Home
User Manual Magnetic paint
Contents
1. at least 2 coats to make the base suitable for magnets Finish if required with any colour wall paint or paper For interior use only Item number Finish Colour range Solids content Density 394R 3457777 Matt Grey approx 84 w approx 58 vol approx 2 57 kg dm3 at 20 C Drying time 20 C 65 r h Dust dry With wet coat thickness 100 um Completely dry Ready for painting after around 1 hr dry to touch after around 2 hours after around 3 hr after at least 4 hours after maximum unlimited Flame point DIN 53213 non flammable Application data Ambient conditions room temperature between 15 and 25 C Relative humidity between 40 and 70 R H Thinners for changing viscosity water To clean equipment water Forced drying not applicable Recommended thickness per coat dry 58 um wet 100 um Theoretical coverage around 10 m2 It for 58 um dry Practical coverage The practical coverage depends on the application method the quality of the base and the shape of the object Features stir well before use the Step 1 The surface to be painted with magnetic paint should be smooth Do not apply the paint to damp surfaces such as fresh plaster or wet rooms Mask off the sur face to be painted and stir the paint well before use Never dilute the magnetic paint with water or other latex Cover the surrounding area against splashes and drips Step 2 Apply the paint with a fleece roller to get a
2. good layer thickness Spread the paint well to ensure an even magnetic attraction force Apply two or more coats company The more coats you apply the stronger the magnets will adhere Test the magnetic force of the wall after the second coat and if necessary apply a third coat Do not sand down the painted surface the iron par ticles will come to the surface and no longer be pro tected by the paint Cover the roller and tray while you wait and wrap the roller in a plastic bag to prevent drying out the Step 3 Allow each coat to dry for at least 4 hours to ensure that the next coat will adhere properly to the base If the base is not absorbent e g a door double the drying time On unstable bases first apply a water based primer to prevent flaking Step 4 After 24 hours you can paint over the magnetic paint with a water based paint in any colour company If the background is unstable double the drying time here too We advise you to use a water based eggshell or wall paint as a top coat This is stronger washable and gives better protection against damage to the base If you choose another finish contact us first for technical advice Step 5 The wall is ready for use If you choose a different colour later first apply a new coat of magnetic paint C the company Projects The Magnetic Company can offer you assistance on projects As an architect or decorator do you have any quest
3. A PROFESSIONAL DURLIT pomt PROFESSIONAL QUALTY Supplier The Magnetic Company office Julianastraat 30 2012 ES Haarlem Telefoon 31 0 23 7114545 Email office themagneticcompany nl Further information www themagneticcompany com Wa p rs nt fo r m d o n ets C the company The Magnetic Company The Magnetic Company is an enthusiastic company which is the first in Europe to introduce magnetic paint After a long preparation period we are now manufacturing magnetic paint in collaboration with UP Quality and Environment Netherlands This paint has been subjected to various tests by leading professionals and the results are astounding Magnetic paint is a grey water based paint which contains iron particles to attract magnets Thanks to our paint you can work actively with your wall without any signs showing on the wall The product offers great new potential which we will sketch out for you as far as possible in this leaflet Inspiration Magnetic paint can be used for many purposes To give you an idea here are some applications Child s bedroom after painting with blackboard paint and a combination of blackboard magnetic paint Office handy as a message or display board with no more damage to the wall from sticky tape etc Office after painting with whiteboard paint and a combination of whiteboard magnetic paint Canteen change menus easily Classrooms no more sticky tape or drawing pins on
4. c material After contact all parts of the body should be washed Toxicological information On respiration eye contact in high concentrations irritation of mucous membranes sedative effect and reduction in reaction capacity and co ordination are possible After sustained respiration of high vapour concentrations headache dizziness nausea etc can occur Delayed occurrence of problems possible breathing coughing asthma On eye contact irritation the toxicological classification of the product was performed on the basis of the results of the calcula tion method in the general separation guidelines 88 379 EEC Exposure to combined vapours of solvent in concentrations higher than the given maximum exposure can damage health for example irritation of mucous membrane and respiratory organs and can have a harmful effect on the kidneys liver and central nervous system Symptoms include headaches dizziness fatigue muscle weakness sleepiness and in extreme cases loss of consciousness Absorption of solvents through the skin can cause some of the above symptoms Repeated or sustained exposure to the product can result in the loss of grease from the skin which can result in non allergic contact eczema The product can be absorbed through the skin If the fluid enters the eyes it can cause irritation and irreparable damage Ecological information Additional ecological information General information Do not allow to enter water or the drainage s
5. ions about Magnetic Paint or Whiteboard paint We will be pleased to put our know ledge at your disposal in the form of good technical advice We do this in close collaboration with the technical staff of UP Quality amp Environment and the wholesale trade You can contact us via our email office themagneticcompany nl Safety information Product name and data on company Commercial name MAGNETIC PAINT Wallpaint for magnets Recommended application As wall paint for magnets and magnetic materials in professional decorating trade Manufacturer supplier Up Quality and Environment BV Road PO box Dokweg 40 Country code Postcode Place NL 1976 CA IJmuiden The Netherlands Phone Fax 31 0 255 548448 31 0 255 588445 exclusively for treating doctor in case of intoxification 31 0 30 2748888 National Poisons Information Centre C the company Summary and information on components Hazardous constituents First aid measures general information In case of doubt or if symptoms persist consult a doctor Never place anything in or block the mouth of an unconscious person Bring the person into the fresh air keep warm Allow the patient to rest On irregular or lack of respiration artificial respira tion On loss of consciousness place on one side and call doctor immediately remove contaminated clothing Wash thoroughly with soap and water and rinse well Do not use any solvents or thinners remove contact lenses Keep eye
6. lids open Rinse with plenty of water 10 15 minutes consult a doctor immediately Allow the patient to rest Do not induce vomiting Measures on accidental release of substance or product Remove sources of combustion Ensure good ventilation Do not breathe vapours Follow the protec tive measures do not pour down drain If the product contaminates streams rivers or drains inform the authorities in accordance with the local regulations contain spillage and absorb in a non flammable material such as sand earth silica gel or vermiculite and store in a container for processing according to local regulations Preferably clean with a cleaning agent avoid the use of solvents Measures to control exposure personal protection ensure adequate ventilation Where possible this must be achieved using local air extraction and good room ventilation If these are not sufficient to keep the concentration of particles and vapour from solvents below the MAC values appropriate breathing protection must be worn Personal protection equipment if workplace limit values are exceeded wear respiratory equipment suitable for the purpose For spray applications fresh air mask Other application methods only use in well ventilated rooms Instead of a fresh air mask a face mask with combination filter can be used wear safety gloves resistant to solvent wear safety goggles staff must wear anti static clothing of natural material or heat resistant syntheti
7. the wall children can hang their drawings safely Kitchens ideal as a message board for shopping lists and recipes Shops for offers displays and promotions Meeting rooms presentations are easier and more complete Exhibition stands no more holes in your stand displays can be changed quickly C the company Instructions for use Before use STIR the paint WELL to distribute the metal particles evenly Do NOT DILUTE or MIX the paint with other paint or water Magnetic paint can only be used indoors in a dry environment If you want the option of being able to remove the paint later first paper the wall A smooth base gives the best results If you want to apply a magnetic paint to a door first apply a water based primer Prepare the surface to be painted as you would for normal wall paint Apply two or more coats with a fleece roller Leave the paint to dry for four hours after each coat The more coats you apply the better the magnets will adhere One liter will cover around 2 to 2 5 m2 in a minimum of two coats After 24 hours you can apply any water based wall paint in any colour Remove drips with a damp cloth Clean your brush with water and soap Important carefully close the pot after use Keep the paint out of the reach of children and protect from frost Technical information Description Wall paint based on acrylate dispersion Use As wall paint in the professional decorating industry Application Apply
8. ystem Instructions for disposal recommendation contaminated packs should be emptied fully After being cleaned they can be recycled Uncleaned packs should be treated as waste Other information the data in this safety document complies with national and EC legislation The user s working conditions are however beyond our knowledge or control The product may not be used for purposes other than those listed under section 1 without written consent The user is responsible for observing all necessary legal conditions This information is based on the present state of knowledge It does not however give any guarantee of product properties or establish any contractual rights
Download Pdf Manuals
Related Search
Related Contents
FuSioN User Guide Active Holding *2068386* 2068386 Índice Installation and Operating Instructions Copyright © All rights reserved.
Failed to retrieve file