1. wise to decrease STEP 3 Close the cylinder valve by turning the knob fully clockwise STEP 4 Partially engage a plug into one of the respirator connections while viewing the inlet pressure gauge As pressure drops to approximatley 500 PSI the low pressure whistle will begin to sound STEP 5 When test is complete open the regulator ON OFF valve REPLACEMENT PARTS TN SS A DESCRIPTION ASME RELIEF VALVE PRESET 125 PSI HANSEN COUPLING SCHRADER COUPLING HANSEN DUST CAP SCHRADER DUST CAP OUTLET PRESSURE GAUGE PRESSURE REGULATOR NO GAUGES 6 INLET PRESSURE GAUGE a LEDER VALVE woo o poo CGA 346 347HANDTIGHT SS347HT WHIP ASSEMBLY 1 4 MPT X 1 4 FPT NOTES WARRANTY DISCLAIMER Air Systems manufactured equipment is warranted to the original user against defects in workmanship or ma terials under normal use for one year from the date of purchase Any part which is determined by Air Systems to be defective in material or workmanship will be as the exclusive remedy repaired or replaced at Air Sys tems option This warranty does not apply to electrical systems or electronic components Electrical parts are warranted to the original user for 90 days from the date of sale During the warranty period electrical com ponents will be repaired or replaced at Air System
2. Manual No PAKO14 Rev 2 August 2013 INTERNATIONAL OPERATING MANUAL MODELS MP 2300ENB AND MP 2300ECY AIR SYSTEMS INTERNATIONAL INC 829 Juniper Crescent Chesapeake Va 23320 Telephone 757 424 3967 Toll Free 1 800 866 8100 Fax No 757 424 5348 http www airsystems com e mail sales airsystems com SPECIFICATIONS 48H x 25 W x 31 D Weight w o cylinders 5000 PSI Rated Thermo Plastic Hose with a 4 1 Whip Assemblies Safety Factor Low Pressure Whistle Set approximately 500 PSI Relief Valve ASME preset 0 125 PSI Intrinsically Safe irder 2 444 cu ft 4500 PSI cylinders P N AC 444 included with Model MP 2300ECY only Check Valves Stainless Steel 1 per Whip Assembly DE sue 5500 PSI Max Inlet Pressure 125 PSI Max Outlet Pressure SET UP OPERATION CGA 346 347 HAND TIGHT BLEEDER VALVE LOW PRESSURE a amp PRESSURE REGULATOR A RESPIRATOR CONNECTIONS VA A STEP 1 Place cylinders on cart and secure by tightening straps at the buckle Mate the hook and loop sections to prevent slipping STEP 2 Install the CGA 346 347 universal hand tight nuts to the cylinder valves and tig
3. hten Close the bleeder valves by turning knobs clockwise STEP 3 Open cylinder valve s Whistle will sound until approximately 1000 PSI STEP 4 Adjust regulator to desired output pressure by turning regulator knob clockwise to increase pressure or coun terclockwise to decrease STEP 5 Connect hose s and respirator s to the respirator connections STEP 6 Readjust pressure regulator if necessary Note The whip assemblies are equipped with check valves that prevent backflow from the opposing cylinder This also allows a cylinder to be replaced while the other cylinder is in use so workers can continue their duties uninterrupted LOW PRESSURE ALARM TEST LOW PRESSURE wU s lt INLET PRESSURE GAUGE PRESSURE REGULATOR RESPIRATOR CONNECTIONS STEP 1 Open one cylinder valve STEP 2 Set the required outlet pressure by turning the regulator knob clockwise to increase pressure or counterclock
4. oll Free 1 800 866 8100 Fax No 757 424 5348 http www airsystems com e mail sales airsystems com Printed in the U S A Copyright Air Systems International Inc 2013 All Rights Reserved
5. s option NO OTHER WARRANTY EXPRESSED OR IMPLIED AS TO DESCRIPTION QUALITY MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER MATTER IS GIVEN BY AIR SYSTEMS IN CONNECTION HERE WITH UNDER NO CIRCUMSTANCES SHALL THE SELLER BE LIABLE FOR LOSS OF PROFITS ANY OTHER DIRECT OR INDIRECT COSTS EXPENSES LOSSES OR DAMAGES ARISING OUT OF DEFECTS IN OR FAILURE OF THE PRODUCT OR ANY PART THEREOF The purchaser shall be solely responsible for compliance with all applicable Federal State and Local OSHA and or MSHA requirements Although Air Systems International believes that its products if operated and maintained as shipped from the factory and in accordance with our operations manual conform to OSHA and or MSHA requirements there are no implied or expressed warranties of such compliance extending beyond the limited warranty described herein Product designs and specifications are subject to change without notice Rev 2 12 98 Air leaks are not covered under warranty except when they result from a defective system component e an on off valve or regulator or upon initial delivery due to poor workmanship Air leaks due to poor delivery or damage will be covered under delivery claims Minor air leaks are part of routine service and maintenance and are the responsibility of the customer just as are filters and oil changes AIR SYSTEMS INTERNATIONAL INC 829 Juniper Crescent Chesapeake Va 23320 Telephone 757 424 3967 T