Home
HIKVision IR Speed DOME PTZ Camera User Manual
Contents
1. ON OFF OFF OFF 25 ON OFF OFF ON ON OFF OFF OFF 26 OFF ON OFF ON ON OFF OFF OFF 27 ON ON OFF ON ON OFF OFF OFF 28 OFF OFF ON ON ON OFF OFF OFF 29 ON OFF ON ON ON OFF OFF OFF 30 OFF ON ON ON ON OFF OFF OFF 31 ON ON ON ON ON OFF OFF OFF 32 OFF OFF OFF OFF OFF ON OFF OFF 33 ON OFF OFF OFF OFF ON OFF OFF 34 OFF ON OFF OFF OFF ON OFF OFF 35 ON ON OFF OFF OFF ON OFF OFF 36 OFF OFF ON OFF OFF ON OFF OFF 37 ON OFF ON OFF OFF ON OFF OFF 38 OFF ON ON OFF OFF ON OFF OFF 39 ON ON ON OFF OFF ON OFF OFF 40 OFF OFF OFF ON OFF ON OFF OFF 41 ON OFF OFF ON OFF ON OFF OFF Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual DIP Switch SW1 Settings 42 OFF ON OFF ON OFF ON OFF OFF 43 ON ON OFF ON OFF ON OFF OFF 44 OFF OFF ON ON OFF ON OFF OFF 45 ON OFF ON ON OFF ON OFF OFF 46 OFF ON ON ON OFF ON OFF OFF 47 ON ON ON ON OFF ON OFF OFF 48 OFF OFF OFF OFF ON ON OFF OFF 49 ON OFF OFF OFF ON ON OFF OFF 50 OFF ON OFF OFF ON ON OFF OFF 51 ON ON OFF OFF ON ON OFF OFF 52 OFF OFF ON OFF ON ON OFF OF
2. controlled broken Problem Possible Reasons To Solve the Problem dome can tightly be 2 RS485 or RS485 wire is 2 Change a RS485 wire but not 3 The speed dome is too far away smoothly from the remote control device 3 Add a terminal resistor 4 Too many speed domes are connected 4 Add a RS485 distributor Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Appendix 5 24VAC Wire Gauge amp Transmission Distance The following table describes the recommended max distance adopted for the certain wire gauge when the loss rate of 24VAC voltage is less than 1096 For the AC driven device the maximum voltage loss rate is 1096 allowable For example for a device with the rating power of 80VA which is installed at a distance of 35 feet 10m away from the transformer then 0 8000mm is reguired as the minimum wire gauge Distance Wire Gauge Es d 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56 17 90 27 143 43 362 110 60 47 14 75 22 119 36 301 91 70 40 12 64 19 102 31 258 78 80 35 10 56 17 89 27 226 68 90 31 9 50 15 79 24 201 61 100 28 8 45 13 71 21 181 55 110 25 7 41 12 65 19 164 49 1
3. l e PS DUE Figure 3 5 Wall Mount Corner Adapter A corner adapter has to be used together with a wall mount for corner mounting applications Duces Figure 3 6 Corner Adapter Mounting Accessories Figure 3 7 Hex Screws M8x30 Nuts Spring Washers and Flat Washers Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual 3 2 2 Corner Mounting 1 Install the corner adapter Steps 1 Drill four holes in the corner according to the screw holes of the corner adapter and then insert M8 expansion screws not supplied into the holes 2 Pull the power line video cable and control line through the center hole of the corner adapter 3 Attach the corner adapter to the corner by aligning the 4 screw holes of the corner adapter with expansion screws on the corner 4 Secure the corner adapter to the corner with the nuts and washers to tighten the four expansion screws Nuts and Washers Figure 3 8 Install the Corner Adapter Note Make sure that the cables have enough length For outdoor applications please apply the sealant around the center hole for waterproof 2 Attach the gasket then the wall mount to the corner adapter 3 Secure the wall mount to the corner adapter with 4 hex screws and spring washers Note When tightening the screw it is better to compress the spring washer tightly first and then
4. 6 Long arm Wall Mount Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Appendix 3 Bubble Maintenance The bubble is a transparent plastic The dust oil and finger print etc will cause scratch or image blur Please refer to the following method to clean the bubble Handling dust Use oil free soft brush or blowing dust ball to clean the dust Handling oil Steps 1 Wipe off the water drop or oil by soft cloth and dry the bubble 2 Use oil free cotton cloth to wipe the bubble with alcohol or detergent 3 Change the cloth to wipe the bubble until the bubble is clean Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Appendix 4 RS485 Bus Connection General Property of RS485 Bus According to RS485 industry bus standard RS485 is a half duplex communication bus which has 1200 characteristic impendence the maximum load ability is 32 payloads including controller device and controlled device RS485 Bus Transmission Distance When using 0 56mm 24AWG twisted pair line according to different baudrate the maximum transmission distance theory table is shown as below Max Distance of RS485 Transmission Baudrate Max Distance 2400BPS 1800m 4800BPS 1200m 9600BPS 800m The transmission distance will be decreased if we use the thinner cable or use this product under the strong electromagnet
5. Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Figure 3 22 Install the Dome Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Appendix Appendix 1 Lightning amp Surge Protection This product adopts TVS plate lightning protection technology to avoid damage caused by pulse signal that is below 3000W like instantaneous lighting stroke surging etc According to the actual outdoor situation necessary protection measures must be taken besides ensuring the electrical safety The distance between signal transmission wires and High voltage eguipment or high voltage cable is at least 50m Outdoor wiring should better be routed under eaves as much as possible In the open field wiring should be buried underground in sealed steel pipe and the steel pipe should be one point grounding Overhead routing method is forbidden In strong thunderstorm area or high induction voltage areas such as high voltage transformer substation high power lightning protection apparatus and lightning conductor are necessary to be added The design of lightning protection and grounding of the outdoor devices and cables should be considered together with the lightning protection demand of buildings It also must conform to the related national standards and industrial standards The system should be eguipotential grounded The grounding eguipment must conform to the
6. FCC Information FCC compliance This eguipment has been tested and found to comply with the limits for a digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the eguipment is operated in a commercial environment This eguipment generates uses and can radiate radio freguency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this eguipment in a residential area is likely to cause harmful interference in which case the user will be reguired to correct the interference at his own expense FCC Conditions This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation EU Conformity Statement and comply therefore with the applicable harmonized European standards listed under the Low Voltage Directive 2006 95 EC the EMC Directive 2004 108 EC the RoHS Directive 2011 65 EU C 4 This product and if applicable the supplied accessories too are marked with CE 2012 19 EU WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supp
7. rotate it half turn for water proof without damaging the threads Figure 3 9 Install the Wall Mount Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual 4 Install dome to the mount Please refer to Section 1 2 Installation and Cabling for installation details Figure 3 10 Finish the Installation 3 3 Pole Mounting Applications 3 3 1 Components Wall Mount Figure 3 11 Wall Mount Pole Adapter A pole adapter has to be used together with a wall mount for pole mounting applications Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Figure 3 12 Pole Adapter Pole Mounting Hoops Pole mounting hoop is used for pole mounting with pole adapter and wall mount There are following dimensions selectable p59 82mm 84 108mm 103 127mm 130 152mm 155 178mm p180 203mm and 194 216mm Dimensions can be customized according to your demand Note The dimensions of the pole mounting hoop must match with the diameter of the pole adapter Figure 3 13 Pole Mounting Hoops Mounting Accessories Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Figure 3 14 Hex Screws M8x30 and Spring Washers 3 3 2 Pole M
8. 20 23 7 37 11 59 17 150 45 130 21 6 34 10 55 16 139 42 140 20 6 32 9 51 15 129 39 150 18 5 30 9 47 14 120 36 160 17 5 28 8 44 13 113 34 170 16 4 26 7 42 12 106 32 180 15 4 25 7 39 11 100 30 190 14 4 28102 37 11 95 28 200 14 4 39 6 35 10 90 27 Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Appendix 6 Wire Gauge Standards BW ele En IS Cross sectional Gauselmmi Wire Gauge Gauge SWG s of Bare AWG Wire mm2 0 750 21 0 4417 0 800 20 21 0 5027 0 900 19 20 0 6362 1 000 18 19 0 7854 1 250 16 18 1 2266 1 500 15 17 1 7663 2 000 12 14 3 1420 2 500 4 9080 3 000 7 0683 Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie lc TVIRELANDie gt 93 Online Shop Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie
9. F 53 ON OFF ON OFF ON ON OFF OFF 54 OFF ON ON OFF ON ON OFF OFF 55 ON ON ON OFF ON ON OFF OFF 56 OFF OFF OFF ON ON ON OFF OFF 57 ON OFF OFF ON ON ON OFF OFF 58 OFF ON OFF ON ON ON OFF OFF 59 ON ON OFF ON ON ON OFF OFF 60 OFF OFF ON ON ON ON OFF OFF 61 ON OFF ON ON ON ON OFF OFF 62 OFF ON ON ON ON ON OFF OFF 63 ON ON ON ON ON ON OFF OFF 64 OFF OFF OFF OFF OFF OFF ON OFF 65 ON OFF OFF OFF OFF OFF ON OFF 66 OFF ON OFF OFF OFF OFF ON OFF 67 ON ON OFF OFF OFF OFF ON OFF 68 OFF OFF ON OFF OFF OFF ON OFF 69 ON OFF ON OFF OFF OFF ON OFF 70 OFF ON ON OFF OFF OFF ON OFF 71 ON ON ON OFF OFF OFF ON OFF 1 3 2 Baudrate Settings The No 1 2 and 3 of SW2 switch are for setting the baudrate of the speed dome standing for 2400bps 4800bps and 9600bps respectively The baudrate will be set as 2400bps by default if it is out of this range Refer to the following table Table 1 3 Set the Baudrate of the Dome DIP Switch SW2 Baudrate Settings Baudrate Figure 1 2 3 2400 ON OFF OFF Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Sp
10. HIKVision IR Speed DOME PTZ Camera User Manual DS 2DF7274 A DS 2DF7276 A DS 2DF5284 A DS 2DF5284 A0DS 2DF5286 A DS 2DF5286 A DS 2DF7284 A DS 2AF7264 A DS 2AF7268 A IR Speed Dome Installation Manual V1 0 0 UD 6L0201A1032A02 Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Thank you for purchasing our product If there are any guestions or reguests please do not hesitate to contact the dealer This manual applies to IR Speed Dome This manual may contain several technical or printing errors and the content is subject to change without notice The updates will be added to the new version of this manual We will readily improve or update the products or procedures described in the manual DISCLAIMER STATEMENT Underwriters Laboratories Inc UL has not tested the performance or reliability of the security or signaling aspects of this product UL has only tested for fire shock or casualty hazards as outlined in UUs Standard s for Safety UL60950 1 UL Certification does not cover the performance or reliability of the security or signaling aspects of this product UL MAKES NO REPRESENTATIONS WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT 0203001030406 Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Regulatory Information
11. W1 Settings Address 1 2 3 4 5 6 7 8 Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual DIP Switch SW1 Settings 0 OFF OFF OFF OFF OFF OFF OFF OFF 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF 10 OFF ON OFF ON OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF 17 ON OFF OFF OFF ON OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF 19 ON ON OFF OFF ON OFF OFF OFF 20 OFF OFF ON OFF ON OFF OFF OFF 21 ON OFF ON OFF ON OFF OFF OFF 22 OFF ON ON OFF ON OFF OFF OFF 23 ON ON ON OFF ON OFF OFF OFF 24 OFF OFF OFF ON
12. all 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual 1 Drill four 8 holes in the ceiling according to the screw holes of the mounting base and then insert M8 expansion screws not supplied into the holes 2 Pull the power cable video cable and control wire through the cable hole of the mounting base 3 Attach the mounting base to the ceiling by aligning the screw holes of the mounting base with the expansion screws on the ceiling 4 Secure the mounting base by using nuts and washers to tighten the four expansion screws Figure 3 20 Install the Mounting Base Note Make sure that the cables are long enough For outdoor applications please apply waterproof measures between the ceiling surface and mounting base and around the cable hole The pendant mounting application is not recommended for places where the speed dome is easily caught in the rain 2 Install the pendant pole Steps 1 Pull out the cables through the pendant pole and screw the pendant pole into the mounting base 2 Secure the pendant pole and mounting base with the set screws Note For outdoor applications please apply the water proof thread compound to the threads ms Tv Figure 3 21 Ceiling Mount 3 Install the speed dome to the mount Please refer to Section 1 1 Installation and Cabling for installation details Lo
13. demands of system anti jamming and electrical safety both and it must not appear short circuit or mixed circuit with the zero conductor of strong grid When the system is grounded alone the resistance should be no more than 40 The sectional area of the grounding cable should be no less than 25mm2 For grounding instructions please refer to the Installation Manual of Speed Dome video arrester 1 communicate b lightning rod arrester porer arrester The speed dome should be in the range of 45 degrees under the lightning rod the resistance of earthing conductor should be smaller than 42 steel jacket Figure A 1 Lightning amp Surge Protection Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Grounding for Cement Pole Wall Installation When the speed dome is installed in environment where is relatively insulating to the earth e g cement pole or cement wall then only the control center reguires proper grounded locally Refer to the following figure Powe Display Power supply board Power supply board Video cable Control line Operating center Keyboard nar PS Ud Cement pole wall 1 5m underground Figure A 2 Grounding in Cement Pole Wall Installation Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Notes Because the signal t
14. e can be connected with alarm inputs O SVDC and alarm outputs Refer to the following diagrams for alarm output JQC 3FG Rela O Gb QUT y 10 A 250VAO Diagram left Diagram right Figure 1 7 Alarm Out Connections The alarm provides the relay output no voltage and the external power supply is required when it connects to the alarm device For DC power supply left diagram the input voltage must be no more than 30VDC 1A For AC power supply the external relay must be used right diagram to prevent damages to the speed dome and avoid risk of electric shock 1 5 Power Cable Requirement When the speed dome uses standard AC power supply the power cable should meet the demand The formula of the cross section S mm and the maximum transmission distance L m of the bare wire is as follows L 50 S analog speed dome L 40 S network speed dome Example For the analog speed dome the cross section of the cable is 1mm and the transmission distance is less than 50m According to the Appendix 5 24VAC Wire Gauge Standards for example the American wire gauge 18 the transmission distance should be 0 7854 50 39 27m Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Chapter 2 Mount Dimension Note Not all of the mounts are listed in this manual Please refer to the specification manual 2 1 Wall Mount You can use the wall mount with corner adapte
15. eeassesececeesesaeseeeesceeseaasaeeeeeceeees 39 Appendix 6 W ire Gatige Standards rere oerte eb erre eo areae Eve a ER e nhe e doveva ede kk Eae ED Md GYFF YRFA 40 Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Chapter 1 Installation Before you start Check the package contents and make sure that the device in the package is in good condition and all the assembly parts are included Note Do not drag the waterproof cables as shown in Figure 1 1 otherwise the waterproof performance is affected Figure 1 1 Do not Drag the Cables 1 1 Installing the IR Speed Dome Before you start Check the package contents and make sure that the device in the package is in good condition and all the assembly parts are included Please make sure the wall is strong enough to withstand more than 8 times the weight of the dome and the mount For cement wall you need to use the expansion screw to fix the mount The long arm wall mount is taken as the example for following mounting steps Steps 1 Remove the protective sticker from the dome drive Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Protective _ Sticker I Figure 1 2 Protective Sticker 2 Drill 4 screw holes in the wall according to the holes of the mount 3 Fix the wall mount to the wall with the M8 expansion screws Figure 1 3 Fi
16. eed Dome Installation Manual DIP Switch SW2 Baudrate Settings 4800 OFF ON OFF 9600 ON ON OFF 1 3 3 Protocol Settings The No 4 5 and 6 of SW2 switch are for setting the communication protocols of the dome Refer to the following table Table 1 4 Set the Protocol of the Dome DIP Switch SW2 Protocol Settings Protocol Figure 4 5 6 AD Manchester gt EXIT ON ON ON Others Self adaptive Notes The speed dome is self adaptive to PELCO D PELCO P and private protocol which cannot set by the DIP switches Network speed dome model does not support Manchester Code protocol 1 3 4 Communication Mode Settings The No 7 of SW2 switch is for setting the RS485 communication mode of the dome to simplex or half duplex Table 1 5 Set Communication Mode of the Dome DIP Switch SW2 Simplex Half duplex Settings Description Figure 7 Simplex OFF Half duplex sw OTT on 1 3 5 Terminal Resistor Settings The No 8 of SW2 switch is used for turning on off the 1200 terminal resistor Table 1 6 Set Terminal Resistor witch Number Description 8 Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Turn on the resistor OFF Turn off the resistor ON 1 4 Alarm Input and Output Connection The network speed dom
17. g iiit e et deed redet oa A BYNY eked eee etes vede bo Fn oed eaa ARR RNA OR VRAKET YF YY ede edes 19 3 2 Corner Mounting Applications 3 2 1 Components iiie ee th salsa diee dnte od da Pea ed eed ARR KRA NGA SKR de P e Ad oe dn en ed FE doa ed dide nna dig 3 2 2 Corn r MOUNTING AA elei een on eia e dude en no aa eio ee on n a e in ee ea n e aa e inia een on e a e n a n n ano ea e ea n c a e a n 21 3 3 Pole Mounting Applications s sssssisss ts ssssisteris serber ser sar eren ia enne E edsa LLA ALLAD DL LL sata tans FF FF 22 3 3 1 Components ud tie dele ee deinen en on deiade n n RA eine a e oae ed eeu aen no el eeu aen eo ade enu e eu an a een 22 3 3 2 Pole MOUNTING xod dS eines 24 3 4 Pendant MOUNti Ng Application 26 FAT CAM A e ete e exta dee exa exa ee rede een eain eux decd cake sae dae e een dn a ER aha e i dd C NR VAR 26 3 4 2 Pendan MoU O sicot oer epa cospeii ter diete ded eons di 26 AD PEN be DH HN 29 Appendix 1 Lightning amp Surge Protection ueeeeuuuui uir ILL LL LLI eene enne sr sens rss ks KR RK AR ARR RKA KR KR KR sas RR KR KR RR RR RK FFF ensi na 29 Appendix 2 Waterproof eau Et Ete Eee EUELLY FO 33 Appendix 3 Bubble Maintenance i oaee ate a a EE Rr EEE Ea Ea EEEE EERE E titan assesses tasas dass LLALL Eaa ss ss ensi na 35 Appendix 4 RS485 Bus COnneCtlOn iii er tete rt ee E NET e TERRE MER EE a Ee TETK 36 Appendix 5 24VAC Wire Gauge Transmission Distance cccccccccesssssscecccecseseaesecececees
18. ic interference situation or there are lots of devices are added to the bus on the contrary the transmission distance will be increased Connection Methods RS485 industry bus standard require daisy chain connection method between any devices both sides have to connect a 1200 terminal resistance show as Diagram 1 the simplified connection method is shown as diagram 2 but the distance of D should not be too long 1200 1200 14 2 3 4 32 Figure A 2 RS485 Connection 1 Controller 14 2 34 314 Figure A 3 RS485 Connection 2 O Problems in the Practical Application Normally users adopt star shape connection method in construction under this situation the terminal resistors must be connected between two farthest devices as Figure 4 1 and 154 but this connection method is not satisfy the reguirement of the RS485 industry standard so that it will lead to some problems such as signal reflection anti jamming ability decline when the devices are Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual faraway At this time the dome will be uncontrollable or self running etc For such case the best way is adding a RS485 distributor This product can effectively change the star shape connection to which satisfies the reguiremen
19. ions in your local region Please use the power adapter which is provided by normal company The standard of the power adapter is 24VAC 10 or 12VDC 10 depending on models The power consumption cannot be less than the required value Do not connect several devices to one power adapter as adapter overload may cause over heat or fire hazard Please make sure that the power has been disconnected before you wire install or dismantle the speed dome When the product is installed on wall or ceiling the device shall be firmly fixed If smoke odors or noise rise from the device turn off the power at once and unplug the power cable and then please contact the service center If the product does not work properly please contact your dealer or the nearest service center Never attempt to disassemble the speed dome yourself We shall not assume any responsibility for problems caused by unauthorized repair or maintenance A Cautions Do not drop the dome or subject it to physical shock and do not expose it to high electromagnetism radiation Avoid the equipment installation on vibrations surface or places subject to shock ignorance can cause equipment damage Do not place the dome in extremely hot cold dusty or damp locations otherwise fire or electrical shock will occur The operating temperature should be 30 C 65 C The dome cover for indoor use shall be kept from rain and moisture Exposing the equipment to direct sun light low
20. lier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see ERE www recyclethis info 2006 66 EC battery directive This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union See the product documentation for specific battery information The battery is marked with this symbol which may include lettering to indicate cadmium Cd lead Pb or mercury Hg For proper recycling return the battery to your supplier or to a designated collection point For more information see www recyclethis info Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Safety Instruction These instructions are intended to ensure that the user can use the product correctly to avoid danger or property loss The precaution measure is divided into Warnings and Cautions Warnings Serious injury or death may be caused if any of these warnings are neglected Cautions Injury or equipment damage may be caused if any of these cautions are neglected A A Warnings Follow these safeguards to Cautions Follow these precautions to prevent serious injury or death prevent potential injury or material damage A Warnings All the electronic operation should be strictly compliance with the electrical safety regulations fire prevention regulations and other related regulat
21. llow E Orange as E Lable 2 ORANGE RS485 YELLOW RS485 Figure 1 5 IR Speed Dome 1 3 DIP Switch Settings Two DIP switches SW1 and SW2 are for setting the speed dome address baudrate protocol etc with value ON 1 and OFF 0 The switch label is on the back of the SWITCH cover as shown in Figure 1 6 Each number of the switch represents a DIP value ranging from 1 to 8 for the lowest to highest Please refer to Section 1 3 1 to 1 3 2 for detailed settings Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Sw1 Number Rx eig 1 on EXT on Sva Address 255 r1 on on 6 aud on off off MG 4800 Baud rana RS 485 Figure 1 6 Label of DIP Switch Note The default dome address is 0 the default baudrate is 2400 and the default value of the 1200 terminator is OFF 1 3 1 Address Settings The SW1 switch is used for setting the address of speed dome You can refer to Table 1 1 and Table 1 2 for details of setting the speed dome address to a specific number Table 1 1 Set the Dome Address pome SW1 Settings 1l2 3 a 5 6 7 8 Address 8 0 s EEE orr off off OFF OFF OFF OFF orr 1 sw EIT on orr orrlorr orF OFF OFF orr 255 m LOTT lon on ON JON ON ON ON ON Refer to the following table for more address settings Table 1 2 Set the Dome Address from 0 to 71 DIP Switch S
22. nting hole on the mount For wooden wall you can just use the self tapping screw to fix the mount The wall must be thick enough to install the expansion screws Please make sure that the wall is strong enough to withstand more than 8 times the weight of the dome and the mount 3 1 Wall Mounting Applications 3 1 1 Components Wall Mount Figure 3 1 Wall Mount Mounting Accessories Figure 3 2 Nuts and Flat Washers Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual 3 1 2 Wall Mounting Steps 1 Drill 4 screw holes in the wall according to the holes of the mount and then insert M6 expansion screws not supplied into the mounting holes 2 Attach the gasket then wall mount to the wall by aligning the 4 screw holes of the mount with expansion screws on the wall 3 Secure the wall mount with 4 hex nuts and washers Figure 3 3 Drill Screw Holes 4 Install the speed dome to the mount Please refer to Section 1 1 Installation and Cabling for installation details Figure 3 4 Finish the Installation Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual 3 2 Corner Mounting Applications Before you start The corner mounting is applicable to the indoor outdoor 90 solid corner construction 3 2 1 Components Wall Mount
23. onnecting the Cables inicien Dn rer ER ERR ERROR EE TEGERE ER FF ERR e NAE FWA 8 1 3 DIP Switch Settlngs iu m i i e ee rr e EG Eee era veda FFF Ere ERE RF XR ERR Gy Fd dU ERE 1 3 1 Address Settings 1 3 2 Baudrate Settings 1 3 3 Protocol Settings se p E Dodo ONYDDU Y di NY 12 1 3 4 Communication Mode Settings nrasane sees nennen nh hn hannes sata a LEL LLAN easi nn DEN LEL NN sas sa daas sess essa sa dada 12 1 3 5 JTerminal Resistor Settings ice are no n ERU GREG REV DIAU CCD FLY DIAU 12 1 4 Alarm Input and Output Connection s srerersesrrrrrrssrsrrrrrrrrsserrrr rr errors rrr er rr sr nn AR ARR sister KR KRK RK KR KR RR RR KKR KR KR RR ense nenn 13 1 5 Power Cable Requirement sia side d r serna sol GG GWYR IO GR FR las re HERE AR DT 13 Chapter 2 Mount DIMENSION EE E 14 2 1 Wall MOULE x3 een de Sadie TE dyd nw a 22 Corner Adapter 23 Pol amp Adapter ae O ud TG Ge 16 2 4 Pendant Mot until eie oet erre estere GWGAN piede SIRE EE a E apes eva dese NND GYN GNWD COD 17 Chapter 3 Mounting ApplicatiOns ic ic0icesscecscccsiscicctiseciteestecieetisetsteeddesiccdisesiccedtesiceticedsdensiesiccdacesidecdtesicnticecicceaies 18 3 1 Wall Mounting Applications usmmssesesrsrreresserrsrrressorerrrrrsrrsrrr rr rs rss rr sr rr er ks SKAR ARR RAR RR KR RR KRK RR KR AR RBK RK RR KR RR RR RR RR KR KR RR RA RKA rs 18 3 1 1 COMP N OPUS GYD 18 3 1 2 Wall Mountin
24. ounting Steps 1 Assemble the pole adapter 1 Loosen the three pole mounting hoops with a screwdriver 2 Insert them through the rectangle holes of the pole adapter Figure 3 15 Assemble the Hoops and the Pole adapter 2 Install the pole adapter 1 Pull the control wire video cable and power cable through the center hole 2 Secure the three pole mounting hoops to the pole and tighten the screws of the hoops with a screwdriver Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Figure 3 16 Install the Pole Adapter Note For outdoor applications please adopt the water proof measures 3 Install the wall mount 1 Attach the gasket then wall mount to the pole adapter 2 Secure the wall mount to the pole adapter with 4 hex screws and the spring washers b a l 4 amp 3 Figure 3 17 Install the Wall Mount 4 Install the speed dome to the mount Please refer to Section 1 1 Installation and Cabling for installation details Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Dii Figure 3 18 Finish the Installation 3 4 Pendant Mounting Applications 3 4 1 Components Pendant Mount Figure 3 19 Pendant Mount 3 4 2 Pendant Mounting Steps 1 Install the mounting base Steps Lo C
25. r or pole adapter according to different installation environments 8 52 Figure 2 1 Wall Mount Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual 2 2 Corner Adapter A corner adapter has to be used together with a wall mount for corner mounting applications o 9 s ll 376 176 8 m BO amp E Lo Call 1890 866 900 4 R15 4 28 5 SN up S M 2 Figure 2 2 Corner Adapter www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual 2 3 Pole Adapter A pole adapter has to be used together with a wall mount for pole mounting applications 1 Q SS i I Nn oo lt t co 2 75 117 44 46 Figure 2 3 Pole Adapter Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual 2 4 Pendant Mount Figure 2 4 Pendant Mount Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Chapter 3 Mounting Applications Before you start For cement wall you need to use the expansion screw to fix the mount The mounting hole of the expansion pipe on the wall should align with the mou
26. ransmission media of fiber optical speed dome and network speed dome are isolated from the control center they must be grounded locally to protect dome against damages f the dome is installed in strong thunderstorm area it must be grounded locally to release lightening or suchlike high energy to protect dome against damages Refer to the following figure Powe Powe Power supply board Displa Power supply board Video cable Operating Center Keyboard u DVR Control line ut Cement pole wall 1 5m z 1 5m underground underground Figure A 3 Lightening protection Grounding in Cement Pole Wall Installation Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Grounding for Metal Pole Installation When the speed dome is installed in environment where is conductive to the earth e g metal pole then the grounding of dome can be achieved by the properly grounded metal pole meanwhile the control center must be grounded locally as well Refer to the following figure Powe Metal pole surface underground Power supply board Video cable Control line Display Operating Center Keyboard ENN 1 5m underground Figure A 4 Grounding in Metal Pole Installation Note If the fiber optics lightening protector or other device are applied during the transmission of speed dome such devices as well as the
27. t of RS485 industry standard in order to l 32 Controller Device 154 Figure A 4 Star Shape Connection avoid those problems and improve the communication reliability Show as figure 5 RS485 Distributor I 1200 I 1200 I 1200 164 Figure A 5 RS485 Distributor Troubleshooting of RS485 communication Problem Possible Reasons To Solve the Problem 1 Adjust the address and 1 The address or baudrate of the J baudrate of the remote control Thespeed speed dome does not match with device to match with those of the dome does those of remote control device T speed dome e 2 The wire RS485 connects to self test 2 Connect the wire RS485 to the the interface RS485 and wire i action but j interface RS485 and wire RS485 RS485 connects to the interface cannot be to the interface RS485 RS4854 controlled 3 The RS485 wire is 3 Reconnect the RS485 wire remotely 1 disconnected tightly 4 RS485 wire is broken 4 Change a RS485 wire The speed 1 The connection is loose 1 Reconnect the RS485 wire Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual
28. ventilation or heat source such as heater or Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual radiator is forbidden ignorance can cause fire danger Do not aim the speed dome at the sun or extra bright places A blooming or smear may occur otherwise which is not a malfunction however and affecting the endurance of sensor at the same time Please use the provided glove when open up the dome cover avoid direct contact with the dome cover because the acidic sweat of the fingers may erode the surface coating of the dome cover Please use a soft and dry cloth when clean inside and outside surfaces of the dome cover do not use alkaline detergents Do not stare at infrared LED closely to avoid hurting your eyes when the infrared lights are on Please keep all wrappers after unpack them for future use In case of any failure occurred you need to return the speed dome to the factory with the original wrapper Transportation without the original wrapper may result in damage on the speed dome and lead to additional costs Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Table of Contents Chapter 1 Hetaa O E MT 6 1 1 Installing the IR Speed Dome cceccccccccessesssececececseseeaesecececeesseaesesececeeseseesesecsceseesseaeseeeceseeseeaeseeeesseeseaaeaeseeecesses 6 1 2 G
29. video cables routing through must be proper grounded Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual Appendix 2 Waterproof Notes The long arm wall mount is recommended for the outdoor application of speed dome You cannot use the short arm wall mount or pendant mount for outdoor application because it is not water proof It is recommended to use the mount with inner threaded interface and good waterproof performance f you use a mount with outer threaded interface please adopt waterproof measures to the adapter applied between the mount and the dome Do not install indoor speed dome to the outdoor environment L shape Pole Mount Make sure that the L shape pole mount is designed with a certain inclination angle as shown in following figure Water won t flow from the pole into the speed dome with the inclination angle Figure A 5 Customized Mount Long arm Wall Mount The long arm wall mount is recommended for the outdoor application The arm of wall mount is designed with a certain inclination angle to prevent incoming water as shown in Figure A 6 During outdoor application the long arm wall mount can be used with the pole mount adapter or the corner mount adapter Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual 7 d Figure A
30. x the Mount 4 Install the speed dome to the mount 1 Hang the safety rope to the speed dome and then hook to the mount as shown in Figure 1 4 2 Route the cables of the speed dome through the wall mount 3 Connect the corresponding video power RS 485 cables 4 Loosen the two lock screws on the wall mount 5 Install the speed dome to the mount and secure the speed dome by rotating the speed dome clockwise 6 Fasten the two lock screws with the Allen wrench Lock Screw Lo Call 1890 866 900 www cctvireland ie shop cctvireland ie IR Speed Dome Installation Manual 1 2 Connecting the Cables Before you start Please make sure the power of the dome is off before connecting the cables Choose the video cable according to the transmission length The video should meet the least demands as 750 resistance 10096 copper core conducting wire 9596 weaving copper shield RS485 communication cable please refer to Appendix 4 24V AC power cable please refer to Appendix 5 The cable interfaces of speed dome are shown in the following figures Please refer to the following figure for connecting the RS 485 power and video cables As shown in the following figures the label instructs you to connect the power cables The label Q and G instruct you to connect the RS 485 cables Lable 1 RED AC24V YELLOW GREEN Black Min Yellow Green Red Ye
Download Pdf Manuals
Related Search
Related Contents
Interlab Member Laboratory User Manual Powerplus POWXG9020 high-pressure cleaner Samsung BT65FQBFST Bruksanvisning ARTM-9405 16x10GbE Installation and Use FPi 2000 OMR-Leitfaden für Programmierer - FP-IMS Copyright © All rights reserved.
Failed to retrieve file