1. Using the camera Parts of the camera e ee eoe eoc oocoocoocoocoocoocococoocoooooooooooo Microphone Used to talk to someone at the entrance Camera lens Ho HOME SYSTEM Speaker Call button When you are talking to Used when calling your neighbor someone at the entrance your voice will be heard outside X The camera is subject to change without prior notice HS 6270 User s Manual 19 Troubleshooting Please check the manual before reporting a malfunction Check the list below before requesting for repair Symptom Check the following Reference e Is the red light on the control panel The panel is not working turned on Check the power Is the brightness setting appropriate Check the menu The screen is fuzzy e Are there stains in the screen and camera lens e Is there moisture in the camera The alarm has been activated and cannot be deactivated even after pressing the reset button e Did you follow the steps in sequence Check the menu e Check for open doors burglar alarm system The exit mode cannot be set The functions are not working as intended e Refer again to the user s manual The following are not malfunctions The doorphone camera and common entrance camera screens may become fuzzy under strong sunlight or headlights The image may flicker slightly after pressing the call b
2. message Security system is not activated Please check and try again is displayed gt Press Away When setting the away mode the away status is transmitted to the guard post Caution The system considers you an intruder if you do not leave the house while the away warning alarm sounds As a result the security system is activated Sleep stay Mode Xx You can activate the security system when you are at home 1 Press Away 2 Press 3 The Stay lamp and Safety Zone lamp for monitoring are then lit Message Security system is activated During setting the Sleep mode is not set if the security zone is breached or sensed The corresponding safety zone lamp then blinks and the message Security system is not activated Please check and try again is displayed gt Press Away When setting the away mode the away status is transmitted to the guard post When the sleep mode is activated the living room is not monitored thus enabling you to move freely inside the house Ifyou have a visitor or wish to go outside while the sleep mode is activated you need to deactivate the sleep mode first 14 Honeywell Co Ltd Security and Alarm Functions Room Mode deactivating the away and sleep modes Xx You can deactivate the security system 1 Input the four digit password 63 3 Message The security system is deactivated When you open the entrance
3. sound If desires to input again start with the step 3 If desires to confirm the time start from the step 3 of Setting and change the entry exit delay Press J to enter other menu setting Toexitthe function setting mode press the button Ex Checking the entry exit delay gt Press E gt The clue sound zero four HS 6270 User s Manual 9 Function Setting Setting Changing Deleting and Checking the Password x One household can have up to four passwords x Be sure to remember the password for deactivating the security system and alarm Setting Changing the Password Press the 8 button Press Enter the password four digits Press To save the password to B E press the corresponding button Tocontinue entering passwords start with the step 3 To check the password you entered go to Checking Password 3 Toend the function setting menu press the O button Ex To setthe password to 1111 gt O 0 0000 0 0 gt The number is set Deleting the Password Press the button Press Press To delete the password from B E press the corresponding button Tocontinue deleting passwords start with the step 3 To check the password you entered go to Checking Password 3 Toend the function setting menu press the button Ex To delete the password saved to 1 gt O 0 0 gt The numberis set Checking
4. 4 Sleep stay Mode tti 14 Room Mode deactivating the away and sleep modes 15 In Case of Emergency Reporting an Emergency E OE E A E AR 15 In Case of Fire or Gas Leakage vv een 15 In Case the Security Alarm is Activated il Electronic Bullet Board Function eee Saving Image Function AAEE ha EI EEN EE Hach ev EEE A ETE OE ua eae Re canny E NEM teem 2 a kaa 14 Hae Saunas Naa AS aa A ENARE eked UG A thohea SEARES eh A ERREN A es Sa AEN as ea Kaa say 5 REES EEI IEEE TAEAE STE ENET 6 Setting Changing Deleting and Checking the Password ea na a era Oa 10 Interphone Function Answering the Interphone seere 12 Making a Call over the Interphone eren 12 Reaching the Guard Post Taking Calls from the Guard Post 00717711 12 How to Reach the Guard Post a 12 Talking to Someone at the Common Entrance Taking Calls from the Common Entrance 13 Deactivating the Emergency Alarm 16 Testing the Alarm Sound Fee ACHR ARE creer 16 sh tgeseniith ouch bedi ay 0h enndutend lok T A T A weeds tnekesieesans taekey ween ae 1 T e EA E EA A E te E A eee 18 AP A PEE APT PN AA E A E A A A A A E TEA 19 EERE IEEE EELA TE PS T E EITE EA A PTEE 20 nd ana ai dE SENERE RA E EEE tay th E Cay RERA A N a 21 T E E EO A E S E E E E T 22 HS 6270 User s Manual 1 Safety precautions To prevent property damage make sure you have read the Safety Precautions before using your system E The following symbols denote the degree of damage th
5. Honeywell for the safety and happiness of your home Home System HS 6270 CEAD E To get the best use of the product please read the user s manual carefully before using the product E Keep the user s manual at an easily accessible place and make it available to the next user E The specification of product picture may vary the model E The location of the lamps in the pictures may vary by model Honeywell Accessing the fire gas control test mode Press oB Press OE Press to shift to fire test mode x Referto page 16 formore details Press B to shift to gas test mode Safety Precautions Using the Camera Troubleshooting Product Specifications Product Warranty Contents Usage Suggestions Parts of HS 6270 shee thse deus ban lates AES IAA EANA T Function Setting Adjusting the Volume of the Bell reee m Adjusting the Brightness of the Screen oeereeee 7 7 Adjusting the Volume of the Phone se If Setting the Safety Zone cee eee 8 Setting Changing and Checking the Exit Entry Dela 9 Phone Call Function Telephone Function Answering the Phone este A E AN E NTA 11 Making a Phone Call E IAA IAIA E A A E A 11 Talking to Someone at the Door Taking Calls from the Door Sip uubadeses oo buUan eh 405 chee WeGEs ch45 Satan ees eae 11 Monitoring the Door EDIE N LG OF SRO CTO DONTE OTS Ey CEPTS EERE TERE R EEC Ad Security and Alarm Functions Away Mode eet 1
6. alfunction malfunction Repair details Berean incnaiee Xx The cause of malfunction is very important please give as much details as you can X This product is subject to change without prior notice Contact 22 Honeywell Co Ltd Honeywell Security amp Data Collection For more information Asia Pacific Headquarters Tel 86 21 5257 4568 Australia Tel 61 1300 368 755 China Tel 86 755 2518 1226 Hong Kong Tel 852 2405 2323 www asia security honeywell com security ap honeywell com Automation amp Control Solutions Honeywell Security Asia Pacific India Tel 91 124 5105671 Korea Tel 82 2 799 6109 Singapore Tel 65 6333 9563 Tainwan _ Tel 886 2 2245 1000 Honeywell Honeywell International Inc Jan 2009 www security honeywell com 2009 Honeywell International Inc m The location of the lamps and specifications as shown in the picture above may vary slightly from the actual product The World s Best Customer Service We at Honeywell provide the world s best customer service to enable our customers to enjoy a convenient and happy life Honeywell The contents of this user s manual are subject to change without prior notice Automation amp Control Solutions Honeywell Security Asia Pacific Honeywell International Inc Jan 2009 www security honeywell com 2009 Honeywell International Inc
7. at may arise in case of failure to follow the specified precautions Indicates the serious damage or Refers to injury or property damage even loss of life that may result that may result from failure to follow from failure to follow instructions instructions E The following symbols denote the points that should be followed by the user Prohibitory meaning the Mandatory meaning you action being referred to should follow the should never be taken instructions indicated AN Warning Warning Do not disassemble at any time may result in property damage or loss of life Do not touch may result in property damage or loss of life 2 Honeywell Co Ltd Safety precautions Keep the product away from moisture contact with moisture or other liquids may cause fire electric shock or malfunction If the panel comes into contact with water unplug the cord immediately to avoid electric shock or fire Keep the product away from sources of heat to avoid fire or malfunction When the alarm sounds take appropriate measures immediately Intrusion fire or gas leak may lead to hazardous situations J Warning eeoececececeececeeeeceeeeeeseeeeeeces Do not disassemble or modify the product may lead to electric shock fire or malfunction Do not use the product in places exposed to inflammable gases or debris such as propane gas or gasoline may cause explo
8. atically terminated 12 Honeywell Co Ltd Phonecall function Talking to someone at the common entrance Taking calls from the common entrance 1 The common entrance bell rings the guard lamp blinks the image is shown onthe screen 2 Pressing the Guard button causes the guard lamp to light up 3 Talk to the visitor To stop talking press the Guard button You have three minutes to talk to the person at the common entrance before the line is automatically terminated Pressing the button while talking to the entrance or over the telephone causes the entrance door to open A When setting the away mode refer to page 14 the call from the common entrance is automatically connected to the guard post When you get another call while talking to someone over the telephone or interphone you can answer the new call only after terminating the first call HS 6270 User s Manual 13 Security and Alarm Functions Away Mode x Away Mode You can activate the security system when leaving the house 1 Press Away 2 Press The Away lamp and Safety Zone lamp for monitoring are then lit Message Security system is activated Away warning sound of toot toot is then heard During setting the away mode is not set if the security zone except the entrance door and living room is breached or sensed The corresponding safety zone lamp then blinks and the
9. door while the Exit or Sleep mode is activated the security system is disabled during the previously set entrance delay time with the warning alarm toot toot sound Caution If you do not set the Room mode while the warning alarm sounds you are considered an intruder and the security system is activated In Case of Emergency Reporting an Emergency 1 Press the Emergency button on the bottom left 2 The Emergency lamp then blinks Caution Use the a Emergency button only when necessary In Case of Fire or Gas Leakage 1 The Fire or Gas lamp on top blinks the corresponding alarm is issued In Case the Security Alarm is Activated 1 The corresponding safety zone lamp blinks Message Intruder found The security status is transmitted to the guard post HS 6270 User s Manual 15 Security and Alarm Functions Deactivating the Emergency Alarm 1 Enter the password 2 To turn off the warning sound press the stop button 3 To deactivate the alarm completely press the return amp button a You need to finish your call or monitoring first to deactivate the alarm while talking onthe phone or monitoring the entrance Caution Ifthe gas leak or cause of fire is not removed completely the alarm is activated again ED Incase of gas leak close the gas valve open the windows to allow ventilation and wait until the sensor lamp turns green Do not turn on any elect
10. fety zone lamp goes out To goto another function setting menu press FY Toend the function setting menu press the button Ca The zone setting is not affected even though alarm function or away mode and or sleep mode is deactivated 8 Honeywell Co Ltd Function Setting Setting changing and checking the exit entry delay Xx You can set the delay time for activating your security system for exit entry Xx Exit Delay refers to the time given by the system to let you exit the house before the system is activated Xx Entry Delay refers to the time given by the system to let you deactivate the system after entering the house X Optional function may not be available in some models Setting and changing the entry exit delay Press the Press the button Press Q G Number X 15 sec immediatelhy 4 min To save the desired setting Initially set to 30 sec Ifdesires to input again start with the step 3 If desires to confirm the time start from the step 3 of Checking the entry exit Press J to enter other menu setting Toexit the function setting mode press the button If the delay is set to 0 the alarm system is activated immediately after setting the away mode ex setting entry exit delay to 1 min Checking the entry exit delay A Press the button Press 3 Press the J button to hear the saved entry exit delay time through the
11. he guard post and common entrance Door Button Lamp Used when talking to someone at the door X The location of the lamps and specifications may vary by model 6 Honeywell Co Ltd Function Setting Adjusting the Volume of the Bell Press the O button Press Press low E medium or high to adjust the volume level Toendthe function setting menu press the button Adjusting the Brightness of the Screen Press the button Press B Press dark amp medium or bright to adjust the brightness level Togoto another function setting menu press B Toendthe function setting menu press the button Adjusting the Volume of the Phone Press the button Press Press local door guard post J common entrance or interphone Press small large Toend the function setting menu press the O button _ The volume is set to medium level when released HS 6270 User s Manual 7 Function Setting Setting the Safety Zone x When activating the security system you can set the Safety Zone Press the 8 button 3 Press 8 Press 9 Safety Zone 1 Safety Zone 2 Safety Zone 3 or Q Safety Zone 4 then the corresponding safety zone lamp blinks Press it again to turn off Pressing the corresponding safety zone button causes the safety zone to be set not monitored safety zone lamp blinks monitored sa
12. instructions 2 Make sure that the product is impervious to volatile gases to avoid sounding the fire alarm by mistake 3 In case of product breakdown do not disassemble the body or sensor Contact the vendor 4 In case the main panel goes out of order contact the vendor 5 Use the emergency button only when necessary 6 The product does not function during blackout or in case the circuit breaker is shut down 7 To clean the product use a soft cloth Do notuse volatile liquids i e benzene thinner or wet cloth to clean the product HS 6270 User s Manual 5 Parts of HS 6270 Parts of the control panele ee oeoeceocoocoocooooooooooo Fire Gas Lamp LCD Signals a fire gas alarm Shows an image of the entrance FunctionLamp Safety Zone Lamp Indicates the functionsettingstatus Indicates the Safety Zone and Burglar Alarm states Power Lamp A B IL Stay Lamp way Button Lamp Indicates the stay setting status Sets your home to away mode and indicates that the 10KEY stop reset button system is in away status Used when inputting numbers for dialing function setting enterin Speaker the eee i i EMERGENCY Hons swell Emergency Button Lamp Used in case of emergencies indicates the Microphone emergency status Talk Button Lamp Test Function open Used when talking over the telephone Opens the door to the and interphone entrance or common Guard Button Lamp entrance Used when calling t
13. n Information Event 1 If there is new information the content will display automatically for 3 seconds on the menu and the melody will ring at same time 2 After the auto display the FUNCTION light will flash continuously to inform that the new information reaches 3 If checks the information in one minute and press J the menu will turn off HS 6270 User s Manual 17 Saving Image Function To Modify Time 1 Press Door to go to SET UP MODE in Time Modify 2 Press to remove the cursor to the modify position 3 Press to increase the value press amp to decrease the value After the time check press to remove the cursor to the position to modify 4 To exit fromTime Setup Mode press 1 When the visitor is calling at entrance or pressing the entrance monitor press tostart recording 2 When Away Mode is set but the visitor calls at entrance it will record automatically X The recorded image is in color style When the amount of the images is over 50 pieces the 51st one would cover the first one the 52nd one would cover the second one so does the following one 12009204 06 10 00 30 To Check the image To Delete the image 1 Press Door to display the 1 Press Door E to display the recorded image recorded image 2 Press J to delete the all saved 2 Press to display the next menu images 2009204 06 10 00 30 18 Honeywell Co Ltd
14. or J 2 The door lamp blinks the image is shown on the screen monitoring To stop monitoring press Door fi You have 30 seconds to monitor the door before it is automatically terminated HS 6270 User s Manual 11 Phonecall function Interphone function Answering the interphone 1 The interphone bell rings the talk lamp blinks 2 Pressing the Talk button causes the talk lamp to light up 3 Talk to the person on the other flat Making a call over the interphone 1 Press the Talk button 2 You will hear the dial tone after pressing the button 3 Press the address number of the flat you want to call ex Making a call toApt no 101 flatnumber 1004 gt Talk G 000 0 0000 0 Tohang up press the Talk button You have three minutes of talk time before the line is automatically terminated Ca In case you get a call from the telephone and interphone atthe same time press the Talk J button to be connected to the telephone Reaching the guard post Taking calls from the guard post 1 The guard post bell rings the guard lamp blinks 2 Pressing the Guard button causes the lamp to light up 3 Talk to the guard How to reach the guard post 1 Pressing the Guard button causes the lamp to light up 2 Talk to the guard Tohang up press the Guard button You have three minutes to complete your call before the line is autom
15. rical device x You can perform deactivating and resetting by pressing stop and return even while the gas or fire alarm is activated according to the laws and regulations on fire prevention Testing the Alarm Sound Press the O button Press Press for emergency for fire for gas or for intrusion The lamp then blinks and the corresponding alarm sounds in case of emergency however only the lamp blinks To turn off the warning sound press stop Fy To terminate the test press return 16 Honeywell Co Ltd Electronic Bullet Board Function Electronic Bullet Board Function View Info Title 1 Press the button and then press to display the information title 2 The title shows 20 letters atthe first part of the information View Info Content 1 Press the No 9 O onthe title menu of the information 2 To select the 10th one on the Information No Press 3 Itdisplays Loading at first during reading the information then turn to the menu finally the information content 4 The reading time depends on the length of the information 220 letters need about 10 seconds Return the information content to the title content 1 To return to the title menu press End the Information Menu 1 To end the information menu and exit press button or amp tauto ends after 30 seconds without pressing any butto
16. sion or fire Check the gas sensor monthly Replace it after 4 years Malfunction may result in hazardous situations Replace the fire sensor every 2 years Malfunction may result in hazardous situations HS 6270 User s Manual 3 Safety precautions N Caution ssesecsscccccccccccccccscces Do not use benzene or other volatile Keep out of reach of children substances may damage the product product may cause injury Do not place the product near large Child users should be instructed on TV s or speakers that generate strong the product s proper use Adult magnetic forces supervision is recommended to may cause malfunction avoid injury Do notinstall on an unstable location Do not apply shock or impact to the may get detached and result in product may cause breakdown breakdown or injury Keep away from direct sunlight Donotstore in high temperature areas may cause product deformation or malfunction When the gas leak alarm sounds perform the following steps 1 Close the gas valve immediately and open the windows and doors to secure ventilation 2 Do not unplug or plug in electrical devices 3 Do not open the refrigerator 4 When the gas is completely removed check the gas appliance 4 Honeywell Co Ltd Usage suggestions To get the best use of the product take note of the following 1 When using the gas alarm and or fire sensor follow the manufacturer s
17. the Password Press the E button Press Press Press the button of J E to check the password You will then hear the saved password Tocontinue checking passwords start with the step 3 Toend the function setting menu press the button Ex To check the password saved to 1 gt 9 O E gt The passwordis one one one one 10 Honeywell Co Ltd Phonecall function Telephone function Xx Optional function may not be available in some models Answering the phone 1 The phone bell rings the talk lamp blinks 2 Pressing Talk causes the talk lamp to light up 3 You are now ready talk to the caller Making a phone call 1 Pressing Talk causes the talk lamp to light up 2 Dial the number to make your call To hang up press Talk Talking to someone at the Door Taking calls from the Door 1 The door bell rings the door lamp blinks you can see the door on the screen 2 Pressing Door causes the door lamp to light up 3 Talk to the visitor To terminate the call press Door You have three minutes to talk to the person at the door before the line is automatically terminated When someone calls from the door or if you are using the phone you can open the entrance door by pressing 2 Ca The door opening function is available only when a separate device is installed Monitoring the Door 1 Press Do
18. utton e Amotorcycle or car passing by the doorphone camera may affect the image on the screen 20 Honeywell Co Ltd Product specifications Product specifications The appearance and specific ations in the user s manual may be changed without prior notice for product improvement purposes Electrical specifications and characteristics Classification Control panel Camera Power voltage 220V AC DC 12V Dimensions mm 296 x 205 x 47 120 x 120 x 39 Weight Approx 1100 g Approx 200g Temperature Sill Ona OMe O 40C Surrounding humidity 0 80 0 80 Power Normal 5W 0 2W consumption Maximu 25W 2 4W HS 6270 User s Manual 21 Product warranty Product warranty Model HS 6270 Date of purchase Warranty period Product serial number Store of purchase X This product has gone through strict quality inspections prior delivery Xx hMalfunction during use shall be repaired by the designated service or call center Warranty rules x Malfunctions occurring during normal use and within the warranty period shall be repaired free of charge Xx Malfunctions occurring during normal use and beyond the warranty period shall be repaired for a reasonable fee Xx Malfunctions due to natural disasters shall be repaired for a reasonable fee Date of occurrence Cause of of m