Home

Line Seiki

image

Contents

1. mus um DD hh The Year Month Day Hour or Minute values can be incremented by pressing 1 2 3 4 or 5 Holding down 1 2 3 4 or 5 will continuously increment these values respectively Press F to leave the Date amp Time Setting Mode Note x Editing of Date amp Time is disabled when accessed from Recording Mode F KEY Device ID Setting Hold down F and press 2 to enter the Device ID Setting Mode The display will show the Device ID a 3 digit user programmable number which is used to identify different DK 5000 devices ot m m m Dui al E Holding down 3 4 or 5 will continuously increment each digit Press F to leave the Device ID Setting Mode Each digit of the Device ID can be incremented by pressing 3 4 or 5 Note Editing of Device ID is disabled when accessed from Recording Mode or when there is an active connection to the companion software Memory Recall Hold down F and press 3 to enter Memory Recall Mode The display will show the Memory No and Timestamp of the newest Record saved EM 000 art n wm me p cut om Lt og I wy m o th ea If there is no Record available the display will show no data nf dRkA Press Press Press Press Press Press Memory All Clear When in Memory All Clear Mode the display will show the All Clear options 1 to display the next Record 2
2. to display the previous Record 3 to toggle Timestamp Display mode 4 to toggle Input Value Display mode 5 to enter Memory All Clear Mode F to leave the Memory Recall Mode ax rs oe mh Lr YE5 ond Hold down 4 for 1 second to select Yes All Records will be deleted and device will return to Memory Recall Mode no data will be displayed While clearing the memory device will show All Data to Clear ALL REA ta bn Press 5 to select No No Record will be deleted and the device will return to Memory Recall Mode Press F to leave Memory All Clear Mode Note x Memory All Clear Mode is disabled when Recording Mode is active Make sure to keep the device powered while clearing memory or deleting Records to avoid risk of data corruption KEY Start End Record While in Standby Mode hold down for 1 second to start recording of data A Record will be created with corresponding Start Timestamp The device will enter Recording Mode and logging is enabled The display will show 0 number of inputs 1 The Record will be a collection of data logs composed of input Timestamps which will be saved on every press of input keys While in Recording Mode hold down for 1 second again to end recording of data The Record will be terminated and saved with corresponding number of inputs and End Timestamp 2 The Memory No indicated by MEM will inc
3. up routine blinking all LCD segments for 2 7 seconds After the start up routine the device will proceed to Date amp Time Setting Mode to set the device Date amp Time See KEY OPERATION for details mX Important Calendar clock will not update when there is no power supply available Make sure that there are batteries installed before disconnecting both DC jack and USB power supply to maintain calendar clock function When DC jack or USB power is connected power is not supplied from the batteries and battery charge will not be drained When operating only on batteries Alkaline type batteries can provide at least up to 200 hours of operation under normal operating condition G_4 icon will appear on the upper right corner of the display to indicate a low battery condition G 4 icon will blink continuously under following conditions gt when battery is almost empty gt when no battery is installed while the device is powered by DC jack and or USB If all power supplies are removed the last device Date amp Time will be stored in a temporary memory If device is in Recording Mode Record will be saved When the device is powered ON again it will resume operation in Date amp Time Setting Mode using the last saved Date amp Time values See KEY OPERATION for details E OPERATION MODES This device has four main operation modes namely Standby Mode Recording Mode 3 SettingMode 4 Memory Recall Mode Standby Mod
4. DK 5000 SERIES MANUAL INSTRUCTION MANUAL DK 5005B Thank you for purchasing our product DK 5005B Please confirm that you have the correct device by checking the product label Please read this instruction manual carefully before using this device to ensure correct usage Please keep this instruction manual for future reference E INTRODUCTION DK 5005B is an input device which logs timestamp of five 5 input keys It can save records in its memory and has a built in calendar clock for timestamp Its five input keys can be used to monitor different types event attribute or classification mX Important This device requires DK 5000 Mieruzzo Software to view record details The software runs on Windows 7 8 or 8 1 OS Please use a micro B to A USB cable to connect the DK 5005B device to a computer The companion software enables user to download delete and save data from the device to a computer The software also enables real time display of the device on a computer li POWER SUPPLY The device can be powered through three power supply options The list below shows the power supply options according to priority of usage gt 5 5mm DC Jack 9V 50mA X gt USB Power 5V 100mA gt 4pcs AAA Battery X Please use Line Seiki AC DC Power Adapter for DK 5000 sold separately to power the device via DC jack Upon initial connection to a power supply or resumption of power the device will perform the start
5. ata to a XLS or CSV file delete records stored in the device sync device time to computer system time change Device ID The software also has an Auto Acquire function which enables real time display of the number of inputs displayed on the device The display is updated every 1 second Please refer to the DK 5000 Mieruzzo Software User Manual for more details When the device is connected to the software the icon will appear on the upper right corner of its display E LABELS D Shite SUB a e sees 8988 8898 8899 8888 BAAB DK 5000 Series Clock Memory No Display Key Input Display Input Key Date Time Icon Subtract Key Subtract Icon Strap Hole Battery Warning Icon Function Key Software Link Icon 4 USB 2 0 Port 5 5 mm DC Jack Total Inout Displ Power Key ap Total apie Display E KEY OPERATION POWER KEY Power On Off To switch ON hold down POWER for 1 second The default power up display is Standby Mode showing the text Standby on the display To switch OFF hold down POWER for 3 seconds When switching off from Recording Mode the Record will be ended and saved before switching off F KEY Date amp Time Setting Hold down F and press 1 to enter the Date amp Time Setting Mode The display will show the Date and Time value in the format below YYYY MM DD hh mm gM tt x 3 5g
6. ds on the device memory Memory Recall Mode is indicated by MEM icon and the 4 digit Memory No shown on the upper left side of the display WEN og mn Ma m m Z a ent E itt og a is yyy mm DD mm Please note that misuse of this device may lead to injury to the user or damage to the device Please observe all safety precautions and warnings in ATTENTION this instruction manual Customer Service E LINESHKI CO OD Head Office 37 7 Chuo cho 2 Chome Meguro ku Tokyo JAPAN 152 0001 Contact TEL 03 3716 5151 FAX 03 3710 4552 E mail webtrade line co jp URL http www lineseiki com Memory No represents the memory location of the Record displayed When a Record is deleted the memory location of each Record shifts and Memory No is changed accordingly There are two display modes available for viewing stored Records a Timestamp Display b Input Value Display Timestamp Display mode will show the date and time when the Record is saved Input Value Display mode will show the number of individual inputs and the total inputs Memory Recall Mode also provides an option to clear all Records saved in the device memory See KEY OPERATION for details E SOFTWARE This device works with DK 5000 Mieruzzo Software The software is downloadable for free from the Line Seiki website The software enables the user with the following functions download the data from the device export the downloaded d
7. e This is the default operation mode Standby Mode is indicated by the displayed text Standby The TIME icon and the current time is also shown on the upper left side of the display rE 0B Sind bY Logging of input key press is disabled in this mode By pressing the corresponding key combination of F with 1 2 or 3 other operation modes can be accessed from Standby Mode By holding down Recording Mode can be enabled See KEY OPERATION for details Recording Mode Recording Mode is indicated by the displayed number of inputs for each input key and the total inputs The TIME icon and the current time is also shown on the upper left side of the display Fg 24S 5689 890 OMB Oe Logging of input key press is enabled in this mode The number of inputs for each input key and the total inputs are updated with every press of corresponding input key By pressing the corresponding key combination of F with 1 2 or 3 other operation modes can be accessed from Recording Mode By holding down Standby Mode can be enabled See KEY OPERATION for details Setting Mode There are two Setting Modes a Date amp Time Setting b Device ID Setting When accessed from Standby Mode Date amp Time and Device ID can be viewed and edited respectively When accessed from Recording Mode editing is disabled See KEY OPERATION for details Memory Recall Mode This mode enables viewing of all saved Recor
8. mps are saved per record MEM A memory low indicator Lg will be blinking twice every 5 seconds when the size of memory used is 80 or more mem Amemory full indicator En _ will be blinking when 100 of memory is used m X Important When memory is full starting a new Record will erase the oldest Record to free up memory space for the new Record created Location of Records will shift and Memory No will change accordingly When memory is full and device is in Recording Mode saving a new log that requires additional memory space will erase the oldest Record to free up memory space While erasing a Record the device will show a Record Data to Clear message and logging of input key press is temporarily disabled E SPECIFICATIONS Count Range Display 4 Digit 0 9999 Internal 5 Digit 0 99999 Total Count Range 6 Digit 0 999999 Operating Temperature 0 C 50 C non freezing Operating Humidity 35 85 RH non condensing Storage Temperature 10 C 60 C non freezing Dimension 70 H x 170 W x 25 D mm Weight Approx 130g accessories not included Compliance CE RoHS For more details please visit our website at http www lineseiki com Z ATTENTION Operation Do not use this device near machines that emit strong electromagnetic fields or objects that store static electricity Do not drop or subject this device to strong impact Do not use or store this de
9. rement by 1 everytime a new Record is saved 3 While saving the display will blink twice showing the Memory No and corresponding Timestamp then the count values saved oag me me ry an ro ant i st Ja I kh yyy kes 45 AI 8S AHAA wie 4 After saving the device will enter Standby Mode and data recording is disabled Ome 0B Sind bY Note The Record End Timestamp will be used to identify Records in Memory Recall Mode and as Record Name when data is downloaded on the companion software INPUT KEYS Recording Mode While in Recording Mode press 1 2 3 4 or 5 to enter an input Timestamp and increment the number of inputs TE to caa og IHS goes Go Hao mi 3524 Note Make sure to push the input keys properly to avoid missed input SUB KEY Recording Mode Hold down SUB and press 1 2 3 4 or 5 to decrement the number of inputs at Setting Mode Hold down SUB and press 1 2 3 4 or 5 to decrement values being edited such as Year Month Day Hour Minute or Device ID digit values to Holding down SUB and also holding down these keys will continuously decrement the values being edited Note While SUB is held down the SUB icon will appear on the upper right corner of the display Hi MEMORY CAPACITY The device memory can save up to 250 records which is achieved when only a maximum of 192 Timesta
10. vice where it will be exposed to water or in places with wet conditions Do not use or store this device where it can be exposed to high temperature and high humidity See the battery case markings to ensure that the batteries are properly installed Do not attempt to disassemble or modify this device When using the device via USB power avoid excessive movement to ensure that the device will not be disconnected and power will not be lost The unit is shipped with protective seal on the display This manual was last revised May 1 2015 4DK5002A Contents are subject to change even without prior notice All Rights Reserved Copyright 2015 LINE SEIKI CO LTD