copyright 2008 ZEVEX Incorporated 2 DIRECTIONS FOR USE Step 3 Press the PRIME key again Display will read MUTE WHEN DONE or BEEP WHEN DONE Press the key to change to BEEP WHEN DONE or the key to change to MUTE WHEN DONE If setting is as desired do not press either key Step 4 Press the PRIME key again Display will read LITE ON or LITE OFF Press the key to change to LITE ON or the key to change to LITE OFF If setting is as desired do not press either key Step 5 Press the PRIME key again Display will read MAX RATE followed by NONE or a maximum rate value such as 100 ml hr Press the or key to scroll between settings until the desired value is displayed If setting is as desired do not press either key Step 6 Press the PRIME key again Display will read MAX DOSE followed by NONE or a maximu
6. To correct the problem View rate dose and food type Change settings where required by using the or key NOTE The food type key allows users to select whether they are delivering formula when select ed screen will read FORM ULA or human milk screen will read HUMN MILK The pump auto matically calibrates the air in line sensor sensitivity based on what food type setting is chosen Infinity Orange Operator s Manual 24 3 ALARMS MESSAGES AND INDICATIONS Battery Doesn t Hold Its Charge Battery will lose its charge if stored for a long period of time or if stored at high temperatures such as in an automobile during summer To correct the problem Recharge the battery If the problem continues during regular use contact your healthcare provider for service Battery Doesn t Charge If the battery symbol and the E and F of the fuel gauge Figure 3 13 are flashing while the pump is plugged in the battery is not charging EIINF To correct the problem Contact your healthcare Figure 3 13 Battery Symbol provider for service and the E and F of the Fuel Gauge Charger Installed but No Plug Symbol Visible If the plug symbol does not display after the AC Adapter Charger is plugged into pump and a live power outlet then charger is not charging battery To correct the problem Check the following gt Verify that the wall outlet works by plugging in another
7. appliance such as a lamp Charger is connected properly If this does not correct the problem pump or charger may be damaged Contact your healthcare provider for service NOTE There are no user serviceable or replaceable components inside the Infin ity Orange 25 Copyright 2008 ZEVEX Incorporated 4 TROUBLESHOOTING GUIDE TROUBLESHOOTING GUIDE NO FOOD Alarm If re priming of the pump delivery set is required it is advisable to disconnect the enteral adapter from the patient s feeding tube while re priming 1 Is feeding bag empty Refill bag re prime delivery set and resume feeding 2 Is air present in the tubing Has all air been removed from bag of pump delivery set v IF YES Press and IF NO Manually prime tubing by hold the PRIME key turning bag upside down gently to move air in the squeezing lower half of bag while tubing past pump pinching the orange colored tubing delivery set cassette just below the drop symbol Hold and resume feeding this position until all air is removed from bag and tubing Let formula sit for 10 15 minutes before preparing pump delivery set for feeding If foam is present in tubing flush by priming pump delivery set either manually or with the pump and resume feeding 3 Is formula blender ized or aggresively mixed Remove tubing from pump and manually prime tubing by turning bag upside down gently squeezing lowe
8. device into outlet to verify outlet is function ing properly 2 Is wall outlet function ing properly 3 Does the charger adapter appear to have any damage Contact your healthcare provider or ZEVEX Customer Service at 800 970 2337 to receive a new charger 4 Does the charger port appear to have any damage including bent or missing pins Contact your healthcare provider or ZEVEX Customer Service at 800 970 2337 to return pump for service Contact your healthcare provider orm ZEVEX Customer Service at 800 970 2337 to return pump 5 Is Battery Symbol and USED E and F of fuel gauge ing flashing If condition continues contact your healthcare provider or ZEVEX Customer Service at 800 970 2337 to return pump for service Infinity Orange Operator s Manual 28 5 CLEANING CLEANING WARNING To avoid electrical shock never clean pump or Infinity Orange AC Adapter Charger with charger plugged into an outlet or pump turned on WARNING Make sure the Infinity Orange AC Adapter Charger is completely dry before plugging into an electrical outlet To clean the Infinity Orange enteral feeding pump Pump may be cleaned with warm soapy water standard dish soap and a non abrasive sponge or 508 cloth Use a cotton swab to clean pathways of cassette receptacle and to remove orange silicon residue from pump wheel roller pins OR Apply one of the following solutions for ap p
9. fuel gauge of the battery Each block represents approximately 6 hours of charge When each bar is half spent it will begin to flash indicating approximately 3 hours of charge is left for that bar When the last block is gone the battery symbol will blink to indicate there is approximately 30 minutes of charge left Display will flash LOW BATT every 3 seconds and pump will beep every 2 seconds to remind user of low battery condi tion When battery is fully depleted pump will turn off automatically NOTE The battery life is an approximation based on a fully charged battery and a flow rate of 125 ml hr Higher flow rates will run the battery down faster while lower flow rates will allow the battery to last longer Battery life degrades over time Infinity Orange Operator s Manual 14 2 DIRECTIONS FOR USE EM F ENT F ENNIF e Figure 2 18 Fuel Gauge Copyright 2008 ZEVEX Incorporated The Battery Charging the Battery To charge the battery insert plug from AC Adapter Charger into port on the left side of pump Plug charger into a wall outlet Pump will charge whether it is turned off or running When charger is plugged in and charging the plug symbol will appear in the display and the fuel gauge will display four bars scrolling from E to F This pattern continuously repeats while pump is charging Figures 2 18a through 2 18e When bars stop scrolling pump is done charging To check the stat
10. primed Approximately 3 5 ml of air is drawn into the tubing before the enteral pump detects bag is empty Therefore approximately 2 5 ml of fluid remains in the disposable set when pump stops feeding Routine Maintenance There are no user serviceable parts or routine calibration or adjustment procedures required for Infinity Orange All service requests should be referred to ZEVEX tech nical service 37 Copyright 2008 ZEVEX Incorporated 10 WARRANTY WARRANTY Solely for the benefit of the original buyer ZEVEX INCORPORATED ZEVEX warrants all new Infinity Orange products of its manufacture to be free from defects in material and workmanship and will replace or repair F O B at its factory in Salt Lake City Utah or other location designated by ZEVEX any Infinity Orange products returned to it within twenty four 24 months of original purchase by the buyer Such repair or replacement shall be free of charge ZEVEX warrants to the original buyer all repaired or replaced products to be free from defects in material and workmanship and will replace or repair such prod ucts F O B at its factory in Salt Lake City Utah or other location designated by ZEVEX Such repair or replacement shall carry a warranty of ninety 90 days from the date of repair or replacement or the balance of the new product warranty as described above whichever is greater This Warranty applies to all Infinity Orange products manufactured b
11. then feeds through a port at bottom of pack either side Also included in this pack is a pocket that may be used to hold an ice pack Dimensions 13 H x 8 W x 4 5 D Approximate weight when loaded with pump and 500 ml delivery set filled with 500 ml of water 2 9 Ibs 1200 ml delivery set filled with 1200 ml of water 4 5 Ibs Ice Pack Pocket Feeding Bag Strap 500 ml Bag Compartment Tubing Strap Pump Compartment Tubing Strap 1200 ml Bag Compartment Figure 6 4 Mini Figure 6 5 Mini Backpack Cutaway Figure 6 6 Mini Backpack Cutaway Backpack View of Internal Compartments View of Internal Straps Infinity Brand Super Mini Backpack Order Numbers PCK2001 black PCK2002 light green and gray PCK2003 Specialty Pack call for current colors Pack holds Infinity pump with a 100 ml or 500 ml bag Pump is secured with a Velcro strap A Velcro strap secures the neck of the bag The tubing is loaded into pump and any excess length of tubing can be secured with a Velcro tab The downstream tubing then feeds through a port at bottom of pack either side Dimensions 9 5 H x 8 W x 4 D Approximate weight when loaded with pump and 500 ml delivery set filled with 500 ml of water 2 3 Ibs Feeding 500 ml Bag Compartment Tubing Strap Pump Location Pump Strap Figure 6 7 Super Mini Figure 6 8 Super Mini Backpack Figure 6 9 Super Mini Backpack B
12. 17 Max Rate 16 Settings Lock 16 V VOL TOTAL Key 3 11 W Waist Pack 32 Water 29 46 NOTES Infinity Orange Operator s Manual 2008 ZEVEX Incorporated Mac ore of the follow atent
13. 2 SHUT DOOR 23 Alarm Volume 16 Backpack 32 Battery 14 AC Adapter Charger 15 Battery Life 14 Battery Symbol 14 Charge Time 14 Charging the Battery 15 Fuel Gauge 14 LOW BATT Alarm 14 Maintenance 7 Messages 3 DOSE DONE 12 23 Mini Backpack 31 0 Occlusion Blockage 1 ON OFF Key 3 Operating Orientation 33 P Pole Clamp 2 7 30 Prime Feature 3 8 9 24 PRIME Key 3 9 24 Program Memory 11 33 R Rate 10 33 RATE DOSE Key 3 Rinse 29 RUN PAUSE Key 3 S Self Test 9 Serial Number 9 Settings Lock 16 Single Feeding Example 10 Size Pump Specifications 33 Software Revision 9 Super Mini Backpack 31 Symbols 5 INDEX 5 Electromagnetic Emissions Interference 36 Error ER01 ER99 20 F Feeding Completion 12 Feeding Example Single Feeding 10 Flow Rate 10 33 35 Foam 7 22 Food Type 3 11 24 26 Fuel Gauge 4 15 Indications Battery Doesn t Charge 25 Battery Doesn t Hold Its Charge 25 Charger Installed but No Plug Symbol Visible 25 CON FIRM DOSE AND FOOD TYPE 24 MAX 24 TO STOP LET GO 9 Instructions for Use Removing Air 7 K Keypad Key 3 Key 3 CLEAR Key 3 FOOD TYPE Key 3 ON OFF Key 3 PRIME Key 3 RATE DOSE Key 3 RUN PAUSE Key 3 VOL TOTAL Key 3 Infinity Orange Operator s Manual INDEX Copyright 2008 ZEVEX Incorporated 45 U User Preference Settings 16 Adjusting User Preference Settings 17 Alarm Volume 16 Backlight 16 Dose Done 16 Max Dose
14. 6 To silence alarm when the dose is complete press and hold the ON OFF key for 1 5 seconds to turn pump off or press the RUN PAUSE key to put pump in pause mode Infinity Orange Operator s Manual 12 2 DIRECTIONS FOR USE Next Feeding Turn pump on Previous settings for rate and dose will be saved in memory Con firm that rate dose and food type are correct by viewing each parameter making necessary adjustments and restarting the pump with a new feeding NOTE If pump is turned off and turned back on again the volume delivered coun ter resets to 0 and food type resets to formula Rate dose and food type must be confirmed before restarting the pump with a new feeding If dose and food type are not viewed prior to pressing the RUN PAUSE key pump will alarm and display CON FIRM DOSE AND FOOD TYPE NOTE Rate dose and food type settings can be locked so that changes cannot be made See the User Preference Settings section Page 16 for instructions to change these settings 13 Copyright 2008 ZEVEX Incorporated 2 DIRECTIONS FOR USE The Battery Running on Battery Power Infinity Orange will run for 24 hours at a rate of 125 ml hr A fully depleted battery takes ap proximately 6 hours to fully charge When pump is running on battery power the ELLE battery symbol will appear in the display Fig ure 2 17 Figure 2 17 Battery Power Indicator The segments or blocks between E and F represent the
15. 70 2337 to receive a new door 3 Is pressure sensor region of cassette receptacle clean Clean pressure sensor area with a cotton swab soft cloth or dampened sponge or wash entire pump under running water Do not use abrasive materials or harsh chemicals Contact your healthcare provider or ZEVEX Customer Service at 800 970 2337 to return pump for service 4 Are there visible signs of damage to pressure sensors Disconnect from patient and fill a new delivery set with food area Prime set and start pump If alarm continues contact your healthcare provider or ZEVEX Customer Service at 800 970 2337 for assistance 27 Copyright 2008 ZEVEX Incorporated 4 TROUBLESHOOTING GUIDE 501 ERO2 or ER03 Alarms Turn pump off Unload and reload delivery set cassette 1 Was pump door open Make sure door is closed securely then turn pump back on while pump was turned on or while 4 If alarm continues contact your healthcare running provider or ZEVEX Customer Service at 800 970 2337 for assistance Charging Problems Check connections for both wall plug and pump adapter Green indicator light on charger wall plug should be illu minated and pump display should have plug symbol with scrolling bars between E and F of fuel gauge When pump is fully charged bars will stop scrolling 1 Is A C adapter charger plugged into wall outlet and pump properly Plug another
16. FF key to turn pump off or press the RUN PAUSE key to put pump in pause mode before starting another feeding TI Figure 9 DOSE DONE Message 23 Copyright 2008 ZEVEX Incorporated Figure 3 10 Priming Indication METwV ITA Figure 3 11 MAX Indication En Figure 3 12 CON FIRM DOSE AND FOOD TYPE Indication 3 ALARMS MESSAGES AND INDICATIONS Indications TO STOP LET GO Figure 3 10 When pressing and holding the PRIME key alarm will sound once pump will begin pumping at maximum rate of 480 ml hr and display will read TO STOP LET GO To stop priming Release the PRIME key MAX Figure 3 11 If a rate dose limit has been programmed in the User Preference Settings pressing the key when that limit has been met will cause the pump to display MAX For example if the User Preference Setting for maxi mum rate has been programmed to 100 ml hr when the user attempts to program a rate higher than 100 ml hr the rate will stop increasing and each time the key is pressed the display will read MAX When re leased display will read 100 ml hr To correct the problem Change limit in User Pref erence Settings Page 16 CON FIRM DOSE AND FOOD TYPE Figure 3 12 All feeding parameters must be confirmed before pump will begin running This message will display if the RUN PAUSE key is pressed prior to viewing rate dose and food type parameters
17. LOW BATT every 3 seconds and pump will beep every 2 seconds to indicate battery is low and pump will soon stop running To correct the problem Plug in AC Adapter Char ger to recharge battery Infinity Orange Operator s Manual 20 3 ALARMS MESSAGES AND INDICATIONS FLOW IN Figure 3 4 Pump will sound a dual tone beep repeatedly and display will read NO FLOW IN j Why This alarm has occurred because pump has de tected blockage in the set between pump and bag To correct the problem Press the RUN PAUSE FH key to silence alarm and place pump in pause mode then check the following 1 Check tubing for kinks or formula clumps Cor T rect blockage 2 Check cassette receptacle for cleanliness es pecially around the pressure sensors If cleaning Figure 3 4 is necessary refer to CHAPTER 5 CLEANING NO FLOW IN Alarm Page 29 NO FLOW OUT Figure 3 5 Pump will sound a dual tone beep repeatedly and N Il display will read NO FLOW OUT Why This alarm has occurred because pump has detected a blockage in the set between pump and patient To correct the problem Press the RUN PAUSE J key to silence alarm and place pump in pause mode then check the following ni m 1 Check tubing for kinks or blockages Remove LILI kink or blockage 2 Check cassette receptacle for cleanliness es Figure 3 5 pecially around pressure sensors If cleaning is NO F
18. LOW OUT Alarm necessary refer to CHAPTER 5 CLEANING Page 29 3 Back pressure from patient may also cause this alarm Discuss with physician 21 Copyright 2008 ZEVEX Incorporated 3 ALARMS MESSAGES AND INDICATIONS NO FOOD Figure 3 6 Pump will sound a dual tone beep repeatedly and N display will read NO FOOD J ML Why This alarm has occurred because pump has detected air in the tubing It takes approximately 1 ml of air which is approximately 5 inches 12 7 COW TI cm in length entering the orange colored tubing to J LILI cause an alarm KE To correct the problem Press the RUN PAUSE Figure 3 6 key to silence alarm and place pump in pause NO FOOD Alarm mode then check the following 1 Check feeding bag for food If it is empty refill bag and prime the set to remove air from the bag and tubing 2 Check tubing for air bubbles If bag is full but air is present in the tubing disconnect set from patient press and hold the PRIME key until air bubble has moved to the end of the tubing 3 Check cassette receptacle for cleanliness especially around the air sensor If cleaning is necessary refer to CHAPTER 5 CLEANING Page 29 Es 4 Check that an Infinity brand disposable set is loaded into pump properly and door is closed 1 aa a 5 Check disposable set for worn tubing If it is worn replace with a new set NOTE B
19. ND CAUTIONS Warnings gt Use ONLY feeding solutions prescribed by the responsible physician regis tered dietitian registered nurse or other licensed practitioner gt Use ONLY Infinity brand disposable sets to ensure proper fluid delivery Oth ers will not deliver the correct dose may allow dangerous free flow conditions and may generate hazardous fluid pressures which may activate occlusion alarms at unpredictable pressures Low flow rates combined with high dose settings may exceed the life of the disposable set The disposable set must be replaced every 24 hours to main tain delivery accuracy allow proper air and occlusion sensing and prevent growth of bacteria DO NOT PROGRAM RATE AND DOSE COMBINATIONS WHICH EXCEED A 24 HOUR FEED REGIMEN gt The battery capacity is an approximation If you are unsure that enough ca pacity remains for your intended use recharge it gt To avoid electrical shock never clean pump with charger plugged into an outlet or when pump is on Make sure the Infinity AC Adapter Charger is completely dry before plugging into an electrical outlet Do not use Infinity Orange enteral feeding pump for delivery of non enteral solutions Serious injury may result gt Ifan error occurs ERO1 ER99 will appear in display all settings and vol ume counters should be checked and verified before starting a feeding Prior to starting the pump confirm rate dose and food type are program
20. NPUT 5 vac 2 4 K xs J ENTERAL FEEDING pomp Ad DEM our Figure 1 2 Pump Rear 1 Pump Instruction Label 2 Speaker 3 Receptacle for Pole Clamp 4 Serial Number Label 5 Charger Power Connector Infinity Orange Operator s Manual 1 PUMP COMPONENTS Press ON OFF key for 1 5 seconds to either turn Infinity Orange on or off ON OFF FOOD TYPE Press and hold PRIME key to rapidly PRIME VOL TOTAL fill disposable set with fluid Release key to stop RUN PAUSE RATE DOSE Press RUN PAUSE key to start or pause pump or to clear an alarm Figure 1 3 Keypad Layout Press FOOD TYPE key to display and select type of food to be delivered formula or human milk Press VOL TOTAL key once to display volume delivered for current feeding Press key again to display total cumulative volume delivered in all feed cycles since total volume was last cleared Press RATE DOSE key to transition between rate and dose settings Press CLEAR key to reset displayed function to its minimum value Press and hold for three seconds to clear rate dose and volume deliv ered to minimum values at the same time Press key to increase displayed feed function Press and hold key to increase value rapidly Press key to decrease displayed feed function Press and hold key to decrease value rapidly NOTE The following keys only function when pump is in pause mode PRIME CLEAR and 3 Copy
21. OFF and LITE ON However while pump is connected to an A C current the backlight settings can be adjusted The light can be set to ON or OFF With the ON setting the backlight will remain on the entire time pump is plugged in to a live power outlet With the OFF setting the backlight will turn on when a key is pressed and turn off 10 seconds after the last key has been pressed Pump default is ON Figure 2 22 NOTE Regardless of setting the backlight will al ways turn off 10 seconds after pump is turned off Infinity Orange Operator s Manual 16 2 DIRECTIONS FOR USE Max Rate Rate range is 0 1 ml hr up to 300 ml hr However MEI V the rate may be programmed to limit how high the l 1 RH E rate can be set The limits are 50 100 150 200 and 250 ml hr Rate is not limited if user preference Figure 2 23 setting is programmed to NO MAX Pump default is MAX RATE Settings NO MAX Figure 2 23 Max Dose Dose range is 0 1 ml up to 3000 ml However the Mow dose may be programmed to limit how high the M A TOSE dose can be set The limits are 10 20 30 40 50 60 70 80 90 100 and 120 ml Dose is not lim Figure 2 24 ited if use preference setting is programmed to NO MAX DOSE Settings MAX Pump default is NO MAX Figure 2 24 To adjust these settings Key Sequence for Adjusting User Preference Settings LITE OFF MAX RATE MAX RATE MAX
22. Order Number 23401 001 Plug AC Adapter Charger into a wall outlet and plug connector into pump to operate on AC power and or recharge battery Figure 6 1 Infinity Brand Pole Clamp Order Number Z 11981 Thread bolt into receptacle on the back of pump and tighten gray wheel to mount pump on clamp If gray wheel is slightly loosened pump can be rotated to snap into different positions Retighten gray wheel when pump is in the desired position Tighten black wheel to mount clamp on a pole Figure 6 2 Infinity Brand Adjustable Angle Pole Clamp Order Number 26772 001 Thread bolt into receptacle on the back of pump and tighten knob to mount pump on clamp If knob is slightly loosened pump can be rotated to snap into different positions Retighten knob when pump is in the desired position Tighten black wheel to mount clamp on a pole Pull pin to adjust angle Figure 6 3 Infinity Orange Operator s Manual 30 6 ACCESSORIES Infinity Brand Mini Backpack Order Numbers PCK1001 red PCK1002 light green and gray PCK1003 black and gray PCK1004 specialty pack call for current colors Pack holds Infinity pump with a 100 ml or 500 ml bag in the front section or can accommodate 8 1200 ml bag in the rear section Pump is secured with a Velcro strap A Velcro strap secures the neck of the bag The tubing is loaded into pump and any excess length of tubing can be secured with a Velcro tab The downstream tubing
23. RATE HI While pump is running the following may be viewed Figure 2 13 Pump is by pressing the appropriate key rate dose and food Running type E To view the amount delivered in the current feeding press the VOL TOTAL key Figure 2 14 This counter CJ will reset to 0 when the previously programmed dose VENE m has been completed and a new feeding is started This counter will also reset to 0 if a feeding is inter rupted and rate or dose is changed or if the pump is turned off and then back on again Figure 2 14 Amount Currently Delivered TTI OTL To view the amount delivered over the course of sev eral feedings press the VOL TOTAL key a second EIF time Display will read TOTL then the amount This Ex counter never resets itself It can only be reset by the Figure 2 15 Total Amount user Figure 2 15 Delivered While pump is running the settings cannot be changed and the Prime feature is disabled If you want to stop pump at any time press the RUN PAUSE key Display will show rate and pump will be in pause mode Pump will save the memory of where it was in the feeding before being paused Or turn pump off by pressing the ON OFF key 11 Copyright 2008 ZEVEX Incorporated 2 DIRECTIONS FOR USE To restart pump when in paused mode press the RUN PAUSE key The pump will restart the feeding at the point where it was paused NOTE If pump is turned off and turned back o
24. ackpack Cutaway View of Internal Cutaway View of Internal Straps Compartments 31 Copyright 2008 ZEVEX Incorporated 6 ACCESSORIES Infinity Brand Waist Pack Order Numbers PCK3001 black and gray Pack holds Infinity pump with 8 100 ml or 500 ml bag Pump is secured with an elastic strap Velcro strap secures the neck of the bag The tubing is loaded into pump and any excess length of tubing can be secured with a Velcro tab The downstream tubing then feeds through a port at bottom of pack either side Dimensions 7 H 11 Wx 3 D Feeding Bag Strap Tubing Strap Figure 6 10 Waist Pack Figure 6 11 Waist Pack Cutaway View of Internal Compartment and Straps Infinity Brand Backpack Order Numbers PCK4001 black and gray Pack holds Infinity pump with a 100 ml 500 ml or a 1200 ml bag Pump is secured with a Velcro strap A Velcro strap secures the neck of the bag The tubing is loaded into pump and any excess length of tubing can be secured with a Velcro tab The downstream tubing then feeds through a port at bottom of pack either side Also included in this pack is a pocket that may be used to hold an ice pack Dimensions 17 H 8 W x 4 D Feeding Bag Strap Ice Pack Pocket 1200 ml amp 500 ml Bag Compartment Tubing Strap Pump Compartment Tubing Strap Figure 6 12 Backpack Figure 6 13 Backpack Cutaway Figure 6 14 Backpac
25. d settings may return to their default values Check the pump regularly if operating near Sources of electromagnetic emissions The Infinity Orange can safely be operated on commercial aircraft and is designed in accordance with EN 60601 1 2 EN 60601 1 4 and RTCA DO160D standards for electromagnetic emissions and immunity Guidance and manufacturer s declaration electromagnetic emissions The Infinity Orange is intended for use in the electromagnetic environment specified below The customer or the user of the Infinity Orange should assure that it is used in such an environment Emissions Test Compliance Electromagnetic environment guidance RF emissions Group 1 The Infinity Orange uses energy only CISPR 11 for its internal function Therefore its RF emissions are very low and are not RF emissions likely to cause any interference in nearby CISPR 11 Class B electronic equipment Harmonic emissions Class A IEC 61000 3 2 The Infinity Orange is suitable for use in all establishments including domestic establishments and those directly con Voltage nected to the public low voltage power fluctuations flicker x 0 that les buildi Complies um vi or 1 at supplies buildings IEC 61000 3 3 used for domestic purposes Infinity Orange Operator s Manual 36 10 WARRANTY Infinity Orange Disposable Set Displacement Infinity Orange Disposable Set displaces approximately 6 ml of fluid when
26. erence Settings section Page 16 for in structions to change this setting Infinity Orange Operator s Manual 4 1 PUMP COMPONENTS Disposable Set The only disposable sets approved for use with Infinity Orange pump are gt Infinity Orange 100 ml Bag Set Order Number INF0100 EnteraLite Infinity 500 ml Bag Set Order Number INF0500 EnteraLite Infinity 1200 ml Bag Set Order Number INF 1200 EnteraLite Infinity Spike Set Order Number INF0010 F me 9 Figure 1 9 Infinity Brand 100 ml 500 ml or 1200 ml Bag Set gt 0 ni Figure 1 10 Infinity Brand Spike Set Cassette y Symbol Downstream Tubing Upstream Tubing 100 ml 500 ml or 1200 ml Feeding Bag Barbed Enteral Adapter Adapter Protective Cover Spike Protective Cover Spike GO 4 O O1 5 Copyright 2008 ZEVEX Incorporated Consult Accompanying Documents Figure 1 11 Consult Accompanying Documents Figure 1 12 Feeding Bag Connection Figure 1 13 Patient Connection Figure 1 14 TYPE BF Shock Protection Figure 1 15 IEC 529 Figure 1 16 Single Patient Use Figure 1 17 DEHP free Figure 1 18 Replace Every 24 Hours y X SINGLE PATIENT USE ONLY DEHP FREE 24 HOURS 1 PUMP COMPONENTS Symbols Brief instructions for operation of pump as well as a brief explanation of each alarm message which pump may commun
27. ge i Rinsing Pump Under Stream of Water pp Pole Clamp Pole Clamp with Pump Attached to IV 06 2 11 2 12 2 13 2 14 2 15 2 16 2 17 2 18 2 19 2 20 2 21 2 05 2 23 2 24 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 10 3 11 3 12 3 13 5 1 6 1 6 2 Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Infinity Orange Operator s Manual 40 LIST OF FIGURES Adjustable Angle Pole Clamp Adjustable Angle Pole Clamp with Pump Attached to IV Pole 30 Mini Backpack Cutaway View of Internal Compartments 31 Mini Backpack Cutaway View of Internal Straps 31 Super Mini Backpack Super Mini Backpack Cutaway View of Internal Compartments Super Mini Backpack Cutaway View of Internal Straps seid Re Paes eee A EE E ni 32 Waist Pack Cutaway View of Internal Compartment and Straps 32 SEO 32 Backpack Cutaway View of Internal Compartments 2 Backpack Cutaway View of Internal Straps 00 0 sss 32 Head Efect On 07 35 41 Copyright 2008 ZEVEX Incorporated 6 3 6 4 6 5 6 6 6 7 6 8 6 9 6 10 6 11 6 12 6 13 6 14 8 1 Figure Figure Figure Figure Figure Figure Figure Figure Fi
28. gure Figure Figure Figure Figure WHO TO CALL Additional Information YOUR HEALTHCARE PROVIDER YOUR PHYSICIAN ZEVEX Incorporated 4314 ZEVEX Park Lane Salt Lake City Utah 84123 USA Customer Service and Technical Support 800 970 2337 www zevex com Infinity Orange Operator s Manual 42 INDEX Plug Symbol 15 Running on Battery Power 14 C Carry Packs 31 Cleaning Acceptable Cleaners Disinfectants 29 To clean the AC Adapter Charger 29 To clean the Carrying Packs 29 To clean the Infinity Orange Enteral Feeding Pump 29 CLEAR Key 3 D Directions for Use Removing Air 7 Display 3 Battery Symbol 4 Display Light 4 Fuel Gauge Symbol 4 Run Symbol 4 Wall Plug Symbol 4 Disposable Set 4 100 ml Bag Set 5 1200 ml Bag Set 5 500 ml Bag Set 5 Adapter Protective Cover 5 7 Barbed Enteral Adapter 5 7 Cassette 5 Downstream Tubing 5 Features 33 Spike 5 Spike Protective Cover 5 Spike Set 5 Upstream Tubing 5 Disposable Set Displacement 37 Dose 10 33 Copyright 2008 ZEVEX Incorporated INDEX Symbols Key 3 Key 3 A AC Adapter Charger 15 30 Accessories AC Adapter Charger 30 Adjustable Angle Pole Clamp 30 Backpack 32 Mini Backpack 31 Pole Clamp 30 Super Mini Backpack 31 Waist Pack 32 Adjustable Angle Pole Clamp 30 Alarms 20 5501 ER99 20 LOAD SET 20 LOW BATT 14 20 NO FLOW IN 21 27 NO FLOW OUT 21 27 NO FOOD 22 PUSH RUN TO FEED 2
29. i cate are printed on the label attached to pump These are not intended to be used in place of the Operator s Manual They are simply a quick reference guide Please read the Operator s Manual be fore operating the Infinity Orange The bag symbol is printed on pump door over port where upstream tubing enters pump The patient symbol is printed on pump door over port where downstream tubing exits pump EN 60601 1 Type BF degree of protec tion against electrical shock No electrical connection to patient Drop from any angle from height of 3 feet shall not dam age pump operation IEC 529 degree of protection against water entering the enclosure Water jets from any direction shall have no effect This symbol is printed on pump delivery sets It indicates only one patient should use each disposable set This symbol is printed on pump delivery sets It indicates pump delivery sets are made with materials that do not contain the plasticizer DEHP This symbol is printed on pump delivery sets It indicates pump delivery sets should be replaced every 24 hours Infinity Orange Operator s Manual 6 2 DIRECTIONS FOR USE 2 DIRECTIONS FOR USE Recommendation for First Use Since battery may not be fully charged when pump is first received it is recom mended that battery be charged for 6 hours prior to operating on battery power 1 hA Figure 2 1 Spike Container Cover Receptacle F
30. igure 2 3 Remove Cover from Barbed Adapter Place Cover on Pole Clamp Copyright 2008 ZEVEX Incorporated see Page 15 for additional information Priming and Loading the Disposable Set Step 1 If you are using the spike set with a vented bottle or pre filled bag Remove protective cover from spike and insert spike into spike adapter of formula con tainer Figure 2 1 If you are using the 100 ml 500 ml or 1200 ml disposable set Hold bag upright and pour in feeding solution Figure 2 2 Close cap securely NOTE Blenderized or aggressively mixed solutions may have foam If using this type of solution allow it to sit for 10 to 15 minutes before pouring into bag This will reduce the chance of an alarm due to air in the tubing Step 2 Remove protective cover from barbed adapter If using pole clamp protective cover may be inserted into the receptacle on back of clamp Figure 2 3 NOTE If set is to be used with a carry pack all air must be removed from bag and tubing Continue to step 3 for instructions on removing air If set is to be hung above pump i e on an IV pole you may skip to step 4 Figure 2 4 Squeeze Bag Figure 2 6 Tubing Figure 2 7 Tubing Segment Segment Being Pinched Being Punctured by Fingernail 2 DIRECTIONS FOR USE Step 3 Turn bag upside down and gently squeeze Tilt bag as needed to keep air at tubing port Figure 2 4 Step 4 Ge
31. k Cutaway View of Internal Compartments View of Internal Straps Infinity Orange Operator s Manual 32 7 SPECIFICATIONS SPECIFICATIONS Pump Dimensions 1 95 H x 5 65 W 4 05 D Pump Weight 14 4 02 411 0 g Type Lithium lon Life 24 hours 125 ml hr Charge Time Approximately 6 hours Charge Level Indicator Compact Wall Charger Backlit LCD Any Range 0 1 300 ml hr Increment 0 1 ml hr from 0 1 ml hr to 9 9 ml hr 1 ml hr from 10 ml hr to 300 ml hr Accuracy t 5 or 050 ml hr whichever is greater see page 40 Range 0 1 ml to 3000 ml Increment 0 1 ml from 0 1 9 9 ml 1 ml from 10 3000 ml Current Dose Status Accumulated When Pump is on or off Yes Yes Automatic Free flow Protection No Drip Chamber DEHP free 33 Copyright 2008 ZEVEX Incorporated SIZE BATTERY DISPLAY OPERATING ORIENTATION FLOW RATE DOSE VOLUME DISPLAY PROGRAM MEMORY RETAINED PEDIATRIC USE PRIME DISPOSABLE SET FEATURES 7 SPECIFICATIONS ALARMS ER01 ER99 Self test error LOAD SET Set not loaded properly LOW BATT Battery Low NO FLOW IN Upstream occlusion 5 psi 34 kPa 3psi 21 kPa psi pounds per square inch kPa kilopascals NO FLOW OUT Downstream occlusion 12 psi 83 kPa 3psi 21 kPa and 30 sec delay before alarm 15 psi 103 kPa 2psi 14 kPa and 5 sec delay before alarm 18 psi 124 kPa 2psi 14 kPa a
32. lenderized or aggressively mixed solutions T may have foam Small foam bubbles may collect in the air sensor area and must be cleared in order to avoid a NO FOOD alarm Allowing foamy solutions to sit for 10 to 15 minutes after mixing and prior to pour H E TI ing into the bag will reduce the amount of foam J PUSH RUN TO FEED Figure 3 7 Pump will sound a dual tone beep repeatedly and Figure 3 7 PUSH RUN TO display will read PUSH RUN TO FEED FEED Alarm Infinity Orange Operator s Manual 22 3 ALARMS MESSAGES AND INDICATIONS Why This alarm has occurred because pump has been in pause mode for 2 minutes To correct the problem Press the RUN PAUSE key to silence alarm and place pump in pause mode again Program and use pump or press the ON OFF key to turn it off SHUT DOOR Figure 3 8 Pump will sound a dual tone beep repeatedly and display will read SHUT DOOR Why This alarm has occurred because the pump door was opened while pump was running To correct the problem Press the RUN PAUSE HER key to silence alarm and place pump in pause mode IL I then shut the door Check door is latched securely If door will not stay closed check door latch and Figure 3 8 latch pocket on pump are not broken or cracked SHUT DOOR Alarm Messages DOSE DONE Figure 3 9 This message indicates a feeding dose has been delivered TUGE To clear pump Either press the ON O
33. m dose value such as 20 ml Press the or key to scroll between settings until the desired value is displayed If setting is as desired do not press either key Step 7 Press the ON OFF key to turn pump off Setting changes will be saved automatically NOTE Once user has changed the desired user preference setting it is not necessary to view the remaining user preference settings Each change will be automatically saved as it is made NOTE Pump will turn off automatically after 2 minutes in the User Preference Settings if the user does not turn it off before then Infinity Orange Operator s Manual 18 3 ALARMS MESSAGES AND INDICATIONS ALARMS MESSAGES AND INDICATIONS Following is a list of all alarms display messages and indications that are used by the Infinity Orange enteral feeding pump Each alarm message or indication is described in detail on the following pages Description Page Alarms ERO1 ER99 LOAD SET e osier feed diner entend LOW ppp trente NO FLOW IN NO FLOW OUT 3 itusscese eiie ee eov RE anse e NO FOOD MES PUSH RUN TO FEED SHUT DOOR its ence ete t eere r e ativan teret ede cati tes Co e Messages DOSE DONE onn io Pee ens 23 Indications STOP GQ itcr reino Ea ele ren tian Eo ode dba CON FIRM DOSE AND FOOD TYPE nis Battery Doesn t Hold Its Charge ornnes Battery Doesnt Charg eret er rtr erret erts Charger Installed but No Plug Symbol Visible
34. med as prescribed to avoid an unsafe feeding condition Infinity Orange Operator s Manual iv Cautions Federal law U S A restricts this device to sale by or on the order of a physi cian registered dietitian registered nurse or other licensed practitioner Dispose of Infinity Orange Disposable Sets properly as required by local law gt If any leaks are detected in the disposable set stop pump operation and disconnect set from patient and replace with a new disposable set gt Care should be used when manually priming delivery set to ensure cassette is not damaged by excess force Do not overload carry packs with personal items Pump function may be af fected by kinked or pinched tubing and or unintentional button presses V Copyright 2008 ZEVEX Incorporated Infinity Orange Operator s Manual 1 PUMP COMPONENTS 1 PUMP COMPONENTS Infinity Orange Small Volume Enteral Feeding Pump Figure 1 1 Pump Front Door Pump Wheel Display Upstream Pressure Sensor Air Sensor Downstream Pressure Sensor Receptacle for Cassette Keypad co O O1 ND 1 Copyright 2008 ZEVEX Incorporated 0 lt 1 PUMP COMPONENTS Infinity Orange Small Volume Enteral Feeding Pump Orange Sov lake Ciy UT eae He Tux roe tues 800 370 237 NOT FOR IV Ue EDING ONLY Manus EIC xc uL E 1 Deni FEED PER odes aim 1 I
35. move Cover from Barbed Adapter Place Cover on Pole Clamp 7 Squeeze DA sinusite 8 xi TUDING 8 Tubing Segment Being Pinched sa 8 Tubing Segment Being Punctured by Fingernail ssssussse 8 Seat Cassette CSS Pam NO 9 Priming reo eT R 9 39 Copyright 2008 ZEVEX Incorporated 1 1 1 2 1 3 1 4 1 5 1 6 43 1 9 1 10 1 11 EF 1 13 1 14 1 15 1 16 de 1 18 2 1 55 2 3 24 25 26 27 2 8 2 9 2 10 Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure LIST OF FIGURES Total Amount Delivered nement DOSE DONE Battery Power Indicator iie en Fuel Gauge ganas Alarm Volume Settings BEEP LOW and BEEP HIGH Settings Lock 46 end LOGK iriiri n annae Dose Done Settings BEEP WHEN DONE and MUTE WHEN DONE Backlight Settings LITE OFF and LITE ON LOAD SET i i P Rt o VA CUN NO FLOW IN Alarm PUSH RUN TO FEED usce rre evene i aa SHUT BOOR HH DOSE DONE Message canner E rr ri EErEE E 5 Battery Symbol and the E and F of the Fuel Gau
36. n again the volume delivered coun ter resets to 0 and food type resets to formula Rate dose and food type must be confirmed before restarting the pump with a new feeding NOTE Any changes to pump settings except food type during a feeding cycle will cause pump to start a new feeding it will not start where it left off Rate dose and food type must be confirmed by viewing each parameter before restarting the pump Feeding Completion When the dose has been completely delivered pump TNL C will stop running and display will read DOSE DONE Pump will be in a pause mode until it is turned off or ALI JL feeding is restarted To clear DOSE DONE press and E hold the ON OFF key for 1 5 seconds to turn pump off or press the RUN PAUSE key to put pump in pause TN I mode Adjustments to settings can be made at this LILI NL time or press the RUN PAUSE key a second time to start another feeding using same rate dose and food type settings Confirmation of rate dose and food Figure 2 18 DOSE DONE type is required before begining another feeding If you would prefer the alarm to sound when the dose is complete you can change the pump dose complete alarm setting to BEEP WHEN DONE See the User Pref erence Settings section Page 16 for instructions to change this setting When set to BEEP WHEN DONE the pump will stop at the end of the feeding beep intermit tently and display will read DOSE DONE Figure 2 1
37. nd 1 sec delay before alarm NO FOOD Air in tubing bag or set may be empty PUSH RUN TO Pump is on in pause mode for 2 minutes FEED SHUT DOOR Door opened while pump was running ACCESSORIES AC Adapter Charger Multi position Pole Clamp Adjustable Angle Pole Clamp Multi purpose Infinity brand Custom Carry Packs WARRANTY 2 years OPERATING Temperature 41 F to 104 F 5 C to 40 C ENVIRONMENT Humidity 30 to 95 noncondensing STORAGE Temperature 4 F to 149 F 20 C to 65 C ENVIRONMENT Humidity 10 to 95 noncondensing CLASSIFICATION Infinity Orange Enteral Feeding Pump with internal battery Type INFORMATION BF Applied Part Infinity Orange AC Adapter Charger Class II Infinity Orange Operator s Manual 34 8 IMPORTANT PEDIATRIC CONSIDERATIONS IMPORTANT PEDIATRIC CONSIDERATIONS Infinity Orange can be used on pediatric patients if the specifications of pump meet delivery requirements of the patient The specifications of primary impor tance are gt The flow rate range of Infinity Orange is 0 1 ml hr to 10 ml hr in 0 1 ml hr incre ments and 10 ml hr to 300 ml hr in 1 ml hr increments gt The Infinity Orange pump delivers the dose at the specified rate within 5 or 050 ml hr whichever is greater volumetric flow rate accuracy under the following conditions utilizing ZEVEX Infinity brand disposable sets fluid head height at 6 0 inches
38. ntly pinch teal colored tubing below N symbol Hold this position until air is removed from tubing Gently squeeze bag at same time to assist fluid flow If fluid does not flow pinch pressure may be too strong Figure 2 5 NOTE Inside the teal colored tubing below the symbol is the in line occluder The in line occluder is the built in anti free flow valve By pinching tubing gently the tubing moves away from the in line occluder allowing fluid to flow Figure 2 6 It is important to only pinch the tubing below the symbol to avoid damaging the in line occluder NOTE Be extremely careful to pinch tubing using only the flat soft part of your finger Do not use fingernails when pinching tubing doing so may puncture the delivery set Figure 2 7 If you suspect that the delivery set has been punctured please discard and use a new set NOTE Air may also be removed from tubing using the pump prime feature See step 7 for instructions on using the pump prime feature Infinity Orange Operator s Manual 2 DIRECTIONS FOR USE Figure 2 9 Close Pump Door TOP ET ET 9 LI IET e EMF EMF Figure 2 10 Priming Indication Step 5 Loop silicone tubing around pump wheel stretching lightly Seat cassette into pump Figure 2 8 Close pump door Figure 2 9 NOTE If 1200 ml set is to be used with Mini Back pack load set into back secti
39. on of pack and thread cassette through port in bottom corner of pack prior to loading cassette into pump Step 6 Press and hold ON OFF key for 1 5 seconds to turn pump on While pump runs through a self test display will light and an audible alarm will sound as pump displays the nine digit serial number three digits at a time for one second each The display will then show the letter N followed by a number which is the software revision Next all segments of display will be shown for 2 seconds Verify all display segments and sym bols are active The self test is complete and pump will then display last programmed rate and will be in pause mode If any air is still in the tubing continue to Step 7 to use pump prime feature Step 7 Press and hold PRIME key Alarm will sound once and pump will begin pumping at the maximum rate of 332 ml hr Display will read TO STOP LET GO Figure 2 10 Once all air is removed from tubing release key Pump will stop display will revert to last programmed rate and pump will be Copyright 2008 ZEVEX Incorporated in pause mode 2 DIRECTIONS FOR USE Operating the Pump A Single Feeding Example If you want to deliver 50 ml of enteral feeding solution at a rate of 100 ml hr and then stop the pump Key Sequence for A Single Feeding Example C 400 mihr D 2 RATEDOSE CZ 50 ml ON OFF e N RUNPAUSE A FooD TYPE FORM ULA
40. r half of bag while pinching the orange colored tubing just below the drop symbol Hold this position until all air has passed through the orange segment of tubing 4 Are air bubbles trapped inside the cassette Pause pump and change food type by pressing FOOD TYPE key and either or to change between formula and human milk 5 Has the appropriate food type setting on the pump been selected for this feeding If alarm continues contact your healthcare provider or ZEVEX Customer Service at 800 970 2337 for assistance Infinity Orange Operator s Manual 26 4 TROUBLESHOOTING GUIDE LOAD SET Alarm 1 Is door closed Turn pump off Unload and reload delivery set cassette securely Make sure door is closed securely Turn pump back on Contact your healthcare provider or ZEVEX Customer 2 ls door cracked or Service at 800 970 2337 to receive a new door tab on inside of door broken Contact your healthcare provider or ZEVEX Customer Service at 800 970 2337 for assistance NO FLOW IN or NO FLOW OUT Alarms NO FLOW IN Occlusion between delivery set and pump NO FLOW OUT Occlusion between pump and patient 1 Is delivery set tubing pinched kinked or clogged Check delivery set for obstructions or kinks in tubing Correct blockage and resume feeding 2 Is tab on inside of Contact your healthcare provider or ZEVEX Customer door broken Service at 800 9
41. right 2008 ZEVEX Incorporated 2 o lt D D CA 9 S e m ae 03 0 MIMMIN MMW E RATE DOSE VOLUME EMIF 6 E Figure 1 4 Display Segments NA NA NAN YN ANIAN NI som Figure 1 5 Alphanumeric Characters and Units RATE DOSE VOLUME Figure 1 6 Setting Indicators un v Figure 1 7 Run Indicators ERF 6 EI Figure 1 8 Power Indicators 1 PUMP COMPONENTS Display The display includes large alphanumeric char acters as well as smaller symbols and words All segments and symbols on the display are shown in Figure 1 4 Settings and messages are displayed in large alphanumeric characters Figure 1 5 When the large alphanumeric characters dis play numbers one of the smaller words below the characters indicates which function is be ing displayed Figure 1 6 The run symbol indicates pump is in run mode Figure 1 7 The wall plug symbol indicates the charger is plugged in and connected to a live power outlet The battery symbol indicates pump is running on battery power only The fuel gauge symbol indicates how much battery charge remains Figure 1 8 NOTE When operating on A C power the dis play light will remain on When operating on battery power the display light will automati cally turn off 10 seconds after the last key is pressed If you would prefer the light to turn off when connected to an outlet you can change the pump light setting to OFF See the User Pref
42. roximately 10 minutes then wipe pump clean with a damp cloth or sponge 5 bleach and water solution Multipurpose household disinfectant cleaner Rinse pump by holding under a stream of warm water Then dry with a clean cloth Figure 5 1 Rinsing Pum NOTE Avoid harsh cleaners disinfectants They may binh Shoan es cause damage to pump surfaces and may affect pump functionality ZEVEX has tested the following disinfectants for acceptability for cleaning disinfecting the Infinity Orange pump These cleaning products are categorized below Metrex CavaCide Ball Ruthless MetriCide 28 Wex Cide 128 5 Bleach and Water Solution Alcohol Warm Soapy Water Standard Dish Soap Vesphene Ilse To clean the Carrying Packs The Infinity brand packs are machine washable Use cold water and gentle cycle whenever possible Hang to dry To clean the AC Adapter Charger Infinity Orange AC Adapter Charger normally does not require cleaning When desired a dry or slightly damp cloth may be used to clean the outside surface of AC Adapter Charger while it is disconnected from the wall outlet 29 Copyright 2008 ZEVEX Incorporated Figure 6 1 AC Adapter Charger Figure 6 2 Pole Clamp Pole Clamp with Pump Attached to IV Pole 0 Figure 6 3 Adjustable Angle Pole Clamp Adjustable Angle Pole Clamp with Pump Attached to IV Pole 6 ACCESSORIES ACCESSORIES Infinity Brand AC Adapter Charger
43. te Dose or Interval Feeding programming option listed in the operator s manual It is recommended that a single feeding regimen for specific dose be used for this particular user group DIRECTIONS FOR USE gt Operating the Pump A Single Feeding Example Pages 10 12 The specific dose regimen is extremely important when a licensed healthcare clinician prescribes the use of feeding liquids other than commercially available enteral formulas or human milk such as but not limited to blenderized whole foods Use of this type of nutrition may cause sticky solids which could cause an obstruction of the optical sensor It is recommended that all users clean and maintain the pump and optical sensors according to manufacturer s recommendations 49522 Rev A TABLE OF CONTENTS Page TABLE OF CONTENT o gt es i PRODUCT OVERVIEW mm GO PUOI ERN iii INDICATIONS FOR USE iii LIST OF WARNINGS AND CAUTIONS iv Nur iv T PUMP COMPONENTS ananas 1 Infinity Orange Small Volume Enteral Feeding Pump ss 1 joo 3 BIET 4 Disposable SOE 5 6 Priming and Loading the Disposable Set Operating the Pump A Single Feeding Example ree ins nest 10 The Battery Y 14 R unning on Battery POWER 5 aco oett din dansante dat 14 Charging tlie Battery 22820 cisenmencisencenennenmensiers 15 User Preference nent meta Fey Pea EE ke E
44. u e Ka Rue 16 ALARMS MESSAGES AND INDICATIONS int 19 TROUBLESHOOTING GUIDE 5 irit siss garnais pasiaina 26 CLEANING immenses 29 ACCESSORIES ea 30 SPEGIPICATIONS ice BOR NORIS E ORI FREE RENE xaahilen OR DUM TI ble bu AIR HUS pO HM 33 IMPORTANT PEDIATRIC CONSIDERATIONS ini 35 ADDITIONAL TECHNICAL INFORMATION 4 MWMARRANTY gt UST OF PIGUBES ORDER Ka 1 Copyright 2008 ZEVEX Incorporated ty Orange Operator s Manual PRODUCT OVERVIEW The Infinity Orange is a rotary peristaltic enteral feeding pump designed to de liver programmed doses of enteral nutrition solutions at selectable rates Itis easy to use with a simple user interface and keypad ZEVEX technology allows an ac curacy rate of 5 and the ability to safely operate in any orientation The Infinity Orange system includes a complete line of Di 2 ethylhexyl phthalate DEHP free pump delivery sets with automatic free flow protection The Infinity Orange is designed for both hospital and alternate care use It is durable water resistant and easily carried in a ZEVEX carry pack The Infinity Orange s size weight accuracy and portability promote and support health im proving physical activity INDICATIONS FOR USE The Infinity Orange enteral feeding pump is a rotary peristaltic pump designed to deliver programmed doses of enteral nutrition solutions at selectable rates iii Copyright 2008 ZEVEX Incorporated LIST OF WARNINGS A
45. us of battery during charg ing disconnect charger from pump and turn on pump NOTE If pump shut down due to low battery charging less than 10 minutes may result in an ER99 alarm Fully charge battery if depleted see page 20 to clear alarm 15 JEEP HIGH Figure 2 19 Alarm Volume Settings BEEP LOW and BEEP HIGH ONEK LULK Figure 2 20 Settings Lock UNLK and LOCK WHEN TONE WHEN JUNE Figure 2 21 Dose Done Settings BEEP WHEN 2 DIRECTIONS FOR USE User Preference Settings There are six user preference settings These set tings can be changed to fit the user s needs Alarm Volume The alarm has two volumes high or low Pump default is low Figure 2 19 Settings Lock This allows user to set a rate dose and food type and then lock those settings so they cannot be changed unintentionally This will also lock the vol ume counters from being unintentionally cleared Pump default is unlocked Figure 2 20 Dose Done There are two settings for the DOSE DONE alarm MUTE WHEN DONE or DEEP BEEP WHEN DONE Pump default is MUTE WHEN DONE Figure 2 21 Backlight ML he To conserve battery life the backlight will turn off automatically 10 seconds after the last key has been pressed DONE and MUTE WHEN DONE TE OFF We FN LIN FF m Figure 2 22 Backlight Settings LITE
46. y ZEVEX and is the ONLY WARRANTY GIVEN FOR THE SALE OF PRODUCTS OR SERVIC ES NO WARRANTIES IMPLIED IN LAW INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PAR TICULAR PURPOSE SHALL APPLY ZEVEX WILL BE LIABLE IN ANY EVENT ONLY FOR THE PURCHASE PRICE OF THE DEFECTIVE PRODUCT BUT NOT FOR ANY CONSEQUENTIAL DAMAGES This Warranty may not be modified amended or otherwise changed except by a written document properly executed by a corporate officer of ZEVEX ZEVEX Inc voids the warranty if the Infinity Orange pump is opened or tampered with in any way without prior authorization from ZEVEX Inc Infinity Orange Operator s Manual 38 LIST OF FIGURES LIST OF FIGURES Description Page Pump Front SF 2 4 3 Display 590 4 Alpnanumence Characters and UNIS issus 4 og 4 Te 4 Pwer 4 Infinity Brand 100 ml 500 ml or 1200 ml Bag Set 5 Infinity Brand Spike SOL isse vsevse stante ttt ERES EEDA 5 Consult Accompanying DOGUMEN S sisi 6 Feeding Bag Connection sinusite 6 Patient Connection 6 BF Sho0k gt 6 2 Single Patient USE 6 ERAISTEA AAN RAAN iR anaE 6 DEHP MOS Replace Every 24 HOUIS 1e eie ebore EE 6 SpIKa COANE apee eepe Eana RAEE O ARRIE de m me 4 SAG REPERI RR T TIE 7 Re