Home

DIN-A-MITE C

image

Contents

1. 4 in 102 mm Clearance for Air Flow and Wire Bending Radius 2 11 in 54 L 5 74 in 146 mm PER NER 5 59 in 142 mm m 1 73in 9 96 i in A OO 44 57 5 17 in 5 89 in 131 150 5 in H Es E 8 408 127 mm 2 3 42 in DIN EN 50022 g i pee 87 mm Rail Release Tal AOO pull down 4 in 102 mm min 1 366 to 1 390 in Q Q Q 4 in 102 mm Clearance for Air Flow and Wire Bending Radius 34 7 to 35 3 mm 490 Front Panel is Touch Safe No Clearance is Required E in 48 mm Allowance for No 8 Fastener M4 Dimensions Fan Cooled DIN rail Panel Mount Side 4 in 102 mm Clearance for Air Flow and Wire Bending Radius 5 74 in 146 mm EN 4 in 102 mm 5 59 142 mm 1 1 73 2 26 44 44 mm 57 mm 589 in 5 17 in 150 mm 131 mm 5 in 7 64 in 127 mm 3 10 in 194 mm 79 mm 4 Rail Release Tab pull down 1 Front Panel is Touch Safe No Clearance is Required 4 in 102 mm min 4 in 102 mm Clearance for Air Flow and Wire Bending Radius Dimensions Natural Convection Through Wall Mount Front
2. control option FO only no more than three inputs connected in series Additional Specifications for Phase Angle Phase Angle with Current Limit and Single Cycle Variable Time Base Operation With control option S single cycle variable time base the output is not on for more than one consecutive AC cycle below 5096 power and not off for more than one consecutive AC cycle above 5096 power Phase angle control single phase only Control Input e Oto 20mA 4 to 20mA to 5VDC 1 to 5VDC and 0 to 10VDC Input impedance 2500 for 4mA to 20mA 5 for linear voltage input Output Voltage 100 to 120VAC 200 to 208VAC 230 to 240VAC 277VAC 400VAC 480VAC and 600VAC 10 Linearity Control Option S e 5 input to output power over 0 to 10096 of span between calibration points Linearity Control Options P and L e 5 input to output power as referenced to a sinusoidal power curve between calibration points Resolution Better than 0 196 of input span with respect to output change Soft Start Control Options P and L Typically e 5 seconds soft start on power up e Soft start on thermostat overtemperature Soft start on 1 2 cycle drop out detection 1 second soft start on set point change Options e Manual control kit 1 potentiometer 08 5362 e Alarm option is not available on control options P or L Specifications are subject to change without notice Output Rating Curves DIN A MITE Style
3. accept 24 to 16 AWG 0 2 to 1 5 mm wire e Torque to 4 4 in Ib 0 5 Nm max with a 1 8 in 3 5 mm blade screwdriver Line and Load Terminals Compression will accept 14 to 3 AWG 2 5 to 25 mm wire Torque to 24 in Ib 2 7 Nm max with a 1 4 in 6 4 mm blade screwdriver or a type 1A 2 Pozi driver Operating Environment e See the output rating curve chart on next page 0 to 9096 RH relative humidity non condensing Storage temperature 40 to 185 F 40 to 85 C Operating temperature 29 to 176 F 34 to 80 C Insulation tested to 3 000 meters DIN Rail Mount DIN EN 50022 35 mm by 7 5 mm Back Panel Mount Four mounting holes No 6 to No 8 M3 to M4 fastener Through Wall Mount e See page 4 for through wall panel cutout Note Mount cooling fins vertically Additional Specifications for Contactors and Time Proportional Controllers Control Mode Zero Cross e Control option C VDC input contactor output e Control option K VAC input contactor output e To increase service life on contactor models the cycle time should be less than three seconds e Control option 4 to 20mA DC input variable time base control output Control Input e AC contactor 24VAC 10 120VAC 10 25 240VAC 10 25 25mA max per controlled leg e DC contactor 4 5 to 32VDC max current 4 5VDC is 6mA per leg add 2mA per LED used to the total current Loop powered linear current 4 to 20mA DC loop powered
4. control options L P and S Alarms zero cross models only Shorted SCR Alarm Option Alarm state when the input command signal is off and a 10A or more load current is detected by the current transformer two turns required for 5A and three turns for 2 54 Open Heater Alarm Option Control Option S only Alarm state when the input command signal is on and the load current detected by the current transformer is 2096 less than customer adjusted set point Alarm Output Energizes on alarm non latching Triac 24 to 240VAC external supply with a current rating of 300mA 77 F 25 200mA 122 F 50 100mA 176 80 and a holding current of 200pA with a latching current of 5mA typical Agency Approvals CE with proper filter 204 108 EC electromagnetic compatibility directive EN 61326 1 industrial immunity Class A emissions not suitable for Class B environments Phase angle and phase angle with current limit control options P and L are not CE approved for conducted or radiated emissions 2006 95 EC low voltage directive EN 50178 safety requirements installation category Ill pollution degree 2 e UL 50 Type 4X enclosure Class 1 Div 2 per ANSI ISA 12 12 01 Through wall heat sink models T4 File 184390 e Gs UL 508 listed and C UL File E73741 LISTED e 2011 65 EU RoHS 2 e Shock and vibration tested to IEC 60068 2 32 Vibration tested to IEC 60068 2 6 Control Input Terminals Compression will
5. 20A 0808 0325 0020 DFJ 20 0808 0325 0030 DFJ 30 0808 0325 0040 DFJ 40 0808 0325 0050 DFJ 50 63A 0808 0325 0060 DFJ 60 80A 0808 0325 0080 DFJ 80 100A 0808 0325 0100 DFJ 100 Fuse Holder Part Number Cooper Bussman Fuse Rating 20 and 30A 0808 0326 1530 CH30J1i 40 to 63A 0808 0326 3560 CH60J1i 80 and 100A 0808 0326 7010 J601001CR Ordering Information Part Number GIG Cooling Line amp amp Current Load Custom Rating Leg ETSI Options D C Control Phase 1 phase 1 controlled leg 4 5 to 32VDC input contactor output 2 3 phase 2 controlled legs RO 4 to 20mA DC input variable time base output 3 phase controlled legs use with four wire wye 1 22 to 26VAC input contactor output 8 2 independent zones control options C K K2 100 to 120VAC input contactor output 9 3 independent zones control options C K3 200 to 240VAC input contactor output L 0 to 5 Phase angle output with current limiting single phase Cooling and Current Rating per Leg see chart below only 0 Natural convection standard DIN rail or panel heat sink 0 to 5 Phase angle output single phase only 12 Fan cooled 120VAC standard DIN rail or panel heat sink S 0 to 5 Single cycle variable time base output 2 Fan cooled 240VAC standa
6. C Ratings at 100 On 0007 oa o Max Internal Enclosure Ambient Temperature B Pha g oa 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Current Amperes into a Resistive Load a DIN A MITE Style C Ratings at 100 On E ou Fan Cooled I N ao ua a o Rocco s s oo o a Max Internal Enclosure Ambient Temperature C e a 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Current Amperes into a Resistive Load DIN A MITE Style C Ratings at 100 On Recommended Max o 75 70 65 Enclosure Temperature is 176 F 80 C 55 50 40 35 30 25 EET TEL LTTE a EET EET TITT T TTTTTTTTT 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Current Amperes into a Resistive Load Ambient Air Around Heatsink Fins Dimensions Natural Convection DIN rail Panel Mount Front Side 1 51 in 38 mm L 1 81 in 46 mm grid iudi
7. DIN A MITE C The DIN A MITE C silicon controlled rectifier SCR power controller provides a low cost compact and versatile solid state option for controlling electric heat This controller is designed and manufactured with the quality features expected from Watlow DIN rail panel mount and through wall mount versions are available Features include single phase three phase two leg and three phase three leg 24 600VAC operation Current Switching capabilities range from 30 to 80A depending on the model ordered Variable time base linear voltage and current process control or VAC VDC input contactor versions are available Single phase phase angle firing and current limiting are also available All options are model number dependent and factory configurable This power controller includes 200KA short circuit current rating SCCR tested up to 480VAC to minimize damage in the event of a short circuit when used with required fusing 2015 Watlow Electric Manufacturing Company all rights reserved SCR Power Controller Delivers Up To 80 Amperes in a Compact Package Features and Benefits 200KA SCCR with proper fusing Minimizes damage in the event of a short circuit DIN rail panel and through wall mounting Provides versatility and quick low cost installation Compact size Reduces panel space and cost Touch safe terminals ncreases safety for installer user One and three phase power e Can be used
8. Models DC1 L P 0 EL I IY V V V Phase angle control control options L and P is infinitely variable over the period of the AC sine wave It provides a variable voltage and or current output The phase angle circuitry is transformer powered and accepts a linear voltage current or potentionmeter input Single Cycle Variable Time Base Output Models DC S 25 Power Output 1 AC cycle on 3 cycles off B E 50 Power Output 1 AC cycle on 1 cycle off LL With single cycle variable time base control at 50 percent power the output is on for one cycle and off for one cycle At 25 percent it is on for one cycle and off for three cycles Under 50 percent the output is not on for more than one consecutive cycle over 50 percent the output is not off for more than one consecutive cycle Semiconductor Fuses for Applications through 600VAC Fuse Part Number Watlow Cooper Bussman 40A 17 8040 FWP 40A14F 50A 17 8050 FWP 50A14F 63A 17 8063 FWP 63A22F 80A 17 8080 FWP 80A22F 100A 17 8100 FWP 100A22F Fuse Holder Part Number Ferraz Shawmut Fuse Rating 40A 17 5114 US1411 50A 17 5114 051411 63A 17 5122 082211 80 17 5122 082211 100 17 5122 082211 Combined Branch Protection and Semiconductor Fuses for Applications through 480VAC Fuse Part Number Fuse Rating Cooper Bussman 125 of Load
9. Top __ 8 ea 5 0 8 x 10 mm 255m 4 in 102 mm Min M5 Internal Tooth Lock Washers 57 mm Clearance for Air Flow Included utside Top and Bottom M 81 in 122 mm Any Gauge UUU 4 50 in 114 mm 2 17 in 55 mm r Bo pesce e Lug Inside Pinche ST 2 8 12 Outline F d i Sheet Metal 12 Ga Front Panel is Touch Safe N 7 in 178 mm No Clearance is Required g i e el 9 9 9 le j e e 0 4 in 10 mm Min ae Clearance for Air Flow Both Sides With the potential for high through wall heat sink temperatures application may require a touch safe shield Top 5 74 in mm Panel Cutout Ground Wire Entry Drill 0 228 in 5 8 mm 8 Typical Panel Opening Heat Sink Outline 0 375 in 9 5 mm Reference 1 0 425 in 10 8 mm 105 1 mm pH 1 625 in 41 3 mm 6 375 in LH H 3 161 9 mm 4 625 in 117 5 mm 5 850 in 148 6 mm t 24 1 0 338 in 8 6 mm Reference 0 275 in 7 0 mm 1 034 in 26 3 mm 3 103 in 78 8 mm 3 862 in Extended Heater and Power Controller Life with Variable Time Base With variable time base control the power controller automatically adjusts the time base and output power with respect to the command signal Accelerated life testing shows that variable time base contr
10. emarks of Watlow Electric Manufacturing Company UL and C UL are registered trademarks of the Underwriter s Laboratories Inc Cooper Bussmann is a registered trademark of Cooper Bussmann Inc To be automatically connected to the nearest North American Technical Sales Office 1 800 WATLOW2 www watlow com inquiry watlow com International Technical Sales Offices Australia 61 3 9335 6449 China 86 21 3532 8532 France 33 0 1 41 32 79 70 Germany 49 0 7253 9400 0 India 91 40 6661 2700 Italy 39 02 4588841 Japan 81 3 3518 6630 Korea 82 2 2169 2600 Malaysia 60 3 8076 8745 Mexico 52 442 256 2200 Singapore 65 6773 9488 Spain 34 91 675 1292 Taiwan 886 7 288 5168 United Kingdom 44 0 115 964 0777
11. in a variety of applications Open heater shorted output alarm Notifies the user in case of an open heater or shorted output Mercury free Assures environmental safety Faster switching with solid state e Saves energy and extends heater life UL 508 listed C UL RoHS 2 and CE with filter Meets applications requiring agency approval Reduces end product documentation cost System solution component Provides single source thermal loop Back to back SCR design Ensures a rugged design Registered Company Winona Minnesota USA WATLOW WIN DMC 0115 Specifications Operator Interface Control input and indication light Alarm output and indication light Current limit indication LED Amperage Rating See output rating curves on the next page Max surge current for 16 6ms 1 350A peak Max 121 for fusing is 9100A2s Latching current 200mA min Holding current 100mA min Fan current 0 14A for 24VDC 0 12A for 120VAC 0 06A for 240VAC Off state leakage 1mA at 77 F 25 C max e Power dissipation 1 watt per ampere per leg switched e 200KA SCCR Type 1 and 2 approved with the recommended fusing see user manual Line Voltage e 24 to 48VAC units 20 4VAC to 53VAC max e 100 to 240VAC units 48VAC min to 265VAC max e 277 to 600VAC units 85VAC min to 660VAC max 100 to 120VAC 200 to 208VAC 230 to 240VAC 277VAC 400VAC 480VAC 600VAC 10 15 50 to 60Hz independent 5
12. ol significantly reduces expansion and contraction of the heater element This extends heater and power controller life while improving process temperature control This saves money on heaters downtime and maintenance Loop Powered or Transformer Powered Loop Powered By using a temperature controller s 4 20mA process output signal as the power supply for the DIN A MITE input the cost of the power controller can be reduced With control option FO the 4 20mA control signal simultaneously powers the DIN A MITE s internal electronics and provides the input command signal Transformer Powered DIN A MITE controllers with single cycle variable time base or phase angle outputs control options L P and S detect the power line zero cross with a transformer that also powers their internal electronics These units can be controlled manually with a potentiometer or automatically with a temperature controller using any of the control options 4 20mA linear voltage 0 5 1 5 and 0 10VDC Loop Powered Variable Time Base Output Models DC FO0 20 Power Output 3 AC cycles on 12 cycles off AA VVV AM VVV 50 Power Output 3 AC cycles on 3 cycles off AA ANN MA AM AM VVV VVV VVV VVV VVV 80 Power Output 12 AC cycles on 3 cycles off AANANAANAAAR VAVVVVVVUNVV With loop powered variable time base control the minimum on or off time is three cycles Phase Angle Output
13. rd DIN rail or panel heat sink 0 4 to 20mA input cooled 24VDC standard DIN rail or panel heat sink 1 12 to 20mA input option S only T Natural convection through wall or cabinet heat sink NEMA 4X 2 0 to 20mA input ONG Line and Load Voltage 0 to SVDC input 02 24 to 48VAC control options C F 12 100 to 120VAC control options L P S input 20 200 to 208VAC control options L P S Not CE approved for conducted or radiated emissions 24 100 to 240VAC control options C F 230 to 240VAC control options L P S 27 277VAC control options L P S 0 No alarm 40 400VAC control options L P S S Shorted SCR alarm not available with control options L or P 48 480VAC control options L P S Open heater and shorted SCR alarm control option S only 60 277 to 600VAC control options C F 600VAC control options L P S User Manual English 1 German Spanish French Custom Options 00 Standard part 1X 1 second soft start control options P L XX Any letter or number custom options labeling etc DIN A MITE C Current Rating Table Current at 122 F 50 C a WV PO PO PO 0 es e Watlow and DIN A MITE are registered trad